Home

Emerson GXT4 Brochures and Data Sheets

image

Contents

1. EmersonNetworkPower com While every precaution has been taken to ensure accuracy and completeness in this literature Liebert Corporation assumes no responsibility and disclaims all liability for damages resulting from use of this information or for any errors or omissions 2015 Liebert Corporation All rights reserved throughout the world Specifications subject to change without notice All names referred to are trademarks or registered trademarks of their respective owners Liebert is a registered trademark of the Liebert Corporation Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co 2015 Emerson Electric Co SL 23196 R02 15 Printed in USA EMERSON CONSIDER IT SOLVED
2. Design for hardwired input and output connections An optional The UPS has a dual inverter design capable of providing 5 output hardwire version that includes a maintenance bypass is voltages of 240 120 208 120 230 115 220 110 or 200 100 also available and an output power factor of 0 9 The 6U size is the smallest for When the ease of plug and play power connections is 208 120 selectable voltage in the 8 10kVA model range desired optional versions of the power distribution box The unit features integrated internal automatic and manual convert Liebert GXT4 UPS 5 and 6kVA units to a cord type maintenance bypass power module battery modules and input with receptacles for output distribution and also optional plug and play distribution plates offers maintenance bypass capability that allows hot swapping of the entire UPS without interruption of power to the connected load The standard 8 and 10kVA models include terminal blocks for hardwired connections of both input and output Optional power distribution modules PODs are available to add output The UPS has as adaptable dual inverter design capable of receptacles to the rear panel of the unit providing output voltages of 240 120 208 120 230 115 S ble O 220 110 or 200 100 and an output power factor of 0 8 Hot Swappable Operation Liebert GXT4 UPS 8 and 10kVA units feature three bays for one power module and two battery modules The chassis contains a bypass switch that allows a
3. L L N G L6 30P Plug on PD L630 power distribution box 150VAC z 120 208VAC 120 degrees 208 120VAC nominal 100 110 115 120 VAC 2 1 Minute 10 seconds 1 second At least 5 cycles 32 to 104 0 to 40 5 to 122 15 to 50 Less than 55dBA at 3 2ft 1m rear less than 50dBA at 3 2ft 1m front and sides Up to 10 000 ft 3000m at 77 F 25 C without derating 32 to 104 0 to 40 0 to 95 non condensing UL 1778 cUL Listed FCC Class A IEEE ANSI C62 41 Category A amp B ISTA Procedure 1E YES EN61000 4 5 Model Number Used with UPS Model Dimensions W x D x H Unit in mm Weight Unit Ib kg Battery Parameters Type Kit Quantity x Battery Quantity x V x Rating Recharge Time GXT4 144VBATKIT GXT4 5000RT208 GXT4 6000RT208 GXT4 240VBATKIT GXT4 288VBATKIT GXT4 8000RT208 GXT4 6000RTL630 GXT4 10000RT208 8 1x 19 3x2 8 7 2x 15 4x 4 4 8 1x 19 7 x 5 3 206 x 490 x 70 184 x 390 x 113 207 x 500 x 135 75 8 34 4 45 4 20 6 71 1 32 3 2x6x12Vx9 0 AH Valve regulated non spillable flame retardant lead acid 2x10x 12V x 5 0AH 2x 12x 12V x 9 0 AH 3 hours to 90 capacity after full discharge into 100 load External battery cabinet specifications Model Number GXT4 144VBATT GXT4 240VBATT GXT4 288VBATT GXT4 8000 amp Used w UPS Model GXT4 5000 amp GXT4 6000RT208 GXT4 6000RTL630 GXT4 10000RT208 Dimensions W x D x H 16 9x26 1x3 3 16 9 x 22 6 x 6 8 16 9 x 26 5 x 6 8 Unit w
4. 6 3 6 6 3 6 6 3 4 4 2 6 6 3 Electrical Specifications Amp Rating 63 Amps Input P Ean eres Custom Connector 3W G L L N G to UPS Output Power 2 L6 30R 4 L6 20R 4 5 15 20R T slot 4 2 4 oe 4 L6 20R Connection 8 5 15 20R T slot 4 5 15 20R T slot 4 L6 30R 4 L5 20R 2 L6 20R 2 L5 20R Power distribution box specifications for GXT4 8000RT208 and GXT4 10000RT208 Power Distribution Box Model Number PD2 107 PD2 108 PD2 109 PD2 200 PD2 201 PD2 202 PD2 204 Dimensions W x H Unit in mm 7 4x 5 7 188 x 145 Weight Unit Ib kg 6 6 3 4 4 2 12 5 4 Electrical Specifications Amp Rating 63 Amps Input P tene hd Custom Connector 3W G L L N G to UPS 4 L5 20R Output Power 2 L6 20R 4 lEC320 C19 2 IEC320 C19 2 IEC309 32A Connection 4 5 15 20R 2 L6 30R UOS 4 IEC320 C13 8 5EC320 C13 12EC320CI3 g 1320 13 T slot Emerson Network Power Global Headquarters 1050 Dearborn Drive P O Box 29186 Columbus Ohio 43229 800 877 9222 Phone U S amp Canada Only 614 888 0246 Phone Outside U S Contact EmersonNetworkPower com Emerson Network Power Caribbean and Latin America Office United States of America 1 954 984 3452 Phone Ask Cala Emerson com Emerson Network Power Canada 3580 Laird Rd Unit 1 Mississauga Ontario L5L 577 1905 569 8282 Ask EmersonNetworkPower com liebert com 24 x 7 Tech Support 800 222 5877 Phone 614 841 6755 outside U S
