Home
Epson Structural Round Ceiling Plate Installation Guide
Contents
1. holes in the side of the threaded fitting Insert and tighten one M5 x 10 mm phillips screw C into hole to FLUSH MOUNT lock flush mount tube to threaded fitting ecm 2 Screw flush mount from top of ceiling plate A as NOTE For security option use M5 socket pin screw D in place of screw C Tighten using 4 mm allen wrench E 4of7 ISSUED 02 13 08 SHEET 054 9126 2 07 10 08 Visit the Peerless Web Site at www peerlessmounts com For Technical Support Contact Peerless Mounts at 1 800 729 0307 or 708 865 8870 Installation to Wood Joist Finished Ceilings Exposed Wood Joists or Wood Beam Ceilings A WARNING e Installer must verify that the supporting surface will safely support the combined load of the equipment and all attached hardware and components Tighten wood screws so that ceiling plate is firmly attached but do not overtighten Overtightening can damage the screws greatly reducing their holding power Never tighten in excess of 80 in Ib 9 N M Make sure that mounting screws are anchored into the center of the wood joist or wood beam The use of an edge to edge stud finder is highly recommended Hardware provided is for attachment of mount through standard thickness drywall or plaster into wood joist or wood beam ceilings Installers are responsible to provide hardware for other types of mounting situations Drill two 5 32 4 mm dia holes to a minimum depth of 2 5 64 mm Attach ceiling plat
2. shown below Be sure concrete anchors do not pull away from concrete when tightening screws If plaster drywall is thicker than 5 8 custom fasteners must be supplied by installer Not evaluated by UL A WARNING Tighten screws so that ceiling plate is firmly attached but do not overtighten Overtightening can damage screws greatly reducing their holding power Place ceiling plate A over anchors G and secure with screws B Tighten all fasteners e Never tighten in excess of 80 in lb 9 N M em INCORRECT E ioe concrete i il pr he 4 t G gt a Aoa h i 2 Sfp ge p Pa CORREG E Tg D gt O Sie Visit the Peerless Web Site at www peerlessmounts com For Technical Support Contact Peerless Mounts at 1 800 729 0307 or 708 865 8870 LIMITED FIVE YEAR WARRANTY Peerless Industries Inc establishes a warranty period of five years for products manufactured or supplied by Peerless This period commences from the date of sale of the product to the original consumer but will in no case last for more than six years after the date of the product s manufacture During the warranty period such products will be free from defects in material and workmanship provided they are installed and used in compliance with the instructions established by Peerless Industries Inc Subject to applica
3. Installation and Assembly Structural Round Ceiling Plate Model E LPM BP03 This product is UL Listed It must be H US installed by a qualified professional installer Maximum UL Load Capacity 150 Ib 68 kg Manufactured by Peerless Industries Inc 3215 W North Ave Melrose Park IL 60160 800 865 2112 or 708 865 8870 Fax 708 865 2941 www peerlessmounts com ISSUED 02 13 08 SHEET 054 9126 2 07 10 08 NOTE Read entire instruction sheet before you start installation and assembly A WARNING Do not begin to install your product until you have read and understood the instructions and warnings contained in this Installation Sheet If you have any questions regarding any of the instructions or warnings call Peerless customer care at 1 800 729 0307 This product should only be installed by someone of good mechanical aptitude has experience with basic building construction and fully understands these instructions Make sure that the supporting surface will safely support the combined load of the equipment and all attached hard ware and components Never exceed the Maximum UL Load Capacity If mounting to wood joists or wood beam ceilings make sure that mounting screws are anchored into the center of the joists or beams Use of an edge to edge stud finder is highly recommended Always use an assistant or mechanical lifting equipment to safely lift and position equipment Tighten screws firm
4. ble legal requirements during the warranty period Peerless will repair or replace or refund the purchase price of any such product which fails to conform with this warranty Any other warranties prescribed by the law which may apply with respect to such products also are limited in duration to the warranty period specified in this Limited Five Year Warranty This warranty does not cover damage caused by a service or repairs by the customer or a person who is not authorized for such service or repairs by Peerless Industries Inc b the failure to utilize proper packing when returning the product c incorrect installation or the failure to follow Peerless instructions or warnings when installing using or storing the product or d misuse or accident in transit or otherwise including in cases of third party actions and force majeure In no event shall Peerless be liable for incidental or consequential damages or damages arising from the theft of any product whether or not secured by a security device which may be included with the product This Limited Five Year Warranty is in lieu of all other warranties expressed or implied and is the sole remedy with respect to product defects No retailer dealer distributor installer or other person is authorized to modify or extend this warranty or impose any obligation on Peerless in connection with the sale of any product manufactured or supplied by Peerless This warranty gives specific legal
