Fujitsu RX600 User's Manual
Contents
1. After power failure The server automatically reboots following a power failure depending on the settings in the BIOS or in iRMC S2 Power button override The system can be switched off by pressing and holding down the On Off button for approximately 4 5 seconds 76 Operating Manual RX600 S5 Starting up and operation Switching the server on and off CAUTION There is a risk that data may be lost iRMC S2 iRMC S2 offers various options for switching the server on and off e g via the Power On Off page of the iRMC S2 Web interface CAUTION when turning the power off Windows Server 2008 or Windows Server 2003 The operation of the power switch can be specified as Do Nothing Ask me what to do only for Windows Server 2003 Stand by Hibernate and Shutdown depending on the OS settings The default is Shutdown On this server functions corresponding to Stand by and Hibernate are supported as BIOS and hardware functions However some drivers and software installed in the server do not support these functions For this reason functions corresponding to Stand by and Hibernate are unavailable on this server When the operating mode is set to Stand by or Hibernate the system may operate improperly or hard disk data may be corrupted For details about operating mode settings refer to the manual supplied with the OS RX600 S5 Operating Manual 77 Configuring the server S
2. 112 8 1 4 4 Installing a hot plug expansion card 113 8 1 5 Hot plugmemory boards 2 2 pe eh eee ee 115 8 1 5 1 Identifying the defective memory 116 8 1 5 2 Removing the memory board in question 117 8 1 5 3 Removing a defective memory module T17 8 1 5 4 Installing a new memory module a oaoa aa 119 8 1 5 5 Reinstalling the memory board in question 119 8 1 5 6 Adding a memory board noaoae 120 8 2 Non hot plug components asaan aeaa 121 8 2 1 Identifying the defective CSS component 122 8 2 2 Replacing a non hot plug expansioncard 122 8 2 2 1 Removing a non hot plug expansion card 122 8 2 2 2 Installing a non hot plug expansion card 125 8 2 3 Replacing SFP transceiver modules 126 8 2 3 1 Removing an SFP transceiver module 126 RX600 S5 Operating Manual Contents 8 2 3 2 Installing SFP transceiver modules 129 8 3 Opening Closing the server 22 000005 134 8 3 1 Opening the server 2 0000 eee eee 134 8 3 2 Closing ihe SENET s s sitaat neer a we Hw 136 9 Appendix server specification n aoaaa aaau 137 NGE crag Gd wee ake Se eae ae Bae ee ek a tk oe Be 143 Operating Manual RX600 S5 1 Preface The scalable PRIMERGY RX600 S5 server is an Intel based rack server for critical company scenarios e g as database management system for medium
3. cO Operating manual English FUJITSU PRIMERGY RX600 S5 Server Operating Manual January 2011 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual Your feedback helps us optimize our documentation to suit your individual needs Feel free to send us your comments by e mail to E Mail manuals ts fujitsu com Certified documentation according to DIN EN ISO 9001 2008 To ensure a consistently high quality standard and user friendliness this documentation was created to meet the regulations of a quality management system which complies with the requirements of the standard DIN EN ISO 9001 2008 cognitas Gesellschaft f r Technik Dokumentation mbH www cognitas de Copyright and Trademarks Copyright 2011 Fujitsu Technology Solutions GmbH All rights reserved Delivery subject to availability right of technical modifications reserved All hardware and software names used are trademarks of their respective manufacturers The contents of this manual may be revised without prior notice Fujitsu assumes no liability for damages to third party copyrights or other rights arising from the use of any information in this manual No part of this manual may be reproduced in any form without the prior written permission of Fujitsu Microsoft Windows Windows Server and Hyper V are trademarks or registered trademarks of Microsoft Corporation i
4. Index system error 67 70 information additional 13 installation connect to mains voltage 55 connecting devices 53 connecting monitor 54 connectors 53 installation in rack 43 SFP transceiver module 129 installation overview 25 installing in 3rd party rack 51 DataCenter rack 46 PRIMECENTER rack 46 installing in the rack notes 38 Integrated Mirroring Enhanced 78 integrated Remote Management Controller 18 iIRMC S2 18 L labels 40 LAN connectors 54 laser information 33 light emitting diode LED 33 lithium battery 31 Low Voltage Directive 35 low voltage directive 23 M magnetic tape drive 15 mains voltage 55 management LAN connector 18 meaning of the symbols 22 MegaRAID 78 memory hot spare 16 memory module inserting 119 removing 117 memory scrubbing 16 monitor connecting 54 display drifts 87 no display 87 monitor port 54 N NMI button 64 65 noise level 24 notational conventions 22 6 On Off button 65 on off button 64 operating system installing 80 operation configuring the server 78 server switch on off 75 optical drive indicator 63 overload 19 P packaging 39 42 PCI slots 15 dummy module 112 expansion cards replacing 107 PDA 17 19 power supply unit cable clamp 60 power supply units 16 power on indicator 64 66 does not light 85 prefailure detection and analysis 17 PRIMECENTER rack installing server 46 requirements 43 product name 42 64 property protection 83
5. 4 2 2 Installation in PRIMECENTER DataCenter rack For installation ina PRIMECENTER DataCenter rack the following parts are required Support bracket One support system on the left and one on the right M5 centering fixtures screws with integrated plugwashers i The descriptions and figures in this section refer to the current support system For other support systems you will find the appropriate description in the packaging of the rack mounting kit For information on mounting of the rails in the 19 inch standard rack for the Japanese market please refer to the Rack mount guide General information regarding server installation in the rack is included in the technical manual for the appropriate rack For information on mounting of the server in the 19 inch standard rack for the Japanese market please refer to the Rack mount guide 46 Operating Manual RX600 S5 Hardware installation Rack installation removal of server Fitting the support bracket When mounting the left support system in the corresponding rack the supplied support bracket must first be mounted flush with the underside of the device on the rear left support upright Figure 3 Fitting the support bracket gt Position the support bracket at the corresponding height on the rear left support upright place knob in the corresponding hole 1 and secure it with the two supplied M5 centering fixtures 2 RX60
6. Installation Manager user s guide on ServerView Suite DVD 2 under Industry Standard Servers Software ServerView Suite Server Installation and Deployment RX600 S5 Operating Manual 25 Overview of the installation steps Configuration information can also be found in section Configuring the server and installing the operating system with the ServerView Installation Manager on page 79 Local configuration and installation with or without ServerStart see section Configuring the server and installing the operating system with the ServerView Installation Manager on page 79 or section Configuring the server and installing the operating system without the ServerView Installation Manager on page 80 You will find more information on installing the server remotely or i locally in the ServerView Suite Installation Manager user s guide on the ServerView Suite DVD 2 under Industry Standard Servers Software ServerView Suite Server Installation and Deployment 26 Operating Manual RX600 S5 3 Important information In this chapter you will find essential information regarding safety when working on your server 3 1 Safety instructions The following safety instructions are also provided in the manual Safety Notes and Regulations or Z LOQ TFB This device meets the relevant safety regulations for IT equipment If you have any questions about whether you can install the server in the in
7. Starting up and operation on page 63 and the ServerView Suite Local Service Concept LSC manual on the ServerView Suite DVD 2 proceed as follows gt Exit all applications and shut down the server properly see section Switching the server on and off on page 75 gt Pull all power connectors out of the power outlets gt Remove the server from the rack see section Rack installation removal of server on page 43 and place the server ona table for example RX600 S5 Operating Manual 121 Non hot plug components CSS components 8 2 1 Identifying the defective CSS component gt Open the server see Opening Closing the server on page 134 gt Press the Indicate CSS button on the system board see Technical Manual for the system board D2870 on the ServerView Suite DVD 2 The PRIMERGY Diagnostic LED of the defective CSS component lights up orange thereby indicating which CSS component on the system board must be replaced see Technical Manual for details 8 2 2 Replacing a non hot plug expansion card 8 2 2 1 Removing a non hot plug expansion card gt f necessary remove all cables from the expansion card gt Open the expansion card lock by lifting it up see pos 2 in figure 28 on page 109 The expansion card is now mechanically unlocked gt Hold the removal tool by the green handle and pull it out of the PCI slot together with the expansion card see pos 3 in figure 28 on page 109 i Do
8. You can loosen the cable clamp by opening the small locking lever 60 Operating Manual RX600 S5 Hardware installation Notes on connecting disconnecting cables 4 5 Notes on connecting disconnecting cables CAUTION Always read the documentation supplied with the device you wish to connect Never connect or disconnect cables during a thunderstorm Never pull on a cable when disconnecting it Always take hold of the cable by the plug Follow the sequence described below to connect or disconnect external devices to or from the server Be sure to wait for 10 seconds or more after shutdown before turning the server on Connecting cables gt Turn off all power and equipment switches gt Disconnect all power plugs from the properly grounded power outlets gt Connect all cables to the server and peripherals gt Plug all data communication cables into the utility sockets gt Plug all power cords into the properly grounded power outlets Disconnecting cables gt Turn off all power and equipment switches gt Disconnect all power plugs from the properly grounded power outlets gt Unplug all data communication cables from the utility sockets gt Disconnect the relevant cables from the server and all the peripherals For connecting or disconnecting LAN cables the server need not to be powered off To avoid loss of data teaming function has to be enabled RX600 S5 Operating Manual 61 Notes on connecting disconnec
9. or large sized databases or as a consolidation basis to run an immensely large number of different applications using virtualization technologies Thanks to its highly developed hardware and software components the server offers a high level of data security and availability These include hot plug HDD modules hot plug system fans and also hot plug power supply units the Server Management ServerView Suite Prefailure Detection and Analysis PDA and Automatic Server Reconfiguration and Restart ASR amp R Security functions in the BIOS Setup and on the system board protect the data on the server against manipulation Additional security is provided by the lockable rack door The server occupies 4 height units HU in the rack 1 1 Concept and target groups for this manual This operating manual describes how to install set up and operate your server This operating manual is intended for those responsible for installing the hardware and ensuring that the system runs smoothly It contains all the information you need to put your PRIMERGY RX600 S5 into operation To understand the various expansion options you will need to be familiar with the fields of hardware and data transmission and you will require a basic knowledge of the underlying operating system RX600 S5 Operating Manual 11 Documentation overview Preface 1 2 Documentation overview More information on your PRIMERGY RX600 S5 can be found in the following docum
10. 100 68 Operating Manual RX600 S5 Starting up and operation Control elements and indicators 5 1 2 Rear of server 5 1 2 1 Global Error indicator and CSS indicator i a rO amp f mf pe a Figure 15 Global Error indicator and CSS indicator 1 CSS indicator yellow Lights up yellow if a prefailure event was detected for a CSS component that you can fix yourself for reasons of precaution with the CSS concept Flashes yellow if an error was detected that you can fix yourself with the CSS concept Does not light up when the system is OK If the event is still acute after a power failure the indicator is activated after the restart The indicator also lights up in standby mode For more information on the CSS concept see Customer Self Service CSS on page 14 RX600 S5 Operating Manual 69 Control elements and indicators Starting up and operation 2 Global Error indicator orange Lights up orange if a prefailure event has been detected that requires precautionary service intervention Flashes orange if an error was detected that requires service intervention Does not light up if there is no critical event If the event is still acute after a power failure the indicator is activated after the restart The indicator also lights up in standby mode You can find more details on the indicated errors in
11. 3 5 4 6 1 6 2 7 1 7 2 7 3 7 4 Connecting the powercord 2 20 60 Notes on connecting disconnecting cables 61 Starting up and operation 0208280 0s 63 Control elements and indicators 55 63 Fonta SENE 22426 9S hee Ss ebay LES be ewes 63 Control elements oe raseri bee aiena e 65 Indicators onthe control panel 66 Indicators on the accessible drives components 67 Indicators on the hot plug HDD modules 68 Reardi Senei 2 2 Sse OS LSS eee eh oe be SS 69 Global Error indicator and CSS indicator 69 ID indicator and button cso 6 Ka we RE Hee Ew Os 71 Indicators on the connector panel LAN indicators 72 Indicators on the hot plug power supply units 73 Switching the server on and off 2 2 5585 75 Configuring the server 2 2 25 ee ee eee eee 78 Configuring the SAS SATA RAID controller card 78 Configuring the server and installing the operating system with the ServerView Installation Manager 79 Configuring the server and installing the operating system without the ServerView Installation Manager 80 Cleaning the server 2 2 02 2 eee eee eee 81 Property and data protection 05282005 83 Mechanical access protection 0 50005 83 BIOS Setup security functions 2 83 Troubleshooting and tips 0 0508225 0 85 Power on indicator rem
12. 5 Management LAN connector 2 x USB connector gt Connect the data cables to the server and peripherals Connect keyboard and mouse via USB There are no separate PS 2 connectors for them Connecting the monitor gt Plug the data cable for the monitor into the video connector on the server Alternatively the video connector at the front or the rear of the server can be used gt Connect the power cord of the monitor to a grounded mains outlet of the in house mains and or into the mains socket strip of the rack 54 Operating Manual RX600 S5 Hardware installation Connecting the server to the mains 4 4 Connecting the server to the mains CAUTION The server is automatically set to a mains voltage in the range 100 127 V 200 240 V You may only operate the server if its rated voltage range corresponds to the local mains voltage 4 4 1 Installation requirements The power subsystem consists of Power supply modules PSU A power distribution board PDB The power supply subsystem can support up to 4 PSUs which all connect to the PDB The total system is rated 100 127 V 200 240 V 50 60 Hz 28 14 A The minimum system configuration requires installation of at least two PSUs The PSU is considered hot swappable see Hot plug power supply units on page 93 The system can be configured to support True AC redundancy or non AC redundancy True AC redundancy is recommended for
13. CSS components Figure 46 Unlatching the locking bail gt Carefully unlatch and fold down the locking bail on the SFP transceiver module Figure 47 Inserting the SFP transreiver gt Insert and slide the SFP transceiver module into the socket connector as far as it will go If only one slot is equipped with a SFP transceiver module use the primary right connector as shown 130 Operating Manual RX600 S5 CSS components Non hot plug components Figure 48 Latching the locking bail gt Carefully fold up and latch the locking bail RX600 S5 Operating Manual 131 Non hot plug components CSS components Figure 49 Attaching the protective optical port plug gt If the SFP transceiver module is not immediately connected to an LC connector attach the protective optical port plug to the transceiver optical bores 132 Operating Manual RX600 S5 CSS components Non hot plug components Figure 50 Installing the secondary SFP transceiver module gt f applicable install the secondary SFP transceiver module accordingly RX600 S5 Operating Manual 133 Opening Closing the server CSS components 8 3 Opening Closing the server CAUTION The actions described in this section may only be performed by personnel with the appropriate technical training The device can be seriously damaged if it is opened without auth
