Home
GE RV60 Installation Guide
Contents
1. gt A WARNING AVERTISSEMENT Risk of electrical shock Ensure that all connection points are sealed for damp location using the appropriate method per the NEC or local electrical code Risque de choc lectrique S assurer que les points de raccordements sont scell s pour emplacement humide en employant une m thode permise par le NEC ou par le code lectrique local Connection Configurations Multiple LED Light s electrical input should be in parallel connection to an LED driver s output as shown by the example wiring diagram below Refer to Maximum LED Driver Loading table to determine maximum number of LED lights per LED driver One End Set Right and Left amp One Center LED Light SWITCH Note LED Lights are polarity insensitive v Driver Wire Connector Cavities 39 01 4030 AC Cavity 1 Line 1 Black Cavity 2 Earth Ground Green Cavity 3 Neutral or Line 2 White 39 01 4046 DC Cavity 1 Output DC Red Cavity 2 Output DC Black i LED DRIVER iP ds Cavity 3 Dimming Purple S Cavity 4 Dimming Gray G Gray Purple OO Occupancy Sensor WHITE NEUTRAL Terminal Block AC Source BLACK LINE RIGHT END LED LIGHT LEFT END LED LIGHT CENTER LED LIGHT For information on A B C D see Steps 4 5 and 6 Connect LED Driver Output e For retrofit place LED driver in the location where the ballast was formerly located e Make output DC conn
2. installation Contactez un lectricien qualifi Installez ce kit seulement dans les luminaires qui ont les caract ristiques de construction et les dimensions figurant sur les photographies et ou des dessins Remove Existing Lighting Components Tools Required Components Required Area Ge q Q Wire stripper cutter LED light Tape measure LED driver Screwdriver Wire cover Cordless drill Hammer 7 64 inch 2 8mm drill bit Center punch 6 32 x 1 2 screws Twist lock splice wire connectors OO00 6 For retrofit only If you are an OEM please refer to the OEM Fluorescent Com ponent Location Installation Guide Refer to manufacturing manual for refrigeration case to identify lighting control circuits Ensure that power is switched off at the service panel for the lighting circuit If a lighting power switch is not provided in the refrigeration case power removal can be performed at the main breaker panel Locate existing lighting components including ballasts lampholders lamps and lampguards in the refrigeration case for removal Please refer to refrigeration manual for any questions dealing with component locations Remove lamps lampholder and lamp guards Cut the wiring making the cut as close to the lampholder as possible Do not remove wiring from case as it will be utilized to attach the LED light Dispose of components per federal and local regulations Locate ballast wit
3. second screw and for the bottom of the End LED Light e Refer to the manufacturing manual for door frame to ensure there are no components contained inside the mullion that could be drilled through Use a 6 3 4 inch self drilling screw to attach the End LED Light into one or two of the additional mounting holes located near the center of the LED Light e Refer to wiring diagram on page 6 Connect the red and black output wires from the LED Light to the red and black wires on the l l Mounting Tab LED Driver using the twist lock splice wire connectors provided CAUTION ATTENTION Risk of injury Do not overload LED Driver Do not exceed limits shown in Maximum LED Driver Loading table below Risque de blessure Ne pas surcharger l alimentation Ne pas ex der les limites de la table ci dessous Charges maximales pour les alimentations LED Driver Configuration Options Both 50 watt and 100 watt LED Drivers are available for a variety of case configurations Maximum LED Driver Loading 50W Driver 100W Driver 6 Door 5 Door 4 Door 3 Door 2 Door 60 inch LED Lights 3 Center 1 End 7 Center 67 inch LED Lights 3 Center 6 Center 48 inch LED Lights 4 Center 8 Center 1 Center may be substituted by 2 End LED lights Parts Needed Per Case Center LED Lights End LED Light Sets Wire Covers Using 50W LED Drivers Using 100W LED Drivers ji LED Drivers 48 inch LED Lights e e E
4. Retrofit Installation Guide GE Lighting IMMERSION LED Refrigerated Display Lighting Vertical Cases RV60 Series End Mullion LED Lights 48 inch GELT604850EDR SY SB 85743 85746 GELT604850EDL SY SB 85744 85747 GELT604840EDR SY SB 85749 85752 GELT604840EDL SY SB 85750 85753 GELT604835EDR SY SB 85755 85758 GELT604835EDL SY SB 85756 85759 60 inch GELT606050EDR SY SB 85700 85703 GELT606050EDL SY SB 85701 85704 GELT606040EDR SY SB 85706 85709 GELT606040EDL SY SB 85707 85710 GELT606035EDR SY SB 85712 85715 GELT606035EDL SY SB 85713 85716 67 inch GELT606750EDR SY SB 85720 85723 GELT606750EDL SY SB 85721 85724 GELT606740EDR SY SB 85726 85734 GELT606740EDL SY SB 85727 85735 GELT606735EDR SY SB 85737 85740 GELT606735EDL SY SB 85738 85741 Description Code Single Unit Product Number 10 Pack Product Number BEFORE YOU BEGIN Read these instructions completely and carefully FOR YOUR SAFETY Read and observe all CAUTIONS and WARNINGS shown throughout these instructions e Installation to be performed by factory trained service personnel only e For use inside a commercial refrigeration case with packaged foods only e Use this unit only in the manner intended by the manufacturer If you have any questions contact the manufacturer e Before installing servicing or cleaning unit switch power off at the service panel and follow appropriate lock out tag out s
