Home

Dolby Laboratories DP600 User's Manual

image

Contents

1. Gi E e o V i Feet ebe e E S 5 Connect power Rear panel USB ports L Connect upper Ethernet port to network Figure 2 2 Connect DP600 to Network Dolby DP600 Program Optimizer Manual 9 Using the DP600 2 2 Starting the System for the First Time A Caution Before starting the system be sure it s connected to an active network The DP600 touch screen provides a user friendly interface where you perform actions by pressing the respective screen area The touch screen is calibrated during the manufacturing process When you start the DP600 for the first time the DP600 Welcome screen appears which provides a checklist of things you need before you can set up the system as shown in Figure 2 3 Welcome to the DP600 Installation Wizard Your Network Settings including hostname gat A USB Memo and ab the internet for registering the unit and downloading the license file at anytime to exit the Installation Wizard It will automatically start next time cancel finish Figure 2 3 DP600 Welcome Screen To configure the system 1 Be sure you are ready to proceed by checking the Welcome screen then press the right arrow at the bottom of the screen The Network screen appears as shown in the example in Figure 2 4 Before you set up the system the IP address appears only if you enter a static IP address DHCP unchecked If y
2. Figure 2 37 Enter Path Screen Dolby DP600 Program Optimizer Manual 33 Using the DP600 4 Use one of the methods to enter the path to the file or folder for a hot folder that you want to designate for processing then click ok Click the Destination field The Enter Path screen appears In this screen you can enter the path to the file or folder where you want to save the processed files This screen is identical to the Enter Path screen described earlier for the source path 5 Use one of the methods to enter the path to the location where you want to save the processed files then click ok Note You need to set up a shared folder for all authorized users and enter the correct syntax for your source and destination directories as explained in Appendix A 6 If you want to start your work order immediately use the default Immediately in the Start At field If you want to specify a start time for your work order click on the Start At field The Start At screen appears as shown in Figure 2 38 A A A A WER Sep E Moo Y DI Y Y cancel Figure 2 38 Entering the Work Order Start Time 7 Use the up and down arrows to specify a day month year and time when you want to start run the work order then click ok 8 For Hot Folder Pinnacle Hot Folder and Grass Valley Hot Folder work orders see Figure 2 39 if you want to run your work order indefinitely use the default Indefinitely in t
3. The upgrade or clean installation process begins When the new software is completely installed you are prompted to press any key to reboot and to remove the DVD Press any key to reboot and remove the installation disc from the CD DVD drive When the system reboots if the disc is still in the CD DVD drive a clean installation begins Your DP600 touch screen was calibrated during the manufacturing process but you may need to recalibrate the touch screen after a clean installation When the DP600 reboots after a clean installation the calibration setup appears on the front panel touch screen The calibration setup enables you to configure the touch screen so it responds properly To calibrate the touch screen you need to proceed as follows within approximately 30 seconds from the time it appears If you do not proceed within this time period the calibration screen disappears A small target appears at the upper left corner of the calibration setup and a cross appears at each of the other three corners as shown in Figure 3 16 To calibrate the touch screen e Press the target at the upper left corner for a couple of seconds until it changes to a cross The cross at the upper right corner changes to a target e Press the target at the upper right corner until it changes to a cross e Continue the above procedure at the lower left corner and the lower right corner When the calibration is complete the DP600 Welcome screen appear
4. A EeEt 3 d se id ii 28 e e 35 so 0 0 ES 38 41 scan interval enes neister ae rasan 35 SOULCO ehe re anas e See 32 58 64 Stable period titi 35 standard described iii iia 27 SECO tii iaa 32 E E 34 POr il 32 Dolby DP600 Program Optimizer Manual 93
5. Currently there are five types of work orders e Standard e Pinnacle Standard e Hot Folder e Pinnacle Hot Folder e Grass Valley Hot Folder Standard and Pinnacle Standard Work Orders These type of work orders process audio on a file by file basis You specify the path to the source file on your PC or anywhere on the network You also specify a destination where you want to save the processed file Pinnacle work orders are designed specifically for Pinnacle Systems MediaStream server files Hot Folder Work Order With this type of work order you specify the path to a source folder on your PC or network where the audio files you want to process are located The DP600 periodically looks for files of a specific type in this folder which is controlled by the work order profile The work order profile associated with your hot folder also determines how the DP600 processes the files In addition you specify the destination where you want to save the processed files Dolby DP600 Program Optimizer Manual E Using the DP600 When the DP600 sees the specified file type in the source directory it processes those files according to the current profile and then saves the processed files in the destination folder Note You can link only one work order profile with a single hot folder However you can create multiple hot folders each with a different profile Pinnacle Hot Folder Work Order This type of hot folder i
6. Galibrate But Eeer ege EE EES 25 Calibration Setup ore iuris daria 25 Power Seregi EE 26 Reboot DP600 Confirmation Prompt ccccceeceeeeceeeeeeeeeeeeeeeeeeeaeeeceeeeseaaeeseeeeeesaeeeeeneees 26 DP600 Program Optimizer Splash Screen sesssseesssessresiresrrsssrnrsrnestnnstnnnnnnsnnnsennssrnns 29 DP600 Client Home SCLC A vercion aa 30 Displaying the Work Order Green 31 Adding a Work ee EE 31 Add Workorder Green 32 Selecting a Work Order Tye AANEREN 32 Enter Path Green 33 Entering the Work Order Start Time 34 Hot Folder and Grass Valley Hot Folder Options Pinnacle Hot Folder Options are the same as Hot Folder Options Grass Valley Hot Folder Shows Additional Options 34 Entering the Work Order End Time For Hot Folders amp Grass Valley Hot Folders Only 35 Selecting a Work Order Profile AA 36 Work Order Running as Displayed in Home Screen oococonicccinoccconaccccnonncononnncnnncn nano nannnnccnnn 37 Dolby DP600 Program Optimizer Manual ix List of Figures Figure 2 43 Figure 2 44 Figure 2 45 Figure 2 46 Figure 2 47 Figure 2 48 Figure 2 49 Figure 2 50 Figure 2 51 Figure 3 1 Figure 3 2 Figure 3 3 Figure 3 4 Figure 3 5 Figure 3 6 Figure 3 7 Figure 3 8 Figure 3 9 Figure 3 10 Figure 3 11 Figure 3 12 Figure 3 13 Figure 3 14 Figure 3 15 Figure 3 16 Figure A 1 Figure A 2 Figure A 3 Figure A 4 Figure A 5 Figure A 6 Figure A 7 Figure A 8 Figure A 9 Figure A 10 Figure A 11 Figure A 12
