1. Specifications are subject to change without notice ETA ETA S20RT SYSTEMS AC Distribution amp Suppressor Unit Leading by Design FN WARNING WHEN THE DEVICE IS IN USE e To prevent electric shock do not remove the product cover as there are high voltage components inside Refer all servicing to ETA Systems e Should any of the following irregularities occur during use immediately switch off the power disconnect the power cord from the AC outlet and contact ETA Systems Do not to attempt to continue operation with the product as this may cause fire or electric shock e Smoke or strange smell coming from the unit e If the product falls or the case is damaged e f water or any metallic objects falls into the product e f the power supply cord is damaged in any way e Ifthe unit is malfunctioning e Do not insert or drop metallic objects or flammable materials into the ventilation holes of the product s cover as this may result in electric shock or fire e Do not place any containers with liquid or metallic objects on the top of the product If any liquid spills into the unit fire or electric shock may result e ever operate this product or touch the power supply cord during an electrical storm electric shock may result e ever exceed the power rating on the product when connecting equipment Fire and or property damage may result e Operate the product only with the voltage specified on the unit Fire
2. ETA S20RT ETA AC Distribution amp Suppressor Unit N SYSTEMS Leading by Design ETA S20RT SYSTEMS Leading by Design AC Power Distribution amp AC Suppressor Unit with Remote Activation ETA ETA S20RT amp Surge Suppressor 1601 Jack McKay Blvd Ennis Texas 75119 U S A Telephone 800 321 6699 Fax 800 996 3821 ae ETAsys com Specifications are subject to change without notice ETA ETA S20RT SYSTEMS AC Distribution amp Suppressor Unit Leading by Design TABLE OF CONTENTS mportant Safety INStrUCtiOnS cccccccccccesceeeeseseeeceeeeseeeeseeesaeceseecceeeeseescseeceeecsesecseeseeeceesseeeesseeenseessees 3 troduction A E ER E a A 5 Key Features and Applications cccccccceeeececeeeeeeeeeeeeeeeceeeeseeeeecaeeescaeeesceeeessceseeecneeeesseresenseeennteees 6 FROME Panel PG AtUiOSs an e Stet ainias ltd eaidis ac eee tae ee a E rE A 7 Rear Panel FC atures iscycce a he secrasdevatnaidanessaungenewtarpese Nanestdiuinsstugniaciystacaetssgatsheapescdiuiuneigietbendyadeamaphiesteats 8 MS TAA O aa SEEE E E E E EE E T E T 9 Specifications sneen aana e E O A A Ea 10 Waranty erona ain a a E a a A E a e E E E S 12 1601 Jack McKay Blvd Ennis Texas 75119 U S A Telephone 800 321 6699 Fax 800 996 3821 a ETAsys com Specifications are subject to change without notice ETA S20RT ETA AC Distribution amp Suppressor Unit SYSTEMS N i Leading by
3. a short period of time If the breaker is tripped you must first remove the load from the ETA S20RT and then push to reset 3 Power Switch To turn the ETA S20RT On or Off press the switch to the ON or OFF position See rear panel Remote Bypass Switch 4 USB Port 5VDC 1A Convenient USB port for connecting USB rack lighting or for charging external device batteries Note Will not charge all products Some devices require licensed charging circuitry 5 Power ON Indicator Will illuminate Blue when the AC Mains Power Switch is in the ON Position 6 AC Fault Indicator Although the Clamping Suppression circuit virtually assures protection from most transient voltage spikes and surges Nature has a way of occasionally creating electrical forces that are beyond the capabilities of any device to absorb without some degree of damage In the rare instance that this occurs and the circuit has been damaged the Red AC Fault LED indicator will illuminate and an internal buzzer will sound The ETA S20RT will shut Off permanently until the unit is repaired Be advised that activation of this fault condition and the associated repair is not covered under warranty Note If the AC Fault LED is illuminated it is important to have all equipment that was connected to that AC Mains Line be inspected for proper operation 7 EVS Protect Indicator This LED will illuminate when an extreme over or under voltage condition has occurred A power line voltage
