Home

GE BL Series Installation Guide

image

Contents

1. Use only in the manner intended by the manufacturer If you have any questions contact the manufacturer Prepare Electrical Wiring BL Series 4 Wide End Covers SKU 85598 Electrical Requirements e BL Series CE Continuous Leader Cable 1 10V SKU 85601 e The LED driver must be supplied with e BL Series CE Continuous Leader Cable DALI SKU 85675 120 240 VAC 50 60 Hz and connected to an individual properly grounded branch circuit Use min 600V 75 C supply conductor Grounding Instructions e The grounding and bonding of the overall system shall be done in accordance with IEC and local codes imagination at work Wiring Diagrams Optional Installation 1 10 Volt Dimming or DALI Lighting Controller Follow diagram A for 0 10 V or diagram B for DALI Line black ine Line black line Neutral white Neutral white Neutral PSU 1 10V Ground green 1 10V g Ground PSU Neutral Ground green Groin 1 10 violet na DALI DALI 1 violet as DALI 1 10 grey DALI 1 10V DALI 2 orange DALI 1 10V O 1 10V wiring diagram O DALI wiring diagram Preliminary Electrical Connections Dimming line optional Line in connector First unit only accessory 1 Loosen cable gland nuts to insert AC line Optionally 2 Connect the AC line and dimming wires to the insert dimming line into smaller cable gland terminal block of the line in connector acce
2. to be trimmed see Step 2 making sure the diffuser with the green protective film is placed on the bottom remove film first The last diffusers will need to be trimmed see Step 2 Place diffuser to be trimmed on a clean surface Position score over table edge and carefully snap Apply masking tape over cutting area Score plastic off end Remove tape file edge and clean Install with utility knife to about 50 of plastic thickness diffuser as instructed in Step 1 Troubleshooting Symptom Solution Luminaire does not light e Check input voltage and check power supply input output connections e Check circuit breaker Luminaire is dim e Dimming wire connection shall be checked and if connection is not proper reconnect it If wire is harmed replace it with an intact one Also check that dimming wires are not in short circuit Luminaire is blinking e Ensure power supply temperature does not exceed its maximum rating e Refer to the tc point located on power supply Luminaire does not dim e Check dimming wire connection Luminaires will not turn on Check that the color of the supply side wires match the color of the wires they are connected to e Check that the LED driver connector is fully engaged to the LED light engine connector e Check that the LED light engines are connected at the junction between the two luminaires Luminaire on through e Check that the through wiring connector from the previous fixture in the linea
3. GE Installation Guide Lighting Lumination LED Luminaires BL Series Continuous Run Option BEFORE YOU BEGIN Read these instructions completely and carefully AX WARNING AVERTISSEMENT RISK OF ELECTRIC SHOCK RISK OF FIRE e Turn power off before inspection installation or removal e Follow all IEC and local codes e Properly ground electrical enclosure e Use only IEC approved wire for input output connections Minimum size 14 AWG 0 75mm Save These Instructions Provided in the Package Luminaire without end covers Universal mounting brackets 4 pieces 3x12mm screws for mounting bracket installation 8 pieces 3 wingnut 8 pieces Importa nt Ceiling ori oe for grid and bracket fixing 4 pieces e 120 127V 60Hz maximum 33 meters of luminaires various unit e M4x16mm screw for bracket to bracket fixing 2 pieces can be connected on a single through wiring run 4 nut for bracket to bracket fixing 2 pieces e 220 240V 50 60Hz maximum 64 meters of luminaires can be Primary diffuser connected on a single through wiring run e Optional low glare diffuser with protective foil e Please see technical data sheet for electrical properties to ensure e Joiner pins 2 pieces safe installation e Under any circumstance maximum driver current through connected fixtures shall not exceed 12 A Tools and Com ponents Required For end cover install Philips headed screwdriver e For bracket to bracket fixing 7mm wrench or socket
4. m from ends Do star washer under one of the top screws to ensure not tighten wingnuts yet ground continuity Note The luminaires between the opening and closing units do not require end covers End cover No end covers End cover Middle luminaire s First luminaire up to 8 units Last luminaire ee J ins A J Pins A O Place luminaires into ceiling grid Carefully align pins of one luminaire with grooves of next luminaire then push them completely together taking care not to pinch wires Note A rubber mallet may be required to complete this step Hammer the luminaires only on the top edge not the bottom One safety screw per bracket is mandatory additional screws are optional Join mounting brackets together with M4 hex head For added safety use additional ceiling grid screws screw and nut Also tighten wingnuts to permanently fix brackets to grid AWARNING Risk of Injury Improper mounting bracket installation may cause injury or property damage Diffuser Installation gt Top Primary diffuser with no film Bottom Anti glare diffuser Primary diffuser with green film faces up remove film before sliding in Option A one diffuser primary Tilt and slide 1B Option B two diffusers primary and anti glare diffusers into base of luminaires The last diffuser Tilt and slide both diffusers into base of luminaires will need
5. r row is fully wiring will not turn on engaged to the malfunctioning luminaire GE Lighting gelighting com GE Lighting is a subsidiary of the General Electric Company Lumination is a trademark of GE Lighting Lighting Solutions LLC The GE brand and logo are trademarks of the General Electric Company 2013 GE Lighting Information provided is subject to change without notice All values are design or typical values when measured under laboratory conditions 01333785 IND076 082313
6. ssory Black to L1 White to N Green yellow to ground Grey to D1 and Violet to D2 for 1 10V or Orange to D1 and Violet to D2 for DALI Note Use BL Series CE Continuous Leader Cable 1 10V SKU 85601 or BL Series CE Continuous Leader Cable DALI SKU 85675 N 3 Connect the accessory kit to the through wiring O Snap in the terminal block to the factory mounted Push wires into fixture holder Be careful not to break the wires at a high angle when pushing them inside the housing Luminaire Installation With the supplied universal bracket the product is compatible with the following USG type grids er Dx DXI DXT DXF DXM Dx ae a yi O Reference diagram right to determine which O o hole to use for a given grid OxTIF O Sye DXI Safety screw holes One is needed gt gt O more are optional Joiner pin S lt 1 For the luminaires that will be in the middle of the Pre install the two M3x12 mm screws with the run insert two pins into one end only Slide pins into wingnuts into bracket The screws should be in the the bottom screw grooves leaving approximately same hole type 20 22mm exposed Must use star washer on top hole Groove Insert four mounting brackets two at each end O Fasten one end cover on the first and last into grooves on both sides of luminaire Position luminaires only with four M3 screws Always use a brackets approximately 2 3m