Contents
1. PM PRO unit has been subjected to physical abuse has been operated without a proper safety ground or has been modified in any way without written authorization from Furman Furman s liability under this warranty is limited to repair or replace ment of the defective unit Furman will not be responsible for incidental or consequential damages result ing from the use or misuse of its products Some states do not allow the exclusion of incidental or consequential damages so the above limitations may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from state to state Warranty claims should be accompanied by a copy of the original purchase invoice showing the purchase date if a Warranty Registration Card was mailed in at the time of purchase this is not necessary Before returning any equipment for repair please read the important information on service below Service Before returning any equipment for repair please be sure that it is adequately packed and cushioned against damage in shipment and that it is insured We sug gest that you save the original packaging and use it to ship the product for servic ing Also please enclose a note giving your name address phone number and a description of the problem NOTE All equipment being returned for repair must have a Return Authoriza tion RA Number To get an RA Number please call the Furman Service Depart ment 707
2. the input voltage is marginally high Power to the PM PRO s outlets will remain on unless the incoming voltage rises above the Extreme Voltage Shutdown high cutoff 3 If none of the LEDs on the voltmeter are lit and the Extreme Voltage LED indicator is flashing continuously then the PM PRO has shut down power to its switched outlets because the input voltage is in a range considered extreme The PM PRO s voltmeter has a basic accuracy of plus or minus two volts and extreme cold or heat may cause an additional one volt of error four volts and two volts for the PM PRO E Please note that the voltage reading is advisory only The PM PRO does not compensate for high or low line voltage If you frequently move your rack to different locations derive power from generators use long extension cords travel internationally or are in an area prone to brownouts you may benefit from the use of one of Furman s AC Line Voltage Regulators LED AMMETER This three color 10 LED ammeter will give you a reliable indica tion of current draw even for highly nonlinear loads like amplifiers and switching power supplies It reads AC current from 0 to 20 amps in two amp steps PM PRO E 0 to 16 amps in 1 6 amp steps When using audio power amps with the PM PRO it is normal for the current draw to fluctuate considerably increasing on musical peaks and decreasing at quiet times To avoid tripping the PM PRO s circuit breaker adjust your levels so that the
3. T1 C AJ gt MODELS PM PRO PM PRO E Owner s Manual 3 9844 1998 FURMAN SOUND INC 960112 1407 PM PRO POWER CONDITIONER MONITOR PM PRO PM PRO E SPECIFICATIONS Note Where different PM PRO E specs are in parentheses Current rating 20 Amps 2400 Watts at 120 VAC 16 Amps 3600 Watts at 230 VAC Input Voltage Range 0 to 280 VAC without damage Meter Accuracy Voltmeter 2 4 VAC Ammeter 2 amps calibrated with trimpot adjustments Spike Protection Modes Line to neutral neutral to ground line to ground Clamping Voltage all modes TVSS rating 400V peak L N L G N G tested to UL 1449 TVSS rating 400V peak L N 680V peak L G N G Response time 1 nanosecond Maximum surge current 11 000 amps 8 x 20mS pulse Maximum spike energy 550 joules total Noise attenuation Differential mode Greater than 40 dB Common mode greater than 60 dB both 1 to 200 MHz Dimensions 1 75 4 45 cm H x 19 48 25 cm W x 8 25 cm D Weight 6 Ibs 2 7 kg Construction Steel chassis zinc chromate plating brushed and black anodized aluminum front panel glass epoxy printed circuit boards Power consumption 32 Watts Safety Information PM Pro UL listed CUL listed PM PRO E CE Options G Suffix PM PRO only provides super spec isolated ground 120V outlets for special applications Please consult factory before ordering to determine suitability in your application The Furman PM PRO is manufactured in the
