1. ELED Fresnel 100WW Operating Instructions Elation Professional www elationlighting com ELED Fresnel 100WW User Manual Page 10 Elation Professional www elationlighting com ELED Fresnel 100WW User Manual Page 9 ELED Fresnel 100WW 1 Channel Mode Channel Value Function 1 0 255 DIMMER 0 100 ELED Fresnel 100WW 2 Channel Mode Channel Value Function 1 0 255 DIMMER 0 100 2 0 255 STROBING SLOW FAST ELED Fresnel 100WW Cleaning Due to fog residue smoke and dust cleaning the internal and exter nal optical lenses must be carried out periodically to optimize light output 1 Use normal glass cleaner and a soft cloth to wipe down the outside casing 2 Clean the external optics with glass cleaner and a soft cloth every 20 days 3 Always be sure to dry all parts completely before plugging the unit back in Cleaning frequency depends on the environment in which the fixture operates i e smoke fog residue dust dew ELED Fresnel 100WW Trouble Shooting Listed below are a few common problems the user may encounter with solutions Unit not responding to DMX 1 Check that the DMX cables are connected properly and are wired correctly pin 3 is hot on some other DMX devices pin 2 may be hot Also check that all cables are connected to the right connectors it does matter which way the inputs and outputs are connected Unit does not respond to sound 1 Quiet or high
2. Fax 323 832 9142 E mail support elationlighting com Warning To prevent or reduce the risk of electrical shock or fire do not expose this unit to rain or moisture Caution There are no user serviceable parts inside this unit Do not attempt any repairs yourself doing so will void your manufactures war ranty In the unlikely event your unit may require service please contact Elation customer support PLEASE recycle the shipping carton when ever possible Elation Professional 6122 S Eastern Ave Los Angeles CA 90040 www elationlighting com ELED FRESNEL 100WW ELED Fresnel 100WW Safety Precautions Elation Professional www elationlighting com ELED Fresnel 100WW User Manual Page 4 Elation Professional www elationlighting com ELED Fresnel 100WW User Manual Page 3 To reduce the risk of electrical shock or fire do not expose this unit rain or moisture Do not spill water or other liquids into or on to your unit Be sure that the local power outlet match that of the required volt age for your unit Do not attempt to operate this unit if the power cord has been frayed or broken Do not attempt to remove or break off the ground prong from the electrical cord This prong is used to reduce the risk of electrical shock and fire in case of an internal short Disconnect from main power before making any type of connection Do not remove the cover under any conditions There are no user se
3. To optimize the performance of this product please read these operating instructions carefully to familiarize yourself with the basic operations of this unit These instructions contain important safety information regarding the use and maintenance of this unit Please keep this manual with the unit for future reference ELED Fresnel 100WW General Instructions Two Operating Modes DMX Control amp Manual Control DMX 512 protocol 2 DMX Modes 1 Channel Mode amp 2 Channel Mode Dimming 0 100 in both DMX Channel Modes Strobing in 2 Channel Mode Daisy Chain Units Together in DMX Mode The ELED Fresnel 100WW carries a two year limited warranty Please fill out the enclosed warranty card to validate your purchase All returned service items whether under warranty or not must be freight pre paid and accompany a return authorization R A number The R A number must be clearly written on the outside of the return pack age A brief description of the problem as well as the R A number must also be written down on a piece of paper included in the ship ping carton If the unit is under warranty you must provide a copy of your proof of purchase invoice You may obtain a R A number by con tacting our customer support team on our customer support number All packages returned to the service department not displaying a R A number on the outside of the package will be returned to the shipper Elation Professional www el
4. pitched sounds will not activate the unit Elation Professional www elationlighting com ELED Fresnel 100WW User Manual Page 11 ELED Fresnel 100WW Warranty 2 YEAR LIMITED WARRANTY A Elation Professionals hereby warrants to the original purchaser Elation Profes sionals products to be free of manufacturing defects in material and workmanship for a period of two years 730 days from the date of purchase This warranty shall be valid only if the product is purchased within the United States of America including possessions and territories It is the owner s responsibility to establish the date and place of purchase by acceptable evidence at the time service is sought B For warranty service send the product only to the Elation Professionals factory All shipping charges must be pre paid If the requested repairs or service including parts replacement are within the terms of this warranty Elation Professionals will pay return shipping charges only to a designated point within the United States If the entire instrument is sent it must be shipped in its original package No accessories should be shipped with the product If any accessories are shipped with the product Elation Professionals shall have no liability whatsoever for loss of or damage to any such accessories nor for the safe return thereof C This warranty is void if the serial number has been altered or removed if the prod uct is modified in any manner whi
