1. 110496 1 Motor locked Troubleshooting Replace motor humidity in house Problem Possible Cause Remedy Problem Possible Cause Remedy Failure to No electrical power to Check power Motor cycles 1 Low voltage Check voltage start or no air unit on and off 2 Excessive belt tension 2 Adjust belt tension delivery Fuse blown e Replace fuse 3 Blower shaft tight or Oil or replace bear e Circuit breaker Reset breaker locked ings Unplug unit tripped 4 Bearings dry Oil bearings Electric cord un e Plug in cords or plugged or damaged replace if damaged Noisy 1 Bearings dry Oil bearings Belt too loose or tight Adjust belt tension 2 Wheel rubbing blower 2 Inspect and realign Motor overheated Determine cause of housing Unplug unit overheating 3 Loose parts Tighten loose parts e Belt too tight e Adjust belt tension Blower bearings dry e Oil blower bearings Excessive 1 Inadequate exhaust Open doors or win dows Inadequate Insufficient air exhaust Open windows or air delivery doors to increase air Musty or 1 Stale or stagnate water Drain pan and clean with cooler flow unpleasant in cooler pads running Belt too loose Adjust belt tension or odor 2 Pads mildewed or Replace pads replace if needed clogged Pads plugged Replace pads 3 Pads not wetting Check water distribu properly tion system Inadequate Inadequate exhaust in Open windows or Trough holes e Clean
2. 7 Make sure all the screws re HM om y UE INN moved from the top pan are in place and tighten all screws 8 Skip this step for the RWC35 HAN i Mio amp RN35W models Remove mn ll the three screws 2 in models Fig 11 WC37 amp N37W from each side of the front panel as shown in figure 12 A CAUTION Make sure that you do not remove the bottom most screw It holds the blower housing in place 9 To cover up the gap in the front panel use the two strips of metal obtained from Customer Service Line up the holes in the metal strips to the holes in the front panel and o secure them with the screws pre Do Not Remove viously removed in step 8 See Bonom screw Fig 12 Fig 12 Install the metal strips so that there is no gap between the top pan and the metal strip If there is a gap turn the metal strip around Metal NOTE When mounting a cooler with this type of vertical tunnel configuration the unit should be supported by a flat support or stand The installation method mentioned in the owner s manual using chains and legs should not be used The filler panels in the installation kit may be used to seal off the window above the cooler duct Wiring Diagrams Manual Control Blower Motor Plug Switch ian S Pump TI Motor yu Remote Control Ground Control Blower Motor Screw Ground LockPlate Wire 2 w Grommet T a
3. Quite Los Tornillos Superiores Al ltima Vez No Deja Caer El Conducto 3 D vuelta al conducto 90 gra dos a la izquierda v ase Fig 10 Tenga cuidado cuando da vuelta al conducto que no desconecta ni hace da o a los cables el ctricos que todav a est n conectadas con el control y el panel delantero 4 Inserte el reborde del conducto entre el panel delantero y la tapa Alinee los dos agujeros m s grandes en el conducto con los dos agujeros de centro de la tapa V ase Fig 11 5 Con los tornillos quitados previamente de la tapa ase gure el conducto a la unidad No apriete los tornillos D jenlos flojos hasta que el resto del conducto se ha asegura M do jii 6 Alinee los tres agujeros en el o P fondo del conducto con los I il agujeros en el panel delante NEC ro Con los tornillos quitados Fig 11 del conducto previamente asegure el conducto al panel delantero Alinee A Los Dos Agujeros Medios 7 Aseg rese de que todos los tornillos quitados previamente de la tapa sea en lugar y apriete todos los tornillos 8 Omite este paso para modelos RWC35 y RN35W Quite los tres tornillos 2 en los modelos WC37 y N37W de cada lado del panel delantero seg n lo demostrado en la figura 12 PRECAUCION Aseg rese de que no quite el tornillo m s bajo Este tornillo soporta la caja del ventilador Tira De Metal 9 Para cubrir el abertura en el panel delantero utilice las dos tiras
4. Revise la corriente e Cambie el fusible e Restablecer el cortacircuito e Reemplace el cable Ajuste la tensi n de la correa Determine la causa e Ajuste la tensi n de la correa Lubrique los cojine tes Cambie el motor Sale poco aire cuando la unidad est Insuficiente abertura para que salga el aire Abra las ventanas o las puertas para aumentar el flujo de aire funcionando Poca tensi n en la Ajuste la tensi n o correa cambie la correa Filtros obstruidos Cambie los filtros Enfriamiento El agotamiento del aire Abra m s las ventanas inadecuado es inadecuado O puertas Los filtros no est n mojados e Filtros obstruidos e Filtros agujereados Agujeros de los canales obstruidos Bomba no funciona Revise la distribuci n de agua e Cambie los filtros Acomode la paja en el filtro e L mpielos e C mbiela o limpiela Desconecte la unidad Problema Causa Posible Remedio Motor se apaga Voltaje deficiente 1 Compruebe el voltaje y se enciende Demasiada tensi nen 2 Ajuste la tensi n de la la correa correa Eje del ventilador 3 Lubrique o cambie los atorado cojinetes Desconecte la unidad Cojinetes secos 4 Lubrique los cojinetes Hace Ruido Cojinetes secos 1 Lubrique los cojinetes Rueda roza contra caja 2 Inspeccione y alinee de la rueda Desconecte la unidad Partes sueltas 3 Apri telas Demasiada Insuficiente sali
