Frigidaire FHWC3040MS Product Specifications Sheet

image

Contents

1. Round Duct requires use of 7 Round Transition Duct included and can only be vented vertically e To provide efficient performance length of vent system and number of elbows should be kept to minimum Flexible vent greatly reduces oerformance and is NOT recommended e Use 3 1 4 x10 rectangular metal vent only rigid metal vent recommended plastic or metal foil vent NOT recommended e For cold weather installation additional backdraft damper and thermal break should be installed Thermal break will minimize conduction of outside temperatures as part of the vent system with damper on cold air side of break as close as possible to where vent system enters heated portion of house e Refer to Product Installation Guide on web for detailed vent system oreparation instructions Note For planning purposes only Refer to Product Installation Guide on the web at frigidaire com for detailed instructions Optional Accessories e Charcoal Filter PN 5304486303 e Duct Free Kit Single Pack PN 5304455849 e Duct Free Kit 8 Pack PN DFKIT308PK e Damper Kit 6 Pack PN DAMPKIT6PK e 7 Round Damper Kit Single Pack PN 5304455851 UL us Accessories information available on the web at frigidaire com Specifications subject to change 2014 Electrolux Home Products Inc
2. Connected Load kW Rating 120 Volts 23 kW For use on adequately wired 120V dedicated circuit having 2 wire service with a separate ground wire Appliance must be grounded for safe operation e Amps 120 Volts 18 Amps e Always consult local and national electric codes Check local building codes for installation requirements as they may vary per locale e Makeup air systems may be required by local building codes when using ventilation systems greater than specified CFM of air movement Specified CFM varies per locale e Connect vent hood with copper wire only For installation pre wired with aluminum wiring refer to Product Installation Guide on web for correct wiring procedure e Locate vent hood away from strong draft areas such as windows doors or strong heating vents e Minimum 24 30 installation height allowed from bottom of hood canopy to cooking surface minimum 66 height suggested from top of hood to floor e When installing vent hood under cabinets with recessed bottoms two 2 wide filler strips required with length and thickness determined by recess dimensions FRIGIDAIRE USA 10200 David Taylor Drive Charlotte NC 28262 1 800 FRIGIDAIRE e frigidaire com CANADA 5855 Terry Fox Way Mississauga ON L5V 3E4 1 800 265 8352 frigidaire ca FHWC3040M 08 14 Minimum 66 height suggested from top of Wall hood to floor ean duct requires use of transition duct incl
3. FRIGIDAIRE ia eTe N m 01010 FHWC3040MS Signature Features Halogen Lighting For bright illumination of the cooktop surface Convertible Exhaust System Our convertible hoods allow you to select between external or recirculating exhaust Washable Filters Dishwasher safe for easy cleaning The aluminum filter provides strength and durability not found in foam filters Nonstick Coating The nonstick surface of the underside of the range hood allows for quick and easy removal of grease and soot 30 Under Cabinet Features Nominal Width Installation Type Style Controls Air Discharge Air Delivery CFM Blower Type Sound Level dBA Fan Speeds Cooktop Light s Dishwasher Safe Filter s Exhaust Duct Duct Required Optional Accessories Charcoal Filter Duct Free Kit Single Pack Duct Free Kit 8 Pack Damper Kit 6 Pack 7 Round Damper Kit Single Pack Specifications Product Dimensions Height Width Depth Voltage Rating Connected Load kW Rating 120 Volts Amps 120 Volts Shipping Weight Approx Sones Rating 0 Under Cabinet Hidden Mechanical Push Button Vertical or Horizontal 300 Fan 68 2 3 2 Halogen 50W Included Yes Convertible 7 Round or 3 1 4 x 10 PN 5304486303 PN 5304455849 PN DFKITSO8PK PN DAMPKIT6PK PN 5304455851 4 15 16 30 19 3 4 120V 60HzZ 15A 25 Ls 24 Lbs 7 7 1 Ventilation is c
4. onvertible to be either ducted outside or recirculated inside requiring no ducting 2 For use on adequately wired 120V dedicated circuit having 2 wire service with a separate ground wire Appliance must be grounded for safe operation NOTE Always consult local and national electric codes Check local building codes for installation requirements as they may vary per locale Refer to Product Installation Guide for detailed installation instructions on the web at frigidaire com Specifications subject to change Available in Stainless S frigidaire com FRIGIDAIRE SS 30 Minimum 24 30 height allowed from bottom of hood canopy to cooking surface 36 base Cabinet height to floor Top or rear power 31 4 x 10 Rectangular supply locations duct location rear 7 Round or 31 4 x 10 rectangular duct location top 48 6 a eee 9 3 4 b Under Cabinet Hood Specifications e Product Shipping Weight Approx 24 Lbs e Under Cabinet Installation can be ducted vertically or horizontally e Ventilation system can exhaust air outside either vertically through roof or horizontally through wall Refer to Ducting Option Specifications for outside ventilation If ducting outside is not possible the system can be alternately set to recirculate air inside requiring use of recirculating kit included with hood e Sones Rating 7 7 e Voltage Rating 120V 60 Hz 15 Amps e
5. uded Overhead Hood FHWC3040MS 30 Under Cabinet Exhaust Options Vent hood can be vertically or horizontally ducted outside using round or rectangular duct or recirculated inside with no ducting required For detailed duct preparation and installation specifications refer to installation instructions on web Outside Vertical 7 Round Duct Cabinet Bottom Filler strip mounting screw holes 4 7 2 dia lt 83 HA for aa ound _ ict pn S 114 Electrical access hole in cabinet bottom Wood filler strips recessed cabinet bottoms only Outside Vertical 3 14 x 10 Rectangular Duct Cabinet Bottom Filler strip mounting screw holes 4 Rear oe uc Wall cutout e 8 514 514 dia Electrical access hole in cabinet bottom Wood filler strips recessed cabinet bottoms only Outside Horizontal 31 4 x 10 Rectangular Duct Cabinet Front Filler strips ae EO k T Sata ne i rake a 1 4 dia mounting SCrEWS Bil un 514 te Rwin Horizontal si access hole duct cutout in wall 8 in wall Ducting Option Specifications e Vent system MUST terminate outside through roof or wall do NOT terminate into attic or other enclosed area e Exhaust Duct Required 3 1 4 x10 rectangular with 35 maximum vent length or 7 round with 50 maximum vent length Refer to Product Installation Guide on web for calculations needed to determine total duct length e Installation of 7