Home

GE r08654v-1 User's Manual

image

Contents

1. establish the cutout width corners drawers walls ete p h ge p etc when door is open of cutout If the cabinet does not have a solid bottom 2 x 4 5 cm x 10 cm or two braces or runners must be installed RE bnon ot eo level with the bottom of the cutout to support the weight of the oven For single ovens the runners and braces must support 150 Ibs 68 Kg N w access from ed i Allow adjacent cabinet are less than 3 4 1 9 cm thick NOTE If marks blemishes or the cutout opening are visible above the installed oven it may be necessary to add wood shims under the runners and front trim until the marks or opening 18 45 7 cm gt are covered 27 68 6 cm gt These ovens are not approved for stackable installations Installation Instructions A Cutout for 27 68 6 cm Double Built In Ovens only For JKP35 JKP55 JKP75 PK956 ZEK958 models only 5 12 7 cm Max from the left or right Width ge cm cutout 25 63 5 oe Min ch 25 1 4 64 1 cm Max e Cabinet Location Allow 1 2 5 cm for overlap of oven over side edges of cutout gt lt 44 111 8 cm Cutout Min Height 49 11 16 126 2 cm Min 50 1 8 127 3 cm Max r n Above 2 x4 base rail 5 cm x 10 cm or equivalent runners Allow 4 2 5 cm for ov
2. 762cm Single or Double Built In Ovens only Over a Warming Drawer For JTP30 JTP35 JTP55 JTP70 JTP75 PT916 PT920 PT956 PT960 ZET938 ZET958 models only Single 30 76 2 cm Double 30 76 2 cm Oven Over a Warming Oven Over a Warming Drawer Drawer Anti Tip Block Against a eee oo Rear Wall Per Warming Anti Tip Block Drawer Requirement Against Rear H Wall Per 2 5 1 cm i Warming Min i Drawer NOTE Install the Requirement oven only with i 2 5 1 cm specific models i Min r F listed on the label E gt Per Warming o located on top of Ns Wo tt Drawer oe the oven Requirement p Per Warming Drawer Requirement 1 2 5 cm Min Above Toekick or Adjust to Oven Installation Height NOTE Additional clearances between cutouts When installing a Warming Drawer below may be required Check to be sure the oven a single or double oven a separate 120V supports above the Warming Drawer location 60 Hz properly grounded receptacle must do not obstruct the required interior depth and be installed Refer to installation instructions height packed with the Warming Drawer for specific installation requirements 1 2 5 cm Min Above Toekick 12 Cabinetry A Cutout for 30 76 2cm Single Ovens only Below an Advantium or Microwave Oven or Between an Advantium or Microwave Oven and a Warming Drawer For JTP30 JTP70 PT916 PT920 ZET938 models only Single
3. 76 2 cm Single Built In Ovens only For JTP30 JTP70 PT916 PT920 ZET938 models only Cabinet Width Recommended Cutout Location from Floor Cutout Depth Cutout Width Cutout 9 1 2 24 1 cm 30 76 2 cm Width Max 28 1 2 72 4 cm Location Min gt junction box 28 5 8 72 7 cm may be located in adjacent cabinet Junction Box 32 1 2 82 6 cm 23 1 2 59 7 cm Min 28 1 2 72 4 cm Min 28 5 8 72 7 cm Max 27 1 4 69 2 cm Min 27 5 16 69 4 cm Max MEEN NOTE If the cabinet does not have a front frame and the sides are less than 3 4 1 9 cm thick shim both sides equally to establish the cutout width Allow 11 16 1 75 cm for overlap of oven over side edges SASS of cutout Opening Between Cutout Height 27 1 4 69 2 cm Min 27 5 16 69 4 cm Max Inside Walls N Cutout Height Must Be At Least 22 55 9 cm Min to Bottom of 29 1 2 Junction Box 72 4 cm Wide 21 53 3 cm 7 _7 gt lt 2 7 Recommended cutout location from floor 32 1 2 82 6 cm Allow 1 2 5 cm minimum for overlap of oven Allow a minimum top and 11 of 21 53 3 cm for 3 2 cm overlap clearance to adjacent of oven bottom corners drawers of cutout walls etc when Cabinet door is open Width 30 76 2 cm 2 x 4 5 cm x 10 cm or equivalent runners level with bottom If the cabinet does not
4. debe usar tornillos 8 x 3 4 Los puede adquirir en cualquier ferreteria 16 Instrucciones de instalacion Preparaci n para la instalaci n C mo instalar la moldura de la moldura de fondo de fondo met lica Con el horno instalado tome la moldura de a Coloque la moldura de fondo centrada sobre fondo y c ntrela en el borde frontal del fondo los orificios pre taladrados Adhiera los bordes de la abertura del gabinete de la moldura en la parte inferior con una cinta adhesiva para mantener la alineaci n Usando la moldura Para modelos de 27 como una plantilla 68 6 cm con x Usando los dos tornillos de la moldura moldura inferior en marque el centro de posici n marque proporcionados asegure la moldura de fondo cada ranura dos pto Same al borde del fondo del gabinete de los orificios en total donde los de montaje Si Ubicaciones de los orificios de montaje 74 tornillos de m ldur gt _ 2 para modelos de 2 2 Moldura ser n taladrados lt FA 27 68 6 cm con E lateral moldura inferior Retire la moldura AN Taladre los orificios Retirela S0r re2em con Moldura _ moldura moldura inferior lateral piloto en el centro inferir a ir de cada marca antes de margue Moldura inferior i taladrar I indicada con lc 2 ubicaciones Z rio los orificios de los orificios met lica de montaje i la plantilla de montaje Ubicaciones de los aqui tornillos de moldura para m
5. las instrucciones para la instalaci n que se remiten los apoyos del horno por encima de la ubicaci n de con cada producto para obtener los requisitos espec ficos la gaveta de calentamiento no dificulten la profundidad ER i y altura interior requerida El carril del medio que separa Instalaci n para el horno combinado las dos aberturas pueden necesitar ser m s grande que Advantium o horno de microondas y el de 2 5 1 cm de m nimo que se muestra Siempre de pared consulte las instrucciones para la instalaci n que Para la instalaci n en combinaci n con un horno il ia para obtener individual de pared utilice una caja de conexiones q P i el ctricas separada Gaveta de calentamiento combinada Consulte las instrucciones de instalaci n del horno con Advantium o horno de microondas Advantium o del horno de microondas para obtener los requisitos de ese producto y horno individual Un electricista autorizado debe realizar estas Instale un recept culo separado de 120V 60Hz conexiones Todas las conexiones el ctricas debe adecuadamente con conexi n a tierra Consulte cumplir con las normas del C digo El ctrico Nacional las instrucciones de instalaci n remitidas con cada o los c digos locales vigentes producto para obtener los requisitos espec ficos Instrucciones de instalacion Conexiones el ctricas B1 B2 ATENCION AL INSTALADOR Todos los hornos el ctricos de pared deben ser cableados directamente en una
6. mo taladrar los orificios piloto y montar el horno NOTA Antes de perforar los orificios piloto cerci rese de que el horno se empuj hasta el fondo y de que est centrado Perfore a trav s de los orificios de montaje arriba y abajo de la moldura lateral para Tire hacia afuera los tornillos 8 que se proporcionan por el lazo de la cuerda mientras empuja el horno hacia el interior del gabinete Ubicaci n de y de l Los tornillos deben los orificios bas LE m q estar a un m nimo as de montaje de 1 4 6 mm del ohn mae Cee frente del corte rat Levante el horno hacia el interior del corte en el gabinete usando la abertura del horno para agarrarlo Empuje contra el LL marco frontal del horno cuidadosamente No empuje contra los bordes externos ADVERTENCIA Se deben usar tornillos de montaje No hacerlo podr a resultar en que el horno se caiga del gabinete causando lesiones serias c A medida que el horno se desliza hacia atr s tire de la cuerda para que el conducto quede encima del horno de forma natural Cuando est seguro de que el conducto est fuera del camino deslice el horno 3 4 del trayecto hacia atr s y hacia el interior de la abertura Retire la cuerda halando de un extremo b Ajuste bien el horno al gabinete con los tornillos que se proporcionan NOTA Si el gabinete es en tabla aglomerada
