Home

Emerson NetSure 211 Series Ordering Guides

image

Contents

1. Shelf Size Step 1a Choose Rectifier Shelf includes SCU controller and space for distribution module 58213660001 NetSure 211 power system shelf 19 x 1 RU 58213660002 NetSure 211 power system shelf 23 x 1 RU Step 1b Select Distribution 1 required per rectifier shelf 582136600NG 10 GMT fuse output no LVD 582136600BG 10 GMT fuse output battery LVD Step 1c Select Line Cord 1 required per shelf 545478 14 AC cord 120 VAC 5 15P fits wall outlet 545252 14 AC cord 120 VAC twist lock L5 30P 540946 14 AC cord 208 240 VAC twist lock L6 30P This cord is for use with 1R48500 rectifiers and the 19 shelf only Step 1d Select up to 2 Temperature Probes if Required One Battery and One Ambient 58213660090 3 meter temperature probe 58213660091 10 meter temperature probe Step 1e Select Rectifier Quantity Up to 2 rectifiers per 19 shelf or Up to 3 rectifiers per 23 shelf 1R48500 500 watt 10 amp rectifier 1R481000 1000 watt 20 amp rectifier Note 1000 W rectifier de rates to 500 W with 120 volt AC input Step 1f Select Up to 10 Fuses if Required 248610301 0 18 A fuse 248610200 0 25 A fuse 248610300 0 5 A fuse 248610500 0 75 A fuse 248610700 1 33 A fuse 248610800 2 A fuse 248610900 3 Afuse 248611000 5 A fuse 248611300 7 5 A fuse 248611200 10 A fuse 248611500 15 A fuse max load of 70 or 10 5 A For add
2. LC Cannot be used in Lists NF and BF Step 2d Select Line Cord 2 required per shelf 545478 14 AC cord 120 VAC 5 15P fits wall outlet 545252 14 AC cord 120 VAC twist lock L5 30P 540946 14 AC cord 208 240 VAC twist lock L6 30P This cord is for use with 1R48500 rectifiers and the 19 shelf only Step 2e Select up to 2 Temperature Probes if Required one battery and one ambient or two battery 58213660090 3 meter temperature probe 58213660091 10 meter temperature probe Step 2f Select GMT Lead Assemblies if Using GMT Fuses in Distribution not required for 545332 58213660060 GMT lead assembly for 5 10 A GMT fuses 58213660061 GMT lead assembly for 8 10 A GMT fuses for lists NF and BF 58213660062 GMT lead assembly for 5 15 A GMT fuses for lists NF and BF Step 2g Select Rectifier Quantity Up to 4 rectifiers per 19 shelf or Up to 6 rectifiers per 23 shelf 1R48500 500 watt 10 amp rectifier 1R481000 1000 watt 20 amp rectifier Note 1000 watt rectifier de rates to 500 watts with 120 volt AC input For additional information or questions visit or call Web www EmersonEnergy com Tel 1 800 800 1280 USA and Canada O950RA NS211 0315 5 N Netsure 211 Ordering Guide S 48 VDC Power Solutions Mini System A EMERSON Network Power Configuration 2 continued Catalog Number Part Number Quantity Description Catalog Number Part Num
3. NetSure 211 Ordering Guide 48 VDC Power Solutions Mini System NetSure 211 Series The NetSure 211 Series of compact 48 VDC power systems com bines reliable rectifiers with an advanced Ethernet accessible controller Engineered for mini power applications the system is available in two models Both models feature centralized control flexible distribution and high power density for a range of DC applications The 1 RU model allows for up to three 1000 watt 48 VDC rectifiers for a total of 3000 watts of power conversion in 23 and up to 2000 watts in a 19 configuration The units include single AC feeds for 120 VAC or 208 240 VAC inputs The 2 RU model allows for up to six 1000 watt 48 VDC rectifiers for a total of 6000 watts of power conversion in 23 and up to 4000 watts in a 19 configura tion Dual AC feeds are available for 120 VAC or 208 240 VAC inputs Table of Contents Table A Calculate the Number of Batteries and Rectifiers Needed 2 Table B Select a System Based on the Number of Rectifiers amp Distribution Type REQUIFE c cccssscccssssecssteceseecessesesseseesssseeesssecesneeenes 2 Configuration 1 NetSure 211 1 RU Up to 40 A N 1 ceeeeeseeee 3 Configuration 2 NetSure 211 2 RU Up to 100 A N 1 eee 5 Note Click on the step above to jump to that page To return to the Table of Contents click on the main title of any page NetSure 211 23 Shelf 2 RU NetS
