Emerson FIELDVUEDVC6200p Instruction Manual

image

Contents

1. 4 In the Diagnostics window shown in figure 5 click on Test to check the status of the PROFIBUS card and network Figure 5 Status Network Diagnostics Test s Nodes 01234567839 010111283 41516171819 0 DDT o O III RIR O eE 2 DPI III POCODODPDOPDPPCOProrEtEr O DOU II III III DIDI o DPI III II III DIDI RI RIR OVO III III II RIR RU LA e e WO Key Station passive Read V Station active 7 Station active ready Instruction Manual Supplement DVC6200p Digital Valve Controller D103560X012 November 2014 5 Confirm the status is OK see figure 6 If the status is Failed changes to the parameters set in step 2 may be required Note If the Test fails check the DP PA coupler type used and the parameter setting as recommended by the coupler manufacturer 6 To identify the address of the host and any connected device select Read as shown in figure 6 Figure 6 Status Network Diagnostics simatic NET diagnostics PC Adapter USB A2 PROFIBUS 1 PROFIBUS MPI Network Diagnostics Hardware DP RAM Status Network Diagnostics TEST STATUS Bus Nodes 0123456789 0425450610810 O DPI II DIDI II DI e 20 DD DIO AO O A RIR IR IR IRIS o COBDOOD 60 i E E nn dO a a E A A wi o a a DIO WOOD Key Station passive READ Read M Station active 7 Station active ready OK Cancel Help 7 Any master or slave devices that is
2. EB sanbox 3 Process Device Network View C Program Files x86 SIEMENS STEP7 S7Proj sanb OX gt EEB sanbox 3 a USMTNG FLOW17 E PROFIL DO 222 E networks Open Object Ctrl Alt 0 Cut Ctrl X Copy Ctrl C Paste Ctrl V Delete Del Insert New Object Object SIMATIC PDM b Rename F2 Object Properties Alt Return Instruction Manual Supplement DVC6200p Digital Valve Controller D103560X012 November 2014 6 Enter the Object name for example the tag name and define the PROFIBUS address Click on Assign Device Type Select PA Standalone for standalone station PDM or PA Step7 when PDM is in an integrated environment Click OK Click OK in the resulting screen Note The default address of the DVC6200p is set by the factory to 126 This may need to be changed depending on plant requirements Figure 15 Defining the PROFIBUS Address DEFINES THE EXPECTED PROJECT ADDRESS RR Insert Object PROFIBUS DP network Object name PA Standalone 2 Assign Device Type PROFIBUS address Count Catalog path DEVICE PROFIBUS_PA ACTUATOR ELECTRO_PNEUMATIC FISHER_CONTROLS FISHER_CONTROL DVC6200P_PDM License information 0 of a maximum of 4 TAGs used Lok cma Insert Object Assign Device Type Device Type DE Devices J PROFIBUS DP BY PROFIBUS PA MY Actuators gt MY Electropneumatic MY Fisher Controls PB DVC6200p i E PA Standalone DE PA Ste
3. the shortcut in the Windows desktop or from the Windows Start Up Menu Select File gt New as shown in figure 10 to create the new project Enter the project name or open an existing user project and select OK The project is saved to the SIEMENS program files by default as shown below however you can define the path if a project file is already established Figure 10 Create New Project ot om 48 SIMATIC PDM stand alone User projects Window View Options Help CtrleN B02 Scratch C Program Files x96 SIEMENS STEPFis proj 2_Scr Open Ctrl O Delete PROJECT NAME Reorganize Manage Archive Retrieve Page Setup PCY _401_87654321 Project 1 02 Scratch Project Ci SIEMENS STEP s7 proj 02_Scrat Exit Alt F4 Storage location path C NProaram Files BENRSIEMENSASTEP ef pro Browse DEFAULT Cancel Help STORAGE LOCATION DVC6200p Digital Valve Controller Instruction Manual Supplement November 2014 D103560X012 2 Right click on the project in the left hand pane select Insert New Object gt networks if not already available Figure 11 Adding Networks ET e Fa E Ctrl x Ctrl C PRO ECT Ctrl V NAME Del Insert New Object Rename Object Properties Alt Return File Edit Insert Window View Opti Ip Dae be f EE a lt No Filter gt J47 BEM EEE PCV 401 87654321 3 Right click on the networks ic