14. Manual 37 Notes on installing the server in the rack Important information 3 6 Notes on installing the server in the rack CAUTION For safety reasons at least two people are required to install the server in the rack because of its weight and size For the Japanese market please refer to RE LNEBEKUZO th Eta Never lift the server into the rack using the handles on the front panel When connecting and disconnecting cables observe the relevant instructions in the Important Information chapter of the technical manual for the corresponding rack The technical manual is supplied with the corresponding rack When installing the rack make sure that the anti tilt mechanism is correctly fitted For safety reasons no more than one unit may be removed from the rack at any one time during installation and maintenance work If several units are simultaneously removed from the rack there is a risk that the rack could tip over The rack must be connected to the power supply by an authorized specialist electrician If the server is integrated into an installation that draws power from an industrial power supply network with an IEC309 type connector the power supply s fuse protection must comply with the requirements for non industrial power supply networks for the type A connector 38 Operating Manual RX600 S5 Important information Environmental protection 3 7 Environmental protection Environmentall
15. PSU indicators 73 redundance 93 R rack installing server 43 removing server 43 requirements 43 RX600 S5 Operating Manual 145 Index RAID controller 15 17 RAID controller is not configured for this drive 89 RAID level 17 recycling devices 40 regulations and standards 23 Remote Storage 18 removal SFP transceiver module 126 replace fans 97 memory boards 115 PSUs 93 SFP transceiver modules 126 requirements 3rd party rack 44 DataCenter rack 43 PRIMECENTER rack 43 reset button 64 65 return of devices 40 routing cables 49 S safety precautions 27 safety standards 23 SAS Riser Board RAID controller 15 SAS riser card 17 SAS SATA RAID controller configuring 78 saving energy 39 screen error message 89 flickering 87 remains blank 86 shows flickering stripes 87 serial connector COM1 54 serial number 42 64 server accessible drives 15 availability 16 configuration 20 78 connectors 53 cooling 16 data protection 83 data security 16 dimensions 24 electrical data 22 error correction 85 features 11 14 installation 41 noise level 24 open 134 operation 63 productname 42 property protection 83 routing cables 49 safety precautions 27 serialnumber 42 ServerStart 78 starting up 63 switches itself off error 86 switching on off 75 technical data 22 transport 37 troubleshooting 85 unpacking 42 voltage range 16 server management 19 ServerStart 78 ServerView Installation Manager 20 79 ServerVie
16. as well as premature wear of the disks by observing the following suggestions Only insert disks in the drive when needed and remove them after use Store the disks in suitable sleeves Protect the disks from exposure to heat and direct sunlight Laser information The optical drive complies with IEC 60825 1 laser class 1 CAUTION The optical drive contains a light emitting diode LED which under certain circumstances produces a laser beam stronger than laser class 1 Looking directly at this beam is dangerous Never remove parts of the optical drive casing RX600 S5 Operating Manual 33 Safety instructions Important information Modules with Electrostatic Sensitive Devices Modules with electrostatic sensitive devices are identified by the following sticker A When you handle components fitted with ESDs you must always observe the following points Figure 1 ESD label e Switch off the system and remove the power plugs from the power outlets before installing or removing components with ESDs e You must always discharge static build up e g by touching a grounded object before working with such components e Any devices or tools that are used must be free of electrostatic charge e Wear a suitable grounding cable that connects you to the external chassis of the system unit e Always hold components with ESDs at the edges or at the points marked green touch points e Do no
17. gt Swivel the levers in an upright position and lift the memory board up and out using its levers simultaneously 2 8 1 5 3 Removing a defective memory module CAUTION e Please note the equipping rules in the Technical Manual for the system board D2870 e To avoid burning your fingers wait for a sufficient period of time before installing or removing memory modules e Do not install unauthorized third party memory modules Doing so may cause electric shock a fire or failures e Donot insert and remove memory modules repeatedly Doing so may cause failures e Ifthe memory module has not been correctly inserted it may cause a fire Insert the memory module with attention to its direction RX600 S5 Operating Manual 117 Hot plug components CSS components e f a memory module is installed and you pull the lever strongly outwards the memory module pops up Doing so may cause a device failure e Please observe the safety information in chapter Important information on page 27 To guarantee that all memory modules in the relevant storage mode have i identical characteristics you must always replace 4 memory modules on each memory board The only exception is memory boards running in spare mode or in independent mode these only require 2 memory modules to be replaced For more information on the individual storage modes see the Technical Manual System Board D2870 for PRIMERGY RX600 S5 Figu
18. manual on the ServerView Suite DVD 2 Your server is equipped with a ServerView Local Service Display which enables you to identify the type of component affected by the error directly on the server for more information see the ServerView Suite Local Service Concept LSC manual on the ServerView Suite DVD 2 In addition CSS errors are displayed in the ServerView Operations Manager the server management software from Fujitsu In the event of errors the ServerView Operations Manager refers you directly to the affected component and its order information in the Illustrated Spares catalog of the server in question This feature is not available for the Japanese market 14 Operating Manual RX600 S5 Preface Features System board The features of the system board are described in the technical manual for the system board D2870 for the hardware and in the BIOS Setup manual for the firmware Hot plug PCI slots The server has ten PCI Express slots where two of them are hot plug slots These hot plug PCI Express slots allow installation and removal of boards during operation when the operating system supports this function for further details see section Hot plug expansion cards on page 107 Hard disk drives The server can be equipped with up to 8 SAS SATA HDD modules Each HDD module can accommodate a SAS SATA hard disk drive with a 2 5 inch format The modules are connected to the SAS SATA backplane wirelessly Th
19. move it in the direction of the arrow 2 and out of the housing i Keep the memory air baffle for future use gt Install the equipped memory board into the respective slot Memory boards that you insert must suit the fitting rules and the appropriate configuration See the Technical Manual for details gt Press the ATTN button gt Wait until the ATTN LED is turned off gt Close the server as described in Closing the server on page 136 120 Operating Manual RX600 S5 CSS components Non hot plug components 8 2 Non hot plug components CAUTION The actions described in this section may only be performed by personnel with the appropriate technical training The device can be seriously damaged if it is opened without authorization or if repairs are attempted by untrained personnel The circuit boards and soldered parts of internal options are exposed and can be damaged by static electricity Before handling them first touch a metal part on the server to discharge static electricity from your body Do not touch the circuitry on boards and soldered parts Hold the metallic areas or the edge of the circuit boards Touch only the specified part of the printed circuit board Failure to do so may cause injury It may also cause failures Please observe the safety information in chapter Important information on page 27 If a defective non hot plug component is detected for more information see chapter
20. power outlet s gt Wait afew seconds before you plug it them into the grounded power outlet s again gt Switch on your server RX600 S5 Operating Manual 85 Server switches itself off Troubleshooting and tips 7 2 Server switches itself off Server Management has detected an error gt Check the error list of System Event Log in ServerView Operations Manager or in the iRMC S2 web interface and attempt to eliminate the error 7 3 Screen remains blank Monitor is switched off gt Switch on your monitor Screen has gone blank gt Press any key on the keyboard or gt Deactivate screen saver Enter the appropriate password Brightness control is set to dark gt Set the brightness control on the monitor to light For detailed information refer to the operating manual supplied with your monitor Power cable or monitor cable not connected gt Switch off the monitor and the server gt Check whether the power cable is properly connected to the monitor and to the grounded power outlet gt Check whether the monitor cable is properly connected to the server and monitor if it is plugged in with a connector If a separate graphics card is installed in the server then the monitor cable must be connected to the graphics card gt Switch on the monitor and the server 86 Operating Manual RX600 S5 Troubleshooting and tips Flickering stripes on monitor screen 7 4 Flickering stripes on monitor
21. protection interference suppression Only install system expansions that satisfy the requirements and rules governing safety and electromagnetic compatibility and those relating to telecommunication terminals If you install other expansions they may damage the system or violate the safety regulations Information on which system expansions are approved for installation can be obtained from our customer service center or your sales outlet The components marked with a warning notice e g lightning symbol may only be opened removed or exchanged by authorized qualified personnel Exception CSS components can be replaced The warranty is void if the server is damaged during installation or replacement of system expansions Only set screen resolutions and refresh rates that are specified in the operating manual for the monitor Otherwise you may damage your monitor If you are in any doubt contact your sales outlet or customer service center Before installing removing internal options to from the server turn off the server all peripheral devices and any other connected devices Also unplug all power cords from the outlet Failure to do so can cause electric shock Do not damage or modify internal cables or devices Doing so may cause a device failure fire or electric shock Devices inside the server remain hot after shutdown Wait for a while after shutdown before installing or removing internal options The circuit board
22. repairs and reduces service costs This leads to a reduction in the total cost of ownership and an excellent return on investment for the remote management solution The administrator can access all system information and information from the sensors such as fan speeds or voltages via the IRMC S2 s Web interface see section iIRMC S2 with integrated management LAN connector on page 18 You can also start the text based or graphic console bypass Advanced Video Redirection AVR and connect virtual drives as remote storage The features of the IRMC S2 Advanced Video Redirection and Remote Storage are available as an option More information about the iIRMC S2 can be found in the IRMC S2 integrated Remote Management Controller user s guide on the ServerView Suite DVD 2 under Industry Standard Servers Software ServerView Suite Out Of Band Management RX600 S5 Operating Manual 21 Notational conventions Preface 1 4 Notational conventions The following notational conventions are used in this manual Text in italics indicates commands or menu items Quotation marks indicate names of chapters and terms that are being emphasized gt describes activities that must be performed in the order shown CAUTION pay particular attention to texts marked with this symbol Failure to observe this warning may endanger your life destroy the system or lead to the loss of data i indicates ad
23. servers installation depth 714 785 mm without restrictions gt Refer to the manual from the rack manufacturer for details of the mechanical installation and the climatic conditions CAUTION When installing in 3rd party racks it must be ensured that an air flow from the front to the back of the rack is guaranteed gt Fit the required original parts support bracket or cable management system RX600 S5 Operating Manual 51 Rack installation removal of server Hardware installation Under certain circumstances you will not be able to use some of the parts from the rack installation kit supplied you will need to use Original 3rd party rack parts instead Racks with installation depth of 735 mm The lengths of the telescopic rails do not need to be adjusted with respect to each other for the installation in rack systems with 735 mm installation depth gt Secure the support systems as described in section Installing the support systems on page 48 gt Mount the server see Inserting the server on page 50 and route the cables as described in the original manual of the rack CAUTION Ensure that the safety lock has been inserted before the server is inserted see figure 4 on page 48 Racks with installation depth smaller greater than 735 mm The support systems can be used for installation depths of 714 785 mm The spring element of the support system is used to adjust the length as required gt S
24. the System Event Log SEL on the ServerView Local Service Display in the ServerView Operations Manager or via the iRMC S2 s Web interface 70 Operating Manual RX600 S5 Starting up and operation Control elements and indicators 5 1 2 2 1D indicator and button a 51 LOLOL A jai T Figure 16 ID indicator 1 ID indicator blue Lights up blue when the system has been selected by pressing the ID button To deactivate press the ID button again The ID indicator can also be activated via the ServerView Operations Manager and the iRMC S2 Web interface and its status reported to the ServerView Operations Manager and the iRMC S2 2 ID button RX600 S5 Operating Manual 71 Control elements and indicators Starting up and operation 5 1 2 3 Indicators on the connector panel LAN indicators N E th 2 amp 1 me ict 11 a io oe Y ET A3 Figure 17 LAN indicators 1 LAN speed Steady yellow signal in the event of a LAN transfer rate system LAN of 1 Gbit s shared Pat Steady green signal in the event of a LAN transfer rate of 100 Mbit s Remains dark in the event of a LAN transfer rate of 10 Mbit s 2 LAN Steady green signal when a LAN connection exists link transfer system LAN shared LAN Flashes green when LAN transfer takes place Remains dark when no LAN connection exists 3 LAN speed Steady green
25. the removal tool gt Remove the engaging hooks 2 and keep them in a safe place gt To insert a new expansion card continue with section Installing a hot plug expansion card on page 113 CAUTION If you remove an expansion card and do not insert a replacement you will have to use a dummy module for better cooling to comply with applicable EMC regulations regulations on electromagnetic compatibility and to protect against fire Ensure that the dummy module engages correctly in the slot RX600 S5 Operating Manual 111 Hot plug components CSS components 8 1 4 3 Removing a dummy module If a slot does not contain an expansion card it is occupied by a dummy module This is a retaining plate with an attached removal tool Before inserting an additional hot plug expansion card you will first have to remove the dummy module from its slot gt Open the server see Opening Closing the server on page 134 gt Remove the dummy module in the same way as a PCI board see figure 29 on page 110 Removing the retaining plate from the removal tool CAUTION When removing the retraining plate from the removal tool pay particular attention to the engaging hooks that fasten it to the removal tool Never lift the engaging hooks by more than approx 1 mm in other words only as far until the retaining plate is released Otherwise you could damage the engaging hooks 1T IEE ii lf tii li i i A i F
26. used in a hot environment The customer shall bear the cost of replacing replaceable components which have exceeded their operating life Note that these are only guidelines and do not constitute a guarantee of trouble free operation during the maintenance support period High safety use This product has been designed and manufactured for general uses such as general office use personal use domestic use and normal industrial use It has not been designed or manufactured for uses which demand an extremely high level of safety and carry a direct and serious risk to life or body if such safety cannot be ensured RX600 S5 Operating Manual These uses include control of nuclear reactions in nuclear power plants automatic airplane flight control air traffic control traffic control in mass transport systems medical devices for life support and missile guidance control in weapons systems hereafter high safety use Customers should not use this product for high safety use unless measures are in place for ensuring the level of safety demanded of such use Please consult the sales staff of Fujitsu if intending to use this product for high safety use Measures against momentary voltage drop This product may be affected by a momentary voltage drop in the power supply caused by lightning To prevent a momentary voltage drop use of an AC uninterruptible power supply is recommended This notice follows the guidelines of Voltage Dip Imm
