1. Solutions e 1 888 MY GE LED e www gelightingsolutions com 1 888 69 43 533 GE Lighting Solutions is a subsidiary of the General Electric Company Evolve and other trademarks belong to GE Lighting Solutions The GE brand and logo are trademarks of the General Electric Company 2011 GE Lighting Solutions Information provided is subject to change without notice All values are design or typical values when measured under laboratory conditions 35 201578 47 6 00
2. provided Remove the electrical disconnect from the mounting hub and connect electrically as stated for conduit mounting NOTE Threads on the ballast housing to ac cept the above mountings are factory lubricated with General Electric Versalube G322L Additional lubricant of the same type may be applied if necessary BALLAST HOUSING Thread the ballast housing onto the hub The electrical disconnect will automatically mate after five threads have engaged Continue engaging until the housing is tightly threaded onto the hub and then tighten the set screw at the bottom of the hub LAMP INSTALLATION CAUTION Risk of burn e Allow lamp fixture to cool before handling Disconnect the power supply circuit before relamping Loosen the set screw near the bottom edge of the ballast housing Unthread the glass globe support ring which threads into the ballast housing To assist in removing this globe ring a screw driver can be inserted in the pry slots or the globe ring can be loosened by lightly tapping on the globe ring ribs Use only lamps specified on nameplate Observe lamp manufacturer s recommendations and restric tions on lamp operation particularly ballast type burning position etc Damage may occur to the fixture if the lamp is inserted while power is on or if the lamp is not tight in the socket when power is applied LAMP TIGHTNESS The lamp should be securely inserted to the NEMA EE I specified torque of
3. 35 inch pounds which is best achieved by very firmly tightening to insure application of sufficient torque Tightening must be sufficient to fully depress and load the center contact of the socket After lamp is installed rethread globe ring into ballast housing until it firmly seats Tighten set screw WARNING GLOBE IS TEMPERED GLASS DO NOT SCRATCH OR CHIP EXTERNAL REFLECTORS A reflector if used is attached to the bottom of the globe ring with the three screws provided If a globe guard is on the unit the reflector is attached using the same screws that hold the guard These screws need only be loosened since the reflector is provided with keyhole slots If an angle reflector is used orient the reflector with respect to the three screws so that the main light output is near the desired direction After loosening the set screw the globe ring can then be slightly rotated to complete the reflector orientation Then retighten the set screw MAINTENANCE It will occasionally be necessary to clean the optical assembly in order to maintain the light level Frequency of cleaning will depend on the dirt level in the user s facility and the minimum light level which is acceptable to him The reflector should be cleaned with any suitable non abrasive solution of water and soap or detergent Residual cleanser should be removed by clean water rinsing The glassware may be cleaned with any conventional glass cleanser GE Lighting
4. GE Lighting Solutions READ THOROUGHLY BEFORE INSTALLING GENERAL This luminaire is designed for application in hazardous location environments Risk of electric shock e Turn power off before servicing see instructions Make all electrical connections in accordance with the National Electrical Code and any applicable local code requirements THE OPERATING TEMPERATURE T CODE LISTED FOR THIS LUMINAIRE IS BASED ON THE FOLLOWING BULB SIZES USE OF OTHER THAN THESE MAY RESULT IN A HIGHER OPERATING TEMPERATURE AND COULD RESULT IN A HAZ ARDOUS CONDITION LAMP TYPE WATTAGE BULB SIZE HIGH PRESSURE SODIUM 70 100 150 ED 23 1 2 HIGH PRESSURE SODIUM 250 400 ED 18 METAL HALIDE MERCURY 175 250 ED 28 METAL HALIDE MERCURY 400 ED 37 CAUTION Check the operating temperature limits marked on the ballast assembly prior to installa tion to be sure it conforms to the environmental temperature restrictions and NEC classifications WARNING TO PREVENT IGNITION OF HAZARD OUS ATMOSPHERES DISCONNECT THE SUPPLY CIRCUIT FROM THE LUMINAIRE BEFORE RELAMP ING REMOVING OR PERFORMING ANY MAINTE NANCE UNPACKING The ballast assembly and mounting fittings have been properly packed in separate cartons so that no parts should have been damaged during transit Remove packing materials used to protect threads and inspect Do not attempt to assemble or use parts with damaged threads Verify that supply voltage is correct by comparin
5. g it to nameplate GEH 3772E INSTRUCTIONS POWReGARD LUMINAIRE INSTALLATION Ay CAUTION Unit will fall if not installed properly e Follow installation instructions MOUNTING CONDUIT Take the mounting hub and remove the electrical disconnect from it Thread the mounting hub onto the conduit five threads minimum and tighten the set screw Connect the ground lead to the screw provided in the mounting hub Connect the supply wires to the electrical disconnect according to the color coding labels if applicable Refasten the disconnect into the mounting hub See Figure A Figure A MOUNTING STANCHION AND WALL BRACKET For the stanchion arm mount arm onto the conduit five threads minimum and tighten the set screw For the wall bracket attach bracket to the support surface through the These instructions do not purport to cover all details or variations in equipment nor to provide for every possible contingency to be met in connection with installation operation or maintenance Should further information be desired or should particular problems arise which are not covered sufficiently for the purchaser s purposes the matter should be referred to GE Lighting Solutions four clearance holes provided Remove the electrical disconnect from the mounting hub and connect electrically as stated for conduit mounting MOUNTING SURFACE Attach the surface mounting box to the support surface through the four clearance holes