Home
Frigidaire PLHV42P8CC User's Manual
Contents
1. exhaust duct Female end shall be 4 1 2 below finished ceiling and securely fastened to joists Do not use duct smaller than the transition 5 Install 1 2 electrical conduit in location marked on template and extend length 6 S from ceiling Install drywall around duct and conduit then refinish ceiling Installation Appliance Installation Note two people may be required for proper installation 7 Install transition to top of hood if removed for shipping Snap damper into transition foam tape up with firm pressure at either end Mark onto exterior of transition the V location of the damper within See Figure 6 Note Duct screws can ONLY go below this line 8 Adjust chimney mounting structure to S dimension as determined in Step 1 page 5 Use 2 screws per attachment leg Do not fasten to ceiling now 9 Set chimney mounting structure on top of hood canopy Attach nuts loosely See Figure 7 and 8 10 Fit duct piece on transition so that top end is 5 1 2 below top of chimney structure male end up 11 Remove chimney structure from hood canopy 12 Install Ducting Fasten duct to transition with screws and tape per code Loosely fasten starter collar included flush to top of duct Note screws must not hamper the damper see 8 above for screw location Loosely fasten starter collar included flush to bottom of duct 13 To install Chimney Structure to ceiling use a 10mm or adjustable wrench or fl
2. Diameter of Transition 8 Diameter of exhaust Duct required 8 Note All dimensions are shown in inches Dimensions are given from base of hood to ceiling and include clearance required for installation Considerations before installing Hood 1 Forthe most efficient air flow exhaust use a straight run or as few elbows as possible CAUTION Vent unit to outside of building only If allowed in your area use metallic flex ducting only to connect rigid duct directly to transitions COLD WEATHER installations should have an additional backdraft damper installed to minimize backward cold air flow and a nonmetallic thermal break to minimize conduction of outside temperatures as part of the ductwork The damper should be on the cold air side of the thermal break The break should be as close as possible to where the ducting enters the heated portion of the house Hood installation height above cooktop is specified in Figure 2 Be sure that your hood model fits your installation ooo 1 1 Installation Tools required for installation Screw driver pozidrive n 2 torx 10 and 20 Allen spanner 4mm Shifting spanner 10mm pipe wrench Electric drill with twist bit 10 mm K Kitchen Height C Counter Height 36 standard P Height of Hood Bottom above counter not less than 30 A Canopy Height Hood height your installation S Chimney Structur
3. Q Electrolux OWNER S GUIDE Range Hood PLHV42P8CC PLHV42P8CC P N 316137229 Pub No 5995392114 a _ c Contents 2 Contents Product Registrations een e e 2 Important Safety INStrUCTIONS 3 Installati n OOO OOOO 4 8 Use and Care iia is 9 Hood Cleaning 10 Lights 2 2 E EE 10 Product Registration Thank you for choosing this appliance The information contained within this Owner s Guide will instruct you on howto properly operate and care for your range hood Please read through the information contained in your literature pack to learn Register your Product more about your new appliance The self addressed PRODUCT REGISTRATION CARD should be filled in completely signed and returned Record Your Model and Serial Numbers to the Frigidaire Canada Record inthe space provided belowthe model and serial numbers found on the serial plate located on the right hand side of the range hood Model Number 2 20 Serial Number This Owner s Guide contains general operating instructions for your range hood and feature information for several models Yourrange hood may nothave all the described features Note The instructions appearing inthis Owner s Guide not meant to cover every possible co
4. at head screwdriver Drill pilot holes into ceiling Attach mounting structure to joists with the 4 lag screws provided Keep 1 2 conduit inside structure See Figure 3 14 To fasten the canopy use a 10mm or adjustable wrench Affix nuts to top of canopy Figure 7 Do nottighten Raise canopy up to chimney structure and twist in place See Figure 8 Tighten nuts securely 15 Ducting for all units There should be no more than 1 gap between canopy ducting and house ducting Adjust starting collar over both ducts Tighten collar Fasten duct with screws and tape per code Make final angular adjustment to unit at ceiling if necessary then securely tighten 4 ceiling lag screws if not already tightened E Installation Wiring to Power Supply WARNING ELECTRICAL GROUNDING INSTRUCTIONS THIS APPLIANCE IS FITTED WITH AN ELECTRICAL JUNCTION BOX WITH 3 WIRES ONE OF WHICH GREEN YELLOW SERVES TO GROUND THE APPLIANCE TO PROTECT YOU AGAINST ELECTRIC SHOCK THE 77 Join the two bottom sections of the chimeny covers to cover the chimney Installation Chimney cover Figure 12 25 26 structure using 6 screws 3 each side see the plan diagram for joining the two sections Figure 12 Slide down the bottom section of the covers in its seat so that it completely covers the motor compartment and electrical connection box Figure 12 Apply the 2 tabs supplied to coverthe f
