1. manual contains important safety instructions that should be followed during the installation and operation of your UPS Please read all safety installation and operating instructions before attempting to install or operate the UPS Please adhere to all warnings on the unit and in this manual during installation and operation 1 1 SAFETY PRECAUTIONS SAVE THESE INSTRUCTIONS WARNING The UPS is intended for installation in a controlled environment WARNING Fuses To reduce the risk of fire replace only with the same type and rating of fuse CAUTION To reduce the risk of fire connect only to a circuit provided with 20 amperes maximum branch circuit overcurrent protection in accordance with the National Electric Code ANSI NFPA 70 CAUTION UPS with Internal Batteries Risk of electric shock Hazardous live parts inside this unit are energized from the battery supply even when the input ac power is disconnected CAUTION No User serviceable Parts Risk of electric shock Do not remove the cover no user seviceable parts inside Please refer all repairs to a qualified service technician CAUTION Risk of electric shock Disconnect the UPS from the mains supply before installing a computer interface signal cable Reconnect the power cord only after signaling interconnections are made CAUTION Non isolated Battery Supply Risk of electric shock The battery circuit is not isolated from the ac input Hazardous voltage may exist betwe
2. SOLAHD Uninterruptible Power Systems Instruction Manual While every precaution has been taken to ensure accuracy and completeness in this manual EGS Electrical Group LLC assumes no responsibility and disclaims all liability for damages resulting from use of this information or for any errors or omissions 2009 EGS Electrical Group LLC All rights reserved Specifications are subject to change without notice SolaHD name and logo are registered trademarks of EGS Electrical Group LLC All names referred to are trademarks or registered trademarks of their respective owners Visit our Web site at www solahd com S3K Series Instruction Manual ii Table of Contents 1 0 2 0 3 0 4 0 5 0 6 0 7 0 8 0 9 0 10 0 11 0 Important Safety Instructions sssrini eaaa ias 4 Product DESGMPUON cesar ic 5 6 Pres InstallatiOn corso it idad 7 Installation coin arrasar tos 7 8 Operation rd chee 9 10 AANINS ill i as 10 Software amp IMISM ACE eiii eodace casi Ohta EMA 11 12 Maintenance 8 Storage insnenneneennannaanannanananaanaaa annae 12 Trouble hootihgi cicle E 13 SPeCiHiCallONnS aa 14 15 Registration amp Warranty meeerarseeenenennnneenenennanaanenen annae 15 Visit our Web site at www solahd com S3K Series Instruction Manual iii 1 0 IMPORTANT SAFETY INSTRUCTIONS Thank you for selecting the S3K Series Uninterruptible Power System UPS This
3. d by depressing the ON button for at least 3 seconds The load will be powered from the internal batteries until the discharge point is reached 5 2 Switch Off Hold the OFF button until the ON LINE or ON BATTERY LEDs are no longer illuminated 5 3 Silence When the UPS is in backup mode press the ON button for at least 1 second to silence the audible alarm This function is disabled when the UPS status is either LOW BATTERY or OVERLOAD Note In backup mode the UPS will automatically turn off if the connected loads are not operating 5 4 Self test Use the self test function to verify both the operation of the UPS and the condi tion of the batteries With normal utility power push the ON TEST button for at least 1 second During the self test the UPS operates in backup mode green LED is illuminated If the UPS passes the self test it returns to line interactive mode The ON BATTERY LED goes off and the ON LINE LED goes on steadily If the UPS has failed to pass the self test it returns to line interactive mode and the REPLACE BATTERY LED illuminates The loads are not affected Recharge the batteries overnight and perform the self test again If the REPLACE BATTERY LED is still on contact your local SolaHD distributor for a replacement Note When replacing the internal batteries 12 V 7 Ah disconnect utility power before opening the case Take note of the polarity before installing the new batteries to avoid a sh