4. 012 for DVC6200p Scanordlick installation connection and initial configuration information If a copy of this quick fo dccoss start guide is needed scan or click the QR code at the right contact your Emerson field support Process Management sales office or visit our website at www Fisher com 3 FISHER y www Fisher com Instruction Manual Supplement DVC6200p Digital Valve Controller D103560X012 November 2014 Related Documents e Fisher FIELDVUE DVC6200 Series Digital Valve Controller quick start quide D103556X012 e Fisher FIELDVUE DVC6200p Digital Valve Controller instruction manual pending All documents are available from your Emerson Process Management sales office Also visit our website at www FIELDVUE com Instruction Manual Supplement DVC6200p Digital Valve Controller D103560X012 November 2014 Connecting the DVC6200p using Enhanced Device Description EDD for Siemens SIMATIC PDM Refer to figure 1 Figure 1 Connecting the FIELDVUE DVC6200p using EDD for Siemens SIMATIC PDM PROFIBUS PA POWER SUPPLY DP PA COUPLER BACK RAIL 24 VDC SUPPLY VOLTAGE FOR DP PA COUPLER sesta 230V 120V AC P DP 9 PIN DP CABLE PURPLE CABLE CONNECTORS PROFIBUS DP MASTER SYSTEM CLASS 2 MASTER PROFIBUS USB PROFIBUS CARD INTERFACE ADAPTER OR PCMCIA TYPE ADAPTER DVC6200p Digital Valve Controller Instruction Manual Supplement November 2014 D103560X012 Setting PG PC Interface Note Setti
5. Assign address and TAG Ec Value comparison E Object Properties Calibration log Change Log 5 Logbook Block Alam Transducer Alert Setup 15M F Online Online Overview Transter DVC6200p Digital Valve Controller Instruction Manual Supplement November 2014 D103560X012 Refer to figure 19 to view the Overview screen interface Overview shows the Primary Purpose Variables and the Device Status and Mode It also allows you to enter the Device Serial Number and access Device Information Stroke Valve and Calibration procedures Figure 19 FIELDVUE DVC6200 EDD Overview DEVICE STATUS CLICK TO SEE ACTIVE STATUS ALERTS CHANGE MODE HERE Y eats Overview Online Overview Status L w Change Primary Purpose Variables Travel Setpoint 125 00 10 Pressure Supply Travel Target 125 00 10 Pressure A Travel 100 39 11 Pressure B Self Calibration Status Successful 11 Drive Signal Value Simulation 11 SIMATIC PDM Change Mode Es Shortcuts WARNING Valve may move if Instrument Mode is changed to In Service Transducer Block Mode to AUTO Enter Serial Number Device Information Stroke Valve Calibrate o In Servic Device Serial Number 21242363 t eas SA E Out of Service Cancel Cos 2 To configure the DVC6200p select Configure gt Guided Setup and go to Device Setup as shown in figure 20 Follow the prompts to con
6. Instruction Manual Supplement DVC6200p Digital Valve Controller D103560X012 November 2014 Fisher FIELDVUE DVC6200p Digital Valve Controller Device Setup and Accessing Communication and Calibration using Siemens SIMATIC Manager PDM Contents Related Documents 00 cece eee eee eee 2 Connecting the Digital Valve Controller using Enhanced Device Description EDD for Siemens SIMAHC PODM sensprera nana ra todoo 3 Setting PG PC Interface oooooomo o 4 Loading the DVC6200p EDD to the SIMATIC Manager PDM Catalog 8 Device Setup using Siemens PDM Software 11 Going Online with the DVC6200p 17 Performing One Step Local Quick Setup to Calibrate and Tune the DVC6200p 19 This document takes you through setting up and accessing the DVC6200p using Siemens SIMATIC PDM software as well as performing initial actuator and valve configuration calibration and tuning using the Guided Setup procedure The procedures covered in this supplement were completed using Siemens SIMATIC Manager PDM 8 1 While the steps taken should remain basically the same screens may vary slightly if you are using a different version of the software Ensure that all necessary files including the latest DVC6200p EDD are available Note Setting PG PC Interface and loading the DVC6200p EDD are generally required only once per computer Refer to the DVC6200 Series Quick Start Guide D103556X
7. connected will be reflected in the example shown in figure 7 the PROFIBUS card is connected to address 4 Station Active refers to Masters on the bus Station Passive refers to the slave devices on the bus An active ready PLC Master Class 1 will be denoted as Station Active Ready Instruction Manual Supplement DVC6200p Digital Valve Controller D103560X012 November 2014 Figure 7 Status Network Diagnostics Station Address SIMATIC NET diagnostics PC Adapter USB A2 PROFIBUS 1 PROFIBUS MPI Network Diagnostics Hardware DP RAM Status Network Diagnostics Test pe Station address 4 STATION ADDRESS Bus parameters Bus Nodes 012345 67 8 9 10111213 1415 16 1718 19 o 00 cn a e a nl nn o a nd e MAE st EM 0 Ma ou me mm om mo BD e o A O BUS NODE 55 SUNS WU MUDO Key Station passive Read Y Station active V Station active ready Note The default address of the DVC6200p is set by the factory to 126 Note In the above example a slave device was found at Bus Node 55 and the Class 2 Master device is at address 4 Make note of the addresses found during the bus node scan for future reference Note It is not necessary to make any changes to information found in the other tabs 8 Select OK to close the Set PG PC interface Loading the DVC6200p EDD to the SIMATIC Manager PDM Catalog Open the Device Integration Manager Siemens Load the EDD file from a source direc
