Home

Fisher & Paykel DD60S 7 User's Manual

image

Contents

1. Inlet hose 1250 mm p Power cord excl plug 1650 mm Power cord excl plug 1650 mm Venting hose 1525 mm Venting hose 1925 mm Cr EO e Integrated models with e Integrated models with remote NZ AU only remote NZ AU only 9 TALL HEIGHT DESIGNER amp INTEGRATED MODELS FOR 480 mm CAVITY ONLY ATTACH CAVITY BRACKET The enclosed cavity bracket is fitted before installation in order to conceal the gap at the top of the cavity left after installation Ensure the cavity panel bracket is positioned so that the F arrow is pointing towards the front of the chassis Firmly push the bracket so that the prongs engage with the top tabs and it clicks into place Important Ensure the prongs have not been driven down into the chassis as this will damage the lid below Ensure the top trim seal is facing forward after attaching the bracket 14 NOW CHOOSE WHICH INSTALLATION METHOD a or b IS MORE SUITABLE FOR YOUR CABINETRY RECOMMENDED METHOD a SECURE WITHOUT DRAWER REMOVAL FRAMELESS CABINETRY ONLY ATTACH SIDE MOUNTING BRACKETS INTEGRATED MODELS WITH REMOTE NZ AU ONLY ATTACH VENTING HOSE Clip all four side mounting brackets into their slots using a flat bladed screwdriver Ensure they re securely fitted before sliding product into cavity Check that the fitted elbow is rotated left or right depending on the direction of the routing then e
2. BADGE CONTROLS DRAINAGE OPTION CONNECT TO WATER amp ELECTRICITY FINAL CHECKLIST TROUBLESHOOTING SAFETY AND WARNINGS ALL MODELS A WARNING Electrical shock hazard Before installing the dishwasher remove the house fuse or open the circuit breaker This appliance must be earthed In the event of a malfunction or breakdown earthing will reduce the risk of electric shock by providing a path of least resistance for electric current This appliance is equipped with a cord having an equipment earthing conductor and an earthing plug The plug must be plugged into an appropriate outlet that is installed and earthed in accordance with all local codes and ordinances WARNING Improper connection of the equipment earthing conductor can result in a risk of electric shock Check with a qualified electrician or service representative if you are in doubt as to whether the appliance is properly earthed Do not modify the power supply plug provided with the appliance if it will not fit the outlet have a proper outlet installed by a qualified electrician Do not use an extension cord adapter plug or multiple outlet box Failure to follow this advice may result in electrical shock or death A WARNING Cut hazard Take care panel edges are sharp Failure to use caution could result in injury or cuts A WARNING Fitting integrated front panels requires access to electrical service areas This work must
3. REMOTE NZ AU ONLY ATTACH VENTING HOSE Check that the fitted elbow is rotated left or right depending on the direction of the routing then ensure the venting hose is securely attached to it 0 ALTERNATIVE METHOD b SECURE BY DRAWER REMOVAL 16 19 PULL THROUGH HOSES amp MOVE INTO THE CAVITY only a vent either through same cabinet or adjacent cabinet as per step 7b or 7c J Vent Hose Integrated models with remote NZAU Tu TH 3 As you push product in pull through hoses and cord ensuring they don t get kinked or twisted Important If product cannot be pushed in far enough pull out again and rearrange hoses and cord Do not use excessive force as doing so may squash the hoses and lead to incorrect operation SECURE THE DRAWER TO THE CABINETRY v The product has three Product may pairs of fixing points move Mark chassis position on cavity Ensure the sound insulation is repositioned correctly To prevent kinked hoses we recommend rotating the drawer anti clockwise and resting it on its side after removal two pairs of formed brackets on either side of the chassis use 16 mm screws a pair of fixing holes either side on the bottom use 38 mm fixing crews amp washers Press the release tabs in on either side and push back to release drawer from runners Push drawer runners back in 00 REFIT THE DRAWER
