Home

Fisher & Paykel CG903MLD User's Manual

image

Contents

1. 5 FINAL CHECKLIST FOU UU Uo o lt IU TO BE COMPLETED BY THE INSTALLER Have you installed the clamping brackets Have you allowed for adequate air supply to the product Have you used the supplied flexible hose and blue washer Have you leak tested all connections Is the regulator set to the correct working pressure Have you placed the supplied duplicate data plate on an adjacent surface Is the CookSurface earthed Check that the power supply cable is NOT touching the CookSurface OPERATION Do all burners ignite both individually and in combination Are the flames consistent and appropriately sized Have you demonstrated the basic operation to the customer Installer s name Installer s signature Installation company Date of installation LEAVE THESE INSTRUCTIONS WITH THE CUSTOMER www fisherpaykel co nz www fisherpaykel com au 599760A NZ AU 03 09
2. a view from below h Refit existing screw to secure into basepan gt a Fresh air from outside cabinetry 50 mm reverse the clamping For benchtops thicker than brackets as shown in Product and cabinetry dimensions mm overall height of product including dials pan supports overall width of product overall depth of product height of chassis below top of bench width of chassis depth of chassis depth of chassis including fitted elbow GTA TM ON oO Se overall width of routered recess width of cutout TZI overall depth of routered recess depth of cutout corner radius of cutout distance from edge of chassis to gas inlet on product corner radius of routered recess 2l x height of routered recess distance from top of bench to centre of gas inlet on product YNOZI TIWE0699 max 2 5 Z aIWE0699 856 480 480 905 865 535 494 max 10 64 20 max 2 5 Apply tape foam inside recess to stop silicone leaking underneath 7 a min 150 C rated TO REMOVE PRODUCT 7 REMOVE FROM PACKAGING ENSURE THERE IS ADEQUATE AIR SUPPLY The CookSurface requires adequate air supply to fully function The base of the CookSurface must have direct unrestricted ventilation to the room where the CookSurface is installed Do not ventilate the base area to an
3. Centre Customer Care or contact us through our website www fisherpaykel com Q PRODUCT amp CABINETRY DIMENSIONS G CLEARANCE DIMENSIONS Note Gas inlet connection is located in the back left corner The CookSurface requires adequate air supply to fully function The base of the CookSurface must have direct unrestricted ventilation to the room where the CookSurface is installed Do not ventilate the base area to an external area that can be at different air pressure to that of the burners You may ventilate from adjacent cupboards but ensure that the available air supply will not be restricted The ventilation area must be 500 x 50 mm or of an equivalent area If the 50 mm wide slot is not possible due to the width of the available toe recess increase the length of the slot so as to maintain an equivalent area of 250 cm An air intake grill is provided Ensure that the grill is not covered or obstructed Installation diagrams for illustration purposes only Q z Q O Product and cabinetry dimensions mm Nn Clearances mm 8 _8 a S o No oN w ne 28 22 mee Q S g2 Se Bo mo Pr vU A minimum clearance from left edge of product to nearest combustible surface 60 60 A overall height of product including retracted dials pan supports 96 96 B minimum clearance from right edge of product to nearest combustible surface
4. 80 80 B overall width of product 900 900 minimum clearance from rear edge of product to C overall depth of product 410 530 C nearest combustible surface 100 10 nearest non combustible surface 10 10 D height of chassis below top of bench 89 89 7 7 7 7 D minimum height of non combustible material when used on adjacent walls 150 150 E width of chassis 856 856 a minimum clearance from glass surface to F depth of chassis 384 480 rangehood 650 650 G depth of chassis including fitted elbow 424 480 E any other overhead exhaust fan 800 800 downward facing combustible surface 650 650 H overall width of cutout 865 865 downwards facing tiled or fire resistant surface 500 500 overall depth of cutout 390 494 minimum clearance below top of benchtop to J corner radius of cutout max 10 max 10 F combustible surface i 115 115 Fisher amp Paykel oven or nearest non combustible surface 100 100 K distance from tap Sf Bench to centret gas inlet on product 4 64 G cutout measuring 50 x 500 mm for air intake grill Ensure air can easily enter the area around the base of L distance from edge of chassis to gas inlet on product 20 20 the product from the room in which the product is installed Note Ensure there is an earthed power outlet within 900 mm of the centre rear of the product The supplied flexible Note CG903ML models only If benchtop thickness exceeds 50 mm additional cutout space will be required to hose must be used between the
5. Installation instructions IZONA CookSurface CG903ML amp CG903 MLD models Fisher amp Paykel innovative living Important SAVE THESE INSTRUCTIONS The models shown in this document may not be available in all markets and are subject to change at any time For current details about model and specification availability in your country please visit our local website listed at the end of this document or contact your local Fisher amp Paykel dealer CT SAFETY AND WARNINGS A WARNING Electrical shock hazard Disconnect appliance from main power supply before continuing Failure to do so could result in electrical shock or death A WARNING Cut hazard Take care panel edges are sharp Failure to use caution could result in injury or cuts Impor tant safe ety preca utions a Particular attention shall be given to the relevant requirements regarding ventilation Please make this information available to the person installing the appliance as it could reduce your installation costs This appliance is to be installed and connected to the electricity and gas supply only by an authorised person Installation must comply with your local building and local gas authority codes and electricity regulations a Failure to install the appliance correctly could invalidate any warranty or liability claims These appliances are registered in New Zealand at www ess govt nz and Australia with SAI Global at www saiglo
