Home

EdgeStar ap12000s User's Manual

image

Contents

1. Do not drop the remote control Do not place the remote control in a location exposed to direct sunlight The remote control should be placed about 3 feet or more away from any electrical appliances Battery replacement Remove the cover on the back of the remote control and insert the batteries with the and ends pointing in the correct direction o Oni q o 9 15VO CAUTION A Use only AAA batteries Remove the batteries if the remote control will not be used for a month or longer Do not attempt to recharge the supplied batteries All batteries should be replaced at the same time do not mix old and new batteries Do not dispose of the batteries in a fire as they may explode Operation Control Panel W ater Light Power Button Mode Button Fan Speed Button Power e The power button turns the unit on and off e When you first press the power button the unit will begin to operate in cooling mode After you have used the unit and turned it off it will default to the last used mode settings upon turning the unit on again If power to the unit is interrupted while the unit is running the air conditioner will restart itself in its last used mode settings once power is restored Note This auto restart function will restart the unit after power is restored The compressor will resume after 3 minutes if it was on prior to the interruption
2. abnormal service han dling or usage This warranty does not cover normal wear and tear on parts or replacement of parts designed to be replaced e g filters etc This warranty does not cover service trips to deliver pick up repair or install the product or to instruct in proper usage of the product Damages or operating problems resulting from abuse operation outside environmental specifications uses con trary to instructions provided in the owner s manual accidents vermin fire flood improper installation unauthor ized service unauthorized installation or modification or commercial use are excluded from warranty coverage This warranty does not cover labor incurred 91 days or more after the date of original purchase This warranty does not cover use of EdgeStar products in commercial settings DESCRIPTION OF WARRANTY SERVICE All defective product components covered by this warranty will be repaired or replaced at EdgeStar s option free of charge on a mail in basis to EdgeStar s authorized repair facility during the first 90 days from the date of original purchase All defective product components covered by this warranty will be repaired or replaced at EdgeStar s option on a mail in basis to EdgeStar s authorized repair facility during the time period beginning on the 91st day from the date of original purchase and ending one year from the date of original purchase During this time period parts will be supplied
3. connector Fe VOU CAD asec anendenneramasserireneneneenees 1 Loosen the screws on the plastic window kit 1 and adjust the sliding kit to the width or height of your window Then tighten the screws to secure your adjustments to the window Kit See below images for setup examples 2 Place the grated adapter 2 into the large hole on the flush side of the plastic window kit 1 Line up the 4 holes in the grated adaptor 2 with the pilot holes in the plastic window kit and fasten them togethe with a screw driver 3 Install the plastic window kit 1 into your window If necessary use duct tape to better secure the window kit 4 On the air conditioner connect the duct connector 4 the connector with the smaller slots into the unit by aligning the tabs inside the unit with the slots and snapping them together See Fig 1 Note Once inserted duct connectors cannot be removed 5 Attach the window kit connector 6 the connector with the larger slots onto the exhaust hose 5 by stretching the hose completely out and turning the window kit connector 6 clockwise screwing it into the exhaust hose 5 6 Screw on the exhaust hose 5 to the duct connector 4 by turning it clockwise 7 Move the air conditioner towards the window Align the slots on the window kit connector 6 to the tabs on the grated adapter 2 and snap them together See Fig 2 8 To remove the window kit connector 6 from the grated adaptor 2 push in the tabs on the grat
4. evaporator fan o If the fan spins freely while the unit is off but does not spin when the unit is on then the probable cause is a loose wire from the fan motor to the circuit board or a faulty fan motor Contact customer service to replace faulty wiring or fan motor o If the fan does not spin freely then the probable cause is a broken fan or a foreign object has jammed the fan Contact customer service if fan is broken or unplug unit and attempt to remove foreign object Troubleshooting Why are the control panel lights blinking randomly o Your air conditioner may have a minor electrical fault Move the unit to another outlet or unplug the unit and plug it in again o Your air conditioner may be plugged into an outlet that cannot supply the correct voltage to the unit Move the air conditioner to another outlet and test the outlet with a voltage tester or another appliance that is known to be non defective If the outlet is bad contact an electrician and move the air conditioner to another outlet o If that is not the problem the unit may have a faulty control panel Contact customer service My unit runs for a little while generally about 90 seconds and then suddenly trips its power cord and or the circuit breaker o Your air conditioner may need to be reset Move the unit to another outlet or unplug the unit for 1 minute and plug it in again o Your air conditioner may be plugged into an outlet that cannot supply the co