4. REMOVAL DRAWER REMOVAL RECOMMENDED ALTERNATIVE METHOD a METHOD b 1 FOLLOW STEPS FOLLOW STEPS FOR THE FOR THE EXTERNAL EXTERNAL VENTING KIT VENTING KIT INSTALL THE FRONT PANEL CHOOSE aad d OPTION CONNECT TO WATER amp ELECTRICITY FINAL CHECKLIST TROUBLESHOOTING Integrated with badge control DD60SHI7 PARTS SUPPLIED PRODUCT amp CABINETRY DIMENSIONS STANDARD HEIGHT CUSTOM FRONT PANEL CALCULATIONS CAVITY PREPARATION MAXIMUM DISTANCE OF HOSES amp CORD FROM CHASSIS EDGE SECURE WITHOUT SECURE BY DRAWER REMOVAL DRAWER REMOVAL RECOMMENDED ALTERNATIVE METHOD a METHOD b INSTALL THE FRONT PANEL amp BADGE CONTROLS CHOOSE DRAINAGE OPTION CONNECT TO WATER amp ELECTRICITY FINAL CHECKLIST TROUBLESHOOTING DD60SC H TX7 DD60SC H TW7 DD60SC H TM7 PARTS SUPPLIED PRODUCT amp CABINETRY DIMENSIONS TALL HEIGHT CAVITY PREPARATION MAXIMUM DISTANCE OF HOSES amp CORD FROM CHASSIS EDGE SECURE WITHOUT SECURE BY DRAWER REMOVAL DRAWER REMOVAL RECOMMENDED ALTERNATIVE METHOD a METHOD b a CHOOSE DRAINAGE OPTION CONNECT TO WATER amp ELECTRICITY FINAL CHECKLIST TROUBLESHOOTING TALL HEIGHT SINGLE MODELS ONLY AVAILABLE IN NZ AU ONLY AVAILABLE IN GB IE Designer Integrated with remote control Integrated with badge control DD60SDF H TX7 DD60SDFTM7 PARTS SUPPLIED PRODUCT amp CABINETR
5. adjacent to the dishwasher cavity EE 220 240 VAC min 4 8 A tape must be applied 0 mm Water Connection Recommended COLD Maximum 60 C 34 BSP GB20 to suit flat washer These marks indicate formed bracket screw locations if securing by drawer removal Water Pressure Water softener models Max 1 MPa 145 psi Min 0 1 MPa 14 5 psi Services can be located either side Important of the dishwasher Models without water Adjacent cabinetry i softener must not extend Max 1 MPa 145 psi above cavity base Min 0 03 MPa 4 3 psi min 200 mm H INTEGRATED MODELS WITH REMOTE NZ AU ONLY PREPARATION FOR EXTERNAL VENTING THROUGH SAME CABINET H Services can be located External Venting kit 1 either side of dishwasher _ feed Shelf cutouts max 5 mm VENT HOSE Zc H INTEGRATED MODELS WITH REMOTE NZ AU ONLY PREPARATION FOR EXTERNAL VENTING THROUGH ADJACENT CABINET The 260 mm services hole should be enlarged to accomodate the g60mm zs 4 extra venting hose by cutting out some material from External Venting kit 1 Services can be located the bottom corner Shelf cutouts either side of dishwasher VENT HOSE amp SERVICES WG max 5mm NS SS LS ue MAXIMUM DISTANCE OF HOSES amp CORD FROM CHASSIS EDGE Left hand side Right hand side Drain hose 2000 mm Drain hose 1800 mm Inlet hose 1650
6. below then complete with external venting kit the equation installed ventilation gap HEIGHT OF PANEL min 2 mm Note when the top of the dishwasher has to be lower than the adjacent cabinetry min 2 mm ventilation gap with the panel can be increased in height external venting kit installed E b INTEGRATED MODELS WITH BADGE GB IE ONLY CUSTOM FRONT PANEL CALCULATIONS amp b d i FRONT PANEL SPECIFICATIONS 16 20 mm panel thickness Adequately sealed to withstand moisture 50 C 80 Maximum weight of panel 9 kg zl The following calculations assume the top of the panel is aligned with the top of the adjacent cabinetry min 2 mm min 2 mm B WIDTH OF THE PANEL Measure A the width between adjacent door drawer fronts and write it in the first box below then complete the equation WIDTH OF PANEL min 2mm clearance to adjacent cabinet WIDTH OF PANEL front min 2 mm min 596 mm ales HEIGHT OF THE PANEL min 8 mm ventilation gap Measure B and write it in the first box below then complete the equation ventilation gap HEIGHT OF PANEL min 8 mm Note when the top of the dishwasher has to be lower than the adjacent cabinetry the panel can be increased in height min 8 mm ventilation 0 0 CAVITY PREPARATION Important The power outlet must be located in a cabinet
