Home

Enviro ACCENT 25BV User's Manual

image

Contents

1. C Minimum firebox size W 27 x H 22 x D 17 W 68 5 x H 55 8 x D 43 1 cm Maintain sufficient clearances for operation service and maintenance 3 VENTING WARNING THIS APPLIANCE HAS BEEN DESIGNED TO OPERATE BY DRAWING COMBUSTION AIR AND DILUTION AIR FROM THE ROOM IT IS ALSO DESIGNED TO DRAW ROOM AIR FOR PROPER HEAT CIRCULATION FROM THE SIDES OF THE UNIT BLOCKING OR MODIFYING THE LOUVERS IN ANY WAY CAN CREATE HAZARDOUS SITUATIONS EITHER THROUGH POOR VENTING OR BY OVERHEATING IT IS IMPORTANT THAT THIS UNIT HAS SUFFICIENT AIR CIRCULATION FOR PROPER VENTING AND COMBUSTION PROVISIONS MUST BE MADE FOR THE SUPPLY OF ADEQUATE COMBUSTION AND VENTILATION AIR THESE OPENINGS MUST NOT BE BLOCKED THE APPLIANCE MUST NOT BE CONNECTED TO A CHIMNEY FLUE SERVICING A SEPARATE SOLID FUEL BURNING APPLIANCE AUTOMATIC FLUE GAS SPILL SWITCH NOTE THIS HEATER MUST BE PROPERLY CONNECTED TO A VENTING SYSTEM THIS HEATER IS EQUIPPED WITH A VENT SAFETY SHUTOFF SYSTEM DESIGNED TO PROTECT AGAINST IMPROPER VENTING OF COMBUSTION PRODUCTS THIS SAFETY SWITCH IS LOCATED ON THE REAR OF THE APPLIANCE CLOSE TO THE DRAFT HOOD RELIEF OPENING IF THE SWITCH TRIPS MORE THAN ONCE THE VENTING SHOULD BE INSPECTED BY A QUALIFIED SERVICE TECHNICIAN FOR POSSIBLE BLOCKAGE OR SEVERE DOWN DRAFT CONDITIONS The draft hood must be in the same pressure zone as the air inlet To inspect draft from the front
2. When finished release pressure remove hose amp tighten set screw Pilot Adjustment Screw Hi Low Knob 8 Pipe Manifold Pressure Tap Inlet Pr ssure Tap ORIFICE SIZES PRESSURES AND BTU S All models are equipped with a variable output gas control NATURAL PROPANE MAIN BURNER ORIFICE 42 DMS 53 DMS Manifold Press 3 8 wc 0 95 kpa 11 0 wc 2 74 kpa Min Manifold Press 1 1 wc 0 27 kpa 2 7 wc 0 67 kpa Max Supply Press 7 0 wc 1 74 kpa 12 0 wc 2 98 kpa Min Supply Press 5 0 wc 1 25 kpa 11 5 wc 2 86 kpa Max BTUH Input 25 000 btu h 7 32 Kw 25 000 btu h 7 32 Kw Min BTUH Input 12 500 btu h 3 66 Kw 12 500 btu h 3 66 Kw Output Fan on 18 875 btu h 5 53kw Fan on 19 250 btu h 5 64kw Fan off 18 000 btu h 5 27 kw Fan off 18375 btu h 5 38kw NEVER USE AN OPEN FLAME FOR LEAK TESTING 7 INSTALLATION OF LOGS EMBERS and BRICK PANELS INSTALLING THE GLOWING EMBERS and LOGSET A bag of ceramic fiber embers is provided for use on the burner PAN CAUTION Use only the type of ember material supplied with this appliance Due to the irregular size of the ember material there may be more than required Use only a single layer Do not pile embers The use of other foreign materials on the burners may create dangerous conditions If over time through cleaning and servicing these embers require replacement contact your nearest ENVIROGAS dealer for replacement embers 1 Carefully remove log from unit Check to ensur
3. control knob to 3 Turn the gas control knob OFF and call you clockwise to the off position IN service technician 4 Open door Wait five 5 minutes to clear out any or gas supplier gas Close door If you smell gas including near the floor STOP Follow B in the above safety information If you don t smell gas go to next step 5 Find the pilot located to the right between the front and rear burner 6 Turn gas control knob counter clockwise to PILOT 7 Push the gas control knob in fully and hold Immediately light the pilot by pushing the piezo spark igniter Keep knob depressed for about 30 seconds after pilot is lit Release knob If pilot goes out repeat steps 4 through 6 WARNING The gas valve has a lockout device which HI LO knob Control knob will not allow the pilot burner to be re lit until the thermocouple has cooled If the knob does not pop up when released stop and 8 Turn gas control knob counter clockwise to the immediately call your service technician or gas ON position supplier Flip burner switch to ON then turn HI LO knob to the desired setting NOTE Check to be sure the pilot flame engulfs the thermocouple and that the burners light 9 Turn on all electrical power to the unit completely TO TURN OFF GAS TO APPLIANCE 1 Turn the gas control knob Ls clockwise to OFF DO NOT FORCE 2 Turn off all electrical power to the appliance if service is to be
