Home
GarrettCom FT14 User's Manual
Contents
1. 2 An accurate list of GarrettCom product model s involved with serial number s Include the date s that you purchased the products from your supplier _www GarrettCom com s s s 50 FT14 and FT14H 10Mb Media Converters Installation and User Guide 09 04 3 It is useful to include other network equipment models and related hardware including personal computers workstations terminals and printers plus the various network media types being used 4 A record of changes that have been made to your network configuration prior to the occurrence of the problem Any changes to system administration procedures should all be noted in this record 5 3 Return Material Authorization RMA Procedure All returns for repair must be accompanied by a Return Material Authorization RMA number To obtain an RMA number please use this URL https rma garrettcom com rma rma_request_noaccount php to fill out the form Please have the following information readily available Name and phone number of your contact person Name of your company institution Your shipping address _www GarrettCom com s s 51 FT14 and FT14H 10Mb Media Converters Installation and User Guide 09 04 Product name Serial Number or Invoice Number Packing List Number or Sales Order Number Date of installation Failure symptoms including a full description of the problem GarrettCom will carefully test and evaluate all returned pr
2. C depending on the power source used The FT14H is suitable for temperature un controlled outdoor applications Mounting options include panel mounting DIN rail or rack mount tray The FT14 series Media Converters offer a graceful way to convert and transmit data among twisted pair and Fiber Multi or Single Mode network cabling environments FT14 Media Converters cost significantly less than full repeaters and can be used whenever media distance limitations will not be exceeded in the segment _www GarrettCom com s s _ _ 11 FT14 and FT14H 10Mb Media Converters Installation and User Guide 09 04 All units are compatible with Ethernet V 1 0 2 0 specifications and comply with IEEE 802 3 standards Twisted Pair 10BASE T o Fiber optic ST Connector 10BASE FL and Magnum FT14 10Mb s Media Converter 12 FT14 and FT14H 10Mb Media Converters Installation and User Guide 09 04 The up link or crossover switch on the RJ 45 port simplifies cable installation All fiber models operate in transparent full or half duplex mode supporting matched sets of either mode type i e attached devices are either both full duplex or both half duplex Magnum FT 14 series 10Mb Media Converters are designed for quick and easy installation even in very tight spaces Media cables are easily attached to the corresponding Media Converter or any other device Using the Uplink Switch feature elimina
3. 1 0 SPECIFICATIONS 1 1 Technical Specifications Model FT14 FT14H multi mode and single mode Performance Data Rate 10 Mbps IEEE 802 3 half duplex mode Network Standards Ethernet Ethernet V1 0 2 0 IEFE 802 3 10BASE T 10BASE FL IEEE 802 3 Magnum Media Converters are physical layer standard Ethernet products and operate independently of all software Number of Media Converters in series Experience shows that up to three units can be used in series between repeaters For 4 or more in series noise build up will typically preclude proper operation FT14 and FT14H 10Mb Media Converters Installation and User Guide 09 04 Maximum Standard Ethernet Segment Lengths 10BASE T twisted pair 100 m 328 ft 10BASE FL Fiber optic 2 0 km 6 562 ft 10BASE FL Single mode Fiber optic 10 0 km 32 810ft Note for single mode HDX collision domain limits may restrict distances to about 5km Note Magnum Media Converters DO NOT support full length Ethernet segments See Section 3 2 of this manual for media lengths and segment distance calculations Operating Environment Ambient Temperature 0 C to 50 C FT14 Hd Hi FT14S Hd Hi 40 C to 55 C FT14H Hd Hi FT14SH Hd Hi 40 C to 75 C FTI4H 9VDC FT14SH 9VDC FT14H 24VDC FT14SH 24VDC FT14H 48 VDC FT14SH 48VDC Cold start down to 25 C Storage Temperature 40 C to 100 C 40 F to 212 F ww GarettCom com s 2 FT14 and FT14H 10Mb Media Co
4. FT14 series Media Converters a rack mount tray is available MC14 TRAY The Media Converter units are mounted with their RJ 45 port and DC power jack in the back with either fiber or BNC cable in the front Any mix of the FT14 type Media Converters may be placed on a tray up toa maximum of 16 units The mounting spaces of the MC14 TRAY are FT14 and FT14H 10Mb Media Converters Installation and User Guide 09 04 specific to the 14 series and do not permit other models A typical installation of the model MC14 TRAY 19 rack mount tray will hold a few often three to eight 14 series Media Converters with their power supplies plugged into power strips not included in the rear area of the tray Metal mounting screws in the bottom front hold the Media Converters firmly in place The beveled top edge of the units permits the LEDs of each unit to be viewed for operational status even when the units are very close together 3 3 MC14 TR PS9 amp MC14 TR PS9X2 for Rack Mounting Media Converters The MC14 TR PS9 and MC14 TR PS9X2 are another option available for Rack Mounting the mix match of 10Mbps and 100Mbps Media Converters together in 19 rack mount tray These models comes with built in common universal AC power supply rated at 55 watts at 50 C ambient 9VDC output and supporting up to 10 MC for _www GarrettCom com 5s s 26 FT14 and FT14H 10Mb Media Converters Installation and User Guide 09 04