7. drawer excl handle 556 545 5453 F depth of front panel excl handle 29 18 16 20 G height of chassis 410 410 410 H depth of handle n a 41 n a 1 height of front panel 394 398 408 J height of ventilation gap below front panel 7 8 min 2 K height from top of handle to top of front panel n a 64 n a Tincludes 2mm high bracket slots Includes cavity bracket Assuming front panel thickness of 18 mm Jo41uo02 obpog 4Recommended for a 2 mm ventilation gap below panel if cavity height is 412mm Recommended 2 mm ventilation gap below panel 215521 4 599 582 553 556 29 454 438 A n a Jaubisaq A M N 599 571 553 545 18 454 41 470 64 TALL HEIGHT MODELS 454 454 599 599 574 571 553 553 5453 5453 16 20 16 20 454 454 4525 min 442 min 2 min 8 AADD 08 Jouo2 ajoway A M lt 599 5713 553 5453 16 20 454 n a 476 min 2 n a AJAD 08 Jo4juo2 abppg o9 5713 553 5453 16 20 454 min 470 min 8 5 CABINETRY DIMENSIONS Cabinetry dimensions mm STANDARD HEIGHT MODELS TALL HEIGHT MODELS amp amp amp amp 9 z z o 3 3 Zi 3 Bi Q E gre Spe Q b 3 2 898 3gm 38m E 8 288 Boss S388 8333 2 558 2 2988 S988 sza S998 L inside
8. INSTALLATION INSTRUCTIONS DishDrawer dishwasher DD60OS 7 amp DD6OST 7 models NZ AU GB IE Fisher amp Paykel 590200C 12 11 1 FOLLOW THE INSTALLATION SEQUENCE RELEVANT TO YOUR MODEL Classic DD60SC H X7 DD60SC H W7 DD60SC H B7 DD60SCM7 PARTS SUPPLIED PRODUCT amp CABINETRY DIMENSIONS STANDARD HEIGHT CAVITY PREPARATION MAXIMUM DISTANCE OF HOSES amp CORD FROM CHASSIS EDGE SECURE WITHOUT SECURE BY DRAWER REMOVAL DRAWER REMOVAL RECOMMENDED ALTERNATIVE METHOD a METHOD b D CHOOSE DRAINAGE OPTION CONNECT TO WATER amp ELECTRICITY FINAL CHECKLIST TROUBLESHOOTING STANDARD HEIGHT SINGLE MODELS Designer ooo DD60SDF H X7 DD60SDFM7 PARTS SUPPLIED PRODUCT amp CABINETRY DIMENSIONS STANDARD HEIGHT CAVITY PREPARATION MAXIMUM DISTANCE OF HOSES amp CORD FROM CHASSIS EDGE SECURE WITHOUT SECURE BY DRAWER REMOVAL DRAWER REMOVAL RECOMMENDED ALTERNATIVE METHOD a METHOD b a CHOOSE PRAMAS OPTION CONNECT TO WATER amp ELECTRICITY FINAL CHECKLIST TROUBLESHOOTING ONLY AVAILABLE IN NZ AU ONLY AVAILABLE IN GB IE Integrated with remote control DD60SI7 PARTS SUPPLIED EXTERNAL VENTING KIT PRODUCT amp CABINETRY DIMENSIONS STANDARD HEIGHT CUSTOM FRONT PANEL CALCULATIONS CAVITY PREPARATION amp EXTERNAL VENTING MAXIMUM DISTANCE OF HOSES amp CORD FROM CHASSIS EDGE SECURE WITHOUT SECURE BY DRAWER
9. ONTO THE RUNNERS Ensure the drawer e ta is now rotated SSS 1 the releas Dts bs 7 clockwise back Pa sides 100 P ly QO pem ey c INTEGRATED MODELS WITH REMOTE AU ONLY SECURE THE EXTERNAL VENT Before refitting the drawer ensure the hoses are not 5 p twisted and the latches at the rear of each drawer runner are facing forward eg LJ A A Ce 2 r m T After routing the vent hose R through and out the hole lt PU cutout attach and secure the EE vent by tightening the four screws provided ALSE both sides are reset fully Ensure the release tabs on INTEGRATED MODELS WITH REMOTE NZ AU ONLY INSTALLING THE FRONT PANEL 18 REMOVE BRACKET FROM PRODUCT Electrical Shock Hazard Before continuing ensure that the product is disconnected from the power supply Failure to follow this warning may result in electrical shock injury or fire Repeat for the other drawer A WARNING Electrical Shock Hazard To earth the panel bracket connect the earth wire from the product to one of the tabs Any custom metal component e g handle that extends past the rubber seal must be earthed too Failure to follow these warnings may result in electrical shock injury or fire 23 ATTACH PANEL TO PANEL BRACKET There must be at leas