4. en the battery terminals and the ground test before touching CAUTION Servicing of batteries should be performed or supervised by personnel knowledgeable in batteries and the required precautions Keep unauthorized personnel away from the batteries CAUTION A battery can present a risk of electric shock and high short circuit current The following precautions should be observed when working on batteries e Remove watches rings or other metal objects e Use tools with insulated handles CAUTION Do not open or mutilate the battery Released electrolyte is harmful to the skin and eyes and may be toxic CAUTION Do not dispose of batteries in a fire they may explode CAUTION When replacing batteries replace with the same number and type Visit our Web site at www solahd com S3K Series Instruction Manual 4 2 0 Product Description 2 1 Front Panel BATTERY CHARGE ON TEST LOAD POWER OFF Paco ee REPLACE BATTERY gt ON BATTERY VOLTAGE REDUCTION VOLTAGE BOOST ON LINE ON TEST Button Turns on the UPS to power the loads It also activates the UPS self test OFF Button Turns off the UPS and the loads REPLACE BATTERY Indicator Red LED The LED illuminates when the UPS battery is no longer useful and must be replaced VOLTAGE BOOST Indicator Yellow LED The LED illuminates when the UPS is correcting a low utility voltage condition The loads will continue to receive normal po
5. les connected to the REMOTE PORT e During extended storage in environments where the ambient temperature is 15 C to 30 C 5 F to 86 F charge the UPS s batteries every 6 months 30 C to 45 C 86 F to 113 F charge the UPS s batteries every 3 months Visit our Web site at www solahd com S3K Series Instruction Manual 12 9 0 Troubleshooting tk id Check the input power source source Replace fuse with same type Fuseblownion teak patel and rating and check load UPS won t operate after sing the ON TEST or OFF ON TEST button was not Press the ON TEST button for pressed for 1 seconds more than 2 seconds No LEDs no warning sounds Turn off UPS Remove all loads to ensure there are no problems or internal short circuits Press the ON TEST button for more than 2 seconds No power source input Check the input power source Indicates no utility with a warning every few seconds Fuse blown on rear panel Replace fuse with same type and rating and check load Fault light is on and the alarm A Contact your distributor or Tech E UPS needs repair A a keeps beeping nical Support for assistance Continuous beeping Overload condition Removetie KAAS rela the output specifications ee A A Replace fuse with same type Utility indicator light is on Fuse blown on the rear panel and rating and check load Batteries are not fully charged Resnetge the UPS tot avlenst 4 hours Check the load power display UPS has reduced battery
6. mmon referenced supply no greater than 40 V dc The transistors are capable of a maximum non inductive dc load of 25 mA Use only pin 4 as the common Battery low Generates a high to low signal when the internal battery of the UPS has less than 5 minutes of backup time remaining Notes Normally open status closed when active Open collector output must be pulled up to a common referenced supply no greater than 40 V dc The transistors are capable of a maximum non inductive dc load of 25 mA Use only pin 4 as the common Output Remote shutdown of the UPS Notes PIN 6 has a multi purpose functionality 1 Will shut down the UPS when a high RS 232 level is sustained on PIN 6 for 0 36 seconds 2 Is the RS 232 data input R x D Keep this pin at high voltage 5 V to 12 V for 500 ms to shutdown the UPS Activates when in the battery mode only fF RS 232 data output Output Note PINS 2 and 5 rating 40 V dc 25 mA non inductive 8 0 Maintenance 8 Storage 8 1 Maintenance e Keep the unit clean wipe with a soft damp cloth and vacuum the ventilation intake periodically e Check for loose and bad connections monthly 8 2 Storage Conditions e Before storing charge the UPS s batteries for at least 4 hours e Store the UPS covered and upright in a cool dry location with the batteries fully charged To avoid unnecessary draining of the batteries remove any accessories in the accessory slot and disconnect any cab