5. ROL INPUT POWER INPUT OUTPUT DMX512 DMX DMX COMMON 1 2 3 Termination reduces signal errors and avoids signal transmission problems and interference It is always advisable to connect a DMX terminal Resistance 120 Ohm 1 4 W between PIN 2 DMX and PIN 3 DMX of the last fixture 1 2 3 1 2 3 DMX DMX COMMON DMX512 OUT 3 PIN XLR Figure 2 Figure 3 1 Ground 1 Ground XLR Male Socket XLR Pin Configuration 3 Hot 2 Cold 2 Cold 3 Hot XLR Female Socket Pin 3 Data True positive Pin 2 Data Compliment negative Pin 1 Ground Special Note Line Termination When longer runs of cable are used you may need to use a terminator on the last unit to avoid erratic behavior A terminator is a 110 120 ohm 1 4 watt resistor which is con nected between pins 2 and 3 of a male XLR connector DATA and DATA This unit is inserted in the female XLR connector of the last unit in your daisy chain to terminate the line Using a cable terminator ADJ part number Z DMX T will decrease the possibilities of erratic behavior DMX512 IN 3 PIN XLR SOUND REMOTE CONTROL INPUT POWER INPUT OUTPUT SOUND REMOTE CONTROL INPUT POWER INPUT OUTPUT SOUND REMOTE CONTROL INPUT POWER INPUT OUTPUT DMX512 DMX DMX COMMON 1 2 3 Termination reduces signal errors and avoids signal transmission problems and interference It is always advisable to c
6. User Instructions ELED Fresnel 100WW Introduction Elation Professional www elationlighting com ELED Fresnel 100WW User Manual Page 2 7 10 Unpacking Thank you for purchasing the ELED Fresnel 100WW by Elation Professional Every ELED Fresnel 100WW has been thoroughly tested and has been shipped in perfect operating condition Carefully check the shipping carton for damage that may have occurred during shipping If the carton appears to be damaged carefully inspect your fixture for any damage and be sure all accessories necessary to oper ate the unit has arrived intact In the case damage has been found or parts are missing please contact our customer support number for further instructions Do not return this unit to your dealer without first contacting customer support Introduction The ELED Fresnel 100WW is part of Elation Profession als continuing pursuit for creating high quality affordable intelligent fixtures The ELED Fresnel 100WW is a powerful DMX intelligent LED warm white spot The unit can be controlled manually or via DMX con troller Customer Support Elation provides a customer support line to provide set up help and to answer any question should you encounter problems during your set up or initial operation You may also visit us on the web at www elationlighting com for any comments or sugges tions Service Hours are Monday through Friday 9 00 a m to 5 00 p m Pacific Standard Time Voice 323 582 3322
7. any where in the middle When a fixture is assigned a DMX address of 1 the DMX controller knows to send DATA assigned to address 1 to that unit no matter where it is located in the DMX chain Data Cable DMX Cable Requirements For DMX Operation The ELED Fresnel 100WW can be controlled via DMX 512 proto col The ELED Fresnel 100WW can be either a 1 or 2 channel DMX unit The DMX address is set on the back panel of the ELED Fresnel 100WW Your unit and your DMX controller require a approved DMX 512 110 Ohm Data cable for data input and data output Figure 1 We recommend Accu Cable DMX cables If you are making your own cables be sure to use standard 110 120 Ohm shielded cable This cable may be purchased at almost all professional sound and lighting stores Your cables should be made with a male and female XLR connector on either end of the cable Also remember that DMX cable must be daisy chained and cannot be split Figure 1 Notice Be sure to follow figures two and three when making your own cables Do not use the ground lug on the XLR connector Do not con nect the cable s shield conductor to the ground lug or allow the shield conductor to come in contact with the XLR s outer casing Grounding the shield could cause a short circuit and erratic behavior DMX512 IN 3 PIN XLR SOUND REMOTE CONTROL INPUT POWER INPUT OUTPUT SOUND REMOTE CONTROL INPUT POWER INPUT OUTPUT SOUND REMOTE CONT
