Home

GarrettCom 6KQ User's Manual

image

Contents

1. Industnal networking products Designed and Manufactured in the USA Overview GARRETTCOM INC OFFERS THE PREMIUM QUALITY MAGNUM LINE OF INDUSTRIAL CONECTIVITY PRODUCTS WITH INDUSTRY STANDARD FUNCTIONALITY AND BUILT IN FIBER CONFIGURABILITY MAGNUM PRODUCTS ARE DESIGNED FOR USE IN DEMANDING INDUSTRIAL GRADE CARRIER CLASS POWER UTILITY AND OEM APPLICATIONS WHERE RELIABILITY IS A PRIMARY CONSIDERATION 6K SERIES MANAGED FIELD SWITCHES GIGABIT 100 AND 10 MBPS FIBER AND COPPER PORTS MIX AND MATCH FEATURES SFF FIBER AND DC POWER IN 1U UNITS DX SERIES SERIAL DEVICE ROUTERS ETHERNET AND SERIAL 4K SERIES SWITCHES 100 AND 10 MBPS COPPER PORTS WITH OPTIONAL FIBER PORT WITH AUTO NEGOTIATING FULL SWITCHING PERFORMANCE QUAD SERIES FIBER SWITCHES 100 amp 1OMBPS FIBER AND COPPER PORTS MIXED SPEED AND MIXED MEDIA TYPES FULL SWITCHING PERFORMANCE MP62 AND P62F OUTDOOR ETHERNET SWITCHES FOR TEMPERATURE UNCONTROLLED LOCATIONS 6 10 100 AND 2 100MB FIBER PORTS CAN BE CONNECTED IN STRINGS MIXED MEDIA FIBER HUB 16 PORT 10 100 AUTO SENSING DUAL SPEED 8 PORT AND 16 PORT 10 100 AUTO SENSING HUBS PERSONAL SWITCHES 10 100MB 8 PORT DUAL SPEED AUTO NEGOTIABLE WITH FIBER OPTION PERSONAL HUBS 100MB OR 10 100MB 8 PORT WITH 2 SWITCHED PORTS 1 FIBER BUILT IN PERSONAL HUBS 10MB SERIES 8 PORT AUI STACKABLE TO 5 HIGH OPTIONAL BNC OF FIBER PORT 8 OR 9 PORT AND 4 OR 5 PORT PERSONAL HUBS W MAN UP LINK SW MEDIA CONVER
2. for 9 125 Single mode is 0 4 dB km LXSC25 and the Cable Loss for 9 125 Single mode is 0 25 dB km LXSC40 and the Cable Loss for 9 125 Single mode is 0 2 dB km LXSC70 The following data has been collected from component manufacturer s Agilent s and Lucent s web sites and catalogs to provide guidance to network designers and installers Fiber Std Wave Port Size Module Std fdx length nm 6KP4V 10Mb Multi 850 62 5 125 F10ST Mode 6KPV 100Mb Multi 1309 62 5 125 MST MSC FX mode oa 50 125 ea Single 6KPV SSC 1300 9 125 wimi Single 40 6KPV FX mode 0 4 1300 9 125 SSCL 6Kpy 100Mb Multi 2 1300 62 5 125 _ 2 6KPV 100Mb Multi 4 1300 62 5 125 MLC FX mode 6KPV SLC 100Mb Single 1310 9 125 Mode Magnum D Mb Single SFP LX10 FX 1310 9 125 Gigabit Magnum 1000 Mb Single SFP LX25 FX 1310 9 125 Gigabit Magnum 1000 Mb Single 40 SFP LX40 1550 9 125 Magnum Single 70 SFP LX70 1550 9 125 Note The use of either multi mode or single mode fiber to operate at 100Mbps speed over long distances i e in excess of approx 400 meters can be achieved only if the following factors are both applied 34 Magnum 6KQ Managed Field Switch Installation and User Guide 04 07 5 0 5 1 5 2 e The 100Mb fiber segment must operate in full duplex FDX mode i e the full duplex factory default setting for 1OOMbps fiber ports must
3. of operating conditions on that port Using the 6KQ MNS 6K management software the user may disable auto negotiation and fix the desired operation of each RJ 45 port The user may select 10Mb or 1OOMb speed and full or half duplex mode per port as per user requirements See Magnum MNS 6K Software Manual for details info 2 2 3 PoE power pass through model P6KQ4 RJ45 MDIX 10 100Mb 4 port The PoE Power over Ethernet RJ 45 ports are similar to regular RJ 45 ports except they have the capability of providing power on each port to power up the PD devices per the IEEE802 3af PoE standard The power pass through PoE modules are _ www GarrettCom com a 10 Magnum 6KQ Managed Field Switch Installation and User Guide 04 07 dependent upon the 48VDC input power to supply the PD power for these RJ 45 10 100 ports Each port supplies up to 15watts to power the PoE PD devices A maximum of 8 PoE ports can be configured in the A and B slots of a 6KQ switch with 48vdc power input The PoE modules are also available with mix n match fiber modules configured in other 6KQ slots Please check the Configuration Guide and the ordering information Sec 1 2 for all the various P6K PoE module options The LEDs on P6KQ4 RJ45 4 Port 10 100Mb PoE Copper ports Qa ACT 2 10 100 PoE 4 FULL HALF P6KQ4 RJ45 PoE modules are slightly different compared to regular non PoE RJ 45 modules as shown in Fig 2 When the PoE port is in use
4. the POE LED is ON when connected properly to an 803 af compliant PD device on that port When non PoE devices are connected the POE LED is OFF The operation of Ethernet data traffic is not affected by PoE LINK and ACTIVITY LEDS are combined on the PoE modules into one LED that is marked as LINK ACT as shown in the diagram 2 2 4 Two Port Fiber Modules 2 100Mb fiber The two port modules are available as two 100Mb fiber ports ST or SC connector styles are available utilizing multi mode or single mode fiber optics These fiber modules may be factory configured with a choice of them in slot B and D only The fiber port s LEDs indicate status the same as the SFF fiber modules in Section 2 2 2 above Color coding on the panel of the module shows which LEDs belong to which port LEE TX BLK RX TX K RX 2 100 Mb SC 2 100 Mb ST 1 Magnum 6KQ Managed Field Switch Installation and User Guide 04 07 225 Two Port 10 Mb mm Fiber ST Modules The 2 port 10Mb ST fiber modules behave the same as the 2 100Mb ST fiber modules except for the 1OMb speed The default setup on the 1OMb fiber module is half duplex which allows the Magnum 6KQ Switch to connect to any 10Mb hub or media converter or almost any other device with a 1OMb fiber Ethernet port The default setting of the 1OOMb fiber module is full duplex User mode control per port through the MNS port settings software is the same as the other 6KQ modules The fib
5. Form C Normally Closed NC contact is held close during normal software operation A user defined software malfunction such as an SNMP Trap or a Software Security violation or an S Ring Fault causes the contact to open and thus triggers an alarm in the user s monitoring system The second NC Alarm Contact is held closed when there is power on the main board inside of the Switch This provides a Hardware Alarm because the NC contacts will open when internal power is lost either from an external power down condition or by the failure of the power supply inside of the Magnum Switch Useful info about Alarm contacts 1 There are four terminal blocks 1 2 3 4 provided next to the DC power supply 2 The top two pins 1 2 are software operated 3 The bottom two pins 3 4 are hardware operated 4 These are both NC normally closed relays a N M Relay Contacts 5 The switch s software operation needs to be enabled and set to get the Alarm traps For detailed information about the Software Alarm and software control of SNMP alarm traps please reference the Magnum MNS 6K Software User Manual Chapter 19 _ www GarrettCom com 28 Magnum 6KQ Managed Field Switch Installation and User Guide 04 07 The Alarm Contacts are on the front left area next to the DC power source of the Magnum 6KQ unit and are green in color as shown in the picture 3 6 6KQ Port Module 6KPM Installation Magnum 6KQ Switches are
6. Magnum 6KQ Managed Field Switch Installation and User Guide 04 07 other communication companies In addition many high availability equipment services such as broadcasters publishers newspaper operations brokerage firms and other facilities often use a battery backup system to maintain operations in the event of a power failure It is also frequently used for computer system backup management and operations monitoring equipment The 24V and 125VDC options are particularly useful in the industrial environment where it is common for facilities to operate on 24VDC or 125VDC power The 125VDC options are mainly used in power utilities such as electrical substations electrical generating plants etc The 24VDC applications are mainly in heavy duty industrial automation such as factory floor process plants HVAC military equipment etc B4 0 6KQ 48V 24 125VDC INSTALLATION This section describes the proper connection of the 48VDC leads or 24VDC 125VDC leads to the DC power terminal block on the Magnum 6KQ Switch The DC terminal block on the Magnum 6KQ Managed Switch is located on the left front of the unit and is equipped with four 4 screw down lead posts The power terminals are identified as positive and negative and they are electrically floating inside the unit so that either may be grounded by the user if desired The chassis is earth or ground GND The connection procedure is straightforward Simply insert t
7. Small FF A LINK 2 10 100 The Magnum 6KQ4 RJMT Module is a combo module with copper ANAT Q FULL HALF and fiber Small Form Factor MTRJ type ports The small size of MTRJ connectors provides an advantage of placing more ports on one module The 6KQ4 RJMT is equipped with Two 10 100 RJ 45 ports and Two MTRJ fiber ports When installed in a Magnum 6KQ Switch it supports the standard distances as per the media Each port has an Activity ACT LED indicating packets being received a Link LK LED that indicates proper connectivity with the remote device when lit and a FDX HDX LED to indicate full duplex mode when lit or half duplex when off The 10 100 LED indicates 100Mbps speed when lit and at 10Mbps speed when off 5 2 7 6KQ4 MLC 4 ports 100Mbps multi mode LC connector SFF Magnum 6KP8 MLC is a Four port multi mode fiber LC connector small form factor used primarily in 100Mbps fiber to the desktop links When installed in a Magnum 6KQ Switch it 6KQ4 LC 4 100 Mb LC Fiber Port supports fiber optic OK O LK E LK cable distances up to the IEEE standard 100Mbps distance limits 1 e typically 2km at full O LINK 2 Activity duplex and 412m at half duplex 3 rg The compact size of the LC Connector reduces the size of wiring panels in wiring closets while providing the advantage of future proof fiber optic technology _ ww GarrettCom com 39 Magnum 6KQ Managed Field Switch In
8. Switch Installation and User Guide 04 07 1 2 Ordering Information Magnum Managed Field Switch 16 ports max MODEL DESCRIPTION Magnum 6KQ 24VDC Magnum 6KQ Managed Field Switch base unit with 24VDC power supply and four 10 100 copper ports May be configured with a selection of 10 100 1000 fiber and copper port connector types from a family of 6KQ port modules per the 6KQ configuration guide 16 total ports max Heavy duty and environmentally hardened no fans Dual LEDs for all around status viewing Wire speed filtering and forwarding across all ports 802 3x flow control 802 1p priority packet processing self learning 4K node address table large 240KB packet buffers for 10 100 and 120KB for 1000Mb For licensed managed networks software MNS 6K RS Ring and S Ring including GUIs for ease of use and industry leading security features see separate data sheets Magnum 6KQ 48VDC Same as 6KQ 24VDC except the power input is 48 VDC Magnum 6KQP 48VDC Same as 6KQ 48VDC except the four 10 100 RJ 45 are PoE Magnum 6KQ 125VDC Same as 6KQ 24VDC except the power input is 125VDC PSAC 24V60 External Hardened Power Supply for AC to 24VDC 60 watts panel or DIN RAIL mount PSAC 48V150 External Hardened Power Supply for AC to 48VDC for PoE 150 watts panel or DIN RAIL mount Please use this URL for the complete Configuration Guide for the Magnum 6KQ http www garrettcom com techsupport insertion_guides 6kqcg pdf Configuration O
9. and TACACs Telnet TFTP FTP support Spanning Tree Protocol Link Loss Learn S Ring with license key multi level QoS Port and tag based VLANs GVRP IGMP Snooping SNMPc GUI support Event Log SNTP client for time of day BootP and DHCP client for IP configuring and password security and Secured Web interface 15 Magnum 6KQ Managed Field Switch Installation and User Guide 04 07 2 4 Applications Magnum 6KQ Field Switches offer high performance modularity and availability They provide the flexibility of 1OOMbps fiber and copper ports as well as single or dual Gigabit LOOOMb ports with industry standard LAN management software Magnum 6KQ Switches are easily used in a variety of applications including client server computing secure VLAN performance upgrades to departmental networks and stream traffic for VOIP and audio video applications They can also be used in a very diversified combination of mixed media in Industrial floor applications The performance characteristics of the 6KQ Switches enable them to inter connect a series of subnets one subnet per 6KQ Switch port in a LAN traffic center The subnet connections may be via fiber or twisted pair cabling 100Mbps or 10 Mbps speed and full or half duplex The mixed media modular capability is ideal for industrial applications where existing Ethernet LAN network cabling must be accommodated The fiber built in media capability is ideal for integrating future proof fiber
10. are set for auto negotiation and are connected to another auto negotiating device there are 4 different speed and F H modes possible depending on what the other device supports These are 1 100Mb full duplex 2 100Mb half duplex 3 10 Mb full duplex and 4 10 Mb half duplex The auto negotiation logic will attempt to operate in descending order and will normally arrive at the highest order mode that both devices can support at that time Since auto negotiation is potentially an externally controlled process the original highest order mode result can change at any time depending on network changes that may occur If the device at the other end is not an auto negotiating device the 6KQ s RJ 45 ports will try to detect its idle signal to determine 10 or 100 speed and will default to half duplex at that speed per the IEEE standard General information Auto negotiation per port for 802 3u compliant switches occurs when the devices at both ends of the cable are capable of operation at either 10Mb or 100Mb speed and or in full or half duplex mode and can send receive auto negotiation pulses and the second of the two connected devices is powered up i e when LINK is established for a port or the LINK is re established on a port after being lost temporarily 32 Magnum 6KQ Managed Field Switch Installation and User Guide 04 07 e NOTE Some NIC cards only auto negotiate when the computer system th
