Home

Eton FR405 User's Manual

image

Contents

1. CA 94303 USA LIMITED WARRANTY Retain the warranty information from your warranty card with your proof of purchase or the Limited Warranty information can also be viewed at www etoncorp com SERVICE FOR YOUR PRODUCT To obtain service for your product we recommend first contact ing an Et n service representative at 1 800 872 2228 US 1 800 637 1648 Canada 650 903 3866 or customersvc etoncorp com for problem determination and trouble shooting If further service is required the technical staff will instruct how to proceed based on whether the radio is still under warranty or needs non warranty service WARRANTY If your product is still in warranty and the Et n service representative determines that warranty service is needed a return authorization will be issued and instructions for shipment to an authorized warranty repair facility Do not ship your radio back without obtaining the return authorization number 11 American Red Cross FR405 OWNER S MANUAL SERVICE FOR YOUR PRODUCT NON WARRANTY If your product is no longer under warranty and requires service our technical staff will refer you to the nearest repair facility that will be able to best handle the repair For service outside North America please refer to the distributor information included at time of purchase receipt 12 American Red Cross FR405 OWNER S MANUAL 13 14 GU A DE OPERACI N DE American Red Cross FR405 Ameri
2. DE OPERACI N DE American Red Cross FR405 DIAGRAMAS SPEER uchr CONTROLS an SELECTOR TUNING CONTRO LU J J ae Aer Radio 0202020 AM 530 600 700 908 1100 1400 171p kHz 9 99 owen 0 0 0 0 0 0 0 0 GENTERATOR 0 0 0 0 0 0 0 0 0 RANK 90900090000090000 TM o2 96 100 9 9 ROG NK XX MMM 0 095949 T 0 O 0 0 I 0002000009000020 me bis K mmes or 9 CERO D hea FR 405 L POWER w SIENOFFALERT BATTERY CHANNEL DYNAMOADAPTOR SELECTOR 1 Power Battery Dynamo Adaptor OFF 2 WX Channel Selector 3 Siren ON OFF 4 Volume Control 5 Tuning Control 6 Band Selector 7 Light Controls 8 Speaker 9 Power Generator Crank 16 GU A DE OPERACI N DE American Red Cross FR405 DIAGRAMAS continuado PUSH HERE qd BATTERY COMPARTMENT COVER 1 Battery Compartment Cover 2 Earphone Jack 3 AC Adapter Jack 4 Cell Phone Charger Jack 17 GU A DE OPERACI N DE American Red Cross FR405 AJUSTE INICIAL T 2 Abra el compartimento de la bater a cuya tapa se desliza hacia abajo tras una pulsaci n firme en el centro de la bisagra Conecte el paquete de bater as FUENTES DE ALIMENTACI N DUN gt Paquete de bater a recargable incluido 3 bater
3. SPECIFICATIONS Ni MH 3 6 volt DC 450 mAh American Red Cross FR405 OWNER S MANUAL AC ADAPTER SPECIFICATIONS Output 4 5 volt DC negative polarity 100 milliampere plug tip outer diameter 3 4mm inner diameter 1 3mm AC adapter use automatically charges the rechargeable battery pack Only charge the battery pack with a 100 milliampere AC adapter If an AC adapter rated greater than 100 milliampere is used disconnect the rechargeable battery pack IMPORTANT BATTERY INFORMATION To minimize the possibility of battery acid leakage only use high quality alkaline lithium or rechargeable nickel metal hydride bat teries Never intermix old with new or different brands or types of batteries Damage caused by battery acid leakage is not covered by this product s warranty WARRANTY REGISTRATION To ensure full warranty coverage or product updates registration of your product should be completed as soon as possible after purchase or receipt You may use one of the following options to register your product 1 By visiting our website at http www etoncorp com 2 Mail in enclosed warranty card 3 Mail your registration card or information to following ad dress include your name full mailing address phone number email address model purchased date purchased retail vendor name 10 American Red Cross FR405 OWNER S MANUAL WARRANTY REGISTRATION continued Et n Corporation 1015 Corporation Way Palo Alto