4. e In Canada the unit must be derated by 10 for installation at elevations between 2 000 810 m and 4 500 feet 1370 m NATURAL GAS PROPANE GAS INPUT 20814 6 09 Kw 44 DMS INPUT 22257 6 52 Kw 54 DMS e Inthe USA these appliance are certified for elevations up to 2 000 feet 810 m For elevations above 2 000 feet 810 m input should be reduced 4 for each 1 000 feet 405 m above sea level ACCENT 25 e Has been certified for use with either natural or propane gases see rating label e Is not for use with solid fuels e ls approved for bedroom or bedsitting room A thermostat must be installed in Canada e Must be installed in accordance with local codes If none exist use current installation code CAN CGA B149 in Canada or ANSI Z223 1 NFPA 54 in the USA e Must be properly connected to a venting system WARNING For installation only in a solid fuel burning fireplace with a working flue and constructed of non combustible material using a chimney liner kit CODES AND APPROVALS CONTINUED RE CONVERSION OF ZERO CLEARANCE FACTORY BUILT FIREPLACES The following instructions cover Sherwood Industries Ltd policy for Gas Fired Appliances inserts to be retofitted into existing factory built fireplaces with replacement parts removed GENERAL REQUIREMENTS Background A gas fired insert is approved for use in an existing masonry or a listed factory built fireplace without any alterations If the factory or masonry fireplace
5. SHERWOOD INDUSTRIES IS AN ENVIRONMENTALLY RESPONSIBLE COMPANY THIS MANUAL IS PRINTED ON RECYCLED PAPER Warnock Hersey A C C E N T 2 5 BV wa By SHERWOOD INDUSTRIES LTD C iam US OWNERS MANUAL WHAT TO DO IF YOU SMELL GAS WARNING e Open windows Extinguish any open flame If the information in this e Do not try to light any appliance manual is not followed exactly a fire or explosion may result causing property damage personal injury or loss of life Installation and service must be performed by a qualified installer service agency or the gas supplier e Do not touch any electrical switch do not use any phone in your building e Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions e If you cannot reach your gas supplier call the fire department Do not store or use gasoline or other Flammable vapors and liquids in the vicinity of this or any other appliance PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE SAFETY PRECAUTIONS FOR SAFE INSTALLATION AND OPERATION OF YOUR ENVIROGAS HEATER PLEASE CAREFULLY READ THE FOLLOWING INFORMATION e AI ENVIROGAS gas fired appliances must be installed in accordance with these instructions Carefully read all the instructions in this manual first Consult the building authority havin
6. an efficient flame in the fireplace STEP 12 MAKE SURE that the sticker provided by S I T is installed to signify that this valve has been converted to a different type of fuel Also make sure that the rating plate has a conversion label to show that this unit has been converted to a different fuel type A VISUAL CHECK OF THE REGULATOR KNOB IS NECESSARY TO DETERMINE WHETHER OR NOT THE REGULATOR IS THE CORRECT PART A 50 TURN DOWN REGULATOR WILL HAVE ONLY ONE CORNER ON THE KNOB CONVERSION KIT PARTS LIST 1 50 turn down HI LOW Regulator w 3 T 20 Torx NATURAL GAS PROPANE screws Pilot Orifice 62 mm 35 mm 1 pilot injector Burner Orifice 42 DMS 53 DMS 1 Main orifices 1 Pilot assembly mounting gasket Venturi Settings 1 16 open 3 8 open 13 11 TROUBLE SHOOTING Problem Possible Cause Solution Spark will not arc to the pilot after Defective piezo ignitor Check connections to ignitor repeated pressing of spark ignitor If ignitor connections are good but there is no spark replace ignitor Broken spark electrode Check for broken ceramic insulation replace electrode if broken Miss aligned spark electrode If spark is not arcing from the electrode to pilot adjust by loosening screws on pilot base Adjust away from burner and re tighten Pilot will not remain lit Problem with thermocouple circuit Check for proper connection of thermocouple to rear of valve If loose tighten lightly Check pilot for full flame impin
7. flexible liner to accommodate the height of the chimney Make sure that all chimney clean outs are tightly fitting and will not permit air to leak into the chimney The chimney must be clean in good working order and constructed out of non combustible materials Any flue damper must be removed or blocked permanently in the open position Remove the vent collar plate from the top of the insert and connect it securely with sheet metal screws and or hose clamps Check for any tears in the liner at this point See also Assembly and Installation Instructions section 3 IMPORTANT The screws that hold the vent collar plate in it s approved position must be installed PREPARATION FOR INSTALLATION e Remove the packaging from the appliance and surround panels check to make sure there is no damage Carefully check the glass door Do not use the unit if it is damaged In the event damage is found please report it to both the courier and your dealer as soon as possible e Carefully clean the fireplace and flue before installing the stove Failure to do so may result in fumes or dirt being blown into the room and may cause a fire leading to death or serious injury 4 ASSEMBLY AND INSTALLATION INSTRUCTIONS ASSEMBLING AND INSTALLING YOUR ENVIROGAS ACCENT 25 1 Remove the unit from it s box DRAFT HOOD 2 Open the door by first removing the cover with the nameplate ADJUSTMEN attached open valve door and pull nameplate cover T si