5. and ETSI compliant H Model IEEE P1613 Env Std for Electric Power Substations H Model NEMA TS 2 and TEES for traffic control equipment H Model designed for UL 2043 above the ceiling installation IEC61850 EMC and Operating Conditions Class C for Power Substations Warranty Three years return to factory Made in USA www GarrettCom com s lt se 6 FT14 and FT14H 10Mb Media Converters Installation and User Guide 09 04 1 2 Summary of models and descriptions FT14 Hd TP to 10Mb mm Fiber ST external 115 60Hz AC power supply for 0 to 50 C FT14 Hi TP to 1OMb mm Fiber ST external 230 50Hz AC power supply for 0 to 50 C FT14H Hd TP to 10Mb mm Fiber ST external 115 60Hz AC power supply for 40 to 55 C FT14H Hi TP to 10Mb mm Fiber ST external 230 50Hz AC power supply for 40 to 55 C FT14H 9V DC TP to 1OMb mm Fiber ST 12V DC Internal power supply 40 to 75 C FT14H 24V DC TP to 1OMb mm Fiber ST 24V DC Internal power supply 40 to 75 C FT14HR 24V DC TP to mm Fiber 24V DC Internal pwr supply 40 to 75 C includes DIN Rail FT14H 48V DC TP to 1OMb mm Fiber ST 24V DC Internal power supply 40 to 75 C For a Single mode 10Mb Fiber ST model insert S after the number 14 in each line above MC14 TRAY 19 Rack mount tray for 14 series Media Converters up to 16 units DIN RAIL MC2 Metal DIN Rail mounting bracket for one FT14 Series Media Converter FT14 and FT14H 10Mb Media Converters Inst
6. equipment is being installed in un controlled temp environment and require longer distance Magnum FT 14 series Media Converters have an external AC power supply and internal DC Power supply enabling them to be used to convert signals among media that does not have a power source as part of the cabling system such as twisted pair and Fiber Equipped with wide variety of options of AC and DC power supply and components for higher un controlled temp qualify the FT14 s for use in office locations as well as industrial and even outdoor applications www GarrettCom com s _ s gt 18 FT14 and FT14H 10Mb Media Converters Installation and User Guide 09 04 In this application in a Industrial environment where extended temp supported units is a requirement the existing Twisted pair network can be easily connected to longer distance through fiber media using Magnum FT 14 or FT14H 10 Mb media converters 10Base T Ethernet Segmen Expanding longer distance through Fiber optic 19 FT14 and FT14H 10Mb Media Converters Installation and User Guide 09 04 2 5 Full Half duplex capability For 1OMb FT14 series Media converters the twisted pair to fiber combination is capable of full duplex i e simultaneously transmitting and receiving on the same cable segment operation Full duplex is rarely required at 1OMb but might occasionally be desired to connect a 1OMb RJ 45 Switching Hub port over a fiber link to a full d
7. not exceed 100 Note 2 If the total segment distance calculation result is greater than 100 consider using a Magnum Repeater so that each cable type can be 100 of its maximum allowed length Note 3 The maximum number of 10Mb Media Converters that can be used in series is three The cumulative noise from four or more units together causes packet alignment errors _www GarrettCom com s s 33 FT14 and FT14H 10Mb Media Converters Installation and User Guide 09 04 3 6 Connecting Ethernet Media Connecting Ethernet media to the Magnum FT 14 Series Media Converter is very simple and straightforward Using proper media segment simply attach the cable end to the appropriate connector See Sections 4 4 for details of the LEDs on the media converter models 3 6 1 Connecting Twisted Pair RJ 45 ports The following procedure describes how to connect a 1OBASE T twisted pair segment to the RJ 45 port on the Magnum Media Converters The procedure is the same for both unshielded and shielded twisted pair segments 1 Using standard 1OBASE T media insert either end of the cable with an RJ 45 plug into the RJ 45 connector of the Magnum Media Converter ww GarrettCom com jg 34 FT14 and FT14H 10Mb Media Converters Installation and User Guide 09 04 2s Connect the other end of the cable to the corresponding device Use the LINK LED to ensure proper connectivity by noting that the LED will be illuminated when th
8. 0 cccsscssscsssscscesscescssesesssencssesecessssssnessssnessesnessesessoes 39 4 1 Power Requirements Power Supply Types for FT14 and FT14H 39 4 2 Powering the FT14H DC Direct power input ee eee 41 4 3 FT14H DC powered Installation 0 00 eee ceeeeesseceneeceeeceeeeeceeeeeneers 43 4 4 Dual LEDs front panel and side panel Magnum FT14 FT14H 45 4 5 Up Link Cross over Switch eeccesecsseceeececseceeeeecnaeeeeeeeceaeeeeneees 46 5 0 TROUBLESHOOTING sseseseesssesesceeosoeseseseecesosoeseseeecorseseeeeoeeosoeseeeseee 47 5 1 Before Calling for Assistance eceeecceseescseecreeeeeseceeeeneeeeeaeeees 48 5 2 When Calling for Assistance 0 cc ceeecesescsseeeeeecseeecnecaeeseeeeeeeeaees 50 5 3 Return Material Authorization RMA Procedure c ccceeceeeees 51 5 4 Shipping and Packaging Information eee eceeeseeseeeecneeeeceeteeeeeees 54 APPENDIX A WARRANTY INFORMATION scccssssssssssssscssessssees 55 FT14 and FT14H 10Mb Media Converters Installation and User Guide 09 04 Revisions Rev A 09 04 Minor updates on UL Requirements power supplies Rev A 06 04 Minor updates on Agency approvals and power supplies Rev A 05 03 Initial release of this user manual for FT14 and FT14H GarrettCom Inc reserves the right to change specifications performance characteristics and or model offerings without notice vi FT14 and FT14H 10Mb Media Converters Installation and User Guide 09 04
9. 100 30 FT14 and FT14H 10Mb Media Converters Installation and User Guide 09 04 Twisted Pair 1 OBASE T Fiber optic ST Connector 10BASE FL and FOIRL Magnum FT14 10Mb s Media Converter Connectivity between Fiber and TP Ethernet Media 31 FT14 and FT14H 10Mb Media Converters Installation and User Guide 09 04 Media Distance Formula for Magnum Media Converters X Y lt 100 Where X The segment distance on one side of the Magnum Media Converter divided by the Standard Maximum Media Distance for that media type x 100 Where Y The segment length on the other side of the Magnum Media Converter divided by the Standard Maximum Media Distance for that media cabling type x 100 A Distance Calculation Example Connectivity between ThinNet and TP Ethernet Media In the figure shown above the length of Segment X is 780m 2574 ft This is 39 of the maximum allowable distance for 1OBASE FL media 2Km 780 2000 x 100 39 The length of Segment Y is 55m 165 ft This is 55 of the maximum _www GarrettCom com s s ss 32 FT14 and FT14H 10Mb Media Converters Installation and User Guide 09 04 allowable distance for UTP 1OBASE T media 100 m 55 100 x 100 55 The total of the two percentages 39 55 is 94 which is allowable Note 1 Where more than one media converter is used in one segment run the percentages for all of the cabling lengths in the run must be added together and must
