Home
Emerson ACE95Jr Data Sheet
Contents
1. 8 1 206 10 1 256 1 25 without Filter 7 5 190 9 8 249 9 4 238 with Filter 11 8 300 10 2 259 10 0 254 B 1 2 15 without Check valve 1 0 25 2 9 74 with Check valve 3 8 96 5 7 145 1 25 without Check valve 4 7 119 3 0 76 2 8 71 with Check valve 7 5 190 5 8 147 5 6 142 8 6 218 A INLET INLET B 8 2 208 11 8 300 8 5 216 1 6 40 11 5 292 SENSING CONNECTION 1 2 NPT 12 5 318 2 5 64 INCHES mm OUTLET PURGES XP SWITCH CONTROL PRESSURE Table 5 Type ACE95jr Dimensions Bulletin 74 1 ACE95JR 7 Ordering Guide Body Size and Connection Styles Select One 1 2 NPT 1 x 1 2 NPT 1 NPT NPS 1 2 DN 15 CL150 RF NPS 1 DN 25 CL150 RF NPS 1 x 1 2 DN 25 x 15 CL150 RF NPS 1 DN 25 Sanitary Flange Actuator Diaphragm Select One Carbon Steel with PTFE Diaphragm Stainless Steel with PTFE Diaphragm Elastomers Select One Nitrile NBR Fluorocarbon FKM Ethylenepropylene EPDM FDA Perfluoroelastomer FFKM Main Valve Coefficient Select One Cv 0 2 Cv 0 4 Control Pressure Range Select One 5 to 0 5 inches w c 12 to 1 mbar 1 to 1 inch w c 2 to 2 mbar 0 5 to 5 inches w c 1 to 12 mbar 4 to 10 inches w c 10 to 25 mbar 8 to 15 inches w c 20 to 37 mbar 0 5 to 1 5 psig 0 03 to 0 10 bar Acce
2. mbar inches mm inches mm 5 to 0 5 12 to 1 GC220701X22 Stainless Steel 2 75 0 88 69 8 22 4 1 0 080 0 085 2 03 2 16 1 1 to 1 2 to 2 GC220701X22 Stainless Steel 2 75 1 60 69 8 40 6 1 0 080 0 065 2 03 1 65 1 0 5 to 5 4 to 10 8 to 15 0 5 to 1 5 psig 1 to 12 10 to 25 20 to 37 34 to 103 GC220701X22 GC220702X22 GC220703X22 GC220708X22 Stainless Steel Stainless Steel Stainless Steel Stainless Steel 2 75 2 00 2 00 2 75 69 8 50 8 50 8 69 8 0 080 0 112 0 125 0 225 2 03 2 84 3 17 5 71 1 The second spring is located under the diaphragm assembly Features and Benefits Large PTFE Diaphragm Resistant to corrosion and highly sensitive to changes in tank pressure Fully Balanced Eliminates setpoint changes caused by variations in inlet pressure Large Actuator Large actuator diaphragm increases sensitivity to tank pressure changes Rolling Diaphragm The rolling diaphragm balances the pilot valve and eliminates friction resulting in extremely accurate control Options and Accessories Inlet Pressure Gauge Displays pressure of blanketing gas supply to the tank blanketing valve Control Pressure Gauge Low pressure gauge to measure control pressure tank pressure Purge Meter Rotameter Maintains a small amount of flow through the sensing or main line Prevents corrosive tank vapors from damaging upstream equipment Pressure Switch Allows in
3. Bulletin 74 1 ACE95JR April 2012 D102722X012 www fisherregulators com Type ACE95jr Tank Blanketing Valve Introduction Tank blanketing is the process of using a gas usually an inert gas such as nitrogen to maintain a slightly positive pressure in an enclosed storage tank Tank blanketing prevents a stored product from vaporizing into the atmosphere reduces product combustibility and prevents oxidation or contamination of the product by reducing its exposure to air Tank blanketing is utilized with various products including adhesives pharmaceuticals pesticides fertilizers fuels inks photographic chemicals and food additives Type ACE95jr valves are self contained fully balanced and used for accurate pressure control on tank blanketing systems These valves help control emissions and provide protection against atmospheric contamination Type ACE95jr valves maintain a positive tank pressure which reduces the possibility of tank wall collapse during pump out operations and prevents a stored product from vaporizing to atmosphere Fully Balanced Plug Design Reduces Inlet Pressure Sensitivity Stainless Steel Construction Available High Sensitivity Self Contained Bubble Tight Shutoff W8157 Figure 1 Type ACE95jr Tank Blanketing Valve Vacuum Settings Available Features Bulletin 74 1 ACE95JR 2 Specifications Sizes and End Connection Styles 1 2 NPT 1 x 1 2 NPT 1 N
