Home
Euro-Pro FC251 User's Manual
Contents
1. 6 Do not use without all filters in place Note This vacuum cleaner is equipped with a plug and power cord that retract automatically If the cord or plug get damaged it must be replaced by a qualified technician Warning Hold the plug when rewinding the cord Do not allow the cord to whip when rewinding OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS Assembling Your Vacuum Cleaner Note Always remove the power plug from the wall outlet before assembling or removing accessories 1 Attaching the Flexible Hose into the Vacuum Connect the flexible hose into the air intake duct Push in until you hear a click indicating it is in its locked position To remove the flexible hose first remove the power nozzle cable from the socket then depress locking button and remove hose Connect the connecting power cord from the flexible hose to the power cord receptacle that is on the unit just below the air intake duct Air intake duct Power cord receptacle 2 Fitting the Telescopic Tube to the Curved Wand Hose Extension Push the extension tube into the curved wand hose extension as shown in the illustration below Ag gt Fes aiie 3 Extending the Chrome Telescopic Tube Push forward on the plastic button and pull the inner chrome tube outward w i Plastic Button 4 Fitting the Floor Brush to the Telescopic Tube Push the telescopic Extension Tube t
2. Dust Cup Filter TapCleaned 4 once a after each use month or and suction a rae does not return appears to 100 then reduced we suggest that the HEPA filter be TapCleaned vigorously until no more dust can be removed then rinsed under the faucet and allowed to dry for 24 hours before refitting into the vacuum Fig A This should be done once a month or when suction appears to be reduced Warning Allow 24 hours for drying before replacing in unit Important The suction hole must be open free of any obstructions at all times Otherwise the motor will overheat and could become damaged 7 Insert the dust cup cover and HEPA filter into the dust cup 8 Re install dust cup and cover into vacuum Close cover and re attach hose IMPORTANT Please note that there is a safety switch inside the vacuum where the dust cup Is inserted to prevent the unit from being run without a dust cup in place If the dust cup has not engaged this safety switch the vacuum will NOT operate Therefore ensure that the dust cup is inserted firmly into the vacuum when assembling Changing amp Cleaning the Post Motor Filter The post motor filter is a washable filter but should be replaced every three 3 to six 6 months depending on usage Never operate he vacuum without ALL the filters in place e Push the Power On Off button to the Off position and disconnect the power cord from the wall outlet OPERA
3. EURO PRO amp select OWNER S MANUAL Model FC251 120V 60Hz 12 Amps Bagless Cyclonic Canister Aspirateur Cyclonique Sans Sac For information or assistance USA EURO PRO Operating LLC 94 Main Mill Street Door 16 Plattsburgh NY 12901 Tel 800 798 7398 Model FC251 UR O P R O X select m ONE 1 YEAR LIMITED WARRANTY EURO PRO Operating LLC warrants this product to be free from defects in material and workmanship for a period of one 1 year from the date of the original purchase when utilized for normal household use subject to the following conditions exclusions and exceptions If your appliance fails to operate properly while in use under normal household conditions within the warranty period return the complete appliance and accessories freight prepaid to EURO PRO Operating LLC 94 Main Mill Street Door 16 Plattsburgh NY 12901 If the appliance is found to be defective in material or workmanship EURO PRO Operating LLC will repair or replace it free of charge Proof of purchase date and 16 95 to cover the cost of return shipping and handling must be included Non durable parts including without limitation filters brushes and electrical parts which normally require replacement are specifically excluded from warranty The liability of EURO PRO Operating LLC is limited solely to the cost of the repair or replacement of the unit at our option This warranty does not cover normal wear of parts and d