10. Corporate Headquarters GarrettCom Inc 47823 Westinghouse Dr Fremont CA 94539 Phone 510 438 9071 Fax 510 438 9072 Website http www GarrettCom com email support garrettcom com eo GarrettCom Ethernet at Its Best MagnumFT14 and FT14H 10Mb s Media Converters Installation and User Guide FT14 and FT14H 10Mb Media Converters Installation and User Guide 09 04 Magnum FT14 and FT14H 10Mb s Media Converters Installation and User Guide Part 84 00134 Rev A 09 04 Trademarks Ethernet is a trademark of Xerox Corporation NEBS is a trademark of Telcordia Technologies UL is a registered trademark of Underwriters Laboratories GarrettCom Magnum and Personal Switch are trademarks and Personal Hub is a registered trademark of GarrettCom Inc Important The Magnum FT14 and FT14H 10 Mb s Media Converters contains no user serviceable parts Attempted service by unauthorized personnel shall render all warranties null and void If problems are experienced with Magnum FT14 FT14H 10 Mb s Media Converters products consult Section 5 Troubleshooting of this User Guide Copyright 2003 GarrettCom Inc All rights reserved No part of this publication may be reproduced without prior written permission from GarrettCom Inc Printed in the United States of America i FT14 and FT14H 10Mb Media Converters Installation and User Guide 09 04 Federal Communications Commission Radio Frequency Interference S
11. Installation and User Guide 09 04 2 3 Features and Benefits mM Reduces Network Costs Magnum Media Converters offer the ideal solution to efficiently and inexpensively connect Twisted Pair with 10Mb Fiber media within an expanding Ethernet network where full repeaters are not required E No added Repeater Hop Count Media Converters do not add signal timing delays associated with full repeaters and can be installed without increasing the repeater hop count of an existing network E Fiber twisted pair models for all fiber modes A variety of twisted pair to fiber models provide for multi mode or single mode fiber transparent full or half duplex mode ST connectors www GarrettCom com s 5s s 15 FT14 and FT14H 10Mb Media Converters Installation and User Guide 09 04 E Two sets of LEDs for viewing status from any angle Each FT14 Media Converter is equipped with a two sets front and side of LEDs to provide status information when viewed at any angle or mounting arrangement rack mount MC14 Tray or wall mount E Rugged metal case Industrial grade FT14 Media Converters have a robust design and are packaged in a rugged sheet metal enclosures to ensure high reliability and durability even when placed in extended temp e g industrial or outdoor applications E AC and DC Power Supplies with extended temperature ratings FT14 amp FT14H Media Converters are designed for use in temperature un controlled applications and are
12. K on each port enabling an installer to see the LINK or no LINK status of each port and each piece of cable independently This is nice for the network installer but it introduces a discontinuity for the managed network software which wants to see through the media converter treating it as part of Www GarrettCom com 21 wisted Pair Two Link LEDs one for each Cable segments RJ 45 amp Fiber FT14 and FT14H 10Mb Media Converters Installation and User Guide 09 04 the cable attached to a managed switch port The Link Pass through in the FT14H models provides the LINK see through feature desired for managed networks On the FT14H models either both LINK LEDs are lit or neither is lit And the FT14 and FT14H s both operate in transparent half and full duplex mode Twisted Pair Note that a pair of FT14 or FT14H media converters in series can be used to go from an RJ 45 port through a fiber segment and into another RJ 45 port Where both media converters are FT14H s with Link Pass through the LINK on each RJ 45 port can see through both of the FT14H s Media Converters to the other RJ 45 port as illustrated in this diagram Two LINK LED s both ON or both OFF www GarrettCom com 22 FT14 and FT14H 10Mb Media Converters Installation and User Guide 09 04 3 0 INSTALLATION This section describes the installation of the Magnum FT14 series Media Converters including loca
13. MC14 TR PS9 and 16 units of Fiber media converters for MC14 TR PS9X2 The MC14 TR PS9X2 Model has two groups of eight units per power supply These models are equipped with auto ranging AC input to the power supplies for use worldwide The MC mounting spaces of the MC14 TR models are specific to the Magnum 10Mbps FT 14 and TB14 and 100Mb 14E series and do not permit other models to be put in the tray 27 FT14 and FT14H 10Mb Media Converters Installation and User Guide 09 04 The side view picture shown here above is an example of an installation of the model MC14 TR PS9 19 rack mount tray holding a few 10Mbps FT 14 s and 100Mb 14E Media Converters each with their power input plugged into the built in common AC power supply in the rear area of the tray PS units that come with the MC s are not used Metal mounting screws in the bottom front hold each of the media converters secure in the tray separately removable for service The dual LEDs permit viewing operating status of the Media Converters from any angle 3 4 DIN Rail mounting option The Magnum FT14 and FT14H Media Converters designed for use in Factory Floor Industrial Ethernet environments are also available for DIN Rail mounting in an enclosure having DIN Rails _www GarrettCom com s s 28 FT14 and FT14H 10Mb Media Converters Installation and User Guide 09 04 The metal DIN Rail mounting hardware is optional and needs to b