8. of the unit Remove top louvers by pulling up and out Locate the 3 8 tube between the heat exchanger and top check for a draft using smoke A vacuum or suction into the tube will indicate proper drafting This model can be vented with 4 aluminum or stainless steel flex vent and or certified Type B Gas Vent The flue collar of the appliance will fit inside of a standard 4 vent and may be fastened directly to the vent Check periodically that the vent is unrestricted and an adequate draft is present when the unit is in operation 3 VENTING FIREPLACE INSERTS WARNING Operation of this heater when not connected to a properly installed and maintained venting system can result in carbon monoxide CO poisoning and possible death The Envirogas ACCENT 25 may be installed and vented into any solid fuel fireplace that has been installed in accordance with the National Provincial State and local building codes and has been constructed of non combustible materials An approved full length chimney liner and rain cap must be used A throat connector or flashing must be installed to ensure a tight seal top performance safety and efficiency Carefully follow the manufacturers instructions which accompany the chimney liner kit Install sealed throat connector or flashing to prevent leakage of room air up through chimney p Measure the height of the chimney beforehand and purchase the appropriate kit Never attempt to over stretch a
9. performed 3 Flip burner switch to off 11 9 ROUTINE MAINTENANCE and SERVICE Periodically check to ensure that your system is clean Periodically check the pilot and burner Check to see that all the burner ports are clean and clear Check the pilot head for blockage Check to ensure the pilot flame is blue with yellow tips NOTE Wipe the gold louvers with a soft cloth before firing unit If left fingerprints can become etched in the gold OPENING THE DOOR Turn unit off and wait until the appliance has cooled down Open the lower louver panel Undo the two bolts at the bottom corners of the door Swing door out then lift up and out to remove Ensure the door is properly fastened after cleaning before attempting to re light the appliance CLEANING THE GLASS Do not clean glass when hot It will be necessary to clean the ceramic glass periodically During a cold start up condensation will sometimes form on the glass this is a normal condition with all gas fireplaces and stoves However this condensation can allow dust and lint to cling to the glass surface Initial paint curing of the appliance can leave behind a slight film on the glass This is a temporary problem It is therefore recommended that the glass be cleaned initially after about the first two weeks of use To clean the door use a mild glass cleaner and a soft cloth Abrasive cleaners will damage the glass and gold surfaces TO REPLACE DOOR GLASS Th
10. the 7 BURNER grounding prong from this plug 120 F 60 C TEMP SENSOR CAUTION Label all wires prior to disconnection when servicing controls Wiring errors can cause improper and dangerous PLACE THERMOSTAT operation Verify proper WIRES HERE operation after servicing Turn the unit off open the door and remove the log set Remove brick panel s see Removing and Installing Brick Panels Remove the burner tray assembly by removing the two 2 screws on either side of the tray Pull tray up at the back and lift out Disconnect the gas line to the nipple Remove the three 3 screws holding the burner control tray to the back firewall Lift tray up on left side and pull out Pull blower towards you Disconnect wires from the blower and remove To re install perform the preceding steps in reverse INSTALLING REMOTE THERMOSTAT OR WALL SWITCH RECOMMENDED WIRE SIZE for thermostat installation 18 gauge 2 wire solid core Low Voltage wire Bell wire Install the 18 Gauge wire supplied to the two terminals on the thermostat or remote wall switch Connect the other end of the wire to the gas valve using the two outside terminals on the front of the gas valve Use the terminals marked TP TH and TH RECOMMENDED MAXIMUM LEAD LENGTH TWO WIRE WHEN USING WALL THERMOSTAT WIRE SIZE MAXIMUM LENGTH 14 GAUGE 100 FEET 16 GAUGE 64 FEET 18 GAUGE 40 FEET 20 GAUGE 18 FEET 6 GAS LINE CON
