1. switch as shown below OPTION 1 OEM USING 3 WAY CONNECTOR Attach the supplied green yellow ground wire from the LED Driver to a grounded metal portion of the door frame Connect the original Line and neutral wires or Line 1 and Line 2 wires for 240 nominal VAC to the 3 way connector for the LED Driver input wires using the appropriate mating connector Molex P N 39 01 4030 Ensure that the connector cavities are correctly populated per the wire cavity table on p 3 Note connection of occupancy sensor to the dimming leads will reduce light output to 20 normal output e Make output contact closure connections as noted below OPTION 2 OEM or RETROFIT USING TWIST ON WIRE CONNECTORS Remove the 4 way connector from the LED Driver by cutting the wires near the connector and strip the output leads Using the appropriate wiring diagram on page 3 connect the LED Driver dimming output leads to the occupancy sensor or control system using wire connectors or other connection method approved for low temperature usage and stranded cable OPTION 1 OEM USING 4 WAY CONNECTOR Connect the LED Driver dimming output leads to the occupancy sensor or control system using the appropriate mating connector Molex P N 39 01 4046 Terminals installed should be crimped using approved tooling and process per Molex specifications Ensure that the connector cavities are correctly populated per the wire cavity table on page 3 e The GEPS6
2. 500NCMUL SY LED Driver is capable of step dimming from 100 power to 20 power when used with a normally open contact closure occupancy sensor system e When using the GEPS6500NCMUL SY for dimming applications the dimming switch setting must be switched to the left to enable the dimming feature The following is the only recommended usage of occupancy sensors with the Immersion LED lighting system Other methods such as using occupancy sensors to switch the LED driver on and off is not recommended and will void the product warranty Dimming immune swch Dimming Enabled 20 Dimming Disabled default A WARNING AVERTISSMENT Risk of electrical shock Ensure that all connection points are sealed for damp location using the appropriate method per the NEC or local electrical code Risque de choc lectrique S assurer que les points de raccordements sont scell s pour emplacement humide en employant une m thode permise par le NEC ou par le code lectrique local AXCAUTION ATTENTION Risk of injury Do not overload LED Driver 50 watts maximum per driver Do not exceed the LED light bar loading limits specified on the light bar installation instructions for a 50W driver Risque de blessure Ne pas surcharger l alimentation DEL Maximum de 50 watts par alimentation Ne pas exc der les limites de charge maximale des alimentations telles que sp cifi es dans les instructions d installation Connection Configurations For inf
3. GE Lighting IMMERSION LED Refrigerated Display Lighting Vertical amp Horizontal Cases 68595 50W LED Drivers GEPS6500NCMUL SY BEFORE YOU BEGIN FOR YOUR SAFETY Read and observe all CAUTIONS and WARNINGS shown throughout these instructions e Installation to be performed by factory trained service personnel only For use inside a commercial refrigeration case with packaged foods only e Use this unit only in the manner intended by the manufacturer If you have any questions contact the manufacturer e Before installing servicing or cleaning unit switch power off at the service panel and follow appropriate lock out tag out safety procedures This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation This Class A RFLD complies with the Canadian standard ICES 003 Ce DEFR de la classe A est conforme la NMB 003 du Canada NOTE This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and us
4. LED Driver output leads to the LED Light leads using wire connectors or other connection method approved for low temperature usage and stranded cable A For non dimming applications cap the unused wires with 5 32 4mm twist on wire connectors For Retrofit Bundle and safely secure any unused wires by way of approved wire ties and wire connectors Connect LED Driver Input e Make input AC connections using one of the two options below e The LED Driver is required to be reliably bonded to the protective ground conductor OPTION 2 OEM or RETROFIT USING TWIST ON WIRE CONNECTOR Attach the supplied green yellow ground wire from the LED Driver to a grounded metal portion of the door frame Remove the 3 way connector from the LED Driver by cutting the wires near the connector and strip the input wires Using the appropriate wiring diagram on page 3 connect the original Line and neutral wires or Line 1 and Line 2 wires for 240 nominal VAC to the LED Driver leads using twist lock wire connectors or other connection method approved for low temperature usage and stranded cable Ensure that the connector cavities are correctly populated per wire cavity table on p 3 Dimming Occupancy Sensor Contacts Output Optional e To enable dimming operation and or occupancy sensors you must connect leads from occupancy sensor or control system normally open contact to the purple and gray leads of the power supply and adjust dimming
5. ed in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense imagination at work Read these instructions completely and carefully Installation Guide PREPARE ELECTRICAL WIRING Electrical Requirements e The power supply must be supplied with 100 240 VAC 50 60 Hz and connected to an individual properly grounded branch circuit protected by a 15 or 20 ampere circuit breaker or time delay fuse e Wiring must be 2 wire with ground and rated for 75 C 167 F All wiring must be done to NEC or local electrical codes Grounding Instructions Cable Direct e This lighting system must be connected to a grounded metal permanent wiring system or an equipment grounding conductor must be run with the circuit conductors and be connected to the equipment grounding terminal AXCAUTION ATTENTION Risk of injury While performing installations described gloves safety glasses or goggles should be worn Risque de blessure Lors de l ex cution des installations d crites des gants des lunettes de s curit ou des lunettes de protection doivent tre port es WARNING AVERTISSMENT Risk of electrical shock Disconnect power before servicing or installing product LED Retrofit Kit Installation requires knowledge o
6. f luminaires electrical systems If not qualified do not attempt installation Contact a qualified electrician Install this kit only in the luminaires that have the construction features and dimensions shown in the photographs and or drawings Risque de choc lectrique Couper le courant avant de r parer ou installer le produit LED Retrofit Kit d installation n cessite la connaissance des syst mes luminaires lectriques Si vous n tes pas qualifi ne tentez pas l installation Contactez un lectricien qualifi Installez ce kit seulement dans les luminaires qui ont les caract ristiques de construction et les dimensions figurant sur les photographies et ou des dessins Connect LED Driver Output e For retrofit place LED driver in the location where the ballast was formerly located e Make output DC connections as noted below OPTION 1 OEM USING 4 WAY CONNECTOR OPTION 2 OEM or RETROFIT USING TWIST ON WIRE CONNECTORS Connect the LED Driver output leads to the LED Light leads using the appropriate mating connector Molex P N 39 01 4046 Terminals installed should be crimped using approved tooling and process per Molex specifications Ensure that the connector cavities are correctly populated per the wire cavity table on page 3 Remove the 4 way connector from the LED Driver by cutting the wires near the connector and strip the output leads Using the appropriate wiring diagram on page 3 connect the
7. ormation on A B C D see Steps 1 2 and 3 Refer to LED Light Bar installation instructions for LED light bar wiring configurations Typical Installation SWITCH Note LED Lights are polarity insensitive Wire Cavities 39 01 4030 AC Cavity 1 Line 1 Black Cavity 2 Earth Ground Green Cavity 3 Neutral or Line 2 White 39 01 4046 DC Cavity 1 Output DC Red Cavity 2 Output DC Black Cavity 3 Dimming Purple Cavity 4 Dimming Gray avo 1H91 037 Occupancy Sensor WHITE NEUTRAL TERMINAL BLOCK AC SOURCE BLACK LINE This product is intended to be used as a lamp control gear that is installed after the mains control switch GE Lighting Solutions e 1 888 MY GE LED 1 888 69 43 533 e www gelighting com GE Lighting Solutions LLC is a subsidiary of the General Electric Company Immersion is a trademark of GE Lighting The GE brand and logo are trademarks of the General Electric Company Information provided is subject to change without notice All values are design or typical values when measured under laboratory conditions 2014GE 68595 081414