4. and Canada 4 O950RA NS211 0315 Netsure 211 Ordering Guide N EMERSON 48 VDC Power Solutions Mini System Nek Po NetSure 211 23 Shelf 2 RU NetSure 211 19 Shelf 2 RU Configuration 2 NetSure 211 2 RU Up to 100 A N 1 Catalog Number Part Number Quantity Description Shelf Size Step 2a Choose Rectifier Shelf includes ACU controller and space for distribution 58213660005 NetSure 211 power system shelf 19 x 2 RU 58213660006 NetSure 211 power system shelf 23 x 2 RU Step 2b Select Distribution 1 required per rectifier shelf 582136600NA 2 Load breaker positions 2 battery breaker positions and 5 GMT fuse positions 10 A max no LVD 582136600BA 2 Load breaker positions 2 battery breaker positions and 5 GMT fuse positions 10 A max battery LVD 582136600NC 4 Load breaker positions and 5 GMT fuse positions 10 A max no LVD 582136600BC 4 Load breaker positions and 5 GMT fuse positions 10 A max battery LVD 582136600LC 4 Load breaker positions and 5 GMT fuse positions 10 A max load LVD 582136600NF 5 10 A GMT fuse positions and 8 15 A GMT fuse positions no LVD 582136600BF 5 10 A GMT fuse positions and 8 15 A GMT fuse positions battery LVD Step 2c Select GMT Fuse Module if Required 545332 6 position GMT fuse position option board takes up 2 load breaker positions Note Up to 1 for Lists NA and BA Up to 2 for Lists NC BC
5. ber Quantity Description Step 2h Select Breakers if Required Step 2i Select Fuses if Required 101599 10 A breaker 248610301 0 18 A fuse 101600 15 A breaker 248610200 0 25 A fuse 101601 20 A breaker 248610300 0 5 A fuse 101602 25 A breaker 248610500 0 75 A fuse 101603 30 A breaker 248610700 1 33 A fuse 101604 35 A breaker 248610800 2 A fuse 101605 40 A breaker 248610900 3 A fuse 121997 45 A breaker 248611000 5 A fuse 101606 50 A breaker 248611300 7 5A fuse 101607 60 A breaker 248611200 10 A fuse 101608 70 A breaker 248611500 15 A fuse 101609 75 A breaker max load of 70 or 10 5A 121995 80 A breaker 101610 100 A breaker See System Application Guide for any spacing requirements Catalog Number Part Number Step 2j Select Battery Cables if Required Quantity Description 58213660065 2 AWG battery cable shelf side 58213660066 2 AWG battery cable battery side 58213660067 8 AWG battery cable shelf side connects to shelf and 554631 battery cabinet Step 2k Select Battery Cabinet if Required 554631 Wall or rack mounted battery cabinet holds 4 40 Amp hour M12V40F batteries Step 2l Select Battery Tray if Required 582136700SK001 19 battery tray that accepts M12V105FT batteries Kit includes tray battery disconnect box 100 A disconnect 582136700SK002 23 battery tray that accepts M12V155FT and M12V180FT batteri
6. es Kit includes tray battery disconnect box 100 A disconnect Step 2m Select Wall Mounting Kit if Required 553203 Wall mount kit allows power system shelf to mount flat to wall 552537 19 wall mount kit provides 6 RU of mounting space equipment mounts horizontally in rack 552535 23 wall mount kit provides 6 RU of mounting space equipment mounts horizontally in rack EmersonNetworkPower com EnergySystems North America While every precaution has been taken to ensure accuracy and completeness herein Emerson Electric Co assumes no responsibility and disclaims all liability for damages resulting from use of this information or for any errors or omissions Specifications subject to change without notice Emerson Network Power Energy Systems North America Inc 2015 Business Critical Continuity Emerson Network Power the Emerson Network Power logo Emerson and Consider it Solved are service marks and trademarks of Emerson Electric Co EnergyMaster eSure NetPerform NetReach NetSpan NetSure and NetXtend are trademarks of Emerson Network Power Energy Systems North America Inc Any other product brand or company names or logos are the property of the respective owner EMERSON CONSIDER IT SOLVED 6 O950RA NS211 0315