27. 0 S5 Operating Manual 47 Rack installation removal of server Hardware installation Installing the support systems Figure 4 Fit the left support system in the PRIMECENTER DataCenter rack gt Position the left hand support system in the support bracket insert retaining bolts see 1 gt Clamp the left hand support system 2 between the front left support upright and the support bracket by pressing the support system together positioning it on the front support upright and releasing it again The support system automatically adjusts to the rack depth The support system no longer has to be fixed to the front support upright because the easy lock engages and ensures a firm fit 48 Operating Manual RX600 S5 Hardware installation Rack installation removal of server gt Insert 3 the safety lock into the easy lock snap fit CAUTION Ensure that the safety lock has been inserted before the server is inserted gt Repeat the above steps for the right hand support system with the front and rear right support uprights gt Fitthe PRIMECENTER DataCenter rack cable management as described in the Technical Manual for the corresponding rack gl L O O 0O E O E C Bg C L LJ LI L Figure 5 Position of the cage nuts gt Fit the cage nuts for securing the server in the corresponding catches on the right and left support uprights gt Insert the server see Inser
28. 5 Operating Manual 141 Appendix server specification 142 Operating Manual RX600 S5 Index 3rd party rack installing in 51 requirements 44 A accessible drives DVD 15 67 magnetic tape 15 acclimatization time 41 101 Advanced Video Redirection 18 ambient conditions 24 ASR amp R 17 automatic server reconfiguration amp restart 17 AVR 18 B batteries 31 BIOS security functions 83 update 20 Cc cables connecting 61 disconnecting 61 CE marking 23 35 chipkill 16 Class A Compliance Statement 36 cleaning keyboard 81 monitor 81 mouse 81 server 81 connecting devices 53 monitor 54 connecting cables 61 connection panel 53 connectors LAN 54 serialCOM1 54 USB 54 63 video 63 consumables 39 controls ID button 64 on off button 64 reset button 64 cooling 16 correcting faults 85 CSS indicator 64 66 69 D data protection 83 data security 16 DataCenter rack installing server 46 requirements 43 date incorrect 88 delivery note 42 dimensions 24 disconnecting cables 61 disposal devices 40 drive dead 88 defective 89 drive module acclimatization time 101 dummy module expansion card PCI slots 112 dummy module HDD module 103 106 111 124 DVD drive 15 indicator 67 E ECC 16 EDC 16 electrical data 22 RX600 S5 Operating Manual 143 Index electromagnetic compatibility 23 35 H electrostatic sensitive devices hard disk activity indic
29. Mercury Pb Lead RX600 S5 Operating Manual 31 Safety instructions Important information Working with CDs DVDs BDs and optical drives When working with devices with optical drives these instructions must be followed CAUTION Only use CDs DVDs BDs that are in perfect condition in order to prevent data loss equipment damage and injury Check each CD DVD BD for damage cracks breakages etc before inserting it in the drive Note that any additional labels applied may change the mechanical properties of a CD DVD BD and cause imbalance Damaged and imbalanced CDs DVDs BDs can break at high drive speeds data loss Under certain circumstances sharp CD DVD BD fragments can pierce the cover of the optical drive equipment damage and can fly out of the device danger of injury particularly to uncovered body parts such as the face or neck High humidity and airborne dust levels are to be avoided Electric shocks and or server failures may be caused by liquids such as water or metallic items such as paper clips entering a drive Shocks and vibrations are also to be avoided Do not insert any objects other than the specified CDs DVDs BDs Do not pull on press hard or otherwise handle the CD DVD BD tray roughly Do not disassemble the optical drive Before use clean the optical disk tray using a soft dry cloth As a precaution remove disks from the optical drive when the drive is not to be used for a long
30. PCI hot plug software or by pressing the light pipe switch see pos 1 in figure 28 on page 109 The light pipe switch flashes green The slot is in the enable sequence Wait until the light pipe switch is constantly green The slot is now powered on i If the light pipe switch continues to flash an error has occurred Remove the expansion card and repeat the procedure as described above Close the server see Opening Closing the server on page 134 114 Operating Manual RX600 S5 CSS components Hot plug components 8 1 5 Hot plug memory boards CAUTION e The actions described in this section may only be performed by personnel with the appropriate technical training The device can be seriously damaged if it is opened without authorization or if repairs are attempted by untrained personnel e Please observe the safety information in chapter Important information on page 27 The system board has space for up to eight memory boards each of which can be equipped with up to eight memory modules The slots for the main memory are suitable for 2 GB 4 GB 8 GB and 16 GB DDR3 1066 1333 MHz memory modules This allows a maximum memory capacity of 1024 GB with availability of 16 GB memory modules A possible memory module fault is reported by the CSS indicator lighting up on the front and rear of the server or displayed on the ServerView Local Service Display for more information about the behavior of the Local Se
31. a on the drive for your own security e Rough handling of hard disk units can damage the stored data To cope with any unexpected problems always back up important data When backing up data to another hard disk drive you should make backups on a file or partition basis e Be careful not to hit the hard disk unit or bring it into contact with metallic objects e Use the device on a shock and vibration free surface 100 Operating Manual RX600 S5 CSS components Hot plug components e Donotuse the unit in extremely hot or cold locations or locations with extreme temperature changes e Never attempt to disassemble the hard disk unit Handling drives and HDD SSD modules Drives incorporated in the HDD SSD modules are highly sensitive electromagnetic devices and must be handled with great care Incorrect handling can cause partial or total failure of the drives These failures can result in data errors and to a loss of data or to total corruption of the drive Observe the following rules to prevent such problems occurring e Only store and transport HDD SSD modules within the limits stipulated in the specification e When transporting HDD SSD modules even over short distances always use the original packaging ESD label e Never expose HDD SSD modules to a temperature shock Avoid the formation of condensation inside and on the outside of the drive CAUTION The HDD SSD module must be acclimatized in its operating environ
32. ains unlit 5 85 Server switches itself off 02 0522005 86 Screen remains blank 2 2 0 002 ee eee eee 86 Flickering stripes on monitor screen 87 Operating Manual RX600 S5 Contents 7 5 No screen display or display drifts 87 7 6 Incorrect date and time 0 0082 eee 88 7 7 Drives reported as dead when starting system 88 7 8 Added drive reported as defective 5 89 7 9 Error message onscreen 220 2 ee eee 89 8 CSS components 2 6242 0 d 66600 ee Ye Oe Home amp 91 8 1 Hot plug components 2 0 0202 eee eee 93 8 1 1 Hot plug power supply units 0 93 8 151 Replacing a hot plug power supply unit 94 8 1 1 2 Adding a hot plug power supply unit aoaaa aa 95 8 1 2 PCN Taas ce kad oe ae a B aa he a a 97 8 1 2 1 Replacing a defective fan aoaaa aaa 98 8 1 2 2 Adding new fans 2 pda aitbaar ma dadada 99 8 1 3 Hotplug HDD modules s airera ee iiti ee di 100 8 1 3 1 HDD SSD module and dummy module 102 8 1 3 2 Removing installing the dummy module 103 8 1 3 3 Installing the HDD module 2 104 8 1 3 4 Removing the HDD module 105 8 1 4 Hot plug expansion cards 2200 107 8 1 4 1 Identifying the defective CSS component 109 8 1 4 2 Removing a hot plug expansion card 109 8 1 4 3 Removing a dummy module
33. al 23 Technical data Preface Dimensions Weight Rack W x D x H 482 6 mm Bezel 444 8 mm Body x 770 0 mm x 176 0 mm Mounting depth rack 728mm Height unit rack 4U 19 rackmount Yes Mounting cable depth rack 100 mm 1000 mm rack recommended Weight min 32 kg max 46 kg actual weight may vary depending on configuration Rack integration kit rack integration kit as option Rack integration kit is standard for the japanese market Ventilation clearance At least 200 mm on the front and rear Ambient conditions Environment class 3K2 Environment class 2K2 EN 60721 IEC 721 Part 3 3 EN 60721 IEC 721 Part 3 2 Temperature Operation 3K2 Transport 2K2 10 C 35 C 25 C 60 C Humidity 10 85 non condensing Condensation during operation must be avoided Noise level Sound power level Lwag ISO 9296 lt 6 2 B standby lt 6 6 B operation Sound pressure level at bystander position LpAm lt 46 dB A standby ISO 9296 at lt 23 C lt 51 dB A operation 24 Operating Manual RX600 S5 2 Overview of the installation steps This chapter contains an overview of the steps necessary to install your server Links guide you to sections where you can find more detailed information on the individual steps gt Atfirst please take notice of the safety instructions in c
34. alidated The installation indicated on this note is sometimes changed to the kind of possible options without notice Follow the safety instructions in the chapter Important information on page 27 RX600 S5 Operating Manual 91 CSS components In the PRIMERGY RX600 S5 server the following components are considered to be CSS components Hot plug components Hot plug power supply units see page 93 Hot plug fans see page 97 Hot plug HDD modules see page 100 Hot plug memory boards see page 115 Expansion cards in hot plug PCle slots slots 6 amp 7 only see page 107 You can expand or replace the hot plug components during operation Non hot plug components Expansion cards in non hot plug slots see page 122 These components can be changed by you in the event of an error Expansions and upgrades may only be carried out by authorized specialist personnel 92 Operating Manual RX600 S5 CSS components Hot plug components 8 1 Hot plug components This section describes how to handle hot plug components and how to modify your server hardware e g adding replacing hot plug power supply units The hot plug procedure increases the availability of system operation and guarantees a high degree of data integrity and failsafe performance 8 1 1 Hot plug power supply units The server must have at least two hot plug power supply units PSUs to ensure redundant power supply I
35. and left support systems PRIMERGY rack installation depth al Front left support upright a2 Front right support upright b1 Rear left support upright b2 Rear right support upright 44 Operating Manual RX600 S5 Hardware installation Rack installation removal of server ee o N D U a D A N Z D 3 m 3 a 3 Q lt N 1 A a 3 C 450mm 1 6mm 3 B B Figure 2 Mechanical requirements RX600 S5 Operating Manual 45 Rack installation removal of server Hardware installation You must ensure that the safety mechanisms on the server e g stoppers or retaining systems are functioning correctly The shape of the rack support uprights must ensure that the support systems can be bolted to the front The support systems have a linear alignment feature to ensure that they can be adjusted to different rack depths No cable management support delivered with the mounting kit Climatic conditions An unobstructed air intake in the rack front and air discharge in the rear cover of the rack are essential for ventilation of the installed server In general the ventilation concept ensures that the necessary cooling is achieved by the horizontal self ventilation of the installed devices air flow from the front to the rear Power supply For installation in 3rd party racks you must ensure that the appropriate socket strips are present
36. ate recognition handles and locks touch points are color coded Green touch points are for components that can be replaced without tools as well as for hot plug components that can be replaced or inserted during operation without the need for tools see also CSS components on page 91 You can use the ServerView Local Service Display on the front panel of the server to check the status of the key system components at any time without opening the housing Further information on ServerView Local Service Display is provided in the associated documentation For further information please refer to the diagnosis LEDs on the hot plug components power supply units fans expansion cards HDD modules The ServerView Update Manager supplied with the Fujitsu utilities supports a fast remote BIOS update via the LAN interface the BIOS can also be updated locally via USB The optional ServerView Remote Management remote testing and diagnostic system enables you to remotely maintain your server 20 Operating Manual RX600 S5 Preface Features ServerView Remote Management ServerView Remote Management is the remote management solution from Fujitsu for PRIMERGY servers ServerView Remote Management and the relevant hardware components integrated on the system board allow remote monitoring and maintenance as well as fast restoration of operation in the event of errors Remote monitoring and maintenance avoids time consuming and costly on site
37. ation Manager on the ServerView Suite DVD 1 provided you can conveniently configure the server and install the operating system This includes configuring the server specific settings using the ServerView Configuration Manager and configuring the RAID controller using the ServerView RAID Manager Advantages of the ServerView Installation Manager Wizard assisted configuration of your server hardware and disk arrays Wizard assisted installation of all leading server operating systems Wizard assisted creation of configuration files for unattended installation of several PRIMERGY servers with identical hardware configurations Installation of drivers and additional software The software that can be installed depends on your server s hardware configuration This configuration is detected automatically Descriptions of operating systems not covered in the RAID controller manual are provided in the corresponding readme files on the driver CDs To find out how to operate the ServerView Installation Manager and for further information refer to the associated manual If you are using the ServerView Installation Manager you can skip the following section on how to configure the server and install the operating system Continue from section Cleaning the server on page 81 RX600 S5 Operating Manual 79 Configuring the server Starting up and operation 5 3 3 Configuring the server and installing the operating system wi
38. ator 64 66 ESD 34 hard disk drive 15 EMC directive 23 installation frame 100 EMC regulations 103 106 111 124 harddisk indicators 63 ENERGY STAR 35 HDD busy indicator 68 environment class 24 HDD fault indicator 68 environmental protection 39 HDD module 100 error acclimatization time 41 drifting display on monitor 87 installation frame 104 drive dead 88 installing removing 104 drive defective 89 HDD SSD drives incorrect date 88 handling 101 incorrect time 88 hot plug components no display on monitor 87 expansion cards 107 power on indicator does not fans 16 97 light 85 HDD modules 100 screen remains blank 86 memory boards 115 screen shows flickering PCI slots 15 stripes 87 PSUs 93 server switches itself off 86 hot spare memory 16 error correcting code 16 error correction 85 l error detection code 16 ID button 64 65 error message on screen 89 ID card 63 64 expansion cards 107 product name 42 64 serial number 42 64 F ID indicator 64 66 fans 16 IME 78 fault indicators drifting display on monitor 87 CSS 64 66 69 drive defective 89 DVD drive 67 incorrect date 88 global error 64 67 70 incorrect time 88 hard disk 63 no display on monitor 87 hard disk activity 64 66 screen remains blank 86 HDD busy 68 screen shows flickering HDD fault 68 stripes 87 ID 64 66 FCC statement 36 operating 66 operation 64 G optical drive 63 global error indicator 64 67 70 PSU 73 ServerView Local Service Display 67 144 Operating Manual RX600 S5
39. be replaced during operation for further details see Hot plug power supply units on page 93 Cooling Each processor has a heat sink Further cooling for the installed processors is provided by hot plug fans optionally in a redundant configuration Temperature sensors variably adjust the fans If a temperature sensor fails or is removed the fans affected run at maximum speed so as to provide the greatest possible protection for the hardware When the housing is open all the fans run at maximum speed If a fan fails unimpaired further operation is ensured A defective fan module can be replaced during operation for further details see Hot plug fans on page 97 High level of availability and data security When memory data is accessed 1 bit errors in the main memory are identified and automatically corrected with the ECC Error Correcting Code method The patented memory scrubbing function regularly starts up the EDC mechanism Error Detection Code and thus ensures continuous data integrity The memory modules used support SDDC technology Chipkill which further increases the effectiveness of memory error monitoring and correction Support is likewise provided for hot spare memory technology in which a memory module is used like a replacement module If a memory module fails the module with the defective memory is automatically deactivated and the replacement module is activated provided it has been configured for app