7. 1 with the corresponding physical drive then grasp the drive s finger tab and slide it out of its slot as shown in the example in Figure 3 5 Finger tab Figure 3 5 Remove Failed Drive from DP600 46 Dolby DP600 Program Optimizer Manual Maintaining the DP600 Hard Drives 5 Be sure that no work file is running then grasp the replacement drive s finger tab and firmly but gently slide the drive into its slot see Figure 3 6 until you feel resistance which indicates that the drive is seated in its socket You can replace a drive with a higher capacity unit but not with a lower capacity unit Figure 3 6 Insert Replacement Drive in DP600 6 Position the retaining bracket in front of the hard drives lining it up with the screw holes then use a Phillips screwdriver to tighten its four screws and secure the drives as shown in Figure 3 7 Figure 3 7 Reinstall Retaining Bracket 7 Reinstall the front cover by positioning it so that the mounting tang on the right side of the RAID bay inserts in the mounting slot on the rear of the front cover To do this hold the front cover so that there is an approximately 10 degree angle between the cover and the front of the unit as shown in Figure 3 8 Dolby DP600 Program Optimizer Manual 47 System Maintenance Figure 3 8 Reinstall Front Panel Drive Cover 8 Slide the front cover over the mounting tang and move it to the left until the mounting stud on the left
8. 1l also need access to a computer with an Internet connection and an available USB port You need to obtain a lice for this DP60 g http www dolbysupport com rial number Serial Number 499998 PIN 81479 Insert the flash drive into the DP6 pont and p the Lic button b install it license finish Figure 2 11 License Screen 14 Dolby DP600 Program Optimizer Manual Starting the System for the First Time 15 Obtain the USB flash memory stick from the DP600 packing kit and insert it into a PC connected to the Intern et 16 Open a Web Browser and go to www dolbysupport com 17 If you are already regis 18 If you are a new user please take a few moments to register tered simply log in 19 Once logged in click Product Licensing on the DolbySupport home page as shown in Figure 2 12 A shortcut to DP600 product licenses may also appear under Product Licensing If this shortcut appears you can click on it to go directly to the Get License File page Home lt Product Registration Product Information Click Product Product Licensing Licensing gen or DP600 Get Applications License Shortcut pm rch DolbySupport ran My Account F Log on UE Dolby Support com Resources for Dolby products Welcome Your last visit to this site was Tuesday April 15 2008 Dolby User Forums Added to Dolby Support On the left side of this pag
9. 6 gt GXF File 5 1 2 2 PCM Normalization to 27 LKFS Process gt Speech based Loudness GXF File with a 5 1 and Estimation and SE to 27 LKFS for evt File with a 5 1 and two 2 two 2 PCM programs gt gt PCM programs normalized to S En Measurement Type gt Speech based ITU R SE BS 1770 Profile GXF_GXF 6 normalizes a 5 1 channel PCM and two two channel PCM programs contained in the GXF file resulting in a speech level normalized to 27 LKFS for both Note that tracks 1 6 pairs 1 3 are treated as a single 5 1 program and tracks 7 and 8 pair 4 and 9 and 10 pair 5 are treated as two channel programs Other configurations are not supported by this profile Profile GXF_GXF 7 gt GXF File PCM Tracks 1 4 Normalization to 27 LKFS Process gt Speech based Loudness A Estimation and normalization to 27 LKFS GXF File with PCM on EE SE SU y p Tracks Y 8 Y Only Se Measurement Type gt Speech based ITU R normalized to 27 LKFS BS 1770 Profile GXF_GXF 7 normalizes a two channel PCM program on tracks 1 and 2 and a two channel PCM program on tracks 3 and 4 contained in the GXF file resulting in a speech level normalized to 27 LKFS for both Note that tracks 1 and 2 pair 1 is treated as a single program and tracks 3 and 4 pair 2 is also treated as a single program Other configurations are not supported by this profile 3 media type 18 tracks channels are p
10. Check Names button to verify that the account exists on your system Click the OK button Be sure permissions for the added user is set to Full Control Click the OK button The share should now be set up correctly E O ber Ei NN RRR RP RP k RP RP PQ UA POO AN DT FF WN r o Dolby DP600 Program Optimizer Manual 57 Setting Up a Shared Folder and Entering a Path A 2 Entering a Path When you add a work order you need to enter the Source path to the file or folder for a hot folder that you want to designate for processing In addition you need to enter the Destination path to the location where you want to save the processed files You can enter Source and Destination paths using any of the following three methods e Entering a URL e Browsing e Selecting a bookmark Following is a description of each of these methods Note Supported file system protocols include FTP SAMBA CIFS and SFTP A 3 Entering a Source Path To enter a source path 1 Select home gt work orders gt add The Add Workorder screen appears as shown in Figure A 1 Hot Folder Click Source field Figure A 1 Add Workorder Screen 2 Click on the Source field in the Add Workorder screen The Enter Path screen appears as shown in Figure A 2 58 Dolby DP600 Program Optimizer Manual Entering a Source Path Figure A 2 Enter Path Screen A 3 1 Entering a URL to Specify a Pa
