1. Fit canopy over stud of crossbar then screw cable from the luminaire to the matching colored coupler onto stud wires from the driver enclosure Connect both green wires to the grounding screw Refer to the EP DKIT400UV and EP DKIT400UD LED Driver Installation Instructions for more information Squeeze tip to adjust O To adjust height and to level a fixture squeeze the QO Optional For an improved appearance electrical tip of the gripper and pull the suspension cable to wire can be tie wrapped to the suspension wire the desired height Clip the cable with cable cutters to finish the appearance Optional Mounting Method Connecting Suspended Fixtures in Series Canopy set without power cable a Canopy sets with power cable N 1 For multiple units installed in series all canopy sets will have a power cable except the last canopy Disconnect suspension wire Bracket Y shape suspension wire On the 1st luminaire disconnect the right side Attach a bracket to each end of the Y shape suspension wire and Y shape suspension wire suspension wire using washer spring washer Then on the 2nd luminaire disassemble the and M8 nuts Screw torque should be between left side Y shape suspension wire this one will 15 3 0 8kq f not be used Squeeze tip to adjust O Join 1st and 2nd luminaires together by fastening Reattach suspension wire to Y shape suspension the brackets on
2. 012 GE Lighting Solutions LLC Information provided is subject to change without notice All values are design or typical values when measured under laboratory conditions INDO49 121712
3. GE Installation Guide Lighting Solutions Lumination LED Luminaires Series EP14 Lutron TVI LMF 2A Eco BEFORE YOU BEGIN Read these instructions completely and carefully WARNING AVERTISSEMENT RISK OF ELECTRIC SHOCK RISQUES DE DECHARGES ELECTRIQUES e Turn power off before inspection installation or removal e Coupez l alimentation avant d inspecter installer ou de retirer l unit e Properly ground electrical enclosure e Assurez vous de correctement mettre la terre le bo tier d alimentation RISK OF FIRE lectrique e Follow all NEC and local codes RISQUES D INCENDIE e Use only UL or IEC approved wire for input output connections e Respectez tous les codes NEC et codes locaux Minimum size 18 AWG 0 75mm e N utilisez que des fils approuv s par UL pour les entr es sorties de connexion Taille minimum 18 AWG 0 75mm Save These Instructions Use only in the manner intended by the manufacturer If you have any questions contact the manufacturer Prepare Electrical Wiring Electrical Requirements e The LED driver must be supplied with 120 277 VAC 50 60 Hz and connected to an individual properly grounded branch circuit protected by a 15 or 20 ampere circuit breaker Use Min 75 C supply conductor Grounding Instructions e The grounding and bonding of the overall system shall be done in accordance with National Electric Code NEC Article 600 and local codes imagination at work Electrical Connec
4. ace with twist on wire caps cover and screw down M4 screws and lock washers Connect EcoSystem bus wires to the two purple Make sure screws are tight and cover is secured Lutron connectors Link E1 and E2 Define Distance Between Canopy Sets Single unit installation scenario SS TE ee as 1179mm 46 4 in distance between canopy sets Luminaire e Multiple units in series installation scenario 1193mm 47 in 1207mm 47 5 in 1207mm 47 5 in 1207mm 47 5 in 1193mm 47 in a _ q 7 1st luminaire 2nd luminaire 3rd luminaire 4th luminaire 5th luminaire Distance between canopy sets for left and right luminaires 1193mm 47 in Distance between canopy sets for luminaires in the middle 1207mm 47 5 in Example To install five units in series the distance between canopy sets for the 1st left and 5th right luminaire is 1193mm 47 in and the distance between canopy sets for the 2nd 3rd and 4th middle luminaires is 1207mm 47 5 in Unit Installation Crossbar Carefully unpack unit from its packaging Properly Attach crossbar to junction box in ceiling with two inspect for defects before installing Wear work 1 4 inch screws Repeat on other side gloves to prevent dirt and oil from being transferred to the luminaire ae Cable coupler a Suspension cable 3 Connect the black line and white neutral wires O
5. the modified Y shape suspension wire To adjust height and to level a fixture squeeze wire from Step 9 Fasten brackets using four the tip of the gripper and pull the suspension cable M8 screws Screw torque should be between to the desired height Clip the cable with cable 15 3 0 8kg f cutters to finish the appearance Maximum Driver Remote Mounting Distance Supply Wire Gauge Wire Length 18 AWG 0 82 mm 59 0 ft 18 m 16 AWG 1 31 mm 98 4 ft 30 m 14 AWG 2 08 mm 154 2 ft 47 m 12 AWG 3 31 mm 249 3 ft 76 m Includes fixture s 6 6 ft 2 0 m power cord Specifications Input Voltage VAC 120 277V Input Power W 55W Input Frequency Hz 50 60 Hz Power Factor gt 0 9 THD lt 20 Control 0 10V amp DALI Ceilings Cable Suspension System Warranty 5 years Dimensions 47 5 in x 11 8 in x 1 38 in 1206 mm x 299 mm x 35 mm Light Fixture Weight 14 3 Ibs 6 5 kg Environmental Operating Temperature Range 10 C to 25 C Environmental Humidity non condensing 20 to 80 Non condensing dry location rated Environmental Storage Temperature Range 40 C to 60 C Conforms to the following standards cus GE Lighting Solutions e 1 888 MY GE LED e www gelightingsolutions com 1 888 69 43 533 GE Lighting Solutions LLC is a subsidiary of the General Electric Company Lumination is a trademark of GE Lighting Solutions LLC The GE brand and logo are trademarks of the General Electric Company 2
6. tions Wiring Diagram White White Orange Black Lutron Interface Violet White DALI PSU lt GND Green Yellow GND Violet DALI O 10V lt Neutral White N Grey 0 10V Switched Hot Out Line Black lt Line Black Constant Hot In Neutral White lt EcoSystem Link E1 EcoSystem lt EcoSystem Link E2 Digital Link Carefully unpack unit from its packaging Install Gently place enclosure cover close to the driver driver enclosure to a suitable structural member enclosure Follow wiring diagram and insert striped using two 4 20 screws wires into Lutron interface connector as described Risk of damage Make sure driver enclosure is not in next step installed where wires can be cut by sharp edges a Grey c Green yellow d White f e Orange Black ie EcoSystem line Connect Driver wires to Lutron interface as follows Push out appropriate size knockout tabs and install a Driver 0 10V grey wire to Lutron grey connector approved conduit connectors for both the AC and b Driver 0 10V violet wire to Lutron violet connector EcoSystem lines c One green yellow wire to Lutron green connector d One Driver white wire to Lutron white connector e Driver orange wire to Lutron orange connector Connect AC line to black white and green wires QO After completing connections replace enclosure from Lutron interf