7. 1 4 64 1 cm Max 5 cm x10 cm del corte o correceras 27 5 8 70 2 cm Min Altura de corte 27 5 8 70 2 cm Min Anele ada con a 28 1 8 71 4 cm M x el fondo del corte 20 50 8 cm St j Conexi n alterna A Ubicaci n de la caja NOTA Si el gabinete no tiene E et Ubicaci n Puede requerirse a rada el acceso desde un marco frontal y los lados tas mi imn m nimo de para el corte l gabinete adyacente son menores de 3 4 1 9 cm 1 2 5 cm para desde el en grosor coloque ambos pol i el sobrepaso piso 32 1 2 Ho l q tabl del horno por 82 6 cm ados en linea para establecer esquinas cajones paredes etc O 7 lt el ancho del corte el corte adyacentes cuando la puerta est abierta 2 x 4 5 cm x 10 cm o Si el gabinete no tiene un fondo s lido correderas equivalentes entonces se deben instalar dos abrazaderas o rer EOE correderas nivelada con el fondo del corte para sostener el peso del horno Para hornos de una A unidad las correderas o abrazaderas deben soportar 150 libras 68 Kg J NOTA Si las marcas imperfecciones o 24 61 cm la abertura del corte son visibles por encima del horno instalado quiz s sea necesario agregar relleno debajo de las correderas y moldura delantera hasta que se cubran 18 45 7 cm gt lt 27 68 6 cm gt Estos hornos no est n aprobados par
8. 2 cm WB07T10578 Negro WB07T10579 SS Montaje de moldura de fondo met lica opcional de 27 68 6 cm en algunos modelos o pueden adquirirse por separado 31 10647 3 11 07 JR e La instalaci n apropiada es responsabilidad del instalador y la falla del producto por una instalaci n incorrecta NO est cubierta por la garant a NOTA Este aparato debe estar conectado a tierra adecuadamente ATENCI N AL INSTALADOR Todos los hornos electr nicos de pared deben ser cableados directamente en una caja de conexi n aprobada Un enchufe recept culo NO ES permitido en estos productos Materiales necesarios 6 Tuercas para e alambres Abrazadera de alivio Caja de de presi n para conexi n conducto de 1 2 Cord n de 36 91 cm Herramientas necesarios Una broca de 1 8 3 mm para Destornillador taladro el ctrico o manual de estrella Instrucciones de instalacion INSTRUCCIONES DE SEGURIDAD IMPORTANTES Para su seguridad e Cerci rese de que su horno sea instalado adecuadamente por un instalador calificado o por un t cnico de servicio Cerci rese de que su horno est firmemente instalado en un gabinete que est firmemente adherido a la estructura de la casa El peso sobre la puerta del horno podr a causar que el horno se voltee resultando en lesiones Nunca permita que nadie se suba se siente se pare o se cuelgue de la puerta del horno Cerci rese de
9. cm L nea de centro sobre gabinetes Instalaciones de lado a lado Instale dos hornos en disyuntores separados Deje 2 5 1 cm m n entre disyuntores 2 5 1 cm Disyuntor Min Instrucciones de instalaci n A Corte para los hornos de dos unidades de 30 76 2 cm solamente Para los modelos JTP35 JTP55 JTP75 PT956 PT960 ZET958 solamente Permita 11 16 1 75 cm para sobrepaso del _y horno sobre los bordes laterales del corte Permita un m nimo de 21 53 3 cm de espacio para las esquinas cajones paredes etc adyacentes cuando la puerta est abierta Ancho del corte 28 1 2 72 4 cm M n lt lt 285 8 gt 72 7 cm Max Abertura entre los paredes interiores debe estar un minimo de 28 1 2 72 4 cm de ancho Permita un minimo de 1 2 5 cm para el sobrepaso del horno por encima y 1 9 1 2 24 1 cm M x la caja Ubicaci n de la caja de conexi n Ancho del gabinete Ubicaci n 30 76 2 cm de conexi n recomendada puede estar ubicada en y un gabinete desde el piso adyacente 47 119 4 cm M n hasta la parte inferior de la caja de conexi n Altura del corte 51 13 16 131 6 cm M n 51 15 16 131 9 cm Max para el corte 12 30 5 cm Profundidad del corte Ancho del corte 23 1 2 59 7 cm Min 28 1 2 72 4 cm Min 28 5 8 72 7 cm Max 51 13 16 131 6 cm Min 51 1
10. contra i p i a pare Fi cm trasera para in la gaveta de NOTA Instale el calentamiento horno s lo con los i requisitos modelos espec ficos 2 5 1 cm enumerados en la i M n gt cS etiqueta que se ubica i UL calentamiento A en la parte superior es oa requisitos del horno Bloque estable Para la gaveta de calentamiento requisitos 1 2 5 cm M n Por encima del z calo o ajustar a la altura de la E P instalaci n del horno 1 2 5 cm M n Por encima del z calo NOTA Puede necesitarse una separaci n e Para la instalaci n de una gaveta de adicional entre los disyuntores Verifique para calentamiento por debajo de un horno asegurarse de que los apoyos del horno por individual o doble debe instalarse un encima de la ubicaci n de la gaveta de recept culo con conexi n a tierra separado calentamiento no dificulten la profundidad de 120V 60Hz Consulte las instrucciones y altura interior requerida para la instalaci n remitidas con la gaveta de calentamiento para obtener los requisitos espec ficos de instalaci n Gabinetes A Disyuntor para 27 68 6 cm Solamente para hornos individuales Debajo de un Advantium o de un horno de microondas o Entre un horno Advantium o un horno de microondas y Gaveta de calentamiento Para los modelos JKS10 JKP30 JKP70 PK916 ZEK938 solamente Horno individual de 27 68 6 cm debajo de un horno Advantium o un horno de mic
11. de recept culo con conexi n a tierra separado calentamiento no dificulten la profundidad de 120V 60Hz Consulte las instrucciones y altura interior requerida para la instalaci n remitidas con la gaveta de calentamiento para obtener los requisitos espec ficos de instalaci n 12 Gabinetes A Disyuntor para 30 76 2 cm Solamente para hornos Individuales Debajo de un Advantium o de un horno de microondas o Entre un horno Advantium o un horno de microondas y Gaveta de calentamiento Para los modelos JTP30 JTP70 PT916 PT920 ZET938 solamente Horno individual de 30 76 2 cm Horno individual de 30 76 2 cm debajo de un horno Advantium o Entre un horno Advantium o un horno de microondas un horno de microondas y una gaveta de calentamiento Por Advantium o hofia Por Advantium o horno de de microondas requisitos 2 5 1 cm M n microondas requisitos Nota Instale el i i horno s lo con los i i modelos espec ficos 2 5 1 cm M n lo enumerados en la Doen s Ni beeen etiqueta que se PRS eN ubica en la parte e d superior del horno a 2 5 1 cm M n Por gaveta de calentamiento requisitos eae NOTA El carril del medio que separa las dos aberturas pueden necesitar ser m s grande que el de 2 5 1 cm NOTA Puede necesitarse una separaci n adicional de m nimo que se muestra Siempre consulte entre los disyuntores Verifique para asegurarse de que
12. have a solid bottom ot c to t two braces or runners must be installed level with the bottom of the cutout to support the weight of the oven For single ovens the runners and braces must support 150 Ibs 68 Kg NOTE If marks blemishes or the cutout opening are visible above the installed oven it may be necessary to add wood shims under the runners and front trim until the marks or opening are covered These ovens are not approved for stackable installations Suitable Bracing to Support Runners T 5 8 Fes 9 cm Over Centerline of Cabinet Side by Side Installations Install two wall ovens in separate cutouts Allow 2 5 1 cm min between cutouts 2 5 1 dd Cutout Observe all dimensions Cutout Observe all dimensions Installation Instructions A Cutout for 30 76 2 cm Double Built In Ovens only For JTP35 JTP55 JTP75 PT956 PT960 ZET958 models only Cutout 9 1 2 Width 241 cm Junction Box 28 1 2 72 4 cm Location lt Min gt junction box 28 5 8 72 7 cm may be located in adjacent cabinet Allow 11 16 1 75 cm for overlap of oven over side edges of cutout Opening Between Inside Walls Must Be At 47 119 4 cm Least 28 1 2 Min Allow a minimum 72 4 cm Wide y to Bottom of of 21 53 3 cm for Junction Box clearance to adjacent corners drawers Cutout walls etc when Allow 1 2 5 cm Height door is open min
13. horno para los modelos de estufas aprobados Material de relleno para la parte superior y o lados podr a ser necesario si la unidad est ubicada entre gabinetes existentes Aseg rese de que est pegado firmemente ya que ste anclar el horno en el gabinete ole 28 5 8 72 7 cm Max 27 1 4 69 2 cm Min 27 5 16 69 4 cm Max de conexi n 240V 208V la caja de conexi n puede estar ubicada en un gabinete adyacente 9 1 2 24 1 cm Max 28 1 2 72 4 cm M n 1 Permita 1 2 5 cm para el sobrepaso del horno por Ll encima 11 16 gt 1 8 cm para el sobrepaso de los 4 bordes laterales del corte y 1 1 4 3 2 cm para el sobrepaso del horno debajo Ubicaci n de la caja Las conexiones de gas y el ctricas para una estufa a gas de deben estar ubicadas en un lugar adyacente de f cil acceso en el lado derecho 22 55 9 cm Min Por encima de la plataforma de soporte 36 91 4 cm Altura t pica del gabinete 24 61 cm 4 10 2 cm Z calo t pico Plataforma de 3 4 1 9 cm de soporte et _tequerida _ a s NOTA Este horno est aprobado s lo para instalarse bajo los modelos espec ficos indicados en esta unidad Debe equiparar la altura del z calo rt DEBE SOPORTAR 150 LIBRAS 68 Kg Instalaciones de lado a lado Instale dos hornos en disyuntores separados Deje 2 5 1 cm min Observ
