1. the source voltage and maximum load kVA conform to the nameplate rating on the front of the unit The unit is installed much like a transformer between the supply lines and the load s being protected as shown in Figure 2 4 4 1 Conduit Entry Exit Locations The conduit entry exit holes must be punched in the sides or back of the rear portion of the enclosure the side with the transformers so that the power conductors run to the circuit breaker and output lugs through the hole s provided in the barrier panel See Figure 2 NEUTRAL CONNECTION TO LOAD IF REQUIRED Output connections for units rated 500 A output TO LOAD current are made directly 3 phase source conductors f Must conform to nameplate voltage No phase order is necessary REMOTE ALARM to labeled transformer bus in the rear of the enclosure GROUND ATTENTION Conduit entry through the rear portion of the enclosure only ATTENTION Conduit entry through the rear portion of the enclosure only Figure 2 Electrical Connections 3 phase unit shown NOTE Each ac output power circuit shall be provided with overcurrent protection for all ungrounded conductors It is the responsibility of the purchaser to provide provisions for this overcurrent protection The overcurrent protection device shall be a circuit breaker or fuse for use as a branch circuit protection The voltage rating of the protective device for a three phase system shall b
2. 1449 2 cUL Canadian Standard C22 2 No 125 Complies with Part 15 Subpart J of FCC rules for a Class A computing device Nominal Voltages Agency Approvals Solatron Plus Series Instruction Manual 10 8 0 Maintenance WARNING All maintenance should be performed by qualified personnel only with the incoming power disconnected except as required to measure voltage Qualified personnel MUST be familiar with industrial electrical equipment and all safety precautions required to service such equipment The unit requires no maintenance when operating under proper environmental conditions If the unit is equipped with fans for forced air cooling the air intake filters must be checked once per month and cleaned if necessary 9 0 Warranty 9 1 Warranty Information Please see the Terms amp Conditions of Sale Solatron Plus Series Instruction Manual 11 SOLAD www solahd com 800 377 4384 847 268 6651 solahd technicalservices Qemerson com A e EMERSON Industrial Automation Part Number A272 094 Rev 5 February 2013
3. Manual iii 1 0 Important Safety Instructions This manual contains important safety instructions that should be followed during the installation of the Solatron Plus Please read all safety installation and operating instructions before attempting to install or operate the unit 1 1 Safety Precautions Warnings The unit must be installed and accessed by qualified personnel only Disconnect incoming power while installing the unit and before accessing the interior of the enclosure The unit contains components which are at line voltage with or without a load being supplied All enclosures must be grounded using the provided grounding lugs and or studs Applicable National Electrical Codes and local codes must be observed 2 0 Warnings Defined A DANGER Indicates an imminently hazardous situation that if not avoided will result in death or serious injury This signal word is limited to the most extreme situations A WARNING Indicates a potentially hazardous situation that if not avoided could result in death or serious injury A CAUTION Indicates a potentially hazardous situation that if not avoided may result in minor or moderate injury It may also be used to alert against unsafe practices Solatron Plus Series Instruction Manual 4 3 0 Introduction The SolaHD Solatron Plus Series is designed to provide a tightly regulated isolated voltage source to sensitive loads It increases reliability by impr
4. SOLAD Three Phase Power Conditioner Solatron Plus Series Instruction Manual While every precaution has been taken to ensure accuracy and completeness in this manual EGS Electrical Group LLC assumes no responsibility and disclaims all liability for damages resulting from use of this information or for any errors or omissions The SolaHD and Emerson logos are registered in the U S Patent and Trademark Office All other product or service names are the property of their registered owners 2013 EGS Electrical Group LLC All rights reserved Specifications are subject to change without notice Solatron Plus Series Instruction Manual ii 1 0 Important Safety Instructions 1 4 Safety Precautloris eese erronee rotate ttis ep kehana tan Giele ege E da kal Sege 2 0 Warnings Defined 5 1 erento nre cei tense n end ta nest beban concen un 4 3 0 Fiere m 5 9 1 NEEN 5 4 0 Installation Instructions een 6 Ee Ee le BE 6 4 2 fe Taro 6 4 3 Environmental EE 6 EE eelere e ene 7 GET E 8 5 0 Diagnostics 8 ef fe oz ro Lights Jeena EC 8 Ewe Tu EE 9 6 0 Troubleshooting eese nennen nnne nnne nnne nenne nnns 9 FAIETuIdgcupLA 10 8 0 Mamtenance Lae 11 9 0 Warranty ET 11 9 1 Warranty tute Ee WEE 11 Solatron Plus Series Instruction
5. e based on the phase to phase voltage The rating of the overcurrent protective device must meet the requirements of the National Electrical Code Article 240 Failure to accomplish this will void the UL1012 listing Solatron Plus Series Instruction Manual 7 4 4 2 Lug Size Table per phase EEN 208 240 V 480 600 V 208 240 V 480 600 V om 10 1 0 10 1 0 14 2 0 14 2 0 HEJ 14 4 0 10 1 0 14 2 0 14 2 0 Three Phase HEN 14 4 0 10 1 0 14 2 0 14 2 0 14 4 0 10 1 0 2 6 350 14 2 0 NOTE All lugs accept Al Cu wire 4 5 Startup Power may be applied to the unit AFTER the following conditions have been met All power and ground cable connections have been secured The enclosure has been closed The circuit breaker operating mechanism is in the OFF open position The smaller auxiliary circuit breakers should be in the ON closed position 5 0 Diagnostics 5 1 Indicator Lights The unit contains 3 indicator lights on the front panel and a remote alarm relay 5 1 1 Green Light Condition normal The remote alarm relay is open 5 1 2 Middle Amber Light Atransformer over temperature has been detected The output voltage is not regulated under this condition in order to minimize transformer losses The remote alarm relay is closed In order to reset this condition the unit must be turned off allowed to return to normal temperature and then turned back on Check to ensure the load KVA does not exceed