5. be within 20 feet and in sight of the cooler Aim the remote at the front panel The buttons on the remote control have the same func tions as the buttons on the front panel of the cooler The remote uses two AAA alkaline batteries which are included A holder for mounting on a wall is also included with the unit Open Windows To Exhaust Air An often misunderstood concept of evaporative cooling is the amount of air that should be exhausted How much should you open your windows The fact is that most people do not open their windows enough The following method will help you determine the amount to open your windows Champion Air Balancing Method Take a piece of tissue paper and cut it lengthwise into 3 equal strips 2 Turn your cooler on High Cool 3 Open one window at least six inches wide in each room that you want to cool 4 Take the piece of tissue paper and put it up against the screen of the open window furthest from the cooler discharge opening Let go of it It will do one of three things IF It falls down THEN CLOSE all of the windows one inch and try step 4 again IF It plasters itself to the screen THEN OPEN all of the windows one inch and try step 4 again IF It stays on the screen lightly THEN PERFECT You are done Enjoy your cooler Notes e When switching to Low Cool you must rebalance your home Repeat step 4 e Once you balance your home you can cool some areas more than others by opening those win
6. cooling house doors to increase air clogged flow Pump not working e Replace or clean Pads not wet Check water distribu properly pump Unplug tion system unit e Pads plugged e Replace pads e Open spots in pads e Repack pads Water drain 1 Float arm not adjusted Adjust float Trough holes clogged Pump not working properly e Clean trough and unplug holes e Replace or clean pump Unplug unit ing from cooler properly 2 Overflow assembly leaking Tighten nut and overflow pipe Limited Warranty This warranty is extended to the original purchaser of an evaporative cooler installed and used under normal conditions It does not cover damages incurred through accident neglect or abuse by the owner We do not authorize any person or representative to assume for us any other or different liability in con nection with this product Terms And Conditions Of The Warranty For Eight Years from date of purchase we will replace the original base assembly if water leakage should occur due to rust out For One Year from date of purchase we will replace any original component provided by Champion Cooler which fails due to any defect in material or fac tory workmanship only Exclusions From The Warranty We are not responsible for replacement of cooler pads These are disposable components and should be replaced periodically We are not responsible for any incidental or consequential damage resulting from
7. season depending upon the length of the season At the beginning and at mid season a clean pad is more absorbent and efficient and will deliver substantially more cool air Winter Shut Down Drain water Always drain all of the water out of the cooler and water supply line when not in use for prolonged periods and par ticularly at the end of the season Keep the water line disconnected from both the unit and water supply so that it does not freeze e Cover unit To protect the life of the finish a cover for the unit is suggested in extended periods of non use e Cover grill To help keep out cold air you can use the optional plastic grill cover This cover may be purchased from your local distributor To install the cover line up the grill cover with the grill so that the tabs on the cover will slide over the center section of the grill Slide the grill cover onto the grill The tabs will snap into place To remove just pull the grill cover straight forward away from the grill e Unplug unit from power supply during extended periods of non use By following the operating installation and maintenance suggestions as outlined you can get many years of efficient and satisfactory service from your cooler In the event additional information is desired your dealer will be more than glad to assist you in every possible way Vertical Duct Conversion This window unit can be reconfigured to a vertical tunnel con figuration for ins
8. Ponga en marcha a su enfriador a High Cool 3 Abra una ventana por lo menos seis pulgadas de ancho en cada sitio que usted desee refrescar 4 Tome un pedazo de papel de seda y p ngalo contra la pantalla de la ventana abierta m s lejos de la apertura del enfriador Su ltalo al papel de seda Har una de tres cosas SI Se caiga ENTONCES CIERRE todas las ventanas una pulgada e intente el paso 4 otra vez SI Se queda contra la pantalla con fuerza ENTONCES ABRA todas las ventanas una pulgada e intente el paso 4 otra vez SI Se queda ligeramente contra la pantalla ENTONCES PERFECTO Se ha acabado Goce del aire refres cante NOTAS Al poner el enfriador a Low Cool usted debe reequilibrar el aire de su hogar Repita el paso 4 e Al equilibrar el aire de su hogar usted puede refrescar algunas reas m s que otras abriendo esas ventanas m s y cerrando las otras por la misma cantidad Repita el paso 4 Asegurarse de que el aire de su hogar sea equilibrado Instalaci n Instalar Las Patas NOTA Si instale la unidad sin el uso del equipo de instalaci n omite las direcciones siguientes y las de la figura 2 e Quite los tornillos de la esquina de la bandeja A fig 1 SS Ss SN e Coloque la m nsula en la esquina de la bandeja usando los dos agujeros de la parte superior de la m nsula B fig 1 y los dos tornillos que antes habia quitado e Coloque la m nsula del otro lado de la misma
9. any malfunction We are not responsible for any damage received from the use of water softeners chemicals descale material plastic wrap or if a motor of a higher horsepower than what is shown on the serial plate is used in the unit We are not responsible for the cost of service calls to diagnose cause of trouble or labor charge to repair and or replace parts For limited warranty to be valid the evaporative cooler must be maintained per the Maintenance Section of this manual How To Obtain Service Under This Warranty Contact the Dealer where you purchased the evaporative cooler If for any reason you are not satisfied with the response from the dealer contact the Customer Service Department 5800 Murray Street Little Rock Arkansas 72209 1 800 643 8341 Email info championcooler com This limited warranty applies to the original purchaser only 110496 1 General Specifications Especificaciones Generales Weight Ibs Cabinet Dimensions in Window Opening Req d in Model No Peso libras Dimensions De La Caja pulgadas Abertura Requerida pulgadas Modelo Dry Operating Height Width Depth Width Height Seco Lleno Altura Anchura Profundidad Anchura Altura RWC35 RN35W 30 1 2 WC37 N37W 33 7 16 WC44 N44W 34 1 2 WC46 N46W RWC46 RN46W WCS0 NSOW RWCS50 RNSOW 34 1 2 Motor Specifications Especificaciones Del Motor Model No Motor Part Speed Volts Motor Pulley Pa