4. Emerson Process Management Tescom Corporation USA Headquarters Elk River Minnesota 55330 2445 USA Tels 1 763 241 3238 1 800 447 1250 Europe Selmsdorf 23923 Germany Tel 49 38823 31 287 Asia Pacific Shanghai 201206 China Tel 86 21 2892 9499 For further information visit www fisherregulators com
5. International LLC a business of Emerson Process Management The contents of this publication are presented for informational purposes only and while every effort has been made to ensure their accuracy they are not to be construed as warranties or guarantees express or implied regarding the products or services described herein or their use or applicability We reserve the right to modify or improve the designs or specifications of such products at any time without notice Emerson Process Management does not assume responsibility for the selection use or maintenance of any product Responsibility for proper selection use and maintenance of any Emerson Process Management product remains solely with the purchaser Industrial Regulators Emerson Process Management Regulator Technologies Inc USA Headquarters McKinney Texas 75069 1872 USA Tel 1 800 558 5853 Outside U S 1 972 548 3574 Asia Pacific Shanghai 201206 China Tel 86 21 2892 9000 Europe Bologna 40013 Italy Tel 39 051 419 0611 Middle East and Africa Dubai United Arab Emirates Tel 971 4811 8100 Natural Gas Technologies Emerson Process Management Regulator Technologies Inc USA Headquarters McKinney Texas 75069 1872 USA Tel 1 800 558 5853 Outside U S 1 972 548 3574 Asia Pacific Singapore 128461 Singapore Tel 65 6770 8337 Europe Bologna 40013 Italy Tel 39 051 419 0611 Chartres 28000 France Tel 33 2 37 33 47 00 TESCOM
6. PT NPS 1 2 DN 15 CL150 RF NPS 1 DN 25 CL150 RF NPS 1 x 1 2 DN 25 x 15 CL150 RF NPS 1 DN 25 Sanitary Flange Maximum Operating Inlet Pressure 1 200 psig 13 8 bar Maximum Emergency Outlet Casing Pressure 1 20 psig 1 4 bar Maximum Operating Control Pressure 1 1 5 psig 0 10 bar Control Pressure Ranges 1 See Table 1 Maximum Differential Pressures Up to 200 psig 13 8 bar Main Valve Flow Characteristic Linear Pressure Registration External Capacities See Table 4 Temperature Capabilities 1 Nitrile NBR 20 to 180 F 29 to 82 C Fluorocarbon FKM 0 to 212 F 18 to 100 C Ethylenepropylene EPDM FDA 20 to 212 F 29 to 100 C Perfluoroelastomer FFKM 20 to 212 F 29 to 100 C Flow Coefficients for Relief Valve Sizing 110 of rated Cv Cv 0 2 use Cv 0 22 Cv 0 4 use Cv 0 44 IEC Sizing Coefficients XT 0 655 FD 0 86 FL 0 89 Construction Materials Body 316 Stainless Steel Trim 304 Stainless Steel and 316 Stainless Steel Elastomers Nitrile NBR Fluorocarbon FKM FDA Ethylenepropylene EPDM or Perfluoroelastomer FFKM Diaphragm Polytetrafluoroethylene PTFE Actuator 316 Stainless Steel or Carbon Steel Approximate Weight with all accessories 30 pounds 14 kg Table 1 Control Pressure Ranges OUTLET CONTROL PRESSURE RANGE SPRING PART NUMBER SPRING MATERIAL SPRING FREE LENGTH SPRING WIRE DIAMETER inches w c
7. city Equation 1 Qthermal SCFH air Vtank x 0 0238 Equation 2 Qthermal SCFH nitrogen Vtank x 0 0238 x 1 015 Equation 3 Qthermal Nm3 h air Vtank x 0 169 Equation 4 Qthermal Nm3 h nitrogen Vtank x 0 169 x 1 015 where For Equations 1 and 2 Vtank tank volume gallons For Equations 3 and 4 Vtank tank volume m3 Depending on the method there can be a significant difference in the calculated required capacity No matter which method is used the tank must be equipped with supplemental venting to protect the tank product and personnel in cases of equipment failure fire exposure or other conditions that could cause the tank pressure or vacuum to exceed operating limits Table 4 Capacities in 0 97 Specific Gravity Nitrogen Capacity Information Capacity