11. be used and e The worst case OPB of the fiber link must be greater than the fiber cable s passive Attenuation Attenuation Cable loss LED aging loss Insertion loss safety factor Introduction Magnum 6KQ Managed Field Switch Port Modules This chapter describes each Port Module PM including appearance functionality and status displays Inspecting the Package and Product This section applies only to PMs shipped as separate items 1 e 6kQ PMs not factory installed in a Magnum 6KQ PM slot Examine the shipping container for obvious damage prior to installing a 6KQ PM notify the carrier of any damage you believe occurred during shipment or delivery Inspect the contents of this package for any signs of damage and ensure that the items listed below are included This package should contain 1 or more 6KQ units or 6KQ PMs Installation instructions with illustrations Remove the 6KQ PM s from the shipping container Be sure to keep the shipping container should you need to ship any of the PMs separately at a later date In the event there are items missing or damaged contact your supplier If you need to return the unit use the original shipping container if possible Refer to Chapter 5 for specific return procedures 6KPM Module Description An important feature of the Magnum 6KQ is the use of Port Modules for flexible mixed media connectivity to RJ 45 and fiber media Since the Magnum 6KQ Switches have dual speed
12. of ground potential rise GPR during line to ground fault conditions The 6KO passes the 161 3specifications for zero packet loss with fiber ports amp with RJ45 ports used as indicated here 5 2 10 PoE power pass through Base unit Model 6KQP 48VDC 10 100Mb 4 port See Section 2 2 3 for basic PoE ports information The LEDs on PoE ports are slightly different compared to regular non PoE RJ 45 modules When the PoE port is in use the POE LED is ON when connected properly to a 803 af compliant PD device on that port When non PoE devices are connected the PoE LED is OFF Operation of Ethernet data traffic is not affected by PoE LINK and ACTIVITY LEDS are combined on the PoE modules into one LED that is marked as LINK ACT PoE LEDs Summary e For PoE devices each RJ 45 PoE port supports only 802 3af complaint devices The PoE LED is ON when the attached PD is drawing power from the port e For non PoE devices connected the PoE port will act as a normal RJ 45 port and the PoE LED is OFF No power is being sent out from the port e The PoE ports in Magnum 6K s with 48VDC power input act as a pass through so the 48VDC power source must be strong enough to provide power to the 6K switch and to all the 4 RJ 45 ports with PD devices connected up to 15 watts per PoE port e In the case where the 48 VDC power in not internally connected and no power is coming to the PoE ports for some reason all the PoE port LEDs are ON simultaneous
13. that port when lit The copper Gigabit ports come with speeds indicating 10 100 1000Mb LEDs also The operation of the Gigabit SFP and 10 100 1000 RJ 45 ports is as described for those port types above For detailed information about 10Mb mm ST fiber half of the module see Section 2 2 5 2 2 7 Packet Prioritization 802 1p QOS Quality of Service means providing consistent predictable data delivery to users from datagram paths that go all across a network As a LAN device the Magnum 6KQ can do its part to prevent any QOS degradation while it is handling Ethernet traffic through its ports and buffers The Magnum 6KQ switching hardware supports the IEEE 802 1p standard and fulfills its role in support of QOS giving packet processing priority to priority tagged packets according to the 802 1p standard In addition to hardware support for QOS the MNS software R2 supports two priority queues that can be shared across the eight levels of defined packet priorities for application specific priority control by the user through software configuration settings 2 2 8 Frame Buffering and Flow Control Magnum 6KQ s are store and forward switches Each frame or packet is loaded into the Switch s memory and inspected before forwarding can occur This technique ensures that all forwarded frames are of a valid length and have the correct CRC 1 e are good packets This eliminates the propagation of bad packets enabling all of the available ban
14. you believe occurred during shipment or delivery Inspect the contents of this package for any signs of damage and ensure that the items listed below are included This package should contain 1 Magnum 6KQ Managed Field Switch base unit configured with user selected port module options installed 1 Set of two metal vertical mounting brackets with screws to the case 1 Installation and User Guide this manual 1 Product Registration Card Remove the items from the shipping container Be sure to keep the shipping container should you need to re ship the unit at a later date To validate the product warranty please complete and return the enclosed Product Registration Card to GarrettCom Inc as soon as possible In the event there are items missing or damaged contact the party from whom you purchased the product If the unit needs to be returned please use the original shipping container if possible Refer to Section 6 Troubleshooting for specific return procedures Magnum 6KQ Managed Field Switch Installation and User Guide 04 07 2 2 Product Description Magnum 6KQ Field Switch Magnum 6KQ Managed Field Switches provide maximum configurability in their class The fiber rich 6KQ can be configured with up to 12 1OOMb fiber ports and two Gigabit ports For 10 100 copper regular or PoE equipped 10 100 RJ 45 or 10 100 1000 copper ports may be configured to a maximum or 12 at 10 100 and 2 Gig ports Magnum 6KQ comes with the best of b
15. 2 Wipe clean the ends of the dual connectors with a soft cloth or lint free lens tissue dampened in alcohol Make certain the connectors are clean before connecting Note One strand of the duplex fiber optic cable is coded using color bands at regular intervals you must use the color coded strand on the associated ports at each end of the _ www GarrettCom com 24 Magnum 6KQ Managed Field Switch Installation and User Guide 04 07 fiber optic segment 3 Find the Transmit TX and Receive RX markings on the SFP transceiver to verify the top side of it Some of the transceiver marks arrow sign for up 4 Position the SFP transceiver correctly before insertion and then insert the SFP transceiver carefully until the transceiver connector snap into the place in the socket connector 5 Connect the Transmit TX port on the Magnum PM to the Receive RX port of the remote device Connect the Receive RX port on the PM to the Transmit TX port of the remote device The LINK LED on the front of the PM will illuminate and turn Green when a proper connection has been established at both ends and when power is ON in the unit If LINK is not lit or OFF after cable connection the normal cause is improper cable polarity Swap the fiber cables at the PM connector and also check the connectivity on the target device to remedy this situation Reconfigure or reboot both the device if required If connected properly you c
16. 5 screw down lead posts The block primary terminals are identified as positive A Figure C5 0 DC Dual Source wiring connections to the External Terminal Block on a Magnum 48VDC with Dual Source option negative A and the secondary power terminals as negative B positive B The chassis is earth The Dual Source terminal block for the 24 48 and 125VDC are same Note The GND should be hooked up first The 6KQ unit has a floating ground so the user may elect to Ground either or terminal to suit the customer s use Before connecting hot lines to the Terminal Block of 48VDC 24VDC or 125VDC always use a digital voltmeter to measure the output voltage of the power supply and determine the lead which is more _ www GarrettCom com 49 Magnum 6KQ Managed Field Switch Installation and User Guide 04 07 ve potential The more ve voltage lead from 48V or 48V supply must be connected to the post labeled The connection procedure is straightforward Simply connect the DC leads to the Switch s power terminals positive and negative screws The use of Ground GND is optional it connects to the Switch chassis Ensure that each lead is securely tightened C5 1 UL Requirements The following must be adhered to in order to conform to UL requirements Minimum 18 AWG cable for connection to a Centralized DC power source Minimum 14 AWG cable for connection to earthing wirin
17. 5 with a Four port RJ 45 connector and offers 10 100 full half 4 Ports 10 100Mbps RJ 45 duplex auto negotiating capability on each port The RJ 45 connector is shielded to minimize emissions and will allow both unshielded twisted pair UTP and shielded twisted ir STP cabl nections pair STP cable connections TNE fous 3 Each port has an Activity ACT LED indicating 3 activity 4 FULL HALF packets being received a Link LK LED that indicates proper connectivity with the remote device when lit a FDX HDX LED to indicate full duplex mode when lit or half duplex when off and a 40 Magnum 6KQ Managed Field Switch Installation and User Guide 04 07 10 100 LED indicating 100Mb when lit or 10 Mbps when off Note The 10 100 RJ 45 ports are supported with Auto negotiation and Auto crossover MDIX which allow the RJ 45 ports to automatically Link with any RJ 45 device and eliminate the use of cross over cable NOTE for Power Substations In support of the IEEE 1613 Class 2 standard GCI advises that for substation applications the RJ 45 ports are intended for connectivity to other communication equipment such as routers or telecommunication multiplexers installed in close proximity i e less than 2 meters or 6 5ft to the 6KQ It is not recommended to use these ports in substation applications to interface to field devices across distances which could produce kigh greater than 2500V levels
18. 7 consumption will range from about 20 up to 35 watts depending on the port quantity and types in the configuration When connecting the Ethernet cabling there is no need to power down the unit Individual cable segments can be connected or disconnected without concern for power related problems or damage to the unit Power input options are available to suit the 6KQ Switches to special high availability communications and or heavy industrial grade applications including 48VDC 24VDC and 125VDC with single DC input 48VDC 24VDC and 125VDC with dual source DC input External AC power supplies are optional see Section 1 2 Ordering Information See the Appendices of this manual for more details Use an RFQ for other variations 3 5 Alarm Contacts for monitoring internal power and Software Traps The Alarm Contacts feature standard on Magnum 6KQ s provides two Form C Normally Closed NC contacts to which the user can attach two sets of status monitoring wires at the green terminal block When this option is present the terminal block for Alarm Contacts is part of the Power Input panel in the 6KQ case The DC power input connection is in the same panel The first NC Alarm Contact top position switch vertically mounted is a Software Alarm operated by user settings in the MNS 6K software The user can disable the Software Alarm feature with a software configuration command if desired When the Software Alarm is enabled the
19. LED to indicate full duplex mode when lit half duplex when off 5 2 la 6KQ2 10ST 2 10Mb multi mode FX ST twist lock Module The 6KP6 RJ10ST is a 6KQF 2MSC 2 100 Mb SC Fiber two port Fiber module that looks similar to the 1OOMbFiber module with the exception of 10Mb speed at the ST fiber module The ST connector functions as a fiber optic 2 Activity transceiver to support LOBASE FX network segments When installed 3 in a Magnum 6KQ Managed Switch the fiber port supports fiber optic cable distances up 36 Magnum 6KQ Managed Field Switch Installation and User Guide 04 07 the IEEE standard 10Mbps distance limits 1 e typically 2km at full duplex and half duplex Each port has an Activity ACT LED indicating packets being received a Link LK LED that indicates proper connectivity with the remote device when lit and an FDX HDX LED to indicate full duplex mode when lit or half duplex when off 5 2 2 6KQF 2MSC 2 100Mb multi mode FX SC snap in Fiber connector The Magnum 6KQF 2MSC is two port module equipped with 2 multi mode 100Mbps fiber optic transceivers This is similar to the 6KQF 2MST It has the same LEDs indicating port activity ACT Link LK and FDX HDX and 10 100 operation as well as the same face plate lettering The difference is that the 6 QF 2MSC is equipped with SC type snap in fiber port connector instead of an ST type 5 2 3 6KQF 2SSCL 2 Ports 100Mbps single m
20. OBASE FX SFP modules Fiber Single mode connector types Fiber Port SC type Fiber optic single mode OOBASE FX Fiber Port LC type Fiber SFF single mode 1 OOBASE FX Fiber Port 1OOOBASE FX SFP modules LEDs Per Port one set at the port one set on swivel top on right side LK Steady ON when media link is operational ACT ON with receiver port activity FDX HDX ON Full Duplex Mode OFF Half Duplex Mode 100 10 ON 100Mbps speed OFF 10 Mbps Operating Environment Ambient Temperature 40 to 140 F 40 to 60 C for UL60950 and Component Parts rating 60 to 195 F 50 to 85 C for IEC 60068 Type Test short term rating Storage Temperature 60 to 210 F 50 to 100 C Ambient Relative Humidity 5 to 95 non condensing Altitude 200 to 13 000 ft 60 to 4000m Conformal Coating humidity protection option Request quote Alarm Relay Contacts One NC indicating internal power one NC software controllable Packaging Enclosure High strength extruded aluminum Dimensions 6 85 in H x 7 5 in W x 2 0 in D 17 4 cm H x 19 1 cm W x 5 08 cm D Cooling method Convection fully enclosed ribbed surface aluminum case used as a sink designed for vertical mounting no fans Weight 3 Ibs 1 3 kg Management Console connector Serial RJ 45 see details at sec 3 7 DC Power Supply Internal floating ground design 24VDC Power Input nominal 18 to 36VDC range 48VDC Power Input nominal 36 to 60 VDC range 125VDC P