10. Y DIMENSIONS TALL HEIGHT CAVITY PREPARATION MAXIMUM DISTANCE OF HOSES amp CORD FROM CHASSIS EDGE ATTACH CAVITY BRACKET SECURE WITHOUT SECURE BY DRAWER REMOVAL DRAWER REMOVAL RECOMMENDED ALTERNATIVE METHOD a METHOD b CHOOSE DRAINAGE OPTION CONNECT TO WATER amp ELECTRICITY FINAL CHECKLIST TROUBLESHOOTING DD6OSTI7 PARTS SUPPLIED EXTERNAL VENTING KIT PRODUCT amp CABINETRY DIMENSIONS TALL HEIGHT CUSTOM FRONT PANEL CALCULATIONS CAVITY PREPARATION amp EXTERNAL VENTING MAXIMUM DISTANCE OF amp CORD FROM CHASSIS EDGE 480mm CAVITY 480 mm CAVITY ONLY ATTACH CAVITY BRACKET 456mm CAVITY SECURE WITHOUT SECURE BY DRAWER REMOVAL DRAWER REMOVAL RECOMMENDED ALTERNATIVE METHOD a METHOD b FOLLOW STEPS FOLLOW STEPS FOR THE FOR THE EXTERNAL EXTERNAL VENTING KIT VENTING KIT INSTALL THE FRONT PANEL DRAINAGE OPTION CONNECT TO WATER amp ELECTRICITY FINAL CHECKLIST TROUBLESHOOTING DD60SHTI7 PARTS SUPPLIED PRODUCT amp CABINETRY DIMENSIONS TALL HEIGHT CUSTOM FRONT PANEL CALCULATIONS CAVITY PREPARATION MAXIMUM DISTANCE OF HOSES amp CORD FROM CHASSIS EDGE m 456mm CAVITY 480mm CAVITY 480 mm CAVITY ONLY ATTACH CAVITY BRACKET SECURE WITHOUT SECURE BY DRAWER REMOVAL DRAWER REMOVAL RECOMMENDED ALTERNATIVE METHOD a METHOD b L INSTALL THE FRONT PANEL amp
11. be performed and certified by a qualified electrical service technician Electrical Shock Hazard WARNING To reduce the risk of electrical shock fire or injury to persons the installer must ensure that the dishwasher is completely enclosed at the time of installation Before fitting the front panels and connecting the integrated badges where present the installer must ensure that the dishwasher is disconnected from the power supply After installing the front panel the installer must ensure that the following components are electrically earthed the panel bracket the integrated badge where present and any custom metal component e g handle that extends past the rubber seal Failure to follow these warnings may result in electrical shock injury or fire IMPORTANT SAFETY INSTRUCTIONS Installation of this dishwasher requires basic mechanical and electrical skills Be sure to leave these Instructions with the Customer Installation must comply with your local building and electricity regulations At the completion of the dishwasher installation the Installer must perform the Final Checklist Remove all packaging materials supplied with the dishwasher This dishwasher is manufactured for indoor use only Ensure all water connections are turned OFF It is the responsibility of the plumber and electrician to ensure that each installation complies with all Codes and Regulations The dishwasher MUST be installed to allow for
12. de for further information and instructions No program indicator lights up when the drawer is opened Ensure power is connected and is switched on If it is and still no indicator ligths up see the Preference options section of the Quick start guide An option called Open drawer auto power on may need to be turned on Water around water supply and drainage connections Check connections existing plumbing and hoses for leaks Check rubber washer and hose clamp are correctly fitted a If product is tipping Ensure the product is secured to the cabinetry If front panels are misaligned Check and relevel product Check the cabinetry is square For Integrated models check and adjust front panel alignment if necessary Drawer doesn t close properly Ensure nothing is obstructing the drawer from closing properly eg sound insulation hoses or drawer latches faproblem occurs consult the Troubleshooting section of the User guide If after checking these points you still need assistance please refer to the Service amp Warranty book for warranty details and your nearest Authorised Service Centre or contact us through our website listed below Important SAVE THESE INSTRUCTIONS The models shown in this document may not be available in all markets and are subject to change at any time For current details about model and specification availability in your country please visit our local website listed at the end of th