11. Ethernet ee EE 8 Client e E des E EG 27 formats home SE is 30 medial a EA az 4 TUDO ti ii iO tie iets 29 front panel coded audio types c ccicocicininonacinincncnonanancncncncnraranncncnnos 4 COMPONEN tS ii ikea outset eS 5 EE 23 gateway address 11 date and time general configuration m cccccncocononcnnoncnrororoncacirananonraroso 11 network SettingS oconcoconcnconooncnnrncrrnrcrnaronos 12 Grass Valley hot folder TECONFISUTING ccccccconononoccnnnnaninnnononanannncnonananananonono 24 des iio 28 RI LEE 12 A an a r a An ie 32 display control button ococonicncnnnninaninonininonaninaninonanos 6 hardware installation ooooocnconononnnoncnnnaronnnnnnnrnn 9 19 DP600 home screen application iii 4 front pal EE 20 audio types A tases teva vars aoa E tees a ttoweuetseates 11 SUP POLE deeg 4 hot folder COMPON N S o EE 5 described iii eii esosditta cites 2e 3 rele A A Es 1 Grass Valley drive TESTA iii dit 28 internal ici 44 48 SEISCHING ii 32 Tebo cani ci 49 Pinnacle formats TES ege ad 28 s pported msn raene ean vocthangisioss tenses 4 SA NEE 32 front palio 5 work order TEMOVIN E ee ee 44 deserbed ci iad A A AE OTR 27 hardware installation ccccccscceesecseceeeeees 9 19 A O E EEAS 32 alten E E cti iii iaraa 20 IS aia ida at da 12 Id E AER E ASE 3 IPTV applicattons EE 4 LEDs LEDs Internal AVES tias 6 43 DP600 POWER AAA A 6 internal driv S oooncoccnonoononononnnonccononinonncnnnos 6 43 power Supply cococcccconocacanina
12. Manual 85 DP600 Program Optimizer Detailed Profile Descriptions Profile GXF_GXF 2 gt GXF File Dolby E dialnorm Correction and PCM Normalization to 27 LKFS Process gt Speech based Loudness Estimation and dialnorm correction Dolby E GXF File with Dolby E amp PCM normalized to 27 LKFS ER Ee e amp PCM Tracks 3 Measurement Type gt Speech based ITU R HUE Sool OIE BS 1770 Profile GXF_GXF 2 corrects the dialogue normalization value in all Dolby E programs contained on all GXF audio tracks when the measured dialogue loudness is greater than the original dialogue normalization value by 1 dB All PCM audio tracks contained within pairs of GXF tracks media type 18 as defined in Table 5 of SMPTE 360M 2004 are normalized resulting in a speech level normalized to 27 LKFS Profile GXF_GXF 3 gt GXF File Dolby E and PCM Normalized to 27 LKFS Process gt Speech based Loudness Estimation and normalization to 27 LKFS for l GXF File with Dolby E Dolby E and PCM tracks men GXF File with Dolby E amp PCM amp PCM Tracks tracks normalized to 27 LKFS Measurement Type gt Speech based ITU R BS 1770 Profile GXF_GXF 3 normalizes all Dolby E programs and PCM audio tracks contained within pairs of GXF tracks media type 18 as defined in Table 5 of SMPTE 360M 2004 resulting in a speech level normalized to 27 LKFS Profile GXF_GXF 4 gt GX
13. Measurement Type gt Speech based ITU R BS 1770 Multiprogram WAVE Extensible File PCM w Metadata Chunk dialnorm set correctly Profile GXF_PCM 1 decodes all Dolby E streams within a GXF file to a single multiprogram PCM wav extensible files with a Dolby metadata chunk Note that the dialogue normalization value for each program in the audio metadata chunk is set correctly 88 Dolby DP600 Program Optimizer Manual Profile Descriptions Profile GXF_AC3 1 gt GXF File with Dolby E Transcoded to Dolby Digital ac3 Files sl Dolby Digital AC 3 GXF File with Dolby E Process gt Dolby E decode gt Speech based Loudness Estimation for all Dolby E programs gt Dolby Digital encode for each E program with dialnorm set correctly Measurement Type gt Speech based ITU R BS 1770 ac3 File d Program 1 dialnorm set correctly ac3 File Dolby Digital AC 3 Program n dialnorm set correctly Profile GXF_AC3 1 transcodes all Dolby E tracks within a GXF file to ach files one for each program contained in Dolby E Encoded output data rates are automatically provisioned at either 384 kbps for six channel audio or 192 kbps for two channel audio The dialogue normalization value is also automatically provisioned to the correct value for all AC 3 programs contained in the Dolby E stream Note that any two channel PCM programming non Dolby E data found
14. Metadata and Metadata Are Analyzed and Corrected File Broadcast Media File with Dolby E Dolby Digital or Dolby Digital Plus Analyzed and Corrected File Broadcast Media or Multichannel WAV File Without Metadata n channels Dolby DP600 Program Optimizer Manual Work Flow Integration 1 1 Work Flow Integration You can integrate the DP600 into an existing file based network infrastructure where the unit functions as an intelligent processing node In this environment the DP600 adapts to your day to day operations and work flow which includes e Program ingest audio transcoding and quality control Newly ingested content can be routed through the DP600 for loudness analysis and correction encoding decoding and transcoding processes before being moved to your media storage library or play out server e Postproduction File based Dolby E Dolby Digital and Dolby Digital Plus bitstreams can be encoded and decoded to and from multichannel wav or Broadcast WAV Format BWF files with metadata included in the Dolby audio metadata chunk File based media and audio assets can be analyzed logged and if necessary corrected in faster than real time before delivery to clients e Ad insertion Newly ingested ad content can be passed directly to the DP600 for loudness analysis and correction before it s placed in your storage archive or ad server e Video on demand VOD Customer facing VOD servers
15. Seeerei do eege eee 64 LED Sai ad 6 select bookmark ocoococococnconnononaconanonanonnnonanocnns 63 terrestrial broadcast applications ococononiocninononnoso 4 SOULCE Nail Adi is 58 WINE ZOMG O 13 Uli daa 59 touch screen pay Per VIEW iii EEN 4 A a 55 PEA iia ae 8 AA rr e ii a 5 Pinnacle hot folder recalibra tng iii iii in tintes 25 described sad sic 28 upgrade e EE 32 GI O 22 Pinnacle standard work order upper interface settings ooo 12 described ninia nds nin tdi 27 USB port Si Bee EEEE 32 front pelin 5 postprod ction AAA 3 E ER E power video op demand eene 3 LEDS E 6 work flow power Supplies ek 8 A ergeet Ee hee 3 power supply e Ee 3 DP600 work order SAA 51 54 Cancellation 40 LEDS uriena vaeedtsshaaeasees 6 EES led 31 37 power supply indicator dataDaSC iii ai sd 37 front panela iii 5 deleted a 40 profile description Te EE 27 detallando aiii 67 89 destination cocoocconooonoononnnonncnnccononnconnonancnnonnnons 34 65 AAA Ne PEE E ons 3 COL AO 40 PS 2 POT E 8 enda a E ET 34 quality control aococooiionoonitoiacdicn desc vaosansreresontton 3 exporting TeportS snis 40 rear panel COMPONENTS EEN 8 92 Dolby DP600 Program Optimizer Manual Index Grass Valley hot folder described nuit aaa 27 Selec insista ii 32 hot folder described linia dit 27 e a 32 TT 38 PIU A AS ASS 40 Pinnacle hot folder described iii a a 27 SCIC CHS siii seh teases iria 32 Pinnacle standard described ui id ido 27 e a 32