8. figure actuator and valve information calibrate and tune the valve assembly If Device Setup is being done prior to mounting the device refer to the note on the following page Figure 20 Accessing Device Setup GUIDED SETUP Ud Guided Setup Online Guided Setup Initial Setup Device Setup Device Setup is used to configure actuator and valve information calibrate the valve assembly and assign the tuning set for the valve assembly 18 Instruction Manual Supplement DVC6200p Digital Valve Controller D103560X012 November 2014 Note Auto calibration and tuning are part of the Device Setup procedure However if the DVC6200p is not physically connected to an actuator valve assembly you will not be able to perform the auto calibration tuning procedures If Device Setup is being done prior to mounting the device complete Device Setup up to auto calibration and select Cancel as shown in figure 21 Once the DVC6200p is mounted to the actuator valve assembly calibration and tuning can be performed using the One Step Local Quick Setup to Calibrate and Tune procedure below Figure 21 Select Calibration Type gt Cancel Select Calibration Type Autocalibrate Standard Autocalibrate Extended Help Cancel Performing One Step Local Quick Setup to Calibrate and Tune the DVC6200p Digital Valve Controller Note This calibration method can be used when there is no Class 2 master ex SIMATIC PDM or other configuration s
9. g screen Note The device must be uploaded to the database using the Upload icon only do not upload from the drop down menu Figure 17 Upload Device to Database C PCV 401 Siemens L File Device View Diagnostics Help BS ee OR e OFFLINE ee Parameter Vie Offline E cp UPLOAD Offine 4 Physical Block E Security Transducer Block Acyclic Write Refused Analog Input Protection 8 Losa to pepe peva RA Analog Output Discrete Input 1 Physical Bl sejecion Discrete Input2 Elinformatil o Cta Discrete Output Tag Desc a Logbook Block 2 ld bend te PRPC A 5 Alarm Transducer User Info Alert Setup Descriptor Talechon 5 2 18M Device Mk Viga Device Ins 55 Oe Ident Num Revision Software Hardware TAG NAME Identifies Saba Mans Sat o i Lied lo POPC Massas a erica were eed la START UPLOAD Maruna fiat Rs Cem UPLOAD COMPLETE The project is now setup and you are able to communicate with the DVC6200p Proceed to Going Online with the DVC6200p on the next page 16 Instruction Manual Supplement D103560X012 Going Online with the DVC6200p DVC6200p Digital Valve Controller November 2014 1 Click on Device gt Online to access to open the DVC6200p EDD as shown in figure 18 Figure 18 Going Online View Diagnostics Help Download to device 2 Upload to PG PE Par
10. is only needed once unless a new or updated EDD is required Figure 9 EDD Loaded on Device Integration Manager r A Device Integration Manager Siemens eer Casos SIMATIC PDM SP1 Process Device Manager o nExese5 AADA Source folder lic D DVC6200p_0103_B1R_EDD zip Filter1 X Filter2 X Filter3 X St Path Device name Manufacturer Communication Type M 7 Devices a SE PROFIBUS PA e Actuators a Electropneumatic ED lg Fisher Controls O DVC6200p DVC6200p Fisher Controls PROFIBUS_PA ACTUATOR EL DD Rev 3 Build Date Lc EDD LOADED TO CATALOG 4 m t Reading process is terminated Read device descriptions 2 Instruction Manual Supplement DVC6200p Digital Valve Controller D103560X012 November 2014 Device Setup using Siemens SIMATIC PDM Software Before beginning Device Setup be sure the instrument is correctly mounted and all pneumatic and electrical connections are made Refer to the quick start guide for general mounting guidelines or the installation instructions supplied with the mounting kit Pneumatic and electrical connection information can also be found in the the quick start guide A WARNING Changes to the instrument setup may cause changes in the output pressure or valve travel Depending on the application these changes may upset process control which may result in personal injury or property damage 1 Launch the SIMATIC Manager application through
