Home
Extron electronic 350MV User's Manual
Contents
1. ai gure 1 TLP 350MV Front Panel left and Front Panel with Bezel Removed to Show Recessed Buttons right Light sensor monitors the level of ambient light and adjusts the screen brightness and button backlighting 3 5 inch LCD screen provides a graphical user interface with a pressable touch screen display Speaker provides audible feedback Motion detector detects movement in front of the panel When no motion has been detected for a user defined period of time the unit goes into sleep mode which shuts down the screen display and inactivates all the buttons When motion is detected these functions are restored O 09O Eight backlit push buttons can be configured to perform user defined functions using the Extron Global Configurator software Encoder knob intended for volume control but it can be configured for other functions Two buttons and an LED are recessed behind the bezel Remove the bezel using the Extron removal tool inserted into the tabs on the bottom of the panel as shown in the figure at right Menu button activates the on screen menus for calibrating and setting the unit Reset button allows the unit to be reset in any of four different modes See the Reset Modes section on the back page of this setup guide Reset LED is visible only when the faceplate has been removed It lights as an indicator for the reset modes Remove Bezel at Tabs Ext
2. front panel a second time to open the calibration screen This screen adjusts the precision of the screen to the location of the finger touch Press the green button until it changes color Press and Hold Calibrate the next button When all four points have been calibrated Highlighted Box the screen reopens to the main setup screen Until Color Changes 4 Press Exit to close the on screen menus 5 Reattach the bezel Four clips two at the top and two at the bottom snap into place See the figure at the bottom of the first page Reset Modes The TLP 350 MV has four reset modes that can be initiated by pressing the Reset button Factory Firmware Mode 1 Hold the Reset button while applying power to reset the unit back to the base firmware shipped with the unit Run Stop Events Mode 3 Hold the Reset button until the reset LED blinks once 3 seconds then release and press Reset momentarily less than 1 second within 1 second This mode turns events on or off Reset All IP Settings Mode 4 Hold the Reset button until the reset LED blinks twice 6 seconds then release and press Reset momentarily less than 1 second within 1 second This mode resets the IP address subnet gateway port mapping and DHCP settings back to factory defaults The reset LED blinks 4 times in quick succession confirming the reset and turning events off If necessary reset the IP address using ARP and the MAC address Reset Factory Defaults
3. Mode 5 Hold the Reset button until the reset LED blinks 3 times 9 seconds then release and press Reset momentarily less than 1 second within 1 second This mode causes a reset to factory defaults for everything except firmware NOTE Refer the TLP 350MV User Guide available at www extron com for additional details Designing and Configuring the TLP 350MV Interface Producing the graphical user interface GUI for the TLP 350MV requires two steps You must first design the layout using the Extron GUI Configurator software This allows you to design buttons icons text and other objects and organize their layout on the screen Once the layout has been designed use the Extron Global Configurator software to assign functions to each of the buttons NOTE You must use Global Configurator 3 0 4 or a later version and GUI Configurator 1 1 or a later version to configure the TLP 350MV Both of these programs are on the DVD that is provided with the TouchLink Panel or can be downloaded free of charge to your PC from the Extron Web site www extron com For information about downloading and installing either program consult the TLP 350MV User Guide which can be downloaded from the Extron Web site To get started using either program refer the TLP 350MV User Guide Full instructions for the programs can be found in their help files which can be opened from the Help menu of the programs Extron USA West Extron USA East Extron Eur
4. TLP 350MV e Setup Guide Overview The Extron TLP 350MV is a wall mounted TouchLink Panel that provides simple and versatile configuration and control for a range of IP Link control systems Graphic and text objects are displayed on the screen These objects have system control functions associated with them and the Touchpanel allows you to control those functions Two BNC connectors allow the screen to be used to preview composite video or S video NOTE The RJ 45 output on the rear panel of the TLP 350MV must be connected to a network switch hub or router that is connected to an Ethernet LAN or the Internet An Extron IP Link controller must also be connected to the same network Suggested models include IPL T S series for example IPL T 4 IPL 250 IPL T CR48 or IPL T SFI244 This guide provides basic instructions for experienced installers to mount and perform initial configuration on the TLP 350MV Full instructions and reference material can be found in the TLP 350MV User Guide which is available on the Extron Web site www extron com TLP 350MV Front Panel Features T 2G 2a A 3 o aO eae D 5 slz 8189 388 16 0 3 8 8 82 388 38 3