14. OOTING All Magnum Ethernet products are designed to provide reliability and consistently high performance in all network environments The installation of Magnum FT14 SERIESs 10 Mb s Media Converters is a straightforward procedure see INSTALLATION Section 3 0 the operation is also straightforward and is discussed in Section 4 Should problems develop during installation or operation this section is intended to help locate identify and correct these types of problems Please follow the suggestions listed below prior to contacting your supplier However if you are unsure of the procedures described in this section or if the Magnum FT14 FT14H 10 Mb s Media Converter is not performing as expected do not attempt to repair the unit instead contact your supplier for assistance or contact GarrettCom Customer Support _wwv GarrettCom com 47 FT14 and FT14H 10Mb Media Converters Installation and User Guide 09 04 5 1 Before Calling for Assistance 1 If difficulty is encountered when installing or operating the unit refer back to the Installation Section of the applicable chapter of this manual Also check to make sure that the various components of the network are interoperable 2 Check the cables and connectors to ensure that they have been properly connected and the cables wires have not been crimped or in some way impaired during installation About 90 of network downtime can be attributed to wiring and connector pro
15. T14 and FT14H 10Mb Media Converters Installation and User Guide 09 04 4 Ship the package to GarrettCom Inc 47823 Westinghouse Dr Fremont CA 94539 Attn Customer Service APPENDIX A WARRANTY INFORMATION GarrettCom Inc warrants its products to be free from defects in materials and workmanship for a period of three 3 years from the date of shipment by GarrettCom During this warranty period GarrettCom will repair or at its option replace components in the products that prove to be defective at no charge other than shipping and handling provided that the product is returned pre paid to GarrettCom _www GarrettCom com s _ s gt 55 FT14 and FT14H 10Mb Media Converters Installation and User Guide 09 04 This warranty will not be effective if in the opinion of GarrettCom the product has been damaged by misuse misapplication or as a result of service or modification other than by GarrettCom GarrettCom reserves the right to make a charge for handling and inspecting any product returned for warranty repair which turns out not to be faulty Please complete the warranty card as this acts as a product registration and mail it to GarrettCom within two weeks of your purchase 56
16. a graceful way to convert and transmit data between twisted pair and Fiber network cables for media flexibility in new or expanded 10Mb Ethernet networks The future proof fiber comes as ST connector with Multi or Single Mode options They provide standard collision detection and indication and comply with the Ethernet V1 0 2 0 specifications and the IEEE 802 3 standards Power consumed in use is 1 5 to 2 watts _www GarrettCom com s gt 9 FT14 and FT14H 10Mb Media Converters Installation and User Guide 09 04 The FT14 regular package units are for office and wiring closet environments and use an external AC power supply A metal case with convection cooling is featured Magnum FT14 10Mb s Media Converter Magnum FT14H Hardened 10Mb s Media Converter Magnum FT14 Magnum FT14H www GarrettCom com 10 FT14 and FT14H 10Mb Media Converters Installation and User Guide 09 04 Operation may be in 0 to 50 C ambient temperature The units can be mounted securely on a closet wall or metal cabinet or by using the metal panel mounting clips included The FT14H Hardened unit features a sealed metal case which is also used as a heat sink No air inflow is required for cooling so the FT14H resists dust dirt moisture smoke and insects and is plenum rated Choices of models for external AC or internal DC power are available Storage temperature rating is up to 40 C to 75
17. allation and User Guide 09 04 2 0 INTRODUCTION This section describes the FT14 and FT14H models including appearance features and typical applications 2 1 Inspecting the Package and the Product Examine the shipping container for obvious damage prior to installing this product notify the carrier immediately of any damage which you believe occurred during shipment or delivery Inspect the contents of this package for any signs of damage and ensure that the items listed below are included This package should contain 1 Magnum FT14 or FT14H mm or single mode Media Converter Unit 1 External Power Supply except for internal DC power supply models 1 set Metal panel mounting clips and screws 2 each 1 User Guide i e this manual continued next page FT14 and FT14H 10Mb Media Converters Installation and User Guide 09 04 Remove the Magnum Media Converter from the shipping container Be sure to keep the shipping container should you need to ship the unit at a later date In the event there are items missing or damaged contact your supplier If you need to return the unit use the original shipping container Refer to Section 5 Troubleshooting for specific return procedures 2 2 Product Description Rugged packaging a selection of extended temperature models choice of AC and DC power types ease of use features and energy efficiency are the primary characteristics of the Magnum 10Mb FT 14 and FT14H Media Converters All models offer
18. available with variety of ratings external AC and internal DC power supplies See Section 1 1 for details _www GarrettCom com s s s s 16 FT14 and FT14H 10Mb Media Converters Installation and User Guide 09 04 Qualified to use for temperature un controlled outdoor application The Magnum FT14H Hardened version of media converter supports the ambient temperature rating up to 40C to 75C for DC options model which qualified for un controlled outdoor application E Compact design mount anywhere Featuring a compact steel case with an external AC power supply Magnum FT 14 Media Converters can be installed in minimal space in rack mount cabinets like MC14 TRAY on table tops or wall mounted E Uplink Switch to eliminate cross over cable while cascading All the Magnum FT 14 series Media Converter featured with Uplink Switch which easily allow the media converter to cascade with other Switch Hub or media converter without using the cross over cable www GarrettCom com s s 17 FT14 and FT14H 10Mb Media Converters Installation and User Guide 09 04 2 4 Applications for FT14 s and hardened FT14H s The primary function of a 10Mb Ethernet Media Converter is to permit two different 1OMb media types to coexist inexpensively within the same network by allowing data to be transmitted and received between different media types Magnum FT 14 series Media Converters are typically used where 1 OBASE T networking