4. highest peaks do not exceed the rated current NOTE The Voltmeter Ammeter and status LEDs stay on even when the power switch is off This feature allows you to check voltage and current before power ing up your equipment Both of these LED meters are designed for continuous ongoing use They consume little power just a few cents worth a month much like a clock UNSWITCHED OUTLET This outlet provides conditioned power at all times when the PM PRO is plugged in and operating under normal conditions CIRCUIT BREAKER ON OFF SWITCH This appears to be an ordinary toggle switch but in fact is a precision magnetic circuit breaker Because its operation is magnetic not thermal it is much more accurate in its tripping current yet it PM PRO POWER CONDITIONER MONITOR will not be tripped falsely by the transient high inrush currents often encoun tered when turning on large reactive loads like power amps Its trip point is unaffected by ambient temperature The breaker switch controls power to the eight switched rear panel outlets but does not affect the voltmeter the amme ter or the status LEDs If it trips reduce the load on the PM PRO and push it back to the ON position Note The PM PRO E s circuit breaker is not mag netic Voltmeter Displays The PM PRO informs you of voltage problems at a glance The following chart summarizes how the PM PRO s voltmeter responds to input voltages from extremely low to extremely high 90 100 11
5. its proper ventilation For example the PM PRO must not be placed on a rug bed sofa or similar surface which impedes airflow across the chassis 4 Do not place the PM PRO near heat sources such as radiators heat registers stoves or other appliances that produce heat 5 The PM PRO should only be connected to a 120 VAC 60 Hz 20 amp grounded electrical outlet Outlets wired for 20 amps may be identified by the T shaped socket opening that accepts the perpen dicular blades of the PM PRO s power plug If you don t have a 20 amp outlet available have one in stalled by a qualified electrician Do not defeat the ground or polarization of the power plug 6 Route the power cord and other cables so that they are not likely to be walked on tripped over or stressed Pay particular attention to condition of cords and PM PRO POWER CONDITIONER MONITOR cables at plugs and the point where they exit from the PM PRO To prevent risk of fire or injury damaged cords and cables should be replaced immediately 7 Clean the PM PRO with a damp cloth only Do not use solvents or abrasive cleaners Never pour any liquid on or into the PM PRO 8 When left unused for a long period of time the power cord of the PM PRO should be unplugged from the outlet 9 The PM PRO should be serviced by qualified service personnel when a The power supply cord or the plug has been frayed kinked or cut b Objects have fallen or liquid has spilled into the u
6. 0 120 128 AC VOLTS Mains Voltage Status PM PRO Voltmeter Reading Outlets Below 80V Extreme Shutdown Meter off Extreme Voltage LED flashes OFF 80 90 Low Marginal The LED beneath the 90V mark flashes ON 90 104 Low Meter Reads in Low Red ON 106 108 Medium Low Meter Reads in Low Yellow ON 110 120 Normal Meter Reads in Green ON 122 124 Medium High Meter Reads in High Yellow ON 126 128 High Meter Reads in High Red ON 130 140 High Marginal All Meter LEDs Flash ON Above 140 Extreme Shutdown Meter off Extreme Voltage LED Flashes OFF For PM PRO E double all indicated voltages Power Status LEDs PROTECTION EXTREME OK VOLTAGE GROUND L a J e O e FLASHES WHEN SHUT DOWN Symptom Possible Cause Action Needed Symptom Possible Cause Action Needed Symptom Possible Cause Action Needed Symptom Possible Cause Action Needed PM PRO POWER CONDITIONER MONITOR PROTECTION OK Indicator not lit Protection devices are damaged Factory Service Ground OK Indicator not lit No building ground bad outlet Locate good ground run ground wire Flashing voltmeter display Input voltage is marginally high or marginally low Correct line voltage Consider installing a Furman voltage regulator EXTREME VOLTAGE Indicator is flashing Input voltage is extremely high or extremely low causing power to the PM PRO s outlets to be shut down Correct line voltage Consider installing a Furman vol
