1. terminal block The transformer side of the CPX 120 cover plate has a 7 connector terminal block Route the two wires from the amplifier through the cover plate hole to the transformer side The black negative a attaches to the COM terminal and the red postitive wire attaches to the desired terminal tap POO Nozi nstallation in a plenum rated environment requires a wire gauge of 12 AWG to 18 AWG Pull the speaker wires from the conduit if a conduit is used Strip 3 16 5 mm from the wire ends keep the wire end strands together by twisting them do not tin the wires and secure the wires to the appropriate taps on the terminal block s captive screw connectors as indicated on the tap label Use a small flat blade screwdriver to tighten the terminal block screws See the note below for wiring additional speakers Route the speaker wires from the second speaker through the cover plate hole to the transformer side and twist the black negative wires together and twist the red positive wires together before inserting them into the terminal block Additional speakers can be daisy chained this way Noli Be sure to observe the 70 V or 100 V system designation as indicated on the label Wiring two speakers in parallel requires that the maximum wire gauge not exceed 16 AWG Ina single speaker installation the wire gauge should not exceed 12 AWG When using flexible conduit insert the conduit into the cov
2. Extron FF 120T Flat Field Speaker User s Manual 1 Power down Power down all attached devices before proceeding 2 Suspended ceiling installation Remove the ceiling tile where the FF 120T speaker will be installed Cut out a 12 section of the tile from either end where the speaker will be installed as shown below End Section hs 12 Draw Lines 24 x 48 Ceiling Tile 24 x 24 Ceiling Tile 3 Remove the terminal cover plate Loosen the two screws do not remove on the top terminal cover plate and remove the cover plate e Ifa 70 V 100 V line distribution amplifier is being used such as the Extron XPA 2001 70V or XPA 2001 100V the cover plate is no longer needed since the included CPX 120 transformer cover plate will be installed in its place e f the 70 V 100 V line distribution system is not being installed retain the cover plate and proceed to step 6b 4 Routing cables through the CPX 120 cover plate The CPX 120 cover plates mount to the speakers with the transformer side down See the illustration below Flexible Flexible Conduit From AmP_ Conduit Adapter _ To Second Speaker ii Cable Clamp Adapter supplied Seismic Anchor Ring Top Terminal 7 Cover See the NOTES below Nou nstallation of conduit and conduit adapters should conform to all applicable building codes and local ordinances 68 1450 02 Rev A 07 09 5 Connecting wires to the CPX 120
3. er plate opening using an appropriate conduit adapter and secure the conduit to the plate as shown in the following illustration i Extron FF 120T User s Manual Black To Speaker Terminal Red To Speaker Terminal To Second Speaker Black Red From Amplifier 70V 100V When using plenum speaker wire without a conduit insert the wire through the cable clamp adapter included and secure the adapter to the cover plate e f a seismic support line is being used install the seismic anchor ring included between the conduit adapter and the CPX 120 cover plate as shown below e If the CPX 120 transformer cover plate is being installed proceed to step 6a otherwise proceed to step 6b 6a Connecting wires from the CPX 120 to the speaker Strip 3 16 5 mm from the ends of the two speaker wire leads and coming from the transformer Keep the wire strands together by twisting them do not tin the wires and secure the wires to the speaker s input terminals while observing the correct polarity Connect the red positive wire to the speaker terminal and connect the black negative wire to the speaker terminal as shown below Proceed to step 7 Seismic Anchor Ring Red Wire To CPX 120 transformer cover plate Black Wire Flat Field Speaker 6b Connecting wires from a low impedance amplifier to the speaker Route the wires from the amplifier to the speak