13. future removal from the enclosure if service is required The switched power outlet must be outside the dishwasher cavity so that it is accessible after installation Care should be taken when the appliance is installed or removed to reduce the likelihood of damage to the power supply cord and hoses If the dishwasher is to be relocated from one installation to another it must be kept upright to avoid damage from water spillage Make sure only new hoses are used for connection supplied with the dishwasher Old hoses should not be reused Failure to install the dishwasher correctly could invalidate any warranty or liability claims If the product is installed in a motor vehicle boat or similar mobile facility you must bring the vehicle boat or mobile facility containing the product to the service shop at your expense or pay the service technician s travel to the location of the product SAVE THESE INSTRUCTIONS IMPORTANT SAFETY INSTRUCTIONS Read these instructions completely and carefully Ensure the product is not plugged in Installation of custom panels requires basic mechanical and electrical skills Installation must comply with your local building and electricity regulations Failure to install the custom panels correctly could invalidate any warranty or liability claims SAVE THESE INSTRUCTIONS PARTS SUPPLIED ALL MODELS gt W Drain hose Drain hose Wire clip 1 support 1 joiner 1 for securin Drain ho
14. h i hose through drain hose support to required height ln 2 Ley f 2 n d HIGHLOOP min 150 mm Important Do not connect the drain hose to a waste disposal unit as this type of connection may CONNECT INLET HOSE TO COLD WATER p Tighten coupling with spanner Qo ges Ensure the x supplied rubber A washer is t fitted inside i 180 No leaks the coupling 2 material if necessary Do not shorten the inlet hose lead to a blockage in the drain hose Ensure drain hose is routed straight to joiner Remove excess drain hose 95 PLUG PRODUCT IN 5 s 0 S FINAL CHECKLIST OO lt OO ogo Check all parts are installed Ensure that all panels and parts thereof are secure and final electrical tests have been conducted in accordance with local electrical regulations Ensure product is level securely fastened to the cabinetry and opens and closes freely The drawer must be free to fully close with no resistance from the cabinetry Ensure inlet hose to water supply has supplied rubber washer fitted and that it s tightened a further half turn after seal contact Ensure any knockouts or plugs in drain connection have been drilled out and drain connection has been made The drain hose joiner must not support the weight of excess hose material Keep drain h
15. height of cavity min 412 min 412 412 n 41 2 456 480 456 456 480 480 M inside width of cavity 600 600 600 600 600 600 600 600 600 600 N inside depth of cavity min 560 min 560 min 560 min 560 min 560 min 560 min 560 min 560 min 560 min 560 Minimum clearances from adjacent cabinetry min 13 mm Anam In m Cavity height options allow you to match dishwasher with your cabinetry or companion products cean d ne clearance OE ee adjacent cupboard door Standard height models Tall height Classic models Tall height Designer models ea min dishwasher 412mm Tall height Integrated models You may choose to install Tall height Integrated models into either a 456 mm or a 480 mm high cavity Note the minimum height of the custom drawer front panel will also be different for these two options 2 pp RR o min 2 mm FRONT PANEL SPECIFICATIONS 16 20 mm panel thickness Adequately sealed to withstand moisture 50 80 RH Maximum weight of panel 9 kg The following calculations assume the of the panel is aligned with the top of the adjacent cabinetry A min 2 mm WIDTH OF THE PANEL Measure A the width between adjacent door drawer fronts and write it in the first box below then complete the equation WIDTH OF PANEL i WIDTH OF PANEL front min 2 mm min 596 mm OF PANEL HEIGHT OF THE PANEL min 2 mm ventilation gap Measure B and write it in the first box