16. Summar export INFO SS report 6 of 6 Figure 2 46 Detailed Report Displayed in Reports Info Screen When you press or click any of the lower four icons only work order reports associated with that icon appear When you press or click again on the same icon this type of report no longer appears If you click more than one icon the respective reports appear corresponding to all the selected icons Following is a description of each icon Selecting this icon displays any work order reports that contain information but no warnings or errors o Selecting this icon displays any work order reports that contain warnings Selecting this icon displays any work order reports that contain errors 27 21 P When you click on a work order report and then click this icon displayed O only in the DP600 Client the system saves a text file of the report to the deeg desired location on your PC A confirmation dialog box appears where you enter the desired name and path and then click ok as shown in Figure 2 47 Dolby DP600 Program Optimizer Manual 39 Using the DP600 TEST15_AC3_DN_20 mpg_Dolby_Digital_Decode_Log_ingestFile estream 00000001 00000025 00000081 TEST15_AC3_DN_20 mpg_Loudness_Correction_Log_ingestFile estream 00000001 00000025 00000081 TEST15_AC3_DN_20 mpg_Dolby_Digital_Decode_Log_ingestFile estream 00000001 00000025 00000081 Ire Documents and Settings psuth Desktop DP600_Export cancel Fi
17. button appears as shown in Figure 2 27 calibrate Figure 2 27 Calibrate Button 3 Press the calibrate button The calibration setup appears with a small target at the upper left corner and a cross at each of the other three corners as shown in Figure 2 28 To calibrate the touch screen you need to proceed as follows within approximately 30 seconds from the time it appears If you do not proceed within this time period the calibration screen disappears e Press the target at the upper left corner for a couple of seconds until it changes to a cross The cross at the upper right corner changes to a target e Press the target at the upper right corner until it changes to a cross e Continue the above procedure at the lower left corner and the lower right corner When the calibration is complete the calibrate button reappears and you can now move on to any other screen as required Press target Figure 2 28 Calibration Setup Screen Dolby DP600 Program Optimizer Manual 25 Using the DP600 Rebooting and Shutting Down the System To reboot or shut down the system system 1 Press power in the system ef screen The power screen appears as shown in Figure 2 29 Figure 2 29 Power Screen 2 To reboot or shut down the system press reboot or shutdown respectively A confirmation prompt asks if you re sure you want to reboot or shutdown the DP600 as shown in the example in Figure 2 30 for a rebo
18. can automatically set or correct the dialnorm parameter by referencing a user defined target level see Figure 1 2 The Model DP600 C adds faster than real time file based encoding and decoding of Dolby Digital and Dolby Digital Plus and the first file based implementation of Dolby E In addition this model enables multichannel audio transcoding of Dolby E to Dolby Digital or Dolby Digital Plus formats It also provides a unique high quality single step Dolby Digital to Dolby Digital Plus transcoder that preserves the metadata and minimizes tandem coding losses This allows the audio from existing media archives to be converted to next generation broadcast formats Dolby DP600 Program Optimizer Manual Introduction Dolby DP600 Program Optimizer 9 PRH Uncorrected File Broadcast Media File with Dolby E Dolby Digital or Dolby Digital Plus Analyze Audio esi y Analyze Dolby Metadata 01101010011010100111001101110000 Audio Stream Already OK Update Correct Metadata Figure 1 1 Coded Audio with Metadata Analysis and Correction Dolby DP600 Program Optimizer Uncorrected File Broadcast Media or Ke Multichannel WAV File Analyze Digital Audio Without Metadata n channels Bi wg Al User Defined Target Level xx dBFS Audio Loudness Already at Target Level No Correction Needed Scale Loudness Level Figure 1 2 Audio Analysis and Correction for Audio Types Without
19. drives recreating the original mirrored RAID array manual rebuild not required For instructions on replacing a drive see Replacing a Drive on page 44 Table 1 1 Local Storage LED Conditions Front Panel LED Condition Failed Physical Drive 1 Solid red 1 1 Blinks in red in 2 two second intervals 1 Blinks in red in Rebuilding RAID half second intervals 2 Solid red 3 3 Solid red 4 Solid red 5 1 5 6 USB 2 0 Port The front panel USB 2 0 port is provided for license loading from a USB flash drive or to connect the provided USB keyboard Dolby DP600 Program Optimizer Manual 7 Introduction 1 6 DP600 Rear Panel The DP600 rear panel includes the following components e Dual redundant power supplies with red alarm reset button e Two PS 2 ports To connect a PS 2 keyboard and or mouse e Four USB 2 0 ports To connect a USB flash drive for license loading and or a USB keyboard and mouse e Two 10 100 1000BASE T Ethernet ports with auto detection To connect to your network upper port currently active lower port reserved for future use e SVGA monitor port To connect a monitor which mirrors the front panel touch screen e Two fans e Two serial ports for future use e Audio ports for future use e Three empty PCI slots for future use Figure 1 5 shows the currently active components on the DP600 rear panel Red alarm reset button Fans Monitor port o
20. e z B Kaffeetassen auf das Ger t F r das sichere Funktionieren des Ger tes und zur Unfallverh tung elektrischer Schlag Feuer sind die folgenden Regeln unbedingt einzuhalten o Der Spannungswahler muf auf Ihre Netzspannung eingestellt sein o Die Sicherungen m ssen in Typ und Stromwert mit den Angaben auf dem Ger t bereinstimmen o Die Erdung des Ger tes mu ber eine geerdete Steckdose gew hrleistet sein O o Das mitgelieferte Netzkabel mu wie folgt verdrahtet werden Phase braun Nulleiter blau Erde griin gelb NORME DI SICUREZZA IMPORTANTE Questa apparecchiatura stata costruita in accordo alle norme di sicurezza EN60950 1 Il prodotto non deve essere sottoposto a schizzi spruzzi e gocciolamenti e nessun tipo di oggetto riempito con liquidi come ad esempio tazze di caff deve essere appoggiato sul dispositivo Per una perfetta sicurezza ed al fine di evitare eventuali rischi di scossa lettrica o d incendio vanno osservate le seguenti misure di sicurezza o Assicurarsi che il selettore di cambio tensione sia posizionato sul valore corretto o Assicurarsi che la portata ed il tipo di fusibili siano quelli prescritti dalla casa costruttrice o L apparecchiatura deve avere un collegamento di messa a terra ben eseguito anche la connessione rete deve C1 avere un collegamento a terra o Il cavo di alimentazione a corredo dell apparecchiatura deve essere collegato come segue Filo tensione Marrone Neutro Blu Massa