5. Liebert GXT4 UPS 5kVA 10kVA Intelligent Reliable UPS Protection K EMERSON Network Power Today s converged networks require increased availability and reliability IT professionals require higher density power protection systems that adapt to mixed load voltages and plug types while remaining easy to install and maintain The Liebert GXT4 UPS meets the need for higher power capacities in small spaces This true on line double Il conversion UPS system is available v Way in larger capacity models of 5kVA Outages 10kVA and features integrated maintenance bypass as well as optional extended battery runtime Wf Ul Plus Liebert Services provides an optional Power Assurance Package for life cycle support for your UPS including installation start up and on site service The Liebert GXT4 UPS is designed for use in either rack or tower D configurations Spikes 220V 230V and 240V 50 60 Hz models are offered with CE and Ctick markings CN Over Voltage Surges Transient Frequency Under Deviation Voltage Harmonics Output voltages of 240 120 208 120 230 115 220 110 or 200 100 VAC provide the flexibility to adapt to multiple load requirements without the need to add additional transformers that take up extra space and add weight Input power factor correction to 0 99 reduces current harmonics and their heating effects Dynamic ypass Power Factor C
6. esponsibility of handling and documenting the disposal of hazardous materials like batteries POWER ASSURANCE PACKAGE PURCHASED Product Specifications Liebert GXT4 UPS specifications 5 6 8 and 10 kVA models Model Number Model Rating Dimensions Rack Mount W x D x H Unit in mm Weight Unit Ib kg Input AC Parameters Nominal Operating Frequency Factory Default VAC Factory Default L1 N L2 N VAC Input Frequency w o Battery Operation Input Power Connection L1 N L2 N Maximum Allowable VAC Output AC Parameters Factory Default VAC Factory Default L1 N L2 N VAC User Configurable L1 N L2 N VAC Overload Rating 105 to 130 131 to 150 151 to 200 gt 200 impact load Environmental Operating Temp F C Storage Temp F C Audible Noise Operating Elevation Relative Humidity Agency Safety RFI EMI Surge Immunity Transportation ENERGY STAR qualified GXT4 5000RT208 GXT4 6000RT208 GXT4 8000RT208 GXT4 10000RT208 GXT4 6000RTL630 4000W 5000VA 4800W 6000VA 7200W 8000VA 9000W 10000VA 4200W 6000VA 16 9 x 26 1x6 8 16 9 x 26 5 x 10 3 16 9 x 22 6 x 8 5 430 x 662 x 173 430 x 672 x 261 430 x 574x217 131 8 69 9 212 7 96 7 132 2 60 Replacement internal battery part numbers 50 or 60Hz Factory Default is 60Hz 50 or 60Hz Factory Default 60 120 208VAC at 120 degrees 208VAC 120 VAC nominal 40 70 Hz 40 70Hz Hardwire Terminal Block 3W G
7. ith bezel in mm 430 x 662 x 85 430 x 574x173 430 x 672 x 173 Weight Unit Ib kg 99 9 45 3 143 3 65 167 6 76 2 Battery Parameters Type Valve regulated non spillable lead acid Kit Quantity x Battery Quantity x Rating 2x6x 12V x 9 0 AH 2x10x12V x 9 0 AH 2x12x12V x9 0 AH Environmental Operating Temp Storage Temp Operating Elevation and Relative Humidity Same as UPS Power distribution box specifications GXT4 5000RT208 GXT4 6000RT208 and GXT4 6000RTL630 Power Distribution Box PD2 HDWR Model Number MBS PD2 001 PD2 002 PD2 003 PD2 004 PD2 005 PD2 006 PD2 007 PD2 L630 Dimensions W x D xH 4 7x13 2x4 1 Weight Ib kg 8 2 3 7 11 5 10 8 4 9 10 8 4 9 12 1 5 5 12 8 5 8 11 7 5 3 11 7 5 3 8 8 4 Electrical Specifications Amp Rating 30A 2 pole input breaker for UPS input power lout POOL 1 L6 30P ona cannecucns Hardwired L14 30P 10 5 foot 3 2m cord 1 L6 30R 2 L6 20R 2 L6 30R Output Power 1 L14 30R 4 L5 20R 4 L5 20R 2 L6 20R 2 L6 20R Connection Hardwired a 5 s 20R 2 9 19 20R DS DI20R 2 15 30R 2 L6 30R 916208 2 15 20R 2 L6 30R T slot PD2 L630 is only compatible with the GXT4 6000RTL630 UPS model Power distribution box specifications for GXT4 8000RT208 and GXT4 10000RT208 Power Distribution Box Model Number PD2 101 PD2 102 PD2 103 PD2 104 PD2 105 PD2 106 Dimensions W x H Unit in mm 7 4x5 7 188 x 145 Weight Unit Ib kg 4 4 2 6
8. ll modules to be removed without powering down the connected load 5 and 6 kVA Model shown in rack mount position UPS is hardwire input output Optional PODs available with maintenance bypass and includes no POD standard 8 10 kVA Models 6 kVA Model shown in tower orientation Total Care and Support for Critical Systems Power Assurance Package Comprehensive On site Services A Partner To Assure Uptime m Five year protection plan with 100 parts coverage and 7x24 emergency service On site installation and start up Installation and start up of UPS and internal batteries excludes hard wired applications configuration of new UPS and accesories and if purchased safe removal and disposal of old UPS and batteries m On Site service support 7x24 support within 150 miles of regional service center and 100 percent labor and travel coverage m 10076 parts coverage For internal batteries POD Power Output Distribution and web card m 7x24 Access to customer resolution center and on line access to Customer Services Network m Preventative Maintenance in third to fifth year for 5 10kVA models only Key Benefits m Pain free multi site rollout management m Frees up time strapped IT staff by managing and tracking UPS health maintenance and service m Reduces the worry of critical equipment downtime m Ensures rapid recovery in the event of failure within 24 48 hours m Frees you from the r
