1. Figure 5 Door Adjustment THE BENEFITS OF INSTALLING BLOWER A blower can be installed at the back of your DROLET stove This option is necessary if you wish to redistribute into a room the heat trapped at the back of your stove By forcing hot air toward the front the blower enables you to extend the radiation power of your stove You can purchase this option through your DROLET dealer Make sure to specify this part number AC02050 You can also install a thermodisc to enable the blower to start or stop automatically when the stove is hot or too cold The thermodisc part number is AC05530 Installation instructions are supplied with the blower and the thermodisc 10 INSTALLATION SAFETY NOTICE IF THIS STOVE IS NOT PROPERLY INSTALLED A HOUSE FIRE MAY RESULT TO REDUCE THE RISK OF FIRE FOLLOW THE INSTALLATION INSTRUCTIONS FAILURE TO FOLLOW INSTRUCTIONS MAY RESULT IN PROPERTY DAMAGE BODILY INJURY OR EVEN DEATH CONSULT YOUR MUNICIPAL BUILDING DEPARTMENT OR FIRE OFFICIALS ABOUT RESTRICTIONS AND INSTALLATIONS REGUIREMENTS IN YOUR AREA USE SMOKE DETECTORS IN THE ROOM WHERE YOUR STOVE IS INSTALLED KEEP FURNITURE AND DRAPES WELL AWAY FROM THE STOVE NEVER USE GASOLINE GASOLINE TYPE LANTERN FUEL KEROSENE CHARCOAL LIGHTER FLUID OR SIMILAR LIQUIDS TO START OR FRESHEN UP A FIRE KEEP ALL SUCH LIQUIDS WELL AWAY FROM THE STOVE
2. 6 Install the baffle bricks 4 x 4 1 2 x 9 2 x 3 x 9 on T shape support 7 Finally gently slide the insulation panels over the baffle bricks Nbr Description Qty 1 1 x 41 2 x 9 25 2 1 x 41 2 x 8 3 16 1 3 1 x6 xT 2 i 4 ASH CAP SE09224 1 5 1 3 9 2 lt 6 ISOLATOR 9 x 12 2 gt 7 SUPPORT SE09242 1 Figure 2 1600 Refractory Bricks Assembly BRICK AND INSULATION INSTALLATION 2000 The stove is normally supplied with secondary air tubes in position To install the baffle bricks and white ceramic insulation it s necessary to remove the two front secondary air tubes First place only one baffle brick and one white ceramic insulation Use the same method to put the other baffle brick and insulation Put back in place the secondary air tubes Install the yellow insulation and the 6 x 8 6 x 6 bricks Install the side and bottom bricks SOLATION EN LAINE DAE dee JE CERAMIQUE BLANCHE L PIENE WHITE CERAMIC INSULATION BACK RIQUE CDUPE FE lt UPPHRTEES PAR LES CONDUITS D AIR DE COTE ANNEAUX ISHA Ya AFFLE BRICKS m Ms e PPHSTED BY SIDE AIR CHANNELS YELLOW INSULATID IQUE 6 3 L ARRIERE FIREBRICKS IN BACKS BRIQUES 4 1 2 gt LES COTES ET LE FONI gt 41 FIREBRICKS FOR SIDES AND gt BRIGUE
3. OWNER S MANUAL DROLET EPA WOODSTOVES HT 1600 amp HT 2000 US ENVIRONMENTAL PROTECTION NI D gt AGENCY PHASE II CERTIFIED a Sy WOODSTOVES gt V rified and tested following x ULC S627 et UL 1482 Standards by Portland Oreqon USA gt Tested amp Listed By OMNI Test Laboratories Inc READ AND KEEP THIS MANUAL FOR REFERENCE Manufactured by STOVE BUILDER INTERNATIONAL INC 1700 L on Harmel Qu bec Qu bec 1 4R9 Tel 418 527 3060 Fax 418 527 4311 www drolet ca 45060A TABLE CONTENTS INTRODUCTION ia 2 TECHNICAL SPECIFICATIONS 3 TIPS WOOD HEATING uu u direnir 4 ASSEMBLY rur ames 5 PEDESTAL AND DECORATIVE SIDEWALL 5 BRICKS AND INSULATION INSTALLATION 1600 6 BRICK AND INSULATION INSTALLATION HT 2000 a a 7 AIR TUBES INSTALLATION 2000 4 8 DOOR ADJUSTMENT aa 9 THE BENEFITS OF INSTALLING BLOWER a a 10 INSTALLATION i ul uuu TERES 11 POSITIONING THE STOVE ia 11 FLOOR PROTEC TOP L uuu aa desi
4. For this purpose simply scrub the surface to be repainted with fine sand paper clean it properly and apply thin coats 2 of paint successively Refer to page 18 of the present manual for the paint curing process 26 DROLET LIMITED LIFETIME WARRANTY The warranty of the manufacturer extends only to the original consumer purchaser and is not transferable This warranty covers brand new products only which have not been altered modified nor repaired since shipment from factory Proof of purchase dated bill of sale model name and serial number must be supplied when making any warranty claim to your DROLET dealer This warranty applies to normal residential use only Damages caused by misuse abuse improper installation lack of maintenance over firing negligence or accident during transportation are not covered by this warranty This warranty does not cover any scratch corrosion warping discoloration caused by over firing abrasives chemical cleaners Any defect or damage caused by the use of unauthorized parts or others than original parts void this warranty An authorized gualified technician must perform the installation in accordance with the instructions supplied with this product and all local and national building codes Any service call related to an improper installation is not covered by this warranty The manufacturer may reguire that defective products be returned or that digital pictures be provided to support the
