Home

Eaton 9155 User's Manual

image

Contents

1. And with 240 customer service engineers in North America and 1 200 international authorized service providers Eaton has more service personnel than any other UPS manufacturer The standard factory warranty covers e System warranty Two year parts 90 days labor e Battery warranty Two years parts 90 days labor Extensive service options for enhanced reliability For support beyond the warranty period Eaton offers enhanced service options including onsite startup corrective and preventive maintenance battery solutions training remote monitoring and factory spare parts and upgrades Customizable three phase UPS services packages allow customers to select the plan that provides the right combination of system uptime convenience and value Service Plans Comprehensive coverage of the UPS and batteries Telephone technical Support Connectivity support Expedited delivery of replacement parts modules and batteries On site startup On site corrective maintenance Next day 24 hr response UPS preventative maintenance Battery preventative maintenance A EATON CORPORATION 9155 UPS Factory On Site On Site Gold Warranty Gold Plus Y Y Y Y Y Y Y Y Y Y r Y Y Y Y Y Y Y Y Connectivity amp manageability Enhanced communication capabilities The 9155 UPS is equipped with a variety of standard communications features for network connectivity and remote management applications including e RS 232 serial
2. 1200000 K4101300000 K4121100000 K4121200000 K4121300000 K4151100000 K4151200000 K4151300000 Description PW9155 Model 8 32 Battery 2 high PW9155 Model 8 64 Battery 3 high PW9155 Model 8 32 Battery with Transformer 3 high PW9155 Model 10 32 Battery 2 high PW9155 Model 10 64 Battery 3 high PW9155 Model 10 32 Battery with Transformer 3 high PW9155 Model 12 32 Battery 2 high PW9155 Model 12 64 Battery 3 high PW9155 Model 12 32 Battery with Transformer 3 high PW9155 Model 15 32 Battery 2 high PW 9155 Model 15 64 Battery 3 high PW9155 Model 15 32 Battery with Transformer 3 high Power Rating kVA kW 8 7 2 8 7 2 8 7 2 10 9 10 9 10 9 12 10 8 12 10 8 12 10 8 15 13 5 15 13 5 15 13 5 Input amp Output Connection Hardwired Hardwired Hardwired Hardwired Hardwired Hardwired Hardwired Hardwired Hardwired Hardwired Hardwired Hardwired 1 50 60 Hz auto sensing All models can be used for frequency phase conversion with de rated 80 load Please refer to manual for details 2 Input voltage 200 240V with neutral or with optional input isolation transformer Output voltages are user selectable 100 200 110 220 120 240 Vac 180 phase displacement or 120 208 127 220 Vac 120 phase displacement 3 Weight is installed weight add 47 Ibs 2 high models or 50 Ibs 3 high models to determine shipping weight 4 An input neutral is required for all config
3. 40 C lt 3000m at 25 C CERTIFICATIONS Safety Certifications NOM 0190SCFI 1993 UL 1778 CSA C22 2 No 107 3 EN 5502 Class A CISPR22 Class A and IEC 60950 IEC 62040 1 1 IEC 62040 2 FCC Part 15 ICES 003 VCCI ISO 9001 2000 and ISO 14001 1996 UL cUL CSA CE and NOM NYCE 1 Due to continuous product improvements program specifications are subject to change without notice EMC Compliance Quality Markings PowerChain Management ASIA PACIFIC Australia 61 2 9693 9366 New Zealand 64 0 3 343 3314 China 86 21 6361 5599 HK Korea Taiwan 852 2745 6682 India 91 11 4223 2300 Singapore SEA 65 6825 1668 EUROPE MIDDLE EAST AFRICA Denmark 45 3686 7910 Finland 358 94 52 661 France 33 1 6012 7400 Germany 49 0 7841 604 0 Italy 39 02 66 04 05 40 Norway 47 23 03 65 50 Portugal 55 11 3616 8500 Sweden 46 8 598 940 00 United Kingdom 44 1753 608 700 Eaton PowerChain Management ABM ConnectUPS LanSafe PowerVision Powerware Hot Sync and X Slot are trade names trademarks and or service marks of Eaton Corporation or its subsidiaries and affiliates All other trademarks are property of their respective owners 2010 Eaton Corporation All Rights Reserved Printed in USA 9155FXA April 2010