4. and or electric shock may result if a higher voltage is used e Do not modify kink or cut the power cord Do not place the power cord in close proximity to heaters and do not place heavy objects on the power cord including the product itself doing so may result in fire or electrical shock e Ensure that the safety ground terminal is connected to a proper ground Never connect the ground to a gas pipe as a catastrophic disaster may result e Be sure the installation of the product is stable avoid slanted surfaces as the product may fall and cause injury or property damage CAUTION WHEN INSTALLING THE PRODUCT e Plugging in or unplugging the power cord with wet hands may result in electric shock e Never move the unit with the power cord plugged into the wall as damage to the power cord may result e When unplugging the cord from the wall grasp the plug NOT the cord e Never install this product in humid or dusty locations nor in direct sunlight near sources of heat or in areas where sooty smoke or steam are present Fire and electric shock may result e Keep all sides of the unit at least 31 2 away from objects that may obstruct air flow to prevent the unit s internal temperature rise CAUTION WHEN THE DEVICE IS IN USE e Never place heavy objects on the product causing it to fall and or break resulting in personal injury and property damage In addition the product itself may fall and cause injury and property damage e
5. ohm W Resistor In Series with 12VDC and LED Remote Voltage Activation REMOTE ACTIVATION DC OUTPUT 100mA EXTSW REMOTE BYPASS 12 GND REMOTE ACTIVE Apply 5V 24VDC and Connect a Ground to the GND Terminal to Activate the Unit Note It is OK to Have Two Wires In the Same Terminal To Remote Panel LED Use the 12 and GND Terminals Note Use a 2K ohm W Resistor In Series with 12VDC and LED 1601 Jack McKay Blvd Ennis Texas 75119 U S A Telephone 800 321 6699 Fax 800 996 3821 E19 ETAsys com Specifications are subject to change without notice ETA SYSTEMS Leading by Design SPECIFICATIONS Type Load Rating Safety Listings Front Panel Outlets USB Port Activation Switch Circuit Breaker Indicators Rear Panel AC Outlets LED Light Socket LED Light Switch Remote Activation Remote Activation Connector AC Mains Power Cord Technical Data Current Rating Operating Voltage Power Consumption Min Spike Clamping Voltage Max Spike Clamping Voltage Max Spike Clamping Resp Time Spike Clamping Voltage 100A Maximum Surge Current Energy Rating 2ms Noise Attenuation RFI EVS Limits Temperature Range Humidity Range Mechanical Chassis Finish Mounting Height Width Depth Weight ETA S20RT AC Distribution amp Suppressor Unit Power Conditioner amp Suppressor 20A ETL UL 60065 Standard 1 Unswitched 1 USB Charge Light Port 5V
6. Contact ETA Systems for instructions on cleaning the inside of the unit Large accumulations of dust inside the unit may result in heat buildup and fire e Ensure that the power supply plug is securely plugged into the wall outlet Never allow dust to accumulate on the power plug or inside the wall outlet e When cleaning the unit or the unit is not to be operated for an extended period unplug the power cord from the wall 1601 Jack McKay Blvd Ennis Texas 75119 U S A Telephone 800 321 6699 Fax 800 996 3821 aye ETAsys com Specifications are subject to change without notice ETA S20RT ETA AC Distribution amp Suppressor Unit N SYSTEMS Leading by Design INTRODUCTION Thank you for purchasing the ETA Systems ETA S20RT AC Distribution and Suppressor Unit The ETA S20RT has been designed to meet most installation requirements for AC power distribution and equipment power protection To light your rack the ETA S20RT incorporates a front panel USB port for lighting and equipment charging The rear of the rack can be illuminated by the optional AP GNL18 gooseneck LED lamp connected via an XLR style socket LED lamps are far superior in longevity along with heat reduction when compared to traditional incandescent lamps and the XLR input offers a better connection point over commonly used BNC type bases By utilizing the Remote Activation feature up to 20A of clean electrical power can be switched On or Off wit