7. 763 1010 ext 40 Please display your RA Number prominently on the front of all packages PM PRO POWER CONDITIONER MONITOR 11 PM PRO POWER CONDITIONER MONITOR Other Furman Products Power Conditioning amp Distribution PL 8 PL PLUS Power Conditioner amp Light Module 15A PL PRO Power Conditioner amp Light Module 20A PL TUNER Power Conditioner Instrument Tuner 15A PLH 15 Power and Light Center 15A PM 8 Power Conditioner Monitor 15A PS 8 PS 8R Power Conditioner Sequencer 15A PS PRO Power Conditioner Sequencer 20A PowerLink Remote AC Power Sequence Controller PowerPort Remote AC Power Controller MiniPort 15 Power Relay 15A MiniPort 20 Power Relay 20A MiniPort 15Q Power Relay for Quad Box Mount 15A MiniPort 20Q Power Relay for Quad Box Mount 20A RS 1 System Control Panel Maintained Switching RS 2 System Control Panel Momentary Switching AR 1215 AC Line Voltage Regulator 15A 120V AR 2306 AC Line Voltage Regulator 6A 230V AR 1220 AC Line Voltage Regulator 20A 120 100V AR 1230 AC Line Voltage Regulator 30A 120 100V AR 2330 AC Line Voltage Regulator 30A 220 230 240V AR 2330D AC Line Voltage Regulator 30A 24 230 220V N America Use AR PRO AC Line Voltage Regulator 30A 120V Worldwide Use BP 1000 On Line Uninterruptible Power Supply 1KVA ACD 100 Power Distro 100A ASD 120 Sequenced Power Distro 120A T 1210 Isolation Transformer Balanced AC Power 10A T 1220 Isolation Transformer Balanced AC
8. Power 20A T 1230 Isolation Transformer Balanced AC Power 30A PlugLock Locking Outlet Strip PlugLock PRO Locking Outlet Strips Vertical Mount WartStrap PlugLock WartStrap Wall Wart Retention Kit Power Conditioning amp Distribution 3 Reissue arametric Equalizer Instrument Preamp PQ 4 Parametric Equalizer 4 band Q 151 Q 152 Dual 15 Band Graphic Equalizer Q 301 Q 302 30 Band Graphic Equalizer Q 602 Dual 30 Band Graphic Equalizer Q 541 Quad 5 band Stereo Graphic EQ PUNCH 10 Bass Enhancement System X 312 12 dB Crossover X 324 2 Way 3 Way 24 dB Crossover X 424 3 Way 4 5 Way 24 dB Crossover X 524 4 Way 24 dB Crossover C 132 Compressor Limiter LC 6 Stereo Compressor Gate QN 44 Quad Noise Gate SP 20A Stereo Half rack Power Amp 20W per channel HA 6A Headphone Monitor Amp HR 2 Headphone Passive Remote Box HDS 6 Headphone Distribution System HR 6 Personal Headphone Mixer for use with HDS 6 PB 48 48 Point Patch Bay with TRS Connectors PB 48D 48 Point Patch Bay with TRS and D Sub Connectors Full range of patch cords also available MM 3 Three Input Mic Mixer MM 4A 4 x 1 Rack Mount Mixer MM 8A 4 x 2 Rack Mount Mixer DJM 6 DJ Production Mixer DJM 8 DJ Production Mixer SM 3 Stereo Mixer with Ducking IP 8 Iso Patch Isolated Patch Bay 8 Channel IP 2 IP 2B Iso Patch Dual Isolator 2 Channel VU 40 System Monitor Power VU Meter SC 1 2 Security Covers
9. U S A n m BH ma m Hm NA m E H RM 5 uz a A BH v 7n C FA Furman Sound Inc 1997 South McDowell Bivd Petaluma California 94954 6919 Phone 707 763 1010 Fax 707 763 1310 Web http www furmansound com E Mail info furmansound com PM PRO POWER CONDITIONER MONITOR Safety Information To obtain best results from your Furman PM PRO please be sure to read this manual carefully before using it WARNING To reduce the risk of electrical shock do not expose this equip ment to rain or moisture Dangerous high voltages are present inside the enclosure Do not remove the covers There are no user serviceable parts inside Refer servicina to qualified personnel onlv The lightning flash with arrowhead symbol within an equi lateral triangle is intended to alert the user to the presence of uninsulated dangerous voltage within the product s enclo sure that may be of sufficient magnitude to constitute a risk of electric shock Important Safety Instructions Please read prior to installation 1 Please read and observe all of the safety and operating instructions before the PM PRO is operated Retain these instructions for future reference 2 The PM PRO should not be used near water for example near a bathtub washbowl kitchen sink laundry tub in a wet basement near a swimming pool etc 3 The PM PRO should be situated so that its location and position do not interfere with
10. for use as an on off switch The rear panel provides eight switched AC outlets to power up all your equipment These outlets are spaced widely enough to accommodate up to four bulky plug mounted power supplies wall warts The heavy duty 12 AWG power cord is 10 feet 2 4 m in length for extra reach and durability on stages and other high traffic areas PM PRO Compared to PM PRO E The PM PRO is intended for use with 120 VAC power and is rated at 20 amps the PM PRO E is for 230 VAC power and rated at 16 amps Outlets on the PM PRO E are IEC 320 types The GROUND OK feature is not available on the PM PRO E Other differences concern the reading of the voltmeter and ammeter and other specifications which are described on page 8 and on the rear cover PM PRO POWER CONDITIONER MONITOR Front Panel Controls PROTECTION EXTREME LINE VOLTAGE OK VOLTAGE GROUND 90 100 110 120 128 20 AMP POWER OK i i i CONDITIONER MONITOR e e e 00000600606060000000000060 FLASHES MODEL PM PRO ASHE AC VOLTS SN FLASHING DISPLAY INDICATES OUT OF RANGE PROTECTION OK This LED is normally on when the power to the PM PRO s outlets is switched on It monitors the integrity of the protection devices and reports if the protection is compromised If an extremely large spike is encoun tered that exceeds the PM PRO s capacity the main group of input protectors will blow an internal fuse causing the indicator to go out If this LED is not lit when the po
