Home

Emerson SS-100 User's Manual

image

Contents

1. 1 1 Working with the Network Administrator Like other computers on the network to which it is at tached the SS 100 is also a network node Because of this it is important to work with the network administrator Without the cooperation of the network administrator it will be difficult to make the SS 100 function properly 1 2 An IP address and subnet mask are denoted as a series of four decimal numbers separated with periods Each number has a value between O and 255 IP Address Specification The following are examples of valid IP addresses and subnet masks The actual numbers used as IP addresses must be determined by the network administrator IP Address 192 168 1 33 Subnet Mask 255 255 255 0 Empty IP Address 0 0 0 0 SS 100 Serial Server 1 3 Network Considerations Like any other node on the network the SS 100 must be assigned an IP address For this rea son the network administrator s input is required for the SS 100 installation Obtain the following information from the network administrator be fore configuring the SS 100 e SS 100 IP address required e Subnet mask required Primary DNS IP address may not be re quired Secondary DNS IP address may not be re quired Primary gateway IP address may not be required Secondary gateway IP address may not be required 1 4 Ethernet Network Wiring and Wire Types To connect the SS 100 to an existing Ethernet network use the
2. same standard Category 5 network cable used by the rest of the Ethernet network If the SS 100 is being wired as part of a brand new network installation consult your network administrator or IS technician for the proper wire type In either case you will need to crimp an RJ45 connector to the end of the network cable segment that will connect to the SS 100 2 SS 100 Wiring Requirements Required Equipment e 110VAC SVDC power transformer DB25 DB9 straight through connector STC e 535 1190 DB9 computer to REFLECS controller laptop cable UltraSite connection only DB25 null modem adapter HALComm connection only DB9 female female STC gender changer HAL Comm connection only Installation Guide e RJ45 connection to a TCP IP Network not provid Installing the SS 100 1 ed DB 25 DB 9 female female null modem cable not provided e Static IP Address Requirements for Computers Connecting to SS 100 BM PC running Windows 9x NT XP 2000 set up on an IP network e EzWebCon Installed download from www lan tronix com UltraSite version 3 30 or higher if using UltraSite 2 1 55 100 HALComm and UltraSite Wiring Layouts ECT LAN L1 IBM Compatible Modem Null Modem 55100 HALCOMM Wiring Layout with HALComm SS 100 Direct to HALComm Steps 1 Connect 25 pin female end of DB 25 null modem adapter to the 25 pin male port of the SS 100 2 Connect 25 pin female en
3. 026 1607 Rev 4 07 APR 2010 SS 100 Serial Server Installation and Programming Guide EMERSON SS 100 Serial Server Ver 3 6 9 s HY EMERSON 3240 Town Point Drive NW Suite 100 Kennesaw GA 30144 USA Phone 770 425 2724 Fax 770 425 9319 ALL RIGHTS RESERVED The information contained in this manual has been carefully checked and is believed to be accurate However Com puter Process Controls Inc assumes no responsibility for any inaccuracies that may be contained herein In no event will Computer Process Controls Inc be liable for any direct indirect special incidental or consequential damages resulting from any defect or omission in this manual even if advised of the possibility of such damages In the interest of continued product development Computer Process Controls Inc reserves the right to make improvements to this manual and the products described herein at any time without notice or obligation Table of Contents D EINSTFALLINGTHOE SS 100 lt lt aaa 1 1 1 WORKING WITH THE NETWORK ADMINISTRATOR ER share res 1 1 22 TPAADDRESS O PECIRICA ION oiii esse PLA in ibas pegao esten nak LII ak ig eo ase dera CUM Dae 1 3 NEFWORK TC ONSIDERATIONS area leet ET A at 1 I ETHERNET NETWORK WIRING AND WIRE DP ed 1 Z 39 100 WIRING REQUIREMENTS 2 u a a lese a 1 2 1 SS 100 HALCOMM AND ULTRA SITE WIRING LAYOUTS tse a RL 2 ZONEIGURING THE SS UM san 4 Su RE SAA M