11. the original owner in the original location Covered under the lifetime warranty are Cabinet Sides Tops Pedestals Surround Panels and Chassis and Heat Exchanger These steel components are covered against manufacturer s defects for 5 years and labor for the first year and for parts only thereafter A The following exclusions apply over firing due to incorrect setup or tampering damage caused by incorrect installation usage or abuse The unit must be properly installed by a qualified technician or installer and must meet all local and national gas and building code requirements We also cover against manufacture defects under our lifetime warranty The following components Gold Plating Log Set Burners and Glass A The following exclusions apply Gold plating Damage caused by scratching marring chemicals fingerprints abrasive cleaners or discoloration with age Glass use of harsh or abrasive cleaners striking the glass or surface contaminates Logset Damage caused by incorrect handling or misuse Burners damage caused by improper or continuous operation under incorrect conditions Sherwood Industries Ltd offers a 2 year warranty on all the Electrical Components and Gas Components against manufacturing defects Paint is covered against flaking This offer includes parts and labor for 1 year and for parts only thereafter The paint on the Metal Brick Liner may peel This is due to the extreme conditions applied to the paint and is n
12. NECTIONS and TESTING WARNING Only persons licensed to work with gas piping may make the necessary gas connections to this appliance GAS LINE CONNECTION e This stove is equipped with a 3 8 x 3 inch black iron nipple located on the right side of the unit terminating in a 3 8 male NPT fitting Consult your local authorities codes or the CAN CGA B 149 1 or 2 installation code in Canada or in the USA gas installations follow either local codes or the current edition of the National Fuel Gas Code ANSI 2223 1 e The efficiency rating of this appliance is a product thermal efficiency rating determined under continuous operating conditions and was determined independently of any installed system The appliance and its shutoff valves must be disconnected from the gas supply piping system during any pressure testing where the pressure exceeds 1 2 PSIG 3 45 kpa or damage will occur to the valve The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1 2 psig 3 5 kPa Always check for gas leaks with a soap and water solution after completing the required pressure test TO TEST VALVE PRESSURES The pressure taps are located on the left side of the valve Turn set screw 1 turn counter clockwise to loosen Place 5 16 8 mm I D hose over pressure tap system Check pressures using a manometer
13. a or the National Fuel Gas Code ANSI Z223 1 in the USA e To prevent injury do not allow anyone who is unfamiliar with the operation to use the stove e To prevent injury if the pilot or pilot and burners have gone out on their own open the glass door and wait 5 minutes to air out before attempting to re light stove e Always keep the area around these appliances clear of combustible material gasoline or other flammable vapors and liquids e These appliances should not be used as a drying rack for clothing or for hanging Christmas stockings or decorations e Due to the paint curing on the stove a faint odor and slight smoking will likely be noticed when the stove is first used Open a window until the slight smoking stops e Always connect this gas stove to a vent system and vent to the outside of the building envelope Never vent to another room or inside a building Make sure you use the vent pipe that is specified Make sure that the vent is properly sized and is of adequate height to provide the proper draft Inspect the venting system annually for blockage and any signs of deterioration WARNING Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or personal injury WARNING Do not operate with the glass front removed cracked or broken Replacement of the glass should be done by a licensed or qualified se
14. ase complete and mail the warranty registration card and have the installer fill in the installation data sheet in the back of the manual for warranty and future reference 14 INSTALLATION DATA SHEET The following information must be recorded by the installer for warranty purposes and future reference Envirogas Model ACCENT 25 BV Name of Owner Name of Dealer Address Address Model Name of Installer Serial Number Address Date of Purchase Date of Installation _____ Natural Gas Nat ___ Propane LPG Inlet Gas Supply Pressure in w c If the orifices were changed by the installer e Front Burner Orifice Back Burner Orifice e Pilot Orifice Installer s Signature WEB SITE ADDRESS www Envirofire biz 8 28 2002 MANUFACTURED BY SHERWOOD INDUSTRIES 6782 OLDFIELD RD SAANICHTON B C CANADA V8M 2A3 19