10. cuando posible Esta baja velocidad del ventilador permite que el aire se queda m s de largo en los filtros mojados y de tal modo produce un aire m s fresco Los posiciones HIGH VENT y LOW VENT Ajuste el interruptor a la posici n HIGH VENT alta o LOW VENT baja para poner en marcha el ventilador a una alta o baja velocidad sin la bomba Este es til en noches frescas o cuando se desea un ventilador solamente Para Las Unidades De Control A Distancia Estas unidades pueden ser controladas con los tres botones en la rejilla por delante del enfriador o con el mando a distancia El Bot n PUMP Al presionar este bot n pondr en marcha y apagar la bomba Cuando est iluminada la luz LED la bomba est en marcha Para mejor resultado ponga en marcha la bomba por unos cuantos minutos para mojar los filtros antes de poner en marcha el ventilador Para tener aire fresco debe poner en marcha la bomba mientras el ventilador est en marcha Se puede apagar la bomba cuando se desea un ventilador solamente El Bot n FAN Este bot n controla el ventilador Al presionar este bot n cuando el ventilador est apagado pondr en marcha el ventilador a alta velocidad La segunda prensa pondr en marcha a baja velocidad y la prensa siguiente apagar el ventilador Hay luces LED por el frente del control que indica en cual estado est el ventilador alta velocidad baja velocidad o apagado ninguna luz LED iluminada Nota Habr un
11. de metal obtenidas del servicio de cliente Alinee los agujeros en las tiras de metal a los agujeros en el panel delantero y aseg relos con los tornillos quitados previa mente en el paso 8 V ase fig 12 Instale las tiras de metal de y No Quite El modo que no haya abertura entre Tomillo M s ornilo as Fig 12 la tapa y la tira de metal Si hay Bajo una abertura d vuelta a la tira de metal alrededor NOTA Al montar un enfriador con este tipo de configuraci n con el conducto vertical debe soportar la unidad con un soporte o plataforma plana El m todo de instalaci n mencionado en este manual usando cadenas y las patas no debe ser utilizado Los paneles del relleno en el kit de instalaci n se puede utilizar para aislar la ventana arriba del conducto del enfriador Esquemas Del Cableado Control Manual Motor De La Rueda Enchufe Interruptor Blanco 110496 1 Pasahilo Control A Distancia Tornillo Control Motor De De Tierra p La Rueda Cal ble De Placa De Negro Fijaci n Con Blanco al Mi 11 Problema No arranca o no sale aire Causa Posible No llega corriente Fusible fundido e Cortacircuito desac tivado e Cable el ctrico da ado Correa muy floja o apretada Motor recalentado Correa muy apretada e Cojinetes de la rueda est n secos Motor parado La Localizaci n De Aver as Remedio
12. manera Fig 1 e Vea la instrucci n abajo de Ajuste las patas para ajustar las patas SS SS Instalar El Enfriador Z PRECAUCION La superficie en que ha de colocarse el enfriador deber aguantar el peso completo de la unidad cuando sta est en funcionamiento Para saber este peso vea la tabla de especificaciones Z PRECAUCION No conecte el enfriador hasta que la ins talaci n est completa y se haya comprobado la estabilidad del mismo 110496 1 Quite todas las rejas de los costados e Fije los ganchos en la pared Ponga los dos ganchos para la cadena arriba del cuello del enfriador separados por una distancia equiva lente al ancho de la unidad A fig 2 Enganche una xe cadena en cada gancho y luego enganche un gan A cho S en cada cadena p cae NOTA Los ganchos que B vienen con sta unidad tienen rosca de tornillo Cuello para madera y son para E uso en paredes de madera E Las paredes de concreto o ladrillo requieren el uso de tuercas mariposas de suficiente fuerza o anclas con ganchos de acopla mientos Instale las guardas de retenci n Coloque dos guardas de retenci n Guarda De en la parte inferior de Retenci n la pesta a del cuello y Superior aj stelas al ancho de la ventana Corte las guardas si es necessario stas sujetan a los pane les de relleno fig 3 Fig 3 Guar
13. retardo de dos segundos entre una prensa del bot n y la operaci n del ventilador El Bot n ON OFF Al presionar este bot n mientras est encen dido el ventilador o la bomba apagar todo Al presionarlo otra vez mientras este apagado volver el ventilador y la bomba a sus estados de funcionamiento anteriores Cuando primero enchufe el enfriador o despu s de que la electricidad se haya interrumpido presionando el bot n On Off encender el enfriador a su estado por defecto lo cual est con la bomba encendido y el ventilador en el estado de alta velocidad e El Mando A Distancia Al funcionar el enfriador con el mando a distancia debe estar no m s de 20 pesados a distancia y en la vista del enfriador Apunte el mando a distancia al frente del enfriador Los botones del mando a distancia tiene las mismas funciones que los botones en el frente del enfriador El mando a distancia utiliza dos acumuladores alcalinos incluidos de AAA Un sostenedor para montar en la pared tambi n se incluye con la unidad 110496 1 Cuanto Debe Abrir Las Ventanas Un concepto a menudo entendido mal de enfriamiento por evapora ci n es la cantidad de aire que debe ser agotada Cu nto debe usted abrir sus ventanas El hecho es que la mayor a de la gente no abre sus ventanas bastante El m todo siguiente le ayudar El M todo De Champion De Equilibrar El Aire 1 Tome un pedazo de papel de seda y c rtelo a lo largo en 3 tiras iguales 2