tables are based on 0 97 specific gravity nitrogen Nitrogen is the most common blanketing gas Should you use a different gas convert the tabular values as follows For blanketing pad gases other than nitrogen multiply the given nitrogen flow rate by the correction factors in Table 3 For gases of other specific gravities multiply the given nitrogen flow rate by 0 985 and divide by the square root of the appropriate specific gravity Ordering Information Refer to the Specifications section on page 2 Carefully review each specification and construction feature then complete the Ordering Guide Also please complete the Specification
8. d pumped out of the tank Direct displacement does not account for fl uctuating temperature or other factors that may affect pressure in the vapor space This method is typically applied to tanks operating at constant temperatures and containing non fl ammable non volatile products Qtotal Qpump where Qtotal Required Flow Rate Qpump Required Flow Rate to replace pumped out liquid from Table 2 API 2000 The American Petroleum Institute Standard 2000 API 2000 sizing criteria accounts for liquid pump out as well as contraction of tank vapors due to cooling When using API methods Qtotal Qpump Qthermal where Qtotal Required Flow Rate Qpump Required Flow Rate to replace pumped out liquid from Table 2 Qthermal Required Flow Rate due to thermal cooling See Thermal Equations 1 through 4 Bulletin 74 1 ACE95JR 5 Table 2 Flow Rate Conversion 1 MULTIPLY MAXIMUM PUMP RATE OUT BY TO OBTAIN 1 U S GPM U S GPH m3 h 8 021 0 1337 1 01 SCFH SCFH Nm3 h Barrels h Barrels day 5 615 0 2340 SCFH SCFH 1 Gas flow of blanketing gas to replace liquid pumped out Table 3 Correction Factors for converting nitrogen flow rates to other gas flow rates BLANKET GAS SPECIFIC GRAVITY CORRECTION FACTOR Natural Gas 0 60 1 270 Air 1 00 0 985 Dry CO2 1 52 0 797 Correction Factor 0 985 SG Thermal Equations For tanks up to 840 000 gallons 3180 m3 capa
9. ingle tank nozzle Inlet Filter Screens out any foreign material upstream that may cause blockage in the gas flow Principle of Operation The Type ACE95jr tank blanketing valve controls the vapor space pressure over a stored liquid When liquid is pumped out of the tank or vapors in the tank condense the pressure in the tank decreases Tank pressure is sensed by the large actuator diaphragm When tank pressure is less than the valve set pressure spring force moves the actuator diaphragm downward Bulletin 74 1 ACE95JR 4 BLANKETING GAS SUPPLY LINE LINE STRAINER SHUTOFF VALVE SENSING LINE SHUTOFF VALVE SHUTOFF VALVE TYPE 252 INLET FILTER EMERGENCY TANK VENT BLANKETING GAS TO TANK TANK VENT TANK LIQUID BLANKETING GAS VAPOR SPACE TYPE ACE95jr Figure 3 Type ACE95jr Tank Blanketing Valve Installation When installing Type ACE95jr the sensing line and gas to tank line must always be above the tank liquid level and should slope down towards the tank without any traps to avoid catching of liquid Inlet supply line may be installed with a fi lter and the outlet piping should be full sized and self draining to the tank and also valves and vents must be full line size and should be mounted above the tank Sizing Methods Direct Displacement Use the direct displacement method with extreme caution The direct displacement method determines the amount of blanketing gas required to replace liqui
