1. GE Lighting e 1 888 MY GE LED 11 888 69 43 533 www gelighting com GE Lighting est une filiale de la General Electric Company Evolve ainsi que la marque et le logo GE sont des marques commerciales d pos es de la General Electric Company 2013 GE Lighting Les informations fournies ici sont susceptibles de changer sans pr avis Toutes les donn es sont des valeurs de conception ou caract ristiques lors de leur mesure en conditions de laboratoire 35 201578 197 R v 09 11 13 French
2. side faces the proper direction e Tighten the top set screw on the pipe fitting e Fit the cupola onto the top housing of the fixture e Tighten the 3 cupola screws Customer Pendant Apply pipe sealant to this joint Cupola Set Screw Pipe Fitting Cupola Screws 3 WIRING e NOTE Make all electrical connections in accordance with the National Electrical Code and any applicable local code requirements e NOTE Verify that supply voltage is correct by comparing it to nameplate Standard Mounting e Remove cover at base of unit and connect all 3 power leads to the terminal block e Replace cover Pendant Mounting e Remove one screw to open the top of the fixture Allow the bottom to hang from it s hinges e Pull the wires into the top housing e Connect all 3 power leads to the terminal block in the top housing e Close top and replace the latch Latch Screw WARNING Risk of injury LED light source achieves full intensity immediately upon being powered on Do not look directly at LED light source while energized during install PHOTOELECTRIC CONTROL STORAGE Not Available with Pendant Mount e Prior to installation units should NOT be stored e When a photoelectric control is used the photoelectric outside in corrugated boxes cardboard boxes alone receptacle should be oriented so that the word North is directed toward the true north direction This can be e
3. GE Lighting Installation Guide GEH 6005A Evolve LED Post Top Salem EPST BEFORE YOU BEGIN Read these instructions completely and carefully Save these instructions for future use A WARNING Risk of electrical shock Disconnect power before servicing or installing product A WARNING Risk of injury or damage Unit will fall if not installed properly Follow installation instructions CAUTION Risk of injury Wear safety glasses and gloves during installation and servicing This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation This Class A RFLD complies with the Canadian standard ICES 003 Ce DEFR de la classe A est conforme la NMB 003 du Canada ote This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is like
4. Until installation all units should be placed in a easily done by seating a photoelectric control into the covered dry storage area The storage area should receptacle lifting upward on the photoelectric control not exceed 40 C 40 F to 50 C 122 F which will lift the photoelectric receptacle also and This can be preferably in a roofed area or with a rotating them clockwise until the word North is tarp that is secured in such a way to keep water directed toward the true north direction Lower the off of the corrugated boxes cardboard boxes photoelectric control and receptacle to firmly seat them into position No tools are required to make this orienting adjustment e Alternatively the photoelectric receptacle can be oriented before the photoelectric control is installed This is done by lifting up on the rim of the photoelectric receptacle and rotating it until the word North is directed toward the true north direction Lower the photoelectric receptacle to firmly seat it in this position Install the photoelectric control e Because of the shielding of the cupola window by the cupola top it may be necessary to adjust for an earlier turn on time of the photoelectric control MAINTENANCE CLEANING WARNING Risk of electric shock Make certain power is off before attempting any maintenance e To maintain high efficiency of the lens occasional cleaning of the outer lens surface may be needed wi