7. DC 1A Rocker 20A Resettable AC Power On AC Fault EVS Protect 8 Outlets Total XLR Socket to Provide 12VDC for Optional AP GNL18 Gooseneck Lamp Two position On Off Latching Type Dry Contact Closure or 5V 24VDC 4 Position 3 5mm Phoenix Type Connection 9 2 74m 12 Gauge 20A Male AC Plug 20 Amps 102VAC 132VAC 8 Watts A460VRMS 3 000A 6000V 1 Nanosecond 1250Vp for 20us 6 500A 600 Joules 10dB 10kHz 40dB 100kHz 100dB 10MHz 95VAC Low 140VAC High Auto Reset 5 35 C 5 to 95 Relative Humidity Black Rack Mount 1 RU 1 75 1RU 44 5mm 19 482 6mm 8 203mm 5 5 Ibs 2 49kg 1601 Jack McKay Blvd Ennis Texas 75119 U S A Telephone 800 321 6699 Fax 800 996 3821 10 Specifications are subject to change without notice ETAsys com ETA S20RT ETA AC Distribution amp Suppressor Unit N SYSTEMS Leading by Design NOTES 1601 Jack McKay Blvd Ennis Texas 75119 U S A Telephone 800 321 6699 Fax 800 996 3821 11 ETAsys com Specifications are subject to change without notice ETA ETA S20RT SYSTEMS AC Distribution amp Suppressor Unit Leading by Design N LIMITED WARRANTY All products manufactured by ETA Systems are warranted to the original dealer installer industrial or commercial purchaser to be free from defects in material and workmanship and to be in compliance with our published specifications if a
8. Design IMPORTANT SAFETY INSTRUCTIONS The lightning flash with arrowhead symbol within an CAUTION equilateral triangle is intended to alert the user to the presence of uninsulated dangerous voltage within the RISK OF ELECTRIC SHOCK product s enclosure that may be of sufficient magnitude DO NOT OPEN 2 A 2 to constitute a risk of electric shock to persons RISQUE DE CHOC ELECTRIQUE ATTENTION F DE oe rl CAUTION The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance servicing instructions in the literature accompanying the product WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK DO NOT EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE 1 Read these instructions Keep these instructions Heed all warnings Follow all instructions 2 3 4 5 Do not use this device near water 6 Clean only with dry cloth 7 Do not block any ventilation openings Install in accordance with the manufacturer s instructions 8 Do not install near any heat sources such as radiators heat registers stoves or other device including amplifiers hat produce heat 9 Do not defeat the safety purpose of the polarized or grounding type plug A polarized plug has two blades with one wider than the other A grounding type plug has two blades and a third grounding prong The wide blade or the third prong are provided for your safety If the provided plug doe
9. L NOT BE LIABLE IN TORT OR CONTRACT FOR ANY DIRECT CONSEQUENTIAL OR INCIDENTAL LOSS OR DAMAGE ARISING OUT OF THE INSTALLATION USE OR INABILITY TO USE THE PRODUCTS THE ABOVE WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES INCLUDING BUT NOT LIMITED TO WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ETA Systems does not assume nor does it authorize any other person to assume or extend on its behalf any other warranty obligation or liability This warranty gives you specific legal rights and you may have other rights which vary from state to state SERVICE Should your ETA S20RT require service please contact the ETA Systems warranty department at 1 877 689 8055 ext 277 to obtain an RA number ETA Systems Tech Support can be reached at 1 800 321 6699 Visit our web site at www ETAsys com to see other ETA Systems products ETA SYSTEMS Leading by Design 2011 ETA Systems All rights reserved All other trademarks are the property of their respective owners ETA004090 RevA 7 11 1601 Jack McKay Blvd Ennis Texas 75119 U S A Telephone 800 321 6699 Fax 800 996 3821 12 ETAsys com Specifications are subject to change without notice
10. als the unit will activate See Remote Activation Drawings for details The terminals marked 12V and GND can be connected to a remote panel LED not included to indicate function when remotely activated 1601 Jack McKay Blvd Ennis Texas 75119 U S A Telephone 800 321 6699 Fax 800 996 3821 agi ETAsys com Specifications are subject to change without notice ETA S20RT ETA AC Distribution amp Suppressor Unit N SYSTEMS Leading by Design INSTALLATION Before installing it is recommended to read the entire manual to ensure proper operation and that all features are being utilized The ETA S20RT can be placed on a shelf or rack mounted in a standard 19 width rack When rack mounted placement within the rack is flexible however the ETA S20RT should be within 6 of a dedicated 20A AC outlet When rack mounting use Rack Rail type screws of 1 x 1 Always make sure the 20A outlet is properly inspected by a certified electrician prior to connecting the ETA S20RT Make sure to inspect the equipment that will be connected to the ETA S20RT to ensure it does not exceed 20A total amperage draw Remote Activation Connections Diagram Remote Activation via Hard Contact Switch REMOTE ACTIVATION DC OUTPUT 100mA EXTSW REMOTE BYPASS 12 GND Q REMOTE ACTIVE Use External Key or Panel Switch Hard Contact To Remote Panel LED Use the 12 and GND Terminals Note Use a 2K