14. 044 10400 10403 10401 14 110829 310586 322008 001 PEEP WFP ENN RPE Ee Not included with unit Call 1 800 643 8341 to obtain this part at no additional cost No incluido con la unidad Llame 1 800 643 8341 para obtener esta parte sin coste adicional NOTE Standard hardware items may be purchased from your local hardware store NOTA Articulos de uso corriente pueden comprarse en la ferreteria de su localidad 110496 1 Lea y Conserve Estas Instrucciones Reglas De Seguridad 1 Lea las instrucciones con cuidado 2 Launidad debe estar Apagada y Desconectada de la electricidad cuando se instale o haga cualquier mantenimiento 3 Su enfriador funciona s lo con corriente alterna de 120 voltios 60 Hz ciclos 4 El motor y la bomba est n conectados con la tierra y se apagar n autom ticamente en caso de sobrecalentamiento Los motores volver n a funcionar cuando se enfr an 5 Enchufe una bomba del enfriador evaporativo solamente y nada m s al recept culo de la bomba Z ADVERTENCIA Para reducir el riesgo de incendio o toques el ctricos no use este ventilador con ning n dispositivo de estado s lido para controlar la velocidad del ventilador Enfriamiento Por Evaporaci n El enfriamiento por medio de evaporaci n es la manera de la natu raleza de refrescarse Cuando el aire se mueve sobre una superficie mojada se evapora el agua y se absorbe el calor Al salir de una piscina con el viento qu
15. 182 110351 2 110274 110211 110445 110271 314003 001 314005 001 FL C 218001 031 281001 001 110436 110714 310716 3D 2 110574 3 30A 1 3HL 1 2 310811 2 110599 4 110603 2 1103647 1103754 110425 110839 006 222006 001 222007 001 110839 1 110839 2 322007 004 1104004 1104034 110401 14 110829 310586 322008 001 Optional accessories Must be purchased separately Accesorios opcionales Debe comprarlos por separados WC44 N44W 222905 001 222903 006 324006 106 2 226003 001 2 110094 2 3PW 3 6 324007 205 226003 002 110098 3PW 5 3 224003 032 224003 047 224103 006 322120 001 324103 007 15BW 110182 110351 2 110275 110215 110445 110272 314003 025 314005 001 FL C 218001 031 281001 001 110436 110714 310716 3D 3 110574 3 30A 1 3HL 1 2 310811 2 110599 4 10603 2 10364 10375 10425 10839 006 22006 001 22007 001 10839 1 SNA ama 110829 310586 322008 001 WC46 N46W RWC46 RN46W WC50 NSOW RWC50 RNSOW 220901 003 220902 002 324007 205 3 226003 002 3 110098 3 3PW 5 9 See Vea 3 224003 032 224003 047 224105 004 322120 001 324105 006 16BW 110183 110351 2 110275 110215 314003 024 314005 001 FL C 218001 031 281001 001 110436 110714 310716 3D 10 110574 6 30A 1 3HL 1 2 310811 2 110599 4 10603 2 103724 10375 104254 10839 006 22006 001 22007 001 10839 1 10839 24 22007 0
16. 25 Float Valve V lvula Del Flotador cioionmommmmmmmsmmnms FL C 26 Pump Mount Montura De La BOmb G cscceccscsseseeessessessessessssssessessesssssesesseseessesessesnensenees 222175 005 27 Pump Screen Malla Para La Bomba orreee AE EAA 281001 001 2870 PUMP A BOM A RA 110436 29 Pump Retainer Sujetador De La Bomba iececccsssessessssessessessesesesessessssessessesseseesesesnesnenees 110714 31 Tube Water Delivery Tubo De Agua ssssssssss ssssssesssrsssssssssssssssrserssssssnrssstresssssnnnserrrensnnssne 310716 33 Water Distributor Assembly Sistema Del Distribuidor De AgUl ccciinininnmnmmmmmm 3D 15 34 Holder Water Distributor Soporte Para El Distribuidor De Agua sses 35 Over Flow Assembly Montaje De Desagiie c c cccsscsssssssessssesesssessesesessssesesseseasssensesenees 30A 1 36 House Leg Collar Assembly Montaje De Collar De La Pata 9 3HL 3 2 Bde CATIA A A A ROO 310811 2 38 Retainers Window Panels Guarda De Retenci n Para Los Paneles nsss 110599 4 39 Window Panels Paneles De Relleno Para La Ventana nosses 110603 2 40 Electrical Cord Motor Cable El ctrico Del Motor w cccccscccscsssssssssesesessssessseseseesseseseseseeseees 41 Wiring Harness Cableado El ctrico CS NAM A 0 RR ENS ET ETT RN 43 Knob Switch Perilla Del Interruptor cececccececccsssssscssesesesesesesesecesessseseseeeueseneseseeeaeeeenensees 44 Switch Box Caja Para El Interruptor 45 Loc
17. CHAMPION ESSICK Window Evaporative Cooler Manual Manual Control Units WC37 N37W WC44 N44W WC46 N46W WCS50 NSOW Remote Control Units RWC35 RN35W RWC46 RN46W RWCS50 RN50W Circle the model of your cooler and record the serial number below Encierre con un circulo el modelo de su enfriador y escribe el n mero de serie abajo Serial N mero De Serie Ww indow Uni ts I Convertible Kit Not Shipped With Cooler Available Upon Request At No Additional Cost owt Read Carefully All Of This Manual Before Installing The Unit Lea Con Cuidado Todo Este Manual Antes De Instalar La Unidad Read And Save These Instructions Vea el Espa ol en el interior Evaporative Cooling Evaporative cooling is nature s way of cooling When air is moved over a wet surface water is evaporated and heat is absorbed When stepping out of a swimming pool with the wind blowing evaporative cooling makes you feel cool even though the air may be warm The human body itself is cooled primarily by the evaporation of perspiration This unit works on the same principle Air is drawn across wet filter pads where the air is cooled by evaporation and then circulated throughout the building It is this combination of cooled air and the movement of air over the skin which makes it feel cool Unlike refrigeration systems which recirculate the air an evapora
18. E Additional anchors can be purchased at your local hardware store for an choring in other types of materials such as concrete or brick 110496 1 e Install window panel retainers Place two panel retainer strips onto bottom of neck flange and position to the width of the window Cut the strips to fit if necessary These strips hold the window fill in panels Fig 3 Top Panel Retainer Bottom Panel Retainer Position cooler in win dow Position neck of cooler so that bottom of neck flange rests on window sill and flange E Fig 2 is snug against edge of sill H Fig 2 With cooler in position hook the S hooks into the holes of the top pan near the back of the cooler B Fig 2 Break fill in panels to fit With cooler installed as described above measure for each window fill in panel and score with sharp knife and straight edge guide to desired width To break window fill in panels the panel should be laid over the edge of a straight flat surface at the point to be broken off Apply pressure on the edge of the panel that extends over the edge of the surface and break off unwanted piece Install fill in panels Place one window fill in panel on each side of grill and into panel retainer strip at bottom of grill Place the other panel retainer strips onto top of neck flange and fill in panels Be sure the panels are snug up against cooler neck Place window beh