21. ensure safe operation and to guard against potential shock hazard or risk of fire the following must be observed o Ensure that your mains supply is in the correct range for the input power requirement of the unit o Ensure fuses fitted are the correct rating and type as marked on the unit o The unit must be earthed by connecting to a correctly wired and earthed power outlet o The power cord supplied with this unit must be wired as follows Live Brown Neutral Blue Earth Green Yellow IMPORTANT NOTE DE SECURITE Ce materiel est conforme a la norme EN60950 1 Ne pas exposer cet appareil aux claboussures ou aux gouttes de liquide Ne pas poser d objets remplis de liquide tels que des tasses de caf sur l appareil Pour vous assurer d un fonctionnement sans danger et de pr venir tout choc lectrique ou tout risque d incendie veillez observer les recommandations suivantes o Leselecteur de tension doit tre plac sur la valeur correspondante votre alimentation r seau o Les fusibles doivent correspondre la valeur indiqu e sur le materiel O o Le materiel doit tre correctement reli a la terre o Le cordon secteur livr avec le materiel doit tre cabl de la mani re suivante Phase Brun Neutre Bleu Terre Vert Jaune WICHTIGER SICHERHEITSHINWEIS Dieses Ger t entspricht der Sicherheitsnorm EN60950 1 Das Ger t darf nicht mit Fl ssigkeiten Spritzwasser usw in Ber hrung kommen stellen Sie keine Gef
22. experience without impacting day to day operations e Automatic hot folder ingest process Users can create hot folders and predefine a work order profile for each one The profile governs the DP600 s behavior with specific broadcast media types All media files moved to a hot folder are automatically processed based on the folder s profile and delivered to a user defined folder upon completion Hot folders are easy to set up and use and can greatly speed integration time within some facilities Dolby DP600 Program Optimizer Manual 3 Introduction 1 3 Applications The DP600 platform has many applications in terrestrial satellite cable and IPTV broadcasting Cable and IPTV Applications e Automated VOD file analysis and loudness correction e Automated VOD file transcoding MPEG 1 LII to Dolby Digital AC 3 Dolby Digital AC 3 to Dolby Digital Plus E AC 3 e Automated digital program insertion DPI file analysis and loudness correction e Automated broadcast media file GXE others audio transcoding Dolby E to Dolby Digital Dolby E to Dolby Digital Plus Dolby Digital to Dolby Digital Plus e Automated broadcast media file quality control and loudness correction Satellite Applications e Automated broadcast media file GXF others audio transcoding Dolby E to Dolby Digital Dolby E to Dolby Digital Plus Dolby Digital to Dolby Digital Plus e Automated broadcast media file quality control and loudn
23. not attempt to service this equipment unless you are qualified to do so 2 Do not defeat the safety purpose of the polarized or grounding type plug A polarized plug has two blades with one wider than the other A grounding type plug has two blades and a third grounding prong The wide blade or the third prong is provided for your safety If the provided plug does not fit into your outlet consult an electrician for replacement of the obsolete outlet 3 This apparatus must be earthed grounded by connecting to a correctly wired and earthed power outlet 4 Ensure that your mains supply is in the correct range for the input power requirement of the unit 5 In order to reduce the risk of electrical shock the power cord must be disconnected when the power supply assembly is removed 6 This equipment is designed to mount in a suitably ventilated 19 rack ensure that any ventilation slots in the unit are not blocked or covered 7 CAUTION This equipment contains a lithium battery Danger of explosion if the battery is incorrectly replaced Replace only with the same or equivalent type Do not disassemble crush puncture short external contacts or dispose of in fire or water Dispose of the used battery in accordance with local law 8 The mains power disconnect device for this unit is the plug in mains cord rather than a power switch The mains cord must remain readily accessible for disconnecting mains power Dolby DP600 Pro
24. on the desired file or folder then click ok Your path appears in the Enter Path screen as shown earlier in Figure A 3 Click ok in the Enter Path screen Your path appears in the Add Workorder screen as shown earlier in Figure A 4 62 Dolby DP600 Program Optimizer Manual Entering a Source Path If you want to create a bookmark click on the desired file or folder in the Select File screen click add bookmark and then click ok as shown in Figure A 10 lol mercury users common ams DP600_Hot_Folder G Glick add bookmark koma to create a bookmark H remove bookmark server connect Figure A 10 Create Bookmark Name URI cancel The Add Bookmark screen appears with the bookmark s file folder name and URL displayed Enter a unique name for your bookmark in the Name field as shown in the example Figure A 11 then click ok Your bookmark appears in the Bookmarks pane at the left side of the Select File screen as shown in the example in Figure A 10 It also appears in the Choose a bookmark drop down menu in the Select Source Path screen where you can select it to specify a path as shown in Figure A 12 DP600_Hot_Folder on mercury smb mercury users common ams DP600_Hot_Folder Figure A 11 Add Bookmark Screen Dolby DP600 Program Optimizer Manual 63 Setting Up a Shared Folder and Entering a Path A 3 3 Selecting a Bookmark to Specify a Path To select a bookma
25. the redundant power supplies has failed and the temperature of the unit Oo Power This green LED lights when the DP600 has power 90 Power supply failure This red LED is off during normal operation It lights or flashes red if either of the redundant power supplies fails ol Temperature This tricolor LED glows green when the temperature of the unit is cool yellow if the temperature is warm and red if the temperature is hot If this LED is yellow or red the operating environment may be warmer than expected and in need of modification In such a case call your Dolby authorized technical representative immediately 1 5 5 Internal Drive Indicators of The DP600 has five physical internal hard drives Drives 1 and 2 are arranged ina e6 RAID 1 configuration to provide protection for the operating system as well as S local storage The remaining three hard drives are configured as separate drives to provide local storage This configuration of one RAID pair and three separate drives represents four logical drives There are four bicolor LEDs on the front panel labeled 1 2 3 and 4 These LEDs indicate the status of the DP600 s four logical internal hard drives The drive LEDs function as follows Off non illuminated Indicates a functional drive with no current disk access activity Green Indicates normal drive activity Red Indicates a drive failure LED 1 shows the status of the two d
