Home

GE PTR Installation Guide

image

Contents

1. instructions do not purport to cover all details or variations in equipment nor to provide for every possible contingency to be met in connection with installation operation or maintenance Should further information be desired or should particular problems arise which are not covered sufficiently for the purchaser s purposes the matter should be referred to GE Lighting Solutions B WIRING Make all electrical connections in accordance with the National Electrical Code and any applicable local code requirements Verify that supply voltage is correct by comparing it to nameplate IF SINGLE VOLTAGE All single voltage ballasts are pre wired such that user need only connect the supply conductors IF MULTIVOLT 120 208 240 277 volts Connect the ballast lead with the insulated terminal to the desired voltage terminal as indicated on the ballast terminal nameplate IF MULTIWATT Multiwatt ballasts are available in various combinations of wattage See wiring instructions on wiring tag inside the luminaire e Optional Features such as fusing and photocontrols are voltage specific e Replace power fuses only with fuses of the same type and rating e When changing voltage on reconnectable units move only the lead with the insulated connector C LAMPS A CAUTION Risk of burn Allow lamp fixture to cool before handling INTERNAL GLASS REFRACTOR optional Install before lamp Find street side labeling and align acc
2. GE Lighting Solutions READ THOROUGHLY BEFORE INSTALLING A WARNING Risk of electric shock e Turn power off before servicing seeinstructions GENERAL This luminaire is designed for use in outdoor applications and must adhere to 25 C Max ambient temperature limita tion Install and maintain it according to the following recommendations A MOUNTING A CAUTION Unit will fall if not installed properly Follow installation instructions 1 Place fixture on appropriately sized tenon 2 Tighten fixture set screws to 18 to 22 ft lbs of torque 3 Install Lamp see section C of instruction sheet for lamp instructions OPTIONAL PHOTO CONTROL Ordered separately Rotate base casting so that PE window points away from other light sources SLIDE BRACKET GEH 5790 INSTRUCTIONS Patriarch Luminaire 4 Install refractor making sure that asymmetric refractors are properly oriented with respect to their house side or street side labeling 5 Tighten globe set screws to lightly contact globe 6 Wire unit see section B of instruction sheet for wiring instructions 7 Move slide bracket to closed position if it is in open position and if no cord is present See illustration 8 Close door securely PROTECTIVE SHIELD Move bracket to open position as shown for electrical cord passage Be sure bracket is in closed position when no electrical cord is in place These
3. TERMINAL BOARD GE Lighting Solutions e 1 888 MY GE LED e www gelightingsolutions com 1 888 69 43 533 GE Lighting Solutions is a subsidiary of the General Electric Company Evolve and other trademarks belong to GE Lighting Solutions The GE brand and logo are trademarks of the General Electric Company 2011 GE Lighting Solutions Information provided is subject to change without notice All values are design or typical values when measured under laboratory conditions 35 201578 Z9 07 01
4. ordingly Secure with supplied clamp FUSE BLOCK optional GROUND LINE or NEUTRAL Use only lamps specified on nameplate Observe lamp manufacturer s recommendations and restrictions on lamp operation particularly ballast type burning position etc LAMP TIGHTNESS The lamp should be securely inserted to NEMA EEI specified torque of 35 inch pounds which is best achieved by very firmly tightening to insure applica tion of sufficient torque Tightening must be sufficient to fully depress and load center contact of socket NOTE Use of lubricants on lamp base or sockets can cause rapid lamp failure and voids fixture warranty D MAINTENANCE AND CLEANING It will occasionally be necessary to clean the refractor to maintain light levels Frequency of cleaning will depend on ambient dirt level and minimum light level which is acceptable to the user The refractor should be washed in a solution of warm water and mild nonabra sive household detergent rinsed with clean water and wiped dry The light output of a luminaire is dependent on the age of the lamp In applications where the light level is critical it may be desirable to replace lamps before they burn out The lamp manufacturer can provide data showing how the lamp light output decreases with use SOCKET Lamps should be tightened to 35 inch pounds torque BALLAST CANNISTER For multivolt ballasts see above instructions SIMPLEX RECEPTACLE optional

Download Pdf Manuals

image

Related Search

Related Contents

XR2v3  Smeg KSEIR60 cooker hood  Philips Wireless notebook mouse SPM7800  Manuale Utente      KYO300 User Manual (English) v3.0  Specifications - Anytime Trailer Rental  Operation manual for the Carbide C50-C75  MANUAL DEL USUARIO - Besøg masterpiece.dk  

Copyright © All rights reserved.
Failed to retrieve file