11. below 95VAC or above 140VAC will trigger the EVS circuitry removing power from the switched outlets This abnormal voltage condition must be corrected before the ETA S20RT can be reset 1601 Jack McKay Blvd Ennis Texas 75119 U S A Telephone 800 321 6699 Fax 800 996 3821 27e ETAsys com Specifications are subject to change without notice ETA ETA S20RT SYSTEMS AC Distribution amp Suppressor Unit Leading by Design REAR PANEL FEATURES 00O 1 AC Mains Input Connect the 14 Gauge 9 3m power cord to a 20A 120VAC outlet to provide power to the ETA S20RT 2 AC Power Outlets These six outlets are Live when the front panel power switch is activated The two Unswitched Outlets are always live if the power cord is connected to 120VAC 3 XLR Light Socket A 12VDC XLR light socket provides power for the optional AP GNL18 light 4 Light Socket Power Switch Two position switch to power On Off the XLR light socket 5 Remote Activation There are two methods to remotely activate the ETA S20RT A External Switch The Ext SW terminals are connected to a latching type dry contact closure to activate the ETA S20RT Note The Remote Bypass switch must be shorted for Remote Activation This feature can be used for Emergency Power Down EPD when tied into a normally closed latching contact closure e g Fire Panel B DC Voltage When you apply 5V 24VDC to the Ext SW termin
12. h a simple latched dry contact closure With the closure of the remote activation switch 12VDC at 100mA is available to power a remote status LED An Emergency Power Down function or EPD can also be created by using the Remote Activation feature by simply keeping the Remote Activation contact closed until a condition occurs that requires a system shut down When the contacts are opened it will remove power from the switched outlets to protect equipment A rear mounted bypass switch disables the Remote Activation should the need arise The ETA S20RT features noise filtering for unwanted Radio Frequency Interference RFI that is commonly introduced into AC lines by nearby radio transmitters or wireless products EMI filters are incorporated to reduce noise and Electromagnetic Interference EMI from such items as electric motors and external switching power supplies The benefit of these filters can be seen on video products or audibly by reducing static pops and external signal interference Unstable AC Mains voltage is one of the main reasons for equipment failure The amount of energy that can be injected into the power system can be immense with voltages reaching 6kV or amperage peaks of 3000A These spikes are very fast and usually only last for a very short period of time The ETA S20RT s circuitry is very fast and can suppress unwanted energy within a nanosecond response and sustain the suppression up to 2 milliseconds thus ensuring virtually tro
13. ny This warranty shall extend from the date of purchase for a period of one year Additionally fuses and lamps carry no warranty ETA Systems will solely at its discretion replace at no charge or repair free of charge defective parts or products when the product has been applied and used in accordance with our published operation and installation instructions We will not be responsible for defects caused by improper storage misuse including failure to provide reasonable and necessary maintenance accident abnormal atmospheres water immersion lightning discharge or malfunctions when products have been modified or operated in excess of rated power altered serviced or installed in other than a workmanlike manner The original sales invoice should be retained as evidence of purchase under the terms of this warranty All warranty returns must comply with our returns policy set forth below When products returned to ETA Systems do not qualify for repair or replacement under our warranty repairs may be performed at prevailing costs for material and labor unless there is included with the returned product s a written request for an estimate of repair costs before any non warranty work is performed In the event of replacement or upon completion of repairs return shipment will be made with the transportation charges collect EXCEPT TO THE EXTENT THAT APPLICABLE LAW PREVENTS THE LIMITATION OF CONSEQUENTIAL DAMAGES FOR PERSONAL INJURY ETA SYSTEMS SHAL