40. cific Rack W x D x H 482 6 mm Bezel 445 mm Body x 770 x 176 mm Mounting Depth Rack 728 mm Height Unit Rack 4U 19 rackmount Yes Mounting cable depth rack 100 mm 1000 mm rack recommended Environmental Noise emission Measured according to ISO 7779 and declared according to ISO9296 Sound pressure 46 dB A idle 51 dB A operating LpAm Sound power LWAd 6 2 B idle 6 6 B operating 1B 10dB Noise notes at ambient temperature lt 23 C description Operating ambient temperature 10 35 C Operating relative humidity 10 85 non condensing Exhaust air volume Ambient temp m h m min lt 25 C 49 0 82 30 C 87 1 45 35 C 126 2 1 140 Operating Manual RX600 S5 Appendix server specification Electrical values Power supply configuration Up to 4 hot plug power supplies Base unit equipped with 2 power supplies redundancy as option redundancy Max output of single 850 W power supply Hot plug power supply Yes Rated voltage range 100 127 V 200 240 V typical config Rated frequency range 50 60 Hz Active power min 750 W typical config Active power max 1950 W Rated active power max 3360 W 14 A x 240 V Apparent power max per system unit 1990 VA Heat emmission 7020 0 kJ h 6653 7 BTU h RX600 S
41. cover upwards RX600 S5 Operating Manual 135 Opening Closing the server CSS components 8 3 2 Closing the server CAUTION The housing cover must be replaced as soon as possible for purposes of cooling to comply with EMC regulations regulations regarding electromagnetic compatibility and to prevent fires Figure 52 Placing the housing cover Place the housing cover onto the server such that it projects approx 2 cm at the back see circle in figure above Push the housing cover as far as possible in the direction of the arrow Fasten the little screw see circle in figure 51 on the cover 136 Operating Manual RX600 S5 9 Appendix server specification This section explains the specifications for the server The specifications for this server are liable to be updated without any notice Please be forewarned System Board System board type D2870 Chipset Intel Xeon 7500 Platform Processor Processor quantity and type 2 4 x Intel Xeon processor 7500 series Processor notes A mimimum of 2 processors must be configured no mix of different processor types Memory Modules Configuration Memory slots 64 distributed on 8 memory boards with 8 slots each Memory slot type DIMM DDR3 registered Memory capacity min max 8 GB 1024 GB Memory protection Advanced ECC Memory scrubbing SDDC Memory mi
42. d on the rear of the server when the ID button is pressed Both ID indicators are synchronized On Off button When the system is switched off it can be switched on again by pressing the On Off button When the system is operating pressing the On Off button will switch off the system CAUTION Risk of loss of data The On Off button does not disconnect the server from the mains voltage To disconnect from the mains completely remove the power plug s Reset button Pressing the reset button reboots the system CAUTION Risk of loss of data NMI button CAUTION Do not press Risk of loss of data The NMI button may only be used by service RX600 S5 Operating Manual 65 Control elements and indicators Starting up and operation 5 1 1 2 ID css Indicators on the control panel ID indicator blue Lights up blue when the system has been selected by pressing the ID button To deactivate press the button again The ID indicator can also be activated via the ServerView Operations Manager and the iRMC S2 Web interface and its status reported to the ServerView Operations Manager and the iIRMC S2 Power on indicator green orange yellow Lights up green and also lights up orange for less than one second when the server is switched ON Flashes green when the system is in standby mode Lights up orange when the server is in shutdown mode operating system shutdown or is switched off Lig
43. ditional information notes and tips 1 5 Technical data Electrical data hot plug power supply unit Rated voltage range 100 127 V 200 240 V Frequency 50 Hz 60 Hz Rated current basic configuration 3 1 A 240 V Max rated current 14 A 240 V Active power min typical configuration 750 W Active power max typical configuration 1950 W Rated active power max 3360 W 14 A x 240 V Apparent power typical configuration 1990 VA Heat dissipation 750 W h 2559 btu h 1950 W h 6654 btu h 3360 W h 11465 btu h Main power fuse 16A Protection class 22 Operating Manual RX600 S5 Preface Technical data Compliance with regulations and standards Product safety and ergonomics IEC 60950 1 2 EN 60950 1 2 UL CSA 60950 1 2 CNS 14336 GB 4943 EN 50371 Electromagnetic compatibility Interference emissions Interference immunity EN 55022 class A FCC class A CNS 13438 class A VCCI class A AS NZS CISPR 22 class A GB 9254 class A GB 17625 ETSI EN 300 386 V1 3 1 EN 55024 EN 300386 Harmonic current EN 61000 3 2 Flicker EN 61000 3 3 CE marking to EU Low Voltage Directive 2006 95 EC product safety directives Electromagnetic compatibility 2004 108 EC Environmental conditions ETSI 300 019 2 3 Class 3 1 T3 1 Noise emission ETSI 300 753 Class 3 1 RX600 S5 Operating Manu
44. ds including the SAS SATA RAID controller card e Eight hard disk drives e One optical drive e One tape drive The hot swap feature allows the user to replace a failed power supply module without affecting the system functionality 56 Operating Manual RX600 S5 Hardware installation Connecting the server to the mains AC source related power supply configuration and system load limits The system configuration and load is limited by the number of AC mains power sources available as indicated in the following table 2 PSUs connected to an isolated AC source e g UPS 2 2 Number AC redundant systems AC non redundant systems of power requires 2 AC sources connected to 1 AC source supply Max DC Installation Max DC Installation modules loading to requirements loading for AC requirements installed Support AC non redundant redundancy systems 2 830W 2 PSUs 1580W 2 PSUs connected to connected to mains 1 1 mains 1 1 3 N A N A 2320W 3 PSUs connected to mains 2 1 4 1580W 2 PSUs 2320W 4 PSUs connected to connected to mains mains 3 1 Table 4 System power supply configuration and system load limits Installation in PRIMECENTER Datacenter rack Please follow the installation requirements for connection to the mains described in the rack manuals RX600 S5 Operating Manual 57 Connecting the server to the mains Hardware installation Installation in 3 4
45. e defective fan is identified from the indicator on each fan see figure 21 on page 97 Figure 21 Indicator on a hot plug fan RX600 S5 Operating Manual 97 Hot plug components CSS components 8 1 2 1 Replacing a defective fan Figure 22 Unlocking a fan module and removing it gt Press the two green handles and lift the fan module out of the housing see figure 22 CAUTION Never leave the fan module slot empty for more than two minutes during operation Otherwise excessive temperatures could damage system components gt Insert the new fan module in the empty slot until it clicks into place To make sure the fan has engaged press again The new fan module is tested by Server Management The LED then either does not light at all fan is ok or lights up fan is not ok gt Close the server see Opening Closing the server on page 134 98 Operating Manual RX600 S5 CSS components Hot plug components 8 1 2 2 Adding new fans gt Open the server see Opening Closing the server on page 134 gt Insert the new fan modules in the empty slots until they engage To make sure the fan has engaged press again The new fan module is tested by Server Management The LED then either does not light at all fan is OK or lights up fan is not ok gt Close the server see Opening Closing the server on page 134 RX600 S5 Operating Manual 99 Hot plug components CSS co
46. e optical port plug gt lf present remove the protective optical port plug from the SFP transceiver module CAUTION Save the protective port plug for future use 126 Operating Manual RX600 S5 CSS components Non hot plug components Figure 43 Unlatching the locking bail gt Carefully unlatch and fold down the locking bail on the SFP transceiver module to eject the transceiver from the socket connector RX600 S5 Operating Manual 127 Non hot plug components CSS components Figure 44 Removing the SFP transceiver gt Pull the SFP transceiver module out of its socket connector gt Reattach the protective optical port plug to the transceiver optical bores Place the removed SFP transceiver module in an antistatic bag or other protective environment 128 Operating Manual RX600 S5 CSS components Non hot plug components 8 2 3 2 Installing SFP transceiver modules Figure 45 Removing the protective optical port plug gt Remove the SFP transceiver module from its protective packaging gt Remove the optical port plug from the new additional SFP transceiver module CAUTION Always keep the protective port plugs attached to the transceiver optical bores and fiber optic cable connectors until you are ready to make a connection Save the protective port plug for future use RX600 S5 Operating Manual 129 Non hot plug components
47. e your hands from lever 1 as soon as the power supply unit has been pulled out a few centimeters gt Completely remove the defective power supply unit from the slot CAUTION Never leave the slot for the power supply unit empty for more than two minutes during operation Otherwise excessive temperatures could damage system components 94 Operating Manual RX600 S5 CSS components Hot plug components gt Slide the new power supply unit into the empty slot until it clicks into place Make sure that the new power supply unit engages correctly in the i mounting location and is locked in position This is the only way to prevent the power supply unit from sliding out of its mountings and being damaged during transportation gt Thread the cable through the cable clamp see figure 11 on page 60 gt Pull the cable clamp tight to secure the power cord gt Connect the newly installed power supply unit to the mains If everything is functioning correctly the green LEDs 1 and 3 see Indicators on the hot plug power supply units on page 73 at the rear of the power supply unit will now light up 8 1 1 2 Adding a hot plug power supply unit Figure 20 Removing a PSU dummy module gt Remove the PSU dummy module as follows 1 Press the two metal clips together see arrows 1 in figure above 2 Pullthe PSU dummy module out of its slot see arrow 2 in figure above gt Slide the new power supply
48. ecure the support systems as described in Installing the support systems on page 48 gt Mount the server see Inserting the server on page 50 and route the cables as described in the original manual of the rack CAUTION Ensure that the safety lock has been inserted before the server is inserted see figure 4 on page 48 52 Operating Manual RX600 S5 Hardware installation Connecting devices to the server 4 3 Connecting devices to the server The connectors for external devices are on the front and rear of the server The additional connectors available on your server depend on the expansion cards installed e g optional SAS connector Some of the devices that can be connected may require special software e g drivers see the documentation for the connected device Figure 8 Connectors on the front On the front of the server are a video connector 1 and three USB connectors 2 The two video connectors on the front and rear see figure 9 on page 54 can only be used alternatively the connector not used is automatically deactivated RX600 S5 Operating Manual 53 Connecting devices to the server Hardware installation The standard connectors on the rear are marked with symbols and one is color coded T 8 rO Sen 5 LLALL PT a i Figure 9 Connectors on the rear 4x LAN connector 4 Video connector blue Serial connector COM1
49. ed to the server if this requirement is not met Only transport the server in the original packaging or in packaging that protects it from impacts and jolts Installation and operation CAUTION This unit should not be operated in ambient temperatures above 35 C If the unit is integrated into an installation that draws power from an industrial power supply network with an IEC309 connector the power supply s fuse protection must comply with the requirements for non industrial power supply networks for type A connectors The unit automatically adjusts itself to a mains voltage in a range of 100 127 V 200 240 V Ensure that the local mains voltage lies within these limits This device must only be connected to properly grounded power outlets or insulated sockets of the rack s internal power supply with tested and approved power cords Ensure that the device is connected to a properly grounded power outlet close to the device 28 Operating Manual RX600 S5 Important information Safety instructions CAUTION Ensure that the power sockets on the device and the properly grounded power outlets are freely accessible The On Off button or the main power switch if present does not isolate the device from the mains power supply To disconnect it completely from the mains power supply unplug all network power plugs from the properly grounded power outlets Always connect the server and the attached peripherals to
50. em time For example the operating system time may deviate from the system time under Linux and would overwrite the system time in the default setting on shutdown If the date and time are still wrong after the server has been switched off and back on again replace the lithium battery for a description refer to the Technical Manual for the D2870 system board or contact our customer service team 7 7 Drives reported as dead when starting system RAID controller configuration incorrect gt Check and correct the settings for the drives using the RAID controller utility Further information is provided in the manual for the RAID controller 88 Operating Manual RX600 S5 Troubleshooting and tips Added drive reported as defective 7 8 Added drive reported as defective RAID controller is not configured for this drive The drive was probably installed when the system was switched off gt Reconfigure the RAID controller for the drive using the corresponding utility Information is provided in the documentation for the RAID controller or gt Remove and reinstall the drive while the system is switched ON If the hard disk drive continues to be shown as defective then replace it see Hot plug HDD modules on page 100 7 9 Error message on screen The meaning of the error message is explained in the documentation for the relevant components and programs on the ServerView Suite DVD 2 RX600 S5 Operating Manual 89 Er
51. ents Quick Start Hardware PRIMERGY RX600 S5 leaflet KECHI BRA lt TES LY PRIMERGY RX600 S5 for the Japanese market only included as a printed copy Quick Start Software Quick Installation Guide DVD booklet only included with the ServerView Suite as a printed copy except for the Japanese market Safety Notes and Regulations manual 2 Q CEE for the Japanese market Warranty manual RET for the Japanese market ServerView Suite Local Service Concept LSC manual Returning used devices manual and Service Desk leaflet 7R k amp O ERZR for the Japanese market PRIMERGY RX600 S5 Server Operating Manual PRIMERGY RX600 S5 Server Options Guide System Board D2870 for PRIMERGY RX600 S5 Technical Manual D2870 BIOS Setup Utility for PRIMERGY RX600 S5 manual Operating Manual RX600 S5 Preface Documentation overview il PRIMERGY manuals are available in PDF format on the ServerView Suite DVD 2 The ServerView Suite DVD 2 is part of the ServerView Suite supplied with every server If you no longer have the ServerView Suite DVDs you can obtain the relevant current versions using the order number U15000 C289 the order number for the Japanese market please refer to the configurator of the server http primeserverfujitsu com primergy system html The PDF files of the manuals can also be downloaded free of charge from the Internet The overview page showing the online documentation ava
52. et does not have a protective earth then the service person requires arranging Installation of a protective earth conductor from the system to the building installation The grounding bolt is located on the chassis rear left side wall designated by the L symbol 58 Operating Manual RX600 S5 Hardware installation Connecting the server to the mains Figure 10 Installing a protective earth conductor gt Loosen the first nut and remove it 1 gt Plug the protective earth conductor onto the bolt 2 gt Replace the nut and tighten it 3 RX600 S5 Operating Manual 59 Connecting the server to the mains Hardware installation 4 4 2 Connecting the power cord gt Connect the power cord to the server power supply unit gt Connect the mains plug to a grounded mains outlet in the in house power supply network or a power outlet of the socket strip in the rack see Technical Manual for the rack gt Secure the power cords in the cable clamps so the insulated connectors cannot be disconnected from the server accidentally a canse aa IT Figure 11 Cable clamps to secure the power cords gt Thread the cable through the cable clamp as shown in figure 11 gt Pull the cable clamp tight to secure the power cord Now the insulated connector cannot be disconnected from the server accidentally i
