Home

Electrolux AH 360-120 User's Manual

image

Contents

1. Control panel 5 Grease filter key 6 Ventilation level display Z Coanda level key 8 Light control knob 9 Ventilation level control knob 10 Afterrunning key 11 Afterrunning symbol 12 Grease filter saturation symbol 13 Coanda level symbol 14 Intensive level symbol 15 Intensive level key Installation accessories LK 360 010 Ventilation duct for ceiling heights of 2 30 2 66 m LK 360 020 Ventilation duct for ceiling heights of 2 66 3 00 m 2 3 Operating principle This extractor hood swiftly and silently extracts all odours produced while cooking You can set different intensity levels depending on the intensity of odours The fan in the extractor hood sucks in the kitchen vapours and passes them through the grease filter to outdoors The grease filter absorbs the greasy components in the kitchen vapours see Fig 4 The Coanda effect Kitchen vapours are extracted even better with the Coanda effect By means of an additional motor kitchen vapours are passed swiftly and effectively into the hood s extraction zone An additional fan on the front edge of the kitchen extractor hood generates an air stream that is diverted around a cylinder towards the rear This ensures that kitchen vapours are routed completely into the extractor hood s filter area See Fig 5 3 Operation 3 1 Switching on and off Switching on Tum the Ven
2. Extract the protective file from the chimney paneling Note Avoid damaging the sensitive stainless steel surfaces Fit the top of the chimney into the base Make sure that the fastening holes on the side are at the top Secure the top duct unit with 2 screws on the ceiling holder Pull the shoe down into its final position Fig 19 Note Avoid scratches when fitting the elements into one another by placing the assembly template for example over the edge of the bottom chimney paneling to protect it Reinsert the grease filters Place the 3 glass plates on the hood 5750196934 en 08 01 SK 15
3. Repairs must only be carried out by authorised specialists thus ensuring the safety of the appliance Improper tampering will render all warranty claims null and void Lamp replacement Caution Disconnect the power supply before replacing lamps switch off the fuse Caution Lamps may still be hot shortly after use Risk of burns Detach the ring from the lamp cover Note Make sure that the glass will not fall out Fig 13 Pull out the lamp Fig 14 Defective lamps must only be replaced by lamps of the same type 12 V 20 W G4 lampholder Inserting the lamp Insert the lamp in the lampholder Note Do not touch the halogen lamps with your hands Use a cloth and touch the lamp only on its edges Engage the lamp cover Connect the appliance to the mains again ll 6 Assembly instructions 6 1 Technical data Weight 41 kg without ventilation duct Dimensions 1198 x 560 mm Electrical connection Pay attention to the rating plate data The mains connecting cable must at least correspond to the type H 05 VV F G 0 75 The appliance must only be connected by an authorised specialist paying attention to the relevant regulations of the power supply companies and the regional construction regulations He must explain to the user how the appliance can be isolated from the mains whenever required The connector of the connecting cable 1s connec ted to the socket that is located behind the d
4. operated rings at the same time please operate the extractor hood at level 2 or higher This prevents a build up of heat in the appliance Do not place any heavy objects on the appliance this will have a detrimental effect on functioning Do not clean the appliance with a steam cleaning apparatus or with water pressure because this poses a risk of short circuits Isolate the appliance from the mains during every maintenance operation To do this remove the mains plug or actuate the corresponding fuse If the mains plug is not accessible the appliance must be disconnected by means of the domestic installation fuse Repairs must be carried out by authorised specialists thus ensuring electrical safety No warranty claims can be lodged in the event of damage caused by failure to observe these instructions Adequate incoming air must be ensured if a wood coal gas or oil heater or an open hearth is operated in the same room as the one in which the hood is installed Safe operation is possible whenever the partial vacuum in the place where the firing equipment is installed does not exceed 4 Pa 0 04 mbar This can be achieved whenever the air needed for combustion is able to enter through openings that cannot be sealed for example in doors windows incoming exhaust air wall boxes or other technical means Technical modifications reserved 1 2 Operating for the first time Before operating the appliance for the first ti