11. ng the PG PC interface or PC card CP 5711 or similar PROFIBUS card is done only once after the first hardware installation of the PC card inside the computer 1 Set PG PC Interface is available under the PC Control Panel once Siemens STEP 7 or SIMATIC Manager PDM software is installed a Goto Set PG PC Interface as shown in figure 2 b Under the Interface click on Select to add the PCI PCMCIA USB type PROFIBUS card installed on the PC c Once the interface or card appears as shown in figure 2 select the interface adapter installed and click on Properties In this example the PC Adapter USB A2 PROFIBUS 1 lt Active gt is selected For further support on Setting PG PC Interface visit the following Siemens website for detailed setup procedures http support automation siemens com WW view en 25471997 Figure 2 Set PG PC Interface Access Path LLDP DCP PNIO Adapter Access Point of the Application S7ONLINE STEP 7 gt PC Adapter USB A2 PROFIBUS 1 Standard for STEP 7 Interface Parameter Assignment Used PC Adapter USB A2 PROFIBUS 1 lt Active Properties PC Adapter USB A2 FWL 1 a Diagnostics PC Adapter USB AZ FPWL FAST l HE PC Adapter USB AZ MPL 3 Copy SELECT THE PC Adapter USB 42 PROFIBUS 1 PROFIBUS E TT t INTERFACE ADAPTER Parameter assignment of your PC Adapter USB A fora PROFIBUS network Interfaces Add Remove Instruction Manual Supplement DVC6200p Digital Valve Co
12. ntroller D103560X012 November 2014 2 If the PROFIBUS card is the only master on the bus select PG PC is the only master on the bus as shown in figure 3 If there are other Class 1 or Class 2 masters on the bus then DO NOT select PG PC is the only master on the bus Under Network Parameters select the appropriate Transmission Rate of the bus Click OK when all parameters are set Figure 3 PROFIBUS Card Parameter Setting PROFIBUS PARAMETER SETTINGS Station Parameters Timeout Network Parameters Transmission Rate 45 dE kbps Highest Station Address 126 Profile DP Standard User defined Bus Parameters Standard Cancel Help Note The parameter setting above applies only if the PG PC card is the only master on the bus DVC6200p Digital Valve Controller Instruction Manual Supplement November 2014 D103560X012 3 Click on Diagnostics as shown in figure 4 Figure 4 Diagnostics Access Path LLDP DCP PNIO Adapter Access Point of the Application S7ONLINE STEP Y gt PC Adapter USB A2 PROFIBUS 1 Standard for STEP 7 Interface Parameter Assignment Used PC Adapter USB AZ PROFIBUS 1 Active Properties ER PC Adapter USB A2 FWL 1 gt PC Adapter USB AZ PWL FAST Ui EEB PC Adapter USB A2 MPI 1 E EEB PC Adapter USB A2 PROFIBUS 1 4 i j Delete Parameter assignment of your PC Adapter USB A for a PROFIBUS network Interfaces Add Remove
13. ny product Responsibility for proper selection use and maintenance of any product remains solely with the purchaser and end user FIELDVUE and Fisher are marks owned by one of the companies in the Emerson Process Management business unit of Emerson Electric Co Emerson Process Management Emerson and the Emerson logo are trademarks and service marks of Emerson Electric Co All other marks are the property of their respective owners The contents of this publication are presented for informational purposes only and while every effort has been made to ensure their accuracy they are not to be construed as warranties or guarantees express or implied regarding the products or services described herein or their use or applicability All sales are governed by our terms and conditions which are available upon request We reserve the right to modify or improve the designs or specifications of such products at any time without notice Emerson Process Management Marshalltown lowa 50158 USA Sorocaba 18087 Brazil Chatham Kent ME4 4QZ UK A Dubai United Arab Emirates S Singapore 128461 Singapore www Fishercom O O EMERSON Fala E Ja 1 A H r F ko IN J la E Ma 1 L 2011 2014 Fisher Controls International LLC All rights reserved
14. oftware available A WARNING Changes to the instrument setup may cause changes in the output pressure or valve travel Depending on the application these changes may upset process control which may result in personal injury or property damage A WARNING During calibration the valve will move full stroke To avoid personal injury and property damage caused by the release of process fluid or pressure isolate the valve from the process and equalize pressure on both sides of the valve or bleed off the process fluid 19 DVC6200p Digital Valve Controller Instruction Manual Supplement November 2014 D103560X012 Travel calibration and auto tuning can be accomplished by shorting the auxiliary terminal connections shown in