26. word is placed in the 20 most significant bits of each wav audio sample word Also note that only source files containing either six or eight channels are supported As a result a two channel source file generates an error condition and is not processed Profile PCM_WAV E 4 gt wav PCM File to NTSC 24 Hz Dolby E Encoding Process gt Dolby E Encoding 24 Hz WAVE w WAVE PCM gt SMPTE 337M formatted Dolby E Program Config gt 5 1 2 or 5 1 only Dolby E Profile PCM_WAV E 4 encodes PCM wav files into 24 Hz Dolby E The output way file contains 25 Hz Dolby E formatted per SMPTE 337M 20 bit mode Note that the output wav file which contains the 20 bit Dolby E data utilizes 24 bit audio sample words Therefore each 20 bit Dolby E data word is placed in the 20 most significant bits of each wav audio sample word Also note that only source files containing either six or eight channels are supported As a result a two channel source file generates an error condition and is not processed Profile WAV AC3_PCM 1 gt Dolby Digital 337M Formatted wav to wav Extensible PCM with Metadata Chunk WAVE File w WAVE Extensible File SMPTE 3 Dolby Digital AC 3 Process gt Dolby Digital AC 3 to PCM 37M formatted Y re gt PCM AC 3 Decoder Operating Mode Line eT Meda Oak Profile WAV AC3_PCM 1 decodes a Dolby Digital AC 3 file formatted per SMPTE 337M 340M wrappe
27. 0 AC 3 to 3 2L AC 3 with Loudness estimate amp correction NOTE ac3 files with 1 0 3 2 amp 3 2L acmod types are supported w o upmixing i e Loudness estimate A correction ONLY ac3 file ac3 file Measurement Type gt Speech based ITU R BS 1770 Profile AC3_AC3 2 automatically upmixes 2 0 stereo ac3 files to 3 2L ac3 at 384 kbps and also corrects the metadata values dialnorm dynrng and compr if the measured dialogue loudness is greater than the original dialnorm value by 1 1dB Note This profile also supports 1 0 3 2 and 3 2L ac3 source files which only pass through the loudness analysis and correction processes that is the upmixer is adaptively bypassed in such cases Dolby DP600 Program Optimizer Manual e DP600 Program Optimizer Detailed Profile Descriptions Profile AC3_EC3 1 gt Dolby Digital AC 3 to Dolby Digital Plus E AC 3 Transcode Process gt Dolby Digital AC 3 to Dolby Digital Plus E AC 3 Transcoder j Output datarate s ac3 file 1 0 96kbps gt i ec3 file 2 0 128kbps 3 2L 224kbps Profile AC3_EC3 1 directly transcodes an ac3 file to an ec3 file where ec3 is a Dolby Digital Plus file type All metadata is preserved in this profile except for the output data rate For 1 0 mono sources the output data rate is 96 kbps For 2 0 stereo sources the output data rate is 128 kbps For 2 1 sourc
28. 9 the DP600 Client home screen appears on your PC This screen looks similar to the home screen on the front panel touch screen and you can perform many of the same functions using the Client You can also perform some additional functions The Client functions are described on the following pages When a procedure says click something this means that you can perform the respective function only with the Client If it says press or click this means you can perform the respective function using the touch screen or the Client 09 23 Di home o Queue Length 0 Workorders El CH OH El work orders reports system Figure 2 32 DP600 Client Home Screen 30 Dolby DP600 Program Optimizer Manual Creating a Work Order Creating a Work Order To create a work order 1 Click work orders near the upper left corner of the home screen Click work orders Queue Length 0 Workorders Figure 2 33 Displaying the Work Order Screen The work orders screen appears as shown in Figure 2 34 In this screen you can add and configure a work order and perform other related functions 2 Click add at the right side of the work orders screen DO DP600 o ES work orders AH no items SS Figure 2 34 Adding a Work Order Dolby DP600 Program Optimizer Manual 231 Using the DP600 The Add Workorder screen appears as shown in Figure 2 35 In this menu you can enter information in the displayed fields to con
29. BILITY OF SUCH DAMAGES Dolby Pro Logic and the double D symbol are registered trademarks of Dolby Laboratories Part Number 91963 Dialogue Intelligence is a trademark of Dolby Laboratories S08 18709 19636 All other trademarks remain the property of their respective owners Issue 2 O 2008 Dolby Laboratories All rights reserved ii Dolby DP600 Program Optimizer Manual Regulatory Notices FCC NOTE This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with this instruction manual may cause harmful interference to radio communications Operation of this equipmentin a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Canada This Class A digital apparatus complies with Canadian ICES 003 EU EMC This is a class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures Important Safety Instructions 1 CAUTION Troubleshooting must be performed by a trained technician To reduce the risk of electric shock do
30. C3_PCM 1 decodes an ec3 Dolby Digital Plus file to a wav extensible file The output file also contains a Dolby metadata chunk Note that the E AC 3 decoder operating mode is Line mode with scale factors set to 1 0 Profile EC3_PCM 2 gt Dolby Digital Plus E AC 3 to wav Extensible PCM with Metadata Chunk f fl i Process gt Dolby Digital Plus E AC 3 to PCM WAV Extensible File w Metadata Chunk an 4 sel E AC 3 Decoder Operating Mode Custom no Metadata applied Profile EC3_PCM 2 decodes an ec3 Dolby Digital Plus file to a wav extensible file The output file also contains a Dolby metadata chunk Note The E AC 3 decoder operating mode is Custom that is no metadata applied Profile PCM_AC3 1 gt wav PCM to Dolby Digital AC 3 Encoding with Speech Based Loudness Estimation and dialnorm Provisioning Process gt Speech based Loudness WAVE Estimation and dialnorm provisioning Process gt PCM to Dolby Digital AC 3 a PCM TI NOTE Multichannel WAVE PCM files are supported s a Measurement Type gt Speech based ITU R BS 1770 Profile PCM_AC3 1 encodes PCM wav files to Dolby Digital AC 3 with the correct dialogue normalization value Note that only two or six channel files are supported in this profile where the AC 3 encoder acmod value is either configured through the nchannels field in the wav format chunk or the acmod field wi