7. ort circuit 5 5 Load Power Bar Graph The 5 LED display shows the power drawn from the UPS by the load The display indicates the percentage of the UPS s rated capacity For example If three LEDs are lit the load is drawing between 50 and 67 of the UPS s capacity If the UPS is overloaded the overload LED illuminates and the alarm sounds Visit our Web site at www solahd com S3K Series Instruction Manual 9 5 6 Battery Charge Bar Graph The 5 LED display shows the present charge of the UPS s batteries as a percentage of the batteries capacity When all five LEDs are illuminated the batteries are fully charged When only two LEDs are illuminated the batteries can supply less than 2 minutes of run time for the load 5 7 Cold Start When the UPS is off and there is no utility power you can use the cold start feature to apply power to the loads from the UPS s batteries Press the ON TEST button until the UPS beeps 5 8 Shutdown Mode In shutdown mode the UPS stops supplying power to the load and waits for the return of utility power If there is no utility power present external devices e g servers connected to the computer interface can command the UPS to shutdown This is normally done to preserve battery capacity after the graceful shutdown of protected servers The UPS will scroll the front panel indicators sequentially in shutdown mode 6 0 Alarms 6 1 Backup slow beeping When the UPS is operating in back
8. plugged into an improperly wired ac power outlet Detected wiring faults include ground and hot neutral polarity reversal 4 2 6 Connect the Telephone or Modem if applicable Connect the source line to the IN connector Connect the equipment to the OUT connector CAUTION To reduce the risk of fire use only No 26 AWG or larger telecommu nication line cord 4 2 7 Connect Computer Interface UPSMON software or other power management software and an optional interface kit can be used with this UPS If used connect the interface cable to the REMOTE PORT on the rear panel of the UPS and to the host computer either COM 1 or COM 2 CAUTION Use only factory supplied or authorized UPS interface cables Note Computer interface connection is optional The UPS works properly without a computer interface connection Note Only use kits supplied or approved by the manufacturer 4 2 8 Install the Optional NETpower Card S3K1600 Models Only Remove the SNMP port cover Insert the NETpower card P N SNMPCARDPC and secure with screws Use network cables supplied by user to connect the UPS to the computer network port Please refer to the NETpower card CD ROM for configuration settings and further instructions Visit our Web site at www solahd com S3K Series Instruction Manual 8 5 0 Operation 5 1 Switch On Press the ON button for at least 0 5 seconds Note If normal utility power is not present the UPS may be engage
9. ter plungers of the fuse will extend when tripped SITE WIRING FAULT Indicator Red LED The LED illuminates when the UPS is connected to an improperly wired ac power outlet REMOTE PORT Computer Interface Provides both RS 232 and relay signals to support Windows applications and other OS compatible solutions SNMP PORT COVER S3K1600 Models Only Remove the cover to insert the NETpower card P N SNMPCARDPO Visit our Web site at www solahd com S3K Series Instruction Manual 6 3 0 Pre Installation Inspect the UPS upon receipt Damage that may have occurred in transit is not covered under the warranty If shipping damage is present please contact your local carrier and SolaHD distributor immediately Note The packaging material is recyclable Please reuse or dispose of it in a responsible manner 4 0 Installation 4 1 Installation Requirements e Install the UPS in a protected area with adequate ventilation and free from excessive dust Do not expose the UPS to corrosive air e Avoid direct sunlight rain and high humidity e Do not operate the UPS where the temperature and humidity are out of the specified limits operating temperature 0 C to 40 C humidity 0 to 95 Keep away from fire and extremely hot locations e Maintain a clearance of 4 inches 100 mm between the UPS rear panel and the wall and 1 inch 25 4 mm between the UPS sides and the wall Keep the air inlets unobstructed to facilitate ventila