16. is document or contact your local Fisher amp Paykel dealer www fisherpaykel co nz www fisherpaykel com au www fisherpaykel co uk www fisherpaykel ie www fisherpaykel eu
17. nsure the venting hose is securely attached to it 0 Fitted Elbow The mounting slots are in pairs one on each side diagonally across the product A bracket must match A slot and B bracket must match B slot 2a PULL THROUGH HOSES amp MOVE INTO THE CAVITY mi Vent Hose Integrated models with remote NZAU only un SD S vent either through same cabinet or adjacent cabinet as per step 7b or 7c As you push product in pull through hoses and cord ensuring they don t get kinked or twisted Important If product cannot be pushed in far enough pull out again and rearrange hoses and cord Do not use excessive force as doing so may squash the hoses and lead to incorrect operation fd SECURE THE DRAWER E Openthe 4 the grey rubber plug out of the trim moulding J Replace the grey rubber plug back into the trim moulding and ensure the trim seal is facing forward 7 Using a small Philips screwdriver screw through the trim p moulding securing the side mounting bracket Do not damage the rubber trimseal Repeat for all four brackets INTEGRATED MODELS WITH REMOTE NZ AU ONLY SECURE THE EXTERNAL VENT After routing the vent hose oa through and out the hole cutout attach and secure the vent by tightening the four Air screws provided flow o INTEGRATED MODELS WITH
18. ose as fully extended as possible to prevent sagging Any excess length of drain hose should be kept on the dishwasher side of the highloop If connecting the drain hose to the sink trap ensure the Highloop is a minimum 150 mm higher than the drain hose joiner Ensure any packaging or tape securing the racks is removed from the drawer Turn on the power and water supplies then open the drawer You should hear a beep and see a program indicator light up on the internal control panel Check the spray arm is in place and free to rotate Nas Add three cups of water into the drawer Press on the internal control panel until the indicator of the Rinse program lights up Close the drawer and press bil to start the program After the Rinse program has finished ensure the dishwasher has run and drained correctly Check water supply and drainage connection for leakage 27 TROUBLESHOOTING 2 Excessive water remaining above the filter plate after the rinse cycle Check for a kinked drain hose blocked waste connection highloop not properly installed drain hose not routed correctly or spray arm not in place No water supply This is displayed as a U1 fault see section If there is a fault in the User guide for how to recognise this fault on models without a display Check water is connected and turned on The dishwasher is beeping continuously There is a fault See section If there is a fault in the User gui