31. CM_UPMIX gt wav PCM file Upmixing to Multichannel PCM wav Multichannel WAVE Process gt 2 channel to 5 1 Channel Upmix S 3 PCM NOTE 1 0 3 2 amp 3 2L source files are passed through WAV Eier dal w Metadata Chunk Profile PCM_UPMIX upmixes two channel wav files to 5 1 channel 3 2L multichannel wav files The upmixed output file is formatted as a multichannel wav extensible file with a Dolby metadata chunk Note One channel five channel 3 2 and six channel 3 2L source wav input files processed by this profile pass through that is without upmix processing However the output file is reformatted as a wav extensible file with a Dolby metadata chunk and upmix is appended to the filename Profile PCM_WAV E 1 gt wav PCM File to NTSC 29 97 Hz Dolby E Encoding Process gt Dolby E Encoding 29 97 Hz WAVE w WAVE PCM SMPTE 337M formatted Dolby E Program Config gt 5 1 2 or 5 1 only Dolby E Profile PCM_WAV E 1 encodes PCM wav files into 29 97 Hz Dolby E The output wav file contains 29 97 Hz Dolby E formatted per SMPTE 337M 20 bit mode Note that the output wav file which contains the 20 bit Dolby E data utilizes 24 bit audio sample words Therefore each 20 bit Dolby E data word is placed in the 20 most significant bits of each wav audio sample word Also note that only source files containing either six or eight channels are support
32. Correction oomcinnnccnnnnncnnnccnccccrnnnncrcnnnnrncnn nn narran 2 Audio Analysis and Correction for Audio Types Without Metadata 0sseeeneeneeeeeeeee 2 MS OIRH Front tia a Ae ea adhe a dt eatery 5 DP600 CD DVD Drive Behind Touch Screen Door nn cnn 5 DP600 Rear Panels cota erat decis latas 8 Connect DP600 Keyboard Front Panel CONNECTION o oooccnncncnnccnnnnccnccncccnnnonancnnrca narco 9 Connect DP600 to Network 9 DP600 Welcome Green 10 E ie Tee EE 11 Enter Gateway Address Number Pad Gcreen cc nana nana ncnns 11 Date amp ergeet tia dia 12 Set Server Date Time Green 12 Select REGION SCCM tie hehavinded coer tebe ie r aaa aaa anaana adele asrini 13 Select City or Zone Green 13 License Agreement Screen concccinnncccnnncconnccncnnnrcc naar n nn r 14 MES A e 14 Select Product Licensing on DolbySupport Home Page cocooccccncccccooccncnacccononancnna conan nnnnaneos 15 Get New License File Page 15 Product Registered Page iii dd 16 Upgrade Serial Number 17 Upgrade Appears Under Previous Upgrades AAA 17 License Confirmation Prompt cnn 18 Finished DEER 19 DP600 Front Panel Home Green 20 System Crea radiata 21 Software Information Screen onncccnnncccnnnccccnnonnnononccnnrrnnn non cnrnnrn crac 21 Upgrade Scribd 22 License Upgrade Screen ococonnccccnncccccnocccononcnnnonc conan cnn 22 CONTI SC iii atte 23 Network Scree Miiri ae iia aan ca 23 Date amp Time Reboot Gcreen tsipena nasaan arai nn nc cnc canon rca 24
33. DO DOLBY Dolby DP600 Program Optimizer Manual Issue 2 Part Number 91963 Dolby Laboratories Inc Corporate Headquarters Dolby Laboratories Inc 100 Potrero Avenue San Francisco CA 94103 4813 USA Telephone 415 558 0200 Fax 415 863 1373 www dolby com European Headquarters Dolby Laboratories Inc Wootton Bassett Wiltshire SN4 8QJ England Telephone 44 1793 842100 Fax 44 1793 842101 DISCLAIMER OF WARRANTIES EQUIPMENT MANUFACTURED BY DOLBY LABORATORIES IS WARRANTED AGAINST DEFECTS IN MATERIALS AND WORKMANSHIP FOR A PERIOD OF ONE YEAR FROM THE DATE OF PURCHASE THERE ARE NO OTHER EXPRESS OR IMPLIED WARRANTIES AND NO WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OR OF NONINFRINGEMENT OF THIRD PARTY RIGHTS INCLUDING BUT NOT LIMITED TO COPYRIGHT AND PATENT RIGHTS LIMITATION OF LIABILITY IT IS UNDERSTOOD AND AGREED THAT DOLBY LABORATORIES LIABILITY WHETHER IN CONTRACT IN TORT UNDER ANY WARRANTY IN NEGLIGENCE OR OTHERWISE SHALL NOT EXCEED THE COST OF REPAIR OR REPLACEMENT OF THE DEFECTIVE COMPONENTS OR ACCUSED INFRINGING DEVICES AND UNDER NO CIRCUMSTANCES SHALL DOLBY LABORATORIES BE LIABLE FOR INCIDENTAL SPECIAL DIRECT INDIRECT OR CONSEQUENTIAL DAMAGES INCLUDING BUT NOT LIMITED TO DAMAGE TO SOFTWARE OR RECORDED AUDIO OR VISUAL MATERIAL COST OF DEFENSE OR LOSS OF USE REVENUE OR PROFIT EVEN IF DOLBY LABORATORIES OR ITS AGENTS HAVE BEEN ADVISED ORALLY OR IN WRITING OF THE POSSI
34. DP6 erial number amp PIN below rive Serial Number 499999 PIN 81479 Insert the flash drive into the DP600 the License button below to install it license Figure 2 23 License Upgrade Screen 22 Dolby DP600 Program Optimizer Manual Starting the System for the First Time Reconfiguring the Network Settings A Caution Before changing the network settings be sure you re connected to a network To reconfigure the network settings 1 Press config in the system a screen The config screen appears as shown in Figure 2 24 ayo i home system config lt gt M Ei network date time touchscreen Figure 2 24 Config Screen 2 Press network in the config screen config The network screen appears where you can reconfigure your network settings as shown in Figure 2 25 This screen is similar to the network screen in Figure 2 4 except for the undo button at the lower left corner The undo button in this screen replaces the cancel button If you press the undo button the system deletes your new entries in this screen only After changing your network settings you are prompted to manually reboot the system A 4 home system config network Hostname required dp600 szm EE 10 201 1 1 gt Interface Disabled undo button Figure 2 25 Network Screen Dolby DP600 Program Optimizer Manual 23 Using the DP600 Reconfiguring the Date amp Time Settin
35. Dolby Digital AC 3 elementary streams contained within a single program transport stream SPTS to Dolby Digital Plus E AC 3 The E AC 3 elementary streams replace the original AC 3 elementary streams but retain the original PID values The dialogue normalization value in the E AC 3 elementary streams is correctly provisioned based on the ITU R BS 1770 speech level All audio metadata is preserved in this profile except for the output data rate which is provisioned as follows For 1 0 mono sources the output data rate is 96 kbps For 2 0 stereo sources the output data rate is 128 kbps For 3 2 or 3 2L sources the output data rate is 224 kbps Profile PS_PCM 1 gt MPEG 2 Program Stream Dolby E Decode to Multiprogram wav Extensible File with Dolby Metadata Chunk Dialnorm Set Correctly Multiprogram WAVE Extensible File PCM w Metadata Chunk dialnorm set correctly Process gt Dolby E decode gt Speech based T MPEG 2 Program Loudness Estimation for all Dolby E programs Stream with Dolby E Measurement Type gt Speech based ITU R BS 1770 Profile PS_PCM 1 decodes all Dolby E streams within an MPEG 2 program stream to a single multiprogram PCM wav extensible file with a Dolby metadata chunk Note that the dialogue normalization value for each program in the audio metadata chunk is set correctly Also note that this profile assumes the MPEG 2 program stream file was generated by an Avid Pinnacle S
