1. 2A through 6A next page for left side mounting View A Follow STEPS 2B through 6B next page for right side mounting View B View B Right hinge Step 2A Mount the Side Bracket to the left side of the wall opening The Side Bracket must be plumb vertical Secure with four 8 x 11 4 pan head screws NOTE Hinge tabs must point upward Mounting the Side Bracket Step 4A Close the door Draw a temporary horizontal reference line on the wall adjacent to the center of the latch mounting hole Latch Draw mounting Reference hole in door Line on wall Step 6A Slide the bracket upward and tighten the mounting screws Installing Latch Bracket Step 3A Install door onto the Side Bracket Be sure that the access door has engaged the three tabs and the door is against the side mounting bracket Mount the Door on the Side Bracket Step 5A Attach the latch bracket to the opening aligning the bottom of the bracket with the reference line Use two 18 x 11 4 screws Do not tighten y Reference Line w Latch Bracket Installation Latch mechanism NOTE The latch mechanism should already be factory mounted This assembly is shown for reference The latch arm is adjustable to provide a secure rattle free installation Install the filter Access Panel ai Latch Arm D fo Latch Mechanism Orientation markings Side View Front View Mounting Latch Step 2B M
2. a FRIEDRICH VPRG4 Installation Instructions VERT I PAK Return Air Grille Access Panel For Vert l Pak A Series Units only Please read these instructions completely before attempting installation NOTE These instructions apply to Vert l Pak Series units only Refer to Chassis Installation Operation Manual for additional information Parts not Included in this Kit Parts Included in this Kit VPRG4 Return Air Grille Access Panel 25 x 20 Filter 58 Tall x 29 Wide 5 32 Allen wrench for latch 2x Mounting Bracket left and right mechanism operation Mounting Screws Frame and sheetrock the access hole to 27 wide and 55 4 tall The bottom of the opening should be at the same level as the floor or subbase The chassis must fit thru this opening The chassis is 23 s wide and 32 4 or 47 tall consult chassis specifications for actual dimensions Filter mounts on Side Bracket inside of door 25 x 20 Nom Filter field supplied VPRG4 Return Air Grille Access Panel 920 134 04 2 10 a FRIEDRICH VPRG4 Installation Instructions VERT I PAK Return Air Grille Access Panel For Vert l Pak A Series Units only Please read these instructions completely before attempting installation NOTE These instructions apply to Vert l Pak Series units only Refer to Chassis Installation Operation Manual for additional information Parts not Included in this Kit Parts Include
3. d in this Kit VPRG4 Return Air Grille Access Panel 25 x 20 Filter 58 Tall x 29 Wide 5 32 Allen wrench for latch 2x Mounting Bracket left and right mechanism operation Mounting Screws Frame and sheetrock the access hole to 27 wide and 55 4 tall The bottom of the opening should be at the same level as the floor or subbase The chassis must fit thru this opening The chassis is 23 s wide and 32 4 or 47 tall consult chassis specifications for actual dimensions Filter mounts on Side Bracket inside of door 25 x 20 Nom Filter field supplied VPRG4 Return Air Grille Access Panel 920 134 04 2 10 Step 1 Determine the orientation of the door ViewA The VPRG4 Kit comes with two mounting hinges Left hinge One mounts to the left side of the opening and locates the return air openings at the lower portion of the door View A The other mounts the hinge to the right side of the opening and locates the return air openings at the upper portion of the door View B This provides an option for the direction that the door will open More importantly it can aid in sound attenuation by locating the return air openings away from the evaporator opening on the unit NOTE For maximum sound attentuation it is recommended that the left hand bracket View A be used for VEA VHA24 models and the right hand bracket View B be used for VEA VHAOY 12 and 18 models Follow STEPS
4. ount the Side Bracket to the right side of the wall opening The Side Bracket must be plumb vertical Secure with four 8 x 11 4 pan head screws NOTE Hinge tabs must point upward M Mounting the Side Bracket Step 4B Close the door Draw a temporary horizontal reference line on the wall adjacent to the center of the latch mounting hole A Draw Latch Reference mounting Line on wall hole in door Step 6B Slide the bracket downward and tighten the mounting screws Installing Latch Bracket Step 3B Install door onto the Side Bracket Be sure that the access door has engaged the three tabs and the door is against the side mounting bracket Mount the Door on the Side Bracket Step 5B Attach the latch bracket to the opening aligning the bottom of Reference the bracket with the Line reference line Use two 18 x 11 4 screws 3 Do not tighten Latch Bracket Installation Latch mechanism NOTE The latch mechanism should already be factory mounted This assembly is shown for reference The latch arm is adjustable to provide a secure rattle free installation Install the filter Access Panel Latch Arm Ny ih Latch Mechanism Orientation markings Side View Front View Mounting Latch
Download Pdf Manuals
Related Search
Related Contents
Livestream Studio Surface Go User Manual 取扱説明書 - OS Engines Betriebsanleitung Hubantriebe LMBM — FORTRAN Subroutines for Large-Scale USER MANUAL Optimus 16-132 User's Manual Dali, Lijiang et montagnes sacrées du Kawa ステフ取扱説明書「検査者の手引」より 仕事で使う道具が、すっきり収納できる。 快適装備 Copyright © All rights reserved.
Failed to retrieve file