4. 96 96 96 7500 6750 13 1 53 2 99 7 151 205 223 99 7 1 8 263 7000 6300 14 6 08 0 109 164 224 39 2 109 194 286 6500 5850 16 3 63 5 119 180 245 38 6 119 212 314 6000 5400 18 4 70 0 131 198 270 42 5 131 234 346 5500 4950 20 1 776 145 220 300 41 2 145 259 383 9000 4500 22 4 86 6 162 245 334 52 6 162 289 428 4500 4050 Zod 97 4 182 2 6 37 6 597 182 325 4000 3600 28 6 110 207 313 426 67 1 207 309 3500 3150 32 8 127 238 359 71 0 238 423 3000 2700 38 3 148 277 48 89 7 211 2500 2250 45 6 170 329 107 329 Note Backup times are approximate and may vary with equipment configuration battery age temperature etc www eaton com 9155_ 1 800 356 5794 3 Options amp service Adaitional 9155 options Wall mount maintenance bypass panels Eaton offers a comprehensive line of optional wall mounted maintenance bypass panels compatible with the 9155 UPS The wall mounted bypass panel is used to bypass the UPS during maintenance or servicing providing wrap around bypass for UPS service without shutting down the load And for more flexible power distribution these maintenance bypass panels can be equipped with surge protection and provisions for 36 poles of distribution utilizing Eaton s Cutler Hammer breakers Proven warranty and support services Customers consistently rank Eaton services number one in quality Eaton s comprehensive world class service solutions are designed to improve costs uptime reliability power quality and safety
5. BC 103004192 5501 9155 and 9355 EBM 64 2 high 32 2 x 12 0 x 30 2 480 1030041 93 5501 9155 and 9355 EBM 96 3 high 47 8 x 12 0 x 30 2 710 Notes up to four EBM 64 cabinets or three EBM 96 cabinets can be added to each 8 15 kVA UPS for extended runtime Seismic Mounting Kit 103004194 5501 Seismic Kit Rated Zone 4 UL Tested Performance rating based on NEBS GR 63 CORE Standard Vibration Test Fits both 136 2 amp 3 high models Maintenance Bypass Module MBM BPE20MBB1A Wall mounted Maintenance Bypass Module for 9155 21x14x6 5 31 Eaton 9155 Parallel System Start Up OSTUP9155P10CX 9155 8 10 KVA 2 or 3 Unit Parallel OSTUP9155P15CX 9155 12 15 kVA 2 or 3 Unit Parallel 103004626 9155 Parallel System 2 unit upgrade kit includes Can Bridge Cards Procedures and Parallel User s Guide 103004627 9155 Parallel System 3 unit upgrade kit includes Can Bridge Cards Procedures and Parallel User s Guide Connectivity Options 116750221 001 ConnectUPS X Web SNMP xHub Card 05146288 5501 ConnectUPS MX SNMP Modem Card 9155 only 1035425 5591 Modbus Card 05146508 5501 USB Card 1018460 Relay Interface Card AS 400 Compatible 103003055 Industrial Relay Card 116750224 001 Environmental Probe requires ConnectUPS Web SNMP card Spare Parts 106711155 9155 Spare Parts Kit A Upgrades 103004195 9155 8 kVA to 9155 10 kVA 103004196 9155 12 kVA to 9155 15 kVA Power Distribution Module PDM with Mechanical Bypass Switch Optional Receptacle P
6. Powerware series 8 15 kVA Powering Business Worldwide Product Introduction 9155 8 15 kVA Reliability and efficiency have never looked so attractive The 9155 single phase Uninterruptible Power System UPS delivers a combination of advanced technology user friendly design and low price that s absolutely unmatched by competing products This innovative design offers high efficiency 90 percent or better across all load ranges low input current distortion less than 5 percent total harmonic distortion with an active IGBT rectifier that delivers 0 99 power factor correction and high power factor output 0 9 PF With advances being made in miniaturization and processing power and more equipment being served by dual cord power supplies the challenge of protecting that power and doing so in a limited space grows ever greater Fortunately advances in technology have also meant that more power protection per square foot can now be provided The 9155 delivers premium levels of efficiency reliability and flexibility all in a sleek tower half the size of most other units on the market today 2 EATON CORPORATION 9155 UPS Product Snapshot Technology Split ohase double conversion online UPS 8 kVA 10 kVA 12 kVA and 15 kVA at 0 9 power factor 200 240 Vac with Neutral or with optional input isolation transformer 100 200 110 220 120 240 Vac 180 phase displacement 120 208 127 220 Vac 120 phase displac