14. oven door as far as it will open D4 Push the hinge locks up against the front frame of the oven cavity to the locked position Hinge in Locked Position Notch of Hinge Securely Fitted into Bottom of Hinge Slot Close the oven door W Pre Test Checklist lt 8 RRR RS Installation Instructions Remove all protective film if present and any stickers Check to be sure that all wiring is secure and not pinched or in contact with moving parts Check that the bottom trim is installed properly see page 17 Check to be sure the mounting screws are installed and flush with the side trim see page 16 Operation Checklist Remove all items from the inside of the oven Check that conduit is securely connected to the junction box Turn on the power to the oven Refer to your Owner s Manual Verify that the bake and broil units and all cooking functions operate properly Check that the circuit breaker is not tripped nor the house fuse blown See your Owner s Manual for troubleshooting list NOTE TO ELECTRICIAN The power leads supplied with this appliance are UL recognized for connections to larger gauge household wiring The insulation of these leads is rated at temperatures much higher than the temperature rating of household wiring The current carrying capacity of a conductor is governed by the wire gauge and also the temperature rating of the insulation around the wire NOTE ALUMI
15. 3 KW 40 Amp 7 KW 12 0 KW 8 4 KW 10 4 KW 50 Amp Electrical Requirements cont Rating plate is located on oven side trim side front frame or lower front frame Rating Plate Location We recommend you have the electrical wiring and hookup of your oven connected by a qualified electrician After installation have the electrician show you where your main oven disconnect is located Check with your local utilities for electrical codes which apply in your area Failure to wire your oven according to governing codes could result in a hazardous condition If there are no local codes your oven must be wired and fused to meet the requirements of the National Electrical Code ANSI NFPA No 70 Latest Edition You can get a copy by writing National Fire Protection Association Batterymarch Park Quincy MA 02269 Effective January 1 1996 the National Electrical Code requires that new but not existing construction utilize a four conductor connection to an electric oven When installing an electric oven in new construction a mobile home recreational vehicle or an area where local codes prohibit grounding through the neutral conductor follow the instructions in the section on NEW CONSTRUCTION AND FOUR CONDUCTOR BRANCH CIRCUIT CONNECTION You must use a three wire single phase A C 208Y 120 Volt or 240 120 Volt 60 hertz electrical system If you connect to aluminum wiring properly installed connectors approved for use wi
16. 30 76 2 cm Oven Below an Advantium or Microwave Oven Per Advantium or Microwave Oven Requirement 2 5 1 cm Min NOTE The middle rail separating the two openings may need to be larger than the 2 5 1 cm minimum shown Always refer to the individual installation instructions packed with each product for specific requirements Combined Advantium or Microwave Oven and Wall Oven Installation When installed in combination with a single wall oven use separate electrical junction boxes e Refer to the Advantium or microwave oven installation instructions for electrical requirements of that product e These connections must be made by a qualified electrician All electrical connections must meet National Electrical Code or prevailing local codes Note Install the oven only with y specific models Loar listed on the label AN located on top of Far LL the oven Single 30 76 2 cm Oven Between an Advantium or Microwave Oven and a Warming Drawer Per Advantium or Microwave Oven Requirement 2 5 1 cm Min 2 5 1 cm Min Per Warming Drawer x a i ed NOTE Additional clearances may be required Check to be sure the oven supports above the Warming Drawer do not obstruct the required interior depth and height The middle rail separating the openings may need to be larger than the 2 5 1 cm minimum shown Always refer to the individual installation instructi
17. 5 16 131 9 cm Max Altura de corte NOTA Si el gabinete no tiene un marco frontal y los lados son menores de 3 4 1 9 cm en grosor coloque ambos lados en l nea para establecer el ancho del corte 3 2 cm por debajo del corte 21 53 3 cm J Ancho del gabinete 30 76 2 cm 2x4 5 cm x 10 cm o correderas equivalentes niveleada con el fondo del corte Ubicaci n recomendada para el corte desde el piso 12 30 5 cm Abrazaderas de soporte adecuadas para las correderas Si el gabinete no tiene un fondo s lido entonces se deben instalar dos abrazaderas o correderas nivelada con el fondo del corte para sostener el peso del horno Para hornos de dos unidades las correderas y abrazaderas deben soportar 275 libras 124 Kg a 21 ea 54 9 cm L nea de centro sobre gabinetes NOTA Si las marcas imperfecciones o la abertura del corte son visibles por encima del horno instalado quiz s sea necesario agregar relleno debajo de las correderas y moldura delantera hasta que se cubran Instrucciones de instalacion A Corte para los hornos de una unidad debajo de la superficie del gabinete de 30 76 2 cm solamente Para los modelos JTP30 JTP70 PT916 PT920 ZET938 solamente Las estufas el ctricas o de gas se pueden instalar sobre este horno Consulte las instrucciones de la estufa para el tama o del corte Consulte la etiqueta encima del
18. Installation Instructions Built In Wall Oven 27 68 6 cm models JKS10 JKP30 JKP35 JKP55 JKP70 JKP75 PK916 PK956 ZEK938 ZEK958 30 76 2 cm models JTP30 JTP35 JTP55 JTP70 JTP75 PT916 PT920 PT956 PT960 ZET938 ZET958 If you have questions call 1 800 GE CARES or visit our website at ge com Before You Begin Read these instructions carefully and completely e l M PO RTANT save these instructions for local inspector s use IMPORTANT observe all governing codes and ordinances Note to Installer Be sure to leave these instructions with the consumer e Note to Consumer Keep these instructions for future reference Parts Included Appearance will vary Screws For Installation a 27 68 6 cm 8 18 x 750 flat head j Metal Bottom Trim Phillips wood screws 30 76 2 cm WB07T10578 Black Metal Bottom Trim WB07T10579 SS Assembly Optional 27 68 6 cm Metal Bottom Trim Assembly on some models or can be purchased separately 31 10647 3 11 07 JR e Proper installation is the responsibility of the installer and product failure due to improper installation is NOT covered under warranty e NOTE This appliance must be properly grounded ATTENTION INSTALLER All electric wall ovens must be hard wired direct wired into an approved junction box A plug and receptacle is NOT permitted on these products Materials Needed eS 9 Wire Nuts Strain
19. NUM WIRING A WARNING improper CONNECTION OF ALUMINUM HOUSE WIRING TO THE COPPER LEADS CAN RESULT IN AN ELECTRICAL HAZARD OR FIRE Splice copper wires to aluminum wiring using special connectors designed and UL approved for joining copper to aluminum and follow the manufacturer s recommended connector procedure closely NOTE Wire used location and enclosure of splices etc must conform to good wiring practice and local codes Notes Instrucciones de instalacion Horno de pared empotrado Modelos de 27 68 6 cm JKS10 JKP30 JKP35 JKP55 JKP70 JKP75 PK916 PK956 ZEK938 ZEK958 Modelos de 30 76 2 cm JTP30 JTP35 JTP55 JTP70 JTP75 PT916 PT920 PT956 PT960 ZET938 ZET958 Preguntas Visite nuestro sitio en la Web ge com Antes de empezar Lea estas instrucciones cuidadosa y completamente IM PO RTANT E cuarde estas instrucciones y t ngalas disponibles para el inspector local e l M PO RTANTE observe todos los c digos y ordenanzas vigentes e Nota al instalador Cerci rese de dejar estas instrucciones con el propietario Nota al consumidor Guarde estas instrucciones para usarlas como referencia en el futuro Partes incluidas Papariencia puede variar la Moldura de fondo Tornillos para met lica de 27 instalaci n tornillos 68 6 cm para madera tipo Phillips de cabeza plana 8 18 x 750 Montaje de moldura de fondo met lica de 30 76