4. E UM A 5 3 2 SETTIING THE SERVER PROPERTIES LE ea ae ld e de e o ll e de 5 3 3 SETTING THE PORT PROPERTIES FOR ULTRASITE AND HALCOMM IN 0 0 6 De Ae E ee 6 A y AAA ee ee ECR ERO E Ru ae TURE Re AIR Ae A 7 PREECE AT ne Ur OE OO 8 4 12 UETRASITE gt 2 SETUP AS ALARM RECEIVER FOR SLU Bi RA M Ree arn NOR URS 8 RL VP OUD ESOO AAA AA st eae A da 8 RO REN GA EE EE ec 8 Zo JG A II II A ST 8 MA a a ne a e e e ER 9 SS 100 Serial Server e V 1 Installing the SS 100 The CPC SS 100 Serial Server P N 570 2000 1s a device that allows Retail Solutions REFLECS controllers RMCC BEC or BCU to communicate over a TCP IP Ethernet network using the controller s serial port Tra ditionally REFLECS controllers have relied on a modem or a serial cable connection With an SS 100 installed the REFLECS can be in tegrated with a company s existing LAN or WAN A kit is included with the SS 100 which consists of e 5V power supply e 9 pin DB9 to 9 pin connector e 9 pin to 25 pin DB25 connector STC 10 DB serial cable e 535 1190 DB9 computer to REFLECS controller laptop cable UltraSite connection only DB25 null modem adapter HALComm connection only DB9 female female STC gender changer HAL Comm connection only
5. VAC SVDC power transformer into the SS 100 SS 100 Serial Server BEG SS 100 Wiring Requirements 3 3 Configuring the SS 100 l IMPORTANT Download the latest version of EZWebCon from the Lantronix Web site www lantronix com 2 Connectthe SS 100 to the LAN and power up the unit 3 Open EZWebCon on your computer which must also be connected to the LAN and click the bin oculars icon outlined in red to find the allocated IP address of the SS 100 I EZwebCon Y3 0 4 The Lantronix Device Configurator File Edit View Action Help Last Login Firmware IP Address Device Configurator Search Tool Outlined u NOTE A search will locate all SS 100s on the 4 network Use the MAC address located on the back of the SS 100 to find the correct SS 100 in the list 4 Choose the correct device on the Browse Net work screen and then click Ok 4 55 100 HALComm and UltraSite Wiring Layouts ES Browse Network ES Get More Servers Filter All Servers 7 MSS 212055 55100 10 10 84 41 MSS 211F4C MS8100 10 10 64 105 Choose and Highlight the Device 5 Verify that the firmware version number in the Firmware column is 3 6 9 If the firmware version shows any other number than 3 6 9 the SS 100 is the wrong version contact Technical Service for instructions on upgrading If the Firmware version is correct proceed to step 6 6 Highlight the device and select Action Man
6. XT gt SET DATA O MENU BEC Communications Setup Screen 3 Set LAN Adapter as the Dial out Device 4 Press 0 to go back to the Configuration screen 5 Press 3 System Information to open the BEC System Information screen 6 Press the down arrow once and the second BEC System Information screen is displayed C SYSTEM INFORMATION one number 1 m AUTOMATIC USA 04 06 97 10 26 97 O MENU DST MANUAL SET FND T PREV gt SET DATA BEC System Information Screen 7 Enter the Dial Strings in the Phone number 1 or the 2 field The format is IpAddressHost Name PortT For example if the UltraSite32 computer has a static IP address of 10 10 67 119 and it is listening on port 3026 then dial string would be 10 10 67 119 3026T Note that the dial string must end in the letter T 4 4 RMCC 1 Log on to the controller 2 From the Main Menu screen select 7 Configu ration to open the Configuration screen and 4 SS 100 Serial Server Remote Communication to access the Commu nications Setup screen Y Generic Modem String AT amp CT amp FEOSO 1 amp D2 Init String Init Response COMMUNICATIONS SETUP 12 00 UNITZ 02 Baud Rate 9600 N AT amp C18 amp W Dial out Device LAN Adapter Send Now NO Reset at Midnight N T PREV gt SET DATA O MENU RMCC Communications Setup Screen 3 Set LAN Adapter as the Dial out Device 4 Press 0 to go back to the Co