19. an be accomplished by Fig 6 bending the float rod Fig 6 Maintenance WARNING Before doing any maintenance be sure power is off and unit is unplugged This is for your safety Spring Start Up e Oil bearings The blower bearings and cooler motor in this unit should be oiled with a few drops of non detergent 20 30 weight oil once each year The motor does not need oil if it has no oil lines for oiling Motors that have no oil lines are lifetime oiled at the factory and require no further oiling for the life of the unit ACAUTION Do not over oil Over oiling can cause motor burn 3Lb out due to excessive oil getting into 3 4 Inches motor winding Check belt tension A 3 lb force should deflect the belt 3 4 inches see Fig 7 Readjust belt if needed Clean pump Cleaning the pump is necessary once a year at start up For your safety turn unit off and unplug from power receptacle Remove the pump from the mount slot Remove the base of the pump as shown in Fig 8 Clean the pump and turn the impeller to ensure free operation Remove the pump spout and check for any blockage After cleaning reinstall the base onto the pump Press firmly to make sure it is secure Reattach the pump to the mount in the cooler using the plastic retainer to ensure that the pump will not overturn Do not forget to replace the spout and water delivery tube onto the pump outlet Replace Pads Aspen pads should be replaced once or twice a
20. bierta alinee la cubierta con la rejilla de modo que los clips de la cubierta se deslizar n sobre la secci n de centro de la rejilla Deslice la cubierta sobre la rejilla Los clips de la cubierta se encajar n a presi n hacia lugar Para quitar d un tir n con cuidado a la cubierta quit ndola derecho adelante de la rejilla Si usted sigue estas sugerencias en cuanto a instalaci n operaci n y mantenimiento podr disfrutar de muchos a os de servicio eficiente y satisfactorio de este enfriador Si desea m s informaci n su con cesionario tendr mucho gusto en ayudarle con respecto a cualquier duda o pregunta 110496 1 Conversion Al Conducto Vertical Esta unidad se puede configurar de nuevo a una configuraci n con el conducto vertical para la instalaci n en una abertura m s peque a de la anchura Siga los pasos subsecuentes si se desea esta configuraci n Nota Los tiras de metal usados para convertir el t nel no se env a con esta unidad Si desea se puede llamar el servicio de cliente a 1 800 643 8341 para obtenerlos sin coste adicional 1 Quite los 9 tornillos de ambos lados y del fondo del conducto 2 Quite los 4 tornillos medios de la tapa mientras que soporte el conducto en lugar V ase Fig 9 Tenga cuidado de no dejar caer el conducto o los da os a los ca bles el ctricos podr an ocurrir Puede ne cesitar aflojar otros tornillos en la tapa para hacerla m s f cil Fig 9 quitar el conducto
21. da De Reten ci n Inferior Coloque el enfriador en la ventana Coloque el cuello del en friador dentro de la ventana para que la parte inferior de la pesta a del cuello se asiente en la repisa de la ventana y la pesta a E fig 2 se ajuste contra el borde de la repisa H fig 2 Con la unidad situado en la ventana enganche los ganchos S en los agujeros encontrado en la esquina trasera superior del enfriador B fig 2 Rompa los paneles de relleno Con el enfriador instalado seg n el m todo de arriba mida el ancho requerido para cada panel Marque el panel con un cuchillo filoso y una regla al ancho correcto Apoye el panel en el borde de una superficie lisa y plana y presione sobre la parte del panel que se extienda sobre el borde de la superficie para que se desprenda la parte sobrante Instale los paneles de relleno Coloque un panel de relleno a cada lado de la rejilla y dentro de la banda de retenci n situada en la parte inferior de la rejilla Coloque las otras guardas de retenci n en la parte superior de la pesta a del cuello y los paneles de relle no Compruebe que los paneles queden bien ajustados contra el cuello Coloque la ventana detr s de la guarda de retenci n Levante la parte trasera del enfriador para que la ventana D fig 2 pueda bajarse y quedar detr s de la parte superior de la guarda de retenci n C fig 2 Nivele el enfriador Ajuste las cadenas hasta que el enfriador est nivel Ajuste
22. da de 1 Abra las puertas o las humedad en la aire ventanas casa Olor a ence Agua estancado en la 1 Desagiie y limpie los rrado olor unidad filtros desagradable Los filtros tienen moho 2 Cambie los filtros o son obstruidos Los filtros son secos 3 Revise la distribuci n de agua e Agujeros del canal e Limpielos tapados Bomba no trabaja Reemplace o limpie adecuada la bomba Desco necte la unidad El agua est El flotador no se ajusta 1 Ajuste el flotador drenando del correctamente enfriador El montaje de desagiie 2 Apriete la tuerca y el se est escapando tubo de desagiie Exclusiones De La Garant a No somos responsables por reemplazar los filtros del enfriador Estos son componentes desechables y deben cambiarse peri dicamente No somos responsables por da os que resulten a consecuencia de alguna falla de funcionamiento Garant a Limitada T rminos y Condiciones De La Garant a Durante Ocho A os a partir de la fecha de compra nosotros reemplazaremos la base original del enfriador en caso de que goteara agua debido a oxidaci n Como Obtener Servicio Bajo Esta Garant a P ngase en contacto con el Concesionario que le vendi el enfriador Si por alguna raz n usted no queda satisfecho con la respuesta por parte del Concesionario comun quese con el departamento de servicio al cliente 5800 Murray Street Little Rock Arkansas 72209 1 800 643 8341 info championcooler com Esta garant a limitada s