5. afety procedures LED DRIVER COMPATIBILITY This system is compatible with GEPS6000NCMUL SY or GEPS6500NCMUL SY LED Driver Please refer to the separate LED driver installation guide for appropriate wiring connections This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation NOTE This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense imagination at work PREPARE ELECTRICAL WIRING Electrical Requirements e The power supply must be supplied with 100 240 VAC 50 60 Hz and connected to an individual properly grounded branch circuit protected by a 15 or 20 ampere circuit breaker or time delay fuse e Wiring must be 2 wire w
6. bjets tranchants Prepare for Installation of End LED Lights e Measure 1 3 32 inches 28 mm from the edge of the mullion Left End Shield Right End Shield nearest the door and mark a vertical line near the top and T aL bottom of the frame mullion LED Driver Leads ft e Prepare for the upper end of the End LED Light Mark a 2 1 8 54 mm horizontal line a minimum 2 1 8 inches 54 mm from the top E of the door opening and another horizontal line 3 8 inches 3 8 10 mm 10 mm below this line e Prepare for the lower end of the End LED Light For 48 inch LED Lights mark a horizontal line 46 1 4 1175mm beneath the first line drawn for For 48 inch LED Lights the top Mounting Tab 46 1 4 1175mm For 60 inch LED Lights mark a horizontal line For 60 inch LED Lights 58 3 32 1476mm beneath the first line drawn for 58 3 32 1476mm the top Mounting Tab For 67 inch LED Lights For 67 inch LED Lights mark a horizontal line 65 15 32 1663mm 65 15 32 1663mm beneath the first line drawn for the top Mounting Tab Center punch at intersection Then mark another line 3 8 inches 10 mm below this line and drill a 7 64 inch 2 8 mm e Center the center punch directly at the intersection of the hole 3 8 10 mm horizontal lines and the vertical line top and bottom and establish a dimple are End Mullion Left End Mullion Right e Use power drill and 7 64 inch 2 8 mm drill bit to drill j holes at the intersectio
7. ections using one of the two options below USING TWIST ON WIRE CONNECTORS Remove the 4 way connector from the LED Driver by For non dimming applications cap the unused wires cutting the wires near the connector and strip the output with 5 32 4mm twist on wire connectors leads Using the appropriate wiring diagram on page 5 connect the LED Driver output leads to the LED Light leads Bundle and safely secure any unused wires by way of Use an ohm meter to identify the two wires connected to the approved wire ties and wire connectors LED Light that measure between 15 000 18 000 ohms Use wire connectors or other connection method approved for low temperature usage and stranded cable A Connect LED Driver Input e Make input AC connections as noted below USING TWIST ON WIRE CONNECTOR the appropriate wiring diagram on page 5 connect the The LED Driver is required to be reliably bonded to the original Line and neutral wires or Line 1 and Line 2 protective ground conductor wires for 240 nominal VAC to the LED Driver leads using Attach the supplied green yellow ground wire from the the provided twist lock splice wire connectors or other LED Driver to a grounded metal portion of the door frame connection method approved for low temperature Remove the 3 way connector from the LED Driver by cutting usage and stranded cable C the wires near the connector and strip the input wires Using Connect Dimming Contacts Output Optiona
8. hin system The most common location is in the mullion or the electrical raceway found in the bottom of the refrigerated case Lamp with lamp guards behind mullion Lamp holders Disconnect ballast input and output connectors Cut the ballast connector wires nearest to the connector and remove Ballast connector Unscrew the mounting screws that attach ballast Keen and remove ballast Dispose of ballasts according to federal a e 3 Overhead door frame and local regulations LED driver installation will begin at Step 5 and Step 6 Q To install the LED light first identify the wiring for connection to the LED driver After removing the connector from ballast leave the existing ballast input and output wires for reconnection in a later step A WARNING AVERTISSEMENT Risk of fire or electric shock Luminaire wiring and electrical parts may be damaged when drilling for installation of LED retrofit kit Check for enclosed wiring and components Risque de feu ou lectrocution Les pi ces et c bles lectriques risquent d tre endommag s lors du per age des trous pour l installation du luminaire DEL Veuillez v rifier si des cables et composantes se trouvent derri re la paroi avant de percer To prevent wiring damage or abrasion do not expose wiring to edges of sheet metal or other sharp objects Pour viter l endommagement de c blage ou l abrasion ne pas exposer le c blage aux bords de feuilles de m tal ou d autres o
9. ith ground and rated for 75 C 167 F e Do not overload driver follow installation instructions for the GEPS6000NCMUL SY or GEPS6500NCMUL SY e Ensure that all connection points are sealed for damp location using the appropriate method per the NEC or local electrical code Grounding Instructions Cable Direct e This lighting system must be connected to a grounded metal permanent wiring system or an equipment grounding conductor must be run with the circuit conductors and be connected to the equipment grounding terminal A CAUTION ATTENTION Risk of injury While performing installations described gloves safety glasses or goggles should be worn Risque de blessure Lors de l ex cution des installations d crites des gants des lunettes de s curit ou des lunettes de protection doivent tre port es AXAWARNING AVERTISSEMENT Risk of electrical shock Disconnect power before servicing or installing product LED Retrofit Kit Installation requires knowledge of luminaires electrical systems If not qualified do not attempt installation Contact a qualified electrician Install this kit only in the luminaires that have the construction features and dimensions shown in the photographs and or drawings Risque de choc lectrique Couper le courant avant de r parer ou installer le produit LED Retrofit Kit d installation n cessite la connaissance des syst mes luminaires lectriques Si vous n tes pas qualifi ne tentez pas l