14. r Mounted XLR Connector For 12VDC LED Lamp AP GNL18 Lamp Sold Separately Spike Suppression Up To 6000V AC Fault Indicator APPLICATIONS The flexible ETA S20RT was designed with features to be used in a variety of applications The ETA S20RT can be used solely for protection against voltage surges or for AC distribution The ETA S20RT can also be used for power conditioning to eliminate or reduce fuzzy video or frequency audio static pops The following are just a few examples of applications where the ETA S20RT can be used Restaurants Houses of Worship Schools Home Theaters Office Buildings Sports Bars 1601 Jack McKay Blvd Ennis Texas 75119 U S A Telephone 800 321 6699 Fax 800 996 3821 e Specifications are subject to change without notice ETAsys com ETA S20RT ETA AC Distribution amp Suppressor Unit N SYSTEMS Leading by Design FRONT PANEL FEATURES ETA ETA S20RT 20A AC Power Distributor amp Surge Suppressor 0 O00 1 Unswitched AC Outlet The 120VAC outlet is always live when the ETA S20RT power cord is plugged into an AC mains power source and voltage is present Note The AC mains power switch does not affect the Unswitched AC Outlet but it is protected with surge protection circuitry 2 AC Mains Breaker The 20A rated breaker will open if the combined draw of all AC outlets exceeds 20A Note The breaker is designed to exceed its rating for
15. s not fit into your outlet consult an electrician for replacement of the obsolete outlet 10 Protect the power cord from being walked on or pinched particularly at plugs convenience receptacles and the point where they exit from the device 11 Only use attachments accessories specified by the manufacturer 12 Use only with the cart stand tripod bracket or table specified by the manufacturer or sold with the device When a cart is used use caution when moving the cart device combination to avoid injury from tip over 13 Unplug this device during lightning storms or when unused for long periods of time 14 Refer all servicing to qualified service personnel Servicing is required when the device has been damaged in any way such as power supply cord or plug is damaged liquid has been spilled or objects have fallen into the device the device has been exposed o rain or moisture does not operate normally or has been dropped 15 WARNING To reduce the risk of fire or electric shock this device should not be exposed to rain or moisture and objects filled with iquids such as a vase should not be placed on this device 16 To completely disconnect this equipment from the mains disconnect the power supply cord plug from the receptacle 17 The mains plug of the power supply cord shall remain readily operable 1601 Jack McKay Blvd Ennis Texas 75119 U S A Telephone 800 321 6699 Fax 800 996 3821 ae ETAsys com
16. uble free protection If damage to the suppression circuitry occurs the AC fault LED will illuminate The ETA S20RT incorporates EVS Extreme Voltage Shutdown to remove AC power from devices plugged into the switched outlets in the event of unsafe high or low voltage conditions A convenient front panel LED indicates if shutdown has occurred The ETA S20RT offers power management control noise filtering and over under voltage and spike surge protection to make it one of the most compact effective power management protection systems on the market today 1601 Jack McKay Blvd Ennis Texas 75119 U S A Telephone 800 321 6699 Fax 800 996 3821 he ETAsys com Specifications are subject to change without notice N ETA ETA S20RT SYSTEMS AC Distribution amp Suppressor Unit Leading by Design KEY FEATURES 9 Total Outlets 6 Rear Panel Switched Outlets 2 Rear Panel Unswitched Outlets 1 Front Panel Unswitched Convenience Outlet Remote Activation via Latched Dry Contact Closure or DC Voltage Remote Status LED Power Terminals Rear Mounted Remote Activation Bypass Switch EPD Emergency Power Down to Incorporate With Fire Control Panels EVS Extreme Voltage Shutdown Clamping Spike amp Surge Suppression Circuitry RFI Noise Filtering to Reduce Radio Frequency Interference EMI Filtering to Reduce Electromagnetic Interference Circuit Breaker Protection 20A Front Mounted USB Charger Light Port Rea
Download Pdf Manuals
Related Search
Related Contents
Manual del usuario La dame de La Sauve - Éditions Vents Salés L`absence des élus à une réunion peut-elle mettre VS-V Standard Manual 821-931 Espan~ol (Espan Motori a benzina MODE D`EMPLOI POUR FAIRE UN CARNET DE VOYAGE I installation instructions commercial washer instructions d`installation User Manual ETIS-VIEW ETIS-EDIT New Jersey ECC Parent Helpline 航 海 仪 器 英 文 讲 义 Copyright © All rights reserved.