23. dows more and closing the others by the same amount Repeat step 4 to make sure your home is still air balanced Cooler Installation Installing House Legs NOTE If installing unit without the use of the installation kit omit these directions and those pertaining to Fig 2 Remove two corner screws in the bottom pan A Fig 1 Place the house leg bracket in the LN corner of the bottom pan using the SS lt two top holes in the bracket B Fig 1 Replace the two previously removed screws to hold the house leg bracket in place As shown by dotted house leg bracket e Refer to the instructions Adjust house legs below for adjusting the house legs Mounting Cooler CAUTION Make sure that the mounting surface is strong enough to support the operating weight of the cooler when in use For operating weight see Specification Table CAUTION Never plug in cooler until installation is complete and unit has been tested for rigidity Lift out all removable louvered sides e Screw chain hooks into window facing Position the two chain hooks above the neck of the cooler a distance equal to the width of the cooler wae apart A Fig 2 Hook one hanger chain in each a eae hook and then one S D hook in the other end of c it B each chain N NOTE The chain hooks Window supplied with this mount es ing kit are for use in wood
24. e aplica al comprador original solamente Para que la garant a limitada sea v lida se debe mantener el enfriador evaporativo seg n la secci n de Mantenimiento en este manual La presente garant a se extiende al comprador original de un enfriador evaporativo instalado y utilizado bajo condiciones normales No cubre da os ocurridos por accidente descuido o abuso por parte del propietario No autorizamos que ninguna otra persona o representante asuma por nosotros cualquier otra o dife rente responsabilidad en relaci n con este producto Durante Un A o a partir de la fecha de compra reemplazaremos cualquier componente original proporcionado por Champion Cooler que falle debido a cualquier defecto de material o mano de obra en la f brica solamente No somos responsables por cualquier da o producido por el uso de suavizadores de agua productos qu micos materiales desincrustantes envolturas de pl stico O si se usa en esta unidad un motor de mayor potencia de la que se indica en la placa de n mero de serie No somos responsables por el costo del servicio para diagnosticar la causa del problema ni por la mano de obra necesaria para reparar y o reemplazar piezas 12 110496 1
25. e sopla usted se siente fresco aunque el aire puede ser caliente El cuerpo humano s mismo es refrescado principalmente por la evaporaci n del sudor Este enfriador funciona usando el mismo principio El aire se traza a trav s de los filtros mojados donde el aire se enfr a por medio de evaporaci n y despu s circula a trav s del edificio Se hace fr o de la sensaci n cuando tiene esta combinaci n del aire enfriado y del movimiento del aire sobre la piel A diferencia de los acondicionadores de aire que recirculan el aire un enfriador evaporativo trae continuamente por dentro el aire fresco mientras agota el aire viejo Se reemplaza completamente el aire cada 2 a4 minutos abriendo las ventanas o las puertas o una combinaci n de ambas El aire es siempre fresco no es viciado cargado de humo y olores como ocurre con los sistemas de aire acondicionado a base de refrigeraci n Operaci n Para Las Unidades De Control Manual e La posici n PUMP El interruptor tiene seis posiciones Ajuste el interruptor a la posici n PUMP bomba para poner en marcha la bomba sin el ventilador Para mejor resultado ponga en marcha la bomba por unos cuantos minutos para mojar los filtros antes de poner en marcha el ventilador Los posiciones HIGH COOL y LOW COOL Ajuste el interruptor a la posici n HIGH COOL o LOW COOL para poner en marcha el ventilador a una alta o baja velocidad junto con la bomba Ajuste el interruptor a la posici n LOW COOL
26. er in the wet pads and therefore increases it s cooling efficiency High and low vent settings The High Vent and Low Vent settings operate the blower without the pump This is useful on cool nights or at times when just a fan is desired Remote Control Units These units may be controlled using the 3 buttons on the front panel of the cooler or with the remote control e PUMP button Pressing this button toggles the pump on and off When the LED is lit the pump is running For best results turn on the pump for a few minutes to wet the pads before operating the fan The pump must be on while operating the fan for cooling You may also want the pump turned off at times when just a fan is desired FAN button Pressing this button will cycle the fan through High Speed Low Speed Off The LED s on the front of the control indicate wether the fan is on high speed low speed or off no LED s lit Note There will be a 2 second delay between a button press and the operation of the fan ON OFF button Pressing this button while the pump or fan is on will turn everything off Pressing it again while in the off state will return the fan and pump to their previous operating settings When first plugging in the cooler or after power has been interrupted pressing the On Off button will start the cooler in the default state which is with the pump on and the fan on high Remote Control To operate the cooler with the remote you must
