Home
Faber INCA PRO 30 RB User's Manual
Contents
1. TWO HANDS one to hold the filter so that it doesn t fall on cooktop and one to turn the knob by pulling the knob out and turning to the left Remove the entire bottom of the rangehood by pushing your thumbs into the side holes and pulling the sides free from the rangehood Remove the wiring box cover by removing the two screws from Disconnect the two red wires by removing the twist on wire connector control Remove the Internal Control Box by removing the the two phillips screws item A on the bottom of the rangehood Close the hole using the cap provided in the Remote Wall Control package using the two screws Remove the Electronic Board on the wiring box by removing the the two phillips screws red wires Electronic Board to be removed Insert the cable with four wires Brown Black Red and Green Ground Wire from the Remote Wall Control into the knockout hole of the rangehood Insert the 3 Remote Blower wires Black White and Green Ground Wire into the knockout hole of the rangehood Insert the power supply cable into the knockout hole of the rangehood h Connect the green ground wire from the power supply to the green ground screw Connect the green ground wire from the Remote Wall Control to the unused green ground screw Connect the green ground wire of the Remote Blower
2. EJ FABER REMOTE WALL CONTROL INSTALLATION INSTRUCTIONS WARNING To reduce the risk of fire electric shock and injury to persons the Remote Wall Control must be installed only with Faber range hood models INCA PRO 30 RB or INCA PRO 38 RB that are marked to indicate suitability with this product Other models cannot be used READ AND SAVE THESE INSTRUCTIONS The Installer must leave these instructions with the homeowner The homeowner must keep these instructions for future reference and for local electrical inspectors use A WARNING Risk of electrical shock Electrical wiring must be done by qualified personnel in accordance with all applicable codes and standards Turn off the power and lock out the service panel before installing wiring or servicing this product To prevent serious injury from electrical shock or damage to electrical components MAKE SURE POWER IS OFF This unit must be grounded A WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING a Installation Work And Electrical Wiring Must Be Done By Qualified Person s In accordance With All Applicable Codes and Standards Including Fire Rated Construction b When cutting or drilling into wall or ceiling do not damage electrical wiring and other hidden wires MAKE YOUR CUT OUTS A WARNING Cuta level 4 11 32 X 3 5 32 hole in to your desired location Route the electrical cable from the hood to the wall control locati
3. LINE IN REMOTE BLOWER M NY 436003417_verl 060627
4. on black wiring INSTALL THE REMOTE WALL CONTROL N YIG wiring A WARNING To reduce the risk of fire and electric shock do not use this control in an insulated wall e Remove the back metalic panel of the Remote Wall Control by removing the four screws Insert and fix a cable with four wires Brown Black Red and Green Ground Wire into the knockout hole of the back metalic panel Connect the green ground wire from the cable to the green ground screw Connect the red wire from the cable to the red Remote Wall Control wire with a twist on wire connector Connect the brown wire from the cable to the white black Remote Wall Control wire with a twist on wire connector Connect the black wire from the cable to the two black Remote Wall Control wires with a twist on wire connector e Replace the back metalic panel The twist on wire connector should be suitable for connecting multiple wires of different sizes together e Remove the faceplate from the Remote Wall Control by removing two screws e Position the remote control box in a hole so that both face plate mounting tabs are flush to the finished wall surface Fasten it to a wall stud using four screws not supplied e Reinstall the control faceplate ensuring not to pinch the wires white wiring brown wiring CONNECTION OF THE REMOTE WALL CONTROL TO THE RANGEHOOD To install the rangehood please refer to the hood installation instructions Remove the grease filters USING
5. to the unused green ground screw Connect the red wire from the Remote Wall Control with the red wire of Wiring Box with a twist on wire connector Connect the brown wire from the Remote Wall Control with the black wire of the Remote Blower cable with a twist on wire connector Connect the black wire from the Remote Wall Control with the black wire of the power supply cable with a twist on wire connector Connect together with a twist on wire connector the following wires violet rangehood wire white wire of the power supply cable white wire of the Remote Blower cable Replace the wiring box cover Tighten the screw securely Replace the bottom of the rangehood and reinsert the grease filters Reconnect the power from lamp o remote twist on white wiring connectors blower emol conduit violet wiring wall o from control lamp conduit Y G mE remote brown wiring wall control O Y G remote blower Q YIG supply power a o suppl red wiring cable black wiring PA Twist on wire connector should be suitable for connecting multiple wires of different sizes together PoE a q REMOTE CONTROL BLK WHY BRW i gt gt 1 SPEED CONTROL BLK BLK p RED RED VLT l Y G Q O71 LIGHT Ye __WIRING BOX WHT Y G BLK 120 Vac INCANDESCENT LAMPS
Download Pdf Manuals
Related Search
Related Contents
Sony ECM-C10 Operating Instructions CMCO Katalog 2015 "MC-720" Visor de reportes V5 Copyright © All rights reserved.
Failed to retrieve file