Furuno ED-2200 User's Manual

image

Contents

1. D 4 INTERCONNECTION DIAGRAMS S 1 SCHEMATIC DIAGRAMS 5 2 1 FOREWORD Congratulations on your choice of the FURUNO ED 2200 Remote Depth Indicator We are confident that you will enjoy many years of operation with this fine piece of equipment For over 40 years FURUNO Electric Company has enjoyed an enviable reputation for quality and reliability throughout the world This dedication to excellence is furthered by our extensive global network of agents and dealers ED 2200 is the newest addition to FURUNO s navigational and color video sounders family This new remote depth Indicator repeats the depth indication of Digital Depth Indicator ED 222 or color video sounder It s light weight and compact size make it suitable for any size vessel We would appreciate feedback from you the end user about whether we are achieving our purposes Thank you for considering and purchasing FURUNO equipment FEATURES e Compact cabinet can be mounted on a tabletop or in an instrument panel e Clear 3 digit readouts with 0 1 resolution in meters fathoms or feet e Audible alarm sounds on waters shallower than a preset depth e Depth and alarm data output in FURUNO CIF or 0183 2 DESCRIPTION OF CONTROLS FURUNO REMOTE DEPTH INDICATOR switch rt N 2 DIMMER 0 0 0 u AUTO ALARM control EP910730 027 DISPLAY WINDOW Fig 2 1 Contro
2. Fig 6 2 3 Test terminates showing the settings of J2 and J3 on the MAIN board See Fig 6 3 J3 L LOCAL Alarm REMOTE J2 CIF n n NMEA Fig 6 3 4 Press each key switch The right hand digit indicates the number responding to the key switch as follows Panel key switch test DIM ALARM ALARM Fig 6 4 5 To exit from the test turn off the equipment 12 Depth Indication Display Depth Range Depth Readings Resolution Alarms Depth Alarm Input Output Data CIF only Environmental Conditions Ambient Temperature Humidity Vibration Power Supply amp Power Consumption Color 7 SPECIFICATIONS 3 digit LCD display 0 99 9 100 999 in Feet Meters or Fathoms Automatic digit shift True depth or relative to transducer position subject to depth data from combined equipment 0 1 0 99 9 or 1 100 999 in Feet Meters or Fathoms 1 Buzzer sounds when reading becomes shallower than the depth set by control panel key 0 999 in each unit 2 Receiving the alarm signal from the digital depth indicator ED 222 or the color video sounder alarm sounds and AUTO ALARM is indicated Input Depth and alarm in Furuno CIF or 1 83 data format Output Depth and alarm Furuno CIF or 0183 data format 15to 55 Less than 9596 Less than 1G 750 3000 c p m 11 40VDC less than 5W
3. OPERATOR S MANUAL MODEL ED 2200 FURUNO ELECTRIC CO LTD NISHINOMIYA JAPAN FURUNO ELECTRIC LTD 9 52 Ashihara cho Nishinomiya Japan 662 Telephone 0798 65 2111 Cable FURUNO NISHINOMIYA Telex 5644 325 326 FURUNO J Telefax 0798 65 4200 rights reserved 9 Printed in Japan saco PUB No OME 23331 D ED 2200 Your Local Agent Dealer Initial Version Oct 1991 Version D Feb 7 1996 2 N SAFETY INSTRUCTIONS DANGER WARNING and CAUTION notices appear throughout this manual It is the responsibility of the operator and installer of the equipment to read understand and follow these notices If you have any questions regarding these safety instructions please con tact a FURUNO agent or dealer DANGER A WARNING N CAUTION This notice indicates a potentially hazardous situation which if not avoided will result in death or serious injury This notice indicates a potentially hazardous situation which if not avoided could result in death or serious injury This notice indicates apotentially hazardous situation which if not avoided could result in minor or moderate injury or property damage 1 SAFETY INFORMATION FOR THE OPERATOR A NWARNING Do not open the cover of the equipment This equipment uses high voltage electricity which can shock bum or cau