4. TING INSTRUCTIONS Remove the filter from the filter grill The post motor filter is located on the left hand side of the vacuum Rinse the filter in lukewarm water and dry the filter completely Do not use a washing machine to rinse the filter Do not use a hair dryer to dry it Air dry only Never operate the vacuum without ALL the filters in place When the filter is dry replace into the filter grill and then into the unit A severely solid or clogged filter should be thoroughly washed in lukewarm water A mild detergent can be used if required Ensure that the filter is completely dry before re installing into the vacuum Please Note The HEPA Dust Cup Filter is washable It should however be replaced every six 6 months to ensure peak performance of your vacuum The Post Motor Filter is washable It should however be replaced every three 3 months to ensure peak performance of your vacuum Important Make sure that ALL filters are completely dry before re installing back in the hand vacuum Important All filters should be checked regularly for signs of damage preferably after each cleaning task The filters must be replaced immediately if they become damaged Always disconnect the vacuum from the electrical outlet when checking the filters OPERATING INSTRUCTIONS Removing amp Cleaning the HEPA Dust Cup Filter Warning Always unplug the unit from electrical outlet before opening the Dust Cup c
5. ard or sharp objects such openings away from your face and as glass nails screws coins etc body SAVE THESE INSTRUCTIONS For Household Use Only WARNING To reduce the risk of electric shock this appliance has a polarized plug one blade is wider than the other This plug will fit in a polarized outlet only one way If the plug does not fit fully in the outlet reverse the plug If it still does not fit contact a qualified electrician to install the proper outlet Do not modify the plug in any way Rev 12 02B GETTING TO KNOW YOUR BAGLESS CYCLONIC CANISTER 1 Power Nozzle On Off Button 12 Dust Cup Handle 2 Power Nozzle 13 Tool Tray 3 Telescopic Tube 14 Flexible Hose 4 Power Nozzle Power Cord 15 HEPA Filter 5 Manual Variable Suction Control 16 HEPA Filter Cleaning Brush 6 Receptacle for Power Nozzle Cord 17 Connecting Power Cord 7 Head Light 18 Connecting Power Cord Receptacle 8 Post Motor Filter Frame 19 Crevice Tool 9 Power On Off Button 20 Upholstery Brush 10 Vacuum Handle 21 Dusting Brush 11 Cord Rewind Button Snaps on to upholstery brush 22 Floor to Carpet Brush Technical Specifications Main Unit Voltage 120V 60HZz Power 10 5 Amps With Motorized Power Head Voltage 120V 60 Hz Power 12 Amps PLEASE NOTE The white pleated filter material in the HEPA Dust Cup Filter will discolor over time This is NORMAL and will NOT affect the performance of the filter If the HEPA
6. d Do not use hose Do not allow plug to whip when cord as a handle close a door on cord rewinding l or pull cord around sharp edges or 20 Use only on dry indoor surfaces corners Do not run appliance over cord 21 Do not use for any purpose other than Keep cord away from heated surfaces described in this user s guide 7 Do not unplug by pulling on cord To 22 Use only extension cords UL rated or unplug grasp the plug not the cord cUL at 15 amperes extension cords 8 Do not handle plug or vacuum cleaner rated for less amperage may overheat with wet hands Do not use outdoors or Care should be taken to arrange the on wet surfaces cord so that the cord cannot be pulled Do not put any objects into openings Do or tripped over not use with any opening blocked and 23 Do not put any objects into openings do not restrict airflow Keep all openings Do not use with any opening blocked free of dust lint hair and anything that Keep free of dust lint hair and may reduce airflow anything else that may reduce air flow 10 Keep hair loose clothing fingers and all 24 Store your appliance indoors in a cool 11 Do not pick up hot coals cigarette butts parts of body away from openings and dry area moving parts 25 Keep your work area well lit 26 Do not immerse the hand vacuum into matches or any hot smoking or burning water or other liquids objects 27 Keep end of hose wands and other 12 Do not pick up h