5. en for leaving the menus NOTE Only the Main screen provides links to the Vol Time IP and Vid screens All other screens have a link to return to the Main screen After calibrating each group of settings return to the Main screen to access the next screen Setup Menu 1 Press the recessed Menu button on the front panel to activate the Sleep 00000 Sec top level menu screen The menu opens at the Main Setup Page 2 Touch an area of the screen to bring it into focus and use the Up and Down buttons or the volume control knob to adjust the value Some l options have a single button and toggle between Off and On when Backlight 075 the button is pressed Use the different menu pages to adjust the following options For more L details see the user guide Main shown at right Shows Power over Ethernet status and adjusts zerade A the Sleep timer Backlight Auto Backlight and LED Backlight functions Auto LED Motion Vol Adjusts the Master Click global button sounds and Sounds e on on on playback wav files volume settings Time Sets the correct time and date IP Sets the IP address and the subnet mask and enables or disables Dynamic Host Configuration Protocol Vid Provides a small video preview window and the controls to calibrate video contrast color brightness and tint TLP 350MV e Setup Guide Continued Calibration Screen 1 Press the recessed Menu button on the
6. er Supply section of the TLP 350MV User Guide NOTE If both a PoE power supply and a 12 VDC power supply are present the unit will draw power from the PoE power supply only Run video cables with to the mounting site Leave enough slack in the cables to connect them to the TLP 350MV Pull the cables through the mud ring Connect the cables as shown in the diagram below Plug the cables into the rear panel connectors of the TLP 350MV refer the TLP 350MV User Guide Secure the TLP 350MV to the mud ring using the two screws provided top center and bottom center Do not replace the bezel at this time You will need access to the recessed Menu and Reset buttons to configure the unit C yellow cable Video Y white cable T a ft BEE viD Y c 5 POWER VIDEO PREVIEW Olar Power over Ethernet PoE Power Supply Extrom le 4 ji PWR LAN OUT LAN IN T ARA A E AA AA A EE i l To TLP 350MV To Network Switch Using a UL Certified Junction Box 1 Locate a wall stud and mark the position where the junction box will be placed Use the size specifications provided by the manufacturer Wall Stud 2 Cuta hole in the wall To avoid making the hole too big cut inside the lines you marked in step 1 3 Test the fit by inserting the junction box into the hole in the Junction Box wall If necessary use a rasp
7. ope Extron Asia Extron Japan Extron China Extron Middle East Headquarters 800 633 9876 800 633 9876 800 3987 6673 800 7339 8766 81 3 3511 7655 400 883 1568 971 4 2991800 Inside USA Canada Only Inside USA Canada Only Inside Europe Only Inside Asia Only 81 3 3511 7656 FAX Inside China Only 971 4 2991880 FAX 68 1807 50 1 714 491 1500 1 919 863 1794 31 33 453 4040 65 6383 4400 86 21 3760 1568 RevA 1 714 491 1517 FAX 1 919 863 1797 FAX 31 33 453 4050 FAX 65 6383 4664 FAX 86 21 3760 1566 FAX 08 10 2010 Extron Electronics All Rights Reserved www extron com
8. or file to enlarge the hole 4 Insert the junction box into the hole in the wall Secure it to the stud using two screws or nails as appropriate The front edge of the junction box must be flush with the front surface of the wall f f S 2 5 Secure the wall adapter provided to the junction box using the es four screws provided 6 Connect a network switch to the LAN In port of the PoE power supply provided Run a second cable from the Pwr LAN Out port to the TLP 350MV mounting site see the figure on the previous page 7 Run video cables to the mounting site Leave enough slack in the cables to connect them to the TLP 350MV Pull the cables through the mud ring TLP 350MV Connect the cables as shown in the diagram at the bottom of the previous page 9 Secure the TLP 350MV to the wall adapter Two clips at the top and two at the bottom audibly click when the panel moves into place You should also use the two screws provided top center and bottom center 10 Do not replace the bezel at this time You will need access to recessed the Menu and Reset buttons to configure the unit Configuring the TLP 350MV Initial Setup Before use the TLP 350MV must be configured using the on screen menus There are five different screens Main Vol Time IP and Vid that can be selected by pressing the appropriate button at the edge of the Main screen There is also an Exit button at the bottom left corner of the scre
9. ron Removal Tool TLP 350MV Setup Guide Continued Mounting the TLP 350MV Decide where to mount the TLP 350MV and whether to use a 3 gang mud ring or a 3 gang UL certified junction box The mounting instructions are slightly different depending on your choice Using a Mud Ring 1 10 11 Use the template provided with the mud ring to mark ie Seah giadne ts the wall For the mud ring provided the hole must be 5 25 32 inches 14 68 cm wide x 3 7 8 inches 9 83 cm high Cut a hole in the wall To avoid making the hole too big cut inside the lines you marked Test the fit by inserting the mud ring into the hole in the wall If necessary use a rasp or file to enlarge the hole Insert the mud ring into the hole and use a screw driver to turn and tighten the locking arms until they clamp the mud ring to the mounting surface Do not overtighten Secure the wall adapter provided to the junction box using the four screws provided Mud Ring Use the Extron removal tool provided to separate the bezel from the TLP 350MV see figure on previous page TEE OOM Extron recommends using the provided Power over Ethernet PoE power supply Connect a network switch to the LAN In port and run a second cable from the Pwr LAN Out port to the Touch Panel mounting site see the figure below Bezel CAUTION Whether you use a PoE power supply or a 12 VDC power supply not provided you must read the caution in the Pow
Download Pdf Manuals
Related Search
Related Contents
ダウンロード Gentile GH-UMSEBシリ一ズ 取扱説明書 Ver-ー`。 BENDIX 03-K-3 User's Manual 862511 Descarga las reglas del juego RT55HD MV3 (En.Fr.De.Es)-1.ai Manual ServerView Virtual Samsung S3 4GB Black Benutzerhandbuch Copyright © All rights reserved.
Failed to retrieve file