15. ator STEP 1 Carefully inspect all parts supplied with this conversion kit STEP 2 Shut the gas off and disconnect the main gas line from the unit STEP 3 Open the door by undoing the two screws on the bottom of the door pull door towards you then lift up and out Remove the logs and the burner tray from the unit this will expose the main burner orifice and the pilot assembly STEP 4 Change the regulator on the front of the gas valve Follow the instructions provided by S I T STEP 5 To change the pilot orifice First pull the pilot head of the pilot assembly using a 5 16 allen key remove the pilot injector for assembly Install the new pilot injector for the fuel being used BE CAREFUL WHEN TIGHTENING THE PILOT FITTING YOU COULD BREAK THE CERAMIC IGNITER ELECTRODE STEP 6 Re install the pilot assembly in the reverse order of STEP 5 STEP 7 Remove the main burner orifice using a 7 deep socket STEP 8 Install the new orifice supplied Be sure to put a bead of pipe thread sealant or approved Teflon tape on the orifice before installing the orifice into the burner assembly STEP 9 Re install the burner tray in unit log set and door STEP 10 Reconnect the gas line to the unit Do a leak check using a soap and water solution or an approved manner on the gas supply line and the pilot tubing STEP 11 Re light the appliance to insure proper operation and proper flame appearance Be sure to adjust the venturi setting to achieve
16. ay the panel face down on a soft flat surface and place the brass trim on the surround panel using the corner brackets supplied and spring clips to hold trim to the surround panel 11 Connect the surround panel wire harness terminal to the stove wire harness terminal on the right side panel 12 Place the assembled surround panel around the stove align the tabs with the slots in the front of the unit Push back then down to engage the surround slots on the mounting slots Make sure the top surround panel sits flat on the stove If not use the leveling legs on the unit 5 ELECTRICAL REQUIREMENTS The ACCENT 25 will operate without electrical power This model has a Millivolt gas control which uses the pilot flame to generate enough electricity to operate the main burners The appliance when equipped with blower must be electrically connected and grounded in accordance with local codes or in the absence of local codes with the current CSA C22 1 CANADIAN ELECTRICAL CODE Part 1 SAFETY STANDARDS FOR ELECTRICAL INSTALLATIONS OR THE NATIONAL ELECTRICAL CODE ANSI NFPA 70 in the U S REMOVING INSTALLING THE BLOWER 1 300F 149C MANUAL RESET SPILL SWITCH WARNING Electrical ORANGE grounding instructions This appliance is equipped with a FAN three prong grounding plug for UE CONTROLLER your protection against shock hazard and should be plugged directly into a properly grounded three prong outlet DO NOT cut or remove
17. de tab to release catch undo the two bolts at the bottom of the door Lift the door up and out to remove CAUTION GLASS MAY SEPARATE FROM DOOR 3 Remove log and ember set and all wrapping material from the stove Remove wrapping material from log and embers and check for any damage If damage is observed do not use unit and contact your local dealer 4 Measure the distance from the front of the fireplace facing to the front of the flex liner in the chimney 5 Loosen the two adjustment screws and adjust the sliding exhaust channel to the dimensions measured in STEP 1 Re tighten screws oo 6 Remove the front exhaust locating screw Slide the exhaust channel backwards from the unit Properly secure the exhaust channel to the 4 flexible vent pipe liner previously installed in the chimney using 3 three sheet metal screws Be careful not to over stretch the liner LEVELING LEGS 7 Place the unit part way into the fireplace Connect the fireplace insert s rigid gas line to the household gas supply using locally approved methods Place the P electric cable so it can be connected to the power supply A Adjust the leveling legs 8 Slide the insert into the fireplace ensuring that the exhaust channel is located under the slide rails on the top i ba Os of the fireplace insert N ER u N f f en lt lt a 9 Re install the locating screw and tighten 8 yee de gt zen 10 To assemble the surround panel l
18. e glass in this appliance is 5 MM ceramic If the glass is damaged or broken a factory replacement must be fitted To Replace e Open door remove the glass carefully e Install the new piece of glass with the large bulb in the gasket tape against the unit Place the joint in the tape in a bottom corner Close door Glass must be purchased from an Envirogas dealer No substitute materials are allowed CLEANING THE INSIDE OF THE FIREBOX Remove the log carefully from the firebox Gently remove the embers and place on a piece of paper towel Until ready to replace Vacuum the bottom of the firebox thoroughly Carefully clean off any dust on the logs and brick panels and remove any lint from the main burner and pilot burner 12 After carefully replacing the log and embers in their correct positions and the door has been resealed re light the pilot following the instructions on the attached label CLEARANCES MUST BE SUFFICIENT TO ALLOW ACCESS FOR MAINTENANCE AND SERVICE Depending upon the amount of use cleaning should be required no more than two or three times per season REMOVING BURNER CONTROLS 1 Shut of gas supply to appliance 2 Remove surround panels by pulling up then out disconnect gas line from the valve Disconnect harness at connector on side of unit 3 Open the door and remove the log Remove the burner tray assembly by removing the two screws on either side of the tray Pull tray up at the back lift tra