7. itional information or questions visit or call Web www EmersonEnergy com E Tel 1 800 800 1280 USA and Canada O950RA NS211 0315 Netsure 211 Ordering Guide 48 VDC Power Solutions Mini System EMERSON Network Power Configuration 1 continued Catalog Number Part Number Quantity Description Step 1g Select Battery Cables if Required 58213660071 8 AWG battery cable for 1 battery string 58213660072 10 AWG battery cable for 2 battery strings Step 1h Select Battery Cabinet if Required 554631 Wall or rack mounted battery cabinet holds 4 40 Amp hour M12V40F batteries Step 1i Select Battery Tray if Required 582136700SK001 19 battery tray that accepts M12V105FT batteries Kit includes tray battery disconnect box 100 A disconnect 582136700SK002 23 battery tray that accepts M12V155FT and M12V180FT batteries Kit includes tray battery disconnect box 100 A disconnect Step 1j Select Wall Mounting Kit if Required 541285 Wall mount kit allows the power system to mount to wall Can be mounted vertically or horizontally and includes mounting hardware 552537 19 wall mount kit provides 6 RU of mounting space equipment mounts horizontally in rack 552535 23 wall mount kit provides 6 RU of mounting space equipment mounts horizontally in rack For additional information or questions visit or call Web www EmersonEnergy com Tel 1 800 800 1280 USA
8. of 1 000 watt rectifiers needed at 1 20 VAC input 1 of 1000 watt rectifiers needed at 240 VAC input 1 OIOIOIOIOIOIOIOIOIOIOIOIOIOIOIOIOIO O Note 1 Rectifier quantity includes one redundant unit for each Note 2 Power levels used for calculation are based on minimum available power per unit at minimum operating voltage 42 VDC at ambient of 45 C Note 3 Battery parameters used in this chart are from Exide Other vendor batteries may have different parameters Table B Select a System Based on the Number of Rectifiers amp Distribution Type Required Shelf Size Number of Rectifiers Distribution Configuration 1 19 x 1 RU Up to 2 rectifiers 10 GMT fuse positions Configuration 1 23 x 1 RU Up to 3 rectifiers 10 GMT fuse positions i n m Up to 4 load breakers or Configuration 2 19 x 2 RU Up to 4 rectifiers Up to 17 GMT fuses Configuration 2 23 x2RU Up to 6 rectifiers Up to 4 load breakers or Up to 17 GMT fuses Note Click the system name to jump to that section For additional information or questions visit or call Web www EmersonEnergy com E Tel 1 800 800 1280 USA and Canada 2 095ORA NS211 0315 Netsure 211 Ordering Guide 48 VDC Power Solutions Mini System Configuration 1 NetSure 211 1 NetSure 211 19 Shelf 1 RU RU Up to 40 A N 1 N EMERSON Network Power Catalog Number Part Number Quantity Description
9. ure 211 19 Shelf 1 RU Requester Contact Information Name Company Title Email Phone These are required fields Please complete before submitting the form For additional information or questions visit or call Web www EmersonEnergy com E Tel 1 800 800 1280 USA and Canada O950RA NS211 0315 EMERSON Network Power NN N N EMERSON Netsure 211 Ordering Guide 48 VDC Power Solutions Mini System Ner Notk POE i Ee Table A Calculate the Number of Batteries and Rectifiers Needed Enter the name quantity and power consumption of each power system The chart below will calculate the total power consumption for each type of equipment entered as well as the number of batteries and rectifiers needed for the system Power Power Consump Consump Equipment Name Qty Each Watts Total Watts 48 VDC of 40 A Hr strings for 4 hour backup 48 VDC of 40 A Hr strings for 8 hour backup 48 VDC of 105 A Hr strings for 4 hour backup 48 VDC of 105 A Hr strings for 8 hour backup 48 VDC of 155 A Hr strings for 4 hour backup 48 VDC of 155 A Hr strings for 8 hour backup 48 VDC of 180 A Hr strings for 4 hour backup 48 VDC of 180 A Hr strings for 8 hour backup CO O O O O O IOO of 500 watt rectifiers needed at 1 20 VAC input of 500 watt rectifiers needed at 240 VAC input 1 a