4. er using the same procedure for routing speaker wire and conduit if applicable through the cover plate as described in step 3 Strip 3 16 5 mm from the ends of the two speaker wire leads and coming from the amplifier Keep the wire strands together by twisting them do not tin the wires and secure the wires to the speaker s input terminals while observing the correct polarity Connect the red positive wire to the speaker terminal and connect the black negative wire to the speaker terminal depending on whether one or two speakers are being connected as shown below Red Wire To Amplifier Black Wire Red Wire To Amplifier To Second Speaker To Amplifier To Second Speaker Black Wire Two Speakers Extron FF 120T User s Manual Flat Field Speaker 7 Installing the speaker in the Anchor this end to a cel l ng Route the cable through SUADS SEGUT PONI the seismic anchor ring and bendout tab See the following illustration a Replace the cover plate and tighten the two cover screws A o Seismic AE N A Safety Bend Up Tab Cable b Install the included T rail crosspiece into the ceiling opening up against the cut tile c Set the speaker into place so that the edges are hidden by the support rails Nozi Repeated bending of the tab may cause it to break off 9 Power up After checking all soeaker connections power up the amplifier 8 Attaching the
5. ng kit NA AMOM ciiceataaes gece ceemenenteccetesdee ISTA 1A in carton International Safe Transit Association Regulatory compliance Safety ver vennsstunnrtnincnstocccccines NFPA90A NFPA70 UL Listed for use in plenum airspaces meets UL 2043 for heat and smoke release meets UL 1480 for commercial and professional audio systems Warranty cases ttece state 5 years parts and labor yg am A nominal levels are at 10 MoE Specifications are subject to change without notice Extron Asia Extron Japan Extron China Extron Middle East 800 7339 8766 81 3 3511 7655 400 883 1568 971 4 2991800 Inside Asia Only 81 3 3511 7656 FAX Inside China Only 971 4 2991880 FAX 65 6383 4400 86 21 3760 1568 65 6383 4664 FAX 86 21 3760 1566 FAX
6. seismic support lines If seismic support lines are being used connect a line through the seismic anchor ring on the top terminal cover plate and attach it to one of the center seismic bendout tabs the center tab is preferred located on either side the speaker as shown below Use a small screwdriver or similar tool to bend out the tab See the following illustration Noyi Observe all applicable building codes and local ordinances when installing the speaker User s Manual Application diagram Extron MIX 301 Three Channel Mixer 4 Wireless Microphone System Extron FF 120T Plenum Flat Field Ceiling Speakers lt Extron MPA 401 70V Extron VCM 100 AAP Volume Mute Controller in AAP 100 Frame Packaging FF 120T Setup Guide Ss s 3 hi m 0 wo We S 9 R lt urioO www extron com CPX 120 Transformer Cover Plates 2 Extron USA West Extron USA East Headquarters 800 633 9876 800 633 9876 Inside USA Canada Only Inside USA Canada Only 1 919 863 1794 1 714 491 1500 1 919 863 1797 FAX 1 714 491 1517 FAX Mini Power Amplifier Cable Clamp anchor Sheet Extron FF 120T Flat Field Speaker Speakers Ring Adapters Protective Bubble End Cap Bottom Cap Extron Europe 800 3987 6673 Inside Europe Only 31 33 453 4040 31 33 453 4050 FAX Specifications Speaker LV PG iiccasecvrsonicdaceelens 1 way f
7. ull range in ceiling speaker Frequency range seeceeeeeeees 68 Hz to 18 kHz 10 dB half space Power Capacity cece 16 W rms continuous pink noise 32 W rms continuous program Nominal Sensitivity cc00 86 dB SPL 1 watt 1 m half space Nominal coverage angle 170 conical coverage Nominal impedance 00 8 ohms per speaker IW Se rssicon 1 3 76 2 mm paper cone AID UT CONNECTION vsccuvenssnsdsbedeonteaues 1 8 mm Euro style captive screw terminal block 7 pole Tap settings 70 V IND ecstteccrnonstcenneucdates 16 W 8 W 4 W 2 W 1 W null bypass 8 ohms direct connection 100 V TD Ul vcsanvecsaecnccvennnsuins Null 16 W 8 W 4 W 2 W 1 W bypass 8 ohms direct connection PAG el Gb occ cannreceaeamccteesatantgaete 2 speakers 1 pair with 2 61 cm cross bars Temperature humidity Storage 40 to 158 F 40 to 70 C 10 to 90 noncondensing Operating 32 to 122 F 0 to 50 C 10 to 90 noncondensing POMONA TUNG assoc etee noose astiddeceea ees Drops into 2 x 2 61 cm x 61 cm or 2 x 4 61 cm x 122 cm suspended tile ceilings Enclosure type eseese Composite rectangular with metal grille Enclosure outer dimensions 3 25 H x 23 75 W x 11 75 D 8 3 cm H x 60 3 cm W x 29 9 cm D Product weight esesssssesseeeeeeeeeee Single 5 1 Ibs 2 3 kg Shipping WEIOM o ccreeetsvsin xestaceesian Pair 17 lbs 8 kg with mounti