5. IN THE EVENT OF A CHIMNEY FIRE PUSH THE AIR CONTROL FULL CLOSED TO DEPRIVE THE FIRE OF OXYGEN CALL THE FIRE DEPARTMENT DO NOT CONNECT TO ANY AIR DISTRIBUTION DUCT OR SYSTEM A SOURCE OF FRESH AIR INTO THE ROOM OR SPACE HEATED SHALL BE PROVIDED WHEN REQUIRED POSITIONING THE STOVE It is very important to position the wood stove as close as possible to the chimney and in an area that will favour the most efficient heat distribution possible throughout the house The stove must therefore be installed in the room where the most time is spent and in the most spacious room possible Recall that wood stoves produce radiating heat the heat we feel when we are close to a wood stove A wood stove also functions by convection that is through the displacement of hot air accelerated upwards and its replacement with cooler air If necessary the hot air distribution from the stove may be facilitated by the installation of a blower The wood stove must not be hooked up to a hot air distribution system since an excessive accumulation of heat may occur A wood stove must never be installed in a hallway or near a staircase since it may block the way in case of fire or fall to respect required clearances 11 FLOOR PROTECTOR Your wood stove should be placed on a non combustible surface The floor protector should be under the stove eighteen inches beyond the front and eight inches beyond each side of the fuel loading and ash removal opening If
6. claim Returned products are to be shipped prepaid to the manufacturer for investigation If a product is found to be defective the manufacturer will repair or replace such defect and reasonable transportation fees will be refunded Repair work covered by the warranty executed at the purchaser s domicile by an authorized qualified technician requires the prior approval of the manufacturer Labour cost and repair work to the account of the manufacturer are based on predetermined rate schedule and must not exceed the wholesale price of the replacement part All labour and freight costs covered by this warranty are limited according to the table below The manufacturer at its discretion may decide to repair or replace any part or unit after inspection and investigation of the defect The manufacturer may at its discretion fully discharge all obligations with respect to this warranty by refunding the wholesale price of any warranted but defective parts The manufacturer shall in no event be responsible for any special indirect consequential damages of any nature which are in excess of the original purchase price of the product WARRANTY APPLICATION DESCRIPTION H kimama PARTS LABOUR Combustion chamber welds only castings and convector airmate Lifetime i 5 years Plating defective manufacture subject to limitations above Lifetime i Secondary air tubes vermiculite baffle C Cast baffle and handle i 5 years i n a assemb
7. stove if the glass is broken f the glass on your stove breaks replace only with glazing supplied from the Drolet dealer e To replace the glass remove the screws retaining the glass mouldings inside the door Remove the mouldings and replace the damaged piece with a new one Perform the procedure backwards after replacing When replacing the glass you should change the glass gasket to make sure you keep it sealed e Never wash the glass with a product that may scratch Use a specialized product available in the stores where wood stoves are sold e The glass should be washed only when cold GASKETING It is recommended that you change the door gasket which makes your stove door air tight once a year in order to insure good control over the combustion maximum efficiency and security To change the door gasket simply remove the damaged one Carefully clean the available gasket groove apply a high temperature silicone sold for this purpose and install the new gasket You may light up your stove again approximately 24 hours after having completed this operation WARNING e NEVER OPERATE THE STOVE WITHOUT A GASKET OR WITH A BROKEN ONE DAMAGE TO THE STOVE OR EVEN HOUSE FIRE MAY RESULT PAINT Only clean your stove with a dry soft cloth that will not harm the paint finish If the paint becomes scratched or damaged it is possible to give your wood stove a brand new look by repainting it with a 1200 F heat resistant paint