19. blems 3 Make sure that an AC power cord is properly attached to each Magnum FT14 FT14H 10 Mb s Media Converters unit Be certain that each AC power cord is plugged into a functioning electrical outlet Use the PWR LEDs to verify each unit is receiving power ww GarrettCom com jg 48 FT14 and FT14H 10Mb Media Converters Installation and User Guide 09 04 4 If the problem is isolated to a network device other than the Magnum FT14 FT14H 10 Mb s Media Converters product it is recommended that the problem device is replaced with a known good device Verify whether or not the problem is corrected If not go to Step 5 below If the problem is corrected the Magnum FT14 FT14H 10 Mb s Media Converters and its associated cables are functioning properly 5 If the problem continues after completing Step 4 above contact your supplier of the Magnum FT14 FT14H 10 Mb s Media Converters unit or if unknown contact GarrettCom Inc by fax phone or email support garrettcom com for assistance 49 FT14 and FT14H 10Mb Media Converters Installation and User Guide 09 04 5 2 When Calling for Assistance Please be prepared to provide the following information 1 A complete description of the problem including the following points a The nature and duration of the problem b Situations when the problem occurs c The components involved in the problem d Any particular application that when used appears to create the problem
20. e ordered as a separate item e g Model DIN RAIL MC2 It comes with four screws to attach the bracket to the MC unit The rail clip is spring loaded with a pull up latch at the top for easy snap on attachment and removal The Magnum FT14 Models with HR have 24VDC power and have the DIN Rail MC2 bracket included and assembled with the MC unit at the factory A Magnum FT14H is shown alongside the DIN Rail MC2 bracket 3 5 Calculating Overall Segment Distance Important Note Special consideration must be given to maximum cable segment lengths of a Magnum FT 14 and FT14H Media Converter It is recommended that IEEE 802 3 specifications for overall maximum segment distances be adhered to in www GarrettCom com 29 FT14 and FT14H 10Mb Media Converters Installation and User Guide 09 04 order to maintain optimum network performance See also Technical Specs Maximum Standard Ethernet Segment Distances Section 1 1 of this manual When installing the Magnum FT14 series Media Converter it is important to consider the combined overall segment length of both of the attached media types The overall segment length is calculated by adding together the segment lengths on both sides of the Magnum Media Converters Cable segment length on each side of the Media Converter is measured as a percentage of the maximum allowable standard media distance for the given media type The percentages when added together must not exceed
21. e units are powered and proper connections established If the LINK LED is not illuminated change the setting of the up link switch See Section 4 6 for up link switch information If this does not help ensure that the cable is connected properly at both ends and is not defective 3 6 2 Connecting Fiber Optic multi mode single mode half and full duplex The following procedure applies to 1OBASE FL multi mode and single mode applications using the FT14 series Media Converters All have ST type fiber connectors The FT14S single mode differs from the other fiber media converters in terms of the maximum distance allowed The others are used for a multi mode fiber segment lengths of up to 2km The FT14S is used for single mode fiber segments of up to 10km in length The following table continued next page is provided for general information _www GarrettCom com s s se 35 FT14 and FT14H 10Mb Media Converters Installation and User Guide 09 04 Fiber Cable Type cable diameter Max length Wavelength Multi mode fiber 50 125 62 5 125 2km 850 nm Fiber Cable Type cable diameter Max length Wavelength Single mode fiber 2 15 8 60 10km 1300 nm xx yy are the diameters of the core and the core plus cladding respectively The values shown are typical values Procedure for connecting multi mode and single mode fiber cables 1 Before connecting the fiber cable remove the protective dust caps from the tips of the co
22. ees 7 2 0 INTRODUCTION ccccssssssssessessrsensessnsesssensessessnsessesensessesensesseses 8 2 1 Inspecting the Package and the Product ee eee cee cseeereeeeeeeeeee 8 22 Prod ct DESeriptrOn sacisscs tes ielicssienertsrasveubees cxpitaceoucbeaspansvocssutoescuuenueene 9 23 Features and Benefits is sse t2 ccicisesisbidicijnsesavtieai treads eieiei 15 2 4 Applications for FT14 s and hardened FT14H s ou ee eeeeeeeeeeeeeeeeees 18 2 5 Full Half duplex capability 00 eee eeeeeeeeeeceeeeeceaeeeeeseeneeeeaeens 20 2 6 Link Pass through features and Options eeeseeseeeeneeeeeneeeeeeeees 20 3 0 INSTALLATION sseeseseseeecsesosoesesesoeeosesesoeeosoeoesesoecesororoesececoerosoeseeeseee 23 3 1 Locating the Media Converter Unit eee cece eecesecesecesecnseeneeeaes 23 3 2 MC14 TRAY for Rack Mounting of FT14 FT14H Media Converters 25 3 3 MC14 TR PS9 amp MC14 TR PS9X2 for Rack Mount Converters 26 3 4 DIN Rail mounting Option eee eee eeeeeeeeceeecesecesecsseeaeeaes 3 5 Calculating Overall Segment Distance FT14 and FT14H 10Mb Media Converters Installation and User Guide 09 04 3 6 Connecting Ethernet Media 0 eee ee eeeeecseeeecseeeeeeseeeesaeceeeseeneeseenee 34 3 6 1 Connecting Twisted Pair RJ 45 ports eee eeeeeeceeeeeeeeee 34 3 6 2 Connecting Fiber Optic mm sm half and full duplex 35 3 6 3 Power Budget Calcs for Fiber Media Magnum FT 14 series 37 4 0 OPERATION