5. ale imm diatement apr s sa mise sous tension Durant l installation ne regardez pas directement la source lumineuse DEL lorsqu elle est allum e COMMANDE PHOTOELECTRIQUE Non disponible avec montage suspendu Si une commande photo lectrique est utilis e son r ceptacle doit tre orient pour que le mot North soit dirig vers le nord v ritable Pour cela enfoncez la commande photo lectrique dans le r ceptacle puis levez la commande et le r ceptacle les deux se soul vent ensemble et faites les tourner ensemble dans le sens horaire jusqu ce que le mot North soit tourn vers le nord v ritable Abaissez ensuite la commande photo lectrique et le receptacle pour les enfoncer solidement leur place Aucun outil n est n cessaire pour effectuer ce r glage d orientation Si vous le pr f rez le r ceptacle de la commande peut tre orient avant d installer la commande Pour cela levez le contour du r ceptacle et faites le tourner jusqu ce que le mot North soit align avec le nord v ritable Abaissez ensuite le r ceptacle et enfoncez le sa place Installez ensuite la commande photo lectrique e cause de l ombre que fait la coupole sur la vitre il pourrait tre n cessaire de r gler le luminaire pour que la commande photo lectrique produise un allumage plus t t ENTRETIEN ET NETTOYAGE AVERTISSEMENT Risque de choc lectrique Avant de commencer toute op ration d
6. entretien assurez vous que l alimentation lectrique est coup e Pour conserver l efficacit de la lentille nettoyez p riodiquement la surface ext rieure de la lentille la fr quence des nettoyages d pendra des conditions locales Utilisez un savon doux ou un d tergent essentiellement neutre ayant un pH d environ 6 8 sans abrasif et sans hydrocarbure chlor ou aromatique Lavez fond avec la solution de nettoyage en utilisant un chiffon doux Rincez avec de l eau froide et propre puis essuyez O ENTREPOSAGE Avant leur installation les luminaires ne doivent PAS tre entrepos s l ext rieur dans de simples bo tes en carton Jusqu leur installation tous les luminaires doivent tre conserv s dans un lieu de stockage couvert et sec La tem p rature du site de stockage doit se situer entre 40 C et 50 C 40 F et 122 F Conservez les pr f rablement sous un toit ou sous une b che install e solidement de fa on ce que l eau ne puisse atteindre les bo tes en carton Ces instructions n ont pas pour but de couvrir tous les d tails et toutes les variantes de l quipement ni de r pondre tous les impond rables possibles en relation avec l installation le fonctionnement et l entretien Si vous d sirez plus d informations ou si des probl mes particuliers surviennent qui ne sont pas couverts suffisamment pour les besoins de l acheteur le sujet doit tre soumis GE Lighting
7. ly to cause harmful interference in which case the user will be required to correct the interference at his own expense imagination at work Pendant Mounting e This luminaire is designed for outdoor lighting service and should not be used in areas of limited ventilation or in high ambient temperature enclosures e Best results will be obtained if installed and maintained according to the following recommendations UNPACKING e This luminaire has been properly packed so that no parts should have been damaged during transit e Inspect to confirm MOUNTING WARNING Risk of injury or damage Unit will fall if not installed properly Follow installation instructions Standard Mounting e This luminaire is provided with means for mounting on 3 inch 76mm max outside diameter pole tops e Feed the power supply leads through the slipfitter wire access hole as the fixture is installed on the pole e Orient canopy screw or latch toward street and level by adjusting the 3 screws and tighten e Caution Tighten screws to 15 20 ft lbs 20 27 N m e Remove shipping ties from wire way in the rear upright Pendant Mounting e Use 1 1 4 inch pipe for Pendant e Insert the pendant pipe through the cupola e Apply an appropriate pipe sealant to the end of the pendant pipe e Turn the pendant pipe into the 1 1 4 inch pipe fitting on top of the fixture e Orient the fixture so that the house
8. pendu Ce luminaire a t con u pour une utilisation l ext rieur et ne doit pas tre employ sur un site mal ventil ni dans un endroit clos dont la temp rature ambiante peut tre lev e Pour obtenir des performances optimales il doit tre install et entretenu conform ment aux recommandations suivantes D D BALLAGE e Ce luminaire a t soigneusement emball pour qu aucune pi ce ne subisse de dommages durant le transport e Proc dez une inspection pour vous en assurer ASSEMBLAGE AVERTISSEMENT Danger de blessure et de dommage mat riel L appareil tombera au sol s il est mal install Suivez les instructions d installation Montage standard e Ce luminaire est livr avec ce qu il faut pour un montage sur le dessus d un poteau ayant un diam tre ext rieur ne d passant pas 3 po 76 mm e Faites passer les fils conducteurs dans le trou du joint coulissant lorsque le luminaire est install sur le poteau e Orientez la vis ou le verrou sur le bord du toit vers la rue puis r glez le niveau avec les 3 vis pr vues cet effet et serrez e Mise en garde Serrez les vis avec un couple de 15 20 Ib pi 20 27 N m e Enlevez les attaches d exp dition dans le passage de fils sur le montant arri re Montage suspendu e Utilisez un tuyau de 1 1 4 po pour installation suspendue e Ins rez le tuyau descendant dans la coupole e Appliquez un enduit d tanch it appropri pou