9. n Software m Liebert Nform Monitoring Software m liebert Universal Monitor And Remote Power Monitor Panels m liebert SiteScan m Jrellis Platform m Third Party Monitoring Systems Liebert IntelliSlot Webcard provides SNMP and web based management 5 and 6kVA Models Offer True On Line Power In A Convenient 8kVA and 10kVA Models Rack Configuration Provide Even More Power Liebert GXT4 UPS 5 and 6kVA models are true on line The Liebert GXT4 UPS 8 and 10kVA units offer a flexible UPS systems that provide internal batteries and dual solution for protecting rack mount equipment including output voltage They are an ideal fit for applications VoIP and PoE where the power requirements are demanding such as Specifically designed for use with the new generation of network closets or small equipment racks high power switches these compact UPS systems pack 8kVA 7 2kW or 10kVA 9kW of power into a 6U rack Adaptable Design tower package with flexible output voltage and optional For installation flexibility the Liebert GXT4 UPS 5 and 6kVA output distribution The UPS includes built in replaceable models allow you to choose from several different wiring batteries for up to 5 8 minutes of runtime at full load configurations made possible by the use of removable depending on model power distribution boxes PODs that simply plug into the rear of the UPS The standard box provides terminal blocks Adaptable
10. orrection Rectifier Charger Battery Ee Surge Utility E Inverter Output Flexibility Rack tower configuration The versatile unit installs in either configuration and includes a rotating color LCD display Automatic frequency detection Detects and matches line input frequencies of either 60 or 50 Hz and can also be programmed to convert from one to the other Replaceable hot swappable internal batteries Provide 5 8 minutes of runtime atfull load depending on the model Additional runtime with additional battery cabinets UPS cabinet includes rear panel plug and play connections for optional battery cabinets Cabinet sizes 5 6 kVA 208 120V 2U 6 kVA 208V and 8 10 kVA 208 120V AU Liebert IntelliSlot communications port Provide SNMP and web based monitoring and control of your UPS Includes Windows based configuration program Allows various operating parameters to be adjusted and tests to be scheduled Built in USB communications for use with Liebert MultiLink Automated Shutdown Software Allows you to monitor communication between the UPS and aserver and ensures a graceful unattended shutdown Built in closure signals Provides notification to monitoring systems of operating conditions Emergency Power Off EPO Terminal connections to integrate into your Emergency Power Off EPO system Higher Availability Wider input voltage window minimizes battery use Features a wide in
11. put voltage window that allows the UPS to support the critical load without having to transfer to battery extending battery life for when itis truly needed Internal automatic and manual bypass Assures continuity of power to critical loads during system maintenance or in case of internal fault Self diagnostics Automatically tests unit electronics and batteries Designed to simplify maintenance and troubleshooting Lowest Total Cost Of Ownership Selectable Eco Mode Connected equipment can be powered through the bypass while the inverter remains at idle reducing electricity consumption Standard two year advanced replacement warranty No hassle warranty provides paid shipping both ways Optional one year and three year extensions available Battery cutoff voltage Automatically adjusts based on load extending battery life by preventing over discharge of batteries ENERGY STAR qualified UPS models UPS products meeting the EPA s requirements use an average of 3525 less energy than their standard counterparts Communications For Power Monitoring And Control Liebert GXT4 UPS offers a variety of communications options to provide the monitoring and control capabilities demanded by today s network computing systems Operation can be monitored using m Liebert IntelliSlot Web Card provides SNMP including SNMPv3 and IPv 6 and web based managementof your UPS m Liebert MultiLink Automated System Shutdow