5. Operating and assembly instructions AH 360 120 Extractor hood GAGGENAU AH 360 120 Preface 1 Important notes 1 1 For your safety 1 2 Operating for the first time 1 3 About use 2 Structure and operating principle 2 1 Structure of the appliance 2 2 Accessories special accessories 2 3 Operating principle 3 Operation 3 1 Switching on and off 3 2 Special functions 4 Cleaning and care 5 Maintenance 6 Assembly instructions 6 1 Technical data 6 2 Installation Page 3 4 Page 3 Page 4 Page 4 Page 5 6 Page 3 Page 3 Page 6 Page 8 Page 7 Page 8 Page 10 Page ll age l2 15 Page 12 Page 12 15 Preface With your new extractor hood working in the kitchen will be even more fun The appliance offers you a number of advantages effective extraction thanks to the so called Coanda effect low operating noise To ensure that you will be able to use this appli ance in all its diversity read through the operating and assembly instructions conscientiously before operating it for the first time The instructions contain important notes on use installation and maintenance of the appliance On the following page you will find important notes on safety and operation These will serve to ensure your personal safety and the lasting value of your appliance You will find notes on Page 4 that you ought to observe before operating the appliance for the first time The chapters
6. entilation level Or Press the intensive level key The intensive level symbol appears on the display The appliance is now operated at the intensive level for a few minutes and then switches off automatically Ending the intensive level prematurely Tum the Ventilation level knob to the O position or turn the Ventilation level knob to any level or press the intensive level key once again After running Switching on Press the Afterrunning key The Afterrunning symbol and ventilation level 2 light up on the display Fig 10 Or Tum the Ventilation level control knob to any level Press the Afterrunning key The Afterrunning symbol and the set ventilation level light up on the display Fig 11 The extractor hood continues running for 10 minutes Switching off Tum the Ventilation level control knob to the 0 position or Press the Afterrunning key 4 Cleaning and care D Note The handles of the grease filters must be visible after installation They can no longer be removed if the handles are in the inner part of the housing Caution Overgreased filter
7. entitled Structure and operating principle and Operation will tell you all the things your extractor hood is capable of doing and how the appliance is operated Tips and hints in the chapter entitled Cleaning and care will make sure that your appliance will stay operable and beautiful for a long time And now we wish you lots of fun with your new extractor hood BE TFA IIx 7 HA LLL LALL LILIT rS a FZ z Z Z Z Z Z Z M L LALALALA AAAA AAA LLLA A AAAA AAAA 1 Important notes 1 1 For your safety Damaged appliances must not be operated Connecting cables must not come into contact with hot cooking surfaces Do not operate the extractor hood without inserted lamps Never operate the appliance without a grease filter Hazardous or explosive substances and vapours must not be extracted The user 1s responsible for expert use and the perfect condition of the appliance Only ever operate the appliance under supervision Fire risk Do not flamb meals under the extractor hood Only ever deep fry under the extractor hood under constant supervision Operation of the extractor hood above a hearth for solid fuels coal or wood etc is only partly pemnitted Gas appliances may only be used under the extractor hood when pots and pans are placed on them When using more than 2 gas
8. g the glass plates Apply commercially available window cleaning agent with a soft moist cloth To facilitate cleaning you can detach the glass plates as follows Detach the grease filters In the extractor hood you will find two openings on the upper side through which you can lift the glass plates singly with a blunt object e g handle of a wooden spoon to detach them with greater ease If they are extremely soiled the glass plates can be cleaned in a dishwasher at a maximum temperature of 55 C Cleaning the aluminium panel Clean the aluminium panel with a soft cloth only Do not use any strong or caustic cleaning agents or brushes and abrasive cleaner to clean it Do not use strongly alkaline cleaning agents such as oven spray because these are aggressive to the aluminium surface Do not use any abrasive sponges either Clean the stainless steel parts of the extractor hood side panel ventilation duct with mild rinsing detergent and apply stainless steel care agent to the metal surfaces using a soft cloth 5 Maintenance First disconnect the appliance from the mains before carrying out any repairs In the event of malfunctions first of all check the household fuses If the power supply is in proper working order but the appliance is nevertheless not functioning then please contact your specialist dealer or your responsible Gaggenau after sales service specify the appliance type see rating plate
