Home

GE SPACEMAKER DSKS333EC User's Manual

image

Contents

1. at work 25 1 4 gt gt 2 1 2 ry 0 16 1 4 lt 47 gt A o a A CA Gas supply Vent gt 9 3 8 lt pipe rear J rear w 54 5 16 lonly lt w A Water inlets 5 1 4 rear 8 75 1 2 43 gt 4 13 16 igi 41 1 4 36 1 16 i rain outle 29 716 6 reat o A 3 3 4 11 7 16 yy peres e AR y y Hoti 30 13 16 gt a 27 Power Cord Location Power Cord Hole Back View Listed by Underwriters Laboratories UL Specification Revised 5 09 360326 WSM2700 80H GE 27 Unitized Soacemaker Washer and Dryer Dimensions and Installation Information in inches Best performance Maximum length of 4 dia rigid metal duct 4 Exhaust hood type B Number of A B Domestic 2 1 2 90 4 2 1 2 dryer models turns opening DSKS433EB DSKS333EC DSKP333EC WSM2780H WSM2700H WSM2420D WSM2480D For answers to your Monogram GE Profile or GE appliance questions visit our website at ge com or call GE Answer Center service 800 626 2000 imagination at work For complete information see installation instructions packed with your dryer Ducting Materials For best performance this dryer should be vented with 4 diameter all rigid metal exhaust duct If rigid metal duct cannot be used then UL listed flexible metal semi r
2. WSM2700 80H GE 27 Unitized Soacemaker Washer and Dryer Dimensions and Installation Information in inches Electrical Requirements WSM2700H Electric Dryer This appliance should be connected to an individual properly grounded branch circuit with 120 240V or 120 208V single phase 60 Hz electrical service and should be protected by 30 amp time delay fuses or circuit breakers KW Rating per voltage 240 208 This appliance is manufactured with neutral connected to the frame Power cord should be purchased separately Note These appliances are not approved for 120 volt operation Gas Requirements WSM2780H Gas Dryer This appliance should be connected to an individual branch circuit with 120 volt single phase 60 Hz electrical service and should be protected by 20 amp time day fuses or circuit breakers This appliance is equipped with a 4 foot long flexible U S listed 20 amp power cord to match a 20 amp receptacle Note Gas Rated input 20 000 BTU HR Factory equipped for natural gas Tested for LP gas LP gas supply requires a conversion kit Have a qualified gas technician install a conversion kit before use Dryers must be exhausted to the outside Installation Information For complete information see installation instructions packed with the product For answers to your Monogram GE Profile or GE appliance questions visit our website at ge com or call GE Answer Center service 800 626 2000 imagination
3. igid ducting can be used Kit WX08X10077 In special installa tions it may be necessary to connect the dryer to the house vent using a flexible metal foil type duct A UL listed flexible metal foil type duct may be used ONLY in installations where rigid metal or flexible metal semi rigid duct ing cannot be used AND where a 4 diameter can be maintained throughout the entire length of the transition duct Please see installation instruction packed with your dryer for complete instructions when using flexible metal foil type ducting Exhaust Length Calculation 1 Determine the number of 90 turns needed for your installation If you exhaust to the side or bottom of dryer add one turn 2 The maximum length of 4 rigid aluminum or galvanized duct which can be tolerated is shown in the table A turn of 45 or less may be ignored Two 45 turns within the duct length should be treated as a 90 elbow A turn over 45 should be treated as a 90 elbow Dryers must be exhausted to the outside Caution For personal safety do not terminate exhaust into a chimney under any enclosed house floor crawl space or into an attic since the accumulated lint could create a fire hazard or moisture could cause damage Never terminate the exhaust into a common duct or plenum with a kitchen exhaust since the combination of lint and grease could create a fire hazard Exhaust ducts should be terminated in a dampered wall cap to prevent back d
4. rafts bird nesting etc The wall cap must also be located at least 12 above the ground or any other obstruction with the opening pointed down Special Installation Requirements Alcove or Closet Installation e If your dryer is approved for installation in an alcove or closet it will be stated on a label on the dryer back e The dryer MUST be exhausted to the outside e Minimum clearances between dryer cabinet and adjacent walls or other surfaces are 0 either side and rear 1 front and top e Minimum vertical space from floor to overhead cabinets ceilings etc is 52 e Closet doors must be louvered or otherwise ventilated and must contain a minimum of 60 sq in of open area equally distributed If this closet contains both a washer and a dryer doors must contain a minimum of 120 sq in of open area equally distributed e No other fuel burning appliance shall be installed in the same closet with a gas dryer Bathroom or Bedroom Installation e The dryer MUST be exhausted to the outdoors e The installation must conform with the local codes or in the absence of local codes with the National Electric Code and National Fuel Gas Code ANSI Z223 for gas dryers Minimum Clearances other than Alcove or Closet Installation e Minimum clearances to combustible surfaces U ieee 0 either side and rear L Laboratories 1 front and top Specification Revised 5 09 360326 WSM2700 80H GE 27 Unitized Soacemaker Washer and Dryer Fea
5. tures and Benefits e 2 7 cu ft extra large capacity e One Wash Spin Speed Matches wash action to fabric type for better cleaning and clothes care e Three Wash Cycles A cycle for almost every fabric from cottons to delicates e Three Wash Rinse Temperatures Allow you to select the right temperature for better wash results and long fabric life e Three Water Levels Minimize water waste allowing you to select water level based on load size e Electromechanical Controls Selector Knob turns smoothly in either direction simplifying cycle selection e Model WSM2700HWW White on white Electric e Model WSM2780HWW White on white Gas 96 imagination at work Specification Revised 5 09 360326

Download Pdf Manuals

image

Related Search

Related Contents

PDF (39k/8ページ) - コダック  X64-AN Quad User's Manual    DELUXE 16 INCE  Descargar documento con más información  公開研究会まであと10日  CoExDB  

Copyright © All rights reserved.
Failed to retrieve file