7. anels Breaker Voltage Phase 4 5 15R 15A 120V 1 4 5 20R UL 20A 120V 1 4 6 15R 15A 208V 2 4 6 20R 20A 208V 2 4 L5 15R 15A 120V 1 2 L5 20R 20A 120V 1 2 L5 30R 30A 120V 1 2 L6 15R 15A 208V 2 2 L6 20R 20A 208V 2 2 L6 30R 30A 208V 2 2 L14 20R 20A 120 208V 2 2 L14 30R 30A 120 208V 2 Blank panel The combined quantity of these locking receptacle plates must not exceed four www eaton com 9155_ 1 800 356 5794 7 TECHNICAL SPECIFICATIONS for 10 AND 15 kVA POWER Ratings kVA Watts Topology 8 10 12 and 15 kVA at 0 9 power factor True double conversion online UPS Electrical Input Nominal Input Voltage 200V 240V with neutral or with optional input transformer 15 10 from nominal at 100 load without depleting battery 50 60 Hz 45 to 65 Hz PF gt 0 99 typical gt 0 96 frequency converter 5 THD Input Voltage Range Operating Frequency Input Power Factor Input Current Distortion ELECTRICAL OUTPUT Nominal Output Voltage 100 200 110 220 120 240 Vac 180 phase displacement 120 208 127 220 Vac 120 phase displacement Output Voltage 1 Static 5 dynamic at 100 resistive load change Regulation lt 1 ms response time Efficiency 90 typical BATTERY Battery Type 9Ah sealed lead acid maintenance free Battery Runtime See Battery Runtime Chart Battery Replacement Field replaceable Default is 3 4A per battery string Charger current is configurable from 0 5A to 25A per str
8. ement Power Rating Input Voltage Output Voltage Frequency 50 60 Hz auto sensing 32 2 Hx12 Wxo25 D Small footprint tower black Dimensions Configuration Battery Backup Up to 29 minutes typical extendable up to four hours See battery backup charts Features of the Eaton 9155 UPS e A true online double conversion topology protects connected equipment from all nine of the most common power problems e Delivers maximum power density in a compact tower design 12 wide and 33 deep Including batteries e Provides more real power in less space 5 500 watts per square foot with a 0 9 output power factor protecting more equipment for every utility dollar and leaving more room for expansion of the data center e Patented Powerware Hot Sync paralleling of multiple modules delivers extra capacity or redundancy e Customizable output distribution provides user specified power outlets along with terminals for connecting hard wired equipment e Microprocessor controlled ABM technology significantly increases battery life e Provides a 0 99 input power factor and generator friendly lt 5 total harmonic distortion using an active IGBT rectifier to control the input power factor e Ensures data and system integrity with complete power management software for remote monitoring management and shutdown e An Eaton factory limited warranty technical support and optional service plans provide investment p
9. ing with an overall maximum of 34A limited by input current Charger Start On Battery Allows start of UPS without utility input GENERAL Diagnostics Full system self test at startup UPS Bypass Automatic on overload or UPS failure Parallel for Redundancy Yes using Powerware Hot Sync technology and Capacity Dimensions and Weights See Model Selection Table Overload 150 for 5 sec 125 for 1 min online Normal Operation 110 for 10 min COMMUNICATIONS LCD Display Graphical LCD with blue backlight LEDs 4 LEDs for notice and alarm Audible Alarms Yes Communication Ports 1 RS 232 1 relay contact 1 REPO 2 environmental input 2 X Slot communication bays Bundled Software Suite CD Software Communication Slot Power Management UNITED STATES 8609 Six Forks Road Raleigh NC 27615 U S A Toll Free 1 800 356 5794 CANADA Ontario 416 798 0112 Toll free 1 800 461 9166 LATIN AMERICA South Cone 54 11 4124 4000 Brazil 55 11 3616 8500 Andean amp Caribbean 1 949 452 9610 Mexico amp Central America 52 55 9000 5252 www eaton com powerquality ETN Powering Business Worldwide ENVIRONMENTAL Operating Temperature 10 C to 40 C 45 C with 7 5 derating Batteries recommended max 25 C 15 C to 25 C 0 95 non condensing Storage Temperature Relative Humidity Audible Noise Audible Noise lt 53 dBA at 1 meter noise less room typical Altitude lt 1000m at