8. there is a horizontal section of chimney connector the floor protector should go under it and two inches beyond each side The floor protector should exceed the stove as follows k FRONT SIDES BACK 18 8 8 460 mm 200 mm 200 mm 12 CLEARANCES Itis of utmost importance that the clearances to combustible material be scrupulously respected upon installation of the stove you have selected Refer to the tables below Figure 6 Clearances to combustibles CANADA Single pipe Double pipe B C D E F HT 1600 20 8 17 8 28 7 28 7 HT 2000 19 10 33 1 28 1 25 5 22 5 Single pipe Double pipe Model B C D E F HT 1600 16 16 1210 20 8 17 8 2000 33 1 28 1 25 5 22 5 e Floor to ceiling height must be at least 7 84 all cases e The clearance between the flue pipe and a wall are valid only for vertical walls and for vertical flue pipe e The flue pipe must not go through roof trussing an attic a wardrobe or similar spaces neither a floor or combustible partition e A flue pipe crossing a combustible wall must have a clearance of 18 minimum e To reduce flue pipe clearances from combustible materials contact your local safety department 13 REDUCED CLEARANCES You may decreas
9. AVEC LE CONDUIT ALL THIMBLE FLUSH WITH FLUE BANDE ISULANTE INSULATIO 19 BRICK THIMBLE CLAY TILE COMBUSTIBLES PS MACONNERIE CONDUIT DE FIRECLAY LINER e NIN UM 20 WOODSTOVE UTILIZATION Your heating unit was designed to burn wood only no other materials should be burnt Wastes and other flammable materials should not be burnt in your wood stove Any type of wood may be used in your stove but specific varieties have better energy yields than others Please consult the following table in order to make the best possible choice Average Energy Yield Of One Air Dried Cord Of Cut Wood Energy yield millions of BTU cord Wood species Oak Sugar Maple Beech Yellow birch Ash Elm Larch Tamarack _Red Maple T Douglas red fir Medium energy yield Silver birch Alder Poplar Hemlock Spruce Pine Bass Fir Data provided by Energy Mines and Resources Canada High energy yield Low energy yield IT IS EXTREMELY IMPORTANT THAT YOU USE DRY WOOD ONLY IN YOUR WOOD STOVE The wood must have dried for 9 to 15 months such that the humidity content in weight is reduced below 20 of the weight of the log It is very important to keep in mind that even if the wood has been cut since one two or even more years it is not necessarily dry if it has been stored in poor conditions under
10. BOUCH BRICK E Figure 3 HT 2000 Refractory Bricks Assembly AIR TUBES INSTALLATION 2000 The secondary air tubes are painted different colours The back tube is yellow the middle on is red and the front is unpainted Before installing make sure the locating holes in the tubes holes near one end of the tube are on the left side Insert one tube in the right side air channel and slide it to the right as much as possible Bring the left end of the tube aligned with the ring welded to the left air channel Move the tube to the left until the locating holes are aligned with those in the ring Insert a cutter pin to hold in place The air injection holes should be facing down in the front and middle tubes TTER PINS S S S ak I 1 BE PAINTE CENTER TUBE FRONT TUBE UNPAINTED Figure 4 Air Tubes Installation DOOR ADJUSTMENT In order for your stove to operate properly the door should be adjusted periodically to provide an air tight fit To adjust e Remove the lock pin spring pin by pulling and turning it using pliers Wise grip e Turn the handle counter clock wise one turn to increase pressure e Re install the lock pin spring pin with a small hammer PORTE DOOR D GOUPILLE RESSORT a LOCK PIN lt PORTE DOOR P N j OUPILLE RESSORT LOCK PIN F