19. e there is no damage It is very important to install this log in its proper position to insure safe optimum operating conditions Place the log set into the firebox with the burnt area forward Locate the log by seating it down onto the burner tray supports already installed Gently remove the ember material from the plastic bag Place a single line of embers on burner as shown beside Carefully avoid any clumping or large build ups Do not pack down leave embers loose Upon the first light up watch for ignition to all burner ports Ifa long delay is noted First wait for the appliance to cool down e Open the front door of the appliance e Check to carefully reposition the embers making sure that burner ports are not plugged solid or blocked 10 REMOVING AND INSTALLING THE BRICK PANELS Open the door Remove the log set Optional ceramic panels Remove burners Gently pull right brick side panel inwards from the bottom back Pull towards the back then out freeing it from the front retainer Caution pilot may damage panel Remove the left side panel the same way Remove the back panel from ledge To install place back panel on ledge Insert front edge of brick panel into the retainer and very gently move panel forward and out until flush against firebox side Repeat for other side CAUTION NEVER OPERATE THIS APPLIANCE WITH THE DOOR REMOVED Place ember material in the shaded area only Do not pack ember mate
20. g jurisdiction to determine the need for a permit prior to commencing the installation e NOTE Failure to follow these instructions could cause a malfunction of the fireplace which could result in death serious bodily injury and or property damage e Failure to follow these instructions may also void your fire insurance and or warranty GENERAL e Installation and repair should be done by a qualified service person The appliance should be inspected before use and at least annually by a qualified service person More frequent cleaning may be required due to excessive lint from carpeting bedding material etc It is imperative that control compartments burners and circulating air passageways of the appliance be kept clean e Due to high temperatures the appliance should be located out of high traffic areas and away from furniture and draperies Children and adults should be alerted to hazards of high surface temperatures and should stay away to avoid burns or clothing ignition e Young children should be carefully supervised when they are in the same room as the appliance e Clothing or other flammable material should not be placed on or near the appliance FOR YOUR SAFETY e Installation and service must be performed by a qualified installer service agency or the gas supplier e This installation must conform with local codes or in the absence of local codes with the current CAN CGA B149 installation code in Canad
21. gement around thermocouple If the pilot is to small Check gas pressure adjust pilot rate screw check pilot head for blockage Check thermocouple voltage at rear of valve must be greater than 5 mV If low replace thermocouple Air in gas line Pilot flame dies while Bleed line knob is depressed Check gas line pressure Contact dealer Burners will not remain lit Problem with thermopile circuit Check gasline pressure Check for flame impingement on thermopile if low see Pilot will not stay lit Check thermopile for a Minimum of 300 mV when burner switched on Check wiring to thermostat for breaks BV only Check for spillage at draft hood that may trip spill switch Flame lifting Leak in vent pipe check for leaks in vent connections Improper vent configuration check vent configuration with manual Terminal may be recirculating flue check to see if terminal is on correctly gases May need to install high wind termination cap contact dealer BV only insufficient air for Air tight house supply make up air to the unit combustion A Vacuum in room due to other air moving device Glass fogs up Normal conditions after the appliance warms up glass will clear Due to additives in gas glass may get hazy during normal use Clean when needed Normal during start flame will yellow as the appliance heats up Flames are burning dirty or Sooting Flame impingement check log position inc