19. rtant Ensure the rubber seal Electrical Shock Hazard between the drawer Connect the integrated badge we earth wire to one of the two tabs a and panels IS kept in provided on the panel bracket lace To earth the panel bracket 2 p connect the earth wire from the product to the other tab Any custom metal component e g handle that extends past the rubber seal must be earthed too Failure to follow these warnings may result in electrical shock injury or fire down Important gap below the panel Push the panel in then up to locate With the front panel fitted insert an appropriately sized Philips screwdriver into the hole above the door pin and rotate the panel up or down to align the gaps in your cabinetry Repeat on the other side if necessary The panel has a maximum travel of 2 mm up or Ensure that you maintain a minimum of 8 mm ventilation When refitting the door pins ensure they are orientated as shown 3 THERE ARE TWO DIFFERENT PLUMBING AND DRAINAGE OPTIONS CHOOSE WHICH IS MORE SUITABLE Dishwasher and Standpipe 38 mm A If space is limited for fixing push hose through drain p hose support 9 to required height 750 882 5 mm N min R 200 mm 22 Supplied drain hose joiner 19 mm waste tee NE Dishwasher using sink trap with drain hose joiner n SS _ If space is limited N for fixing pus
20. se joiner Cavity bracket kit 1 supplied with Tall height Designer and Integrated models only Side mounting bracket kit A and B 2 OPTIONAL 1 for securing Drain hose joiner i Phillips 16mm screws 7 38 mm bottom fixing screws amp metal washers 2 If the Drain hose supplied is not long enough to reach your services you must use a Drain Hose Extension Kit P N 525798 which will extend the drain hose by 3 6m The kit is available from the nearest Fisher amp Paykel Authorised Service Centre or through our local website listed at the end of this document Rubber washer for inlet hose 1 comes already fitted Moisture protection tape 1 to prevent moisture damage ADDITIONAL PARTS SUPPLIED WITH INTEGRATED MODELS i External Venting kit 1 dee 1 Panel peng attached to screws 6 product supplied with Integrated models with remote NZ AU only Integrated rectangular badge 1 Satin chrome supplied supplied with Integrated models with badge GB IE only 4 PRODUCT DIMENSIONS Product dimensions STANDARD HEIGHT MODELS 8 z i Hi m a 5 A height of product incl front panel height 410 410 410 B overall width of product 599 599 599 overall depth of product excl handle 582 571 571 D depth of chassis to back of front panel 553 553 553 E maximum extension of
21. t 3 screws used each side Align bottom of panel with bottom of bracket Important Ensure the rubber seal between the drawer and panel is kept in place When refitting the door pins ensure they are orientated as shown INTEGRATED MODELS WITH REMOTE NZ AU ONLY INSTALLING THE FRONT PANEL 19 Goa ADJUST PANEL HEIGHT TO ALIGN THE CABINETRY GAPS With the front panel fitted insert an appropriately sized Philips screwdriver into the hole above the door pin and rotate the panel up or down to align the gaps in your cabinetry Repeat on the other side if necessary or 2mm The panel has a maximum travel of 2 mm up or down Important Ensure that you maintain a minimum of 2 mm ventilation gap below the panel i eee INTEGRATED MODELS WITH BADGE GB IE ONLY INSTALLING THE FRONT PANEL amp BADGE CONTROLS 20 6 DETERMINE BADGE CUTOUT LOCATION 2 REMOVE BRACKET amp DISCONNECT BADGE WARNING Electrical Shock Hazard ore continuing ensure that the product is nnected from the power supply Failure to follow this warning may result in electrical shock injury or fire 9 ATTACH PANEL TO PANEL BRACKET There must be at least 3 screws used each side Align bottom of panel with bottom of bracket INTEGRATED MODELS WITH BADGE GB IE ONLY INSTALLING THE FRONT PANEL amp BADGE CONTROLS 21 10 ATTACH PANEL TO PRODUCT Impo

Download Pdf Manuals

image

Related Search

Related Contents

APC NetShelter SX 42U  Mode d`emploi - Harmony Assistant Travailler une partie Pour isoler  Festool PD561438 Cordless Saw User Manual  SUPER MICRO Computer X9DRG-HF User's Manual  "取扱説明書"  IS-IP200-IRB/IS-IP220-IRB-30 User`s Manual  Préparation à mélange fouetté nutritif Formule 1  L`été, on reprend la plume  GPS M ultisport KeyM aze 300  - SatelliteTV4Boats  