53. f one power supply unit fails the other unit ensures that the operation can continue uninterrupted The defective power supply unit can be replaced during operation hot plug CAUTION e Areas around the power supply unit may remain extremely hot after shutdown Wait for a while after shutdown before removing the power supply unit e When installing the power supply unit be sure to confirm that the connector of the PSU is not damaged or bent e Donot insert your hands in the power supply unit slot when removing the power supply unit Doing so may cause electric shock e Ifthe power supply unit is hard to remove do not pull out it by force e The power supply unit is heavy so handle it carefully If you drop it by mistake injuries may result RX600 S5 Operating Manual 93 Hot plug components CSS components 8 1 1 1 Replacing a hot plug power supply unit Figure 19 Unlocking and removing the power supply unit CAUTION When replacing a non defective hot plug power supply unit in a non redundant configuration the server must be switched off first gt Remove the power cord from the cable clamp You can losen the cable clamp by opening the small locking lever gt Remove the power cord from the installed power supply unit gt Press the green release lever 1 and pull out the power supply unit in the direction of the arrow 2 Grip the handle while pulling the power supply CAUTION Releas
54. g the light pipe switch 1 Wait until the light pipe switch 1 no longer lights up The slot is now zero potential If necessary remove all cables from the expansion card Open the expansion card lock by lifting it up 2 RX600 S5 Operating Manual 109 Hot plug components CSS components The expansion card is now mechanically unlocked gt Hold the removal tool by the green handle and pull it out of the PCI slot together with the expansion card 3 i Do not pull on the expansion card itself Removing an expansion card from the removal tool CAUTION When removing the expansion card from the removal tool pay particular attention to the engaging hooks that fasten the board to the removal tool see arrows in figure 29 Do not lift them by more than approx 1 mm in other words only as far until the expansion card is released Otherwise you could damage the engaging hooks Figure 29 Removing the expansion card from the removal tool gt Lift the green movable engaging hooks see arrows in figure above no more than approx 1 mm until the expansion card is completely released gt Take the expansion card out and put it aside 110 Operating Manual RX600 S5 CSS components Hot plug components Removing engaging hooks Figure 30 Removing engaging hooks from the removal tool gt Push the green engaging hooks down in the direction of the arrows 1 until they disengage from
55. hapter Important information on page 27 and following gt Transport the server to the place where you want to install it gt Unpack all parts check the contents of the package for visible transport damage and check whether the items delivered match the details on the delivery note see section Unpacking the server on page 42 gt Make sure that all necessary manuals see Documentation overview on page 12 are available print out the PDF files if required gt Fit the server in the rack see section Rack installation removal of server on page 43 gt Wire the server Follow the instructions in the sections Connecting devices to the server on page 53 and Notes on connecting disconnecting cables on page 61 gt Connect the server to the mains see section Connecting the server to the mains on page 55 gt Familiarize yourself with the controls and indicators on the front and rear of the server see section Control elements and indicators on page 63 gt Configure the server and install the desired operating system and applications Here you can choose from two possibilities Remote installation with the ServerView Installation Manager With the ServerView Suite DVD 1 provided you can configure the server and install the operating system in a convenient manner Details on how to operate the ServerView Installation Manager as well as some additional information are included in the ServerView Suite
56. hts up yellow during power on delay CSS indicator yellow Lights up yellow if a prefailure event was detected fora CSS component that you can fix yourself for reasons of precaution with the CSS concept Flashes yellow if an error was detected that you can fix yourself with the CSS concept Does not light up when the system is OK If the event is still acute after a power failure the indicator is activated after the restart The indicator also lights up in standby mode For more information on the CSS concept see Customer Self Service CSS on page 14 Hard disk activity indicator green Lights up green when an internal hard disk drive is accessed 66 Operating Manual RX600 S5 Starting up and operation Control elements and indicators N Global Error indicator orange Lights up orange if a prefailure event has been detected that requires precautionary service intervention Flashes orange if an error was detected that requires service intervention Does not light up if there is no critical event If the event is still acute after a power failure the indicator is activated after the restart The indicator also lights up in standby mode You can find more details on the indicated errors in the System Event Log SEL on the ServerView Local Service Display in the ServerView Operations Manager or via the iRMC S2 s Web interface 5 1 1 3 Indicators on the accessible drives com
57. igure 31 Removing the retaining plate from the removal tool gt Lift the green engaging hooks see arrows no more than approx 1 mm until the retaining plate is released 112 Operating Manual RX600 S5 CSS components Hot plug components gt Take the retaining plate out and put it aside i Keep the retaining plate for future use gt Push the engaging hooks down until they disengage from the removal tool see figure 30 on page 111 and keep them in a safe place 8 1 4 4 Installing a hot plug expansion card Inserting an expansion card in the removal tool Figure 32 Inserting the new expansion card in the removal tool gt Insert the new expansion card in the provided slot see oval in figure above of the removal tool gt Insert the green engaging hooks see circles in figure 32 on page 113 in the rods and push them down until they engage in the upper edge of the expansion card CAUTION Make sure that e g the ports on the expansion card are not blocked by the engaging hooks RX600 S5 Operating Manual 113 Hot plug components CSS components Operating the expansion card gt gt Insert the expansion card fastened to the removal tool in the PCI slot Close the slot lock see pos 2 in figure 28 on page 109 by folding it down Make sure that the slot lock engages If necessary connect the cables on the expansion card Activate the expansion card using either the relevant
58. ilable on the Internet can be found using the URL for EMEA market http manuals ts fujitsu com The PRIMERGY server documentation can be accessed using the Industry standard servers navigation option For the Japanese market please use the URL http primeserver fujitsu com primergy manual html Further sources of information PRIMERGY Abbreviations and Glossary on the ServerView Suite DVD 2 Manual for the monitor Documentation for the boards and drives Operating system documentation Information files in your operating system RX600 S5 Operating Manual 13 Features Preface 1 3 Features Customer Self Service CSS The PRIMERGY Customer Self Service CSS concept enables you to identify and replace the affected component yourself in the case of certain error scenarios In the CSS concept you can replace the following components yourself in the event of an error Hot plug hard disk drives Hot plug power supply units Hot plug Memory modules Hot plug System fans Expansion cards as soon as released For information on replacing these components see chapter CSS components on page 91 CSS indicators on the control panel and on the back of the PRIMERGY server provide you with information if a CSS event arises for more information on the behavior of these indicators see chapter Starting up and operation on page 63 and the ServerView Suite Local Service Concept LSC
59. is allows HDD modules to be plugged in or pulled out easily The hard disk system is designed for SAS SATA with one channel for each hard disk drive If the server has the corresponding RAID configuration HDD modules can also be replaced during operation SAS SATA controller card optionally with RAID controller The SAS SATA controller card for operating up to eight SAS SATA hard disk drives can be alternately without or with RAID functionality In case of RAID functionality the levels 0 1 1E 5 6 10 50 and 60 are supported Battery Backup Units Up to two intelligent Battery Backup Units iBBUs back up the memory contents of their corresponding RAID controllers in the event of power failure option Accessible drives components A number of mounting locations are available An installation slot for a ServerView Local Service Display standard An installation slot for a slimline CD DVD BD drive standard A 5 25 inch bay for a magnetic tape drive option RX600 S5 Operating Manual 15 Features Preface The accessible drives components integrated in these locations cannot be replaced during operation Power supply The server has up to four hot plug power supply units that automatically switch to a mains voltage of 100 127 V 200 240 V This ensures redundant power supply If one power supply unit is defective the other s then guarantee s unimpaired operation The faulty power supply unit can
60. k Fujitsu rack systems The main features of PRIMECENTER Rack DataCenter Rack and 19 inch standard rack for the Japanese market are as follows support systems that can be mounted without tools support systems having a linear alignment feature to ensure that they can be adjusted to different rack depths PRIMECENTER Rack and DataCenter Rack provide an enhanced cable management in the lateral rack area RX600 S5 Operating Manual 43 Rack installation removal of server Hardware installation il For PRIMECENTER Racks and DataCenter Racks The mounting of the rails in the different racks is described in the next sections Installation of the cable management is described in detail in the Technical Manual for the respective rack i For 19 inch standard rack for the Japanese market For information on mounting of the rails in the 19 inch standard rack for the Japanese market please refer to the Rack mount guide 3rd party racks Certain general conditions must be met Installation dimensions see the dimensions shown in figure 2 on page 45 1 Front of rack 2 Rear of rack A Rack depth comparison PRIMECENTER Rack 940 1000 1100 mm B Rack width comparison PRIMECENTER rack 700 mm C Clearance for 19 installation level C1 Front 19 installation level C2 Rear 19 installation level D Cable routing area cable area depth and ventilation Space for front panel and ventilation F Space for right
61. lace for cooling to comply with EMC regulations regulations regarding electromagnetic compatibility and for protection against fire Ensure that the dummy module engages correctly in the bay 106 Operating Manual RX600 S5 CSS components Hot plug components 8 1 4 Hot plug expansion cards CAUTION e The actions described in this section may only be performed by personnel with the appropriate technical training The device can be seriously damaged if it is opened without authorization or if repairs are attempted by untrained personnel e Each slot in the server must have either an expansion card or a dummy module A dummy module comprises a retaining plate with an attached removal tool e Please observe the safety information in chapter Important information on page 27 The following operations are possible during operation e Replacement of expansion cards see Removing a hot plug expansion card on page 109 and Installing a hot plug expansion card on page 113 Only expansion cards of the same type and with the same settings may be exchanged If the expansion cards do not match the new expansion card will not be commissioned e Adding more expansion cards see Removing a dummy module on page 112 and Installing a hot plug expansion card on page 113 gt You should read the accompanying documentation supplied with the expansion card beforehand RX600 S5 Operating Manual 107 Hot plug components CSS c
62. ll height all 3 4 length PCI Express Gen2 x16 1 x full height 3 4 length PCI Express x4 mech x8 2 x half height all 1 2 length 138 Operating Manual RX600 S5 Appendix server specification Drive bays Hard disk bay configuration 8 x 2 5 inch hot plug SAS Accessible drive bays 1 x 5 25 0 5 inch for CD RW DVD 1 x 5 25 1 6 inch for backup devices Notes accessible drives all possible options described in relevant system configurator General system information Number of fans 8 Fan configuration hot plug Fan notes Different base units available with 4 fans non redundant or 8 fans redundant Operating Panel Operating buttons On off switch NMI button Reset button ID button Status LEDs System status amber yellow Identification blue Hard disks access green Power amber green At system rear side System status amber yellow Identification blue Service display optional ServerView Local Service Display LSD RX600 S5 Operating Manual 139 Appendix server specification Dimensions Weight Weight up to 46 kg Weight notes Weight may vary depending on actual configuration Rack mounting kit Rack mounting kit as option standard for the japanese market Dimensions Base unit spe
63. ls on the delivery note The product name and serial number of the product can be found on the ID card see section ID card on page 64 gt Notify your supplier immediately should you discover that the items delivered do not correspond to the delivery note 42 Operating Manual RX600 S5 Hardware installation Rack installation removal of server 4 2 Rack installation removal of server CAUTION e Please observe the safety information and notes on rack mounting in chapter Important information on page 27 e Atleast two people are needed to install remove the server in the rack For the Japanese market please refer to EELO E EKU EOWO Stas e The rack may tip over if more than one unit is removed at the same time e The server may not occupy the top height units of the rack 88HU 42HU PRIMECENTER Rack DataCenter Rack 19 inch standard rack for the Japanese market as otherwise boards cannot be replaced 4 2 1 Rack system requirements The rack systems from Fujitsu PRIMECENTER Rack DataCenter Rack and 19 inch standard rack for the Japanese market support the installation of PRIMERGY servers Installation in most current rack systems from other manufacturers 3rd party racks is also supported To accommodate the ventilation concept and ensure proper ventilation any unused areas in the rack must be sealed using dummy covers The power is supplied via the multiple socket outlets fitted in the rac
64. ment for an acclimatization time before it is started up for the first time Temperature difference C Minimum acclimatization time operating environment hours outside 5 10 15 20 OO CO N oO 25 pey oO 30 Table 5 Acclimatization times for HDD SSD modules e Always set the HDD SSD module down carefully with the large surface facing downwards to prevent it from tipping over RX600 S5 Operating Manual 101 Hot plug components CSS components 8 1 3 1 HDD SSD module and dummy module Figure 23 2 5 inch HDD module and dummy module Dummy module Tabs for unlocking the dummy module HDD module installation frame with hard disk drive installed R O M Indicators HDD Busy LED green HDD Fault LED orange For description see section Indicators on the hot plug HDD modules on page 68 Handle for locking and unlocking the HDD module Button for locking and unlocking the handle Ridge for applying a sticker with the current drive name and drive size 102 Operating Manual RX600 S5 CSS components Hot plug components 8 1 3 2 Removing installing the dummy module Free slots are provided with dummy modules Remove the dummy module before installing an additional HDD module Figure 24 Removing installing the 2 5 inch dummy module gt Press both tabs on the dummy module togethe
65. modules on page 68 e Under no circumstances should you remove an HDD module while the system is in operation if you are not sure that the hard disk drive is operated by a RAID controller and belongs to a disk array that is operating in RAID level 1 1E 10 5 50 6 or 60 An HDD module can only be replaced during operation in conjunction with a corresponding RAID configuration e All HDD modules drives must be uniquely identified so that they can be reinstalled in their original mounting locations later If this is not done existing data can be lost If you want to remove an HDD module during operation proceed as follows RX600 S5 Operating Manual 105 Hot plug components CSS components gt If you want to remove an HDD module that is not defective the drive must be first set to Offline via the software RAID controller configuration software gt Unlock the HDD module as described in section Installing the HDD module on page 104 gt Pull the HDD module out a few centimeters gt Wait for at least 60 seconds This period is necessary for the RAID controller to recognize that an HDD module has been removed and for the hard disk drive to come to a stop gt Pull the HDD module out completely gt Install the new HDD module as described in Installing the HDD module on page 104 CAUTION If you have removed an HDD module and do not install a new one in its place put the dummy module back in its p