9. me please pay attention to the following notes The appliance must be installed and connected by a specialist before it is operated for the first time Conscientiously read through the operating and assembly instructions before operating the appliance for the first time Remove the packaging from the appliance and dispose of it properly Pay attention to the fact that there are accessories in the packaging Keep packaging elements out of the reach of children Thoroughly clean the appliance before using it for the first time see chapter entitled Cleaning and care Before operating the appliance for the first time check that the mains connection is in proper working order 1 3 About use The appliance is intended solely for use in the household and must not be put to any other uses In the event of malfunctions first of all check the household fuses If the problem has nothing to do with the power supply please contact your specialist dealer or your local Gaggenau aftersales Service a structure and operating principle 2 1 Structure of the appliance 10 11 12 Fig 3 13 14 15 2 2 Accessories special accessories You can order the following special accessories Back draught flap RK 040 150 Back draught flap for insertion in the extractor s blow out opening Flexible aluminium pipe AR 040 150 DN 150 up to 3 5 m length with 2 hose clamps 1 Display 2 Glass plates 3 Air duct 4
10. n this reduces the volume flow As standard the blow out opening of the wall hood is in the upward direction To pass exhaust air through the outer wall we recommend the use of our telescopic wall box TM 150 045 150 Note To prevent the ingress of water e g condensate or rain water from an uncovered exhaust air shaft our condensate separator RV 060 150 must be installed in the exhaust air line The condensate separator must still be acciessible after installation Planning note When installing the hood between wall cupboards it is advisable to leave a space of at least 5 cm on both sides of the hood Depending on the ceiling height the following duct units are at your disposal for exhaust air operation LK 360 010 Ventilation duct for a ceiling height of 2 35 to 2 66 m LK 360 020 Ventilation duct for a ceiling height of 2 66 3 00 m The dimensions above refer to a distance of 1 60 m from the floor to the bottom edge of the hood If required special ventilation ducts are available at an extra charge The socket must be place behind the duct cover on the wall 714 1669 Hood height 2 31 3 27 Ceiling height min 650 over electric cooker min over gas cooker 13 Proceed as follows Important Before marking the securing holes make sure that no electricity or water lines or other lines are laid at the drilling points in the wall Important There are two handles o
11. n top of the hood Only carry the hood using these handles Do not lift the hood by the stainless steel side panels or the aluminium front panel From the bottom edge of the hood mark a center line on the wall With the aid of the drilling template mark the min 650 electric positions of the screws on the wall Mark the da contour of the hook in area This will make it ae So easier to hook in the hood Fig 16 N Pay attention to the minimum clearance of 650 mm for electric cookers and 750 mm for gas cookers The bottom edge of the template corresponds to the bottom from edge of the hood UC i N Using the drilling template drill the 6 holes for the hood area I of the drilling template and the two holes for suspending the chimney area II of the drilling template In the top two securing holes for the hood fix the two hooks d with the countersunk screws c Fit the included dowels a in the other drill holes Note Pay attention to any special accessories that you may have to fit Screw on the retaining bracket for the chimney paneling Detach the grease filters Hang the hood on the two hooks Adjust the suspended element with the recessed head screw and align the hood using a spirit level Fig 17 14 Secure the hood to the wall using the 4 screws b Fig 18 Establish the pipe connection Establish the electrical connection
12. nsible for your district whenever you wish to pass the exhaust air into a chimney that is not in operation During the course of planning a chimney sweep must be consulted if a room airdependent hearth is operated in the same room as the one in which a hood is operated in the exhaust air mode Adequate incoming air must be ensured The applicable construction and safety regulations must be observed Adequate incoming air must be ensured if a wood coal gas or oil heater or an open hearth is operated in the same room as the one in which the hood is installed safe operation is possible whenever the partial vacuum in the place where the firing equipment is installed does not exceed 4 Pa 0 04 mbar This can be achieved whenever the air needed for combustion is able to enter through openings that cannot be sealed for example in doors windows incoming exhaust air wall boxes or other technical means Flexible aluminium pipes corrosion protected sheet metal pipes and exhaust air pipes whose material conforms to fire B1 in accordance with DIN 4102 can be used Exhaust air pipes should have a nominal diameter of 150 mm Pay particular attention to ensuring that the exhaust air ducts and pipes are kept as short as possible the pipes are not laid at an acute angle but as bends and that they are inserted into the shaft at an inclined upward angle and there are no cross sectional constrictions in the upward directio