6. bal com This gas appliance is suitable for connection to natural gas only If in doubt refer to the local gas network operator or gas supplier to confirm gas type at installation site Before you install the appliance please make sure that the local distribution conditions nature of gas and pressure and the adjustment of the appliance are compatible For adjustment conditions for this appliance see Gas rate summary a suitable disconnection switch is incorporated in the permanent wiring mounted and positioned to comply with the local wiring rules and regulations A means of disconnection with at least a 3 mm air gap contact separation in all poles must be incorporated into the fixed wiring in accordance with the wiring rules unless the local wiring rules allow for alternative means the appliance is connected to a 220V 240V 50Hz 10 A power supply only and earthed via the power supply cable there is a power outlet within reach of the power supply cable 900 mm from the centre rear of the product This must be accessible after installation The power supply cable should not touch any metal parts if the power supply cable is damaged it is replaced only by the special cable Part no 531953 Flex Terminal Block Assy NZ AU obtainable from authorised Fisher amp Paykel Service Agents the supply connection point gas shut off valve is accessible after installation the benchtop is made of a heat resistant material the installa
7. external area that can be at different air pressure to that of the burners You may ventilate from adjacent cupboards but ensure that the available air supply will not be restricted The ventilation area must be 500 x 50 mm or of an equivalent area If the 50 mm wide slot is not possible due to the width of the available toe recess increase the length of the slot so as to maintain an equivalent area of 250 cm An air intake grill is provided Ensure that the grill is not covered or obstructed 9 FIT THE ELBOW amp FLEXIBLE HOSE LOWER GENTLY INTO THE CUTOUT A Important The flexible hose supplied must be used to enable servicing S Ensure there is enough flexible hose looped to allow for removing appliance for servicing i MW i 4 W A Q AD SECURE THE PRODUCT TO THE BENCHTOP 2 CONNECT TO THE GAS amp ELECTRICAL SUPPLY Aja view from below y x4 Al NG Ensure the blue washer is fitted N Cn For benchtops thicker than 50 mm reverse the clamping brackets as shown Refit existing Refit existing screw to secure screw to secure into basepan into basepan Fresh air from Fresh air from outside cabinetry outside cabinetry AL A Q 2 Test operation by 4 lighting all burners
8. product gas inlet and the connector on the wall which should be 650 750 mm above accomodate the fitted elbow the floor and towards the left hand end of the product It should be accessible with the product installed 4 PARTS SUPPLIED na 7 hose 1 5 GAS RATE SUMMARY All appliances are factory set for natural gas and are not currently convertable to LPG T e c pz e a Injector orifice mm Injector orifice mm Nominal rating MJ h Injector orifice mm MEDIUM NG 1 0 kPa Wok stand 1 Flexible Blue washer 1 Elbow 3 8 NPT 1 Nominal rating MJ h NG NG CG903ML amp 8 0 CG903MLD i i Nominal pressure with the two smaller burners on High N RAN gt gt gt Air intake grill 1 and screws 6 6 FLUSH MOUNTING INSTALLATION NOT RECOMMENDED A WARNING We do not recommend flush mounting and sealing as servicing requires the CookSurface to be removed from the benchtop The owner carries all risk for flush mounting the CookSurface The owner must ensure the CookSurface has been cut out from the benchtop before servicing can be carried out Fisher amp Paykel will not be liable for any costs associated with removing or replacing a flush mounted and or sealed in product nor for repairing any damage that may be incurred by doing this Top view H
9. tion complies with all the requirements of Australian and New Zealand Gas Installation Standards AS5601 NZS5261 including that the product has to be installed so that the surface temperature of any nearby combustible surface will not exceed 65 C above ambient See Clearance Dimensions When you install the appliance We do not recommend you flush mount or seal this appliance into the bench with silicone or glue Doing so will make future servicing difficult Fisher amp Paykel will not be liable for any costs associated with removing or replacing a sealed in appliance nor for repairing any damage that may be incurred by doing this Seal exposed bare edges of the cutout with an oil based paint or moisture proof polyurethane to prevent possible moisture creeping between the cooktop trim and the benchtop We do not recommend the use of a down draught extractor fan with the appliance as it may distort the flame pattern causing uneven heating and reduced cooking performance Where this appliance is installed in marine craft or in caravans it shall not be used as a space heater No combustible material or products should be placed on this appliance at any time Do not spray aerosols in the vicinity of this appliance while it is in operation If after following the instructions given the appliance cannot be adjusted to perform correctly please refer to the Service amp Warranty book for warranty details and your nearest Authorised Service

Download Pdf Manuals

image

Related Search

Related Contents

Helios Installation Manual - Starcom Systems  Das BCC-Handbuch für den Contester  EnerGenie EG-PDU-001 power distribution unit PDU  

Copyright © All rights reserved.