figure 22 between 3 to 10 seconds You can abort the procedure by shorting the auxiliary terminals for 1 second Pressure range will also be captured during this procedure Figure 22 Short the Auxiliary Terminal Connections 9 E q essa LOOP NS Note If the digital valve controller is connected with SIMATIC PDM the overview screen of the EDD will indicate calibration in process Note Calibration time varies depending on the type and size of the actuator For a Fisher 667 size 30 actuator typical calibration time is approximately 4 5 minutes Neither Emerson Emerson Process Management nor any of their affiliated entities assumes responsibility for the selection use or maintenance of a
15. on in the right pane and select Insert New Object gt Communications Network as shown in figure 12 Figure 12 Adding Communications Network File Edit Insert Window View Options Help Doe Be e f 5 Bs lt No Fiter gt J aame 4 9 PCV 401 87654321 ni oe Open Object Ctrl Alt O Cut Ctrl X Copy Ctrl C Ctrl V Paste Delete Del Insert New Object Communication network F2 Alt Return Rename Object Properties Instruction Manual Supplement DVC6200p Digital Valve Controller D103560X012 November 2014 4 Enter the Object name then click on Assign Device Type as shown below Navigate to PROFIBUS DP network and select OK Figure 13 Assign Device Type Insert Object networks Object name PROFIBUS DP network 9 Count il 1 Catalog path NET PROFIBUS DP profibus dp edd net profibus dp component License information 0 of a maximum of 4 TAGs used Insert Object Assid Device Type Gi Networks ETHERNET EE HART IE HART Server JE MODBUS IE PROFIBUS DP DB PROFIBUS DP networks fil DP network 4 DB PROFINET Description Order Number 13 DVC6200p Digital Valve Controller Instruction Manual Supplement November 2014 D103560X012 5 Anew network now appears on the right pane as shown in figure 14 Right click on the network and select Insert New Object gt Object Figure 14 Insert Object
16. p7 Integrated Description Fisher Controls Actuator PA Device Description for PDM V6 0 V6 1 V8 0 V8 1 Standalone Version Order Number Status IMPORTANT THIS DEFINES THE DESIRED DEVICE ADDRESS IT MUST MATCH THE EXPECTED PROJECT ADDRESS INDICATED ABOVE Device identification zama e Assign Device Type Insert Object PROFIBUS DP network Object name PA Standalone PROFIBUS address 124 Count 1 Catalog path DEVICE PROFIBUS_PA ACTUATOR ELECTRO_PNEUMATIC FISHER_CONTROLS FISHER_CONTROL DVC6200P_PDM License information 0 of a maximum of 4 TAGs used LJ Comes 15 DVC6200p Digital Valve Controller Instruction Manual Supplement November 2014 D103560X012 7 Right click on the device in the right pane and select Open Object as shown in figure 16 Figure 16 Open Device in SIMATIC PDM Ep sanbox 3 Process Device Network View C Program Files 86 SIEMENS STEP S Proj sanbox_3 E S sanbox_3 PA Store NOS pen Object trl Alt EE networks pam Ob AO DB USMTNG FLOWA Cut Ctrl x PROFIBUS DP net oe a z Paste Ctrl V H D PA Standalone E sido Delete Del SIMATIC PDM b Rename F2 Object Properties Alt Return 8 In the resulting Offline menu screen shown in figure 17 select the Upload icon as indicated below to upload the device to the database Click Start The upload is complete when the tag name appears Close the Upload PG PC dialo
17. tory or from a compressed source as shown in figure 8 Navigate to the EDD file highlight and select Open to add the EDD to the catalog see figure 9 Instruction Manual Supplement DVC6200p Digital Valve Controller D103560X012 November 2014 Figure 8 Loading the EDD File 44 Device Integration Manager Siemens 1 n l n B 7 SIMATIC PDM SP1 Process Device Manager SOURCE DIRECTORY File 5216 1018 x 5405 44 D08 0 View Catalog OR ource folder h COMPRESSED Read device descriptions from compressed SOUrCE q x Fitter y SOURCE Se AA gt E St Path Device name Manufacturer Communication Type New version Integrated version NAVIAGATE TO EDD FILE 4A Open e pos OLE Computer KINGSTON D Organize y New folder bs NY ne Date modified Type Fr Favorites aj BE Desktop DVC6200p_0103_B1R_EDD 4 7 20141 15PM Compressed zipp 1 156 KB de Downloads Recent Places a Libraries Es Documents a Music Pictures Es Videos E Computer amp Local Disk C ee KINGSTON D GA rlosbo USMT 8 sitedata usstlp 3 Los SiteExe Usstlor Filename DVC6200p 0103 BIR EDD v Compressed files zip v 10 DVC6200p Digital Valve Controller Instruction Manual Supplement November 2014 D103560X012 Note Loading the EDD for a specific device such as the DVC6200p on the SIMATIC PDM on a station