1. to firmly hold the needed adding a piece of wood as shown in FIG 2 or by removing screws f not make repairs before installing unit storm window while room air conditioner is being installed continued FIG 1 ee SASH SASH 19 MIN 19 MIN 1 2 MIN 11 2 MIN 4 EES pa BOARD THICKNESS AS REQUIRED ALONG ENTIRE STOOL FASTEN STORM WINDOW FRAME OR STORM WINDOW FRAME OR WITH TWO NAILS OR OTHER OBSTRUCTION OTHER OBSTRUCTION SCREWS P N 6612990 1162 4 CHECK FOR ANYTHING THAT COULD BLOCK AIRFLOW check area outside of window for things Tools Required such as shrubs trees or awnings Inside be sure a large flat blade screwdriver furniture drapes or blinds will not stop proper air flow tape measure adjustable wrench or pliers 5 Check the available electrical service power supply must pencil be the same as that shown on the unit serial nameplate Level Socket wrenches See Owner s Guide for serial plate location Power cord Phillips screwdriver is 48 long Be sure you have an outlet near All models have a 3 prong service plug to provide proper service and safe positive grouding Do not change plug in any way Do not use an adapter plug If your present wall Hardware in plastic bag outlet does not match your plug call a qualified electrician to make the needed change Washer Head ay Locking Screw For window panels i Avoid fire hazard or electric shock Do not use an extensioncord or a
2. Installation Instructions For Heavy Duty FAS Models and Median FAM Models Air Conditioners Please read ALL instructions before installing Two people are recommended to install this product If a new electrical outlet is required have the outlet installed by a qualified electrician before installing unit See 5 in Preliminary Instructions C a SAFETY LOCK AND following 3 4 LONG HEX HEAD SCREW WINDOW SASH SEAL Preliminary instructions Do the following before starting to install unit See illustrations WASHER HEAD LOCKING SCREW TOP ANGLE FOAM GASKET below FRAME Check dimenstions of your unit to determine model type ASTER T Heavy duty FAS Median FAM Unit Height 18 5 8 17 5 8 Unit Width 26 0 23 t SIDE RETAINER Min Window Opening 19 18 7 Min Window Width 31 26 1 2 Max Window Width 43 40 t7 A SEAL BOTTOM RAIL TO UNIT 1 Check window opening size the mounting parts furnished PS DEH a age 3 LOCKNUT WINDOW SUPPORT with this air conditioner are made to install in a wooden dit cies RACKET FLAT HEAD magr LT sill double hung window The standard parts are for BO SILLANGLE BRACKET window dimensions listed above Open sash to a minimum of 19 483mm FIG 1 3 Check your storm windows if you storm window 2 Check condition of window all wood parts of window frame does not allow the clearance required correct by must be in good shape and able
3. NER BACK INTO THE CABINET See FIG 5 2 Install Top Angle and Side Bracket 1 Attach foam gasket to top angle above holes as shown in FIG 6 2 Install top angle and side retainers to cabinet as shown in FIG 6 Assemble Window Filler Panels 1 Place cabinet on floor a bench or a table 2 Slide l section of window filler panel into side retainer on the side of the cabinet see Figures 7 8 Do both sides FIG 7 PLASTIC WINDOW FILLER FRAME RETAINER FIG 8 AIR CONDITIONE PLASTIC CABINET FRAME LOCKING SCREW WINDOW HOLE FILLER PANEL 3 Insert top and bottom legs of window filler panel Install Support frame into channel in the to angle and bottom rail Bracket Do both sides 4 Insert washer head locking screws 2 into holes in top leg of filler panel frame see Step 6 Do not totally tighten Allow leg to slide freely Screws will be tightened after Section 6 1 Hold each support bracket flush against outside of sill and tight to bottom of cabinet as shown below Mark brackets at top level of sill and remove Place Cabinet in Window 1 Open window and mark center of window stool i i i i i i 3 i i i 3 i 1 2 LONG SCREWS LEFT ND LOCKNUTS 2 Place cabinet in window with bottom stool angle firmly LOCKNUT scated over window stool as shown Bring window SILL ANGLE down tempora
4. d Sash Seal 1 Trim sash seal to fit window width insert into space between upper and lower sashes 2 Attach right angle safety lock as shown OW SASH SEAL ge LOCK 3 4 long hex ead screw Thru The Wall Installation NOTE Consult local building codes prior to installation or a qualified carpenter a Select Wall Location This air conditioner has a slide out chassis so that it can be installed through an outside wall as specified below Heavy Duty FAS Median FAM Max wall thickness 10 8 IMPORTANT Side louvers must never be blocked NOTE All parts needed for Thru The Wall Installation are provided except a wood frame shims and 10 wood screws 10 1 long minimum Select a wall surface that 1 does not support major structural loads such as the frame construction at ends of windows and under truss bearing points etc 2 does not have plumbing or wiring inside 3 is near existing electrical outlets or where another outlet can be installed 4 faces and is not blocked to the area to be cooled 5 allows unblocked airflow from rear sides and end outside of installed air conditioner 1 Prepare wail in frame construction including brick and stucco veneer Working from inside the room find wall stud nearest the center of area where air conditioner will be installed by sounding wall or by magnetically finding nails 2 Cut or knock out a hole on each side of center stud 3 Measure betwee