5. e Height your installation S H A 36 std Y Figure 2 Pre Installations Calculations see Figure 2 1 a Select a hood preference height P see Figure 2 that is comfortable for the user not less than 30 b Calculate Hood height your installation H see Figure 2 K C P c Confirm that H is within the range of min to max H found for your hood If not adjust your installation Calculate Chimney structure height 5 use formulas in Figure 2 and check dimensions of your hood Save this calculation for use later in the installation Preparation of Mounting Surface Installing supports above ceiling drywall Note Take into consideration the hood depth your hood could be much deeper than the cooktop 2 Mark center lines of cooktop or range on ceiling above Use centerlines marked on ceiling to position the mounting template Note location of hood front side and mounting holes indicated on template Remove and save template Cut and remove ceiling drywall Install suitable length 2 x 4 lumber between joists to provide chimney mounting points as shown in Fig 4 and 5 Use template for dimensions and required clearance Make sure to affix the added lumber firmly and level Consult a professional if you have difficulties or your installation is unique Consult template and Figures 3 4 5 Note the weight of the appliance see Table Install an 8
6. ished by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities c When cutting or drilling into wall or ceiling do not damage electrical wiring and other hidden utilities d Ducted fans must always be vented to the outdoors WARNING TO REDUCE THE RISK OF FIRE USE ONLY METAL DUCTWORK WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK DO NOT USE THIS FAN WITH ANY SOLID STATE SPEED CONTROL DEVICE AWARNING Electrical Shock Hazard Can result in serious injury or death Disconnect appliance from electric power before servicing If equipped the fluorescent light bulb contains small amounts of mercury which must be recycled or disposed of according to Local State and Federal Codes ts Installation FOR RESIDENTIAL USE ONLY NOT TO BE INSTALLED OVER GAS GRILLS PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING INSTALLATION MUST COMPLY WITH ALL LOCAL CODES IMPORTANT Save these Instructions for the Local Electrical Inspector s use INSTALLER Please leave these Instructions with this unit for the owner OWNER Please retain these instructions for future reference Safety Warning Turn off power circuit at the service entrance and lock out Dimensions Table 1 min 33 13 16 max 49 1 16 panel before wiring this appliance Requirement 120 V AC 60 Hz 15 or 20 A Weight 86 pounds
7. ixing points of the bottom flue CAUTION THE BOTTOM FLUE TABS ARE THE NARROWER AND SHALLOWER ONES The wider and deeper tabs are those used for the top flue and must be cut to size Figure 13 Attention Tabs must be fixed using the double sided adhesive tape supplied two segments each tab should be used Cut the e tape into 8 segments then remove the protection covering from both Sides and apply the segments close to the screws that fix the chimney flues to the structure NOTE Do not overtighten and deform metal 27 Turnthe main power on again atthe central electrical panel and check for correct hood operation Make sure to leave this manual for the home owner Figure 13 cr READ THE INSTRUCTIONS CAREFULLY BEFORE USING THE HOOD Use and Care Control Pad Functions Motor OFF button Figure 14 27 2 p ON button and motor suction For satisfactory use of your hood become familiar with the various functions of the Suction power 2 LED this led is ON when suction power 2 is selected power selection button 1 2 3 hood as described below Suction power 3 LED this led is ON when suction power 3 is selected 7 TR Light OFF button Light ON button Suction power 1 LED this led is ON when suction power 1 1 selected Intensive Suction power LED this led is ON when the intensive suction power is selected Intensive Suction power button this suction