4. Control Panel N3 0 not changed Cabinet 2 5 GY 5 1 5 13 7 SPECIFICATIONS STANDARD SET ACCESSORIES FP12 00700 No Name Outline Type Qty Code Number 179 1 Bracket 12 003 3301 0 1 100 156 220 2 Rubber Washer 12 003 3302 0 100 156 230 3 Knob Bolt JB 12 003 3303 0 100 156 240 Tapping Screw 6x20 SUS 304 000 800 414 Flush Mount Plate 22 003 2001 1 100 085 621 Tapping Screw 4x16 SUS304 000 802 955 14 7 SPECIFICATIONS INSTALLATION MATERIALS 12 01000 Outline Code Number Power Cable 2250019 2 Assembly VV0 75x2C 3m 000 109 000 _ 2250021 3 NMEA Cable EA SA 7 0 16 4C 000 109 517 5 SPARE PARTS SP12 00700 Outline 20 re O Tes Spare Parts Box 000 831 610 OPTIONAL SUPPLY ee FURUNO 4 97 Rit 7x FIXING HOLES D RECOMMENDED SERVICE SPACE E 54 E MATERIAL DWG REMARKS 512 GB p 8 REMOTE DEPTH INDICATOR CHECKED TABLE TOP MOUNT BRAWN C NS C2333 G02 B TOMITA FURUNO ELECTRIC LTD ED 2200 FURUNO p p ARRE r A RECOMMENDED SERVICE SPACE FIXING HOLES D CUTTING DIMENSION 4 Exi zd 18 MATERIAL QTY OW G NO REMARKS 83A _ REMOTE DEPTH INDICATOR ED 2200 FLU
5. 0 15813 JHL 03 Ld30Xd WAHL OF 43114440165 SHIYN Sid HS 0301AO03d Sv Sy 521035 G 3LOANNOO 38 0022 03 i ROE e 223002 YIMTIOUG 2 03 igt AYVSSAIOINNN S 0022 03 OL SNIVW S id HS 30 NO LOINNOS 2022 01 40 PREF 01 O3i103NNOO 51 022 NAHM gt 17213 err ErHOOcc a3 6100568 Jano 39 01 WH NO 1d0 01 SOLVvOlUN er 1200522 YAGNNOS 30102 0022 43 PILE HLA f Woe St 1 100 SNIVA S dIHS 5 9 5 48 9 K pee fpe E 0 01 Ui 1 22 6 RAS Et i 8 2 0 i5 e s ASD 5 ADS 3 134 2 5 2 2 2 01 01 1 0 H aub 12 1 JuO1VOIQNI _ SOLVOLIONI er iZ0DSZZ PEED Hld3g NO 130 2930 310W33 _ 310w3s _ 301701041 0022 03 EALE 0022 03 Kld30 7 119148 222 03 me PBN RL ONTA 0226139 5 Li uh m 45 KOK OM XX S 02P6140 t 1 et 2250011 OSDR CHASSIS Cl C2 2 Pur
6. If ED 2200 is And setting of J3 on Th 4 combined with MAIN board is en alarm sounds When the seabed goes shallower than the preset depth ED 222 or Color Video Sounder LOCAL When the ED 222 out puts the alarm signal REMOTE When the color video sounder outputs the bottom alarm signal Color Video Sounder The depth indication differs by the setting of the draft control of ED 222 or color video sounder If the draft is not adjusted Depth is obtained from the ship s hull transducer adjusted Depth is obtained from the sea surface The indication AUTO ALARM appears on the window 4 OPERATING PROCEDURE Turn the ED 2200 on The depth appears in the display window Adjust the brilliance by the DIM key the control knob the Dimmer Unit if necessary BH Set the alarm zone by the ALARM 4 or Key The alarm sounds when the ship enters waters shallower than the preset alarm zone This alarm zone setting functions in LOCAL operation mode only Refer to page 10 5 INSTALLATION Mounting Site The ED 2200 may be mounted in the following methods a Tabletop Mount b Overhead Mount c Flush Mount Necessary Considerations Adry and well ventilated place Vibration free place A place shaded from direct sunlight A place not exposed to rain or watersplash Mounting
7. 7 03 0 1 0018 8 43225 AZU4 REMOTE DEPTH 0 2400 INDICATOR 2333 05 FURUNO ELECTRIC CO LTD
8. setting 1 Set the alarm setting depth to 0 to disable the alarm The indication ALARM goes off i 2 There are two alarm operation modes LOCAL and REMOTE See page 10 The alarm zone setting can be made in only the LOCAL operation mode Alarm OFF Press ACK key to stop the audible alarm appears The alarm restores itself automatically when the depth goes deeper than the preset depth and again goes shallower than the preset depth aa ee Audible o mmm m Alarm i 1 key pressed Alarm zone set here Fig 2 3 Alarm Operation 2 DESCRIPTION OF CONTROLS Remarks for setting Alarm Zone in LOCAL independent operation mode DRAFT ADJUSTED of digital depth indicator ED 222 ED 2200 Alarm Zone Setting Set the depth from the ship s hull transducer Set the depth from the sea surface Remember that the alarm zone differs with the DRAFT setting on ED 222 3 READING THE DISPLAY WINDOW H BD AUTO ALARM 910730 O2T Fig 3 1 Display Window Depth The seabed depth Depth appears in increments of 0 1 above 100 in 1 unit steps Depth Unit To change the depth unit see page 9 The indication ALARM appears when the alarm zone is set ALARM When the alarm condition is violated the buzzer sounds The condition to activate the alarm is