8. ationlighting com ELED Fresnel 100WW User Manual Page 5 Elation Professional www elationlighting com ELED Fresnel 100WW User Manual Page 6 Power Supply The ELED Fresnel 100WW contains an electronic ballast which will auto sense the voltage when it is plugged into the power source With the electronic ballast you do not need to worry about wall voltage this unit can be plugged in anywhere Also be sure to only use the included I E C power cable supplied with the unit DMX 512 DMX is short for Digital Multiplex This is a universal pro tocol used as a form of communication between intelligent fixtures and controllers A DMX controller sends DMX data instructions from the controller to the fixture DMX data is sent as serial data that trav els from fixture to fixture via the DATA IN and DATA OUT XLR ter minals located on all DMX fixtures most controllers only have a DATA OUT terminal DMX Linking DMX is a language allowing all makes and models of different manufactures to be linked together and operate from a single controller as long as all fixtures and the controller are DMX compliant To ensure proper DMX data transmission when using several DMX fixtures try to use the shortest cable path possible The order in which fixtures are connected in a DMX line does not influence the DMX ad dressing For example a fixture assigned a DMX address of 1 may be placed anywhere in a DMX line at the beginning at the end or
9. ch Elation Professionals concludes after inspec tion affects the reliability of the product if the product has been repaired or serviced by anyone other than the Elation Professionals factory unless prior written authori zation was issued to purchaser by Elation Professionals if the product is damaged because not properly maintained as set forth in the User Manual D This is not a service contract and this warranty does not include maintenance cleaning or periodic check up During the period specified above Elation Profession als will replace defective parts at its expense and will absorb all expenses for war ranty service and repair labor by reason of defects in material or workmanship The sole responsibility of Elation Professionals under this warranty shall be limited to the repair of the product or replacement thereof including parts at the sole discretion of Elation Professionals All products covered by this warranty were manufactured after January 1 1990 and bear identifying marks to that effect E Elation Professionals reserves the right to make changes in design and or improvements upon its products without any obligation to include these changes in any products theretofore manufactured F No warranty whether expressed or implied is given or made with respect to any accessory supplied with products described above Except to the extent prohibited by applicable law all implied warranties made by Elation Pro
10. e 7 3 To run the 1 Channel Mode press the MODE button until XXX1 is displayed This is the DMX addressing for the 1 Channel Mode 4 To run the 2 Channel Mode press the MODE button until XXX2 is displayed This is the DMX addressing for the 2 Channel Mode 3 Please see pages 10 12 for DMX values and traits Master Slave Operation This function will allows you to link units together to run in a Master Slave mode In Master Slave operation one unit will act as the controlling unit and the others will react to the controlling units built in programs Any unit can act as a Master or as a Slave however only one unit can be pro grammed to act as the Master Master Slave Connections and Settings 1 Daisy chain your units via the XLR connector on the rear of the unit Use standard XLR microphone cables to link your units together Remember that the Male XLR connector is the input and the Female XLR connector is the ouput The first unit in the chain master will use the female XLR connector only The last unit in the chain will use the male XLR connector only 2 Set the Master unit to your desired mode of operation 3 For the Slave unit s press the MODE button until XXX3 is dis played 4 Use the UP and DOWN buttons to adjust the address The slave unit must be set to the same address as the Master unit 5 Connect the Slave unit or units and they will automatically start to follow the Master
11. f Companies World Headquarters 6122 S Eastern Ave Los Angeles CA 90040 USA Tel 323 582 3322 Fax 323 832 9142 Web www elationlighting com E mail info elationlighting com