5. den frame 3 Position cabinet to achieve proper slope for water removal See FIG 1 below 5 Screw or nail cabinet wooden frame using shims if frame is oversized to eliminate distortion Remember S 4 PLUS to maintain proper slope as described in Step 3 TRIM THICKNESS SEE PARA 5 FIG 1 5 16 TO 3 8 LEVEL 4 Secure bottom rail to wood frame with two large wood screws 1 2 5 cm long using the two holes in the bottom 6 Install chassis into cabinet by following all steps in of the channel resting on frame See FIG 2 following Step 8 of Window Mounting continued OPTIONAL Caulking and installation of trim on interior wall may be done You can buy wood from your local lumber or hardware supply On the outside caulk openings around top and sides of cabinet and all sides of wood sleeve to the opening NOTE See Step 7 Item 3 of Window Mounting Instructions for bottom rail seal location Masonry Construction 1 Cut or build a wall opening in the masonry wall similar to the frame construction refer to Step 2 of Thru the Wall Installation for a wall thickness greater than 8 1 2 2 Secure cabinet in place using masonry nails or the right masonry anchor screws Another way to do this is to build an in between frame of 2x4 s as shown in the Step 2 Prepare Wall illustrations but make it double framed on either side and install between masonry wall opening and cabinet Frame must be securely anchored
6. n adaptor plug Do not remove any prong from the power cord 3 4 Long Hex Head Screw Grounding type wall receptacle 7D Do not under anh circumustances cut remove or bypass the 1 2 Long Screw and locknut grounding ack 3 4 Long Flat p Vv cord Head Bolt and ower supply cor with 3 prong yood Locknut plug and current detection device Sill Angle Bracket 6 Carefully unpack air conditioner remove all packing material Protect floor or carpet from damage Two CS Long hex head people should be used to move and install unit pistes POLOA for op angle side retainer 5 16 Long Window Mounting a Remove Chassis 1 Pull down front panel and remove filter See FIG 1 2 Lift front upwards and place to one side GE aS A i ae 3 Locate the four front screws and remove These screws will be needed to re install the front later See FIG 2 4 Pry away front from cabinet sides as per photo see FIG 3 5 Gently lift front off unit and place to one side See FIG A 6 Removeshippingcrewsfrom top of unitanddsoon theside by the base if installed 7 Hold the cabinet while pulling on the base handle and carefully remove the unit 8 Add two foam inserts to holes in top of cabinet where shipping screws were removed from Os Ga 9 9 Your unit may come with internal packaging THIS PACKAGING MUST BE REMOVED PRIOR TO INSTALLING THE AIR CONDITIO
7. n inside edges of every other stud as shown in FIG 1 FIG 1 3 3 8 MIN 8 6 cm Carefully measure and cut an opening with the following dimensions depending on your model See FIGS 1and 2 WIDTH X inside model width plus twice the thickness of framing material used HEIGHT Y inside model height plus twice the thickness of framing material used Heavy Duty FAS Median FAM Inside Frame Height 1878 47 9cm 18 45 7cm Inside Frame Width 2684 67 9cm 2378 60 6cm FIG 2 4 Build a wooden frame with the INSIDE dimensions of your model listed above Measure twice remember Frame depth should be the same as wail thickness Fill in the space from the opening to the studs with wood spacers as shown 5 Nail framd to spacers to spacers with front flush with dry wall NOTE If wall thickness is 8 1 2 or more add aluminum flashing over bottom of frame opening to assure no water R FIG 2 can enter area between inner and outer wall Th ZR 1 LONG WOOD SCREW T Refer to Step 4 of Window Mounting for assembly of support brackets A wooden strip nailed to the outside wall should be used in conjunction with sill support angle brackets ALUMINUM FLASHING OVER BOTTOM OF FRAME Res 81 2 a Prepare and Install Cabinet 1 Slide chassis from cabinet Refer back to Step 1 of Window Mounting 2 Place cabinet into opening with bottom rail resting firmly on bottom board of woo
8. rily behind top angle to hold cabinet in BRACKET TPR place 4 FLAT HEAD BOLT rn STOOL 2 EACH REQ D FOR EACH oo SUPPORT BRACKET ae STOOL 2 Asscmble sill angle bracket to support brackets at the eae marked position as shown Hand tighten but allow for any changes later 3 Shift cabinet left or right as needed to line up center 3 Install support brackets with sill angle brackets of cabinet on center line marked on stool attached to correct hole in bottom of cabinet as shown 4 Fasten cabinet to window stool with 2 screws into holes You may wish to pre drill pilot holes 4 Tighten all 6 bolts securely 5 Add bottom rail seal over screws to window stool Ss LN 2 long screws and focknuts Bottom Rail Seal aaa a ey 3 4 jong HEX HEAD SCREW Extend Window Filler Install Chassis into Panels Cabinet and Install Front to Unit 1 Lift air conditioner and carefully slide into cabinet leaving 6 protruding 2 PRONG DO not push on controls OR finned coils 3 Be sure chassis is firmly seated towards rear of cabinet Installation of front is the reverse of removal outlined in Section 1 1 Carefully raise window to expose filler panel locking screws Loosen screws so filler panels slide easily E 2 Extend panels to fill window opening completely Tighten locking screws on top 3 Close window behind top angle Install Window Lock a an
9. to masonry wall opening This way gives very good louver clearance on either side of cabinet 3 Install a linted to support masonry wall above cabinet Existing holes in cabinet can be used and or additions holes can be drilled to fasten cabinet at various positions Be sure that side louver clearance is in accordance with Step 1above 4 Install exterior cabient suppport brackets as shawn in Step 2 of Thru the Wall Installation Caulk or flash if neede to provide a wether tight seal around top and sides of cabinet 5 To complete installation apply wood trim molding around room side projection of cabinet