9. the equipment to prevent electrical shock and mutual interference Ungrounded equipment can give off or receive electro magnetic interference or cause electrical shock Confirm that the power supply voltage is compatible with the voltage rating of the equipment Connection to the wrong power supply can cause fire or equipment damage The voltage rating appears on the label at the rear of the equipment 5 1 FOREWORD 1 Features 1 2 DESCRIPTION OF 16 2 Power Switch 2 Dimmer 2 Alarm Control 2 3 READING THE DISPLAY WINDOW 5 4 OPERATING PROCEDURE 6 5 INSTALLATION 2 7 Mounting Site 7 Mounting Method 7 Cable Connection 8 Power Supply 8 6 CHECK AFTER INSTALLATION 9 Changing Depth Unit 9 Changing Specification 9 Display Window Test LCD 12 7 SPECIFICATIONS 13 OUTLINE DRAWINGS
10. Method Tabletop Overh 1 Use the hanger a template to mark two fixing holes Inner pair or outer one pair on the table overhead or bulkhead Fix the hanger by two self tapping screws Set the remote display unit to the hanger and tighten the knob bolts Do not forget to place the rubber washer between the unit and the hanger Q3 Mount 1 Make a hole in the mounting location as shown in Fig 5 1 A P 4 173mm Fig 5 1 h 5 INSTALLATION 2 Fit the two pieces of flush mount plates into the slots on the display unit Fig 5 2 3 Fix the unit by four screws prepared locally Cable Connection Cable connections to the ED 2200 are made at the connectors located at the rear of the unit Refer to the interconnection diagram on page S 1 Power Supply This unit is designed to operate at any voltage between 11 and 40 Vdc The ED 2200 can also be operated by 5V supplied from the ED 222 Refer to page S 1 6 CHECK AFTER INSTALLATION For technicians Changing Depth Unit 1 Turn on the equipment while pressing ACK key The unit currently selected appears on the screen 2 To change the depth unit press ALARM key until desired unit appears M meter __________ FT feet _____ FA fathom 1 NOTE Pressing ALARM key changes the unit in reverse order 3 To restore norm
11. SH MOUNT 2333 601 FURUNO ELECTRIC LTD FURUNO Rays 7 2 __ ___ __ NNNM NNNM ITEM NAME MATERIAL QTY DWG NO REMARKS A OUTLINE OF DIMMER BOX 2217 28 41 A amp T THIRD ANGLE PROJECTION TITLE LSU D AY FLUSH MOUNT 27 8577 a amp weed 2 2333 G07 B FURUNO ELECTRIC CO LTD FURUNO 46 S _ DETAIL OF NAME PLATE 2 79 HOLE FOR M6 SET BOLTS ES QN t N x 7 sus acar 70001400001 LR I e Ay 5 gt zZ TA O7 BoD lt gt 3 b 20 TS X a NAME MATERIAL DWG NO REMARKS 4 AYO THIRO ANGLE PROJECTION ome SE SS ERE zu UMP L2 7 MF22L2A OUTLINE OF DIMMER BOX CHECKED ye Ei BULKHEAD MOUNT 73 41182 8 C2333 G06 B FURUNO ELECTRIC CO LTD 117 09 021819313 ONNYNG 8 E00 20 ON Wvdovid NOI LO3NNOO3 31N1 0062 03 31121 5 AG ANd NO OL AQr iad QuvoH 2819420 NO ZS HOLIMS HO WANL SNIVA S dlHS 250 192420 4 Y G COMMING
12. al operation turn off and on the equipment The indication of the depth unit depends on the supplied depth data from the combined equipment If ED 2200 is And selection of Then the depth unit on combined with data format is the window is Unit selected by the NMEA ED 2200 steps explained above ED 222 or ED 2200 CIF 0 2200 tl selected by CIF or NMEA Color video sounder Color video sounder Unit selected by color video sounder Jfthere is a unit other than M FT or FA the depth without unit appears 6 CHECK AFTER INSTALLATION Changing The specification can be changed by reselecting the jumper block settings Specification on the MAIN and SUB boards The specifications which can be changed are 1 Communication data format 2 Alarm operation mode 3 Power supply line ON OFF control method 4 Power ON OFF control Refer to the table below Data Format MAIN Board Alarm operates by alarm zone setting of 02 6139 Alarm Operation 0 2200 Mode REMOTE Alarm operates by alarm data from the ED 222 color video sounder The power is supplied from the ship s mains Power Supply 45 power is supplied and controlled from the ED 222 The function of PWR and OFF SUB key is disabled The power switch of the ED 2200 turns the equipment on and off Power ON OFF Control The external breaker switch turns the REMOTE equipment on and off The f