66. mpatibility and to protect against fire Ensure that the dummy module engages correctly in the slot 124 Operating Manual RX600 S5 CSS components Non hot plug components 8 2 2 2 Installing a non hot plug expansion card Figure 41 Inserting the new expansion card in the removal tool gt gt Insert the new expansion card in the provided slot see oval in figure above of the removal tool Insert the green engaging hooks see circles in figure above in the rods and push them down until they engage in the upper edge of the expansion card CAUTION Make sure that the ports on the expansion card are not blocked by the engaging hooks Insert the expansion card fastened to the removal tool in the PCI slot Close the slot lock see figure 28 on page 109 by folding it down Make sure that the slot lock engages If necessary connect the cables on the expansion card Close the server see Opening Closing the server on page 134 RX600 S5 Operating Manual 125 Non hot plug components CSS components 8 2 3 Replacing SFP transceiver modules For Fiber Channel over Ethernet FCoE configurations the ethernet server adapter is equipped with one or two SFP small form factor pluggable transceiver modules In order to remove install or replace an SFP transceiver module please proceed as follows 8 2 3 1 Removing an SFP transceiver module Figure 42 Removing the protectiv
67. mponents 8 1 3 Hot plug HDD modules The hard disk drives which can be ordered for the PRIMERGY RX600 S5 are supplied already mounted in an installation frame so that defective hard disk drives can be replaced and new hard disk drives can be added during operation The hard disk drive and the installation frame together make up the HDD module CAUTION e The hard disk drive must not be removed from the installation frame by anyone except a service technician e The HDD modules drives must all be marked clearly so that they can be put back in their original places after an upgrade If this is not done existing data can be lost e The hot plug function is only possible in conjunction with a corresponding RAID configuration Further information about the RAID configuration or RAID level can be found in the RAID controller documentation e Do not touch the circuitry on boards or soldered parts Hold the metallic areas or the edges of the circuit boards e Before removing the unit wait for about 30 seconds until the disk stops spinning completely e When the hard disk unit is starting up you may hear a resonant noise for a while but this does not mean a failure e Depending on the OS you can configure the write cache settings for the hard disk drives If a power failure should occur while the write cache is enabled cached data may be lost e When disposing of transferring or returning a hard disk unit wipe out the dat
68. n the USA and other countries Intel and Xeon are trademarks or registered trademarks of Intel Corporation or its subsidiaries in the USA and other countries Before reading this manual For your safety This manual contains important information for safely and correctly using this product Carefully read the manual before using this product Pay particular attention to the accompanying manual Safety notes and other important information and ensure these safety notes are understood before using the product Keep this manual and the manual Safety notes and other important information in a safe place for easy reference while using this product Radio interference This product is a Class A ITE Information Technology Equipment In a domestic environment this product may cause radio interference in which case the user may be required to take appropriate measures VCCI A Aluminum electrolytic capacitors The aluminum electrolytic capacitors used in the product s printed circuit board assemblies and in the mouse and keyboard are limited life components Use of these components beyond their operating life may result in electrolyte leakage or depletion potentially causing emission of foul odor or smoke As a guideline in a normal office environment 25 C operating life is not expected to be reached within the maintenance support period 5 years However operating life may be reached more quickly if for example the product is
69. nch cages s ee eh Owe Gees See eee e 11 1 1 Concept and target groups for this manual 11 1 2 Documentation overview sasaaa aoaaa 12 1 3 FEJES o a c a a a ESR Ee Eee ke ees 14 1 4 Notational conventions sasaaa aoaaa 22 1 5 Techmical Gala bc ceases dee tee ed EE 22 2 Overview of the installation steps 25 3 Important information 0 00282 ee eee 27 3 1 Safety instructions 1 2 0 02 eee eee ee 27 3 2 ENERGY STAR sss seek Sti es Dee ee he ohenee lt 35 3 3 CEEONKHIMNNY 2 262248 2426888 8e de eee owe ee 35 3 4 FCC Class A Compliance Statement 36 3 5 Transporting the server 2 2 02020 eee eee 37 3 6 Notes on installing the server inthe rack 38 3 7 Environmental protection 2 20 8805 39 4 Hardware installation 02 0205 222 eee 41 4 1 Unpacking the server 2 2 2000 eee eee 42 4 2 Rack installation removal of server 5 43 4 2 1 Rack system requirements 2 43 4 2 2 Installation in PRIMECENTER DataCenter rack 46 4 2 3 Installation in 3rd party racks 2 ie ede eee ee eR Re Ho 51 4 3 Connecting devices to the server 2 55 53 4 4 Connecting the server to the mains 55 4 4 1 Installation requirements 2 2804 55 RX600 S5 Operating Manual Contents 4 4 2 4 5 5 1 51 1 5 1 11 S112 5 1 1 3 5 1 1 4 51 2 5 1 21 51 22 5 1 2 3 5 1 2 4 5 2 5 3 6 3 1 5 8 2 5 3
70. not pull on the expansion card itself 122 Operating Manual RX600 S5 CSS components Non hot plug components Removing an expansion card from the removal tool CAUTION When removing the expansion card from the removal tool pay particular attention to the engaging hooks that fasten the board to the removal tool see figure 39 Do not lift them by more than approx 1 mm in other words only as far until the expansion card is released Otherwise you could damage the engaging hooks Figure 39 Removing the expansion card from the removal tool gt Lift the green movable engaging hooks see arrow in figure above no more than approximately 1 mm until the expansion card is completely released gt Take the expansion card out and put it aside RX600 S5 Operating Manual 123 Non hot plug components CSS components Removing engaging hooks Figure 40 Removing engaging hooks from the removal tool gt Push the green engaging hooks down in the direction of the arrow 1 until they disengage from the removal tool gt Remove the engaging hooks 2 and keep them in a safe place gt To insert a new expansion card continue with section Installing a hot plug expansion card on page 113 CAUTION If you remove an expansion card and do not insert a replacement you will have to use a dummy module for better cooling to comply with applicable EMC regulations regulations on electromagnetic co
71. oad at an early stage allowing preventive measures to be taken The ServerView Operations Manager enables the management of all PRIMERGY servers in the network via a central console The ServerView Operations Manager supports the following functions e Round the clock monitoring regardless of server status e High performance graphical console bypass AVR protected by HTTPS SSL 128 bit e Remote storage via USB e Remote power on e Temperature monitoring of the CPU and the surrounding area e Detailed status and error reports for processors and main memory e Watchdog timer for Automatic Server Reconfiguration and Restart ASR amp R in the event of failure of memory modules or processors e Power monitoring e End of life monitoring of fans with prompt notification before failure e Watchdog timer for monitoring the operating system with ASR amp R Further information on the ServerView Operations Manager is provided in the associated documentation RX600 S5 Operating Manual 19 Features Preface ServerView Installation Manager You can configure the PRIMERGY server quickly and precisely with the ServerView Installation Manager software provided User guided menus are available for installing the server operating system for further details see section Configuring the server on page 78 Service and support PRIMERGY servers are service friendly and modular enabling quick and easy maintenance For easier and immedi
72. omponents Figure 27 PCI slots with and without hot plug functionality Item Slot Description 1 10 PCle slot 10 2 9 PCle slot 9 3 8 PCle slot 8 4 7 PCle slot 7 hot plug 5 6 PCle slot 6 hot plug 6 5 PCle slot 5 7 4 PCle slot 4 8 3 PCle slot 3 9 2 PCle slot 2 10 1 PCle slot 1 11 J Dedicated slot for I O riser board 12 A Dedicated slot for SAS controller card Only slots 6 and 7 are hot plug slots These slots are marked with a hot plug label see arrows in figure 27 108 Operating Manual RX600 S5 CSS components Hot plug components 8 1 4 1 Identifying the defective CSS component gt gt Open the server see Opening Closing the server on page 134 Press the Indicate CSS button on the system board see Technical Manual for the system board D2870 on the ServerView Suite DVD 2 The PRIMERGY Diagnostic LED of the defective CSS component lights up orange thereby indicating which CSS component on the system board must be replaced see Technical Manual for details 8 1 4 2 Removing a hot plug expansion card gt If required by the operating system start the PCI hot plug software You will find information about this in the readme file on the ServerView Suite DVD 2 Figure 28 Deactivating unlocking and removing the board gt Deactivate the expansion card using either the relevant PCI hot plug software or by pressin
73. orization or if repairs are attempted by untrained personnel 8 3 1 Opening the server CAUTION The server can be seriously damaged if it is opened without authorization or if repairs are attempted by untrained personnel It is essential to observe the safety instructions in chapter Important information on page 27 Before removing or attaching covers turn off the server all peripheral devices and any other connected devices Also unplug all power cords from the outlet Failure to do so can cause electric shock The housing cover must be replaced as soon as possible for purposes of cooling to comply with EMC regulations regulations regarding electromagnetic compatibility and to prevent fires The housing cover must not remain open for longer than 5 minutes Use the anti tilt plate to prevent the rack from tipping when installing the rack Pulling the server out of the rack without having installed the anti tilt plate may cause the rack to tip over Be careful not to pinch fingers or clothes when sliding out the server or pushing it back Failure to do so may cause injury 134 Operating Manual RX600 S5 CSS components Opening Closing the server pD Ch Figure 51 Opening the server gt Loosen the little screw see circle in figure above and put it on a safe place gt Push the two green touchpoints on the cover and move the cover for approximately 2 cm backwards gt Lift the
74. party racks without main connection according to IEC309 or outside of racks i 1 These additional installation requirements ONLY apply when 4 PSUs are connected to a high line voltages 220V or higher 2 These requirements DO NOT apply when PSUs are connected to low line voltages 100 127V and 200V OR if at least one PSU is connected into a separate AC source e g UPS CAUTION These additional installation requirements are REQUIRED to avoid risk of high leakage current which may result in electric shock 1 Systems REQUIRE being installed in a location having equipotential bonding such as a telecommunication center a dedicated computer room or a RESTRICTED ACCESS LOCATION Definition of RESTRICTED ACCESS LOCATION is a location for equipment where both of the following apply Access can only be gained by SERVICE PERSONS or by USERS who have been instructed about the reasons for the restrictions applied to the location and about any precautions that shall be taken and Access is through the use of a TOOL or lock and key or other means of security and is controlled by the authority responsible for the location 2 The building installation shall provide means for connection to protective earth as follows Connection to protective earth can be provided by the socket outlet that provides power to the PSU A service person requires checking the socket outlet to make sure it has a protective earth If the socket outl
75. ponents DVD drive activity indicator Lights up green when the storage medium is being accessed ServerView Local Service Display You can use the slot mechanism to pull out the ServerView Local Service Display from the server housing and read the information Press the front of the module to release the lock You can also pivot the ServerView Local Service Display down by an angle of 120 from its normal position This makes reading easier when the server is located very high in the rack Further information on using the ServerView Local Service Display is provided in the Customer Self Service CSS manual RX600 S5 Operating Manual 67 Control elements and indicators Starting up and operation 5 1 1 4 Indicators on the hot plug HDD modules Figure 14 Indicators on a hot plug HDD module 1 HDD BUSY green Lights up HDD in active phase drive active drive being accessed Does not light HDD inactive drive inactive 2 HDD FAULT orange Does not light no HDD error Lights up HDD Faulty or Rebuild Stopped drive defective needs replacing a rebuild process was stopped or the HDD module is not correctly inserted Slow flashing HDD Rebuild the data is being restored after changing a drive If a hard disk drive continuously indicates an error the drive should be replaced as soon as possible This can be done during operation see Hot plug HDD modules on page
76. r relocate the receiving antenna e Increase the separation between equipment and the receiver e Connect the equipment into an outlet on a circuit different from that to which the receiver is connected e Consult the dealer or an experienced radio TV technician for help Fujitsu is not responsible for any radio or television interference caused by unauthorized modifications of this equipment or the substitution or attachment of connecting cables and equipment other than those specified by Fujitsu The correction of interferences caused by such unauthorized modification substitution or attachment will be the responsibility of the user The use of shielded I O cables is required when connecting this equipment to any and all optional peripheral or host devices Failure to do so may violate FCC and ICES rules WARNING This is a class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures 36 Operating Manual RX600 S5 Important information Transporting the server 3 5 Transporting the server CAUTION Only transport the server in its original packaging or in packaging that protects it from impacts and jolts Do not unpack the server until it is at its installation location If you need to lift or transport the server ask other people to help you Never lift or carry the device by the handles on the front panel RX600 S5 Operating
77. r until the locking mechanism disengages 1 gt Pull the dummy module out of the bay 2 To install a dummy module follow the same procedure in reverse order CAUTION Store the dummy module in a safe place If you have removed an HDD module and do not install a new one in its place put the dummy module back in its place for cooling to comply with EMC regulations regulations regarding electromagnetic compatibility and for protection against fire Ensure that the dummy module engages correctly in the bay RX600 S5 Operating Manual 103 Hot plug components CSS components 8 1 3 3 Installing the HDD module Figure 25 Unlocking the 2 5 inch HDD module gt Release the locking mechanism as follows 1 Press the two green tabs of the locking lever together 1 2 Push the handle of the HDD module fully in the direction of the arrow 2 The HDD module is now unlocked 104 Operating Manual RX600 S5 CSS components Hot plug components Figure 26 Installing the 2 5 inch HDD module gt Carefully push the HDD module into the empty slot 1 until it stops gt Push the handle completely 2 in the direction of the arrow until the locking mechanism engages 8 1 3 4 Removing the HDD module CAUTION e Only remove an HDD module during operation if the drive is not currently being accessed Observe the control LEDs for the corresponding HDD modules see Indicators on the hot plug HDD
78. re 35 Removing a memory module gt Press the holders on either side of the memory slot concerned outward 1 gt Pull the defective memory module out of the slot 2 118 Operating Manual RX600 S5 CSS components Hot plug components 8 1 5 4 Installing a new memory module CAUTION Observe the safety information concerning memory modules in section Removing a defective memory module on page 117 Figure 36 Installing a memory module gt Carefully press the memory module into the slot 1 until the fastening tabs on both sides of it engage 2 8 1 5 5 Reinstalling the memory board in question Figure 37 Installing a memory board gt Slide the memory board down 1 in the lateral guide channels until it stops Swivel the levers in the direction of the arrows 2 gt Make sure that the green locks on the top engage RX600 S5 Operating Manual 119 Hot plug components CSS components gt Press the ATTN button gt Wait until the ATTN LED is turned off gt Close the server as described in Closing the server on page 136 8 1 5 6 Adding a memory board To add memory boards during operation proceed as follows gt Open the server see Opening the server on page 134 gt Remove the air baffle of the respective memory board slot Figure 38 Removing the memory air baffle to add a memory board gt Press on the top of the memory air baffle 1
79. requirements of the EC directives 2004 108 EC regarding Electromagnetic Compatibility and 2006 95 EC Low Voltage Directive This is indicated by the CE marking CE Communaut Europ enne RX600 S5 Operating Manual 35 FCC Class A Compliance Statement Important information 3 4 FCC Class A Compliance Statement If there is an FCC statement on the device it applies to the products covered in this manual unless otherwise specified herein The statement for other products will appear in the accompanying documentation NOTE This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC rules and meets all requirements of the Canadian Interference Causing Equipment Standard ICES 003 for digital apparatus These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in strict accordance with the instructions may cause harmful interference to radio communications However there is no warranty that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures e Reorient o