27. ind retainer strip Raise back of cooler so that the window D Fig 2 may be brought down behind top of panel retainer strip C Fig 2 Level Cooler Adjust the chains to level the cooler Adjust house legs Pull out house legs so that the rubber bumpers rest against house siding F Fig 2 Tighten screw in retaining collar G Fig 2 Connecting Water e Install overflow assembly Remove nut and place nipple through the hole in the pan with the rubber washer between the pan and the head of the drain nipple Fig 4 Screw on nut and draw up tight SNA Bottom Pan against bottom of pan Insert overflow Nut pipe in nipple to retain water Overflow Fig 4 pipe may be removed to drain pan when necessary A garden hose may be Overflow Pipe S Nipple Rubber Washer screwed on the drain nipple to Faucet 7 a drain water away from your unit Rat 523 H 3 3 ES ES iz Connect water supply line In stall a sillcock and water valve on faucet as shown by figure 5 Place the nut and ferrule on the tubing Sillcock AY Sa and tighten the nut until water tight 110496 1 Water Supply Line gt Corner Post ou A Float Rod Install float valve Install valve in the provided hole in corner post Fig 6 and attach water supply line Fill pan Allow water to fill to within 1 of the top of the overflow pipe and adjust float to maintain this water level This c
28. kplate Manual Units Placa De fijaci n Unidades De Control Manual onincnininin 46 Grill Assembly Maunual Units Rejilla Completa Control Manual 46a Grill Assembly Remote Units Rejilla Completa Control A Distancia 110839 23 47 iLockplate amp Grommet Remote Units Placa De fijaci n Con Pasahilo Control A Distancia 322007 0043 48 Electronic Control Assembly Montaje De Control Electr nico ssc 1104004 49 Dress Ring Anillo Decorativo w e ccccesssssssssessesesessessssesessssesesesseseensasenescsseseassseneaeensseaeaneaeee 1104034 50 Remote Control Mando A Distancia cccccccccccsssccsssssssessssescsesesssssscseseseucecesesesessesceesesesseeesesees 110401 1 51 Grill Cover Cubierta Para La Rejilla oonnninininnnnnnnnmmmmrrs 110829 52 Bleed Off Kit Equipo De La V lvula De Desahogo 310586 53 Mount Strips For Vertical Tunnel Tiras De Metal Para El Conducto Vertical 708048 54 Blower Brace Soporte Para La Caja De La Rueda oooinnnicinnininnnnnmnmmmrs 222175 003 2 See motor specification table Vea la tabla de especificaciones del motor For Manual Control units Para las unidades de control manual For Remote Control units Para las unidades de control a distancia WC37 N37W 222903 001 222904 003 324006 303 3 226003 001 3 110091 3 3PW 3 9 See Vea 3 224003 022 224003 046 224106 007 322120 001 324104 009 12BW 110
29. las patas Saque las patas F fig 2 para que los topes de hule descansen contra el costado de la pared Apriete el tornillo del collar G fig 2 Conectar El Agua e Instale el montaje de desagiie Quite la tuerca y pase la boquilla por el agujero de la bandeja colocando la arandela de goma entre la bandeja y la cabeza de la boquilla fig 4 Coloque la tuerca en la boquilla y atorn llela hasta que quede apretada contra la parte inferior de la bandeja Inserte el tubo de desagiie en la boquilla para retener el agua El tubo de desagiie se puede quitar para desaguar el agua de la bandeja cuando sea necesario Se puede conectar una manguera de jard n a la boquilla para desaguar el agua hacia otra parte f Tubo De Desag e Boquilla Roscada S Arandela De Goma Sj Bandeja S Tuerca Fig 4 Conecte el tubo de abasteci miento de agua Instale la llave de paso y la v lvula de agua en el grifo de agua seg n indica la figura 5 Coloque la tuerca y la f rula en el tubo y apriete bien la tuerca para impedir que gotee el agua Instale la v lvula del flotador Instale la v lvula en el agujero que se encuentra en el poste de esquina fig 6 y conecte el tubo de agua Tubo De Abastec imiento De Agua Poste De Esquina NN Q Llene la bandeja con agua Permita que se llene la ban Varilla Del deja con agua hasta una altura Flotador de una pulgada por debajo del 23838 borde superio
30. r de la bandeja 358 y ajuste el flotador para que E RER mantenga este nivel Esto se puede lograr torciendo la Fig 6 varilla para arriba o para abajo fig 6 Mantenimiento LADVERTENCIA Antes de hacer cualquier mantenimiento compruebe que la unidad est apagada y desconectada de la electricidad Esto es por su seguridad Puesta En Marcha En La Primavera Cambie los filtros Debe cambiar los filtros de paja una o dos veces durante cada temporada seg n la duraci n de sta Al principio y a mediados de la temporada un filtro limpio es m s absorbente y eficiente y producir un mayor volumen de aire fr o 10 Limpie la bomba Es necesario limpiar la bomba una vez al principio de cada a o Por su propia seguridad apague la unidad y descon ctela de la electricidad Quite el sujetador de pl stico de la montura y jale la bomba desliz ndola hacia usted Quite la base de la bomba seg n se muestra en la figura 7 Limpie la bom Quite ba D le vuelta a la h lice La Base para verificar que se mueve libremente Quite el pico de la bomba y vea si est obstruido Despu s de limpiar reinstale A la base en la bomba Presiona X J firmemente para asegurarse de que es segura Vuelva a colocar la bomba en la unidad y f jela en su montura con el sujetador de pl stico Esto impedir que se caiga la bomba al agua lo que da ar a el motor No se olvide de volver a conectar el tubo de agua a la bomba Lub
31. rique los cojinetes Los cojinetes de la rueda y el motor del ventilador deben ser lubricados usando unas gotas de un aceite no detergente de densidad 20 30 una vez al a o No obstante los motores sin tuber as para aceite no necesitan ser lubricados Estos motores son lubricados en la f brica de por vida y no requieren nunca ninguna lubricaci n PRECAUCION No lubrique dem s El agregar demasiado aceite puede ocasionar que se queme el motor a causa del aceite entrando al interior del motor 3 Libras e Compruebe la tensi n de la co 3 4 Pulgadas rrea Una fuerza de 3 libras debe desviar la correa 3 4 pulgadas v ase fig 8 Ajuste la correa si es necesario Preparar La Unidad Para El Invierno Drene el agua Drene siempre toda el agua de la unidad y del tubo de abastecimiento de agua cuando no use el enfriador durante pe r odos prolongados especialmente al fin de la temporada El tubo debe quedarse desconectado del enfriador y del abastecimiento de agua para que no lo congele Cubra la unidad Para proteger y alargar la vida til del acabado se sugiere cubrir el enfriador durante per odos largos cuando no sea utilizado Desconecte la unidad de la electricidad cuando no sea utilizada durante per odos extendidos Cobra la rejilla Para ayudar a guardar el aire fr o de entrar en la casa usted puede utilizar la cubierta pl stica opcional Se puede comprar la cubierta de su distribuidor local Al instalar la cu