10. s Worksheet at the bottom of the Ordering Guide on page 7 INLET PRESSURE Cv 0 2 SCFH Nm3 h Cv 0 4 SCFH Nm3 h psig bar kg cm2 kPa SCFH Nm3 h SCFH Nm3 h 1 1 2 1 5 1 10 0 07 0 14 0 34 0 69 0 07 0 14 0 35 0 70 6 90 13 8 34 5 69 0 42 61 98 130 1 1 1 6 2 6 4 6 84 120 210 310 2 2 3 2 5 6 8 3 15 20 25 30 1 0 1 4 1 7 2 1 1 06 1 41 1 76 2 11 103 138 172 207 160 210 250 290 4 3 5 6 6 7 7 7 400 480 550 630 10 7 12 9 14 7 16 9 40 50 60 70 2 8 3 4 4 1 4 8 2 81 3 52 4 22 4 92 276 345 414 483 370 450 530 610 9 9 12 1 14 2 16 3 780 930 1070 1230 20 9 24 9 28 7 33 0 80 90 100 120 5 5 6 2 6 9 8 3 5 63 6 33 7 03 8 44 552 621 690 827 690 780 860 1020 18 5 20 9 23 0 27 3 1390 1560 1720 2040 37 3 41 8 46 1 54 7 140 160 180 200 9 6 11 0 12 4 13 8 9 85 11 3 12 7 14 1 965 1103 1241 1379 1180 1340 1500 1660 31 6 35 9 40 2 44 5 2360 2680 3000 3330 63 2 71 8 80 4 89 2 1 Assumes an outlet control pressure of 5 inches w c 12 mbar or less Bulletin 74 1 ACE95JR 6 Figure 4 Type ACE95jr Dimensions BODY SIZE NPS DN STRUCTURE DIMENSIONS NPT CL150 RF Flange Sanitary A NPS DN inches mm inches mm inches mm 1 2 15 without Filter 3 7 94 9 7 246 with Filter
11. ssories Optional Inlet Pressure Gauge Control Pressure Gauge Purge Meter Rotameter Pressure Switch Outlet Check Valve Inlet Filter Single Array Manifold Optional Yes please add a SAM unit to my order Applicable only for 1 2 NPT body size and end connection Parts Kit Optional Yes please send one parts kit to match this order Regulators Quick Order Guide Readily Available for Shipment Allow Additional Time for Shipment Special Order Constructed from Non Stocked Parts Consult Your local Sales Office for Availability Availability of the product being ordered is determined by the component with the longest shipping time for the requested construction Specification Worksheet Application Specifications Product in Tank Tank Size Pump In Rate Pump Out Rate Blanketing Gas Type and Specific Gravity Conservation Vent Setpoints Pressure Vacuum Pressure Requirements Please Designate Units Maximum Inlet Pressure P1max Minimum Inlet Pressure P1min Control Pressure Setting P2 Maximum Flow Qmax Other Specifications Is a vapor recovery regulator required Yes No Other Requirements Bulletin 74 1 ACE95JR Emerson Process Management Regulator Technologies Inc 2001 2012 All Rights Reserved The Emerson logo is a trademark and service mark of Emerson Electric Co All other marks are the property of their prospective owners Fisher is a mark owned by Fisher Controls
12. stallation of an alarm system to indicate low or high pressure on the tank 1 The pressure temperature limits in this Bulletin and any applicable standard or code limitation should not be exceeded Bulletin 74 1 ACE95JR 3 When the actuator moves downward it pushes open the valve plug which allows flow in to the tank See Figure 2 When pressure in the tank increases above setpoint the large actuator diaphragm is pushed upward allowing the valve plug to close The valve plug is balanced inlet pressure creates equal upward and downward force on these components therefore the outlet control pressure of the unit is not affected by fluctuating inlet pressure Installation The Type ACE95jr tank blanketing valve was assembled and preset to the customer specified pressure and setpoint at the factory The outlet control pressure range of the valve is stamped on the nameplate fastened to the upper actuator case The gas blanketing setpoint is the only adjustable feature on this unit INLET PRESSURE TANK PRESSURE ATMOSPHERIC PRESSURE VALVE OPEN VALVE CLOSED SENSING CONECTION ROLLING DIAPHRAGM O RING SEAT CAGE POPPET INLET TO TANK Figure 2 Operational Schematic E0205 Outlet Check Valve Prevents corrosive gases and vapors from flowing back into the blanketing system through the delivery line Single Array Manifold SAM Provides sense line connection and main valve connection through a s
Download Pdf Manuals
Related Search
Related Contents
Ficha de Datos de Seguridad M7040DT - kucenter.mx Recurring Contract Billing Importer Mode d`emploi TDSHーBA 東芝電球埋込ダウンライト取扱説明書 immerSUN Installation and User Guide v1.1 Samsung SDW-T120BH User Manual Installation & Quick Setup Guide - Tri MPL1 _MP3 player APL15_ user manual - V1,0 Copyright © All rights reserved.