4. American Red Cross FR405 by Et n AM FM Water Resistant Radio with NOAA Flashlight Siren and Cell Phone Charger Owner s Manual American Red Cross Radio Line By American ETO N Red Cross re inventing radio www etoncorp com American Red Cross FR405 OWNER S MANUAL American Red Cross Radio Line By American Red Cross eTOf inventing radio www etoncorp com DO YOU NEED HELP Contact Us Et n Corporation 1015 Corporation Way Palo Alto CA 94303 USA 1 800 872 2228 U S 1 800 637 1648 Canada 650 903 3866 worldwide M F 8 30 4 00 Pacific Standard Time www etoncorp com WARNING Do not expose this appliance to rain or moisture Do not submerge or expose for extended period to water Protect from high humidity and rain Only operate within specified temperature range 0 C to 40 C Unplug immediately if liquid has been spilled or any object has fallen into the apparatus Clean only with a dry cloth Do not use detergents or chemical solvents as this might damage the finish Unplug and disconnect external antennas during lightning storms Do not remove cover or back Refer servicing to qualified service personnel ENVIRONMENT Disposal According to the European Directive 2002 96 EC all electrical and electronic products must be collected mmm separately by a local collection system Please act according to your local rules and do not dispose of
5. EE UU GARANT A LIMITADA Conserve la informaci n de garant a de su tarjeta de garant a con su comprobante de compra La informaci n de Garant a Limitada puede ser tambi n le da en www etoncorp com 23 GU A DE OPERACI N DE American Red Cross FR405 SERVICIO PARA SU PRODUCTO Para solicitar alg n servicio para su producto le recomendamos contactar primero al representante de servicio de Et n llamando al n mero de tel fono 800 872 2228 para los EE UU o al n mero de tel fono 800 637 1648 para Canad o bien al 650 903 3866 6 mande un mail a customersvc etoncorp com para la localizaci n y resoluci n del problema Si requiere un servicio adi cional el equipo t cnico lo instruir de como proceder conside rando si la radio a n posee garant a o si necesita servicio t cnico para un producto que ya no posee garant a GARANT A Si su producto a n posee garant a y el represent ante de servicio de Et n determina que el servicio de garant a sea necesario se le enviar una autorizaci n de retorno e instruc ciones de env o a una unidad de servicio de reparaci n autorizada de la garant a NO ENV E su radio de regreso sin haber recibido el n mero de autorizaci n de retorno SIN GARANT A Si su producto ya no posee garant a y requiere servicio de nuestro equipo t cnico el representante de servicio de Et n le indicar la unidad de reparaci n m s cercana de su localidad que pueda ofrecer el m
6. as del tipo AA no incluidas Adaptador cargador AC incluido Giro continuo de la manivela incluso sin bater as insertadas CARGA DEL PAQUETE DE BATER A 1 2 Coloque el conmutador BATTERY DYNAMO ADAPTER OFF en la posici n OFF Gire la manivela del din mo en sentido de las agujas de reloj o contra el sentido de las agujas del reloj dando aprox 2 giros por segundo durante 90 segundos Despu s de la carga coloque el conmutador en la posici n DYNAMO ADAPTOR Durante la carga brilla el LED rojo de carga OPERACI N CON BATER A DEL TIPO AA 1 Abra el compartimento de bater a 18 GU A DE OPERACI N DE American Red Cross FR405 OPERACI N CON BATER A DEL TIPO AA 2 Coloque 3 bater as del tipo AA poniendo atenci n en el diagrama de polaridad 3 Para la alimentaci n de corriente coloque el conmutador POWER en la posici n BATTERY UTILIZACI N DE UN ADAPTADOR AC Despu s de su enchufe el adaptador AC trabaja como cargador y carga el paquete de bater a Ni MH interna La carga demora aprox 8 horas hasta alcanzar su nivel de carga completa 1 Inserte eladaptador en el enchufe DC 4 5 V 2 Para la alimentaci n de corriente coloque el conmutador BATTERY DYNAMO ADAPTER OFF en la posici n DYNAMO ADAPTER Utilice s lo un adaptador AC con 4 5 VDC polaridad negativa y capacidad de corriente de 100 mA Para pedir un adaptador AC correcto llame al n mero gratuito que se indiq
7. can Red Cross Radio Line By American E Red Cross ETON reinventing radio www etoncorp com NECESITA AYUDA CONT CTENOS Eton Corporation 1015 Corporation Way Palo Alto CA 94303 EE UU 1 800 872 2228 EE UU 1 800 637 1648 Canad 650 903 3866 todo el mundo Lunes a viernes 8 30 16 00 hrs Hora Est ndar del Pac fico www etoncorp com ADVERTENCIA No exponga este dispositivo a lluvia o humedad No exponga o sumerja este aparato al agua durante un per odo largo Proteja el aparato de gran humedad y lluvia Utilice la unidad solamente dentro de un rango de temperatura especificado 0 C a 40 C Desenchufe la unidad inmediatamente si ha ca do l quido sobre alg n objeto dentro de la radio Limpie la unidad solamente con un pa o seco No utilice detergentes o disolventes que puedan da ar la cubierta del dispositivo Desenchufe y desconecte las antenas externas durante tormentas con rel mpagos No quite la cubierta o la parte posterior Si este producto muestra alg n problema p ngase en contacto con personal cualificado de servicio MEDIO AMBIENTE ELIMINACI N AK De acuerdo a la Directiva Europea 2002 96 EC todos los aparatos el ctricos y electr nicos deben ser recolectados en forma separada por un sistema local de recolecci n Por favor act e seg n las normas de su localidad y no elimine los aparatos antiguos en su basura del hogar usual 15 GU A