80. ropriately in the BIOS The deactivated memory module is no longer used and the faulty memory module can be replaced at the next opportunity In order to be able to use the hot spare memory function all occupied DIMM slots must have an identical memory configuration 16 Operating Manual RX600 S5 Preface Features Memory modules can be protected against failure through mirroring memory mirroring requires two or four memory modules ASR amp R Automatic Server Reconfiguration and Restart restarts the system in the event of an error and automatically hides the defective system components The PDA Prefailure Detection and Analysis technology from Fujitsu analyzes and monitors all components that are critical for system reliability The SAS SATA controller card supports the RAID levels 0 1 1E 5 6 10 50 and 60 thus increasing system availability and reliability Additional reliability is provided by the hot plug HDD modules fans and power supply units RX600 S5 Operating Manual 17 Features Preface iRMC S2 with integrated management LAN connector The features of the IRMC S2 Advanced Video Redirection and Remote Storage are available as an option The iRMC S2 integrated Remote Management Controller is a BMC with integrated management LAN connector and expanded functionality that was previously only available with additional plug in cards In this way the iRMC S2 enables complete control of PRIMERGY server
81. ror message on screen Troubleshooting and tips 90 Operating Manual RX600 S5 8 CSS components This chapter describes how to handle CSS components and how to identify defective CSS components and replace them yourself Further information on the CSS concept is provided in the ServerView Suite Local Service Concept LSC manual on the ServerView Suite DVD 2 For the latest information on optional products provided for the RX600 S5 see the configurator of the server http ts fujitsu com products standard_servers index htm for the EMEA market http primeserver fujitsu com primergy system html for the Japanese market A CAUTION Do not disassemble the power supply unit Doing so may cause electric shock Do not damage or modify internal cables or devices Doing so may cause a device failure fire or electric shock Devices inside the server remain hot after shutdown Wait for a while after shutdown before installing or removing internal options The circuit boards and soldered parts of internal options are exposed and can be damaged by static electricity Before handling them first touch a metal part of the server to discharge static electricity from your body Do not touch the circuitry on boards or soldered parts Hold the metallic areas or the edges of the circuit boards If devices are installed or disassembled using methods other than those outlined in this chapter the warranty will be inv
82. rroring support Hot spare memory support Memory notes Memory modules are installed on memory boards 8 DIMM slots per memory board Two memory boards are preinstalled in base unit further memory boards as option Memory module notes Memory modules will be delivered in sets of 4 DIMMs per order code Intel 7500 Scalable Memory Buffer supports max 1066 MHz memory clock speed 1TB memory capacity will be possible with availability of 16 GB DIMM modules RX600 S5 Operating Manual 137 Appendix server specification Interfaces USB connectors 6 x USB 2 0 8x front 2x rear 1x internal Graphics 15 pin 2 x VGA 1x front 1x rear Serial 9 pin 2 x serial RS 232 C LAN Ethernet RJ 45 4 x Gbit s Ethernet Service LAN RJ45 1 x dedicated service LAN port for iRMC S2 10 100 Mbit s Service LAN traffic can be switched to shared onboard Gbit LAN port Onboard or integrated controllers RAID Controller 8 port RAID 0 1 or RAID 5 6 controller as option Remote Management Controller Integrated Remote Management Controller IRMC S2 32 MB attached memory incl graphics controller IPMI 2 0 compatible Trusted Platform Module TPM Infineon separate module TCG V1 2 compliant option Slots PCI Express Gen2 x4 mech x8 3 x full height 2 x 1 2 length 1 x 3 4 length PCI Express Gen2 x8 4 x fu
83. rvice Display see chapter Starting up and operation on page 63 and the Customer Self Service CSS manual on the ServerView Suite DVD 2 RX600 S5 Operating Manual 115 Hot plug components CSS components 8 1 5 1 Identifying the defective memory The faulty memory module can be identified from the corresponding DIMM Fault LED on the respective memory board see figure 33 when the server is open gt Open the server see Opening the server on page 134 Figure 33 Button and indicators on memory board ATTN button 4 Mirror LED green 2 ATTN LED orange 5 8x DIMM Fault LED orange Power LED green gt Use the DIMM Fault LEDs 5 to identify the faulty memory module The respective DIMM Fault LED lights up orange and indicates the slot on the memory board that is occupied by the faulty memory module Make a note of which LED e g 1B on which memory board is lit orange Press the ATTN button 1 Wait until ATTN LED 2 and Power LED 3 are turned off yY v vyv y Remove the memory board as described in Removing the memory board in question on page 117 116 Operating Manual RX600 S5 CSS components Hot plug components 8 1 5 2 Removing the memory board in question t Figure 34 Example Removing memory board gt Unlock the memory board in question by pressing the green locks 1 The levers on both sides will be released
84. s regardless of system status and thus particularly the control of PRIMERGY servers that are in the out of band system status Major functions supported by the iRMC S2 include the following e Browser access via iRMC S2 s own Web server e Secure communication SSH SSL e Power Management for the managed server depending on its system status e Power Consumption Management e Connecting virtual drives as remote storage e Text based and graphic console bypass Advanced Video Redirection e Command Line Interface CLI e Simple interactive or script based iRMC S2 configuration e Customer Self Service CSS e iRMC S2 s own user management e Multi computer global iRMC S2 user administration using an LDAP Directory Service e Automatic network configuration via DNS DHCP e Power supply of the iRMC S2 via the system standby supply e Full coverage alarm management e System Event Log SEL reading and processing More information about the iRMC S2 can be found in the IRMC S2 integrated Remote Management Controller user s guide on the ServerView Suite DVD 2 under Industry Standard Servers Software ServerView Suite Out Of Band Management 18 Operating Manual RX600 S5 Preface Features Server management Server management is implemented using the ServerView Operations Manager supplied and the PDA Prefailure Detection and Analysis technology from Fujitsu PDA reports the threat of a system error or overl
85. s and soldered parts of internal options are exposed and can be damaged by static electricity Before handling them first touch a metal part of the server to discharge static electricity from your body Do not touch the circuitry on boards or soldered parts Hold the metallic areas or the edges of the circuit boards 30 Operating Manual RX600 S5 Important information Safety instructions CAUTION e Install the screw removed during installation detaching Internal Options in former device position To use a screw of the different kind causes a breakdown of equipment e The installation indicated on this note is sometimes changed to the kind of possible options without notice Batteries CAUTION e Incorrect replacement of batteries may lead to a risk of explosion The batteries may only be replaced with identical batteries or with a type recommended by the manufacturer see the technical manual for the system board e Do not throw batteries into the trash can e Batteries must be disposed of in accordance with local regulations concerning special waste e Replace the lithium battery on the system board in accordance with the instructions in the technical manual for the system board e All batteries containing pollutants are marked with a symbol a crossed out garbage can In addition the marking is provided with the chemical symbol of the heavy metal decisive for the classification as a pollutant Cd Cadmium Hg
86. screen CAUTION Switch off the server immediately Risk of damaging the server Monitor does not support the set horizontal frequency gt Find out which horizontal frequency your monitor screen supports You will find the horizontal frequency also known as line frequency or horizontal deflection frequency in the documentation for your monitor gt Refer to the documentation for your operating system or the software for the screen controller for details of how to set the correct horizontal frequency for your monitor and follow the procedure accordingly 7 5 No screen display or display drifts The wrong horizontal frequency or resolution has been selected for the monitor or for the application program gt Find out which horizontal frequency your monitor screen supports You will find the horizontal frequency also known as line frequency or horizontal deflection frequency in the documentation for your monitor gt Refer to the documentation for your operating system or the software for the screen controller for details of how to set the correct horizontal frequency for your monitor and follow the procedure accordingly RX600 S5 Operating Manual 87 Incorrect date and time Troubleshooting and tips 7 6 Incorrect date and time gt Set the date and time in the operating system or in the BIOS Setup under the Main menu using System Date and System Time respectively Note that the operating system may affect the syst
87. server on and off 5 2 Switching the server on and off CAUTION e f nothing appears on the screen but flickering stripes after switching on the server switch the server off immediately see chapter Troubleshooting and tips on page 85 e The On Off button does not disconnect the server from the mains voltage To completely disconnect it from the mains voltage remove the power plug s from the socket s e Donot move strike or shake the server when it is turned on This can damage the hard disk in the server and cause data loss e Turn the server on when the temperature is in its operating environment range 10 35 C For details on the operating environment refer to Safety Precautions When operating the device outside of this operating environment the server may operate improperly damage data etc Furthermore Fujitsu cannot be held responsible for any related damage malfunction or loss of data etc e Be sure to wait for 10 seconds or more after shutdown before turning the server on e After connecting the power cords press the On Off button after it passes for more than 10 seconds Switching the server on The power on indicator see figure 13 on page 64 lights up orange standby mode when the server is connected to the mains Starting up for the first time For the Japanese market please refer to IL COIL BRAK ESL gt Press the On Off button see figure 13 on page 64 gt Insert ServerView S
88. signal in the event of a LAN transfer rate management of 100 Mbit s LAN Remains dark in the event of a LAN transfer rate of 10 Mbit s 72 Operating Manual RX600 S5 Starting up and operation Control elements and indicators LAN link transfer management LAN Steady green signal when a LAN connection exists Remains dark when no LAN connection exists Flashes green when LAN transfer takes place 5 1 2 4 Indicators on the hot plug power supply units Figure 18 Indicators on the power supply units DC power Lights up green when PSU is running pecunaalicy Flashes green when PSU is in cold redundancy mode indicator PSU failure Lights up amber in case of a critical event PSU and warnings shutdown indicator Flashes amber in case of a warning event operation continue AC power Lights up green if AC power is present supply input Flashes green if AC power is not present status indicator RX600 S5 Operating Manual 73 Control elements and indicators Starting up and operation In normal server operation LED 1 and 3 light up permanently LED 2 does not light up As soon as LED 2 indicates a fault by lighting up the affected power supply unit should be replaced as soon as possible This can be done during operation see Hot plug power supply units on page 93 74 Operating Manual RX600 S5 Starting up and operation Switching the
89. structions in the chapter Important information on page 27 e Do not expose the server to extreme environmental conditions see Ambient conditions on page 24 Protect the server from dust humidity and heat e Make sure that the server is acclimatized for the time indicated in this table before putting it into operation Temperature difference C Minimum acclimatization time hours 5 3 10 5 15 7 20 8 25 9 30 10 Table 1 Acclimatization time In the table Acclimatization time the temperature difference refers to the difference between the operating environment temperature and the temperature to which the server was exposed previously outside transport or storage temperature RX600 S5 Operating Manual 41 Unpacking the server Hardware installation 4 1 Unpacking the server gt gt CAUTION Follow the safety instructions in chapter Important information on page 27 The server must always be lifted or carried by at least two people For the Japanese market please refer to R amp ENDER Do not unpack the server until it is at its installation location Transport the server to the place where you want to set it up Unpack all individual parts Keep the original packaging in case you want to transport the server again applies only to EMEA market Check the delivery for any damage during transport Check whether the items delivered match the detai
90. systems used for critical business applications This will result in the system to continue operation during a power failure as the redundant part of the subsystem is plugged into a separate AC source e g uninterruptable power supply UPS Refer to tables below for maximum DC loading for both AC redundant and AC non redundant configurations Installation requirements for AC redundant configurations The AC redundant configuration is with two PSU plugged into a main AC source and two other PSUs plugged into a separate AC source e g UPS PSU Configuration Max DC Loading DC Redundancy 1 1 2 PSUs 830W Yes 2 2 4 PSUs 1580W Yes Table 2 Maximum DC Loading Requirements RX600 S5 Operating Manual 55 Connecting the server to the mains Hardware installation Installation requirements for AC non redundant configurations For systems not requiring AC redundancy the power supply subsystem can be installed with up to 4 PSUs The PSUs can be connected to a single or multiple AC sources PSU Configuration Max DC Loading DC Redundancy 1 1 2 PSUs 830W Yes 2 1 3 PSUs 1580W Yes 3 1 4 PSUs 2320W Yes Table 3 Maximum DC Loading Requirements Three power supply modules are capable of handling the maximum power requirements for a fully configured PRIMERGY RX600 S5 server system which include the following e Four processors e 1024 GB of memory e Eleven PCle add in car
91. t touch any connectors or conduction paths on an ESD e Place all the components on a pad which is free of electrostatic charge For a detailed description of how to handle ESD components see the relevant European or international standards EN 61340 5 1 ANSI ESD 20 20 34 Operating Manual RX600 S5 Important information ENERGY STAR Other important information e During cleaning observe the instructions in section Cleaning the server on page 81 e Keep this operating manual and the other documentation such as the technical manual documentation DVD close to the device All documentation must be included if the equipment is passed on to a third party 3 2 ENERGY STAR 3 3 d ENERGY STAR Products that have been certified compliant with ENERGY STAR and identified as such are in full compliance with the specification at shipping Note that energy consumption can be affected by software that is installed or any changes that are made to the hardware configuration or BIOS or energy options subsequently In such cases the properties guaranteed by ENERGY STAR can no longer be assured The ServerView Operations Manager user guide contains instructions for reading out measurement values including those relating to current energy consumption and air temperatures Either the Performance Monitor or the Task Manager can be used to read out CPU utilization levels CE conformity The system complies with the
92. tarting up and operation 5 3 Configuring the server This section contains information about configuring the server and installing the operating system Make sure that the energy saving functions are disabled in the BIOS Setup during server operation 5 3 1 Configuring the SAS SATA RAID controller card The server comes with a SAS SATA RAID controller with MegaRAID functionality You can configure the SAS SATA RAID controller either before or during installation with the ServerView Installation Manager Using the ServerView Installation Manager is recommended A separate utility is available to the controller for MegaRAID i configuration For further information refer to the SAS Software User s Guide on the ServerView Suite DVD 2 under Industry Standard Servers Expansion Cards Storage Adapters LSI Configuration Software Further information on modular RAID controllers is provided in the Modular RAID Controller Installation Guide on the ServerView Suite DVD 2 under Industry Standard Servers Expansion Cards Storage Adapters LSI RAID SCSI Controllers Descriptions of operating systems not covered in the controller manual are provided in the corresponding readme files on the driver CDs 78 Operating Manual RX600 S5 Starting up and operation Configuring the server 5 3 2 Configuring the server and installing the operating system with the ServerView Installation Manager Using the ServerView Install