5. for precise information Description of product Portable Air Conditioner Model AP12000S Voltage Frequency AC 115V 60HZ Input power 950W Color Silver Dehumidifying capacity 81 Pints Day Dimensions i l l W x H x D 17 1 10 x 30 9 10 x 15 Weight 66 Ibs Please recycle where facilities exist Check with your local authority for Waste electrical products should not be disposed of with household waste X recycling advice yciing Warranty _ This EdgeStar product is warranted to be free from defective workmanship and materials for the first year follow ing the date of original purchase Replacement parts will be supplied free of charge for the first year following the date of original purchase Labor will be performed free of charge for the first 90 days following the date of original purchase WHAT IS COVERED This warranty applies to the original purchaser only and only covers defects in workmanship experienced during operation of the product under normal service maintenance and usage conditions This warranty applies to the purchase and use of this product in residential settings within the United States of America WHAT IS NOT COVERED The following limitations apply to the coverage of this warranty Optional accessories attachments and appearance items are excluded from warranty coverage as is shipping damage and any damage caused by improper voltage or any other misuse including
6. mode Fan Speed This unit has 3 fan speeds High Medium and Low Press the speed button to toggle the speeds Temperature To set the temperature in cooling mode use the up and down buttons The temperature setting range is from 61 F 89 F Note When in dehumidifying or fan modes no temperature setting is required or allowed Timer Temp Set Buttons e Used for adjusting the timer and thermostat e The default display is room temperature e In cooling mode you can set the temperature by pressing the A or Y button The set temperature will be displayed for 15 seconds then revert back to room temperature The temperature is only adjustable in cooling mode The time is adjustable between 1 12 hours Note By pressing both of the Timer Temp button the same time the display will toggle between Celsius and Fahrenheit Note The displayed range of the ambient temperature in both celsius and farenheit is from 0 to 99 Any temperature above 99 will be displayed as HI on the indicator and any temperature below 0 will be displayed as LO After turning the air conditioner off wait 3 minutes before turning it back on again Installation Accessories 1 Plastic window Kit ceeeeeeeeeeeee 2 Grated adapte l cccccecceeeeeeeeees io eS 5 ee eee one eee ee 4 Duct connector 1 2 eeeeeeeeeee eee ee eee 5 Exhaust NOS cccceceeeecececeeeeeees 6 Window kit
7. OF INCIDENTAL OR CONSEQUENTIAL DAMAGES SO THE ABOVE EXCLUSION MAY NOT APPLY TO YOU THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS YOU MAY HAVE OTHER RIGHTS THAT VARY FROM STATE TO STATE SSEdgeStar For information on EdgeStar and to view our full line of products please visit our website http www edgestar com EdgeStar Products Box 81336 Austin Texas 78708 1336 Toll Free 1 866 319 5473
8. SSEdseStar AP12000S Portable Air Conditioner Owner s Manual This owner s manual provides instructions on safe installation use and maintenance Please read it carefully and save it for reference Ry http www edgestar com Welcome Welcome and thank you for purchasing this EdgeStar Portable Air Conditioner We are glad you chose us We take pride in knowing that like our products our customer service will be just as dependable Once you complete our easy unit set up by following this manual your portable air conditioner will provide you years of great service Please save the original product packaging in case you need to safely transport this portable air conditioner in the future For your reference Please write down the model and serial number here as they are needed to obtain service for your unit if necessary The two numbers are on the label located on the back of your unit You may also want to staple your receipt to this manual This will provide you with a quick reference as this information is needed for any service under your warranty Model Number Serial Number Date Purchased Need Assistance To better serve you please do the following before contacting our customer service e Read this manual it contains instructions to help you use and maintain your portable air conditoner properly If you received a damaged appliance please contact the dealer that sold you the applianc
9. Water Light This portable air conditioner is designed to exhaust most or all water condensed from the air in cooling mode In high humidity situations the internal water reservoir may fill The unit will automatically shut off and the water light will turn on Once the water is manually drained the unit will operate as normal Modes This unit has 3 settings Cooling Dehumidifying Fan The settings are toggled by the mode button Note Your settings will be indicated on the the control panel with an illuminated LED e Cooling Mode During cooling mode room air is cooled and hot air is exhausted to the outside through the air exhaust hose Adjust the fan speed and temperature to suit your desired comfort level Note The air exhaust hose must be vented through a window when using the cooling mode e Dehumidifying Mode The dehumidifying mode removes water from the air without cooling the room If the room temperature is below 77 F the fan speed will be locked on low above 77 F the fan speed is adjustable Note The exhaust hose is not required in dehumidifying mode Note The internal water tray will fill with water in this mode A Cooling High Dehumidify Medium WATER Fanony Low Display EdgeStar Om Timer Temp Set Button e Fan Mode This unit has 3 fan speeds High Medium and Low Press the speed button to toggle the speeds Note The unit does not need to be vented in fan