11. he mains power is below the low cutoff voltage and has caused the PM PRO to remove power from its outlets the PM PRO will not restore power to the outlets until the mains voltage rises to more than 10V above the cutoff Similarly if the mains power is above the high cutoff and has caused a shut down the PM PRO will not restore power to the outlets until the mains voltage falls more than 10V below the cutoff The reason for this is to prevent the power oscillating on and off in marginal conditions LED VOLTMETER This three color 20 LED bargraph is an accurate self check ing AC voltmeter that continually measures normal voltages The meter reads from 90 to 128 volts in 2 volt steps PM Pro E 180 to 256 volts in 4 volt steps The normal range voltages are indicated in green with moderate and extremely high or low voltages in yellow and red respectively see chart on PM PRO POWER CONDITIONER MONITOR 7 CURRENT 20 AMPS 2 8 14 20 C2 I l Il Il i rem 0000000060 FRSA AC AMPS O diem rre E E E UNSWITCHED OUTLET POWER C2 PROTECTIVE SHUTDOWN MAY OCCUR page 8 The voltmeter provides three special flashing patterns to indicate ab normal power conditions 1 If only the single leftmost LED flashes the input voltage is marginally low Power to the PM PRO s outlets will remain on unless the incoming voltage falls below the Extreme Voltage Shutdown low cutoff 2 If all of the LEDs on the voltmeter flash
12. nit c The PM PRO has been exposed to rain or other moisture d The PM PRO does not appear to operate normally or exhibits a marked change in performance e The PM PRO has been dropped or the enclosure damaged 10 The PM PRO requires that a safety ground be present for proper operation Any attempt to operate the PM PRO without a safety ground is considered im proper operation and could invalidate the warranty 11 There are no user serviceable parts in the PM PRO Refer servicing to qualified service personnel only PM PRO POWER CONDITIONER MONITOR Introduction Thank you for your purchase of a Furman PM PRO or PM PRO E Power Con ditioner Monitor and congratulations on your choice For simplicity in this manual the designation PM PRO refers to either the PM PRO or the PM PRO E unless a specific distinction is made A summary of the differences between the two models appears at the bottom of this page The PM PRO is one of Furman s top of the line PRO Series power conditioners It is designed to provide maximum protection from the types of hazards faced by delicate analog and digital pro audio and video equipment Your PM PRO provides the most complete and comprehensive protection from power line related transient voltages noise and wiring faults available It combines a high voltage surge and transient suppressor with an RFI EMI interference filter The fast acting suppression circuit responds in less than a nanosecond clam
13. ping transient voltages to safe levels The filter works to prevent noise from fluorescent lights certain dimmers radio transmitters and similar sources of electronic pollu tion from contaminating the AC line and from there leaking into sensitive audio video or computer circuits What sets the Furman Pro Series apart from other conditioners is the quantity quality and configuration of its suppression devices These include MOV s gas discharge tubes fast blow fuses and high voltage inductors and capacitors This unique combination can safely absorb and dissipate large spikes from nearby light ning strikes and other sources up to 11 000 amps across any wiring mode hot neutral hot ground or neutral ground as well as highly attenuate audible high frequency noise Precise high inrush magnetic circuit breakers avoid the false trip ping often encountered with large reactive loads like power amps The PM PRO front panel provides a three color 20 LED line voltage meter a true RMS reading 10 LED AC ammeter and three status LEDs to indicate abnor mal power conditions The PM PRO will even keep itself from turning on or shut down under extreme conditions if the voltage is below 80 volts or above 140 volts below 160 volts or above 280 volts for PM PRO E The front panel also provides an unswitched outlet clean filtered power is provided at the unswitched outlet too and a 20 amp 16 amp for PM PRO E magnetic circuit breaker rated