11. ECOMMENDED IN YOUR DROLET WOOD STOVE e NEVER PUT WOOD ABOVE THE FIREBRICK LINING OF THE FIREBOX CREOSOTE FORMATION AND NEED FOR REMOVAL When wood is burned slowly it produces tar and other organic vapours which combine with expelled moisture to form creosote The creosote vapours condense in the relatively cool chimney flue of a slow burning fire As a result creosote residue accumulates on the flue lining When ignited this creosote makes an extremely hot fire When burning wood the chimney connector and chimney should be inspected at least once every two months during the heating season to determine if a creosote build up has occurred We strongly recommend that you install a magnetic thermometer on your smoke exhaust pipe approximately 18 above the stove This thermometer will indicate the temperature of your gas exhaust fumes within the smoke exhaust system The ideal temperature for these gases is somewhere between 275 F and 500 F Below these temperatures the build up of creosote is promoted Above 500 degrees heat is wasted since a too large quantity is lost into the atmosphere TO PREVENT CREOSOTE BUILD UP e Always burn dry wood This allows clean burns and higher chimney temperatures therefore less creosote deposit e Leave the air control fully open for about 10 min every time you reload the stove to bring it back to proper operating temperatures The secondary combustion can only take place if the firebox is hot e
12. ce Heating Capacity Efficiency Average Emission Colour Flue Pipe Diameter Chimney type Minimum Chimney Height Dimensions Overall On Pedestal Model Combustion Chamber Volume Door Opening Pyroceram Glass Door Width x Height Mass OPTIONS Blower 75 CFM 2 83 m min with Width x Depth Width x Height HT 1600 u Wood 900 1 600 ft 84 149 m 40 000 BTU h 11 7 kW 70 000 BTU h Metallic Black 6 152 mm 2 100 F 650 C 12 3 66 m WxDxH 25 1 8 x 26 Ve x 32 5 8 638 x 673 x 828mm 18 15 464 x 387 mm 2 5 pi 0 07 m 17 34 x 9 1 8 425 x 222 mm 16 1 4 x9 vg 432 x 267 mm 420 lbs 190 Kg Wood 1 000 2 000 ft 93 186 m 60 200 BTU h 17 6 kW 95 000 BTU h Metallic Black 6 152 mm WA 2 100 650 C 12 3 66 m WxDxH 28 3 8 x 29 Ve x 34 3 8 721 x 749 x 873mm 22 Vo x 18 572 x 457 mm 3 4 pi 0 09 m 17 3 4 x 9 1 8 450 x 234 mm 16 1 4 x 9 1 2 413 x 241 mm 560 Ibs 254 Kg TIPS WOOD HEATING Wood is renewable energy It is also very clean heat source when used with appliances that are certified by the U S Environmental Protection Agency EPA a standard accepted in Canada as well EPA certified wood stoves are different than conventional wood stoves Burning with an EPA certified wood stove may therefore require that you modify some of
13. chieved between 0 95 kg h and 4 9 kg h under the same conditions Real operating conditions may give very different results than those obtained in the lab according to the species of wood used its moisture content the size and density of the pieces the length of the chimney altitude outside temperature 23 RELOADING Once you have obtained a good bed of embers you should reload the unit In order to do so open the air controls to makimum a few seconds prior to opening the stove s door Then proceed by opening the door very slowly open it one two inches for 5 to 10 seconds before opening it completely to increase the draught and thus eliminate the smoke which is stagnant state of slow combustion in the stove Then bring the red embers to the front of the stove and reload the unit For optimal operation of your wood stove we recommend you operate it with a wood load approximately equivalent to the height of fire bricks It is important to note that wood combustion consumes ambient oxygen in the room In the case of negative pressure it is a good idea to allow fresh air in the room either by opening a window slightly or by installing a fresh air intake system on an outside wall Refer to page 16 of the present manual WARNINGS e NEVER OVERFIRE YOUR STOVE IF ANY PART OF THE STOVE STARTS TO GLOW RED OVER FIRING IS HAPPENING READJUST THE AIR INTAKE CONTROL AT A LOWER SETTING THE INSTALLATION OF A LOG CRADLE IS NOT R