20. Rear Anti Tip Block Against Wall Per Rear Wall Per Warming Warming Drawer Requirement i Drawer 2 5 1 cm Requirement Min NOTE Install the 2 6 1 em oven only with i in specific models listed on the label located on top of Lo the oven Requirement Per Warming Drawer Requirement 1 2 5 cm Min Above Toekick 1 2 5 cm Min Above Toekick or Adjust to Oven Installation Height NOTE Additional clearances between cutouts e When installing a Warming Drawer below may be required Check to be sure the oven a single or double oven a separate 120V supports above the Warming Drawer location 60 Hz properly grounded receptacle must do not obstruct the required interior depth and be installed Refer to installation instructions height packed with the Warming Drawer for specific installation requirements Cabinetry A Cutout for 27 68 6 cm Single Ovens only Below an Advantium or Microwave Oven or Between an Advantium or Microwave Oven and a Warming Drawer For JKS10 JKP30 JKP70 PK916 ZEK938 models only Single 27 68 6 cm Oven Below an Advantium or Microwave Oven Per Advantium or Microwave Oven Requirement 2 5 1 cm Min Single 27 68 6 cm Oven Between an Advantium or Microwave Oven and a Warming Drawer Per Advantium or Microwave Oven Requirement H 2 5 1 cm Min Note Install the oven on
21. Relief Clamp Junction for 1 2 conduit Box SS 36 91 cm of String Tools Needed SAR x 1 8 3 mm Drill Bit and Phillips Electric or Hand Drill Screwdriver Installation Instructions IMPORTANT SAFETY INSTRUCTIONS For Your Safety e Be sure your oven is installed properly by a qualified installer or service technician e Be sure the oven is securely installed in a cabinet that is firmly attached to the house structure Weight on the oven door could cause the oven to tip and result in injury Never allow anyone to climb sit stand or hang on the oven door e Make sure the cabinets and wall coverings around the oven can withstand the temperatures up to 200 F 93 3 C generated by the oven WARNING The electrical power to the oven supply line must be shut off while line connections are being made Failure to do so could result in serious injury or death j Electrical Requirements This appliance must be supplied with the proper voltage and frequency and connected to an individual properly grounded branch circuit protected by a circuit breaker or fuse See the rating plate located on the oven frame to determine the rating of the product Use the chart below to determine the minimum recommended dedicated circuit protection Recommended KW Rating KW Rating Circuit Size 240V 208V Dedicated lt 4 8 KW lt 4 1 KW 20 Amp 9 KW 7 2 KW 4 3 KW 6 2 KW 30 Amp 3 KW 9 6 KW 6 3 KW 8
22. a las instalaciones apilables Instrucciones de instalacion A Corte para los hornos de dos unidades de 27 68 6 cm solamente Para los modelos JKP35 JKP55 JKP75 PK956 ZEK958 solamente 5 12 7 cm Max espacio para Ancho del el lado izquierdo o derecho gabinete 27 68 6 cm Ancho del gabinete _ az 27 68 6 cm Ubida i n Ubicaci n TEIE de la caja recomendada pager ne de conexi n para el corte te 25 Cy 4 63 5 cm Min 1 E desde el piso 13 1 4 33 7 cm Permita 1 2 5 cm 25 1 4 64 1 cm Max para sobrepaso del SE i Profundidad horno sobre los j n 7 bordes laterales US del corte 23 5 8 60 cm Min del corte i 44 111 8 cm Min ecu ce de Ancho del corte 25 63 5 cm Min ee a Minion este 25 1 4 64 1 cm Max 5 cm x 10 cm 49 11 16 126 2 cm Min A o correderas 50 1 8 127 3 cm M x Altura de corte 49 11 16 126 2 cm M n equivalentes 50 1 8 1 27 3 cm M x ne ia son menores de 3 4 1 9 cm Y a Permita un minimo Ubicaci n en grosor coloque ambos S N A NOTA Si el gabinete no tiene a a gt i un marco frontal y los lados de 1 2 5 cm para recomendada para lados en l nea para establecer Permita un m nimo el sobrepaso el corte desde el de 20 50 8 cm de del horno por encima piso 13 1 4 33 7 cm el ancho del corte espacio para las y debajo del corte esquinas cajones paredes
23. a que le muestre la ubicacion del interruptor principal del horno Consulte con su compa a de servicios local para obtener los c digos el ctricos que sean aplicables en su rea No hacer el cableado de su horno de manera apropiada respetando los c digos vigentes podr a resultar en condiciones peligrosas Si no existen c digos locales su aparato debe usar un cableado y fusibles que cumplan con los requisitos del C digo El ctrico Nacional ANSI NFPA No 70 Ultima edici n Usted puede obtener una copia de este c digo escribiendo a National Fire Protection Association Batterymarch Park Quincy MA 02269 A partir del 1ro de enero de 1996 el C digo El ctrico Nacional requiere que todas las construcciones nuevas pero no existentes usen una conexi n de 4 conductores hacia cualquier horno el ctrico Cuando instale un horno el ctrico en una construcci n nueva casa m vil veh culo de recreaci n o un rea donde los c digos locales proh ban la conexi n a tierra a trav s del conductor neutro siga las instrucciones en la Secci n CONSTRUCCIONES NUEVAS Y CONEXIONES DE CIRCUITOS RAMALES DE 4 CONDUCTORES Usted debe usar un sistema el ctrico de tres alambres monofasico A C 208Y 120 voltios o 240 120 voltios 60 Hertz Si hace una conexi n a alambres de aluminio debe usar conectores adecuadamente instalados que est n aprobados para ser utilizados con cableados de aluminio Instrucciones de instalaci
24. ara PODR A RESULTAR EN PROBLEMAS una lista de problemas eventuales SERIOS O EN INCENDIO Conecte los alambres de cobre a los alambres de aluminio usando conectores especiales dise ados y aprobados por UL para unir cobre y aluminio y siga cuidadosamente el procedimiento para hacer las conexiones recomendadas por el fabricante NOTA El alambrado que se use la ubicaci n y el tipo de conexi n etc deben cumplir con las buenas pr cticas de alambrado y los c digos locales 19 Notas
25. asta que los brazos de la bisagra salgan de la ranuras Bisagra sale de la ranura NOTA La puerta del horno es muy pesada Aseg rese de tenerla bien agarrada antes de levantarla de las bisagras Tenga cuidado una vez que retire la puerta No acueste la puerta sobre la empu adura esto podr a causar marcas y rayas Coloque el horno sobre la mesa o plataforma al nivel de la abertura del corte La plataforma debe soportar 150 libras 68 Kg para hornos de una unidad y 275 libras 124 Kg para hornos de dos unidades Extraiga la moldura de fondo de la parte superior del horno La misma ser instalada al final de la instalaci n La moldura de fondo est envuelta por separado y pegada a la parte superior de la unidad Instrucciones de instalacion A Corte para los hornos de una unidad de 27 68 5 cm Solamente Para los modelos JKS10 JKP30 JKP70 PK916 ZEK938 solamente 5 12 7 cm M x i el lado Izquierdo Ancho del o derecho gabinete 27 68 6 cm pions Ubicacion de la 68 6 cm caja de conexi n Ubicaci n mmm recomendada Ancho para el corte del corte desde el piso 32 1 2 82 6 cm Permita 1 2 5 cm 25 63 5 cm Min 25 1 4 64 1 cm 7 M x Profundidad daa S del corte 23 1 2 59 7 cm Min sobre los bordes 22 55 9 cm laterales del corte Min Sobre n i I t ee Ancho del corte 25 63 5 cm Min 2 x 4 Altura la base 25
26. caja de conexion Una enchufe receptaculo NO ES permitido en estos productos NO acorte el conducto flexible La abrazadera para controlar la presi n debe estar firmemente adherida a la caja de conexi n y el conductor flexible debe estar firmemente adherido a la abrazadera Si el conducto flexible no se ajusta al interior de la abrazadera no instale el horno hasta que obtenga el tama o apropiado NOTA AL ELECTRICISTA Los 3 alambres el ctricos proporcionados con este aparato son reconocidos por la UL para conexiones a cableado residencial de mayor calibre El aislante de estos 3 alambres supera las especificaciones de temperatura indicadas para cableado residencial La capacidad actual de conducci n del cable depende del calibre del cableado y de la clasificaci n de la temperatura del aislamiento alrededor del alambre ADVERTENCIA Una conexi n inapropiada del cableado de aluminio residencial con cobre podr a resultar en un peligro el ctrico o hasta en incendio Use solamente conectores dise ados para unir cobre con aluminio y siga las recomendaciones del fabricante con mucho cuidado 14 Conducto Coloque el horno en el soporte para ayudar Desconecte el interruptor del circuito o retire los fusibles que alimentan el circuito ramal del horno Con el horno enfrente de la abertura del gabinete sobre una mesa o plataforma conecte el conducto flexible a la caja de conexi n como se mu