10. e immediately e Read the section titled troubleshooting This section will help you solve common problems that might occur If you do require service our friendly and efficient customer service representatives are available online via email at service edgestar com or by telephone at 1 866 319 5473 Warning Improper handling may cause serious damage to the unit Read this manual carefully before operating the unit i Do not wet the housing or Do not cover the air Do not allow children to play control panel outlet while unit is in with the controls or drop any USE objects into the air outlet Do not place objects or Always turn the unit off and Do not attempt to remove any let any person sit on top remove the power plug from part of the casing unless by an the socket when cleaning authorized technician of the unit Remove the plug from Use only the correct power Do not operate the unit with a the socket if the unit is supply AC115V 60Hz damaged plug or loose outlet not going be used for a long period of time i Make sure that the back of the unit is at least 4 inches or more away from a wall Do not place the unit in front of curtains or drapes to ensure they do not obstruct the air intake Route the power cord carefully to avoid a tripping hazard Warning e If the power cord on this unit is damaged it must be replaced by the manufacturer its service agent or a qualified person e This appliance is not in
11. ed adaptor 2 and pull the window kit connector 6 away from the grated adaptor 2 9 To remove the window kit connector 6 and duct connector from the exhaust hose twist the connections counterclockwise To remove the grated adaptor 2 unscrew the 4 screws 3 10 The vent cap 7 may be installed on the grated adapter 2 by aligning the slots with tabs and snapping them together when the air conditioner is not in use See Fig 3 Duct Connector Exhaust Hose Window Kit Connector Optimizing Performance For Maximum Performance and Efficiency 1 2 10 11 12 13 14 15 Do not cover the air outlet exhaust while in use Do not place the unit in front of curtains or drapes to ensure they do not obstruct the air intake Minimize the length of the exhaust hose Make sure the exhaust hose is as straight as possible Keep curtains blinds or drapes closed during the sunniest part of the day Use the timer to operate the unit before it is needed For example set the timer to turn on the unit in cooling mode for 3 or more hours to cool the room before you arrive You may want to operate the unit all day if you live in a warmer climate Minimize the heat sources direct sunlight computers servers people etc in the room Close all windows and doors Use the unit in a contained room For example a room with four walls and a roof instead of a partitioned studio or warehouse Make su
12. free of charge but labor charges will apply All replacement parts and units will be new re manufactured or refurbished All products and components replaced by EdgeStar under warranty service become the property of EdgeStar OBTAINING WARRANTY SERVICE Contact EdgeStar for troubleshooting assistance and warranty service authorization at 1 866 319 5473 Please have your order receipt available to confirm the date of purchase Once an EdgeStar authorized representative has confirmed that your product is eligible for warranty service the product must be returned to our EdgeStar repair facility The purchaser is solely responsible for prepaying all shipping related costs to and from the repair facility EdgeStar is not responsible for damage resulting from shipper mishandling or improper packaging Do not return defective product to the place of purchase THIS WARRANTY IS IN LIEU OF ANY OTHER WARRANTY EXPRESS OR IMPLIED INCLUDING WITHOUT LIMITATION ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE TO THE EXTENT ANY IMPLIED WARRANTY IS REQUIRED BY LAW IT IS LIMITED IN DURATION TO THE EX PRESS WARRANTY PERIOD ABOVE NEITHER THE MANUFACTURER NOR ITS DISTRIBUTORS SHALL BE LIABLE FOR ANY INCIDENTAL CONSEQUENTIAL INDIRECT SPECIAL OR PUNITIVE DAMAGES OF ANY NATURE INCLUDING WITHOUT LIMITATION LOST REVENUES OR PROFITS OR ANY OTHER DAM AGE WHETHER BASED IN CONTRACT TORT OR OTHERWISE SOME STATES DO NOT ALLOW THE EXCLUSION
13. hy is my air conditioner not cooling at all o The unit should be in a room where the ambient temperature is below 95 F If the ambient temperature is above 95 F the unit will likely not blow cold air but is not defective Follow the below steps to increase the efficiency of your unit s compressor o Minimize heat in the room o Minimize the size of the area to be cooled close doors and windows o Close curtains or pull down blinds minimize direct sunlight into the room o Remove additional heat sources such as computer equipment servers etc o Run the unit before it is needed e g run the unit in the morning before the area gets hot and continue to run the unit all day long in order to maintain a low temperature o Use more than one unit or a larger unit to cool the area o Remove the exhaust hose and run the unit for 5 minutes Stick your hand in front of the exhaust and then in front of the internal air louvers Is the exhaust noticeably hotter than the interior air If so the unit is not defective follow the above steps to maximize efficiency of your unit s compressor o If your unit has a filter the filter may be dusty or otherwise blocked Clean the filter or contact customer service to replace if necessary o Check to make sure the air intake or exhaust ports are not partially obstructed If they are remove the obstruction My unit turns on but one of the fans is not turning or makes a loud noise Exhaust and