22. is altered its warranty is void Recent practice in the field is to remove parts that do not require cutting bending or breaking from the factory built fireplace in order to allow the insert to fit Sherwood Industries Ltd Policy Intertek has approved listed factory built fireplaces as a certified zero clearance kit provided that the following conditions have been met The removal of any part will not weaken the stuctural integrity of the factory built fireplace The factory built fireplace is in good condition There is no alterations in the form of cutting bending or breaking any parts Firebricks may be removed A permanent label must be supplied with the insertwith the instructions to affix it to the firebox of the factory built fireplace It will have the wording to the effect IRUN WARNING THIS FIRPLACE MUST ONLY BE OPERATED WITH A GAS INSERT REMOVAL OF THE INSERT AND THE USE OF SOLID FUEL IS PROHIBITED AND MAY CAUSE A FIRE HAZARD REPLACEMENT PARTS INCLUDE Fire bricks smoke sheild flue damper glass doors and firescreens 2 DIMENSIONS AND CLEARANCES TO COMBUSTIBLES A DISTANCE TO COMBUSTIBLES Mantel pillar to surround panel 2 5 08 cm Floor to 8 wide mantel 40 101 cm Minimum non combustible surface in front of unit 8 20 8 cm OTHER DIMENSIONS A Minimum Depth of unit into fireplace 16 41 cm B Depth of unit out of fireplace 1 2 54 cm DH I l
23. o way covered under warranty Your dealer shall make all claims under this warranty in writing A TO A MAXIMUM OF SEVEN YEARS WHEN FILING A WARRANTY CLAIM PLEASE COMPLETE THE FOLLOWING INFORMATION ON AN OFFICIAL WARRANTY CLAIM FORM To the Dealer e Name address and telephone number of purchaser and date of purchase e Date of installation Name of installer and dealer Serial number of the appliance Nature of complaint defects or malfunction description and part of any parts replaced To the Distributor eSign and verify that work and information are correct This warranty covers defects in materials and workmanship only if the product has been installed according to the manual s instructions If the product is damaged or broken as a result of misuse or mishandling the warranty does not apply The warranty does not cover removal and re installation costs Sherwood Industries Ltd reserves the right to repair or to replace the defective product The shipping costs are to be paid by the consumer All warranties by the manufacture are set forth herein and no claim shall be made against the manufacturer on any oral warranty or representation Sherwood Industries Ltd and its employees or representatives will not assume any damages either directly or indirectly caused by improper usage operation installation servicing or maintenance of this appliance Sherwood Industries Ltd reserves the right to make changes without notice Ple
24. op and Bottom LP to NG Conversion Kit NG to LP Conversion Kit 15 pe 120 F 49 C FAN DRAFT HOOD cA SLIDER er FULLY Ne ASSEMBLED N LL EC 001 PILOT EC 015 NG EC 016 LP BRICK CLIPS THERMOPILE AND BACK EC 012 e LEDGE THERMOCOUPLE LINERS PAN BURNER Re EG25 074 POST APR 2000 ELECTRODE EC 011 BLACK IRON NIPPLE N EG25 062 LEVELING LEGS X2 LOUVER SET TOP amp BOTTOM EG25 115 PIEZO RATING IGNITER vee Bean Oo X K EG25 092 CONVECTION ZA re A BURNER ORIFICE CONVECTION BLOWER AO BLOWER EC 069 MOUNT S nn MAIN vA pa EC 022 sit NOVA 820 GAS VALVE we Lee EC 006 NG ea EC 007 LP MOUNT ACCENT 25 INSERT ung EXPLODED VIEW PAGE 2 of 2 JUNE 2002 GOLD 50 009 NICKEL 50 010 ON OFF THERMOSTAT SWITCH BURNER SWITCH EC 026 NOT SHOWN ACCENT 25 OVERSIZE SURROUND WITH PAINTED TRIM 50 108 BRASS TRIM 50 013 NICKEL TRIM 50 014 E ACCENT 25 EXPLODED VIEW SURROUND PANELS PAGE 1of 2 JUNE 2002 BRASS TRIM CORNER BRACKETS EC053 ACCENT 25 REGULAR SURROUND WITH TRIM PAINTED TRIM 50 107 BRASS TRIM 50 011 NICKEL TRIM 50 012 FAN CONTROLLER EC 039 FPI WIRING HARNESS PART A EC 034 NOT SHOWN 13 WARRANTY Sherwood Industries Ltd offers a Lifetime Warranty on this gas product The lifetime warranty covers the appliance for a period of seven years from the date of installation This warranty applies only to
25. rease primary air by opening venturi shutters see also Burners will not stay lit 14 PART EG25 001 EG25 002 EG25 003 EG25 004 EG25 008 EG25 014 EG25 015 EG25 018 EG25 026 EG25 030 EG25 031 EG25 032 EG25 035 EG25 036 EG25 040 EG25 041 EG25 042 EG25 043 EG25 044 EG25 052 EG25 053 EG25 062 EG25 065 EG25 070 EG25 072 EG25 073 EG25 074 EG25 075 EG25 088 EG25 089 EG25 090 EG25 092 EG25 110 EG25 114 EG25 115 EG25 200 EG25 202 12 PARTS AND ACCESSORIES Service Parts available from your local Envirogas Dealer DESCRIPTION Convection Blower Heyco Strain Relief Fan Controller with Knob Hi Temperature Electrical Cord Burner Switch 120 F Ceramic Auto Reset n o Temp Sensor big foot 300 F Temp Sensor n c Ceramic spill switch Wire Harness Valve Access Door Magnet Blank Orifice Thermocouple Ignitor electrode S I T Piezo Ignitor Ignitor Cable Thermopile SIT Nova 820 Valve NG 50 turndown SIT Nova 820 Valve LPG 50 turndown NOVA Pilot with Ignitor Electrode Natural Gas NOVA Pilot with Ignitor Electrode Liquid Propane Burner Controls Complete NG Burner Controls Complete LPG 3 x 3 8 Black Iron Pipe Nipple Burner Tray ENVIROGAS EG25 Nameplate Log Set amp Embers Embers Brick Panels Ceramic Brick Panel Metal Valve Gaskets Window channel tape Glass with Gasket Painted Door Regular Size Surround Panel Brass Surround Trim Louver set GOLD T