7. adio button under the Connection section along the bottom left of the screen Enter the IP address for the Lantronix in the Address field and 3001 in the Port field under Network Settings The site ID is used to match alarms to a site in the UltraSite32 database Enter a site ID in the Site ID field Note that the site ID you enter must be unique If the site ID entered is already assigned to another site you will be prompted to enter a different site ID number Do Not leave the Site ID field blank if left blank no prompts to enter a different site ID number will appear but the alarm receiving will not function correctly Connect to the site and do a site inventory This will send the site ID to the Reflecs box Note Be aware that if any user connects to this site from their own stand alone UltraSite32 and they have a site ID configured the site ID in the Reflecs will be overwritten This will effectively break the alarm receiver setup Although not manda tory an access code could be set up for the site as a security measure 8 UltraSite32 Setup as Alarm Receiver for 55 100 7 Open regedit from the Start menu and navigate to HKEY_CURRENT_USER Soft ware CPC UltraSite32 Network Add a new dword value called ReflecsSerialGatewayLis tenPort and set it to the value of the port chosen 8 Close and restart UltraSite to save port settings 4 1 1 Close and restart UltraSite 32 if error messages regarding failure
8. age from the drop down menu to open the Home screen S EZWebCon V3 0 4 The Lantronix Device Configurator File Edit View A Name MSS 52650AC Assign IP Address Manage Firmware IP Address Reload Firmware 20 W3 6 4 10 10 64 20 Get Configuration Set Configuration Telnet Reboot Device 110 10 64 20 Mss oo Action Menu Displayed 7 When any of the links along the left hand side of the screen are clicked the first time you are prompted to the Password screen enter the pass 026 1607 Rev 4 07 APR 2010 word system is the default password and click Login SETTINGS 22 LANTRONIX V Specdy IP Address Obten IP on boot via server Lantronix 55100 Y TETT T MSS 211F4C at 10 10 64 105 f LANTRONIX DHCP Subnet Mask ss 255 248 0 O Authentication Required Gateway Address TEEI 5 Pad Props Backup Gateway ooo Enter your password Home TCP Enabled Login PET ERE TENUES Enable WINS TEPIP Counters Received Sent ies TCP Messages 38 1 Port Properties Emvabd Packets 4 0 Tech Support CMP Messages 0 Home Retransmision Seconds Sence Zeroed Connect Fadure Reasons Invabd Packet Reasons Reasons Password Screen TE TNR Update Server Settings ew NOTE The Password screen appears only TCP IP Settings once per se
9. d of DB 25 DB 9 STC adapter to the 25 pin male end of the DB 25 null modem adapter NOTE Using a DB 25 DB 9 female female 4 null modem cable not provided to connect the SS 100 to the Modem port on the HAL Comm controller will eliminate steps 2 6 2 SS 100 HALComm and UltraSite Wiring Layouts www NOTE Screws on the DB25 null modem adapter may need to be reversed for a correct connection with the DB25 DB9 STC adapter Connect female end of the 10 serial cable to the male end of DB 25 DB 9 STC adapter 4 Connect DB 9 female female STC gender changer to the male end of the 10 serial cable 5 Connect the other end of the DB 9 female female STC gender changer to the male 9 pin Modem port of the HALComm 6 Usea standard ethernet cable to attach the SS 100 to an active hub of your TCP IP network 026 1607 Rev 4 07 APR 2010 7 Plug 110VAC SVDC power transformer into the SS 100 ETHERNET HUB gt LIE zy 0100 ETHERNET l LAPTOP CABLE CABLE 535 1190 DB9 LI ETHERNET em CABLE Ew IBM Compatible RMCC Wiring Layout with UltraSite SS 100 to Reflecs Steps 1 Connect the 25 pin end of the D25 DB9 straight through connector to the SS 100 2 Connect the 9 pin female end of the laptop cable to the straight through serial connector 3 Connect the SS 100 to the hub using the RJ 45 able 4 Plug the 4 position plugable connector into the Reflecs controller 5 Plug 110