27. ct the oven red lead to the branch circuit red lead and the oven black lead to the branch circuit black lead in accordance with local codes using wire nuts If the residence red black or white leads are aluminum conductors see WARNING on page 14 Install Junction Box Cover Three Conductor Branch Circuit Connection When connecting to a three conductor branch circuit if local codes permit a Connect the bare oven ground conductor with the crimped neutral white lead to the branch circuit neutral white or gray in color using a wire nut Ground and Neutral Wires Junction Box Cover Connect the oven red lead to the branch circuit red lead in accordance with local codes using a wire nut Connect the oven black lead to the branch circuit black lead in accordance with local codes using a wire nut If the residence red black or white leads are aluminum conductors see WARNING on page 14 Install Junction Box Cover Installation Instructions Securing the Oven in the Opening eo li Oven Into the a Loop do not tie a 36 91 cm string Drilling the Pilot Holes and Mounting the Oven around the conduit before the oven is slid into place This will keep the conduit from falling behind the oven Pull out on string loop while pushing the oven into K the cabinet Lift oven into cabinet cutout using the oven opening as a grip Carefully push against oven front frame Do not push against o
28. cte el alambre rojo del horno al alambre rojo del circuito y el alambre negro del horno al alambre negro del circuito de acuerdo con los c digos locales usando las tuercas para alambres Si los alambres rojos negros o blancos de la residencia son conductores de aluminio consulte la ADVERTENCIA en la p gina 14 e Instale la cubierta de la caja de conexi n Conexi n de circuito ramal de tres conductores Cuando conecte un circuito ramal de 3 conductores si los c digos locales lo permiten a Conecte el alambre descubierto del horno con el alambre neutro blanco del circuito ramal blanco o gris usando una tuerca para alambres Alambres de conexi n a tierra Cubierta de la caja de conexi n b Conecte el alambre rojo del horno al alambre rojo del circuito ramal usando una tuerca para alambres c Conecte el alambre negro del horno al alambre negro del circuito ramal de acuerdo a los c digos locales usando una tuerca para alambre Si los alambres rojos negros o blancos de la residencia son conductores de aluminio consulte la ADVERTENCIA en la p gina 14 d Instale la cubierta de la caja de conexi n Instrucciones de instalacion Posicion firme del horno en la abertura C mo deslizar el horno en el interior de la abertura a Coloque sin atar una cuerda de 36 91 cm alrededor del conductor antes de deslizar el horno en su lugar Esto evitar que el conducto se caiga detr s del horno C
29. de protecci n y Y Inspeccione la moldura de fondo para etiqueta que todav a est presente cerciorarse de que est instalada apropiadamente ver p gina 17 Revise para asegurarse de que todos los alambres est n bien conectados y Inspeccione para cerciorarse de que los no aplastados o en contacto con partes tornillos de montura est n instalados y m viles apretados hasta quedar al mismo nivel de la moldura lateral ver p gina 16 Lista de control para la operaci n Retire cualquier art culo del interior Y NOTA AL ELECTRICISTA Los alambres del horno el ctricos proporcionados con este aparato son reconocidos por la UL para Cerci rese de que el conducto est conexiones cableado residencial de conectado firmemente a la caja de mayor calibre El aislante de estos conexi n el ctrica alambres supera las especificaciones indicadas para cableado residencial Conecte la energ a hacia el horno La capacidad actual de conducci n del Consulte su Manual del propietario cable depende de la clasificaci n de la Verifique que las unidades de horneado y temperatura del aislamiento alrededor asado y todas las funciones de cocci n del alambre aprecien NOTA CABLEADO DE ALUMINIO Cerci rese de que el interruptor de A ADVERTENCIA circuito no se haya disparado o de que los UNA CONEXI N INAPROPIADA fusibles de la casa no est n quemados DEL CABLEADO DEL ALUMINIO RESIDENCIAL CON EL COBRE Consulte el manual del propietario p
30. e M n Disyuntor 2 5 1 cm Disyuntor Observe todas las dimensiones y requisitos todas las dimensiones y requisitos entre disyuntores Gabinetes A Disyuntor para 30 76 2 cm solamente para hornos individuales o dobles empotrados Sobre una gaveta de calentamiento Para los modelos JTP30 JTP35 JTP55 JTP70 JTP75 PT916 PT920 PT956 PT960 ZET938 ZET958 solamente Horno individual de 30 Horno doble de 30 76 2 cm sobre una 76 2 cm sobre una gaveta de calentamiento gaveta de calentamiento Bloque estable contra la pared trasera para la gaveta de calentamiento requisitos Bloque estable 2 5 1 cm contra la pared M n l trasera para la gaveta de NOTA Instale el A calentamiento horno s lo con los i requisitos modelos espec ficos 2 5 1 cm enumerados en la i M n gt cS etiqueta que se ubica i UL calentamiento A en la parte superior es dE requisitos del horno Para la gaveta de calentamiento requisitos 1 2 5 cm M n Por encima del z calo o ajustar a la altura de la 3 a instalaci n del horno 1 2 5 cm M n Por encima del z calo NOTA Puede necesitarse una separaci n e Para la instalaci n de una gaveta de adicional entre los disyuntores Verifique para calentamiento por debajo de un horno asegurarse de que los apoyos del horno por individual o doble debe instalarse un encima de la ubicaci n de la gaveta
31. en See cooktop installation instructions for cutout size See label on 240V 208V top of oven for approved cooktop models Junction Box Location junction box may be in adjacent cabinet Gas and electrical connections for gas cooktop must be located in an adjacent accessible location to the right 25 63 5 cm f t Se a ha s Top and or side fillers may be necessary if unit is positioned between existing gt oS cabinets Be sure 28 1 2 72 4 cm Min they are attached 28 5 8 72 7 cm Max securely since they j will anchor the oven in the cabinet Allow 1 2 5 cm overlap top 2 i 36 91 4 cm of oven 22 55 9 cm Min Typical _ 11 16 1 8 cm i code ppo Countertop 27 1 4 69 2 cm Min L overlap side edges Height 27 5 16 69 4 cm Max ete a of cutout and 1 1 4 3 2 cm overlap bottom of oven re 24 61 cm 1 1 i 1 A K 7 1 1 1 4 1 1 1 1 1 1 1 1 1 1 1 1 1 Big 17 4 10 2 cm ee TTS Typical ete A Toekick 3 4 1 9 0m 4 Sii _ Support Platform E Required PTT ET 1 1 1 we a NOTE This oven is only Sizs ee ae approved to be installed under the specific models as labeled MUST SUPPORT 150 LBS 68 Kg nea Side by Side Installations Install two wall ovens in separate cutouts 2 E iem Cutout Allow 2 5 1 cm min between cutouts Cabinetry A Cutout for 30
32. erlap of oven top and bottom of cutout Recommended cutout location from floor 13 1 4 33 7 cm 20 T 8 em a Allow a minimum a ie of 20 50 8 cm for clearance to adjacent corners drawers walls etc when door is open If the cabinet does not have a solid bottom two braces or runners must be installed to support the weight of the oven For double ovens the runners and braces must support 300 Ibs 135 Kg NOTE If marks blemishes or the cutout opening are visible above the installed oven it may be necessary to add wood shims under the runners and front trim until the marks or opening are covered Junction Box Cabinet Width Recommended Cutout Location from Floor Cutout Depth Cutout Width Cutout Height 27 68 6 cm 13 1 4 33 7 cm 23 5 8 60 cm Min 25 63 5 cm Min 25 1 4 64 1 cm Max 49 11 16 126 2 cm Min 50 1 8 127 3 cm Max NOTE If the cabinet does not have a front frame and the sides are less than 3 4 1 9 cm thick shim both sides equally to establish the cutout width Suitable Bracing to Support Runners 2 x 4 5 cm x 10 cm or equivalent runners level with bottom of cutout ren Over Centerline of Cabinet Installation Instructions A Cutout for 27 68 6 cm Single Built In Ovens only Under Counter For JKS10 JKP30 JKP70 PK916 ZEK938 models only Gas or electr