13. l Panel G POWER Switch The POWER switch turns the equipment on and off Press PWR to turn on the equipment Press PWR and OFF simultaneously to turn off the equipment 1 external breaker switch can turn on off the ED 2200 2 The digital depth indicator ED 222 can turn on off the ED 2200 if 5V line of ED 222 is connected to ED 2200 In this case the PWR and OFF switches are disabled Change jumper block setting on the SUB board to select 1 or 2 See page 10 2 DIMMER Control The DIM key adjusts the brilliance of the keyboard and display in the following sequence 2 Bright di d2 _ ___ 46 if the DIMMER unit is connected to the ED 2200 DIM key function is disabled 3 ALARM Control The alarm sounds when the seabed goes shallower than the specified depth shallow alarm mode In waters where the depth is known to dramatically and suddenly rise without warning it may be a good idea to turn on the depth alarm 2 DESCRIPTION CONTROLS Alarm zone setting 1 Press ALARM or to set the alarm zone The depth window indicates the alarm setting depth The window restores the depth in dication about five seconds after terminating the setting The alarm sounds if the ship enters waters shallower than the preset depth FURURO DEPTH ITO Alarm setting depth Alarm Zone Alarm Fig 2 2 Alarm zone
14. se death Only qualified personnel should work inside the equipment Do not dissasemble or modify the equipment Fire electrical shock or serious injury can result Immediately turn off the power at the ship s mains switchboard if water or foreign object falls into the equipment or the equipment is emitting smoke or fire Continued use of the equipment can cause fire electrical shock or serious injury N CAUTION Do not place liquid filled containers on the top of the equipment Fire or electrical shock can result if a liquid spills into the equipment Do not place heater near the equipment Heat can melt the power cord which can result in fire or electrical shock Do not operate the unit with wet hands Electrical shock can result Use the correct fuse Use of the wrong fuse can cause fire or equipment damage SAFETY INFORMATION FOR THE INSTALLER A NWARNING Only qualified personnel should work inside the equipment This equipment uses high voltage electricity which can shock burn or cause death Turn off the power at the ship s mains switchboard before beginning the installation Post a warning sign near the switchboard to ensure that the power will not be applied while the equipment is being installed Serious injury or death can result if the power is not turned off or is applied while the equipment is being installed A CAUTION Ground
15. unction of PWR and OFF key is disabled shows the factory setting The setting for data format on each board should be the same 48 setting takes effect if J5 is set to SHIP S MAINS Idle current flows even when the power is turned off ff you want to cut the power to the ED 2200 completely turn off the breaker switch Remarks of J3 settings Alarm operation mode 1 When LOCAL is selected refer to the operation instructions on pages 3 and 4 2 When connecting with the digital depth indicator ED 222 the REMOTE mode is recommendable to emit alarm from both units simultaneously 10 6 CHECK AFTER INSTALLATION Ship s Mains J8 POWER ON OFF 5 6 CIF NMEA CIF NMEA Local Remote POWER SUPPLY NMEA ED 222 02 6140 9 MAIN Board 02P8139 J2 CIF NMEA NMEA Remote Local J3 Alarm Fig 6 1 Location of Jumper Blocks 11 6 CHECK AFTER INSTALLATION Display Window Test LCD Turn on the equipment while pressing DIM key to start the display LCD window test The display is checked in the following sequence 1 Ail indications blink twice Fig 6 2 shows all indications on the window 2 Each indication lights sequentially from top left to right All numeral segments display from 0 to 9 in succession KEEL ANCH SHALLOW DEEP AUTO ALARM AT