21. OOMb SX 1310nm wavelength 10Km SFP LX25 Giga SFP transceiver 1 OOOMb SX 1310nm wavelength 25Km SFP ZX40 Giga SFP transceiver 1 OOOMb SX 1550nm wavelength 40Km SFP ZX70 Giga SFP transceiver 1 OOOMb SX 1550nm wavelength 70Km MNS 6K License _MNS 6K managed software is pre loaded from the factory S RING Key S Ring and RS Ring Redundancy Manager licensed software for redundant ring management One S Ring or RS Ring key is for licensed use one 6K managed self healing Ring CONSOLE CBLQD Serial RJ45 cable DB9 RS 232 null modem female connector on one side and RJ 45 on the other side for the RJ 45 Management port Console port CONSOLE CBLQU USB RJ45 cable USB connector on one side and RJ 45 to the other side for the RJ 45 Management port Console port DIN RAIL 6KQ Din Rail holder for a secure vertical mount with screws for 6KQ KQ CABLE BKT Metal bracket for 6KQ used for cable strain relief for vertical mount CONFORMO05 CRM conformal coating heavy duty silicone at 5 mil thickness for interior PCBs PS and modules GarrettCom Inc reserves the right to change specifications performance characteristics and or model offerings without notice _ www GarrettCom com 5 Magnum 6KQ Managed Field Switch Installation and User Guide 04 07 2 0 Introduction 2 1 Inspecting the Package and Product Examine the shipping container for obvious damage prior to installing this product notify the carrier of any damage that
22. TERS 10MB AND 100MB SERIES ALL MEDIA COMBINATIONS INCL FIBER ST SC MM SINGLE MODE THE X LINE OF CONFIGURABLE MIXED MEDIA PRODUCTS STACKABLE CONCENTRATORS SNMP OPTIONAL 13 PORTS MINI CONCENTRATORS 7 PORTS REPEATERS 2 PORTS REPEATER PORT MODULES RPMS 6 TYPES FOR ETHERNET MEDIA COAX TRANSCEIVERS 10MB SERIES Magnum 6KQ Managed Field Switch Installation and User Guide 04 07 1 0 SPECIFICATIONS 1 1 Technical Specifications Performance Filtering Forwarding Rate Ethernet 1OMb 14 880 pps Fast Ethernet 1OOMb 148 800 pps Gigabit Ethernet LOOOMb 1 488 000 pps Switching Processing Type Store and Forward with IEEE 802 3x full duplex flow control non blocking Data Rate 1OMbps l100Mbps and 1000Mbps Address Table Capacity 4K node self learning with address aging Packet buffer size 240KB for 10 100 and 120KB for 1000Mb Latency 5 us packet time 100 to 1OOMbps 15 us packet time 10 to 10 Mbps and 10 to 1OOMbps Throughput with 12 10 100 and 2Glink max 4 76M pps Transmit Back plane 2 66Gb s per slot Network Standards and Compliance hardware Ethernet V1 0 V2 0 IEEE 802 3 1OBASE T IEEE 802 3u 100Base TX 10OBASE FX IEEE 802 3z 1000BASE X Ethernet Auto negotiation IEEE 802 3ab 1OOOBASE X Ethernet IEEE 802 1p Priority protocol IEEE 802 1d Spanning tree protocol IEEE 802 1w Rapid Spanning tree protocol IEEE 802 1g VLAN Tagging IEEE 802 3x Flow Control TEEE 802 3ad Link Aggregation Trunk
23. UME packet to tell the transmitter to start sending the packets Of course the transmitting device must also support the 802 3x flow control standard in order to communicate properly during normal operation Note When in Half Duplex mode the 6KQ Switch implements a back pressure algorithm on 10 100 Mb ports for flow control That is the switch prevents frames from entering the device by forcing a collision indication on the half duplex ports that are receiving This temporary collision delay allows the available buffer space to improve as the switch catches up with the traffic flow 4 5 Power Budget Calculations for 6KQ PM s with Fiber Media Receiver Sensitivity and Transmitter Power are the parameters necessary to compute the power budget To calculate the power budget of different fiber media installations using Magnum products the following equations should be used OPB Optical Power Budget Pr min Pr min where P Transmitter Output Power and Pp Receiver Sensitivity Worst case OPB OPB 1dB for LED aging 1dB for insertion loss _ www GarrettCom com a 33 Magnum 6KQ Managed Field Switch Installation and User Guide 04 07 Worst case distance Worst case OPB in dB Cable Loss in dB Km where the Cable Loss for 62 5 125 and 50 125um M m is 2 8 dB km and the Cable Loss for 100 140 Multi mode is 3 3 dB km and the Cable Loss for 9 125 Single mode is 0 5 dB km and the Cable Loss
24. a E iE EA EE ska Factory 3 ii Floor PLC fz a al a A Z A j Magnum A B A H CKO Factory Factory EA Floor PLC Floor PLC EE SS E Factory Floor PLC Fig 2 4a The industrial factory floor application with Magnum 6KQ Example 2 A managed network is needed to provide a redundant ring topology for maximum redundancy In a network where any faulty cable cable disconnection or 17 Magnum 6KQ Managed Field Switch Installation and User Guide 04 07 power failure can bring the whole thing down a ring switch can be reconfigured and up and running in milliseconds The ring topology of the network consists of high speed LAN segments supported by 100Mbps full duplex future proof fiber media to provide a secure long distance LAN connection The entire network is sharing a higher bandwidth Gigabit enabled data mining server for the vital database located in a separate secured building The copper ports are required for multiple subnets inside the power plant to check the status of other Ethernet units The entire spread network will be manageable to provide easy detectable uninterrupted support through a viewable SNMP monitor The Magnum 6KQ Managed Field Switch equipped with a mix of copper and fiber ports provides an economical and seamless solution to many requirements The user configurable Magnum 6KQ provides an extra boost to the network requirements by providing copper fiber media along with the higher ba
25. a provide widespread options to the users to mix and match their legacy and advance network needs The modularity of the 6KQ Managed Field Switches make them an attractive choice for use in applications with LAN connections to an organization s multiple site offices and factory floors The different locations can be easily connected together with the Fiber ports supported by the Magnum 6KQ Switch A main NT server in a secure area protected from earthquake or fire hazards can be connected to the full duplex Gigabit Fiber port Extended temperature ratings and a variety of options for AC DC power supplies qualify this managed 6KQ switch for use in non temperature controlled networks and many other temperature sensitive critical Industrial applications where above normal room temperatures occur while the network is in operation Full duplex future proof fiber media can easily connect long distance subnets and provide a stable secure network to all applications The SNMP management capability of the Magnum 6KQ Switch helps create a database of all the network subnets to easily manage the network Hi Magnum 6K25 a Eo O SNMP deel eL Em E Monitor i A F Main SERVER IBER Connection m 5 i i FIBER Connction a ED Internet 11 E 3 Router Oo lE Magnum GKE FIBER Conngetion l S ER FIBEQ Connection FIBER Connection to a other BLDG H a a m mS EA TAR o Magnum R A I E 6KQ E LE Maghum
26. an check via MNS 6K software too for verification the validity of SFP Gigabit ports Make sure Rel 3 6 or higher firmware is loaded on the 6KQ switches to support the SFP transceivers 3 3 DIN Rail Mounting the Magnum 6KQ The Magnum 6KQ is designed for use in a factory floor industrial environment It is available with optional DIN Rail brackets to mount it securely in a metal factory floor enclosure maintained vertically for proper convection cooling of the unit The Magnum 6KQ requires one DIN Rail mounting clip or latch for secure mounting These may be ordered as Model DIN RAIL 6KQ See a 6KQ viewed from the side at the left with model DIN RAIL 6KQ in place on the unit _ www GarrettCom com a 25 Magnum 6KQ Managed Field Switch Installation and User Guide 04 07 The Din Rail Latching clips are mounted on the upper side corners of the 6KQ unit Two threaded holes are provided on the sides of 6KQ for DIN Rail mounting purposes See side view at the left The required two screws are included with the DIN Rail brackets and are no 10 32 X 3 8 PHIL PAN w star washer The two heavy duty Din Rail latches are designed as if that they can be manually accessed from the top when the 6KQ is installed on a DIN Rail To install the 6KQ with the DIN Rail brackets and latches attached to it hold the 6KQ in the side vertical position with the bottom out and with the top moved in toward the DIN Rail Position the latches over the
27. at they are in is powered These are exceptions to the negotiate at LINK enabled rule above but may be occasionally encountered When operating in 1OOMb half duplex mode cable distances and hop counts may be limited within that collision domain The Path Delay Value PDV bit times must account for all devices and cable lengths within that domain For Magnum 6KQ Fast Ethernet switched ports operating at 100Mb half duplex the bit time delay is 5OBT 4 4 Flow control IEEE 802 3x standard Magnum 6KQ Switches incorporate a flow control mechanism for Full Duplex mode The purpose of flow control is to reduce the risk of data loss if a long burst of activity causes the switch to save frames until its buffer memory is full This is most likely to occur when data is moving from a 1OOMb port to a 10 Mb port and the 10Mb port is unable to keep up It can also occur when multiple 100Mb ports are attempting to transmit to one 100Mb port and in other protracted heavy traffic situations Magnum 6KQ Switches implement the 802 3x flow control non blocking on Full Duplex ports which provides for a PAUSE packet to be transmitted to the sender when the packet buffer is nearly filled and there is danger of lost packets The transmitting device is commanded to stop transmitting into the 6KQ Switch port for sufficient time to let the Switch reduce the buffer space used When the available free buffer queue increases the Switch will send a RES
28. cabling into the LAN structure Example 1 Magnum 6KQ Switch for a Industrial Application Equipped with lots of useful features including hardened enclosures a wide spread of DC power supply options and extended temperature ratings qualifies the Magnum 6KQ Managed switch for any Industrial factory floor traffic control transportation system or power utility application The several MNS 6K software operated features qualifies this managed switch to operate and perform securely and reliably in all critical applications The addition of S Ring and the Link Loss Learn software features allow this Managed switch to provide a very secure highly available redundant network capability in any ring topology network The Managed 6KQ s modularity along with the MNS 6K management software features remarkably handle industrial environments i e where the factory floors are networked with Ethernet based mixed media LANs equipped with PLCs computers for taking readings and data from Machines Client Server databases etc and sending these important data to the central office data warehouses very securely and reliably The DIN Rail Mounting options on the Magnum 6KQ allow the factory floor s industrial user to mount the 6KQ securely anywhere on their Network setup The option of setting the ports at 10 or 1OOMb on copper and 10 or 100Mb on _ www GarrettCom com 16 Magnum 6KQ Managed Field Switch Installation and User Guide 04 07 fiber medi
29. capability for copper ports the 1 2 3 or 4 port interfaces are designed to support all standard Ethernet media types at 10 or 100 or 1000Mps speed Each 6KQ PM provides a wide selection of connecting Ethernet media segments with all similar or combo connector types 35 Magnum 6KQ Managed Field Switch Installation and User Guide 04 07 Note The 6KQ Port modules are not identical to the port modules used in other 6K products such as the 6K25e and 6K16V For information about other 6K roducts please see the applicable manual For a list of 6KO Port Modules refer to Section 1 2 Each 6KQ Port Module PM is individually described in the following sections 5 2 1 6KQF 2MST 2 100Mb multi mode FX ST twist lock Combo Module The Magnum 6KQ 2MST is two port ST fiber module at 100MB The module is equipped with dual mode ST type connectors and dual speed copper ports The ST connector functions as a fiber optic transceiver to support OOBASE FX network segments When installed in a Magnum 6KQ Managed Switch the copper port supports the standard distance 100m on each port and the fiber port supports fiber optic cable distances up the IEEE 6KQF 2 100 Mb ST Fiber standard 100Mbps distance limits 1 e typically 2km at G full duplex and 412m at half duplex Each port has an Activity ACT LED indicating packets being received A Link LK LED indicates proper connectivity with the remote device when lit and FDX HDX