26. rial down 8 OPERATING INSTRUCTIONS FOR YOUR SAFETY READ BEFORE OPERATING WARNING IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE PERSONAL INJURY OR LOSS OF LIFE A This appliance is equipped with a pilot which must e lf you cannot reach your gas supplier call the be lit by hand by following these instructions exactly fire department B BEFORE LIGHTING smell all around the appliance C Use only your hand to push in or turn the gas area for gas and next to the floor because some control knob Never use tools If the knob will not gas is heavier than air and will settle on the floor push in or turn by hand do not try to repair it Call WHAT TO DO IF YOU SMELL GAS a qualified service technician Force or attempted e Do not try to light any appliance repair may result in a fire or explosion e Do not touch any electrical switch donot use D Do not use this appliance if any part has been any phone in your building under water Immediately call a qualified service e Immediately call your gas supplier from a technician to inspect the appliance and to replace neighbor s phone follow the gas supplier s any part of the control system and any gas control instructions which has been under water LIGHTING INSTRUCTIONS If the pilot will not 1 STOP Read the safety information above stay lit after several Turn off all electrical power to the appliance tries turn the gas
27. rvice person e Never use solid fuels such as wood paper cardboard coal or any other flammable liquids etc in this appliance e Do not use this heater if any part has been under water Immediately call a qualified service technician to inspect the heater and to replace any part of the control system and any gas control which has been under water e Do not abuse glass by striking or slamming door shut TABLE OF CONTENTS SECTION PAGE 1 Code Approvals 3 2 Dimensions and Clearances to Combustibles 5 3 Venting 6 4 Assembly and Installation Instructions 7 5 Electrical Requirements 8 6 Gas Line Connection and Testing 9 7 Installation of Log Sets and Embers and Brick Panels 10 8 Operating Instructions 11 9 Routine Maintenance and Service 12 10 Fuel Conversion 13 11 Trouble Shooting 14 12 Parts and Accessories 15 13 Warranty 16 14 Installation Data Sheet 17 1 CODES AND APPROVALS VENTED type is identified by the suffix BV This appliance draws in room air for combustion and vent dilution air e These appliances have been tested by Intertek Testing Services and found to comply with the established standards for GAS FIRED VENTED ROOM HEATER in CANADA and the USA as follows LISTED VENTED ROOM HEATER EG 25 BV Nat amp LPG TESTED TO ANSI Z21 88 1998 CSA 2 33 M98 VENTED GAS FIREPLACE HEATER CANADA and U S A CERTIFIED FOR INSTALLATION FROM 0 2000 FT 810 M FOR INSTALLATIONS ABOVE 2000 FEET 810 m
28. y out and towards the front 4 Remove the brick panel as per instructions Undo the three screws that hold the burner control tray onto the back firewall Lift control tray up on the left side and pull out Remove wire connector from firebox 5 Installation is the reverse Caution Bleed lines before lighting and light pilot with door open There is one venture and one air shutter on this appliance The venture has been set for installations at sea level Some adjustment could be required e To adjust for high altitude open the lower louvers locate the venturis between the burner and control trays Loosen the set screws with a long screwdriver and rotate the air shutter until an efficient flame is achieved 10 FUEL CONVERSION Warning This conversion kit shall be installed by a qualified service technician in accordance with the manufacturer s instructions and all applicable codes and requirements of the authority having jurisdiction If the information in these instructions is not followed exactly a fire explosion or CO poisoning may result The qualified service agency is responsible for the proper installation of this kit The installation is not proper or complete until the operation of the converted appliance is checked as specified in the owner s conversion kit Please read and follow these instructions Also please read the instruction guide lines provided by S I T on how to remove and install the HI LOW regul