1. COOKSURFACE DIMENSIONS CG363MLDNGB1 CG363MLNGB1 DIMENSIONS INCHES MM CG363MLNGB1 CG363MLDNGB1 A Overall width of cooktop 35 900 35 900 B Overall depth of cooktop 16 410 20 530 C Height of chassis below top of counter 3 89 3 89 D Width of chassis 33 e 856 33e 856 E Depth of chassis 15 384 18 480 F Overall height of product including retracted dials pan supports 3 96 3 96 Product dimensions and specifications are listed as a guide only For complete installation instructions and specifications refer to the product Use amp Care Guide Installation Instructions available at www fisherpaykel com Fisher amp Paykel fisherpaykel com 1 888 936 7872 COOKSURFACE CABINET DIMENSIONS CG363MLDNGB1 CG363MLNGB1 Cutout dimensions Clearance and cabinetry dimensions Cutout measuring 2 x 20 50 x 500mm for air intake grill Ensure air can easily enter the area around the base of the product from the room in which the product is installed DIMENSIONS INCHES MM CG363MLNGB1 CG363MLDNGB1 A Overall depth of cutout 15 390 19 7 6 494 B Corner radius of cutout max 10 max 10 C Overall width of cutout 346 865 34 6 865 D Min clearance from left edge of product to nearest vertical surface 2 60 2 60 E Min vertical distance between coun
2. nd of the product It should be accessible with the product installed Product dimensions and specifications are listed as a guide only For complete installation instructions and specifications refer to the product Use amp Care Guide Installation Instructions available at www fisherpaykel com Fisher amp Paykel fisherpaykel com 1 888 936 7872
3. ter and cabinet extending above the counter 18 457 18 457 F Min distance between overhead cabinets installed to either side of product 36 915 36 915 G Min distance from front edge of counter to front edge of product 1 32 1 4 32 H Minimum clearance from rear edge of product to nearest combustible surface 1 4 32 y 13 nearest non combustible surface less than 1 32 less than 2 a3 I Minimum clearance from the glass surface to combustible surface centred 30 762 30 762 above the cooking surface J Min clearance below top of countertop to nearest combustible surface 4 115 4 115 Fisher amp Paykel oven or nearest non combustible surface 4 100 4 100 K Minimum clearance from right edge of product to nearest vertical surface 3 80 3 80 L Distance from top of counter to center of gas inlet on product 2 64 2 64 M Distance from edge of chassis to gas inlet on product CG363ML models only If countertop thickness exceeds 2 SO mm additional cutout space will be required Ya 20 a 20 to accomodate the fi tted elbow Note Ensure there is a grounded power outlet within 35 2 900 mm of the center rear of the product A suitable flexible hose must be used between the product gas inlet and the connector on the wall The connector should be 251 4 29 650 750mm above the floor and towards the left hand e

Download Pdf Manuals

image

Related Search

Related Contents

カタログPDFはこちら  Desfibrilador externo automático DDU  Bedienungsanleitung  Vacuum Pumps Common Problems and Troubleshooting  User Manual - TEWS TECHNOLOGIES  Lenoxx Air Module CBWMV User's Manual  Oneida Air Systems 2005c3HP User's Manual  OKI C9200dn Led Printer  Manual VZ9plus English_Deutsch.cdr  Einleitung Highlights der ELSA WINNER II  

Copyright © All rights reserved.
DMCA: DMCA_mwitty#outlook.com.