23. ettCom com jg 42 FT14 and FT14H 10Mb Media Converters Installation and User Guide 09 04 0 2 amp max 48V DC Power Consumption 1 5 watts typical 2 watts maxm 4 3 FT14H DC powered 48VDC 24VDC and 9VDC Installation This section describes the proper connection of the 48VDC leads or 24VDC 9VDC leads to the Direct DC power terminal block on the Magnum FT14H hardened media converter as shown in Figure above The DC terminal block on the Magnum FT 14H is located on the left side of the unit and is equipped with three 3 screw down lead posts The power ww GarrettCom com 43 FT14 and FT14H 10Mb Media Converters Installation and User Guide 09 04 terminals are identified as positive and negative and they are floating inside the unit so that either of the terminal may be grounded by the user if desired The chassis is earth or ground GND The connection procedure is straightforward Simply insert the DC leads to the FT14H s power terminals positive and negative screws The use of Ground GND is optional it connects to the FT14H chassis Ensure that each lead is securely tightened from the top as shown here NOTE Always use a voltmeter to measure the voltage of the incoming power supply and figure out the ve potential lead or ve potential lead The more ve potential lead will connect to the post labeled ve and the rest to the ve The GND can be hoo
24. ge of 36 to 60V DC Power Consumption 1 5 watts typical and 2 watts max for all models Connectors for Media FT14 and FT14H 10Mb Media Converters Installation and User Guide 09 04 RJ 45 Port Modular 8 Pin female with cross over up link switch Fiber Port Fiber optic standard ST type Packaging Enclosure Rugged sheet metal Steel Dimensions Media Converter unit Height x Width x Depth FT14 and FT14H 3 5 in H x 3 0 in W x 1 0 in D 8 9 cm x 7 6 cm x 2 5 cm Weight all FT14 and FT14H mm and sgl mode models 4 6 oz 130g power supply Hd and Hi 3 oz 85g Cooling Method Convection plus the case is used as a heat sink on H models Media Converter LED Indicators LED FT14 FT14S Description PWR unit unit Steady ON when power applied Link per port TP Fiber TP Fiber Steady ON when both attached cable segments are operational at the other end RX Act TP Fiber TP Fiber Indicates port is receiving packets _www GarrettCom com s s lt se 5 FT14 and FT14H 10Mb Media Converters Installation and User Guide 09 04 Metal Mounting clips for panel mounting included DIN Rail mounting option Model DIN RAIL MC2 see Section 3 4 Rack mount option MC14 TRAY see http www garrettcom com mc_tray htm Mean Tine Between Failure MTBF 15 years Telcordia Bellcore Method Agency Approvals and Standard Compliance UL LISTED UL 60950 CUL CE Emissions meet FCC Part 15 Class A NEBS L3
25. ked up at the last When power is applied the green PWR LED will illuminate ww GarrettCom com jg 44 FT14 and FT14H 10Mb Media Converters Installation and User Guide 09 04 4 4 Dual LEDs front panel and side panel Magnum FT14 and FT14H LED Description PWR P Illuminates GREEN to indicate power applied LINK L TP Illuminates GREEN Steady ON when both attached cable segments are operational at the other end LINK will turn off in the event connectivity is lost between the ends of the twisted pair segment or a loss of power occurs in the unit or remote device RX ACT A Blinking GREEN indicates data is being received receive activity Steady On or steady Off indicates no Receive Activity 45 FT14 and FT14H 10Mb Media Converters Installation and User Guide 09 04 4 5 Up Link Cross over Switch The FT14 and FT14H Media Converter is equipped with an Up Link slide switch When set to the UP position X the Media Converter is wired with cross over functionality for direct up RJ45 link to a network hub switch or concentrator up link When set to the DOWN position the Magnum t user device Media Converter is wired for normal twisted pair connection to a user node device Some Ethernet Switch ports may be of either polarity and this feature is most convenient with such switches End view FT14 FT14H 46 FT14 and FT14H 10Mb Media Converters Installation and User Guide 09 04 5 0 TROUBLESH
26. must be greater than the fiber cable s passive Attenuation Attenuation Cable loss LED aging loss Insertion loss safety factor 38 FT14 and FT14H 10Mb Media Converters Installation and User Guide 09 04 4 0 OPERATION This section describes the operation of the Magnum FT14 and FT14H 10Mb Media Converters including power supply requirements up link switch functionality and a description of all LEDs 4 1 Power Requirements Power Supply Types for FT14 and FT14H Magnum FT 14 Media Converters are power efficient and can work with an external AC power supply Magnum FT 14 Media Converters require a nominal 9VDC input version The extended temperature Hd version is used for heavy duty and industrial applications The 9V DC power input has a plug of 2 5mm center ve with 6 ft cord The Magnum FT14 and FT14H media converters are designed to be used with UL listed Class II power supplies Detail info is provided in Technical Specifications Section 1 1 39 FT14 and FT14H 10Mb Media Converters Installation and User Guide 09 04 The FT14H Hardened media converters are designed to provide reliable operation withstand higher temperature environments and provide the direct DC power choices to the user to deploy in uncontrolled temperature environments 9VDC 24VDC 48VDC The Internal 9V DC 8 15V DC has a built in terminal block for ground The 9V DC jack is also present Detail information about
27. n both sides 3 6 3 Power Budget Calculations for Fiber Media Magnum FT14 series Receiver Sensitivity and Transmitter Power are the parameters necessary to compute the power budget To calculate the power budget of different fiber media installations the following equations should be used OPB Optical Power Budget P min Pp min where Pr Transmitter Output Power and Pp Receiver Sensitivity Worst case OPB OPB 1dB for LED aging 1dB for insertion loss Worst case distance Worst case OPB in dB Cable Loss in dB Km where the Cable Loss for 62 5 125 and 50 125um M m is 2 8 dB km and the Cable Loss for 100 140 Multi mode is 3 3 dB km and the Cable Loss for 9 125 Single mode is 0 5 dB km www GarrettCom comn 37 FT14 and FT14H 10Mb Media Converters Installation and User Guide 09 04 The following data has been collected from component manufacturer s HP s and Siemens web sites and catalogs to provide guidance to network designers and installers Fiber Speed Std Wave Cable X mitr R cvr Worst Worst Port Mode km Size Output Sens i Module Std fdx length pm Pr dB P dB dB hdx nm 62 5 125 31 14 5 17 6 FT14 series 10 Mb Multi 2 850 1100 140 31 19 5 5 9 7 all multi py mode 2 50 125 31 9 5 34 4 8 mode FT14S all 10 Mb Single 10 single mode FL mode 5 1300 9 125 30 39 7 14 13 26 Note The worst case OPB of the fiber link