30. cell tower 8 8 68 AA applications are present Magnum 6KQ Field Switches are provided with LAN management software including SNMP Tag and Port based VLANs IGMP L2 and IGMP Snooping and Port Security with control via GUI and command line interface CLI For high availability LANs using ring topologies Spanning Tree Protocol RSTP Link Loss Learn and S Ring are available Dual Homing is a software configuration feature See the Managed Networks Software MNS 6K and S Ring datasheets for additional details on the comprehensive set of software programs and options Magnum 6KQ Managed Field Switches have heavy duty aluminum cases and are readily available with standard Industrial grade 24VDC power Alternative internal DC power options are available DC power input types may be 24V 48V 125V and dual source DC input is optional on all 6KQ s AC power is available via an external power supply unit see Section 3 4 for details _ www GarrettCom com a 8 Magnum 6KQ Managed Field Switch Installation and User Guide 04 07 Alarm Relay contacts provided on each Magnum 6KQ Switch monitor the hardware and software through traps providing a record of any losses of power signals and other user defined software events See Section 3 5 for details The wide selections of Quad port queen size modules are key to the flexibility and adaptability of Magnum 6KQs Some of the popular 4 ports modules are described below For a list o
31. dcsconrvivestncrvcasarveves 37 I2 6KQF 2SSCL FX SC type Sgl M sseeeeseesssssssssssssssssereressssee 37 5 2 4 6KQ3 RJMSC COMBO connector eeeeeeeeeeeeeeseceesrcrssrerses 38 5 2 5 6KQ4 MT MTRJ Small Form factor o o 38 5 2 6 6KQ4 RJMT COMBO multi mode FX MTRJ Small FF 39 5 2 1 6KQ4 MLC LC connector SEP ssesessesensesossesessssossessssesrosssssss 39 5 2 8 6KQ4 RJMLC LC small form factor and oseese 40 5 2 9 6KQ4 RJ45 Twisted Pair 10 100Mb 4 Port 0 ee 40 5 2 10 PoE power pass through Base unit Model 6KQP 48VDC 41 5 2 11 SFPs Gigabit 1000Mbps port modules eeeeeeeeeeeeeees 42 52 12 ORO BUNK sesioen ii 43 6 0 NCC ORO lOO Ce a EE Aa 43 6 1 Before Calling for Assistance ccccccccceccececceeeseeeseeeseeeceeeeeeeeeeeaaas 43 6 2 When Calling for Assistance ccscsseeecccecceeceeeaasseesseeseeeeeeeeess 44 6 3 Return Material Authorization RMA Procedure ccccece eee 44 6 4 Shipping and Packaging Information ccccccccceeceasssseeeeseeeeeeeeees 44 APPENDIX A WARRANTY INFORMATION sccccsssssssssssssssssees 45 APPENDIX B DC Power Input csccsscccscces ctesccesscosccsvccesecesscescsstecsstevenessteceseasys 46 APPENDIX C Internal DC Dual Source Power Input Option 48 Revisions 04 07 Release as Rev A first printing Magnum 6KQ Managed Field Switch Installation and User Guide 04 07 THE MAG NUM LINE
32. dwidth to be used for valid information While other switching technologies such as cut through or express impose minimal frame latency they will also permit bad frames to propagate out to the Ethernet segments connected The cut through technique permits collision fragment frames which are a result of late collisions to be forwarded which add to the network traffic Since there is no way to filter frames with a bad CRC the entire frame must be present in order for CRC to be calculated the result of indiscriminate cut through forwarding is greater traffic congestion especially at peak activity Since collisions and bad packets are more likely when traffic is heavy the result of store and forward operation is that more bandwidth is available for good packets when the traffic _ www GarrettCom com a 13 Magnum 6KQ Managed Field Switch Installation and User Guide 04 07 load is greatest When the Magnum 6KQ Switch detects that its free buffer queue space is low the Switch sends industry standard full duplex only PAUSE packets out to the devices sending it packets to cause flow control This tells the sending devices to temporarily stop sending traffic which allows the traffic to catch up without dropping packets Then normal packet buffering and processing resumes This flow control sequence occurs in a small fraction of a second and is transparent to an observer Another feature implemented in the Magnum 6KQ Switche
33. e remote device Begin with the color coded strand of the cable for this first TX to RX connection 4 Connect the Receive RX port dark colored post on the PM to the Transmit TX port of the remote device Use the non color coded fiber strand for this The LINK LED on the front of the PM will illuminate when a proper connection has been established at both ends and when power is ON in the unit If LINK is not lit after cable connection the normal cause is improper cable polarity Swap the fiber cables at the PM connector to remedy this situation 3 2 2 Connecting Fiber Optic SC type Snap In The following procedure applies to installations using a PM with SC type fiber connectors 1 e using 6Kq MSC 6KQ SSC single mode When connecting fiber media to SC connectors simply snap on the two square male connectors into the SC female jacks of the 6K PM until it clicks and secures 3 2 3 Connecting Single Mode Fiber Optic When using single mode fiber cable be sure to use single mode fiber port connectors Single mode fiber cable has a smaller diameter than multi mode fiber cable 9 125 microns for single mode 50 125 or 62 5 125 microns for multi mode where xx xx are the diameters of the core and the core plus the cladding respectively Single mode fiber allows full bandwidth at longer distances and may be used to connect 10 Mb nodes up to 10 Km apart or 18Km with the 6K SSC The same procedures as for multi mode fiber applies to s
34. e two inputs C4 0 FEATURES AND BENEFITS OF THE DUAL SOURCE DESIGN a The Switch unit can receive power from either input A or B The hub will normally draw its power from the DC source with the highest voltage at a given time b The Switch unit will not allow power to flow from a higher voltage input to a lower voltage input 1 e the two DC power sources are not mixed together by the hub c When one correct DC input is present the Switch will receive power if the other DC input is absent or even if it is connected with reverse polarity or shorted or grounded d Reverse polarity connections if they should accidentally occur on either input will not damage the Switch or power supply internally nor will it blow the fuse in the internal power supply because of the blocking action of the diodes This is true even if one input connection is reversed while the Switch is operating from the other source e The Switch will not receive power and will not work when both inputs are simultaneously absent or are both incorrectly connected C5 0 INSTALLATION This section describes the proper connection of the 48VDC 24VDC and 125VDC dual source leads to the 48V DC 24VDC amp 125VDC power terminal block on the Magnum 6Ks Switch shown in Figure to the right The 48VDC terminal block on the Magnum 6KQ Switch is located on the left front of the unit next to the Alarm terminal block and is g7 DC terminal equipped with five
35. eeeseeeeeeeeeeeeeeeeeaes 6 2 2 Product Description Magnum 6KQ Field Switch eee 7 22D Four Port Copper Module 6KQ4 RJ45 oo eeeeeseeseeeeeeeeeees 10 2 23 PoE power pass through model P6KQ4 RJ45 10 100Mb 4 port 10 224 Two Port Fiber Modules 2 1OOMb fiber cee eee eee 11 225 Two Port 10 Mb mm Fiber ST Modulles ccccceeeeeeeees 12 2 2 6 SFP Gigabit LOOOMbps port modules 0 0 0 ceeeeeeeeeeeees 12 2 2 7 Packet Prioritization 802 1p QOS ccsssssssssseesseeeeeeeeeees 13 2 2 8 Frame Buffering and Flow Control cccccccccssssssseeeseeeeeeeeees 13 2 2 9 Managed Network Software MNS 6K for 6KQ Series 14 2 Features and Benefis eissintasdsocesnnstthas soucsdenenweldeiabacshivedssedaicdaaatandensouansntes 15 ZA PPC AMONG secon EEE 16 3 0 DDS CEA reann E 19 3 1 Locating Magnum 6KQ Switches cc csssssesssssseeseeeeeeeeeeeeeeeaaas 19 3 2 Connecting Ethernet Medid scissioni insni eari 20 3 2 1 Connecting Fiber Optic ST type twist lock ec eeeeees 20 3 22 Connecting Fiber Optic SC type Snap In ee eeeeeeeees 21 3 2 3 Connecting Single Mode Fiber Optic ssnsnssssssesoeeeeeeesssssssssss 21 3 2 4 Connecting Twisted Pair CAT3 CATS ccceeeeseeeseeeeeeeeees 21 3 2 5 Connecting Twisted Pair CATSe or better 0 0 eeeeeeeeeeeees 22 3 2 6 Gigabit SFP Small Form factor Pluggable ceeeeeeees 23 3 3 DIN Rail Mounting
36. elded and shielded twisted pair cables 1 JOOOBASE T connections require that all four pairs or wires be connected Insert either end of the cable with an RJ 45 plug into the RJ 45 connector of the port Note that even though the connector is shielded either unshielded or shielded cables and wiring may be used 2 Connect the other end of the cable to the corresponding device 3 Use the LINK LED to ensure proper connectivity by noting that the LED will be illuminated when the unit is powered and proper connection is established _ www GarrettCom com 22 Magnum 6KQ Managed Field Switch Installation and User Guide 04 07 3 2 6 Gigabit SFP Small Form factor Pluggable Optical Transceivers The small form factor pluggable SFP is a compact optical transceiver used in optical communications for both telecommunication and data communications applications Due to its compact hot pluggable characteristics SFPs are becoming a very popular choice for various applications The small chassis Magnum 6KQ is designed for industry standard Gb SFPs and Gb SFPCU copper for user selection of the SFP gigabit media type as desired All SFPs used in Magnum 6KQs are compliant with the industry standard Multi Source Agreement MSA ensuring compatibility with a wide range of networking kit Bail clasp Side View Duplex LC connector Front view Note It is highly recommended to remove the fiber cable first before removing the SFP
37. eon GarrettCom Industrial Networking at Its Best Magnum 6KQ Managed Field Switch Hardware Installation and User Guide Magnum 6KQ Managed Field Switch Installation amp User Guide 04 07 Magnum 6KQ Managed Field Switch Hardware Installation and User Guide Part 84 00180Z Rev A Trademarks Ethernet is a trademark of Xerox Corporation NEBS is a trademark of Telcordia Technologies UL is a registered trademark of Underwriters Laboratories GarrettCom Magnum and Personal Switch are trademarks and Personal Hub is a registered trademark of GarrettCom Inc Important The Magnum 6KQ Managed Field Switch contains no user serviceable parts Attempted service by unauthorized personnel shall render all warranties null and void If problems are experienced with Magnum 6KQ Switch products consult Section 6 Troubleshooting of this User Guide Copyright 2007 GarrettCom Inc All rights reserved No part of this publication may be reproduced without prior written permission from GarrettCom Inc Printed in the United States of America www GarettCom con Magnum 6KQ Managed Field Switch Installation amp User Guide 04 07 Contacting GarrettCom Inc Please use the mailing address phone and fax numbers and email address listed below GarrettCom Inc 47823 Westinghouse Dr Fremont CA 94539 7437 Phone 510 438 9071 Fax 510 438 9072 Website http www GarrettCom com email support garre
38. er Input nominal 88 to 150VDC range Standard 6KQ DC Power Input Terminal Block GND See also Section 1 0 Technical Specifications for the 6KQ base unit B2 0 48VDC 24VDC and 125VDC POWER THEORY OF OPERATION The 48VDC 24VDC and HUB SUPPLY POWER SWITCH 125VDC power options are designed using diodes inside on each DC power A input line behind the two external power A connection terminals so that the power CHASSIS GND GND from an external source can only flow into the hub This allows the Switch to operate only whenever DC power is correctly applied to the two inputs It protects the Switch from incorrect DC input connections An incorrect polarity connection for example will neither affect the Switch its internal power supply nor will it blow the fuse in the internal power supply B3 0 APPLICATIONS FOR DC POWERED ETHERNET SWITCHES Magnum 6KQ Switches are easily installed in a variety of applications where 48VDC 24 or 125VDC power is used as the primary power source The DC power configuration capability provides an Ethernet networking solution utilizing a special power supply in switches with a proven track record The 48 VDC solution is particularly useful in the telecommunication industry where it is common for facilities to operate on 48VDC power Such companies include regular and wireless telephone service providers Internet Service Providers ISPs and _ www GarrettCom com 46
39. er ports support fiber cabling distances according to the IOBASE FL and 1OOBASE FX standards i e 2km distance for multi mode fiber Single mode for greater distances may be available as a special order request quote 2 2 6 SFP Gigabit L000Mbps port modules The Gigabit port options for the modular slot come in a few different configurations of Fiber SFP s or RJ 45 s The Magnum 6KQ offers only SFPs Small Form Pluggable for Gigabit speed There are multiple choices of SFP Gigabit transceiver types to combine with RJ 45 s for the modular slot Up to two Gigabit ports max can be configured in the modular slot D only An example of a two Gb module is the 6KQ 2GSFP SFP fiber An example of a single Gigabit module is the 6KQ 1GCU 10 100 1000Mb RJ 45 ports A combo option of Gigabit copper and SFP fiber 6KQ 2GSFPCU is shown below in the figure 1 10 100 1000Mb RJ 45 1 1000Mb SFP The 6KQ Modules provide an SFP opening for insertion of industry standard SFP transceivers to provide Gigabit Gb media flexibility Gigabit SFP modules are available in both multi mode 550m and single mode 10 25 40 70 km fiber options as well as a Gigabit copper option _ www GarrettCom com a 12 Magnum 6KQ Managed Field Switch Installation and User Guide 04 07 There are three LEDs mounted on each Gigabit port module The Gigabit fiber has LEDs that indicate F H Full Half duplex LK Link status and ACT receiving activity on