14. d draught the total length of the coupling pipe should never exceed 8 to 10 24 to 3 04 m Except for cases of vertical installation cathedral roof style where the smoke exhaust system can be much longer and connected without problem to the chimney at the ceiling of the room There should never be more than two 90 degrees elbow in the smoke exhaust system Installation of a barometric draught stabiliser fireplace register on a smoke exhaust system is prohibited Furthermore installation of a draught damper is not recommended Indeed with a controlled combustion wood stove the draught is regulated upon intake of the combustion air in the stove and not at the exhaust 4 Stove Pipe 16 TYPICAL INSTALLATIONS FACTORY BUILT CHIMNEY RAIN CAP k ROOF FLASHING WALL RADIATION SHIELD WALL SUPPORT 18 CLEARANCE B Wall installation E Vertical installation RADIATION SHIELD CEILING SUPPORT 17 MASONRY CHIMNEY Clean out door Clay liner 27 s Thimble 18 FACTORY BUILT THIMBLE IS CIMENT EMENT SCRE CONDUIT DU PASSE MUR EGALITE
15. dia eno deed 12 GLEARANGES uu usaha pana n 13 REDUCED CLEARANCES u 14 all zar e as 15 CHIMNEY CONNECTOR STOVE PIPE tnn GR hack xxu ii a ci c 16 TYPICAL INSTALLATIONS c 17 WOODSTOVE UTILIZATION 0 21 22 FIRST FIRES EE 22 22 HEATING n 23 RELOADING 24 CREOSOTE FORMATION AND NEED FOR 24 ASH DISPOSA Li e 25 MAINTENANCE er 26 CIE P Y Sis 26 Cu c gc 26 PAIN u S OE c 26 DROLET LIMITED LIFETIME WARRANTY aad rk eno excea 27 REGISTER YOU WARRANTY ONLINE To receive full warranty coverage you will need to show evidence of the date you purchased your stove Keep your sales invoice We also recommend that you register your warranty online at www drolet ca Registering your warranty online will help us track rapidly the information we need on your stove INTRODUCTION SBI INC one of the
16. e the clearances by installing heat radiation shields between the walls the ceiling and the stove These heat radiation shields must be installed permanently and can include sheet metal a rigid non combustible sheet or a masonry wall Clearances of not less than 1 25 mm and not more than 3 76 mm between the bottom of the shield and the floor and not less than 3 76 mm between the top of the shield and the ceiling must be respected to allow vertical air circulation behind the shield The shield must extend 20 500 mm above the stove top and 18 450mm to each side of the stove Following the installation of such a heat radiation shield the clearances mentioned on the stove certification plate may be reduced as stated in the following table Reducing Clearances With Shielding Sides and Rear Back TYPE OF PROTECTION Sheet metal a minimum of 0 013 0 33 mm spaced out at least 7 8 21 mm by non combustible spacers Ceramic tiles an equivalent non combustible material on fire proof supports spaced out at least 7 8 50 21 mm by non combustible spacers Ceramic tiles or an equivalent non combustible material on fire proof supports with a minimum of 0 013 0 33 mm sheet metal backing spaced out at least 7 8 21 mm by non combustible spacers Brick spaced out at least 7 8 21 mm by non combustible spacers Brick with a minimum of 0 013 0 33 mm sheet metal backing spaced out at l
17. east 7 8 21 mm by non combustible spacers 67 Source CSA Standard B365 1991 Table 4 Page 27 14 CHIMNEY Your wood stove may be hooked up with a factory built or masonry chimney If you are using a factory built chimney it must comply with UL 103 or ULC S629 standards therefore it must be a Type HT 2100 It is extremely important that it be installed according to the manufacturer s specifications If you are using a masonry chimney it is important that it be built in compliance with the specifications of the National Building Code It must be lined with fire clay bricks metal or clay tiles sealed together with fire cement Round flues are the most efficient The interior diameter of the chimney flues must be identical to the stove s smoke exhaust A flue which is too small may cause draught problems while a large flue favours rapid cooling of the gas and hence the build up of creosote and the risk of chimney fires Note that it is the chimney and not the stove which creates the draught effect your stove s performance is directly dependent on an adequate draught from your chimney The following recommendations may be useful for the installation of your chimney 1 Do not connect this unit to a chimney flue serving another appliance 2 It must rise above the roof at least 3 0 9 mm from the uppermost point of contact 3 The chimney must exceed part of the building or other obstruction with