28. nnectors on the media converter Save these dust caps for future use 2 Wipe clean the ends of the dual connectors with a soft cloth or lint free lens tissue dampened in alcohol Make certain the connectors are clean before connecting Note One strand of the duplex fiber optic cable is coded using color bands at regular intervals you must use the color coded strand on the associated ports at each end of the fiber optic segment 3 Connect the Transmit TX port light colored post on the Magnum Media Converter to the Receive RX port of the remote device Begin with the color coded strand of the cable for this first TX to RX connection 4 Connect the Receive RX port dark colored post on the product to the Transmit TX port of the remote device Use the non color coded fiber strand for this _www GarrettCom com se 36 FT14 and FT14H 10Mb Media Converters Installation and User Guide 09 04 5 The LINK LED corresponding to the fiber port on the front of the product will illuminate for standard non Link Pass through models when a proper connection has been established at both ends and when power is ON in the units at each end If LINK is not lit after cable connection the normal cause is improper cable polarity Swap the fiber cables on the product connector to remedy this situation 6 For the Link Pass through model connection is the same except that the LINK indication will not be present unless LINK is made for the cables o
29. nverters Installation and User Guide 09 04 Ambient Relative Humidity 5 to 95 non condensing UL 2043 tested for above the ceiling plenum installation Conformal coating humidity protection option request quote Designed for NEBS compliance including vibration shock and altitude Power Supply These products are intended to be supplied by a Listed Direct Plug In power unit marked Class 2 or a Listed ITE Power Supply marked LPS which has suitably rated output voltage i e 9vdc 12vdc 24vdc 48vdc and suitably rated output current i e 100mA to 500mA When connected to a 48 V centralized dc source these products shall be provided with a Listed 5 A DC fuse in the supply circuit UL listed Class II Power Supply AC DC Adapter 100 240V AC at 50 60Hz for Hd high temp with built in IEC320 connector Power input 9V DC jack is 2 5mm center ve jack with 6ft cord Hd North American models www GarrettCom com s s s lt gt 3 FT14 and FT14H 10Mb Media Converters Installation and User Guide 09 04 100 240V AC at 50 60Hz for high temp with built in IEC320 connector for Hi DC to unit Hi international model r 9V DC 2 5mm jack center ve 6ft cord Power Supply DC Direct built in terminal nepie block for ground The 9V DC jack is also present 9V DC internal range of 7 5 to 15V DC aei 24V DC internal range of 18 to 36V DC 48V DC internal ran
30. oducts will repair products that are under warranty at no charge and will return the warranty repaired units to the sender with shipping charges prepaid see Warranty Information Appendix A for complete details However if the problem or condition causing the return cannot be duplicated by GarrettCom the unit will be returned as No Problem Found www GarrettCom com _ 5s lt 52 FT14 and FT14H 10Mb Media Converters Installation and User Guide 09 04 GarrettCom reserves the right to charge for the testing of non defective units under warranty Testing and repair of product that is not under warranty will result in a customer user charge 53 FT14 and FT14H 10Mb Media Converters Installation and User Guide 09 04 5 4 Shipping and Packaging Information Should you need to ship the unit back to GarrettCom please follow these instructions 1 Package the unit carefully It is recommended that you use the original container if available Units should be wrapped in a bubble wrap plastic sheet or bag for shipping protection You may retain all connectors and this Installation Guide CAUTION Do not pack the unit in Styrofoam popcorn type packing material This material may cause electro static shock damage to the unit 2 Clearly mark the Return Material Authorization RMA number on the outside of the shipping container 3 GarrettCom is not responsible for your return shipping charges 54 F
31. tatement This equipment generates uses and can radiate frequency energy and if not installed and used properly that is in strict accordance with the manufacturer s instructions may cause interference to radio communication It has been tested and found to comply with the limits for a Class A computing device in accordance with the specifications in Subpart J of Part 15 of FCC rules which are designed to provide reasonable protection against such interference when operated in a commercial environment Operation of this equipment in a residential area is likely to cause interference in which case the user at his own expense will be required to take whatever measures may be required to correct the interference ii FT14 and FT14H 10Mb Media Converters Installation and User Guide 09 04 Contacting GarrettCom Inc Please use the mailing address phone and fax numbers and email address listed below GarrettCom Inc 47823 Westinghouse Dr Fremont CA 94539 Phone 510 438 9071 Fax 510 438 9072 Website http www GarrettCom com Email support garrettcom com lil FT14 and FT14H 10Mb Media Converters Installation and User Guide 09 04 TABLE OF CONTENTS Page 1 0 SPECIFICATIONS eseesssesssoesesesosoesesesoeoesosoeseseeecoerosoesesesoeeosoeoeoeeosoesesee 1 1 1 Technical Specifications ssi issssissstsissecsigsiessissessiesiepisbsrs tasses eiss 1 1 2 Summary of models and descriptions ssessseseseeeeseeeseerereerereersesrrerer