40. f all the modules and options see Section 1 2 NOTE The 6KQ modules can only be configured at the factory 2 2 1 Four port SFF fiber modules 6KQ4 MTRJ 6KQ4 MLC 100Mb fiber Fig 2 2 1 SFF Fiber a 1 2 3 4 EELA RLE 6KQ4 MTRJA ALK O LK LK 6KQ4MLC or below 1 2 3 4 ACT AC F H F ACT AC In a four port SFF Small Form Factor fiber port module all of the fiber ports rH LK A OLK O LK E LK F are of the same speed 100Mb mode and connector type Small Form Factor SFF Fiber Ports come in multi mode forms MT RJ or LC type connectors and single mode form LC type connectors The 100Mb fiber four port modules for the Magnum 6KQ s normally are set factory default to operate in full duplex mode for best fiber distance and performance Using the 6K MNS software the user may select full or half duplex mode per port through set port command The set up of the software See Magnum 6K MNS Software Manual gives the user flexibility to adapt to any FDX or HDX type of Fast Ethernet devices There are three LED s per fiber port The Link LK LED indicates ready for operation on that port when lit The F H LED indicates operation in full duplex mode when ON half duplex when OFF The blinking ACT LED indicates receiving Activity _ www GarrettCom com a 9 Magnum 6KQ Managed Field Switch Installation and User Guide 04 07 on the port A fiber cable must be connected into a SFF port and t
41. g Use only with Listed 10 A circuit breaker provided in building installation Complies with FDA radiation performance standards 21 CFR subchapter J or equivalent Fastening torque of the lugs on the terminal block 9 inch pound max Centralized DC Power Source cable securement use at least four cable ties to secure the cable to the rack at least 4 inches apart with the first one located within 6 inches of the terminal block Se au C6 0 ORDERING INFORMATION To order the optional Dual Source 48VDC power supply factory installed order Dual Src48V as a separate line item following the product model Example Magnum 6KQR 48VDC Dual Src 48V_ forthe regular DS model Similarly order the Dual source 24VDC or Dual source 125VDC as a separate line item following the product model Example Magnum 6KQ 24VDC or Magnum P6KQ 125VDC Dual Sre24V for regular models Or Dual Src125V Switch See the Configuration Guide on the GCI web site at http www garrettcom com techsupport insertion_guides 6kqcg pdf for additional information C7 0 OPERATION Operation of the Dual Source Magnum 6Ks 48 VDC 24VDC and 125VDC Switch models are identical to that of the standard models 50
42. has achieved It is set as AUTO by default All other LEDs are the same as the SFP fiber 42 Magnum 6KQ Managed Field Switch Installation and User Guide 04 07 5 2 12 6KQ BLNK The 6KQ BLNK is a blank face plate or cover plate that must be installed in any empty 6KQ PM slot to maintain proper cooling air flow safety etc Two screws underneath the front panel hold the 6KQ BLNK in place 6 0 TROUBLESHOOTING All Magnum Ethernet products are designed to provide reliability and consistently high performance in all network environments The installation of a Magnum 6KQ Switch is a straightforward procedure see INSTALLATION Section 3 0 The operation is also straightforward and is discussed in Section 4 Should problems develop during installation or operation this section is intended to help locate identify and correct these types of problems Please follow the suggestions listed below prior to contacting your supplier However if you are unsure of the procedures described in this section or if the Magnum 6KQ Switch is not performing as expected do not attempt to repair the unit instead contact your supplier for assistance or contact GarrettCom Customer Support 6 1 Before Calling for Assistance 1 If difficulty is encountered when installing or operating the unit refer back to the Installation Section of the applicable chapter of this manual Also check to make sure that the various components of the network are interope
43. hat the LED will be illuminated when the unit is powered and proper connection is established NOTE for Power Substations In support of the IEEE 1613 Class 2 standard GCI advises that for substation applications the RJ 45 ports are intended for connectivity to other communication equipment such as routers or telecommunication multiplexers installed in close proximity i e less than 2 meters or 6 5ft to the 6KQ It is not recommended to use these ports in substation applications to interface to field devices across distances which could produce kigh greater than 2500V levels of ground potential rise GPR during line to ground fault conditions The 6KO passes the 161 3specifications for zero packet loss with fiber ports amp with RJ45 ports used as indicated here 3 2 5 Connecting Twisted Pair CATS5e or better Unshielded or Shielded The RJ 45 Gigabit ports of the Magnum 6KQ can be connected to the media types LOOOBASE T or CAT 5E or better 100 ohm UTP or shielded twisted pair STP balanced cable The CAT 5E or better 100 ohm UTP or shielded twisted pair STP balanced cable is recommended to use when making 1 OOOBASE TX connections In either case the max distance for unshielded twisted pair cabling is 100 meters 328 ft Media IEEE Standard Connector Twisted Pair CAT 5e 1000BASE T RJ 45 The following procedure describes how to connect a LOOOBASE T twisted pair segment to the RJ 45 port The procedure is the same for both unshi
44. he DC leads to the Switch s power terminals positive and negative screws The use of Ground GND connects to the Switch chassis screw provided under the DC terminal Ensure that each lead is securely tightened NOTE Always use a voltmeter to measure the voltage of the incoming power supply and figure out the ve potential lead or ve potential lead The more ve potential lead will connect to the post labeled ve and the rest to the ve The GND can be hooked up at the last When power is applied the green PWR LED will illuminate Note The GND should be hooked up first The 6KQ unit has a floating ground so the user may elect to Ground either or terminal to suit the customer s use Before connecting hot lines to the Terminal Block of 48VDC 24VDC or 125VDC always use a digital voltmeter to measure the output voltage of the power supply and determine the lead which is more ve potential The more ve voltage lead from 48V or 48V supply must be connected to the post labeled B4 1 UL Requirements for DC powered units Minimum I8SAWG cable for connection to a Centralized DC power source Minimum 14AWG cable for connection to a earthing wiring Use only with Listed 10 A circuit breaker provided in building installation a oe i Ee Complies with FDA radiation performance standards 21 CFR subchapter J or equivalent ad Fastening torque of the lugs on the terminal block 9 inch pou
45. he Link LK indicator for that port must be ON indicating there is a powered up device at the other end of the cable in order for a LK LED to provide valid indications of operating conditions on that port 2 2 2 Four Port Copper Module 6KQ4 RJ45 The 6KQ s 4 port Copper module model 6K4 RJ45 provides four 10 100Mb switched RJ 45 ports The 10 100Mb switched ports normally as a default setting are independently N way auto negotiating and auto crossover MDIX for operation at 10 or 1OOMb speed in full or half duplex mode 1 e each independently selects a mode and speed to match the device at the other end of the twisted pair cable See Section 4 3 for auto negotiation and MDIX details On the model 6KQ RJ45 module there are four LEDs for each port two integrated into the connector and two below the connector The LK Link LED indicates ready for operation on that port when lit The blinking ACT Activity LED indicates receiving Activity on that port when lit The 10 100 LED indicates operation at 100Mb speed when ON and at 10 Mb speed when OFF when auto negotiation is not disabled The FDX HDX LED is ON to indicate full duplex operation and OFF to indicate the half duplex mode A twisted pair cable must be connected into an RJ 45 port and the Link LK indicator for that port must be ON indicating there is a powered up device at the other end of the cable in order for a LK LED to provide valid indications
46. ing IEEE 802 1x Port based Network access control TEEE802 3af Power over Ethernet Maximum 10 Mbps Ethernet Segment Lengths Unshielded twisted pair 100 m 328 ft Shielded twisted pair 150 m 492 ft 1OBASE FL multi mode fiber optic 2 km 6 562 ft 1OBASE FL single mode fiber optic 10 km 32 810 ft Maximum Standard Fast Ethernet Segment Lengths 10BASE T CAT 3 4 5 UTP 100 m 328 ft 100BASE TX CAT 5 UTP 100 m 328 ft Shielded twisted pair 150 m 492 ft 1O00BASE FX half duplex multi mode 412 m 1350 ft 1O0BASE FX full duplex multi mode 2 0 km 6 562 ft 1OOBASE FX half duplex single mode 412 m 1350 ft 1OOBASE FX full duplex single mode 20 0 km 66KQ ft 1OOBASE FX full duplex Long Reach 40 0 km 122K ft Maximum Standard Gigabit Ethernet Segment Lengths 1000BASE T CAT5e or higher is recommended 100 m 328 ft 1O00BASE SX full duplex multi mode 62 5um cable 220m _ www GarrettCom com a l Magnum 6KQ Managed Field Switch Installation and User Guide 04 07 1OOOBASE SX full duplex multi mode 50um cable 550m 1OOOBASE LX full duplex single mode 62 5um cable 5Km Fiber Multi mode connector types supported Fiber Port ST type twist lock Fiber multi mode 1OMb 1LOBASE FL Fiber Port MTRJ type plug in SFF Fiber multi modelOOBASE FX Fiber Port SC type snap in Fiber optic multi mode 1OOBASE FX Fiber Port ST type twist lock Fiber optic m mode 1OOBASE FX Fiber Port LOO
47. ingle mode fiber connectors Follow the steps listed in Section 3 2 2 above 3 2 4 Connecting Twisted Pair CAT3 CATS Unshielded or Shielded The RJ 45 ports of the Magnum 6KQ can be connected to the following two media types 100BASE TX and LOBASE T CAT 5 cables should be used when making 100BASE TX connections When the ports are used as IOBASE T ports CAT 3 may be used In either case the maximum distance for unshielded twisted pair cabling is 100 meters 328 ft Media IEEE Standard Connector Twisted Pair CAT 3 4 5 1O0OBASE T RJ 45 Twisted Pair CAT 5 1OOBASE TX RJ 45 _ www GarrettCom com 21 Magnum 6KQ Managed Field Switch Installation and User Guide 04 07 NOTE Jt is recommended that high quality CAT 5 cable be used whenever possible in order to provide flexibility in a mixed speed network since 10 100 copper switched ports are auto sensing for either 10 and 1OOMD s The following procedure describes how to connect a LOBASE T or 1OOBASE TX twisted pair segment to the RJ 45 port The procedure is the same for both unshielded and shielded twisted pair cables 1 Using standard twisted pair media insert either end of the cable with an RJ 45 plug into the RJ 45 connector of the port Note that even though the connector is shielded either unshielded or shielded cables and wiring may be used 2 Connect the other end of the cable to the corresponding device 3 Use the LINK LED to ensure proper connectivity by noting t
48. ll other ports in a Magnum 6KQ but local traffic on a port will not consume any of the bandwidth on any other port The Magnum 6KQ units are plug and play devices There is no software configuring necessary to be done for basic operation at installation or for maintenance The only hardware configuration settings are user options for an UP LINK Switch resides inside the unit on the 6KQ RJ45 There is an optional Half Full duplex mode and 10Mbps or 100Mbps selection for the switched ports which must be configured through MNS software per unit as per the requirement The internal functions of both are described below Filtering and Forwarding Each time a packet arrives on one of the switched ports the decision is taken to either filter or to forward the packet Packets whose source and destination addresses are on the same port segment will be filtered constraining them to that one port and relieving the rest of the network from having to process them A packet whose destination address is on another port segment will be forwarded to the appropriate port and will not be sent _ www GarrettCom com a 30 Magnum 6KQ Managed Field Switch Installation and User Guide 04 07 to the other ports where it is not needed Traffic needed for maintaining the un interrupted operation of the network such as occasional multi cast packets is forwarded to all ports The Magnum 6KQ Switches operate in the store and forward switching mode which eli
49. ly to indicate a trouble condition The ports will still operate properly for data traffic _ www GarrettCom com 41 Magnum 6KQ Managed Field Switch Installation and User Guide 04 07 6KQ 2GSFPCU 1 Port 10 100 1000Mbps 1 Port at 1000Mb SFP G unk 1070071000 3 acriviry 4 FULLMALE 5 2 11 SFPs Gigabit 1000Mbps port modules The Magnum 6KQ offers a Gigabit option with multiple choices of copper 10 100 1000Mbps or Gigabit SFP Fiber modules for the modular slot While up to two Gigabit modules maxm can be configured in the modular slot D only The 6KQ Modules provide a GBIC opening for insertion of industry standard SFPs to provide Gigabit Gb media flexibility SFP fiber Transceivers are available with both multi mode 550m at 850nm and single mode at 1330nm 10 25 40 70 km fiber options and for Gigabit copper as well with new models appearing often The 1000Mb Gigabit SFP fiber port modules on the Magnum 6KQ are normally set factory default to operate at AUTO mode for best fiber distance and performance Only two Gigabit ports can be configured on a Mangum 6KQ managed switch in slot D There are three LEDs provided on each SFP Gigabit port module The SFP Gigabit fiber has LEDs that indicate LK Link status and ACT receiving activity when lit and F H on for Full and OFF for half duplex for that port The copper Gigabit port supports 10 100 1000Mb speeds The three LED s show the speed the connection