8. ndition and situation that may occur Common sense and caution must be practiced when installing operating and maintaining any appliance Important Safety Instructions READ AND SAVE THESE INSTRUCTIONS Take care when using cleaning agents or detergents Suitable for use in household cooking area CAUTION To reduce risk of fire and to properly exhaust air be sure to duct air outside Do not vent exhaust air into spaces within walls or ceilings or into attics crawl spaces or garages CAUTION For General Ventilating Use Only Do Not Use To Exhaust Hazardous Or Explosive Materials And Vapors WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING a Use this unit only in the manner intended by the manufacturer If you have questions contact the manufacturer b Before servicing or cleaning unit switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel WARNING TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE Neverleave surface units unattended at high settings Boilovers cause smoking and greasy spillovers that may ignite Heat oils slowly on low or medium settings Always turn hood ON when cooking at high heat or when flambeing food i e Crepes Suzette Cherries Jubilee Pepperc
9. orn Beef Flambee Clean ventilating fans frequently Grease should not be allowed to accumulate on fan or filter Use proper pan size Always use cookware appropriate for the size of the surface element WARNING TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE OBSERVE THE FOLLOWING a SMOTHER FLAMES with a close fitting lid cookie sheet or metal tray then turn off the burner BE CAREFUL TO PREVENT BURNS If the flames do not go out immediately EVACUATE AND CALL THE FIRE DEPARTMENT b NEVER PICK UP A FLAMING PAN You may be burned DO NOT USE WATER including wet dishcloths or towels a violent steam explosion will result d Use an extinguisher ONLY if You know you have a Class ABC extinguisher and you already know how to operate it The fire is small and contained in the area where it started The fire department is being called You can fight the fire with your back to an exit WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING a Installation work and electrical wiring must be done by qualified person s in accordance with all applicable codes and standards including fire rated construction b Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipmentto prevent back drafting Followthe heating equipment manufacturer s guideline and safety standards such as those publ
10. power will function for 10 mins then the hood set again the preselected speed Grease Filter Saturation LED The Suction power 2 LED in Figure 12 is marked with an F This LED will flash to remind you when the grease filter needs to be cleaned after 40 hours use Followthe instructions for cleaning filters in this booklet Once the grease filters have been cleaned reset the reminder by pressing Motor OFF button for about 3 seconds until you hear the signal beep Operating Instructions The blower should be turned on for about 5 minutes before cooking in order to establish air currents upward through the hood Use the low speeds for normal use and the higher speeds for strong odors or fumes Minimize cross drafts which will reduce the effectiveness of the hood Hood Cleaning Figure 15 Lights replacement Turn off electric power to hood before removing light cover Lightcover Figure 16 Be sure lights are cool before cleaning the hood To Clean Filters The metal grease filters will last forever They are made of anodized aluminum It is recommended that the filters be washed at least once a month they can be washed by hand or in the dishwasher Drainwaterthrough edge holes and let each filter dry thoroughly before replacing it To Remove The Metal Grease Filters Disconnect the hood from electricity Push clips towards the rear and pull the filters downward Disengage each filter from a side and remo
11. ve it To Replace The Metal Grease Filters Reverse procedure To Clean Hood Surface For general care wipe the outside of the stainless steel white black or glass hood with sudsy water or household cleaners such as Fantastic or Formula 4099 rinse well and dry with clean soft cloth to avoid water marks Wipe and dry brushed stainless steel in the same direction as the grain Donotuse abrasive products To remove finger prints and give added shine use spray cleaners such as Stainless Steel Magic and Shimmer NOTE Turn blower and lights off Make sure the lights are cool If new lights do not operate be sure lights are inserted correctly before calling service e Remove the light cover using a little flat screwdriver or similar tool as a lever Removethe damaged light and replace with a new 12 Volt 20 Watt maximum halogen light made for a G 4 base Follow package directions and do nottouch new light with bare hands Reinstall the light cover snap into position 10