18. extreme conditions it may even rot instead of drying The vast majority of the problems related to the operation of a wood stove are caused by the fact that the wood used was too damp or had dried in poor conditions These problems can be e ignition problems creosote build up causing chimney fires low energy yield blackened windows incomplete log combustion 21 Smaller pieces of wood will dry faster All logs exceeding 6 in diameter should be split The wood should not be stored directly on the ground Air should circulate through the cord A 24 to 48 air space should be left between each row of logs which should be placed in the sunniest location possible The upper layer of wood should be protected from the element but not the sides TESTING YOUR WOOD When the stove is thoroughly warmed place one piece of split wood about five inches in diameter parallel to the door on the bed of red embers Keep the air control fully open by pulling on it and close the door If ignition of the piece is accomplished within 90 seconds from the time if was placed in the stove your wood is correctly dried If ignition takes longer your wood is damp If your wood hisses and water or vapour escapes at the ends of the piece your wood is soaked or freshly cut Do not use this wood in your stove Large amounts of creosote could be deposited in your chimney creating potential conditions for a chimney fire THE FIRST FIRES The fresh paint on y
19. heat transfer to rooms upstairs Use a mobile home approved stove if you are going to install your wood heating system in a mobile home A fresh air kit must be connected to the stove Never install your wood stove in a bedroom Burn only dry cordwood Make sure you have a good bed of red coals before you load your stove with logs exceeding 3 inches in diameter Read and keep you owner s manual It will provide you with tips on how to runa successful wood heating system ASSEMBLY PEDESTAL AND DECORATIVE SIDEWALL INSTALLATION Figure 1 HT 2000 Pedestal Installation 1 2 3 Remove all bricks and insulations in the appliance Slowly lay down the stove on his back Install legs or the pedestal with the supplied nuts and bolts Stand up the stove and place it with the required clearances Note that there is eight holes in the bottom of the stove but only four will align with the pedestal Slide the front part of the pedestal base around the pedestal and fix the rear part with the two supplied screws Slide the ash pan in position BRICKS AND INSULATION INSTALLATION 1600 1 Remove from the stove all bricks and insulation 2 Install all side bricks 11 x 4 1 2 x 9 amp 1 x 4 x 8 3 16 as shown in drawing below 3 Install the back bricks 6 x 4 1 2 x 9 4 Install the bottom bricks 4 x 4 1 2 x 9 2 6 8 and the ash cap 5 Install the T shape support
20. in 10 3 04 m distance by a height of 2 0 6 m 4 Installation of an interior chimney is always preferable to an exterior chimney Indeed the interior chimney will by definition be hotter than an exterior chimney being heated up by the ambient air in the house Therefore the gas which circulates will cool more slowly thus reducing the build up of creosote and the risk of chimney fires 5 The draught caused by the tendency for hot air to rise will be increased with an interior chimney 6 Using a fire screen at the extremity of the chimney requires regular inspection in order to insure that it is not obstructed thus blocking the draught and it should be cleaned when necessary 15 CHIMNEY CONNECTOR STOVE PIPE Your chimney connector and chimney must have the same diameter as the stove outlet If this is not the case we recommend you contact your dealer in order to insure there will be no problem with the draught The stove pipe must be made of aluminized or cold roll steel with a minimum thickness of 0 021 or 0 53 mm It is strictly forbidden to use galvanized steel Your smoke pipe should be assembled in such a way that the male section of the pipe faces down Attach each of the sections to one another with three equidistant metal screws The pipe must be short and straight All sections installed horizontally must slope at least 1 4 inch per foot with the upper end of the section toward the chimney To insure a goo