7. ing is not covered by your warranty Mark the outside of your package ATTENTION CUSTOMER SERVICE We are constantly striving to improve our products therefore the specifications contained herein are subject to change without notice OWNERSHIP REGISTRATION CARD Please fill out and mail the product registration card within ten 10 days of purchase The registration will enable us to contact you in the unlikely event of a product safety notification By returning this card you acknowledge to have read and understood the instructions for use and warnings set forth in the accompanying instructions RETURN TO EURO PRO Operating LLC 94 Main Mill Street Door 16 Plattsburgh NY 12901 Model FC251 Appliance model Date purchased Name of store Owner s name Address City State Prov Zip Postal Code Printed in China 9 FOR REPLACEMENT FILTER INFORMATION or for Technical Support for Model FC251 Call Customer Service 1 800 798 7398 Monday to Friday 8 30 A M 5 00 P M Eastern Standard Time Please Note The HEPA Dust Cup Filter is washable It should however be replaced every six 6 months to ensure peak performance of your vacuum The Post Motor Filter is washable It should however be replaced every three 3 months to ensure peak performance of your vacuum Important Make sure that ALL filters are completely dry before re installing back in the hand vacuum IMPORTANT SAFETY INSTRUCTIONS When using yo
8. ll as 0 3 microns many times smaller than a human hair Because of this incredible filtration performance the HEPA Dust Cup Filter will quickly accumulate inside the white filter folds many fine dust particles that are difficult to see but which will eventually block or reduce your suction power if not cleaned properly Clean the HEPA Filter as described in this section then reconnect unit and proceed with vacuuming 6 Vigorously TapClean the HEPA Dust Cup Filter on a hard surface until no more dust is observed falling out from between the pleats of the filter Please note that there is a filter Ta brush included in the tool tray that you can use to clean the pleats of the HEPA filter See illustrations at right PRECAUTIONARY MEASURES Important Ifthe suction opening of the unit the hose or the chrome telescopic tube are BLOCKED switch off the vacuum cleaner and remove the blocking substance before you start the unit again 1 Do not operate the vacuum cleaner too close to heaters or radiators 2 Before inserting the power plug into the wall outlet make sure that your hands are dry 3 Before you start vacuuming make sure to remove large or sharp objects that might damage the dust bag S 4 When pulling out the power plug from the wall outlet pull the plug not the power cord 5 Do not pick up anything that is burning or smoking such as cigarettes matches or hot ashes
9. oes not apply to any unit that has been tampered with or used for commercial purposes This limited warranty does not cover damage caused by misuse abuse negligent handling or damage due to faulty packaging or mishandling in transit This warranty does not cover damage or defects caused by or resulting from damages from shipping or repairs service or alterations to the product or any of its parts which have been performed by a repair person not authorized by EURO PRO Operating LLC This warranty is extended to the original purchaser of the unit and excludes all other legal and or conventional warranties The responsibility of EURO PRO Operating LLC if any is limited to the specific obligations expressly assumed by it under the terms of the limited warranty In no event is EURO PRO Operating LLC liable for incidental or consequential damages of any nature whatsoever Some states do not permit the exclusion or limitation of incidental or consequential damages so the above may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from state to state Important Carefully pack item to avoid damage in shipping Be sure to include proof of purchase date and to attach tag to item before packing with your name complete address and phone number with a note giving purchase information model number and what you believe is the problem with item We recommend you insure the package as damage in shipp
10. ontainer 1 Push the Power On Off button to Off and disconnect the power cord from the wall outlet 2 Remove the flexible hose 3 Push the dust cup lock button located just underneath the dust cup and remove the dust cup 4 Hold dust cup over a waste basket and depress the dust cup open button to open the dust cup Dispose of the dust inside Note If dust is tightly packed and difficult to remove tap the side of the dust cup lightly against the side of the garbage can 5 To remove the HEPA dust cup filter from the dust cup open the latch and lift the HEPA filter See illustration below Lift f ee i fe 7 r ri i f r vr a E i Y Fi fl es eas 3 P f Y J de i L a A E rd A os p i aes sd a oio ei Wine rT EAN py le D me ie i o pen p m Pi i a a Af _ Warning After each Use Always remove the HEPA Filter from the Dust Cup then vigorously TapClean HEPA Filter until no more dust can be removed Important When TapCleaning the HEPA filter hold the HEPA filter from the top rim and tap ONLY the bottom rim against the side of the waste container NEVER tap directly on the pleated folds of the HEPA filter ___ top Rim t Bottom Rim IMPORTANT Please Note The TapClean HEPA Dust Cup Filter will stop most of the tiniest dust particles from re entering the air you breathe In fact it stops 99 97 of all particles as sma