13. s are a fire risk Pay attention to cleaning the grease filter on a regular basis Cleaning the grease filters The Grease filter saturation symbol flashes on the display after an operating time of 30 hours Flashing of this symbol signals to you that the grease filters have to be cleaned The grease filters can be cleaned at any time even if the Grease filter saturation symbol does not flash The metal filters can be removed easily for cleaning Proceed as follows Grip the grease filter handles and press the slide towards the rear Pull the grease filter out of its mount in the downward direction Fig 12 Repeat the operation with the other grease filters You can clean the metal grease filters ina dishwasher at a maximum temperature of 65 C Place the grease filters vertically in the dishwasher to ensure that no food remainders will stay on them slight discoloration can occur when cleaning the grease filters in a dishwasher When replacing the grease filters wipe out the inner part of the housing with hot detergent solution Reinsert the grease filters in the hood after cleaning Install them in the reverse order to removal Press the Grease filter key to set the elapsed hours counter to zero the Grease filter symbol stops flashing Do not clean the appliance with a steam cleaning apparatus or with water pressure because this poses a risk of short circuits 10 Cleanin
14. tilation level control knob to the ventilation level you require Fig 6 The set level is displayed After a power failure the extactor will not go on again automatically You can recommence operation by turning a knob or by pressing any key Switching off Tum the Ventilation level control knob to the O position Fig T The set level 0 is displayed for a few seconds Note The light can be switched on and off at any time To do this turn the Light control knob to the Light position Switching on the Coanda level Tum the Ventilation level control knob to the level you require Press the Coanda level Key The level you have set and the Coanda level symbol appear on the display Fig 8 Note You can change to any ventilation level and the Coanda level remains set q1 g e 4 r Switching off the Coanda level Press the Coanda level key or turn the Ventilation level knob to the O position 3 2 Special functions Intensive level You should select the intensive level when browning and frying in an open pan Switching on Fig 9 Tum the control knob to a ventilation level 1 3 Press the intensive level key The intensive level symbol appears on the display The previously selected ventilation level flashes on the display After a few minutes the appliance switches back automatically to the previously selected v
15. uct cover on the wall If this is not possible it must be possible to isolate all poles of the appliance from the mains by way of the domestic fuse or by means of accessible isolating device with a contact gap of at least 3 mm If the appliance is to be operated only with the window open to ensure adequate incoming air you can use the window switch A switch normally open is fitted on the window On the appliance this switch is connected to the window switch terminal on the main electronics The appliance can now only be operated when the window is open Important The window switch must only be connected by an authorised specialist Note The light function works without restriction AH 360 120 AC 220 230V 330W FD xxxx 50Hz XXXX 410W XXxx Xt 4x20W 12 6 2 Installation The applicable regulations of the energy supply companies and the regional construction regulations must be observed when installing the hood The minimum distance from the worktop to the bottom edge of the wall hood is for electrical appliances 650 mm and for gas appliances 750 mm The wall hood was conceived for the exhaust air mode The exhaust air can be routed into a separate exhaust air shaft or directly into the open through the outside wall It is not allowed to pass the exhaust air into a flue or exhaust air chimney that is in operation or into a shaft that is linked to the heating basement Consult the chimney sweep respo

Download Pdf Manuals

image

Related Search

Related Contents

  日立 お店 g_ 掃除機~    水上オートバイ マーメイドⅠ被引ゴムボート(船名なし)乗客負傷事件  Bell'O WAVS-327 flat panel floorstand  Havis-Shields S-CM-112-IMP-1 User's Manual  Vers un dictionnaire des mots à Charge Culturelle Partagée comme  Mifare Configurable Sector Reader User`s Manual  facultad de idiomas - Repositorio Institucional de la Universidad  取扱説明書 - Psn  