10. edecated Host IP address COUNTERS Seconds Since Zeroed 95511 Frammg Errori Local ccesses Panty Errors Remote Accesses Chrerrun Erori Erpe Current Sermon Sermon Lini Flow Onl Violations Bytes Input Bytes upu Output Flow Control DTE ETS Update Porn Sales 1 Serial Port Settings Screen for UltraSite e Setthe Flow drop down list to ctsrts e Check the Inactivity Logout and Modem Emulation boxes e Click the Update Port Settings button e Click the Go back link to save the settings and go back to the Serial Port Settings screen The form produced the following error s Info Autostart character overrides normal Autostart Info Autostart overrides autostart character Go back Go Back Screen e Uncheck the DSR Logout and Wait boxes e Click the Update Port Settings button 6 Setting the Port Properties for UltraSite and HALComm in Lantronix 026 1607 Rev 4 07 APR 2010 3 3 2 HALComm e Verify that the DSR Logout and DTR Wait boxes now checked If using HALComm set the following parameters on the Lantronix SERIAL PORT SETTINGS Local Port 1 Status Mode Speed Char Stop Pan Incoming Pas Signal Chec PF DTE Wait F Modem Emulation Password Modem Control Passflow Local Switch None HALCOMM Forward Switch None SETTINGS Backward Switch Mone Break Control local Start Character 4 Terminal Type None CONNECTION I Autostart D
11. edicated Host IPaddress COUNTERS seconds Since Zeroed 1435 Framing Errors Local Accesses 1 Panty Errors Remote Accesses 0 Overrun Errors Sessions 0 Current Session Session Lumut 4 Flow Ctrl Violations Bytes Input Bytes Output Input Flow Control Ho Output Flow Control DSR No DTR CTS ETS CD Ho Update Port Settings Serial Port Settings Screen for HALComm e Setthe Flow drop down list to ctsrts e Check the Inactivity Logout and Modem Emulation boxes e an A in the Start Character field Click the Update Port Settings button e Click the Go back link to save the settings and go back to the Serial Port Settings screen The form produced the following error s Info Autostart character overrides normal Autostart Info Autostart overrides autostart character Go back Go Back Screen SS 100 Serial Server Configuring the 55 100 7 4 4 1 Reflecs UltraSite32 Setup as Alarm Re ceiver for SS 100 Open UltraSite32 and add a site for the Reflecs controller that will be connected via Lantronix Right click on a site in the Tree View and select Edit Communications Information to open the Edit Site screen Devices ER EINSTEIN REFLECS Enhanced REFLECS Standandl Connechon Modem C Direct Connect Network Server C Sens Network Server f Network Senal Gateway Edit Site Screen in UltraSite Select the Network Serial Gateway r
12. nfiguration screen 5 Press 3 System Information to open the RMCC System Information screen 6 Press the down arrow five times and the Dialout Setup screen is displayed DIALOUT SETUP 12 00 Change Baud Rate when dial to 9600 NO Day Phones 1 2 a Night Phones La 2 Use From NONE to NONE T PREV J NEXT gt SET DATA O MENU RMCC Dialout Screen 7 Enter the Dial Strings in the Day Phones 1 or 2 fields or the Night Phones 1 or 2 fields The for mat is IpAddressHostName PortT For exam ple if the UltraSite32 computer has a static IP address of 10 10 67 119 and it is listening on port 3026 then dial string would be 10 10 67 119 3026T Note that the dial string must end in the letter T Reflecs 9
