1. GE  Lighting Solutions       GEH 3894C    INSTRUCTIONS  Ballast and Optical Asembly for    Versaglow    Conserva   150  400 and Minimite            CONSERVA 150  400  Cis  C4s       SI   MPM 3PR  MPM 3PRW       ES  MPM 3PF    READ THOROUGHLY BEFORE INSTALLING             A WARNING    Risk of electric shock  e Turn power off before servicing    see instructions                         GENERAL   The ballast assembly  optical assembly  and hanging hardware are separately packaged  Check to insure that  unit is not damaged and verify that correct material has been received    If the luminaire you ordered has a polycarbonate refractor  please pay particular attention to the following  statement    All polycarbonates and articles made from polycarbonates  will yellow with time  The rate of yellowing is  determined by the specific material  any additives and coatings  as well as the optical temperature and exposure to  ultraviolet  UV  light    This yellowing can reduce the light output and impact resistance of products made from polycarbonates  In no  ease should the maximum voltage recommendations listed for the luminaire be exceeded  Contact factory for more  information     MOUNTING             CAUTION    Unit will fall if not installed properly  e Follow installation instructions                         TO ATTACH LUMINAIRE TO SURFACE MOUNTED HANGING HARDWARE MPM C  Remove wiring compartment cover plate from hanging hardware  Slide luminaire extrusion fully into hanger  arna AN 
2. Replace cover plate  The cover plate is necessary to seal wiring chamber and lock luminaire into hanging  ardware     TO ATTACH LUMINAIRE TO RIGID CONDUIT HANGING HARDWARE  MPM 3PRW  For Wet Location  Enclosed Minimite MMI   Minimite MML   and Conserva 150 C15  only     MPM 3PR  Remove cover plate from hanging hardware  Slide luminaire extrusion fully into hanger extrusion  Replace cover  plate  Cover plate is necessary to seal wiring chamber and lock luminaire into hanging hardware     TO ATTACH LUMINAIRE TO NON RIGID CONDUIT MPM 3PF   Use same assembly procedure as for above hanging hardware  If an adjustment is necessary to center weight  of luminaire in non rigid pendant mounting  slightly loosen top screw and slide hub in relation to luminaire until  luminaire hangs vertically  Re tighten top screw     TO ATTACH LUMINAIRE TO JUNCTION BOX MOUNTED HANGING HARDWARE MPM OBC  Slide luminaire extrusion full into hanger extrusion  When extrusions are properly engaged  a    click    should be  heard as spring clip rides over cast protrusion and snaps into place   To remove luminaire  insert screwdriver blade into hole in spring clip and pull gently downward on handle lifting  clip over cast protrusion  Grasp luminaire in both hands and withdraw it from hanger     TO ATTACH LUMINAIRE TO WALL BRACKET MPM WW TO WALL BRACKET  MPM W3TFW STANCHION MOUNT MPM 5ASW    MINIMITE OPTICALS ONLY    Remove cover plate of mounting bracket  Slide luminaire extrusion into hanger extrusion and rep
3. aring it to nameplate   Do not remove insulated connectors from wires not needed for required voltage connection     When changing voltage on reconnectable units  move only the lead with the insulated connector     IF SINGLE VOLTAGE   All single voltage ballasts are pre wired such that user need only connect the supply conductors   IF MULTIVOLT  120 208 240 277 volts     Connect the ballast lead with the insulated terminal to the desired voltage terminal as indicated on the  ballast terminal nameplate     IF MULTIWATT     Multiwatt ballasts are available in various combinations of wattage  See wiring instructions on wiring tag  inside the luminaire     Replace reflector plate by reversing above procedure   Note  Recessed area of plate must close off area around socket  Do not flip over when reinstalling      Note  For multivolt on switched quartz units  replace reflector plate with starred hole above capacitor     LAMP INSTALLATION    Use only lamps specified on nameplate  Observe lamp manufacturer s recommendations and restric   tions on lamp operation  particularly ballast type  burning position  etc     Lamp Tightness  The lamp should be securely inserted to NEMA EEI Specified torque or 35 inch pounds   which is best achieved by very firmly tightening to insure application of sufficient torque  Tightening must be  sufficient to fully depress and load center contact of socket     Lamp Tightness   Medium Base Lamp  The lamp should be tightened to a light firmness sufficient 
4. desired or should particular problems arise which are not covered sufficiently for the purchaser s purposes  the matter should be referred to GE Lighting Solutions     GE Lighting Solutions e 1 888 MY GE LED e www gelightingsolutions com  1 888 69 43 533    GE Lighting Solutions is a subsidiary of the General Electric Company  Evolve and other trademarks belong to GE Lighting Solutions  The GE brand and logo are trademarks of the General Electric Company      2011 GE Lighting Solutions  Information provided is subject to change without notice  All values are design or typical values when measured under laboratory conditions     35 201578 C4  1 00     
5. lace cover plate   The cover plate is necessary to seal wiring chamber and lock luminaire into wall bracket     INSTALLING OPTICAL ASSEMBLY    NOTE  For units with clampbands  assemble refractor and reflector with clampband and hardware provided     CAUTION  DO NOT REST A COMPLETE LUMINAIRE ON THE REFRACTOR  THIS REFRACTOR IS A PRECISION  OPTICAL INSTRUMENT AND WILL NOT SUPPORT THE FULL WEIGHT OF THE LUMINAIRE     VERSAGLOW 150  250  CONSERVA 150  400   After hanging hardware  ballast assembly  and lamp have been properly installed according to their instructions   hook latches on ballast assembly to tabs on optical assembly  Snap retaining latches to upward position to complete  installation     MINIMITE    After hanging hardware  ballast assembly  and lamp have been properly installed according to their instructions   pull down three latches and slip spring loops over hooks  In the case of hook  which acts as a hinge  the flat spring must  be bent slightly to allow loop to be released        MPM OBC       MMI MML       MPM SASW MPM W3TFW    MPM WW    WIRING    For certain voltages  open unit through reflector plate by loosening three screws  rotating plate with a  small screwdriver in slot provided and lifting plate   On some units  unit is opened by completely removing  screws  Wire per instructions     Make all electrical connections in accordance with the National Electrical Code and any applicable local  coderequirements     Verify that supply voltage is correct by comp
6. to  depress the center contact     SWITCHED QUARTZ    The switched quartz socket is secured for shipping inside main lamp socket  Remove  align and snap into  starred hole provided in reflector plate  Install quartz lamp  not provided   When reflector plate is removed for  multivolt units replace with starred hole above capacitor     MAINTENANCE AND CLEANING       CAUTION    Risk of burn  e Allow lamp fixture to cool before handling                               It will occasionally be necessary to clean outside of refractor to maintain light levels  Frequency of  cleaning will depend on ambient dirt level and minimum light levels acceptable to user  The refractor should  be washed in a solution of warm water and any mild  non abrasive household detergent  Wipe with soft cloth  or brush  Rinse in cool  clear water  Should the optical assembly become dirty on inside  clean in above manner   and replace any damaged gasket  Use of abrasive cleaners will shorten life of refractor and refractor    The light output of a luminaire is also dependent on age of lamp  In applications where light level is critical  it may be desirable to replace lamps before they burn out  The lamp manufacturer can provide data showing  how lamp light output decreases with use     These instructions do not purport to cover all details or variations in equipment nor to provide for every possible contingency to be metin connection with installation  operation or maintenance  Should  further information be 
    