50. m managed switches to provide a very effective and reliable solution The modularity feature to support both copper and fiber at either 10 100 1000Mb speeds easily meets the various speeds of legacy and future broadband requirements In a fast growing secure video environment the 6KQ is a reliable and secure solution The modular design of the Magnum 6KQs provide a wide range of copper fiber options to meet requirements The Gigabit uplink for storage or broadband uplink allows the telecom user a very effective solution to store their sensitive data securely Fig 2 4c Magnum 6KQs deployed in a video security CCTV application for monitoring and securing the premises 3 0 Installation Before installing the equipment it is necessary to take the following precautions 1 If the equipment is mounted in an enclosed or multiple rack assembly the steady state long term environmental temperature around the equipment must be less than or equal to 60 C 2 If the equipment is mounted in an enclosed or multiple rack assembly adequate airflow must be maintained for proper and safe operation 3 If the equipment is mounted in an enclosed or multiple rack system placement of the equipment must not overload or load unevenly the rack system 4 If the equipment is mounted in an enclosed or multiple rack assembly verify the equipment s power requirements to prevent overloading of the building s electrical circuits 5 If the equipment is mou
51. minates bad packets and enables peak performance to be achieved when there is heavy traffic on the network Address Learning All Magnum 6KQ units have address table capacities of 4K node addresses suitable for use in larger networks They are self learning so as nodes are added removed or moved from one segment to another the 6KQ Switch automatically keeps up with node locations An address aging algorithm causes least used addresses to fall out in favor for frequently used addresses To reset the address buffer cycle power down and up 4 2 Status LEDs For Magnum 6KQ models 6KQ PWR Power LED ON when external power is applied to the unit LK Steady ON Link status for 10 Mbps and 100Mbps operation ACT ON with port activity for 10 Mbps and 100Mbps operation F H Full Half duplex LED ON when the port is running full duplex OFF for half duplex 100 10 Speed LED ON when the speed is 100Mbps OFF when the speed is 10 Mbps 4 3 Auto Cross MDIX and Auto negotiation for RJ 45 ports The RJ 45 ports independently support auto cross MDI or MDIX in auto negotiation mode and will work properly with all the other connected devices with RJ 45 ports whether they support Auto negotiation e g 10Mb Hub media converter or fixed mode at 10Mb or 100Mb Half Full Duplex managed switch or not No cross over cable is required while using the 6KQ s copper port to other devices Operation is according to the IEEE 802 3u sta
52. mponents in the products that prove to be defective at no charge other than shipping and handling provided that the product is returned pre paid to GarrettCom This warranty will not be effective if in the opinion of GarrettCom the product has been damaged by misuse misapplication or as a result of service or modification other than by GarrettCom GarrettCom reserves the right to make a charge for handling and inspecting any product returned for warranty repair which turns out not to be faulty Please complete the warranty card as this acts as a product registration and mail it to GarrettCom within two weeks of your purchase 45 Magnum 6KQ Managed Field Switch Installation and User Guide 04 07 APPENDIX B DC Power Input B1 0 Specifications for Magnum 6KQ Switches DC Power at 24V and 48V and 125V DC Power input Each Magnum Model 6KQ Managed Switch requires DC power input at either 24VDC 48VDC or 125VDC nominal The wide range of DC power input types qualifies this product for use in 24VDC 48VDC as well as 125VDC applications in different industries DC Power Terminals are internally floating so that user may ground either GND ground wire connection to the 6KQ chassis screw Power Consumption 35 watts typical for a fully loaded fiber model 12 watts typical for a small 4 port copper only model 24VDC Power Input nominal 18 to 36VDC range 48VDC Power Input nominal 36 to 60 VDC range 125VDC Pow
53. much as 2 Km see Power Budget Section 4 5 Each port has an Activity ACT LED indicating packets being received a Link LK LED that indicates proper connectivity with the remote device when lit and a FDX HDX LED to indicate full duplex mode when lit or half duplex when off The 10 100 LED indicates 100Mbps speed when lit and at 1 OMbps speed when off 5 2 5 6KQ4 MT 4 100Mb multi mode FX MTRJ Small Form factor Magnum 6KQ4 MT is a multi mode fiber optic 4 port module equipped with a small form factor MTRJ type connector It looks almost like an RJ 45 port but it is black in color The MT RJ s small compact size connector and ease of connection make it a good choice for 6KQ4 MT 4 100 Mb MTRJ Fiber Port 100Mbps fiber to the desktop Ethernet 2 3 connectivity When L L J LJ i O LK o LK installed in a Magnum 6KQ Switch it supports 2 Activity fiber optic cable distances up the IEEE standard 100Mbps distance limits 1 e typically 2km at full duplex or half duplex 38 Magnum 6KQ Managed Field Switch Installation and User Guide 04 07 The functionality of this 1OOBASE FX multi mode 4 port module is essentially the same as the ST and SC types It has 6KQ4 RJMT the same LEDs per port indicating port 2 Port 10 100Mbps amp 2 port 100Mbps MTRJ Fiber port activity ACT Link LK and FDX or HDX operation 5 2 6 6KQ4 RJMT COMBO 2 10 100Mbps RJ 45 and 2 100Mb multi mode FX MTRJ
54. nd max 6 Centralized DC Power Source cable securement use at least four cable ties to _ www GarrettCom com a 47 Magnum 6KQ Managed Field Switch Installation and User Guide 04 07 secure the cable to the rac k at least 4 inches apart with the first one located within 6 inches of the terminal block B5 0 OPERATION Operation of Magnum 6KQ Switches with the optional 48 VDC 24VDC and 125VDC dual source power input is identical to that of the standard single source DC powered models B6 0 TROUBLESHOOTING Please refer to Section 6 0 for troubleshooting APPENDIX C Internal DC Dual Source Power Input Option C1 0 SPECIFICATIONS FOR MAGNUM 6KQ FIELD SWITCH Power Supply Internal 48VDC Dual Source DC Power Connector First Source A he 2nd Source B B GND ground wire connection to the hub chassis screw Input Two separate sources each at 36 60 VDC Power Supply Internal 24VDC Dual Source model Dual Src 24V DC Power Connector First Source A a ae 2nd Source B B GND ground wire connection to the hub chassis screw Input Two separate sources each at 18 36 VDC Power Supply Internal 125VDC Dual Source model Dual Src 125V DC Power Connector First Source A BAe 2nd Source B B GND ground wire connection to the hub chassis screw Input Two separate sources each at 88 150 VDC With the exception of the dual DC input power connection
55. ndard The Managed 6KQ s Fast Ethernet copper ports can be set for either fixed 100Mb speed or for 10 100 F H N way auto negotiation per the IEEE802 3u standard The selection is made via MNS software The factory default setting is for auto negotiation At 1OMb or 100Mb fixed speed the user may select half or full duplex mode by MNS Software for each RJ 45 port separately For detail information See Section 2 2 9 at page no 14 of 31 Magnum 6KQ Managed Field Switch Installation and User Guide 04 07 this manual to access the 6K MNS Rel 3 Software user guide One frequently used application for the Managed Magnum 6KQ Switch copper ports is to connect one of them using a fiber media converter to another Switch in the network backbone or to some other remote 100Mb device In this case it is desirable to operate the fiber link at 1OOMb speed and at either half or full duplex mode depending on the capabilities of the remote device Standard commercially available Fast Ethernet media converters mostly do not support auto negotiation properly and require that the switched port to which they are connected be at the 1OOMb fixed speed Attachments to a 10 100 auto negotiation port typically will not work properly The 6KQ Switch s RJ 45 ports handle this situation by configuring the ports as per desired through MNS software port settings and can check the port status of each port after the change When Magnum 6KQ RJ 45 copper ports
56. ndwidth support of 10 100 and 1000Mb The user can utilize the SNMP feature equipped with VLAN RMON STP and other standard managed LAN features to provide a secure and stable network The 6KQ Managed Fiber with S ring and Link Loss Learn features easily fulfill the redundant requirement with a secure and fast reconfiguration time for cable breakup when set up in a ring topology The Gigabit port option boosts the bandwidth for high speed to support the peak traffic and minimize congestion Magnum 6K25 E metal E my SNMP TAA ee Monitor IBER Connection FIBR Connection it el B TA Magnum Magn m 6K A Fig 2 4b Magnum 6KQ equipped with S Ring in redundant ring solution _ ww GarettCom com a 18 Magnum 6KQ Managed Field Switch Installation and User Guide 04 07 Example 3 In another application in an industrial environment a 12 port Nebs compliant 24VDC managed switch is required to meet the fiber and copper connections to cover the wider area of video CCTV The switch must be SNMP enabled and managed to easily monitor the whole setup The Magnum managed field switch easily qualifies for this requirement with the various features and modularity it has Loaded with MNS 6K management software the field switch provides a very effective and economical solution for the video vignette environment The security features e g port security VLANs SNMPv3 secure telnet etc also boost the Magnu
57. normally received from the factory with all required 6K Port Modules installed NOTE There may be situations where the 6K PMs need to be added or replaced Any change in configuration of the modules can be done only via factory installation There is no field upgrade option for 6KQ port modules Please contact Tech Support support garrettcom com RMA rma garrettcom com for changing modules The 6KQ port modules are not compatible with or inter changeable with the other Magnum 6K Family Switches PMs which use larger typically 8 port modules 3 7 Connecting a Management Console Terminal to Magnum 6KQ Serial RJ45 Console Port The serial console port on the Magnum 6KQ is different from other 6K family switches The Serial RJ 45 port as shown in the picture requires an 8 pin RJ 45 male connector to have the proper communication Note the serial RJ 45 console port on the Magnum 6KQ is compatible with Cisco type RJ 45 console port cables The Serial port pin out for the RJ 45 console port used on Magnum 6KQ TT Pin Name Description 8 oo 1 RTS Request To Send OUT 8 pin RI45 3 TXD Transceiver Data OUT female connector 4 GND Ground at the Magnum 5 GND Ground 6KQ front panel Q P 6 RXD Receive Data Female 8 CTS Clear To Send Male connector Pin out info for 6KQ RJ 45 female connector connector 8 1 kisi Front 8 pin RJ45 male connector at the cables 29 Magnum 6KQ Managed Field Swi
58. nted in an enclosed or multiple rack assembly verify that the equipment has a reliable and uncompromised earthing path This section describes installation of the Magnum 6KQ Switches as well as connection of the various Ethernet media types 3 1 Locating Magnum 6KQ Switches For vertical panel mounting and wall mounting see Section 3 3 1 For vertical DIN Rail mounting see Section 3 3 _ www GarrettCom com 19 Magnum 6KQ Managed Field Switch Installation and User Guide 04 07 For DC power input data see Appendix B For Dual Source see Appendix C The rugged metal case of the Magnum 6KQ will normally protect it from accidental damage in a lab or workplace setting Maintain an open view of the front to visually monitor the status LEDs Keep an open area around the unit so that cooling can occur from convection while the unit is in operation The 6KQ has no fans so it is silent when in operation Internal electronics use the case as a heat sink so the unit may normally be quite warm to the touch 3 2 Connecting Ethernet Media The Magnum 6KQ Switches are specifically designed to support all standard Ethernet media types within a single Switch unit This is accomplished by using a family of different Port Modules which can be individually selected and configured per slot See Section 2 2 for a description of the PMs The various media types supported along with the corresponding IEEE 802 3 802 3D 802 3u 802 3AB and 802 3
59. ode FX SC type S l M The Magnum 6KQF 2SSCL is also a Fiber module equipped with 2 Single mode Long Reach SC type connectors It provides a long reach Fiber function in one module to the 6KQ Switches supporting 100Mb single mode Long Reach fiber network segments The 6KQF 2SSCL when installed in a Magnum 6KQ Switch supports single mode fiber cable lengths of as much as 40 Km see Power Budget 6KQE 2SSCL 2 100 Mb SSC Fiber Port Section 4 5 Each port has an Activity ACT LED indicating packets being received a Link LK LED indicating proper connectivity with the remote device when lit and a FDX HDX LED indicating full nee duplex mode when lit or half duplex when off 37 Magnum 6KQ Managed Field Switch Installation and User Guide 04 07 5 2 4 6KQ3 RJMSC COMBO 2 10 100Mbps RJ 45 Ports and 1 100Mbps Multi mode i RJMSC FX SC type snap in SREO FETS connector 2 Port 10 100Mbps amp 1 port 100Mbps MultiMode Fiber port The Magnum 6KPQ RJMSC is also a Combo module equipped with 2 dual speed copper ports and 1 Multi mode SC type connector It provides an advantage through LINK 10 100 combining copper and Fiber functions in one module that 3 ACTIVITY 4 FULL HALF supports two copper and one multi mode fiber network segments The 6KQ3 RJMSC when installed in a Magnum 6KQ Field Switch operates on copper at 100m distances The Fiber is multi mode and cable lengths can be as