93. tended environment please contact your sales outlet or our customer service team CAUTION e The actions described in this manual shall be performed by technical specialists A technical specialist is a person who is trained to install the server including hardware and software e Repairs to the device that do not relate to CSS failures shall be performed by service personnel Please note that unauthorized interference with the system will void the warranty and exempt the manufacturer from all liability e Any failure to observe the guidelines in this manual and any improper repairs could expose the user to risks electric shock energy hazards fire hazards or damage the equipment e Before installing removing internal options to from the server turn off the server all peripheral devices and any other connected devices Also unplug all power cords from the power outlet Failure to do so can cause electric shock RX600 S5 Operating Manual 27 Safety instructions Important information Before starting up CAUTION During installation and before operating the device observe the instructions on environmental conditions for your device see Technical data on page 22 If the server has been moved from a cold environment condensation may form both inside and on the outside of the machine Wait until the server has acclimatized to room temperature and is absolutely dry before starting it up Material damage may be caus
94. the same power circuit Otherwise you run the risk of losing data if for example the server is still running but a peripheral device e g memory subsystem fails during a power outage Data cables must be adequately shielded Ethernet cabling has to comply with EN 50173 and EN 50174 1 2 standards or ISO IEC 11801 standard respectively The minimum requirement is a Category 5 shielded cable for 10 100 Ethernet or a Category 5e cable for Gigabit Ethernet Route the cables in such a way that they do not create a potential hazard make sure no one can trip over them and that they cannot be damaged When connecting the server refer to the relevant instructions in this manual Never connect or disconnect data transmission lines during a storm risk of lightning hazard Make sure that no objects e g jewelry paperclips etc or liquids can get inside the server risk of electric shock short circuit In emergencies e g damaged casing controls or cables penetration of liquids or foreign bodies switch off the server immediately remove all power plugs and contact your sales outlet or customer service team RX600 S5 Operating Manual 29 Safety instructions Important information CAUTION Proper operation of the system in accordance with IEC 60950 1 2 resp EN 60950 1 2 is only ensured if the casing is completely assembled and the rear covers for the installation slots have been fitted electric shock cooling fire
95. thout the ServerView Installation Manager Installing the operating system gt Insert the CD DVD BD for the operating system you want to install gt Reboot the server gt Follow the instructions on screen and in the manual for the operating system 80 Operating Manual RX600 S5 Starting up and operation Cleaning the server 5 4 Cleaning the server CAUTION Switch the server off and disconnect the power plugs from the properly grounded power outlets Do not clean any interior parts yourself leave this job to a service technician Do not use any cleaning agents that contain abrasives or may corrode plastic Ensure that no liquid enters the system Ensure that the ventilation areas of the server and the monitor are clear Do not use any cleaning sprays including flammable types It may cause a device failure or a fire Clean the keyboard and the mouse with a disinfecting cloth Wipe the server and monitor casing with a dry cloth If particularly dirty use a cloth that has been moistened in a mild domestic detergent and then carefully wrung out RX600 S5 Operating Manual 81 Cleaning the server Starting up and operation 82 Operating Manual RX600 S5 6 Property and data protection 6 1 Mechanical access protection The lockable rack door protects the server against unauthorized access 6 2 BIOS Setup security functions The Security menu in BIOS Setup offers various options for protecting
96. time Keep the optical disk tray closed to prevent foreign matter such as dust from entering the optical drive Hold CDs DVDs BDs by their edges to avoid contact with the disk surface 32 Operating Manual RX600 S5 Important information Safety instructions e Do not contaminate the CD DVD BD surface with fingerprints oil dust etc If dirty clean with a soft dry cloth wiping from the center to the edge Do not use benzene thinners water record sprays antistatic agents or silicone impregnated cloth e Be careful not to damage the CD DVD BD surface e Keep the CDs DVDs BDs away from heat sources e Do not bend or place heavy objects on CDs DVDs BDs e Do not write with ballpoint pen or pencil on the label printed side e Donotattach stickers or similar to the label side Doing so may cause rotational eccentricity and abnormal vibrations e When aCD DVD BD is moved from a cold place to a warm place moisture condensation on the CD DVD BD surface can cause data read errors In this case wipe the CD DVD BD with a soft dry cloth then let it air dry Do not dry the CD DVD BD using devices such as a hair dryer e To avoid dust damage and deformation keep the CD DVD BD in its case whenever it is not in use e Do not store CDs DVDs BDs at high temperatures Areas exposed to prolonged direct sunlight or near heating appliances are to be avoided You can prevent damage from the optical drive and the CDs DVDs BDs
97. ting cables Hardware installation 62 Operating Manual RX600 S5 5 Starting up and operation CAUTION Follow the safety instructions in chapter Important information on page 27 5 1 Control elements and indicators 5 1 1 Front of server Figure 12 Front overall view 1 ID card 5 Video connector O 2 ServerView Local Service 3x USB connector Display 3 Optical drive activity indicator 7 Hard disk indicators Control panel for details see 8 Tape optional page 64 The white numbers in figure 12 show the HDD slot assignment RX600 S5 Operating Manual 63 Control elements and indicators Starting up and operation Figure 13 Front detailed view control panel 1 ID indicator 6 Reset button 2 CSS indicator 7 NMI button 3 Global Error indicator 8 On Off button 4 Hard disk activity indicator 9 ID button 5 Power on indicator ID card You can pull out the ID card see figure 12 above as far as it will go and push it back in again The ID card contains various system information such as product name serial number and order number in the Japanese market only the product name and the serial number 64 Operating Manual RX600 S5 Starting up and operation Control elements and indicators 5 1 1 1 ID RST NMI Control elements ID button ID LED lights up blue on the front an
98. ting the server on page 50 RX600 S5 Operating Manual 49 Rack installation removal of server Hardware installation Inserting the server For the Japanese market Refer to the Rack Mounting Guide for more detailed explanation and for other support systems Figure 6 Inserting the server a Figure 7 Inserting the server b 50 Operating Manual RX600 S5 Hardware installation Rack installation removal of server CAUTION Ensure that the safety lock has been inserted before the server is inserted see figure 4 on page 48 CAUTION At least two people are needed to position the server in the rack For the Japanese market please refer to R amp EDFEBKEKUTOMWO BERR gt Extend the telescopic rails completely to the front 1 il They must click into place so that they can no longer be moved gt Lower the server from above onto the projecting telescopic rails 2 3 As you do this the locking bar 4 engages gt Push the locking mechanism of both telescopic rails up 5 gt Push the server as far as it will go into the rack 6 gt Fasten the server to the rack 7 using the two knurled screws front panel Torque 0 25 Nm gt Route the cables as described in the Technical Manual for the rack in question with the server pushed in 4 2 3 Installation in 3rd party racks The support systems from Fujitsu are suitable for use in any 3rd party racks for standard
99. uite DVD 1 in the DVD drive gt Follow the on screen instructions see also section Configuring the server and installing the operating system with the ServerView Installation Manager on page 79 or section Configuring the server and installing the operating system without the ServerView Installation Manager on page 80 RX600 S5 Operating Manual 75 Switching the server on and off Starting up and operation System already installed gt Press the On Off button see figure 13 on page 64 The server is switched on performs a system test and boots the operating system Switching the server off The power on indicator lights up green item 5 in figure 13 on page 64 gt Shut down the operating system properly The server is switched off automatically and goes into standby mode The power on indicator lights up orange If the operating system does not switch the server off automatically press the On Off button for at least four seconds and or send a corresponding control signal Other On Off options Besides the On Off button the server can be switched ON and OFF in the following ways Timer controlled switch on off Using the ServerView Operations Manager or iRMC S2 you can configure that the server is switched on off controlled by timer Ring indicator The server is switched on by an internal or external modem Wake up On LAN WOL The server is switched on by a command via the LAN Magic Packet
100. unit into the empty slot until it clicks into place Make sure that the new power supply unit engages correctly in the i mounting location and is locked in position This is the only way to prevent the power supply unit from sliding out of its mountings and being damaged during transportation RX600 S5 Operating Manual 95 Hot plug components CSS components gt Thread the cable through the cable clamp see figure 11 on page 60 gt Pull the cable clamp tight to secure the power cord gt Connect the newly installed power supply unit to the mains If everything is functioning correctly the green LEDs 1 and 3 see Indicators on the hot plug power supply units on page 73 at the rear of the power supply unit will now light up 96 Operating Manual RX600 S5 CSS components Hot plug components 8 1 2 Hot plug fans The server comes with four hot plug fans eight fans only in a redundant configuration Each fan is mounted in a fan module that is accessible from the top when opening the server A possible fan failure is reported by the CSS indicator lighting up on the front and rear of the server as well as by the indicator on the fan module in question The fan failure is also displayed on the ServerView Local Service Display see the Customer Self Service CSS manual on the ServerView Suite DVD 2 Identifying the defective CSS component gt Open the server see Opening Closing the server on page 134 Th
101. unity of Personal Computer issued by JEITA the Japan Electronics and Information Technology Industries Association Technology controlled by the Foreign Exchange and Foreign Trade Control Law of Japan Documents produced by Fujitsu may contain technology controlled by the Foreign Exchange and Foreign Trade Control Law of Japan Documents which contain such technology should not be exported from Japan or transferred to non residents of Japan without first obtaining authorization in accordance with the above law Harmonic Current Standards This product conforms to harmonic current standard JIS C 61000 3 2 Only for the Japanese market About SATA hard disk drives The SATA version of this server supports hard disk drives with SATA BC SATA storage interfaces Please note that the usage and operation conditions differ depending on the type of hard disk drive used Please refer to the following internet address for further information on the usage and operation conditions of each available type of hard disk drive http primeserverfujitsu com primergy harddisk Operating Manual RX600 S5 Only for the Japanese market Although described in this manual some sections do not apply to the Japanese market These options and routines include CSS Customer Self Service USB Flash Module UFM Replacing the lithium battery RX600 S5 Operating Manual Operating Manual RX600 S5 Contents 1 PERCE Li
102. vironmental protection Important information All batteries containing pollutants are marked with a symbol a crossed out garbage can They are also marked with the chemical symbol for the heavy metal that causes them to be categorized as containing pollutants Cd Cadmium Hg Mercury Pb Lead Labels on plastic casing parts Please avoid sticking your own labels on plastic parts wherever possible since this makes it difficult to recycle them Returns recycling and disposal Please handle returns recycling and disposal in accordance with local regulations The device must not be disposed of with domestic waste This device is labeled in compliance with European directive 2002 96 EC on waste electrical and electronic equipment WEEE This directive sets the framework for returning and recycling used HE equipment and is valid across the EU When returning your used device please use the return and collection systems available to you Further information can be found at http ts fujitsu com recycling Details regarding the return and recycling of devices and consumables within Europe can also be found in the Returning used devices manual via your local Fujitsu branch or from our recycling center in Paderborn Fujitsu Technology Solutions Recycling Center D 33106 Paderborn Tel 49 5251 525 1410 Fax 49 5251 525 32 1410 40 Operating Manual RX600 S5 4 Hardware installation CAUTION e Follow the safety in
103. w Local Service Display 15 67 ServerView Operations Manager 19 supported functions 19 ServerView Remote Management 21 service 20 service LAN connector 18 SFP transceiver module installation 129 removal 126 start up configuring the server 78 switching on the server 75 support 20 146 Operating Manual RX600 S5 Index support bracket 47 switch off time defining 76 switch on time defining 76 switching the server on off 75 system board features 15 system information 64 T target group 11 technical data 22 ambient conditions 24 time incorrect 88 tips 85 transport damage 42 transporting the server 37 troubleshooting 85 U unpacking server 42 USB connector 63 USB connectors 54 using cable clamps 60 V video connector 63 voltage 55 voltage range 16 RX600 S5 Operating Manual 147 Index 148 Operating Manual RX600 S5
104. y friendly product design and development This product has been designed in accordance with the Fujitsu standard for environmentally friendly product design and development This means that key factors such as durability selection and labeling of materials emissions packaging ease of dismantling and recycling have been taken into account This saves resources and thus reduces the harm done to the environment Further information can be found at http ts fujitsu com products standard_servers index html for the EMEA market http primeserver fujitsu com primergy concept for the Japanese market Energy saving information Devices that do not need to be constantly switched on should be switched off until they are needed as well as during long breaks and after completion of work Packaging information This packaging information doesn t apply to the Japanese market Do not throw away the packaging You may need it later for transporting the system If possible the equipment should only be transported in its original packaging Information on handling consumables Please dispose of printer consumables and batteries in accordance with the applicable national regulations In accordance with EU directives batteries must not be disposed of with unsorted domestic waste They can be returned free of charge to the manufacturer dealer or an authorized agent for recycling or disposal RX600 S5 Operating Manual 39 En
105. your data from unauthorized access For example you can assign passwords for users and administrators By combining these options you can achieve optimum protection for your system A detailed description of the Security menu and how to assign passwords can be found in the BIOS Setup documentation on the ServerView Suite DVD 2 RX600 S5 Operating Manual 83 BIOS Setup security functions Property and data protection 84 Operating Manual RX600 S5 7 Troubleshooting and tips CAUTION Follow the safety instructions in the Safety notes and regulations manual or 24 Ci and in chapter Important information on page 27 If a fault occurs attempt to resolve it using the measures described inthis chapter inthe documentation for the connected devices inthe help systems of the software used If you fail to correct the problem proceed as follows gt Make alist of the steps performed and the circumstances that led to the fault Also make a list of any error messages that were displayed gt Switch off the server gt Contact our customer service team 7 1 Power on indicator remains unlit The power on indicator remains dark after you switch on your device Power cable incorrectly connected gt Make sure that the power cable s is are correctly connected to the server and the grounded power outlet s Power supply overloaded gt Disconnect the server power plug s from the grounded