33. estra en la figura Coloque el conducto de manera que quede apoyado sobre la parte superior del horno en forma de bucle natural cuando se instale el horno Usted necesitar comprar una abrazadera liberadora de presi n para completar la conexi n del conducto hacia la caja de conexi n Ubicaci n de la caja de conexi n Alambres de conexi n a Abrazadera liberadora de presi n no incluida debe usarse en la caja de conexi n en la conexi n del conductor Instrucciones de instalacion Conexi n para nueva construcci n y de circuito ramal de cuatro conductores e Cuando se instale en una construcci n nueva o e Cuando se instale en una casa m vil o Al instalar en un veh culo de recreacion o Cuando los c digos locales no permitan hacer conexi n a tierra a trav s de un cable neutro a Corte la punta del alambre neutro blanco del empalme Pele la punta del alambre neutro blanco hasta exponer la extensi n apropiado del conductor Alambres de conexi n a tierra Cubierta de la caja de conexi n b Conecte el alambre de conex n a tierra verde o cobre descubierto de acuerdo a los c digos locales Si el conductor de conexi n a tierra de la residencia es de aluminio consulte la ADVERTENCIA en la p gina 14 c Conecte el alambre neutro del horno blanco al circuito ramal neutro blanco o gris de acuerdo con los c digos locales usando una tuerca para alambres d Cone
34. etc adyacentes cuando la puerta est abierta Si el gabinete no tiene un fondo s lido 2 x 4 5 cm entonces se deben instalar dos abrazaderas o x19 a o correderas nivelada con el fondo del corte para coulvaicates sostener el peso del horno Para hornos de dos niveleada unidades las correderas y abrazaderas deben pal to soportar 300 libras 135 Kg Ly Abrazaderas NOTA Si las marcas imperfecciones o de soporte la abertura del corte son visibles por adecuadas 7 paa gt AN para las encima del horno instalado quiz s sea correderas necesario agregar relleno debajo de las T 1 45 7 cm correderas y moldura delantera hasta Linea de contro que se cubran sobre gabinetes Instrucciones de instalacion Corte para los hornos de una unidad debajo de la superficie del gabinete de 27 68 6 cm solamente Para los modelos JKS10 JKP30 JKP70 PK916 ZEK938 solamente Las estufas el ctricas o de gas se pueden instalar sobre este horno Consulte las instrucciones de la estufa para el tama o del corte Consulte la etiqueta encima del horno para los modelos de estufas aprobados 5 12 7 cm M x espacio Las conexiones de gas y para el lado el ctricas para una estufa a izquierdo o gas deben estar ubicadas en derecho un lugar adyacente de f cil acceso en el lado derecho Ubicaci n de la caja de conexi n 25 63 5 cm 240V 208V Material de relleno para la parte superior
35. g two trim screws provided secure doa te a Hole Locations ell the bottom trim to the bottom edge of the of each slo gt cabinet two total where TG OS Side the mounting holes DE Trim Screw Locations for S will be drilled PA 27 68 6 cm models with IS Lower Trim im a For 30 76 2 cm Side Remove the trim Remove models with an Drill pilot holes into Before Lower Trim in cd Position Mark the center of each Pre drilling 2 Mounting S AOE template mark Mounting Hole Locations k A Metal Lower Trim Holes here Trim Screw Locations for 30 76 2 cm models with Lower Trim IMPORTANT If this unit is ever removed from the cabinet or the oven is ever pulled out for service the trim must be removed first or damage to the trim will occur 17 Installation Instructions D Replacing the Oven Door NOTE The oven door is heavy You may need help lifting the door high enough to slide it into the hinge slots Do not lift the door by the handle D1 Lift the oven door by placing one hand on each side The door is heavy so you may need help Do not lift the door by the handle D2 With the door at the same angle as the removal position which is most of the way closed seat the notch of the hinge arm into the bottom edge of the hinge slot The notch of the hinge arm must be fully seated into the bottom of the slot Hinge Arm Bottom Edge of Slot Hinge Notch 18 D3 Open the
36. ic cooktops may be installed over this oven See cooktop installation instructions for cutout size See label on top of oven for approved cooktop models 240V 208V Junction Box 5 Location 12 7 cm Max from the left or right side Gas and electrical connections for gas cooktop must be located in an adjacent accessible location to the right 25 63 5 cm Top and or side fillers may be necessary if unit is positioned between existing cabinets Be sure they are attached securely since they will anchor the oven in the cabinet gt 25 63 5 cm Min 25 1 4 64 1cm Max 22 55 9 cm Min bove Support 36 91 4 cm Platform Typical Countertop Unit overlap top Height eig and bottom of oven 1 2 5 cm unit overlap side gt 3 gt e m 24 61cm il is TY PT 4 10 2 cm Typical f Toekick 3 4 1 9 cm 72 Support Platform Required p Must 40 match toekick height MUST SUPPORT 150 LBS 68 Kg NOTE This oven is only approved to be installed under the specific models as labeled on this unit Cabinetry A Cutout for 27 68 5 cm Single or Double Built In Ovens only Over a Warming Drawer For JKS10 JKP30 JKP35 JKP55 JKP70 JKP75 PK916 PK956 ZEK938 ZEK958 models only Single 27 68 6 cm Double 27 68 6 cm Oven Over Oven Over a Warming Drawer a Warming Drawer S Anti Tip Block E l ab Against
37. imum for 51 13 16 131 6 cm overlap of oven Min top and 1 51 15 16 131 9 cm 3 2 cm overlap Max of oven bottom 21 53 3 cm Recommended cutout location from floor 12 30 5 cm If the cabinet does not have a solid bottom two braces or runners must be installed level with the bottom of the cutout to Suitable support the weight of the oven For Bracing double ovens the runners and braces aad a must support 275 Ibs 124 Kg NOTE If marks blemishes or the cutout opening are visible above the installed oven it may be necessary to add wood shims under the runners and front trim until the marks or opening are covered 10 Cabinet Width 30 76 2 cm Recommended Cutout Location from Floor 12 30 5 cm Cutout Depth 23 1 2 59 7 cm Min Cutout Width 28 1 2 72 4 cm Min 28 5 8 72 7 cm Max Cutout Height 51 13 16 131 6 cm Min 51 15 16 131 9 cm Max NOTE If the cabinet does not have a front frame and the sides are less than 3 4 1 9 cm thick shim both sides equally to establish the cutout width 2 x 4 5cm x 10 cm or equivalent runners level with bottom of cutout T 21 5 8 54 9 cm Over Centerline of Cabinet Installation Instructions A Cutout for 30 62cm Single Built In Ovens only Under Counter For JTP30 JTP70 PT916 PT920 ZET938 models only Gas or electric cooktops may be installed over this ov
38. jo del corte Ancho del gabinete 30 76 2 cm Permita un m nimo de 21 53 3 cm de espacio para las esquinas cajones paredes etc adyacentes cuando la puerta est abierta Si el gabinete no tiene un fondo s lido entonces se deben instalar dos abrazaderas o correderas nivelada con el fondo del corte para sostener el peso del horno Para hornos de una unidad las correderas o abrazaderas deben soportar 150 libras 68 Kg NOTA Si las marcas imperfecciones o la abertura del corte son visibles por encima del horno instalado quiz s sea necesario agregar relleno debajo de las correderas y moldura delantera hasta que se cubran Estos hornos no est n aprobados para las instalaciones apilables 1 22 55 9 cm Min hasta la parte inferior de la caja de conexi n Ancho del 30 76 2 cm Ubicaci n recomendada para el corte desde el piso Profundidad del corte Ancho del corte 32 1 2 82 6 cm 23 1 2 59 7 cm M n 28 1 2 72 4 cm M n 28 5 8 72 7 cm M x 27 1 4 69 2 cm M n 27 5 16 69 4 cm Max Altura de corte NOTA Si el gabinete no tiene un marco frontal y los lados son menores de 3 4 1 9 cm en grosor coloque ambos lados en l nea para establecer el ancho del corte 2 x 4 5 cm x 10 cm o correderas equivalentes niveleada con el fondo del corte Abrazaderas de soporte adecuadas para las correderas PTA 21 5 8 54 9