60. ower Input nominal 88 to 150VDC range Std Terminal Block GND Power Consumption 35 watts typical for a fully loaded fiber model _ www GarrettCom com 2 Magnum 6KQ Managed Field Switch Installation and User Guide 04 07 12 watts typical for a small 4 port copper only model DC DUAL POWER SOURCE OPTIONAL For DC internal power supplies at 48VDC 24VDC and 125VDC with the Dual Source option for continuity of operation when either of the DC input sources are interrupted see Appendices B and C Dual Source Terminal Block A B A B 6KQ Mounting Vertical mounting normal Suitable for wall or DIN Rail mounting 6KQ Agency Approvals and Standards Compliance UL listed UL60950 cUL CE Emissions meet FCC Part 15 Class A NEBS Level 3 and ETSI Compliant IEEE 1613 Class 2 Environmental Standard for Electric Power Substations See also Note for Power Substations in Section 3 2 4 3 7 and 5 2 9 IEC 61850 EMC and Operating Conditions Class C for Power Substations NEMA TS 2 and TEES for DC powered and PoE powered traffic control equipment Class Division 2 and ATEX for hazardous locations pending Warranty Three years per UL 60950 temperature rating Made in USA See the Configuration Guide on the GCI web site at http www garrettcom com techsupport insertion_guides 6kqcg pdf for configurations and options Email info GarrettCom com for additional information Magnum 6KQ Managed Field
61. ptions Each Magnum 6KQ base unit may be configured with a choice of 3 modular slots Following modules can be configured in Slot B and D Slot C is 100Mb Fiber only Magnum 6KQ Port Modules 6KQ4 RJ45 TP Module w four 10 100Mbps copper ports P6KQ4 RJ45 PoE 6KQ module four 10 100 copper ports with PoE on data pairs may be configured in slot B only 6KQ4 RJMLC 2 2 module w two RJ 45 ports and two 2km mm LC connectors 6KQ4 RJSLC 2 2 module w two RJ 45 ports and two 15km Sgl m LC connectors 6KQ4 RJMT 2 2 module w two RJ 45 ports and two 2km mm MTRJ connectors 6KQ2 10ST Two 1OMb mm Fiber 2km FL ST s 6KP4 MLC SFF mm Fiber module w four 100Mb mm FX LC connectors 6KP4 MT SFF mm Fiber module w four 1OOMb mm FX MT RJ connectors 6KQ2 MST Two 100Mb Fiber module w four 1OOMb 2km FX ST connectors 6KQ3 RJMSC 2 1 module w two RJ 45 ports and one 2km mm FX SC s 6KQ2 MSC Two 100Mb Fiber module w four 1OOMb 2km FX SC connectors 6KQ2 SSC Two 100Mb Fiber module SM w 100Mb 20km FX SC connectors 6KQ2 SSCL Two 100Mb Fiber module SM w 100Mb 20km FX SC connectors Fiber only Slot C configuration choices _ www GarrettCom com jg 4 Magnum 6KQ Managed Field Switch Installation and User Guide 04 07 6KQF 4MT 4 ports module w four 1OOMb mm 2km FX MTRJ s fiber ports 6KQF 4MLC 4 ports module w four 1OOMb mm 2km FX LC s fiber ports 6KQF 4SLC 4 ports module w four 1OOMb Sm 15km FX LC s fiber port
62. rable 2 Check the cables and connectors to ensure that they have been properly connected and the cables wires have not been crimped or in some way impaired during installation About 90 of network downtime can be attributed to wiring and connector problems J Make sure that DC power is properly attached to each Magnum 6KQ Switch unit Use the PWR LEDs to verify each unit is receiving power 4 If the problem is isolated to a network device other than the Magnum 6KQ Switch product it is recommended that the problem device be replaced with a known good device Verify whether or not the problem is corrected If not go to Step 5 below If the problem is corrected the Magnum 6KQ Switch and its associated cables are functioning properly 5 If the problem continues after completing Step 4 above contact your supplier of the Magnum 6KQ Switch unit or if unknown contact GarrettCom Inc by fax phone or email support garrettcom com for assistance _ www GarrettCom com a 43 Magnum 6KQ Managed Field Switch Installation and User Guide 04 07 6 2 When Calling for Assistance Please be prepared to provide the following information 1 A complete description of the problem including the following points a The nature and duration of the problem b Situations when the problem occurs c The components involved in the problem d Any particular application that when used appears to create the problem 2 An accurate list of Garre
63. reed MNS 6K managed networks software featuring GUI ease of use Secure Web Management SNMPv2 v3 management 802 1p QoS Prioritization Tag based VLANs IGMP Snooping and IGMP L2 multicast management port security RADIUS and TACACS support and a choice of redundancy options including RSTP and GarrettCom s rapid ring recovery S Ring and RS Ring products See the Managed Networks Software MNS 6K datasheet for more information Magnum 6KQs are ideal for building a switched hardened Ethernet network infrastructure connecting edge devices such as PLCs and IEDs with upstream switches or routers Designed for use in industrial applications such as factory floors and control cabinets industrial video surveillance systems with PoE power utility substations tariffed carrier field facilities or transportation and oil and gas the rugged Magnum 6KQ handles stressful workloads mixes of bursty data traffic and priority streaming traffic as well as harsh environmental conditions Advanced thermal design techniques with ribbed surface Aluminum cases for maximum heat dissipation and a sealed case design enables the unit to operate in harsh Industrial grade environments efficiently Heavy duty Ethernet Switch jobs are readily accommodated with an extended temperature rating of 40 C to 60 C by the UL Component Parts method or 50 C to 85 C by the IEC 60068 Type Test method With options such as several popular DC power input type
64. s 6KQF 2MST 2 ports module w two 1OOMb mm 2km FX ST s fiber ports 6KQF 2MSC 2 ports module w two 100Mb mm 2km FX SC s fiber ports 6KQF 2SSC 2 ports module w two 100Mb Sm 20km FX SC s fiber ports 6KQF 2SSCL 2 ports module w two 100Mb Sm 40km FX SC s fiber ports 6KQF 2MLC 2 ports module w two 1OOMb mm 2km FX LC s fiber ports 6KQF 2SLC 2 ports module w two 100Mb Sm 15km FX LC s fiber ports 6KQF 2MT 2 ports module w two 1OOMb mm 2km FX MTRJ s fiber ports 6KQF IMST 1 port module w one 100Mb mm 2km FX ST s fiber ports 6KQF 1IMSC 1 port module w one 100Mb mm 2km FX SC s fiber ports 6KQF 2SSC 1 port module w one 100Mb Sm 20km FX SC s fiber ports 6KQF 1SSCL 1 port module w one 100Mb Sm 40km FX SC s fiber ports 6KQ BLNK Blank cover for 1 un used 6KQ module slot Gigabit 1000Mb module choices slot D only 6KQ 2GSFP SFP Gig module w two SFP pluggable open transceiver ports 6KQ 2GCU Copper Gig module w two10 100 1000 RJ 45 ports 6KQ 2GSFPCU Copper Gig module w one SFP pluggable open transceiver port one10 100 1000 RJ 45 ports 6KQ 1GSFP SFP Gig module w one SFP pluggable open transceiver ports 6KQ 1GCU Copper Gig module w one10 100 1000 RJ 45 ports Gigabit L000Mb SFP Small Form Pluggable Transceiver _option 6KQ SFP SX Giga SFP transceiver 1 OOOMb SX 850nm wavelength 500m SFP LX10 Giga SFP transceiver 1 O
65. s optional AC power and DIN Rail mounting the hardened Magnum 6KQ is a multi purpose Industrial Ethernet Switch _ www GarrettCom com a 7 Magnum 6KQ Managed Field Switch Installation and User Guide 04 07 The 6KQ managed switches also provide PoE options via power inside PoE modules on one of A B or C slots and allows the users to select a wide option of combo PoE modules to support 802 3af pd devices See details for POE modules in sec 5 2 10 The Power Sourcing Equipment PSE is fully compatible with Powered Devices PD e g wireless access points IP phones that comply with the IEEE 802 3af PoE standard The PoE switch ports have an auto sensing algorithm so that they provide power only to 802 3af PoE end devices PoE is managed by a multi stage handshake to protect equipment from damage and to manage power budgets The PoE ports will discontinue supplying power when the PoE powered devices are disconnected This feature supports the 802 3af PoE PSE standard for over current protection under current detection and fault protection High performance features include non blocking unicast traffic speed on all ports and 802 1p QoS Traffic Prioritization Magnum 6KQ switches are plug and play and are designed for use in connecting edge devices such as PLCs IEDs and PoE video cameras with upstream switches and routers where a mix of bursty data traffic and priority streaming traffic for video surveillance and
66. s and the power supply all specifications and configuration options for the Magnum 6KQ 48VDC 24VDC and 125VDC models with this Dual Source option are identical to those listed in the Magnum 6KQ Field Switches Installation and User Guide including Appendix B Internal DC Power Supply Option C2 0 MAGNUM 6KQ with 48VDC 24VDC and 125VDC Dual Source option The 6KQ Switch models with the internal 48VDC 24VDC and 125VDC Dual Source power supply are designed for installations where a battery plant is the power source and where two separate power sources are utilized in order to increase operational uptime and to simplify maintenance The functionality of the Magnum 6KQ Switch 48VDC 24VDC and 125VDC Dual Source Option units is identical to the standard AC powered models Refer to the main sections of this Installation and User Guide for a detailed description of the Magnum 6KQ Switches www GarrettCom com NN 48 Magnum 6KQ Managed Field Switch Installation and User Guide 04 07 C3 0 DUAL SOURCE OPTION THEORY OF OPERATION The Dual Source DC power option is designed using diodes inside of the chassis on each DC power input line A diode is placed in each of the B four input lines behind the four B external power connection terminals CHASSIS CND GND so that power from an external source can only flow into the unit This allows the unit to operate whenever DC power is correctly applied to either or both of th
67. s is a collision based flow control mechanism when operating at half duplex only When the Switch detects that its free buffer queue space is low the Switch prevents more frames from entering by forcing a collision signal on all receiving half duplex ports in order to stop incoming traffic 2 2 9 Managed Network Software MNS 6K for Magnum 6KQ Series Magnum 6KQ s come with Rel3 6 licensed MNS 6K software which allows the user to configure the Magnum 6KQ as a Managed Switch and implements security features and other software enabled features NOTE Magnum 6KQ managed switch will work with Rel 3 6 firmware or higher version only using any other MNS 6K version will not support the hardware For additional information about MNS 6K see the Magnum MNS 6K Software User guide in pdf format a separate document normally accessible via your web browser at ftp ftp garrettcom com or FTP client program at ftp GarrettCom com using user m6kuser password m6kuser All MNS 6K software information including new releases and upgrades related to MNS 6K software can be accessed and download from GarrettCom s FTP site Alternatively for the latest documentation and information or needed GarrettCom s MIBs for SNMP visit www GarrettCom com techsupport index htm software and look for the Magnum MNS 6K info For interactive training software which shows basic and advanced info about the Magnum MNS 6K management software and for a u
68. seful tool for first time users visit Magnum MNS 6K Operator Training You may also email info GarrettCom com for further information 14 Magnum 6KQ Managed Field Switch Installation and User Guide 04 07 2 3 Features and Benefits Managed switching for high performance Ethernet LANs Magnum 6KQ Switches provide unicast non blocking all ports can run at full speed at once performance with standard Managed Network Software MNS 6K included They are typically used in LAN traffic centers with up to 12 1OOMb 2 Gigabit ports for backbone connections where managed network services are desired Switching services includes 802 1p QoS packet prioritization The Magnum 6KQ switching hardware supports QoS giving packet processing priority to priority tagged packets according to the IEEE 802 1p standard For port and application specific priorities of data the QoS software may be configured Features Fiber Built In Magnum 6KQ Managed Field Switches are designed to naturally include fiber ports and support mixes of multi mode single mode 10Mb 1OOMb and 1000Mb speed full and half duplex classic Small Form Factor SFF and GBIC fiber connectors RJ 45 10 100 ports can also be configured in the mix of port types S Ring RS Ring and Link Loss Learn for reliable high availability using ring topology S Ring RS Ring combined with the Link Loss Learn feature provides reliable fast recovery of a fault in a ring topology Relay Con
69. stallation and User Guide 04 07 The cable end is a plug in connector with both fiber strands terminated in one housing that cannot be improperly inserted Each port has an Activity ACT LED indicating packets being received a Link 6KQ4 RJMLC LK LED indicating proper connectivity 2 Port 10 100Mbps amp 2 port 100Mbps MLC Fiber port with the remote device when lit and a FDX HDX LED indicating full duplex mode when lit or half duplex when off 5 2 8 6KQ4 RJMLC Combo 2 100Mbps multi mode LC small form factor and 2 10 100 C4 LINK 2 10 100 Mbps RJ 45 Connector ACTIVITY 4 FULL HALF The Magnum 6KQ4 RJMLC module is a combo module with a combination of copper and mm Fiber Small Form Factor LC type ports The small size of LC connectors allows more ports on one module The 6KQ4 RJMLC is equipped with two 10 100 RJ 45 ports and two LC multi mode fiber ports When installed ina Magnum 6KQ Switch it supports the standard distances as per the media Each port has an Activity ACT LED indicating packets being received a Link LK LED that indicates proper connectivity with the remote device when lit and a FDX HDX LED to indicate full duplex mode when lit or half duplex when off The 10 100 LED indicates 100Mbps speed when lit and at 10Mbps speed when off 5 2 9 6KQ4 RJ45 Twisted Pair 10 100Mb 4 Port The 6KQ4 RJ45 module supports Ethernet twisted pair segments of any sanaan length It is equipped 6KQ4 RJ4