11. ube into the floor Jii brush as showin oe the illustration P LA at right E Using Power Nozzle 1 Connecting the power nozzle with the telescopic tube A Depress the button on the telescopic tube and insert it into the slot on the power nozzle elbow B Push the telescopic tube down until you hear a click see illustration below Telescopic Tube Power Nozzle 2 Insert the power nozzle cord plug into the power socket on the electric hose To start power nozzle press the On Off button that is located on the power nozzle Crevice Tool and Dusting Brush 1 Crevice Tool For radiators crevices corners baseboards and between cushions 2 Upholstery Brush The dusting brush is used for the furniture 3 Dusting Brush The dusting brush is used F for the furniture venetian blinds books lamp shades and shelves This is just snapped on to the upholstery brush Variable Suction Control Your vacuum cleaner includes a variable suction control valve on the hose extension The suction power can be adjusted by moving the slide to the desired position For example Less suction is required on upholstery and draperies compared to thick shag carpets which require maximum suction Using your Vacuum Note Once all attachments are in place unwind a sufficient length of cable and insert the plug into the wall outlet A yellow mark on the power cord shows the ideal cable length Don t pull the po
12. ur Bagless Cyclonic Canister vacuum basic safety precautions should always be observed including the following WARNING To reduce the risk of fire electrical shock or injury 13 Do not use without filters in place 1 Do not leave vacuum cleaner unattended 14 Turn off all controls before plugging or when it is plugged in Unplug from unplugging vacuum cleaner outlet when not in use and before filters 15 Use extra care when vacuuming on 2 To reduce the risk of electric shock do Stairs not use outdoors or on wet surfaces 16 Do not pick up flammable or 3 Do not allow children to use as a toy combustible materials lighter fluid Close attention is necessary when used gasoline kerosene etc or use in the by or near children presence of explosive liquids or vapor 4 Use only as described in this manual Use 17 Do not pick up toxic material chlorine only manufacturer s recommended bleach ammonia drain cleaner etc attachments 18 Do not use in an enclosed space filled 5 Do not use with damaged cord or plug Do with vapors given off by oil based not use vacuum cleaner if it has been paints paint thinner moth proofing dropped damaged left outdoors or substances flammable dust or other dropped into water Return appliance to explosive or toxic vapors EURO PRO Operating LLC for 19 Always unplug this appliance before examination repair or adjustment connecting or disconnecting vacuum 6 Do not pull or carry by cor
13. wer cord beyond the red mark 1 Insert the power plug into the wall outlet 2 Press the Power On Off button located on the unit to turn the vacuum cleaner On Power On Off Button 3 To rewind the power cord press the cord rewind button with one hand and guide the power cord with the other hand to ensure that it does not whip causing damage or injury Cord Rewind Button Yellow Symbol red Symbol 4 To adjust the suction slide the variable suction control button to control the suction power of the vacuum cleaner See illustration below Manual Variable Suction Control Curved Wand Hose Extension Motor Thermostat Important This motor is equipped with a motor protective thermostat If for some reason the vacuum cleaner should overheat the thermostat will automatically turn the unit off Should this occur unplug the vacuum cleaner from the wall outlet and turn off switch Remove dust cup and empty Clean dust cup filter Allow the unit to cool for approximately 1 hour To restart re plug into wall outlet and turn switch back on