21. ly i i Stainless steel baffle and parts 5 years i 3 years Carbon steel baffle and parts 0 00 Lyear Blowers thermal switches rheostat and other controls 2years 1 year 4 pm gaskets insulation and ceramic glass thermal breakage i yeat WA Pictures required Shall your unit or a components be defective contact immediately your DROLET dealer Prior to your call make sure you have the following information necessary to your warranty claim treatment e Your name address and telephone number e Serial number and model name as indicated on the Bill of sale and dealer s name nameplate fixed to the back of your unit e Nature of the defect and any relevant information 27 Before shipping your unit or defective component to our plant you must obtain from your DROLET dealer an Authorization Number Any merchandise shipped to our plant without authorization will be refused automatically and returned to sender 28
22. most important wood stove and fireplace manufacturers in Canada congratulates you on your purchase and wishes to help you get maximum satisfaction from your wood stove In the pages that follow we will give you advice on wood heating and controlled combustion as well as technical specifications regarding installation operation and maintenance of the model you have chosen The instructions pertaining to the installation of your wood stove comply with ULC S627 and UL 1482 standards Read this entire manual before you install and use your new stove If this stove is not properly installed a house fire may result To reduce the risk of fire follow the installation instructions Failure to follow instructions may result in property damage bodily injury or even death Consult your municipal building department or fire officials about restrictions and installations requirements in your area and the need to obtain a permit Keep this instructions manual for future references CAUTIONS HOT WHILE IN OPERATION KEEP CHILDREN CLOTHING AND FURNITURE AWAY CONTACT MAY CAUSE SKIN BURNS DO NOT USE CHEMICALS OR FLUIDS TO IGNITE THE FIRE DO NOT LEAVE THE STOVE UNATTENDED WHEN THE DOOR IS SLIGHTLY OPENED DO NOT BURN WASTES FLAMMABLE FLUID SUCH AS GASOLINE NAPHTHA OR MOTOR OIL DO NOT CONNECT TO ANY AIR DISTRIBUTION DUCT OR SYSTEM ALWAYS CLOSE THE DOOR AFTER THE IGNITION TECHNICAL SPECIFICATIONS Combustion Type Recommended Surfa
23. nough e Always check for creosote deposit once every two months and have your chimney cleaned at least once a year 24 ASH DISPOSAL Ashes should be removed from the stove every few days or when ashes get to 2 to 3 inches deep Always empty the stove when it is cold such as in the morning Always dispose of ashes in a metal container with a tight fitting lid Place this container on a non combustible floor or on the ground well away from all combustible materials pending final disposal If the ashes are disposed of by burial in soil or otherwise locally dispersed they should be retained in the close container until all cinders have thoroughly cooled CAUTIONS e ASHES COULD CONTAIN HOT EMBERS EVEN AFTER TWO DAYS WITHOUT OPERATING THE STOVE THE ASH PAN CAN BECOME VERY HOT WEAR GLOVES TO PREVENT INJURY e NEVER BURN THE STOVE WITH THE ASH TRAP OPEN THIS WOULD RESULT IN OVER FIRING THE STOVE DAMAGE TO THE STOVE AND EVEN HOUSE FIRE MAY RESULT 25 MAINTENANCE Your Drolet stove is a high efficiency stove and therefore require little maintenance It is important to perform a visual inspection of the stove every time it is emptied in order to insure that no parts have been damaged in which case repairs must be performed immediately GLASS e Inspect the glass regularly in order to detect any cracks If you spot one turn the stove off immediately Do not abuse the glass door by striking or slamming shut Do not use the