6. eck the source voltage Input circuit breaker trips Ensure continuous load KVA does not exceed nameplate kVA Green light out amber light lit See 5 0 Diagnostics For further assistance please contact SolaHD Technical Support at 800 377 4384 847 268 6651 or by e mail at solahd technicalservices emerson com Solatron Plus Series Instruction Manual 9 7 0 Specifications ELECTRICAL Power Ratings 20 30 50 75 KVA Three phase 63TAA3 units 63TCA3 units 63TCC3 units 63TDA3 units 208 V ac input 480 V ac input 480 V ac input 600 V ac input 208 Y 120 V ac 208 Y 120 V ac 480 Y 277 Vac 280 Y 120 V ac output 60 Hz output 60 Hz output 60 Hz output 60 Hz 25 to 10 of nominal rated voltage sr Overload Capacity 1000 of rated load for 1 s 200 of rated load for 1 min Output voltage will switch to bypass mode when input Under Voltage is less than 50 of nominal Regulated output voltage will be re established once input voltage is within specifications Short Circuit Input circuit breaker Amber lamp indication of over temperature at Over temperature approximately 180 C Unit switches to bypass mode until internal temperature is reduced to specified value Dimensions in mm H 42 in 1016 mm W 28 in 712 mm D 26 in 661 mm Weight Ib kg 20 kVA 30 kVA 50 kVa 75 KVA OMG 10 AKO 600 Ib 273 kg 750 Ib 341 kg 950 Ib 432 kg 1200 Ib 545 kg UL1012 UL
7. oving efficiency and extending the useful life of protected loads Input voltages from 25 to 10 are corrected to 3 of nominal voltage with a response time of 1 5 cycle typical Output voltage regulation is accomplished by using silicon rectifier switches and a multi tap transformer arrangement Tap transitions are made in a secondary control circuit and at less than full load current eliminating voltage notching during each transition 3 1 Features Rugged Construction All magnetic and electronic components have been designed to insure that the Solatron Plus will provide the specified voltage regulation to the most demanding electrical loads Protection All units protect against system transients and overvoltages using a Surge Protection Device minimum 80 kA surge current rating No Harmonic Interactions The unit is unaffected by harmonic voltages and currents and produces no distortion during normal operation High Overload Capacity Motor starting and momentary overloads will not trip the unit and output short circuits will not damage the unit Diagnostic Display Panel mounted indicating lights for bypass and high temperature conditions Fail Safe Bypass SCR power supply and other component failures will result in an automatic electronic bypass with no interruption to the load nominal input output voltage with isolation and surge suppression active Solatron Plus Series Instruction Manual 5 4 0 In
8. stallation Instructions 4 1 Unpacking Upon receipt of the unit immediately inspect the enclosure s and contents for obvious signs of damage and or mishandling loose parts enclosure dents or holes If damaged photograph the unit inform the carrier and contact SolaHD for a Return Material Authorization RMA number 4 2 Mounting The unit must be mounted on a concrete floor or other non flammable surface The minimum spacing around the enclosure must be as indicated in Figure 1 to ensure adequate ventilation 12 minimum clearance top 4 minimum Ea clearance 4 minimum back clearance both sides Figure 1 Minimum spacing requirement excluding spacing required for condit entry exit 4 3 Environmental The following environmental conditions must be met Ambient Temperature 0 C 40 C 32 F 104 F e Relative Humidity 95 non condensing e Surrounding air free of flammable or combustible materials Enclosure not subjected to falling or splashing water unless specific precautions have been taken to protect the unit i e NEMA3 or 3R enclosure WARNING Failure to comply with the above environmental conditions voids the warranty Solatron Plus Series Instruction Manual 6 4 4 Electrical Connections The unit is designed to operate from a voltage source as indicated on the name plate and to power loads where maximum continuous kVA does not exceed the nameplate indication Ensure that
9. the nameplate kVA Make sure the ambient temperature does not exceed 40 C 5 1 3 Right Amber Light The unit has gone into bypass due to a failed SCR or firing board malfunction Under this condition the unit will not regulate the output voltage The remote alarm relay is closed the unit needs to be reset See 5 1 4 A qualified electri cian should determine whether there is a permanent problem Solatron Plus Series Instruction Manual 8 5 1 4 Reset the Auxiliary Breaker 1 Open the main circuit breaker 2 Remove the front cover 3 Reset the auxiliary breaker by opening and closing the breaker so both breaker handles are in the up position A Replace the front cover g Close the input circuit breaker 9 If the unit auto bypasses immediately or after a short period of time the unit requires service Call SolaHD Technical Service at 800 377 4384 for assistance 5 2 Remote Alarm The unit is equipped with a normally closed remote alarm contact rated 0 6 A 120 V ac accessible at TB1 next to the output connector block The alarm contact will be CLOSED under the following circumstances 1 There is no power applied to the unit 2 Power is applied but the main input circuit breaker is open 3 The power supply has failed 4 There is an over temperature condition or the unit has auto bypassed 6 0 Troubleshooting Problem Required Action gege are ESE power fe Ensure the circuit breaker is ON Ch