Home
        Elkay HCR8*1J User's Manual
         Contents
1. HCR8 1J    Installation Instructions    HCR8 1J Refrigeration Packages    NOTICE  This water cooler must be connected to the water supply using a dielectric coupling   IMPORTANT  INSTALLER PLEASE NOTE     The grounding of electrical equipment such as telephone  computers  etc   to water lines is a common procedure  This ground   ing may be in the building  or may occur away from the building  This grounding can cause electrical feedback into a water  chiller  creating an electrolysis which causes a metallic taste or an increase in the metal content of the water  This condition is  avoidable by using the proper materials indicated below     1  A I INSTALLATION       25mm 1  When mounting unit in an open area  to insure proper ventilation   maintain a 4   102mm  clearance from cabinet louvers on each side  of cooler   When mounting unit in a cavity or behind a wall maintain  minimum space of 4   102mm  on each side  4   102mm  on the top  and a depth of 12   305mm             A 2  Water inlet is 1 4   6 mm  O D  tube  Contractor to supply the  a connections as required   Neil 2  3  Connecting lines to be of unplated copper  thoroughly flushed to    remove all foreign matter before being connected to cooler  If  flushing does not remove all particles  a water strainer should be  installed in supply line  This cooler is manufactured in such a manner  that it does not in any way cause taste  odor  color or sediment              r problems     4  Connect cooler to building supply l
2. WATER OUTLET C   TEMPERATURE ADJUSTMENT   B   1 4  O D  TUBE WATER INLET D   ELECTRICAL    16 3 4   425mm          R OD diea OPERATION OF QUICK CONNECT FITTINGS    1 4  O D  TUBE COPPER TUBE CONNECT  WATER INLET COLD WATER SUPPLY    TO CHILLER   BUILDING WATER INLET SIMPLY PUSH IN TUBE IS SECURED PUSH IN COLLET      TUBE TO ATTACH IN POSITION TO RELEASE TUBE     8  amp  7   L                                                                                                 CL    NOTE  WATER FLOW PUSHING TUBE IN BEFORE  DIRECTION SERVICE STOP PULLING IT OUT HELPS TO   NOT FURNISHED  RELEASE TUBE       HCR8 1J    115V ITEMIZED PARTS LIST                  1 66534C EVAPORATOR TANK ASSY  2 28478C CABINET  3 66743C CONDENSER  4 31490C MOTOR   FAN 115V  5 20282C BRACKET   FAN MOUNTING D SERERE  B  6 30664C BLADE   FAN r2 ru  7 70018C NUT   FAN BLADE  8 56237C SHROUD   FAN  9 66576C HEAT EXCHANGER  66703C DRIER  36094C COMPRESSOR SERVICE PAK o G  31513C COLD CONTROL  28477C PANEL   FRONT         35768C COVER   RELAY  36158C OVERLOAD  35959C RELAY  100806740570   GROMMET      b  101516143550   STUD   COMP  MOUNTING  19037000 CLIP q             50930C BUMPER   27303C BASEPLATE   22300C PANEL   REAR  55996C IN LINE STRAINER  66723C EVAPORATOR TUBE              INCLUDES RELAY  amp  OVERLOAD  IF UNDER WARRANTY   REPLACE WITH SAME COMPRESSOR USED IN ORIGINAL  ASSEMBLY    NOTE  All correspondence pertaining to any of the above water  cooler or orders for repair parts MUST include model number 
3. and  serial number of cooler  name and part number of replacement  part        WIRING DIAGRAM        GND    WHT         ll       BLK          DER  e   IE Su NN RE    jM    COMPRESSOR    COLD CONTROL   WATER                                21    11  14  15  16     98198C  9 05     
4. ine with a shut off valve and  treu B install the in line strainer between the valve and cooler   E 5  Electrical  Make sure power supply is identical in voltage  cycle   atin and phase to that specified on cooler serial plate  Never wire  compressor directly to the power supply   6  This chiller has been designed for use with potable water ONLY   T f START UP  13 4  REF  1  Open supply line valve     2  Purge air from all water lines by operating bubbler valve of  fountain to which cooler is connected  Steady stream assures all  air is removed    3  Rotate fan to insure proper clearance and free fan action    4  Connect to electrical power        TROUBLE SHOOTING  amp  MAINTENANCE    Temperature Control  Factory set at 50  F    5    under normal  conditions  For colder water  adjust screw on item no  12 in  clockwise direction    C Ventilation  Cabinet louvers and condenser fins should be  periodically cleaned with brush  air hose or vacuum cleaner   Excess dirt or poor ventilation can cause no cold water and  compressor cycling on the compressor overload protector    Lubrication  Motors are lifetime lubricated    Actuation of Quick Connect Water Fittings  Cooler is provided  with lead free connectors which utilize an o ring seal  To remove  tubing from the fittings  relieve water pressure  push in on gray  collar while pulling on the tubing  To insert tubing  push tube  straight into fitting until it reaches a positive stop  approximately   LEGEND 3 4     A  1 4  O D  TUBE 
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
Installation manual Anna.  BG-EM 1030  Lowrance electronic HDS-5X Fish Finder User Manual  Manual de Utilização do Tcpdump  GR DIGITAL II Insertion  Instrucciones de uso Balanza compacta PCE-WS  32 SLi • 36 SLi INTENSIVE • 36 SLi • 32 SPr • 36 - NT  Samsung 2233RZ Priručnik za korisnike    Copyright © All rights reserved. 
   Failed to retrieve file