10. lel Cabinet Cabinet Maintenance Bypass Battery innovations optimize battery performance and service life Standard internal batteries provide power until auxiliary power takes over or systems are gracefully shut down Battery runtime can be extended to hours by adding matching Extended Battery Modules EBM Eaton 9155 8 15 kVA UPS Backup Times In Minutes UPS 1 2 3 4 UPS 1 2 3 Internal EBM EBM EBM EBM Internal EBM EBM EBM VA Watt 32Battery 64 64 64 64 64Battery 96 96 96 15000 13500 46 23 0 43 0 65 1 88 6 13 3 43 0 76 7 113 14500 13050 49 24 1 45 2 68 3 93 0 14 1 45 2 805 119 14000 12600 9 2 25 2 473 71 5 974 14 9 473 842 125 13500 12150 TS 26 4 49 4 747 102 15 8 49 4 88 1 130 13000 11700 9 8 27 6 51 6 78 1 106 16 7 91 6 92 0 136 12500 11250 6 1 28 8 54 0 81 6 111 17 6 04 0 96 2 142 12000 10800 6 5 30 2 56 5 85 5 116 18 6 96 5 101 149 11500 10350 6 9 31 6 59 3 89 7 122 19 2 59 3 106 156 11000 9900 7 3 33 3 624 944 129 20 2 624 111 164 10500 9450 7 8 39 1 65 9 99 6 136 21 4 65 9 117 174 10000 9000 8 4 37 2 69 8 106 144 22 6 69 8 124 184 9500 8550 g1 39 6 74 2 112 153 24 1 74 2 132 196 9000 8100 J9 42 3 79 4 120 163 29 79 4 141 209 8900 7650 10 8 45 9 85 2 129 175 271 6 80 2 152 225 8000 7200 11 9 49 1 91 9 139 189 29 8 91 9 164 242 Eaton 9155 8 15 kVA UPS Backup Times In Minutes UPS 1 2 3 4 UPS 1 2 3 nternal EBM EBM EBM EBM internal EBM EBM EBM VA Watt 32Battery 64 64 64 64 64Battery
11. port e Two X Slot communication bays e Relay output contacts e Two programmable signal inputs e Remote emergency power off REPO Easy network connectivity and monitoring ConnectUPS X card The ConnectUPS X Web SNMP X Slot card connects the 9155 directly to an Ethernet network and the Internet and enables graceful shutdown of multiple computers over the network The ConnectUPS X Web SNMP also features a three port switching hub Modbus card The Modbus card is an X Slot device that allows continuous real time monitoring of the 9155 through a Building Management System BMS or industrial automation system Relay interface cards The relay interface card for the X Slot enables remote UPS shutdown and provides isolated dry contact Form C relay outputs for utility failure low battery UPS alarm OK and on bypass Environmental Monitoring Probe The environmental monitoring probe EMP works with the 9155 and ConnectUPS X card to remotely monitor ambient temperature and relative humidity of the remote environment The EMP can also be configured to provide Status of two additional contact devices such as smoke detectors or open door sensors ConnectUPS X Web SNMP X Slot card Power Xpert Gateway Card 2000 LanSafe Monitoring Probe Power Xpert Gateway Series cards Power Xpert Gateway Series X Slot cards provide Web enabled real time monitoring of UPSs PDUs and RPPs through standard onboard Web pages Po
12. rotection and peace of mind Premium power protection is now easier than ever With raised floor real estate at a premium you ll appreciate that the 9155 requires only three to six square feet of floor space including internal batteries Such a small footprint gives you more location options and more space available for future expansion Equipment installation is Inexpensive and easy essentially plug and play You can order 9155 models with your choice of more than 19 types of output receptacles To rearrange or add data center equipment you simply unplug from the old receptacle and plug into a new one no need for an