32. te the use of cross over cable see sec 4 6 for details Because of their compact size Magnum Media Converters can be Velcro mounted on an office wall or the side of a desk or cabinet Mounting options include panel mounting DIN rail and rack mount tray MC14 TRAY that neatly holds the units and associated power supplies The standard 1 per unit external power supply plugs into a nearby AC wall socket or power strip The FT14H Hardened media converter is also available with _www GarrettCom com 13 FT14 and FT14H 10Mb Media Converters Installation and User Guide 09 04 extended temperature power supply AC DC External Internal to qualify for un controlled and Industrial application Each converter features two full sets of LEDs that convey essential diagnostic and status information at any angle See Section 4 1 and 4 4 for power supply and LED function specifications All of the Magnum FT 14 series Media Converters comply with the IEEE 802 3 10BASE T specification for 10 Mb sec traffic via shielded STP or unshielded twisted pair UTP segments The Link Pass Through feature is especially desirable for use in managed networks and is standard in all FT 14 and FT 14H models Note experience shows that the maximum number of 10Mb Media Converters that can be used in series is three The cumulative signal noise from 4 or more units together in series may cause packet alignment errors 14 FT14 and FT14H 10Mb Media Converters
33. the 9 VDC the 24V DC and the 48V DC is provided in the Technical Specifications Section 1 1 The various models of DC power type and extended ambient temperature power supplies are numerous and your choice needs to be called out on your order 40 FT14 and FT14H 10Mb Media Converters Installation and User Guide 09 04 Note When connected to a 48 V centralized dc source these products are to be installed only in Restricted Access Areas dedicated equipment rooms electrical closets or the like 4 2 Powering the FT14H DC Direct with 12V 24V or 48V DC power input Each Magnum FT 14H is equipped with a Direct DC power supply and have built in screw terminals for secure attachment of the power leads Three models support a range of power input types The three model choices are for use with 9VDC 24VDC or 48VDC power DC power input may be chosen for high availability The extended temperature capability of the DC powered FT14H s can go outdoors rated at 40 C to 75 C If indoors the DC jack 41 FT14 and FT14H 10Mb Media Converters Installation and User Guide 09 04 is also present and optionally can be used with an external AC power supply DC Power Terminals floating GND Terminal for earth or ground wire connection to the FT14H chassis Input Voltage 7 5 15V DC 9V DC 18 26V DC 24V DC 30 60V DC 48V DC Input current 0 8 amp max 9V DC 0 4 amp max 24V DC ww Garr
34. tion segment distance calculation and media connection 3 1 Locating the Media Converter Unit All the FT14 series operate in transparent half and full duplex mode For half duplex traffic the FT14 series work correctly but do not detect or indicate collisions The compact and lightweight design of the Secure attachment of mounting Magnum Media Converter allows it to be clips for wall mounting easily installed in almost any location A 23 FT14 and FT14H 10Mb Media Converters Installation and User Guide 09 04 Velcro strip may be used for mounting the unit on a vertical surface such as a wall or cabinet or for securing the unit on a table top or shelf Alternatively metal mounting clips and screws are included for a rugged and secure mounting in any orientation Installation of the Magnum FT14 and FT14H Media Converters is a simple procedure The installation location is dependent upon the physical layout of the Ethernet network and associated cabling Make sure the unit is installed in a location that is easily accessible to an AC power outlet or power strip and where convection cooling is not inhibited The green Power PWR Led must turn ON when power is applied through the internal DC input 9V 24V or 48V DC or external AC through 9V DC jack 24 FT14 and FT14H 10Mb Media Converters Installation and User Guide 09 04 3 2 MC14 TRAY for Rack Mounting of FT14 and FT14H Media Converters For 19 rack mounting of Magnum
35. uplex RJ 45 NIC in a remote server or to connect one port of a full duplex Switching Hub via fiber to another full duplex 10Mb RJ 45 Switching Hub port All the FT14 series operate in transparent half and full duplex mode For half duplex traffic the FT 14 series work correctly but do not detect or indicate collisions 2 6 Link Pass through features and options The Magnum FT14 Media Converters regular non hardened models come without the Link Pass through feature unless it is specially ordered with the LP model In this regard the FT14 models operate the same as the smaller companion product the Magnum TF14 By comparison the FT14H hardened models come with Link Pass through as a standard feature in order to be used with switches in industrial networks In managed _www GarrettCom com ss 20 FT14 and FT14H 10Mb Media Converters Installation and User Guide 09 04 networks the LINK signal on a managed switch or hub port is used as an indicator that the attached cable segment is installed and operable The network manager using the SNMP agent can troubleshoot the cabling by examining the LINK status on each port This works fine as long as all of the cabling is twisted pair When a twisted pair to fiber media converter is introduced the FT14 regular models of these products not the Magnum FT14H s treat each attached cable segment as a separate entity LEDs on the FT14 Media Converters separately indicate LIN
Download Pdf Manuals
Related Search
Related Contents
MSDS Philips 33621/48/16 Desenhos 3 Step 2011.cdr Road Zeppelin Air Adjustable Seat Kit Instruction - Harley Please read this in conjunction with the Installation Instructions Cette TwoNav [platform][version] Codice 33330 ECG SE-1 SERVICE MANUAL Level 1&2 Copyright © All rights reserved.
Failed to retrieve file