13. r Properties 1 Click the Server Properties link from the list along the left hand side of the screen SS 100 Serial Server Configuring the SS 100 5 2 Set the Port Inactivity Timeout to 5 minutes under Server Settings and click the Update Server Settings button LANTRONIX M35100 PROTOCOLS TCPIP Enabled BOOT FARAMETERS Address bti automatic ly on boci ma 0106420 I RARP I BEOCOTP DHCP TFTP Loadhost DER Backup TFTP Loadhost janon Hetware Loadhort soo TA Sofware File Mal SS Startap File Snte SERVER PROPERTIES SERVER SETTINGS SETTINGS Server Pert Inactmty Timeout 5 Reboot Server Reload Firmware Reset to Factory Defaults eri ates pet D Update Serr Setings Server Settings Outlined in Red 3 3 Setting the Port Properties for UltraSite and HALComm in Lantronix 3 3 1 UltraSite 1 Click the Port Properties link above graphic from the list along the left hand side of the screen If using UltraSite set the following parameters on the Lantronix ULTRASITE SERIAL PORT SETTINGS SETTINGS Part Status Speed Char Step Parity seo lalo Modem Control Modem Emulanon CONNECTION Local Swatch Forward Suntech Backward Switch Break Control Autostart with Characters Autostart wth Characters Daterend Characters Datarend Tuner Idle Datasend Timer Frame Termunal Type D
14. ssion Specify the IP address B Set RARP BOOTP and DHCP as specified by the Network Administrator Enabling these set 3 1 TCP IP Setup tings may randomly change the IP address on boot up 1 Click the TCP IP link from the list along the left ee Address field specific to the customer s network as specified by the Network Administrator hand side of the Home screen D Configure the subnet mask in the Gateway Address field specific to the customer s network as specified by the Network Administrator wa BANTRONIX Server Name MSS 211F4C we Boot Code Version V1 2 April 12 1999 Firmware Version Version V3 6 8 010807 E Configure backup gateway in the Backup Gate Uptime 1 01 55 m Hardware Address 00 80 a3 21 1f 4c way field specific to the customer s network as PAP IP Address 10 10 64 105 Netware Subnet Mask 255 255 240 0 specified by the Network Administrator Tues F Click Update Server Settings to save the TCP IP configuration Select from the menu PROTOCOLS above to modify TCPAP IPX LAT server configuration Enabled Enabled Enabled www NOTE The IP address of the device has now Home Screen changed To connect to the new IP address the IP add into the b 2 2 Contact your Network Administrator to go GUY UIT CE GSS LORD SE INDIE through the following steps Steps correspond to letters A B C D E and F on the graphic below 3 2 Settingthe Serve
15. to open a listening port appear This message indicates the port number is currently in use by another PC Change the port number to one that is not in use Troubleshooting 4 2 BCU 1 Log on to the controller 2 From the Main Menu screen select 7 BCU Con fig to open the Configuration screen and 5 Remote Comm to access the RS 232 Communi cations Setup screen 12 00 Data B1ts 8 RS 232 COMMUNICATIONS SETUP ID 02 BAUD 9600 Dialout Delay Dialout Phone Dial out Device T PREV J NEXT LAN Adapter gt SET DATA O MENU RS 232 Communications Setup Screen 3 Set LAN Adapter as the Dial out Device 4 Enter the Dial Strings in the Dialout Phone 1 or the 2 field The format is IpAddressHost Name PortT For example if the UltraSite32 computer has a static IP address of 10 10 67 119 and it is listening on port 3026 then the dial string would be 10 10 67 119 3026T Note that the dial string must end in the letter T 4 3 1 Log on to the controller 2 From the Main Menu screen select 7 Configu ration to open the Configuration screen and 5 026 1607 Rev 4 07 APR 2010 Communications to access the Communications Setup screen COMMUNICATIONS SETUP 12 00 UNITZ 02 Baud Rate 9600 N Generic Modem String AT amp CT amp FEOSO 1 amp D2 Init String AT amp C1 amp W Dial out Device LAN Adapter Send Now NO Reset at Midnight N Init Response T PREV J NE

Download Pdf Manuals

image

Related Search

Related Contents

Child friendly programmable floor robot USER GUIDE  Differentiation of Radionuclides on Surfaces using Autoradiographic  Think Outside Stowaway 101797E User's Manual  Modelli 350, 377 MAG/SeaCore (Non ECT/ECT)  名和テクニカ 小型両替機代理店システム  CD Boombox with Bluetooth® Instruction Manual  camset33 - 2-channel video security door phone  Pen Tablet  施工説明書/取扱説明書  Specifications  