electrician to run new conduit and wiring Scalable architecture meets current and future load requirements Eaton 9155 UPSs are available in four models 8 10 12 and 15 kVA so you can choose the configuration that most closely meets your own capacity requirements and price point And you can scale from there Using our signature Hot Sync paralleling technology up to three 9155 modules can be paralleled tor extra capacity or redundancy A 15 kVA UPS for example can grow to support loads of up to 45 kVA There s no dependence on communications wiring among these modules enhancing reliability and simplifying installation This paralleling capability Is far more easily achieved than is the case with competitors products Inside view of 9155 Parallel Powerware Hot Sync Redundant Capacity 9155 UPS Paral
13. urations unless the input isolation transformer is used 5 Depth increases to 33 7 when unit is configured with a PDM Front view of 3 high module with cover off REPO normally open Dimensions Output Receptacles H x W x D in see PDM chart see PDM chart See PDM chart See PDM chart See PDM chart See PDM chart See PDM chart See PDM chart See PDM chart See PDM chart See PDM chart See PDM chart Four button graphical LCD with backlight X Slot Communication Bay 1 Signal Input 1 Signal Input 2 REPO normally closed X Slot Communication Bay 2 EATON CORPORATION 9155 UPS DB 9 Communication Port Relay Contact Fans Internal batteries on slide out trays field replaceable 32 2 x 12 0 x 32 0 471 8 x 12 0 x 32 0 47 8 x 12 0 x 32 0 32 2 x 12 0 x 32 0 47 8 x 12 0 x 32 0 47 8 x 12 0 x 32 0 32 2 x 12 0 x 32 0 41 8 x 12 0 x 32 0 41 8 x 12 0 x 32 0 32 2 x 12 0 x 32 0 47 8 x 12 0 x 32 0 47 8 x 12 0 x 32 0 Unit Weight Ib 352 590 908 352 590 908 392 590 908 352 590 908 Eaton 9155 Accessories Accessories Dimensions Unit Weight Order Number Description H x W x D in Ib Powerware Hot Sync 124100017 001 9155 Parallel Cabinet 24 0 x 20 3 x 2 2 57 3 103004336 Powerware HotSync CAN Bridge Card Notes Up to three 9155 UPS and up to four 9355 UPS available Fall 2005 UPSs can be paralleled with the Parallel Cabinet Extended Battery Module EBM or Cabinets E
14. wer Xpert software or third party software Power Xpert meters Power Xpert meters combine state of the art technology with next generation power diagnostics data trending and performance benchmarking with a twist and click LCD display Centralized control and visibility The 9155 UPS is shipped with the Eaton Software Suite CD The software suite includes the following applications as well as a user friendly wizard to guide users through software selection and installation e LanSate power management software e Intelligent Power Manager e NetWatch network monitoring software eNotify Remote Monitoring Eaton s eNotify Remote Monitoring Service provides 24x7 real time monitoring of the 9155 and battery systems and alerts both service technicians and the customer when a problem is detected Proactive monitoring enables technical experts to respond immediately to more than 40 alarm conditions and in many cases resolve issues remotely with minimal or no downtime Additional eNotify benefits include e One way outbound status and event e mails for security and reliability e Fast diagnosis and notification of critical alarms e Monthly customer reports including power event logs and overall UPS and battery health summaries Foreseer www eaton com 9155_ 1 800 356 5794 Eaton 9155 at a glance Model Selection Table Eaton 9155 UPS 8 15 kVA Order Number K4081 100000 K4081200000 K4081300000 K4101100000 K410

Download Pdf Manuals

image

Related Search

Related Contents

"取扱説明書"  IRIS Touch 600 Series Installation Manual  BBIQ光電話ターミナル iA101SC3 取扱説明書  Craftsman 315.10899 Saw User Manual  Autonomous Prototype of a Full Dimension Continuous Haulage  Secador de Mãos TurboJato AK2006H  Kidde 0910UK Smoke Alarm User Manual  MANUAL TÉCNICO  Sony DSC-T90/B Instruction Manual  