5. e A to the joist center using two 14 x 2 5 wood screws B as shown Tighten wood screws B using 3 8 10 mm socket wrench so ceiling plate A is firmly attached 5 of 7 ISSUED 02 13 08 SHEET 054 9126 2 07 10 08 Visit the Peerless Web Site at www peerlessmounts com For Technical Support Contact Peerless Mounts at 1 800 729 0307 or 708 865 8870 Installation to Solid Concrete A WARNING Concrete must be 2000 psi density minimum Lighter density concrete may not hold concrete anchor e Make sure that the supporting surface will safely support the combined load of the equipment and all attached hard ware and components Use ceiling plate A as a template to mark holes Drill four 1 4 6 mm dia holes to a minimum depth i CONCRETE of 2 5 64 mm Insert four anchors G in holes CEILING flush with ceiling as shown in figure 3 1 Place ceiling plate A over anchors G and secure with 14 x 2 5 6 mm x 65 mm wood screws B Tighten wood screws B using 3 8 10 mm socket wrench to firmly attach ceiling plate A See figures 3 2 and 3 3 A WARNING Always attach concrete anchors directly to load bearing concrete Never attach concrete anchors to concrete covered with plaster drywall or other finishing material If mounting to concrete surfaces covered with a finishing surface is unavoidable the finishing surface must be counterbored as
6. ion Qty Part A round ceiling plate 055 2798 B 14 x 2 5 wood screw 5S 1 015 C04 C M5x 8x 10 mm phillips screw 520 2005 D M5 x 8 x 10 mm socket pin screw 520 2031 E 4mm allen wrench 560 9646 F rubber grommet 530 9401 G concrete anchor 590 0097 NON SS 3 of 7 ISSUED 02 13 08 SHEET 054 9126 2 07 10 08 Visit the Peerless Web Site at www peerlessmounts com For Technical Support Contact Peerless Mounts at 1 800 729 0307 or 708 865 8870 amp Place grommet F into hole of ceiling plate A NOTE Make sure grommet overlaps retaining A a collar Grommet may require some force to fit in hole and will appear slightly deformed RETAINING COLLAR e For safety extension column must be locked to threaded fitting with screw Extension Column Applications Insert end of extension column into threaded fitting of ceiling plate A Tighten four or five complete turns Align slot in extension column with one of the small holes in the side of the threaded fitting Insert and tighten one M5 x 10 mm phillips screw C into hole to lock extension column to threaded fitting THREADED FITTING NOTE For security option use M5 socket pin screw D in place of screw C Tighten using 4 mm allen wrench E ULLISTED ELPMBC01 AND EXT ORADJ SEIRIES SOLD SEPARATELY Flush Mounting Applications oS shown in fig 2 Tighten four or five complete turns Align slot in flush mount tube with one of the small
7. ly but do not overtighten Overtightening can damage the items greatly reducing their holding power This product is intended for indoor use only Use of this product outdoors could lead to product failure and personal injury When installing or adjusting the ceiling mount do not use adhesives lubricants or oils to prevent the screws from loosening If you use adhesives lubricants or oils to prevent the screws from loosening the casing may crack and the projector may fall causing serious injury and damage to the projector Tools Needed for Assembly stud finder edge to edge stud finder is recommended e phillips screwdriver e 3 8 10 mm socket wrench e drill e 1 4 bit for concrete surface e 5 32 bit for wood studs Table of Contents ES oe K 2 ee A A EE eee E 3 Extension Column and Flush Mounting Applications ccceeccceceeceeeeeceeeeeeeeeeeeeeaaeeeeeaeeeseeeeeeeecaaaeeseaaeessaaaeeseaeeeeseneeeeenaaees 4 Installation to Wood Joist Finished Ceilings Exposed Wood Joists or Wood Beam Ceilings cccccceceeseeeetceeeeeeseeaeees 5 installation to Solid Concrete ee 6 Warranty IMTOrmatin eseese arinnar ennie Ea e EEEN TE EE ENEE AAE EEEE EEEE TAE E EE TEREE Raa E 7 Visit the Peerless Web Site at www peerlessmounts com For Technical Support Contact Peerless Mounts at 1 800 729 0307 or 708 865 8870 Before you begin make sure all parts shown are included with your product Parts List Descript
8. rights and you may also have other rights provided by the national legislation of the country in which you purchased such product peerless www peerlessmounts com 2007 Peerless Industries Inc ISSUED 03 17 06 LIT 0190E 7of7 ISSUED 02 13 08 SHEET 054 9126 2 07 10 08 Visit the Peerless Web Site at www peerlessmounts com For Technical Support Contact Peerless Mounts at 1 800 729 0307 or 708 865 8870 2008 Peerless Industries Inc All rights reserved Allother brand and product names are trademarks or registered trademarks of their respective owners