24. ore advise you to leave the door slightly opened 1 4 for a 10 to 30 minutes period under supervision in order to allow for good combustion After this time you must close the door and progressively adjust the air control to obtain the desired temperature 22 HEATING Controlled combustion is the most efficient technigue for wood heating because it enables you to select the type of combustion you want for each given situation The wood will burn slowly if the wood stove air intake control is adjusted to reduce the oxygen supply in the combustion chamber to a minimum On the other hand wood will burn quickly if the air control is adjusted to admit a larger quantity of oxygen in the combustion chamber The air intake control on your stove is very simple If you pull on it out completely towards you it is fully open If you push on it until it stops the combustion air is reduced to a minimum The following burn rates will be achieved according to control setting Burn rate Low Medium Medium high High Model HT 1600 full close full open 2000 full close full open HT 1600 Air control HT 2000 Air control OPENING Please note that the HT series stoves do not have the same operating range The HT 1600 type stove burned between 0 93 3 32 kg hr during EPA testing The 2000 serie a
25. our stove needs to be cured to preserve its quality Once the fuel charge is properly ignited only burn small fires in your stove for the first four hours of operation Never open the air control more than necessary to achieve a medium burn rate Make sure that there s enough air circulation while curing the stove The odours could be smelled during the 3 or 4 first fires Never start your stove outside You will not be able to see if you are over heating IGNITION After making sure that the stove air intake controls are fully open completely pull out towards you place several rumpled sheets of paper in the centre of the combustion chamber Place 8 to 10 pieces of small dry kindling wood over the paper in the form of a tent You may also place a few pieces of heating wood but choose the smaller ones No chemical product should be used to light the fire Before igniting the paper and kindling wood it is recommended that you warm up the chimney This is done in order to avoid back draft problems often due to negative pressure in the house If such is the case open a window slightly near the stove and twist together few sheets of newspaper into a torch Light up this paper torch and hold it as close as possible to the mouth of the pipe inside the combustion chamber to warm up the chimney Once the updraft movement is initiated you are ready to ignite the stove by lighting the paper and kindling wood inside the combustion chamber We theref
26. your heating habits To get the most satisfaction out of your new wood heating system please make sure you go through the following check list The chimney is the engine that drives the wood heating system Use chimney that is UL listed with an inner diameter to match the stove s outlet collar 6 for all Drolet wood stoves Try to run the chimney inside the building for as much length as you can A tall and warm chimney will produce a good draft Try to install your chimney straight up and avoid 90 degree turns in the flue pipe and offsets in the chimney Make sure that the chimney is tall enough and its top is clear of obstacles so it can produce a stable draft Use a chimney thermometer installed at a distance of approximately 18 inches on the flue pipe above the stove Flue gases should reach at least 3500F before you close the stove s primary air intake completely Operate your unit within the comfort zone indicated on the thermometer To reduce the risk of smoke spillage into the room upon reloading your stove leave the primary air intake completely open for a few minutes This will heat up the chimney and build up draft before you open the stove door Maximize hot air circulation Our wood stoves are designed to easily receive a variable speed blower that will improve heat distribution in front of the stove Remember that wood stoves produce radiant heat Since heat rises the use of floor traps will greatly improve the

Download Pdf Manuals

image

Related Search

Related Contents

iSCSI RAID ストレージ装置  Manual del propietario ABRE-PUERTAS DE  A Solar - Infobuild energia  A-9010 - Onkyo  Benutzerhandbuch GEE-Programm Teil Modellierer Version 3.5  Ergotron Neo Flex Neo-Flex Mobile MediaCenter LD  dreamGEAR Smart Shield  Philips S9311/84 User's Manual  ER-130V series /ER-110VL EasyRECORD User Manual  Q16 EDU Manual Cover  