10. time UPS overload ee any non essential Replace the batteries Contact your distributor or Technical Support for assistance Voltage of batteries is too low lcd tie UPSforatleast Battery light flashes when power of UPS is supplied by Batteries are disconnected Check the connections tilit S Damage present on battery Replace the battery packs packs immediately For further assistance please contact SolaHD Technical Support at U S 800 377 4384 International 847 268 6651 E mail tech solahd com Output short circuit or overload on UPS Batteries are aged and can t be fully charged Visit our Web site at www solahd com S3K Series Instruction Manual 13 10 0 Specifications Catalog Number Parameter S3K700 S3K1000 S3K1600 1440 VAJIZ00 0 Nominal Voltage 120 V 25 single phase Frequency 50 or 60 Hz 5 auto sensing OUTPUT Voltage on battery Pure sine wave output at nominal 5 Frequency on battery 50 or 60 Hz 0 5 Voltage Regulation AVR automatically increases output voltage 15 above input voltage if AVR 9 9 to 25 of nominal is detected AVR decreases output voltage 15 below input voltage if 9 to 25 of nominal is detected PROTECTION 8 FILTERING Spike Protection 320 J 2 ms Fuse for overload amp short circuit protection EMI RFI Filter 10 dB at 0 15 MHz 50 dB at 30 MHz UPS automatically shuts down if overload exceeds 100 of nominal at 20 s and 125 at 2 s Short Circuit UPS o
11. tion and heat dissipation e Do not stack materials on top of the UPS e Never leave the UPS on an uneven surface 4 2 Installation Instructions 4 2 1 Connect to Utility Power Connect the UPS line cord to the IEC INPUT receptacle on the rear panel of the UPS line cord already attached on S3K1600 models Connect the other end of the line cord to the ac input power outlet 4 2 2 Charge the Battery The UPS charges its battery whenever it is connected to utility power even when the unit is off For best results charge the battery for 8 hours before initial use 4 2 3 Turn On the UPS Press the ON TEST button Visit our Web site at www solahd com S3K Series Instruction Manual 7 4 2 4 Connect the Loads Connect the loads to the OUTPUT receptacles on the rear panel of the UPS CAUTION Never connect a laser printer or plotter to the UPS with other computer equipment Laser printers and or plotters will require their own UPS as they periodically experience high inrush surge currents which may cause an overload Note Be careful not to overload the UPS An audible alarm will beep continu ously and the front panel OVERLOAD LED will illuminate to indicate an overload status The UPS will shut down automatically to protect its internal circuitry 4 2 5 Check the Site Wiring Fault Indicator After completing the above steps check the SITE WIRING FAULT indicator on the rear panel of the UPS A light will be present if the UPS is
12. twork management function which supports both SNMP and HTTP Features include multiple system shutdown event notification scheduling and control and configuration of the UPS remotely The NETpower card must be inserted into the SNMP PORT on the rear panel of the UPS Please refer to the NETpower card CD ROM for further instructions 7 3 Interface Kits optional Interface kits include a required interface cable to convert status signals from the UPS into signals which an individual operating system will recognize The interface cable must be connected to the REMOTE PORT on the rear panel of the UPS and to the host computer either COM 1 or COM 2 Please refer to the READ ME file for further instructions CAUTION Use only factory supplied or authorized UPS interface cables 7 4 Remote Port computer interface The REMOTE PORT on the rear panel of the UPS may be connected to a host computer to allow for UPS status monitoring and operation control Functions include e Broadcasting a warning when power fails e Closing any open file before the batteries are exhausted e Turning off the UPS Please refer to 7 4 1 on page 12 for Remote Port PIN Configurations Visit our Web site at www solahd com S3K Series Instruction Manual 11 7 4 1 Remote Port PIN Configurations Power fail Generates a high to low signal when the line fails Notes Normally open status closed when active Open collector output must be pulled up to a co