39. l Installations etc in a safe place Y Place the oven on a table or platform for future reference even with the cutout opening Platform must support 150 lbs 68 Kg single 275 lbs 124 Kg double Y Remove the bottom trim from the top of the oven lt will be installed at the end of the installation process The trim is wrapped separately and taped to the top of the unit Installation Instructions A Cutout for 27 68 6 cm Single Built In Ovens only For JKS10 JKP30 JKP70 PK916 ZEK938 models only Cabinet Width 27 68 6 cm 5 12 7 cm Max from the left or right Recommended Cabinet side i abine t t Junction Box Cutout Location 27 68 6 cm from Floor 32 1 2 82 6 cm Cutout Depth 23 1 2 59 7 cm Min Cutout Width y 63 5 cm i P i Allow 1 2 5 cm a ASS Cutout Width 25 63 5 cm Min f l f i oven over sida a 25 1 4 64 1 cm Max edges of cutout Va 2x4 ab 22 55 9 i j i 5 em x 10 cm _ Height Ain aave Cutout Height 27 5 8 70 2 cm Min cea level 70 2 cm Min Pase rail 28 1 8 71 4 cm Max with bottom _ 281 8 of cutout 71 4 cm Max a aa ad ESTAN Alternate Junction NOTE If the cabinet does not A q ci have a front frame and the sides may be required Allow a minimum 1 2 5 cm Recommended 20 50 8 f minimum for cutout location shim both sides equally to eaa ae to adjecant Lp overlap of from floor 32 1 2
40. ly with specific models listed on the label located on top of the oven Per Warming El 2 5 1 cm Min Na NOTE The middle rail separating the two openings may need to be larger than the 3 7 6 cm minimum shown Always refer to the individual installation instructions packed with each product for specific requirements Combined Advantium or Microwave Oven and Wall Oven Installation When installed in combination with a single wall oven use separate electrical junction boxes e Refer to the Advantium or microwave oven installation instructions for electrical requirements of that product e These connections must be made by a qualified electrician All electrical connections must meet National Electrical Code or prevailing local codes Drawer gt ese a NOTE Additional clearances may be required Check to be sure the oven supports above the Warming Drawer do not obstruct the required interior depth and height The middle rail separating the openings may need to be larger than the 2 5 1 cm minimum shown Always refer to the individual installation instructions packed with each product for specific requirements Warming Drawer Combined with Advantium or Microwave Oven and Single Oven Install a separate 120V 60Hz properly grounded receptacle See installation instructions packed with each product for specific requirements Installation Instructions A Cutout for 30
41. o por encima de la ubicaci n de la gaveta de calentamiento no dificulten la profundidad y altura interior requerida El carril del medio que separa las dos aberturas pueden necesitar ser m s grande que el de 2 5 1 cm de m nimo que se muestra Siempre consulte las instrucciones para la instalaci n que se remiten con cada producto para obtener los requisitos espec ficos Gaveta de calentamiento combinada con Advantium o horno de microondas y horno individual Instale un recept culo separado de 120V 60Hz adecuadamente con conexi n a tierra Consulte las instrucciones de instalaci n remitidas con cada producto para obtener los requisitos espec ficos Instrucciones de instalacion A Corte para los hornos de una unidad de 30 76 2 cm solamente Para los modelos JTP30 JTP70 PT916 PT920 ZET938 solamente Ubicaci n de la caja de conexi n gabinete la caja de conexi n puede estar ubicada en un gabinete adyacente Ancho del corte 28 1 2 72 4 cm M n 9 1 2 24 1 cm o AA Permita 11 16 1 75 cm para sobrepaso del gt horno sobre los bordes laterales del corte entre los paredes interiores debe estar un m nimo de 28 1 2 72 4 cm de ancho del corte 27 1 4 i 69 2 cm M n 27 5 16 69 4 cm M x 91 53 3 em gt gt 27 7 Ubicaci n recomendada para el sobrepaso 82 6 cm del horno por encima y 1 4 3 2 cm por deba
42. odelos de 30 76 2 cm con moldura inferior IMPORTANTE Si alguna vez esta unidad se retira del gabinete o para reparaci n primero se debe retirar la moldura o de lo contraio se podr a da ar 17 Instrucciones de instalacion D C mo instalar la puerta del horno D3 Abra la puerta del horno hasta el m ximo NOTA La puerta del horno es pesada Quiz s necesite ayuda para levantar y deslizar la puerta hacia abajo sobre D4 Empuje los topes de las bisagras contra las bisagras No levante la puerta por el marco frontal de la cavidad del horno la empu adura hasta alcanzar la posici n de cierre Bisagra en la D1 Levante la puerta del posicion ae cierre horno colocando una mano en cada lado La puerta es pesada y Maesta dai quiz s necesite ayuda bisagra ajustada No levante la puerta firmemente en el ins fondo de la ranura por la empunadura de la bisagra Cierre la puerta del horno Con la puerta en el mismo angulo que la posici n para remoci n que est cerrado la mayor parte del tiempo coloque la muesca del brazo de la bisagra en el interior del borde inferior de la ranura de la bisagra La muesca del brazo de la bisagra debe apoyarse completamente al fondo de la ranura Brazo de la bisagra Borde inferior de la ranura Muesca de la bisagra 18 Y S I l AI I IQ Instrucciones de instalaci n Lista de control antes de la prueba Retire cualquier cinta
43. on W Lista de control antes de la instalaci n TODA LA INFORMACI N PARA LA INSTALACION EN LAS PAGINAS SIGUIENTES ES PARA SER USADA EN LA INSTALACION DE HORNOS DE UNA O DOS UNIDADES Y Retire los materiales de embalaje Revise detr s de las bisagras y debajo del fondo falso Retire las etiquetas de la puerta el pl stico de las molduras y panel todas las cintas alrededor del horno y todos de los tornillos de env o que asegure el horno a la almohadilla de la base Parrillas del horno Paquete de instrucciones Abra la puerta del horno y extraiga el paquete de instrucciones y las parrillas del horno Extraiga las instrucciones de instalaci n del paquete y l alas cuidadosamente antes de empezar la instalaci n Cerci rese de guardar bien todas las instrucciones Manual del propietario Instalaci n etc para referencia en el futuro No es necesario retirar la puerta para la instalaci n del producto pero hacerlo facilita la instalaci n Para retirar la puerta Y Abra la puerta del horno hasta el m ximo Y Empuje los topes de OS las bisagras hacia _ fe la bisagra abajo hacia el Y marco de la puerta hasta la posici n abierta Esto podr a requerir el uso de un ej destornillador plano bisagra Coloque las manos en ambos lados de la puerta cierre la puerta del horno hasta la posici n de remoci n que est cerrado la mayor parte del tiempo Levante la puerta y hale hacia fuera h
44. ons packed with each product for specific requirements Warming Drawer Combined with Advantium or Microwave Oven and Single Oven Install a separate 120V 60Hz properly grounded receptacle See installation instructions packed with each product for specific requirements Installation Instructions Electrical Connections ATTENTION INSTALLER All electric wall ovens must be hard wired direct wired into an approved junction box A plug and receptacle is NOT permitted on these products DO NOT shorten the flexible conduit The conduit strain relief clamp must be securely attached to the junction box and the flexible conduit must be securely attached to the clamp If the flexible conduit will not fit within the clamp do not install the oven until a clamp of the proper size is obtained NOTE TO ELECTRICIAN The 3 power leads supplied with this appliance are UL recognized for connection to heavier gauge household wiring The insulation of these 3 leads is rated at temperatures much higher than the temperature rating of household wiring The current carrying capacity of the conductor is governed by the wire gauge and the temperature rating of the insulation around the wire WARNING Improper connection of aluminum house wiring to copper leads can result in an electrical hazard or fire Use only connectors designed for joining copper to aluminum and follow the manufacturer s recommended procedu