32. rt Drive Belt Part Modelo Motor N Velocidad Voltios Polea Del Motor N Banda N RWC35 RN35W 110442 110271 110226 4L 480 WC37 N37W 110445 110271 110211 4L 450 WC44 N44W 110445 110272 110215 4L 560 WC46 N46W RWC46 RN46W WCS0 NSOW RWCS50 RNSOW 110445 110272 110215 4L 560 110447 110273 110215 4L 560 Rs s sye 26 RWC35 RN35W 6 110496 1 Replacement Parts List Lista De Piezas De Repuesto When ordering parts please be sure to furnish the following information on all orders Failure to do so may delay your order Al pedir piezas incluya toda la informaci n siguiente con su pedido El no proporcionar toda esta informacion resultar en una demora 1 Cooler Model No Modelo de la unidad 2 Cooler serial number N mero de serie de la unidad 3 Description and part number Descripci n y n mero de pieza 4 Date of purchase Fecha de compra No RWC35 N Description Descripci n RN35W 1 Top PA OO eran A dd 322175 001 De Bottom Pan Base De La CAJA ooonioicinninioninnininnncrcr errar 222175 002 3 Louvered Side Assembly Montaje De Reja Lateral sssri 324006 107 2 4 Water Trough Side Canal De Agua Lateral 226004 001 2 5 Aspen Pads Side Filtros De Paja Lateral sessssssessesesseesesesrirerirrrissrerssrrssrrsssrrssrrrssrres
33. s 110084 2 6 Pad Retainer Side Soporte Para El Filtro Lateral oonnninicninvninnnmmmmrmrr 3PW 16 6 Ze Louvered Back Assembly Montaje De Reja Posterior sssri 324006 108 8 Water Trough Back Canal De Agua PosteriOT ooininininninninnmmnmrrs 226004 002 9 Aspen Pads Back Filtros De Paja PoSteriOT oonnnninninmmmmmnimmarnrrrs 110083 10 Pad Retainer Back Soporte Para El Filtro PosteriOF oninninicninvnvnvommmmmmrmmm 3PW 15 11 Corner Post With Float Hole Poste De Esquina Con Agujero Para Flotador 224018 002 12 Corner Post For Pump Mount Poste De Esquina Para Montar La Bomba wmimoo 224018 001 13 Front Panel Panel Delantero aa aaa 224175 001 14 Tunnel T nel Cuello Del Enfriado oonininninininnmmnmmmnnrrrrrs 322120 001 15 Blower Housing Caja De La Ruedar rosse KE REER ORAE 324175 002 16 7 Blower Wheel A RUCUG van O E andate 110765 17 Shaft Blower Wheel Eje De La Rueda 110179 18 Bearings Blower Wheel Shaft Cojinetes Del Eje De La Rueda 110351 001 2 19 Pulley Blower Wheel Polea De La Rueda wiceccsescccessssssesssssesssssssessssssessessesseseesessesnesnenees 110270 20 Drive Belt Correa 110226 PR A A NS NA 110442 22 P lley Motor 7 Polea Del MOtor visor oa isa 110271 23 Motor Mount Montura Del Motor 320175 001 24 Motor Mount Clips Seguros Para Montar Motor ccscscssessssesssessesssssssessessesseseeessessessenees 314005 001
34. tallation into smaller width openings Follow the subsequent steps if this is desired Note Tunnel mount strips used to convert tunnel are not shipped with this cooler If desired call Customer Service at 1 800 643 8341 to have it shipped to you at no cost Remove top screws last Do Not Drop Tunnel 1 Remove the 9 screws from the sides and bot tom of the tunnel 2 Remove the top 4 mid dle screws of the top pan while holding the tunnel in place Fig 9 Be careful not to drop the tunnel or damage to the electric cords i could occur You may Fig 9 need to loosen other screws in the top pan to make it easier to remove the tunnel 3 Rotate the tunnel 90 degrees counter clockwise Fig 10 Be care ful as you rotate the tunnel that you don t damage or disconnect the cords which are still connected to the controls and the front panel 4 Insert the flange of the tunnel between the front panel and the top pan Line up the two larger holes in the tunnel with the center two holes of the top pan Fig 11 5 Using the screws taken from the top pan secure the tunnel to the unit Do not tighten the screws leave them loose until the rest of the tunnel has been secured 6 Line up the three holes at the bottom of the tunnel with the holes in the front panel Using the screws taken from the bottom of the tunnel pre viously secure the tunnel to the front panel Fig 100 2 Line up to the two middle holes
35. tive cooler continually brings in fresh air while exhausting old air You are completely replacing the air every 2 to 4 minutes by opening windows or doors or a combination of both The air is always fresh not stale laden with smoke and odors as happens with refrigerated air conditioning 110496 1 Safety Rules 1 Read these instructions carefully 2 Unit must be in the Off Position and Unplugged from power receptacle when installing or performing any maintenance 3 This cooler will run on 120 volt A C 60 Hz cycle current only 4 Motor and pump are grounded and have an automatic thermal overload switch which will shut motor off when it overheats The motor will restart automatically when it cools down 5 Pump receptacle is for grounded evaporative cooler pump only Do not plug anything else into receptacle WARNING To reduce the risk of fire or electric shock do not use this fan with any solid state fan speed control device www championcooler com 9 09 Operation Manual Control Units Pump setting The rotary switch has 6 settings The Pump setting will operate the pump without the blower For best results turn the switch to Pump for a few minutes to wet the pads before operating the fan High and low cool settings The High Cool and Low Cool set tings operate both the pump and the blower Turn the unit to Low Cool when possible This lower speed allows the air to stay long

Download Pdf Manuals

image

Related Search

Related Contents

Les journées Portes Ouvertes dans le cadre du Printemps de l  Keysight U1251B y U1252B Multímetro digital portátil  Service Manual – Iced Tea & Combo Brewer  Thule Kit 138 User's Manual  Lightolier MFE-Biax User's Manual  to the current Performance Denali manual  Samsung ES9 Instrukcja obsługi  価格表pdf形式272KB  MailFax Administrative Website User Manual (For Ford  FORA G20 BLOOD GLUCOSE MONITORING SYSTEM English  