10. l e To enable dimming operation connect leads from occupancy sensor or control system normally open contact to the purple and gray leads of the power supply Other methods such as using occupancy sensors to switch the LED driver on and off is not recommended and will void the product warranty e Make output contact closure connections using one of the two options below USING TWIST ON WIRE CONNECTORS Remove the 4 way connector from the LED Driver by cutting the wires near the connector and strip the output leads Using the appropriate wiring diagram on page 5 connect the LED Driver dimming output leads to the occupancy sensor or control system using wire connectors or other connection method approved for low temperature usage and stranded cable e The GEPS6000NCMUL SY or GEPS6500NCMUL SY LED Driver is capable of step dimming from 100 power to 20 power when used with a normally open contact closure occupancy sensor system e When using the GEPS6000NCMUL SY or GEPS6500NCMUL SY for dimming applications the slider switch setting must be set to the right to disable the dimming feature and achieve 100 illumination Dimming Enabled 20 oman O I ZO Se 5 A CAUTION ATTENTION Risk of electrical shock Plastic cover is needed to protect electrical wires from tampering and accidental contact Risque de choc lectrique Le couvercle en plastique est requis pour assurer une protection ad quate contre l acc s aux fils et
11. les contacts accidentels Attach Covers to End Cap Wire Cover e Tuck wires underneath Wire Cover before placing it over the End Cap and Mounting Tab e Attach Wire Cover to LED Light End Cap by installing a tie pan M2 9x10 pan head tapping screw provided through the n hole in the End Cap and Mounting Tab using an installation torque of 3 Ibf in NOTE Tighten slowly until fully seated do not over tighten or End Cap strip the threads e Repeat these steps for the mullion on the other end of the case A WARNING AVERTISSEMENT Risk of electrical shock Disconnect power to LED Lights before any cleaning operation Risque de choc lectrique D branchez l alimentation des clairages LED avant toute op ration de nettoyage LED Refrigerated Display Lights Cleaning Instructions e The outer lens and the plastic housing should be cleaned e Do not wipe the lens with a soiled dish cloth or wet towel periodically with a mild liquid dish detergent These may leave a residue that can damage the finish e Do not use chemical cleaners to clean the lens e Do not use scouring pads powdered cleaners bleach or cleaners containing bleach because these products can e Keep the outside clean Wipe with a clean cloth lightly A ne anien dampened with mild liquid dish detergent Dry with a clean soft cloth This product is intended solely for the use of commercial refrigerated display or case lighting and is not intended f
12. n of the vertical center line and the horizontal lines e Repeat these steps for the mullion on the other end of the case View from inside case looking out Identify End LED Light Right from Left e Verify LEDs are directed towards the center of the case before installing NOTE Installing the LED Light on the wrong side will result in very low light level inside the refrigerated case View from inside case looking out A WARNING AVERTISSEMENT Risk of electrical shock Only those open holes indicated in the photographs and or drawings may be made or altered as a result of kit installation Do not leave any other open holes in an enclosure of wiring or electric components Risque de choc lectrique Seuls les trous ouverts indiqu s dans les photos et ou les dessins peuvent tre faites ou modifi s a la suite du montage du kit Ne pas laisser autres trous ouverts dans l enceinte du c blage lectrique ou composants Install End LED Lights e Place proper End LED Light against the face of the mullion near the two holes drilled at the top NOTE Refer to proper End LED Light orientation depicted in Step 2B LED Driver Output Leads End LED Light Power Leads e Insert a 6 32 x 1 2 inch sheet metal screw into the slot of the Mounting Tab on the End LED Light and into the first hole that was drilled in the end mullion e Use a screwdriver to start threading the screw into the drilled hole e Repeat for the
13. or use in any other application GE Lighting Solutions e 1 888 MY GE LED 1 888 69 43 533 www gelighting com GE Lighting Solutions LLC is a subsidiary of the General Electric Company Immersion is a trademark of GE Lighting The GE brand and logo are trademarks of the General Electric Companu Information provided is subject to change without notice All values are design or typical values when measured under laboratory conditions 2013 GE 64140 121013
Download Pdf Manuals
Related Search
Related Contents
BEHR 00901 Installation Guide Samsung BCD-220MMSW-C 用户手册 I11 User Manual - Diamond Light Source 181~186ページ Copyright © All rights reserved.