70. t with space for air movement around the top and the sides typically a minimum of inch Note that the metal brackets supplied hold the back of the 6KQ unit out from the panel or wall behind it creating a rear space of about inch or lcm This allows _ www GarrettCom com a 26 Magnum 6KQ Managed Field Switch Installation and User Guide 04 07 air circulation and cooling of the rear part of the case For best cooling of the 6KQ attach the metal brackets to metal rather than wood or plastic Attaching to metal helps conduct heat away from the 6KQ through the metal brackets and into the metal support structure Since the 6KQ has special internal thermal techniques patent pending to move the heat generated by the electronic components inside into the case the case may be quite warm to the touch during normal operation 4 56 Fad fe g BFF O M gt ca i m i O dE ai t D uG w 0 O N N o wh RJ LOCATIONS The unit is mounted using the brackets as shown in the illustration above The spacing for the mounting screws into the supporting wall or panel is a rectangle 21 74 x 11 91 cm 8 56 x 4 69 inches center to center 3 4 Powering the Magnum 6KQ Managed Field Switch The DC internal power supply supports installation environments where the DC voltage is from 18 to 150 volts depending on the model selected The power _ www GarrettCom com a 27 Magnum 6KQ Managed Field Switch Installation and User Guide 04 0
71. tacts for monitoring internal power and user defined software events Two Alarm Relay contacts monitor basic operations One is for hardware and will signal loss of power internally The other is software controllable and will signal user defined software events such as a security violation or an S Ring fault condition Vertical mounting for efficient convection cooling no fans extended temp Mounting brackets for vertical mounting are included DIN Rail mounting hardware is optional Ethernet signal and power cables attach at the bottom Two sets of status LEDs are included one set viewable at the port connector and one set viewable from the front Standard AC power input 48VDC or 24VDC or 125VDC input is optional Standard AC power input comes with an IEC plug and is auto ranging for worldwide use For special applications models with 48VDC or 24VDC or 125VDC are available Dual Source DC input can also be selected and configured on the DC power input models Heavy duty design for Industrial Ethernet and extended temperature operation Fiber ports take more power than copper ports but the Magnum 6KQ design provides for this with heavy duty components The ambient temperature dual rating is 60 C per UL methods and 95 C per type test methods MNS 6K licensed Management Software included S Ring RS Ring optional MNS 6K includes SNMP Switch Management with secure access control RMON CLI Port Security Port Mirroring secured Radius
72. tch Installation and User Guide 04 07 The Hyper terminal configuration is exactly the same as all other 6K Family managed switches Please check the following URL for details http www garrettcom com techsupport software userguides mns6k_CLI pdf NOTE The console RJ 45 Serial cable may be ordered from the GCI factory using the model number and description here CONSOLE CBLQD Console attachment cable serial null modem cable with one side RJ 45 for the 6KQ and a male DB 9 Female connector on the other end CONSOLE CBLQU Console attachment cable serial null modem cable Combo with one serial RJ 45 for the 6KQ side and a USB cable connector option on the other end e g computer NOTE for Power Substations In support of the IEEE 1613 Class 2 standard GCI advises that for substation applications the serial RJ 45console_ports are intended for temporary connectivity to other equipment such as PCs Since the console port connection is temporary it is excluded from IEEE 1613 packet loss testing per the 1613 standard defined test procedure 4 0 OPERATION This chapter describes the functions and operation of the Magnum 6KQ Switch 4 1 Switching Functionality A Magnum 6KQ provides switched connectivity at Ethernet wire speed among all of its ports The Magnum 6KQ supports10 100Mbs for copper media and 10 or 100Mb separate traffic domains for fiber ports to maximize bandwidth utilization and network performance All ports can communicate to a
73. the Magnum 6KQe sssssssssssssseeennesssessssssssssssse 25 3 3 1 Mounting Dimensions for 6KQ with metal brackets 26 3 4 Powering the Magnum 6KQ Managed Field Switch ee 27 3 5 Alarm Contacts for monitoring internal power and Software Traps 28 3 6 6KQ Port Module 6KPM Installation 2 0 0 0 eee cceeecceeeeeeeeeeeees 29 3 7 Connecting a Management Console Terminal to 6KQ eee 29 We OPERATION epee renerrey erent EAA rrr yen 30 4 1 Switching Functionality ccccccccccccccccccseesssseeeeeeeeeeeeeeeeseeeeaeeeeeeeeees 30 4 2 SoCs LE DS erciecscacssacsitedsicubesauecht ytanienbuacniasunscnsnetadantacdeincnessbbadacestncaades 31 4 3 Auto Cross MDIX and Auto negotiation for RJ 45 ports 31 4 4 Flow control IEEE 802 3x standard 2 00 0 eee ceeceeceeccecceccecceeceeceecs 33 4 5 Power Budget Calculations for 6KQ PM s with Fiber Media 33 5 0 Introduction Magnum 6KQ Managed Field Switch Port Modules35 5 1 Inspecting the Package and Product cc ccsessssssseeeeeeeeeeeeeeeeeeeaees 35 5 2 6KPM Module DeScription scsssseeeeecececceeeeeaasseeseseseeeeeeeees 35 5 2 1 6KQF 2MST Combo Module cecccceesecccesecceeeseceeenees 36 5 2 la 6KQ2 10ST 2 10Mb multi mode FX ST twist lock Module36 www GarrettCom com Ban Magnum 6KQ Managed Field Switch Installation amp User Guide 04 07 5 2 2 OKOP 2MSC Fiber connector soscccssiciccnsatinsscta
74. top of the DIN Rail Then snap the latches into holding position by moving the bottom of the 6KQ inwards to a vertical position The DIN Rail latches and brackets are heavy duty and will hold the 6KQ securely in position even with cabling attached to the unit To release the 6KQ from the DIN Rail mounting press the top of the two DIN Rail latches down simultaneously to release the 6KQ so that it can be dismounted by pulling the bottom out Once the bottom of the 6KQ is rotated out the DIN Rail latch is not engaged and the 6KQ can be moved up and out free of the DIN Rail mounting The picture in Section 3 3 shows vertical mounting of Magnum 6KQ as it about to be mounted on a DIN Rail track for proper convection cooling of the unit Note that there is air space in the rear as the 6KQ unit is held out from the rear of the panel by the mounting brackets The 6KQ design uses the case for cooling patent pending and needs to be mounted vertically with air flow space around it in the front rear and sides The DIN Rail mounting brackets and latches are optional and need to be ordered as separate items e g Model DIN RAIL 6KQ 3 3 1 Mounting Dimensions for 6KQ with metal brackets Each Mangum 6KQ is supplied with metal mounting brackets and screws to mount the unit securely on a panel or wall It is recommended to mount the 6KQ vertically as shown below for proper cooling and long life reliability It is also advisable to mount the uni
75. transceiver for any reason Not removing the fiber cable first can damage the fiber cable cable connector or optical interfaces It is advised not to remove and insert a SFP transceiver frequently as this may shorten its useful life one Note Always use an ESD wrist strap while handling the SFP transceivers since the SFP modules are static sensitive devices Note The copper 1OOOBASE T SFP transceiver port supports 1000Mb only It is recommended to use a straight through RJ 45 4 twisted pair connection while connecting to any Server workstation While connecting with any Switch repeater or other device it is recommended to use Crossover RJ 45 4 twisted pair category 5 or higher cabling The maximum length supported on copper 1OOOBASE T is 100mts 328 ft 23 Magnum 6KQ Managed Field Switch Installation and User Guide 04 07 The various SFPs transceivers supported by GarrettCom 6KQs D slot are Gb Modules fixed ports SFP Gb SFP fiber optic transceivers SFP SX Gb SX 850nm wavelength 500 m distance SFP LX10 Gb LX 1310nm wavelength 10km dist SFP LX25 Gb LX 1310nm wavelength 25km distance SFP ZX40 Gb ZX 1550nm wavelength 40km distance SFP ZX70 Gb ZX 1550nm wavelength 70km distance 3 2 6a Connecting Fiber Optic Cable to SFP Transceivers 1 Before connecting the fiber optic cable remove the protective dust caps from the tips of the connectors on the PM Save these dust caps for future use
76. ttCom product model s involved with serial number s Include the date s that you purchased the products from your supplier a It is useful to include other network equipment models and related hardware including personal computers workstations terminals and printers plus the various network media types being used 4 A record of changes that have been made to your network configuration prior to the occurrence of the problem Any changes to system administration procedures should all be noted in this record 6 3 Return Material Authorization RMA Procedure All returns for repair must be accompanied by a Return Material Authorization RMA number To obtain an RMA number please use this URL https rma garrettcom com rma rma_request_noaccount php to fill out the form Please have the following information readily available Name and phone number of your contact person Name of your company institution Your shipping address Product name Serial Number or Invoice Number Packing List Number or Sales Order Number Date of installation Failure symptoms including a full description of the problem GarrettCom will carefully test and evaluate all returned products will repair products that are under warranty at no charge and will return the warranty repaired units to the sender with shipping charges prepaid see Warranty Information Appendix A for complete details However if the problem or condition causing the re
77. ttcom com Federal Communications Commission Radio Frequency Interference Statement Radio Frequency Interference Statement This equipment generates uses and can radiate frequency energy and if not installed and used properly that is in strict accordance with the manufacturer s instructions may cause interference to radio communication It has been tested and found to comply with the limits for a Class A computing device in accordance with the specifications in Subpart J of Part 15 of FCC rules which are designed to provide reasonable protection against such interference when operated in a commercial environment Operation of this equipment in a residential area is likely to cause interference in which case the user at his own expense will be required to take whatever measures may be required to correct the interference Canadian Emission This Class A digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations Cet appareil respecte toutes les exigences du R glement sur le mat riel du Canada Cet appareil est Classe A an Magnum 6KQ Managed Field Switch Installation amp User Guide 04 07 MTS OL Contents sssaaa EEEa ESES ERATKAN Page LO SPECIFICATIONS aeiiaaie a aei 1 1 1 Technical SPC MCA OWS esere En EEE EAEE l 1 2 Ordering Information cccccccessssssssssseececceceeeeeeeeaaeaaaaaessssseeeeeeeeess 4 MAVEN BNO a 6 ZA Inspecting the Package and Product c cc ccesscssssse
78. turn cannot be duplicated by GarrettCom the unit will be returned as No Problem Found GarrettCom reserves the right to charge for the testing of non defective units under warranty Testing and repair of product that is not under warranty will result in a customer user charge 6 4 Shipping and Packaging Information Should you need to ship the unit back to GarrettCom please follow these instructions www GarrettCom com NNT 44 Magnum 6KQ Managed Field Switch Installation and User Guide 04 07 1 Package the unit carefully It is recommended that you use the original container if available Units should be wrapped in a bubble wrap plastic sheet or bag for shipping protection You may retain all connectors and this Installation Guide CAUTION Do not pack the unit in Styrofoam popcorn type packing material This material may cause electro static shock damage to the unit 2 Clearly mark the Return Material Authorization RMA number on the outside of the shipping container 3 GarrettCom is not responsible for your return shipping charges 4 Ship the package to GarrettCom Inc 47823 Westinghouse Dr Fremont CA 94539 7437 Attn Customer Service APPENDIX A WARRANTY INFORMATION GarrettCom Inc warrants its products to be free from defects in materials and workmanship for a period of three 3 years from the date of shipment by GarrettCom During this warranty period GarrettCom will repair or at its option replace co
79. z standards and connector types are as follows IEEE Standard Media Type Max Distance Port Module Fiber 100BASE FX mm Fiber 220m ft GBIC SXSC sel m Fiber 5Km GBIC LXSC 100BASE FX mm Fiber 2 0km 6 562 ft 6K4 MSC MST sgl m Fiber 18 0km 95K ft SSC SSCL small form factor mm Fiber 2 0km 6 562 ft 6KQ MTRJ MLC small form factor sgl m Fiber 15 km 6KP4V SLC Copper 1OBASE T and 1OOBASE TX twisted pair100m 328 ft 6KQ RJ45 1000BASE TX twisted pair 100m 328 ft GBIC TP mm multi mode sol m single mode 3 2 1 Connecting Fiber Optic ST type twist lock The following procedure applies to installations using a PM with ST type fiber connectors This procedure applies to ports using a 6KQ module MST type port 1 Before connecting the fiber optic cable remove the protective dust caps from the tips of the connectors on the PM Save these dust caps for future use _ www GarrettCom com a 20 Magnum 6KQ Managed Field Switch Installation and User Guide 04 07 2 Wipe clean the ends of the dual connectors with a soft cloth or lint free lens tissue dampened in alcohol Make certain the connectors are clean before connecting Note One strand of the duplex fiber optic cable is coded using color bands at regular intervals you must use the color coded strand on the associated ports at each end of the fiber optic segment 3 Connect the Transmit TX port light colored post on the Magnum PM to the Receive RX port of th