45. que los gabinetes y los revestimientos de la pared alrededor del horno puedan soportar las temperaturas hasta 200 F 93 3 C generadas por el horno gt A ADVERTENCIA La energ a el ctrica hacia la l nea de suministro del horno debe ser desconectada mientras se hacen las conexiones No hacer esto podr a resultar en lesiones graves e incluso provocar la muerte Requisitos el ctricos Este aparato debe abastecerse con la frecuencia y el voltaje adecuados y conectarse a un circuito el ctrico individual con conexi n a tierra con protecci n de un fusible o interruptor autom tico Consulte la placa de potencia ubicada en el marco del horno para determinar la potencia del producto Utilice el cuadro a continuaci n para determinar la protecci n m nima recomendada para el circuito el ctrico especializado Recomendable Potencia KW Potencia KW Tama o del circuito 240V 208V Especializado lt 4 8 KW lt 4 1 KW 20 Amp 4 9 KW 7 2 KW 4 3 KW 6 2 KW 30 Amp 7 3 KW 9 6 KW 6 3 KW 8 3 KW 40 Amp 7 KW 12 0 KW 8 4 KW 10 4 KW 50 Amp Requisitos el ctricos cont La placa de potencia se encuentra en la moldura lateral del horno el marco lateral frontal del horno o el marco frontal inferior del horno Ubicaci n de la placa de potencia Recomendamos que el cableado y la conexi n el ctrica de su horno los realice un electricista calificado Despu s de la instalaci n p da al electricist
46. re closely Place oven ona support to assist in connecting conduit Turn off the circuit breaker or remove fuses to the oven branch circuit With the oven supported on a table or platform in front of the cabinet opening connect the flexible conduit to the electrical junction box as shown below Position the conduit in such a manner that it will lie on top of the oven in a natural loop when the oven is installed You will need to purchase an appropriate strain relief clamp to complete the connection of the conduit to the junction box Junction Box Location Conduit Strain Relief Clamp not included must be used at Junction Box wW Installation Instructions New Construction and Four Conductor Branch Circuit Connection e When installing in new construction or e When installing in a mobile home or e When installing in a recreational vehicle or e When local codes do not permit grounding through neutral a Cut the neutral white lead from the crimp Re strip the neutral white lead to expose the proper length of conductor Ground Junction Box Cover Attach the appliance grounding lead green or bare copper in accordance with local codes If the residence grounding conductor is aluminum see WARNING on page 14 Connect the oven neutral white lead to the branch circuit neutral white or gray in accordance with local codes using a wire nut Conne
47. roondas Por Advantium o horno de microondas requisitos 2 5 1 cm M n NOTA El carril del medio que separa las dos aberturas pueden necesitar ser m s grande que el de 3 7 6 cm de m nimo que se muestra Siempre consulte las instrucciones para la instalaci n que se remiten con cada producto para obtener los requisitos espec ficos Instalaci n para el horno combinado Advantium o horno de microondas y de pared Para la instalaci n en combinaci n con un horno individual de pared utilice una caja de conexiones el ctricas separada Consulte las instrucciones de instalaci n del horno Advantium o del horno de microondas para obtener los requisitos de ese producto Un electricista autorizado debe realizar estas conexiones Todas las conexiones el ctricas debe cumplir con las normas del C digo El ctrico Nacional o los c digos locales vigentes Nota Instale el horno s lo con los modelos espec ficos enumerados en la etiqueta que se LEN ubica en la parte e 7 superior del horno oy 4 Horno individual de 27 68 6 cm Entre un horno Advantium o un horno de microondas y una gaveta de calentamiento Por Advantium o horno de microondas requisitos 2 5 1 cm Min 2 5 1 cm Min _ p de calentamiento iz requisitos Por gaveta NOTA Puede necesitarse una separaci n adicional entre los disyuntores Verifique para asegurarse de que los apoyos del horn
48. th aluminum wiring must be used Installation Instructions YW Pre Installation Checklist Door removal is not a requirement for ALL INSTALLATION INFORMATION installation of the product but is an ON THE FOLLOWING PAGES IS TO added convenience To remove the door BE USED FOR SINGLE AND DOUBLE OVEN INSTALLATION Y Open the oven door as far as it will go Remove packaging materials Push both hinge Hinge Check behind hinges and under locks down toward ps dr false bottom Remove labels on the the door frame A outside of the door plastic on trims to the unlocked and panel all tape around the oven position This may and any shipping screws securing require a flat blade the oven to the base pad screwdriver DO NOT LIFT THE DOOR BY THE HANDLE Y Y Place hands on both sides of the door and close the oven door to the removal position which is most of the way closed ASS Oven Racks Lift door up and out until the hinge arms Literature clear the slots Pack Open oven door and remove literature Hinge Clears Slot pack and oven racks NOTE The oven door is very heavy Be sure Remove Installation Instructions from you have a firm grip before lifting the oven literature pack and read them carefully door off the hinges Use caution once the before you begin door is removed Do not lay the door on its Be sure to place all literature Owner s handle This could cause dents or scratches Manua
49. utside edges As you slide the oven back pull the string so that the conduit will lie on top of the oven in a natural loop When you are sure the conduit is out of the way slide the oven 3 4 way back into the opening Remove the string by pulling on one end of the loop 16 b NOTE Before drilling the pilot holes make sure the oven is pushed as far back into the opening as it will go and centered Drill through the mounting holes top and bottom of the side trim for the 8 screws provided The screws must be a minimum of 1 4 6 mm from the front of the cutout Locations Hole ocations N AN WARNING Mounting screws must be used Failure to do so could result in the oven falling out of the cabinet causing serious injury Secure the oven to cabinet with screws provided NOTE If the cabinet is particle board you must use 8 x 3 4 particle board screws These may be purchased at any hardware store Installation Instructions Preparing for the Bottom Installing the Metal Trim Installation Bottom Trim a With oven installed take the bottom trim a Place the bottom metal trim centered over and center it on the bottom front edge of the pre drilled mounting holes Tape the the cabinet opening edges of the trim down to maintain the For 27 68 6 alignment Using the trim feces wie Lent as a template pa rat ae b Usin
50. y o lados podr a ser necesario si la unidad est ubicada entre gabinetes existentes Aseg rese de que est pegado firmemente ya que ste anclar el horno en el gabinete Plataforma de __ 3 4 1 9 cm de soporte 1 1 1 1 1 q 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 25 63 5 cm M n 25 1 4 64 1 cm Max 27 5 8 70 2 cm Min lt T 1 1 1 b mn Se RON A DEBE SOPORTAR 150 LIBRAS 68 Kg 1 7 Permita 1 2 5 cm para sobrepaso del horno por encima del horno et debajo del horno et 1 2 5 cm para sobrepaso del horno en los bordes laterals Debe equiparar la altura del z calo 22 55 9 cm M n Por encima de la plataforma de soporte 36 91 4 cm Altura t pica del gabinete 24 61 cm 4 10 2 cm Z calo t pico NOTA Este horno est aprobado s lo para instalarse bajo los modelos espec ficos indicados en esta unidad Gabinetes A Disyuntor para 27 68 6 cm Solamente para hornos individuales o dobles empotrados Sobre una gaveta de calentamiento Para los modelos JKS10 JKP30 JKP35 JKP55 JKP70 JKP75 PK916 PK956 ZEK938 ZEK958 solamente Horno individual de 27 Horno doble de 27 68 6 cm sobre una 68 6 cm sobre una gaveta de calentamiento gaveta de calentamiento Bloque estable contra la pared trasera para la gaveta de calentamiento requisitos

Download Pdf Manuals

image

Related Search

Related Contents

corrections du rallye - Archives municipales de Nantes  Samsung P2450H Наръчник за потребителя  OA10500 - Enerzone  Unit 5: Hemoglobin Testing  Tomato Analyzer User Manual Version 3  STARTUP MANUAL - Oriental Motor  APC NetShelter ES Enclosure 40U  Philips myKidsRoom Ceiling light 30501/53/16  Graco 312793H User's Manual  Servicing and Maintenance USER MANUAL TTX 350 / Ocelot  