8. ejor servicio de reparaci n Para servicio fuera de Am rica del Norte por favor consulte la informaci n del distribuidor incluido en la fecha de la compra o del recibo 24 GU A DE OPERACI N DE American Red Cross FR405 25 American Red Cross Radio Line By er n re inventing radio www etoncorp com Et n Corporation Corporate Headquarters 1015 Corporation Way Palo Alto California 94303 USA tel 1 650 903 3866 tel 1 800 872 2228 fax 1 650 903 3867 Et n Europe Lextronix Germany Rosenstrasse 2 D 10178 Berlin Germany tel 49 0 30 243102142 Et n Canada 1 Yonge Street Suite 1801 Toronto Ontario M5E 1W7 Canada tel 1 416 214 6885 Designed by Et n Corporation and assembled in China Copyright 2007 Et n Corporation Al rights reserved v 07 31 07
9. ete de bater a recargable El paquete de bater a se debe cargar s lo con un adaptador AC de 100 miliamperios En caso que usar un adaptador AC con m s de 100 miliamperios debe desconectarse el paquete de bater a recargable INFORMACI N IMPORTANTE PARA LA BATER A Para minimizar la posibilidad de una fuga de cido de la bater a deben usarse exclusivamente bater as alcalinas de alta calidad de litio o bater as recargables de n quel metal hidruro Nunca se deben mezclar bater as viejas con nuevas o bien diferentes marcas o tipos de bater as Un eventual da o causado por una fuga de cido de bater a no est cubierto por la garant a del producto 22 GU A DE OPERACI N DE American Red Cross FR405 REGISTRO DE GARANT A Para asegurar la cobertura completa de la garant a o adquirir actualizaciones del producto debe registrar su producto tan pronto posible despu s de la compra o recibo del producto Usted puede utilizar una de las siguientes opciones para registrar su producto 1 Ya sea visitando nuestro sitio Web en http www etoncorp com 2 Enviando por correo la tarjeta de garant a suministrada 3 Env e por correo su tarjeta de registro o informaci n a la direc ci n siguiente escriba su nombre direcci n postal completa n mero de tel fono modelo comprado fecha de compra distribuidor del producto donde ha adquirido el producto Et n Corporation 1015 Corporation Way Palo Alto CA 94303
10. ge socket American Red Cross FR405 OWNER S MANUAL CELL PHONE CRANK CHARGING continued Select the correct charging tip for your phone Plug charging tip into the charging cord and into the phone s charging socket Rotate the dynamo crank about 2 turns per second TURNING THE RADIO ON AND OFF Turn it on with the POWER switch 1 2 3 Select the BATTERY position when using AA batteries Select the DYNAMO ADAPTER position when powering via the AC adapter or internal rechargeable Ni MH battery pack To turn off set POWER switch to OFF ADJUSTING THE VOLUME Set VOLUME knob to desired level TUNING IN STATIONS 1 Select AM FM or WEATHER WX with the band selector switch For FM and WEATHER WX fully extend the telescopic antenna Adjust the volume with the VOLUME knob Tune stations with the TUNING knob or tune in WEATHER WX with the 7 position switch American Red Cross FR405 OWNER S MANUAL TO RECEIVE WEATHER ALERTS Tune into your strongest weather station Select a comfortable volume level Leave the radio on and select the ALERT position with the SIREN OFF ALERT switch When there are weather alerts the radio will come on at the volume that you have set LIGHTS Set the LIGHT OFF FLASH switch to the FLASH or LIGHT position SIREN Set the SIREN OFF ALERT switch to the SIREN position EARPHONE JACK Plug in earphones not included BATTERY PACK
11. ue el conmutador POWER en OFF AJUSTE DEL VOLUMEN Coloque la perilla VOLUME en el nivel deseado 20 GU A DE OPERACI N DE American Red Cross FR405 SINTONIZACI N DE ESTACIONES 1 Seleccione AM FM o WEATHER WX con el conmutador selector de banda Para la sintonizaci n de FM y WEATHER WX se recomienda extender completamente la antena telesc pica 2 Ajuste el volumen con la perilla VOLUME 3 Las estaciones se pueden sintonizar con la perilla TUNING o bien sintonizando WEATHER WX con el conmutador de 7 posiciones PARA RECIBIR ALERTAS DE CLIMA Sintonice la estaci n meteorol gica con la se al m s fuerte Se leccione un nivel de volumen confortable Deje la radio activada y seleccione la posici n ALERT con el conmutador SIREN OFF ALERT En caso de emisi n de alertas meteorol gicas la radio se activa con el volumen ajustado previamente LUZ Coloque el conmutador LIGHT OFF FLASH en la posici n FLASH o LIGHT SIRENA Coloque el conmutador SIREN OFF ALERT en la posici n SIREN 21 GU A DE OPERACI N DE American Red Cross FR405 ENTRADA DE AURICULARES Enchufe los auriculares no incluidos ESPECIFICACIONES DEL PAQUETE DE BATER A Ni MH 3 6 V DC 450 mAh ESPECIFICACIONES DEL ADAPTADOR AC Salida 4 5 V DC polaridad negativa 100 miliamperios di metro exterior de la punta de enchufe 3 4mm di metro interior 1 3 mm El adaptador AC realiza una carga autom tica del paqu