14. tage regulator Effects of Lightning Lightning is a natural phenomenon of overwhelming force that represents the most difficult circumstance faced by a power protection product The degree of protection a PM PRO can offer depends on the intensity of the strike If lightning strikes a distant power line and causes a relatively small disturbance to reach your location the spike suppressors in the PM PRO will absorb the excess voltage in visibly and harmlessly However if lightning strikes the actual building where the PM PRO is installed or somewhere very nearby some damage may be unavoid able due to the extremely high voltage and current present If this does occur most likely damage will be limited to the PM PRO itself and will affect only certain spike suppression components called varistors or MOV s In this suicide mode the PM PRO may sustain minor damage but generally will protect all equipment plugged into it from much more serious and costly damage as long as that equipment is properly grounded Proper grounding requires the use of three prong AC cords and that the building s outlets are actually grounded to earth as specified by the National Electric Code Any PM PRO known to have taken a direct lightning hit should be checked by a qualified technician or the Furman factory to determine whether the MOV s need replacement If the PROTECTION OK indicator is not lit there is definitely some damage Some spike suppression capabili
15. ty may still be available by MOV Bank 2 but there is no guarantee of this For optimum protection you should not rely exclusively on the PM PRO to pro tect against a direct lightning hit The first line of defense against lightning should be a lightning arrestor installed on your building s electrical service entrance If your building does not have one contact your local power company or a contractor to have one installed PM PRO POWER CONDITIONER MONITOR Limited Warranty Important Note To be sure of obtaining full protection under the terms of the Three Year Limited Warranty in case your ownership documents are lost please fill out and return the Warranty Registration Card immediately Please verify that the serial number shown on the Warranty Card matches the serial number on your unit The Furman PM PRO is warranted against failures due to defective parts or faulty workmanship for a period of three years after delivery to the original owner During this period Furman will make any necessary repairs without charge for parts or labor Shipping charges to the factory or repair station must be prepaid by the owner return shipping charges via UPS Ground will be paid by Furman This warranty applies only to the original owner and is not transferable Also it does not apply to repairs done other than by the Furman factory or Authorized Repair Stations This warranty shall be cancellable by Furman at its sole discretion if the
16. wer switch is on full protection is not functioning Spike protection may still exist but will have a reduced capacity to absorb current If this LED is not lit please contact the Furman Service Department GROUND OK This LED is normally on when the power to the PM PRO s outlets is switched on It monitors the integrity of the grounding and reports if the ground ing is compromised It lights if a reasonably good safety ground exists If this LED is not lit when the power is on the PM PRO is not properly grounded Unplug the PM PRO and correct the ground Not available on PM PRO E EXTREME VOLTAGE SHUTDOWN This LED status indicator is normally off It monitors a hazard unfortunately common in the entertainment industry wiring faults for example accidental connection to 220V where 120V is expected The PM PRO senses voltages that are so high or low that operation would be impossible and shuts the power down before damage can occur For the PM PRO the cutoff voltages are under 80V or over 140V for the PM PRO E under 160V or over 280V Upon initially applying power to the PM PRO this indicator will be lit if the input voltage is below the low cutoff or above the high cutoff and power will not be applied to the PM PRO s outlets If the unit has been operat ing within an acceptable input voltage and then that voltage goes out of the ac ceptable range the PM PRO will shut power to the outlet and this LED will begin flashing NOTE If t