13. up mode the UPS will sound an audible alarm with a beep every four seconds The alarm stops when the UPS returns to the line interactive mode The alarm may be silence by pressing the ON TEST button while in backup mode Press the ON TEST button again to reactivate the sound 6 2 Low Battery rapid beeping In backup mode when the energy of batteries reaches lower levels about 20 30 the UPS beeps rapidly until it shuts down from battery exhaustion or returns to line interactive mode The low battery alarm cannot be silenced 6 3 Overload continuous beeping When the UPS output exceeds 100 of nominal for 20 seconds or 125 for 2 seconds an audible alarm will sound and the front panel OVERLOAD LED will illuminate The UPS will shut down automatically to protect its internal circuitry Visit our Web site at www solahd com S3K Series Instruction Manual 10 7 0 Software amp Interface 7 1 Power Monitoring Software UPSMON software or other power monitoring software utilizes a standard RS 232 interface to perform monitoring functions and an orderly shutdown of the protected equipment in the event of power failure UPSMON displays all the diagnostic symptoms on the monitor including voltage frequency and battery levels UPSMON is available for Windows applications and other OS compatible solutions 7 2 NETpower Card optional S3K1600 models only The NETpower card P N SNMPCARDPC provides an advanced yet easy to use ne
14. utput cuts off immediately or input fuse protection Maximum Elevation 10 000 ft 3 000 m Audible Noise lt 40 dBA lt 45 dBA 1 m from surface 1 m from surface PHYSICAL Dimensions W x D x H 5 5 x 17 2 x 8 27 6 7x 17 7x8 9 inches mm 140 x 436 x 210 170 x 450 x 226 Net Weight Ib kg 66 0 30 0 Shipping Weight Ib kg 70 4 32 0 Attached cord to 5 15P Output Receptacles 6 NEMA 5 15R Backup Time 10 30 min depending on the load Overload Protection Visit our Web site at www solahd com S3K Series Instruction Manual 14 Catalog Number Parameter S3K700 S3K1000 Backup Time at Full 5 min 3 5 min 3 min Load Backup Time at Half 14 min 12 5 min 10 min Load A NETpower card eine PIN SNMPCARDPC AGENCY APPROVALS Safety UL1778 CAN CSA C22 2 No 107 FCC Part 15 Subpart B Class B 1998 11 0 Registration amp Warranty 11 1 Product Registration To register your product for updates and information on service and support visit our Web site at http www solahd com support registration htm 11 2 Warranty Information Please see the enclosed Terms Conditions of Sale Visit our Web site at www solahd com S3K Series Instruction Manual 15 SOLAD Technical Support U S 800 377 4384 International 847 268 6651 E mail tech solahd com Web site www solahd com O EMERSON Industrial Automation Part Number A272 076 Rev 3 August 24 2009
15. wer BATTERY CHARGE Bar Graph The display shows the present battery charge as a percentage of the battery capacity LOAD POWER Bar Graph The display shows the power being drawn by the loads OVERLOAD Indicator Red LED The LED illuminates when the loads connected to the UPS exceed capacity ON BATTERY Indicator Green LED The LED illuminates when the UPS is supplying battery power to the loads VOLTAGE REDUCTION Indicator Yellow LED The LED illuminates when the UPS is correcting a high utility voltage condition The loads will continue to receive normal power ON LINE Indicator Green LED The LED illuminates when the line input voltage is normal Visit our Web site at www solahd com S3K Series Instruction Manual 5 2 2 Rear Panel W o Wo ara WIRING IN Our FAULT Ofeewe USB REMOTE OUTPUT 10 DD x WIRING O CIRCUIT a o FAULT o 7 BREAKER mn Os D De w D INPUT FUSE Ey O C D 50 o o y M3 SCREWS gI 2 E O SNMP PORT COVER o NP S3K700 8 S3K1000 S3K1600 IN OUT Telephone Modem Connector Provides surge suppression for tele phones and modems OUTPUT Output power receptacles for loads INPUT Ac input power receptacle line cord attached on S3K1600 models FUSE or CIRCUIT BREAKER Blows when the connected loads exceed the protected receptacle s capacity The cen