12. ue enel inicio de este manual y pregunte por el Dpto de Piezas para pedir el N de pieza GPU3504 OPERACI N DE EMERGENCIA SIN FUENTE DE ALIMENTACI N 1 Coloque el conmutador POWER en la posici n DYNAMO ADAPATOR 2 Mientras siga girando continuamente la manivela del din mo se pueden sintonizar las estaciones de radio y usar la luz y la sirena 19 GU A DE OPERACI N DE American Red Cross FR405 CARGA DE MANIVELA PARA TEL FONO CELULAR Ya que las bater as de los tel fonos celulares var an en sus rangos de corriente no podemos especificar los niveles de carga o tiempo de uso 10 a 15 minutos de giro de manivela podr an permitir 1 minuto o m s de conversaci n por tel fono 1 Zi UJ Coloque el conmutador POWER en la posici n OFF Inserte el cable de carga de tel fono celular en el enchufe de carga de tel fono Seleccione la punta de carga correcta para su tel fono celular Inserte la punta de carga en el cable de carga y en el enchufe de carga de tel fono Gire la manivela de din mo con una velocidad de aprox 2 giros por segundo ACTIVACI N Y DESACTIVACI N DE LA RADIO La radio se activa con el conmutador POWER Seleccione la posici n BATTERY cuando usa bater as del tipo AA Seleccione la posici n DYNAMO ADAPTER en caso de una alimentaci n de corriente mediante el adaptador AC o el paquete interno de bater a Ni MH recargable Para desactivar la radio coloq
13. wise or counter clockwise about 2 turns per second for 90 seconds After charging select the DYNAMO ADAPTOR position for power While charging the red LED charging light illuminates AA BATTERY OPERATION 1 2 3 Open the battery compartment Install 3 AA batteries observing polarity diagram For power set the power selector switch to the BATTERY position American Red Cross FR405 OWNER S MANUAL USING AN AC ADAPTER Once plugged in the AC adapter acts as a charger charging the internal Ni MH battery pack Charge it for 8 hours to achieve a full charge 1 Plug the adapter into the DC 4 5 V socket 2 For power set the BATTERY DYNAMO ADAPTER OFF switch to the DYNAMO ADAPTER position Only use an AC adapter of 4 5 VDC negative polarity and 100mA current capability To order the correct AC adapter call the toll free number shown at the beginning of this manual ask for the parts department and order part GPU3504 EMERGENCY OPERATIONS WITH NO POWER SOURCE 1 Set power selector switch to DYNAMO ADAPTOR 2 While continually turning the dynamo crank the radio lights and siren functions will work CELL PHONE CRANK CHARGING Because cell phone batteries vary in their current ratings we cannot specify charging rates or usage time 10 to 15 minutes of cranking may result in 1 or more minutes of talk time 1 Set POWER switch to OFF position 2 Plug the cell phone charging cord into the Phone Char
14. your old products with your normal household waste American Red Cross FR405 OWNER S MANUAL SPEAKER uerrconmois wo stcion Tun contr LEJ 0 530 600 700 sod 1100 100 vos MS ORAT pon 0 00 0 0 0 00 conflit SOLO POP OLD ed 2020202020202020 mas o2 96 100 hios 105 sore x oo j zi voume SIRENOFFALERT R yx n CHANNEL ATER DINAMOADAFTOR SELECTOR Power Battery Dynamo Adaptor OFF Weather Channel Selector Siren ON OFF Volume Control Tuning Control Band Selector Light Controls Speaker Power Generator Crank O ONOUAWN American Red Cross FR405 OWNER S MANUAL DIAGRAMS continued PUSH HERE G BATTERY COMPARTMENT COVER 1 Battery Compartment Cover 2 Earphone Jack 3 AC Adapter Jack 4 Cell Phone Charger Jack American Red Cross FR405 OWNER S MANUAL INITIAL SETUP i 2 Open the compartment it slides downward with firm pressure at center of hinge Connect the battery pack POWER SOURCES DUN gt Rechargeable battery pack included 3 AA batteries not included AC adapter charger included Continually turning the crank even with no batteries installed CHARGING THE BATTERY PACK 1 2 3 Switch the BATTERY DYNAMO ADAPTER OFF switch to the OFF position Turn the dynamo crank clock