14. nt Never spray water onto the main unit Replace the activated carbon filter 2 The activated carbon filter cannot be cleaned T ne and needs to be disposed of when cleaning the ery pre filter EdgeStar sells replacement activated carbon O filters Contact customer service via email at service edgestar com or by telephone at 1 866 319 5473 to purchase additional activated carbon _ filters J 3 J Maintenance and Storage 1 If you are not going to use this unit for a long time be sure to drain the water from the reservoir by removing the drain cap and the rubber plug 2 Before storing the unit run it in fan mode for a few hours to dry any moisture on the coils to prevent mold 3 Turn the unit off clean the air filter and reinstall it 4 Remove the exhaust hose and connectors and keep them in a safe place Troubleshooting Why is my air conditioner not functioning at all Oo The air conditioner may not be receiving electrical power Press the test reset buttons on the LCDI power cord o Move the air conditioner to another outlet and test the outlet with a voltage tester or another appliance that is known to be non defective If the outlet is bad contact an electrician and move the air conditioner to another outlet o If the remote will not work first check the batteries The control panel may be unplugged from the circuit board Contact customer service to repair W
15. re the unit is on a level surface Minimize the amount of humidity in the room For example adding a dehumidifier To prolong the compressor s life please wait at least 3 minutes before turning the unit back on after shutting it off Inspect and keep the pre filters clean by cleaning regularly Inspect and replace the activated carbon filters regularly Perform routine maintenance Maintenance i A a i Appliance maintenance Air filter maintenance Gp Cut off the power supply It is necessary to clean or replace the air filters periodically Clean as follows Stop the appliance and 4 remove the activated carbon filter and the pre filter The activated carbon filter attaches to the standard pre filter The activated carbon filter removes smoke odors and other harmful particles while the pre filter removes dust Turn off the appliance first before disconnecting from the power supply Wipe with a soft and dry cloth Use lukewarm water below 104 F to clean the appliance Never use volalile substances such as gasoline or polishing powder to clean the appliance Clean and reinstall the pre filter Dirt can be cleaned off the pre filter by washing it with a solution of soap in lukewarm water After cleaning the pre filter allow it to air dry in shaded and cool place then reinstall Clean the pre filter every two weeks if the air conditioner operates in a dusty environme
16. rrect voltage to the unit Move the air conditioner to another outlet and test the outlet with a voltage tester or another appliance that is known to be non defective If the outlet is bad contact an electrician and move the air conditioner to another outlet My air conditioner is too loud o Your air conditioner may be positioned on a hard or uneven floor causing your unit to vibrate Move the unit onto a level carpeted surface o If the unit is level and a knocking noise is audible the unit may have a faulty compressor Contact customer service Why is my air conditioner leaking o Check for damage to the bottom of the unit If damage is present contact customer service o Make sure the unit on a level surface o Make sure you are running the unit with the drain plug installed Make sure the drain cap as well as the rubber drain plug is attached to the unit Both fans are blowing but only room temperature air is coming out of both fans o Make sure the unit is on cooling mode o Note that the compressor may take up to 3 minutes to turn on o Check to see if there is any oily residue on the bottom of the unit or inside the unit on the panels or components If this is the case then the compressor has a cracked coil that is leaking oil and the unit must be replaced Contact customer service to replace Specifications s Figures noted in the contents are for reference only consult the label on your air conditioner
17. tended for use by children e This appliance is intended for domestic use only Operation AM Air Conditioner Remote Control The functions work the same as your air conditioner s touch controls All key functions can be accessed from the remote control Power Button On Off Mode Button Press this button to change the operation mode in the order of Fan Speed Button P kog Cooling gt Dehumidifying Bo Fan e l HIGH MED LOW Time Temperature Buttons Used for adjusting the timer and temperature The default display on control panel is room temperature When or key is pressed in cool mode the set temperature is displayed and may be adjusted After 15 seconds the display will revert back to room temperature Timer setting is available from 1 12 hours by pressing either Q or Timer Button Setting the Timer If the unit is on e Press the timer button Use the and buttons to set the time displayed in hours e After the selected time elapses the unit will automatically shut off If the unit is off e Press the timer button Use the and buttons to set the time displayed in hours e Then select which mode you want the unit to Note automatically start in and make the necessary adjustments e After the selected time elapses the unit will automatically turn on

Download Pdf Manuals

image

Related Search

Related Contents

SF-1500 fog machine user manual  Guardian® Indoor Pet Barrier System Operating  FRIDAM ACTI SP  製品マニュアル(詳細スペック)  ISTR456R-2 foglieeee  取扱説明書  

Copyright © All rights reserved.
Failed to retrieve file