12. fessionals in connec tion with this product including warranties of merchantability or fitness are limited in duration to the warranty period set forth above And no warranties whether expressed or implied including warranties of merchantability or fitness shall apply to this prod uct after said period has expired The consumer s and or Dealer s sole remedy shall be such repair or replacement as is expressly provided above and under no circum stances shall Elation Professionals be liable for any loss or damage direct or conse quential arising out of the use of or inability to use this product G This warranty is the only written warranty applicable to Elation Professionals Products and supersedes all prior warranties and written descriptions of warranty terms and conditions heretofore published ELED Fresnel 100WW Specifications Model ELED Fresnel 100WW SPECIFICATIONS Working Position Any safe working position Voltage 100V 240V 47 63Hz LED s 1 x 100W LED Power Consumption 140W Fuse 4 Amp Weight 11 6lbs 5 3Kgs Dimensions 14 5 L x 9 84 W x 14 5 H Colors White DMX Channels 2 DMX Modes 1 Channel Mode amp 2 Channel Mode Warranty 2 Year 730 days Please Note Specifications and improvements in the design of this unit and this manual are subject to change without any prior written notice Elation Professionals A Division of the AmericanDJ Group o
13. onnect a DMX terminal Resistance 120 Ohm 1 4 W between PIN 2 DMX and PIN 3 DMX of the last fixture 1 2 3 1 2 3 DMX DMX COMMON DMX512 OUT 3 PIN XLR Figure 4 5 Pin XLR DMX Connectors Some manufactures use 5 pin XLR connectors for DATA transmission in place of 3 pin 5 pin XLR fixtures may be implemented in a 3 pin XLR DMX line When inserting standard 5 pin XLR connectors in to a 3 pin line a cable adaptor must be used these adaptors are readily available at most electric stores The chart below details a proper cable conversion Conductor 5 Pin XLR Male In 3 Pin XLR Female Out Pin 1 Do Not Use Do Not Use Pin 3 Pin 2 Pin 1 Pin 3 Pin 2 Not Used Not Used Data True signal Data Compliment signal Ground Shield 3 Pin XLR to 5 Pin XLR Conversion ELED Fresnel 100WW DMX Set Up ELED Fresnel 100WW DMX Set Up Operating Modes Manual Dimmer 1 Plug the fixture in and press the MODE button until XXX4 is dis played 2 Use the UP and DOWN buttons to adjust the LED intensity This onboard control mode is regulated by the max and minimun intenstiy settings These settings are set in the DIM MAX SETTING and DIM MIN SETTING onboard control modes Dim Max Setting The Dim Max Setting will set the maximum dimness level for manual control and DMX mode 1 Plug the fixture in and press the MODE button until XXX5 is dis played 2 Use the UP and DOWN bu
14. rviceable parts inside Never operate this unit when it s cover is removed Never plug this unit in to a dimmer pack Always be sure to mount this unit in an area that will allow proper ventilation Allow about 6 15cm between this device and a wall Do not attempt to operate this unit if it becomes damaged This unit is intended for indoor use only use of this product out doors voids all warranties During long periods of non use disconnect the unit s main power Always mount this unit in safe and stable matter Power supply cords should be routed so that they are not likely to be walked on or pinched by items placed upon or against them paying particular attention to the point they exit from the unit Cleaning The fixture should be cleaned only as recommended by t he manufacturer See page 10 for cleaning details Heat The appliance should be situated away from heat sources such as radiators heat registers stoves or other appliances inclu d ing amplifiers that produce heat The fixture should be serviced by qualified service personnel when A The power supply cord or the plug has been damaged B Objects have fallen or liquid has been spilled into the appliance C The appliance has been exposed to rain or water D The appliance does not appear to operate normally or exhibits a marked change in performance ELED Fresnel 100WW Warranty Registration ELED Fresnel 100WW Features
15. ttons to adjust the maximum value of the LED dimmer The setting can be adjusted between 50 100 Dim Min Setting The Dim Min Setting will set the minimum dimness level for manual con trol and DMX mode 1 Plug the fixture in and press the MODE button until XXX6 is dis played 2 Use the UP and DOWN buttons to adjust the minimum value of the LED dimmer The setting can be adjusted between 0 30 DMX Mode Operating through a DMX controller gives the user the freedom to create their own programs tailored to their own individual needs This function also allows you to use your fixtures as spot lights The ELED Fresnel 100WW has 2 DMX modes 1 Channel mode and 2 Channel mode See page 9 for each modes DMX traits Remember the maximum and minimum dimness levels are set in the Dim Max amp Dim Min Settting menus 1 This function will allow you to control each individual fixture s traits with a standard DMX 512 controller such as the Elation Show Designer or the Elation DMX Operator 2 To run your fixture in DMX mode plug in the fixture via the XLR con nections to any standard DMX controller Select your desired DMX mode and then press the UP or DOWN buttons to adjust the DMX address XXX DMX Address ELED Fresnel 100WW Operating Instructions Elation Professional www elationlighting com ELED Fresnel 100WW User Manual Page 8 Elation Professional www elationlighting com ELED Fresnel 100WW User Manual Pag