9. r tuyaux sur l extr mit du tuyau descendant e Tournez le tuyau descendant dans le raccord de tuyau de 1 1 4 sur le dessus du luminaire e Orientez le luminaire afin que le c t maison soit tourn dans le bon sens e Serrez la vis d arr t sup rieure sur le raccord de tuyauterie e Ins rez la coupole sur le bo tier sup rieur du luminaire e Serrez les 3 vis de la coupole Tuyau descendant du client Appliquer de l enduit d tanch it sur ce joint Coupole Vis d arr t Vis de coupole 3 Raccord de tuyauterie CABLAGE e REMARQUE Toutes les connexions doivent tre conformes aux normes lectriques nationales et la r glementation locale en vigueur code lectrique du Canada et r glementation locale applicable e REMARQUE Assurez vous que la tension lectrique est ad quate en v rifiant la plaque signal tique Montage standard e Enlevez le couvercle sur la base du luminaire puis connecter les 3 fils d alimentation au bloc de bornes e R installez le couvercle Montage suspendu e Enlevez une vis pour ouvrir le dessus du luminaire Laissez le fond suspendu sur ses charni res e Tirez les fils dans le bo tier sup rieur e Connectez les 3 fils lectriques sur le bloc de bornes du boitier sup rieur e Fermez le dessus et r installez le verrou Vis du verrou Verrou AVERTISSEMENT Danger de blessure La source lumineuse DEL atteint son intensit maxim
10. th frequency dependant on local conditions e Use a mild soap or detergent which is essentially neutral pH pH approximately 6 to 8 non abrasive and which contains no chlorinated or aromatic hydrocarbons e Wash thoroughly using a soft cloth e Rinse with clean cold water and wipe dry These instructions do not purport to cover all details or variations in equipment nor to provide for every possible contingency to be met in connection with installation operation or maintenance Should further information be desired or should particular problems arise which are not covered sufficiently for the purchaser s purposes the matter should be referred to GE Lighting GE Lighting 1 888 MY GE LED e www gelighting com 1 888 69 43 533 2013 GE Lighting Evolve and the GE brand and logo are trademarks of the General Electric Company Information provided is subject to change without notice All values are design or typical values when measured under laboratory conditions 35 201578 197 Rev 09 11 13 English GE Lighting Guide d installation GEH 6005A Luminaire de sommet de poteau DEL Evolve Salem EPST AVANT DE COMMENCER Lisez attentivement toutes ces instructions AVERTISSEMENT Risque de choc lectrique D connectez l alimentation lectrique avant d installer ou r parer ce produit AVERTISSEMENT Danger de blessure et de dommage mat riel L appareil tombera au sol s il est mal install S
11. uivez les instructions d installation AATTENTION Danger de blessure Lors de l installation et de la r paration de cet appareil porter des lunettes et des gants de s curit Cet appareil est conforme aux exigences de la partie 15 des r gles de la FCC Son utilisation est sujette aux conditions suivantes 1 cet appareil ne doit pas causer d interf rences nuisibles 2 cet appareil doit accepter toutes les inter f rences re ues y compris celles pouvant causer un fonctionnement ind sir able Ce DEFR de la classe A est conforme la norme NMB 003 du Canada Remarque Cet appareil a t test et reconnu conforme aux limites tablies pour les appareils num riques de classe A selon la partie 15 des r gles de la FCC Ces limites sont con ues pour assurer une protection raisonnable contre les interf rences nuisibles dans un environnement commercial Cet appareil g n re utilise et met de l nergie sous forme de radiofr quences de sorte que si son installation et son utilisation ne sont pas conformes la notice d utilisation il peut tre la cause de parasites nuisibles aux communications radio L utilisation de cet quipement dans une zone r sidentielle risque for de causer des interf rences nuisibles auquel cas l utilisateur devra corriger le probl me ses propres frais imagination at work Conservez ces instructions pour r f rence future Montage standard Montage sus