36. Dolby Support com Resources for Dolby products Home Get New License File UserForums Indicates a required field Lo Serial Number Product Licensinga ll Applications T Product Registration Product Peo d Product information l n mee El Installed Locationt Software Installed Location2 PE Installed Locations SSS AAA installed City Ap Search DolbySupport Installed State ES bRequestapassword pForaot your password J Log ott i Support Installed Zip A installed Country Choose Country ER Suggestions Dealer Supplier eum My Account Register product Reset form cancel AA Enter required information then click Register product Figure 2 13 Get New License File Page Dolby DP600 Program Optimizer Manual Using the DP600 20 Select DP600 from the Product drop down menu if it is not already selected 21 Enter the required information in the rest of the fields the unit s Serial Number is displayed on the DP600 touch screen as shown in the example in Figure 2 11 22 Fields marked with an asterisk are required After entering information in all the required fields select Register product near the bottom of the page as shown in Figure 2 13 Once the product is registered a message in red text near the top of the screen informs you that the DP600 is now registered and the registered product information appears at the bottom of the screen ident
37. Estimation dialnorm provisioning amp Dolby Metadata chunk generation Measurement Type gt Speech based ITU R BS 1770 WAVE Extensible File PCM w Metadata Chunk Profile PCM_PCM 2 estimates the speech loudness of the wav file and automatically generates a Dolby metadata chunk with the proper dialogue normalization value In addition RF Line Mode compression profiles are set to Film Standard and remaining metadata parameters are set to default values Note that multichannel wav files are supported and are processed as a single program Profile PCM_PCM 3 gt wav PCM File Loudness Normalization to 27 LKFS and Dolby Metadata Chunk Generation WAVE PCM Process gt Speech based Loudness Estimation and Normalize to 27 LKFS amp Dolby Metadata chunk generation Measurement Type gt Speech based ITU R BS 1770 WAVE Extensible File PCM w Metadata Chunk Profile PCM_PCM 3 normalizes the loudness of the file resulting in a long term speech level of 27 LKFS In addition it automatically generates a Dolby metadata chunk with the proper dialogue normalization value and RF Line Mode compression profiles set to Film Standard while the remaining Dolby metadata parameters are set to default values Note that multichannel wav files are supported and are processed as a single program Dolby DP600 Program Optimizer Manual 73 DP600 Program Optimizer Detailed Profile Descriptions Profile P
38. F File with PCM Tracks Only Normalized to 27 LKFS Process gt Speech based Loudness Estimation and normalization to 27 LKFS for GXF File with PCM PCM tracks GXF File with PCM tracks Tracks Only CH normalized to 27 LKFS Measurement Type gt Speech based ITU R BS 1770 Profile GXF_GXF 4 normalizes all PCM audio tracks contained within pairs of GXF tracks media type 18 as defined in Table 5 of SMPTE 360M 2004 resulting in a speech level normalized to 27 LKFS 2 Media type 18 tracks channels are provisioned to handle Dolby E 86 Dolby DP600 Program Optimizer Manual Profile Descriptions Profile GXF_GXF 5 gt GXF File Dolby E dialnorm Correction and PCM Normalization to 27 LKFS Process gt Speech based Loudness Estimation and dialnorm correction Dolby E A S y GXF File with Dolby E ae ee Ga E amp PCM normalized to 27 LKFS MA ancient SES normalized to 27 LKFS Measurement Type gt Speech based ITU R BS 1770 Profile GXF_GXF 5 corrects the dialogue normalization value in all Dolby E programs contained on all GXF audio tracks where the measured dialogue loudness is greater than the original dialogue normalization value by 1 dB All PCM audio tracks contained within pairs of GXF tracks media type 18 as defined in Table 5 of SMPTE 360M 2004 are normalized resulting in a speech level normalized to 27 LKFS Profile GXF_GXF
39. Figure A 13 Work Order Database ooooooconnccconocicnnnccccononcnonononnoncnnn nono nnnnn cara n nn n nan carr nnn nac n nana cnc 37 Work Orders Into Scrims ratas 38 Into Reports Sreem ico an a aaa i 38 Detailed Report Displayed in Reports Info Screen occcciocccinnccccnonccnnnccccnnnnnnnnnn conan nanannccnnns 39 Export Report Confirmation 40 Edit Selected Workorder Green 40 Click Reports in Home Screen cncccccocccnnoccccononcnononccnnnnno non cn rn nnn naar rra 41 Click Info in Home Reports Screen ccccecccceeeeeeeeeeeeeeeaeeeeeeeeecaaaeseeeeeeeseaeeeceeeesecaeeeseeeeeaes 41 Display Report in Home Reports Info Green 42 Red LED Indicates Failed Disk Drive ek 44 Removing the DP600 Drive Cover cococccccccccoccccccconccnoncnconnnnnnnn cnc nonnnnnnnnn cra nn nan nnn cc narra nananccnns 45 Remove the Drive Retaining Bracket AA 45 Physical Drive NUMDEIS uiar r aAA EEL AEE RTE 46 Remove Failed Drive from DPBOD nis reuniitsri en na AR E E a aa R 46 Insert Replacement Drive in DO 47 Reinstall Retaining Bracket sutitan rnae aE SAE AAE EE SSAA 47 Reinstall Front Panel Drive Cover 48 DP600 Front Panel Power Supply Indicator cnn 51 DP600 Failed Power Supply Top Unit in Figure 51 Loosen Thumbscrew on Failed Power Supply 2 cccccceeeeeeeeeeeeeeeeeeeeessaeeeeeeeeessaeeeteneees 52 Press on Tab and Pull Handle to Remove Failed Power Supply c ooooonoccccocccnonocccconccnnananinnno 52 Remove Failed Power Supply neiise nadaanan a
40. S o El sladden som medf ljer denna enhet m ste kopplas enligt foljande Fas Brun Neutral Bla Jord Gro n Gul BELANGRIJK VEILIGHEIDS VOORSCHRIFT Deze unit voldoet aan de EN60950 1 veiligheids standaards Dit apparaat mag niet worden blootgesteld aan vocht Vanwege het risico dat er druppels in het apparaat vallen dient u er geen vloeistoffen in bekers op te plaatsen Voor een veilig gebruik en om het gevaar van electrische schokken en het risico van brand te vermijden dienen de volgende regels in acht te worden genomen o Controleer of de spanningscaroussel op het juiste Voltage staat o Gebruik alleen zekeringen van de aangegeven typen en waarden NL o Aansluiting van de unit alleen aan een geaarde wandcontactdoos o De netkabel die met de unit wordt geleverd moet als volgt worden aangesloten Fase Bruin Nul Blauw Aarde Groen Geel Dolby DP600 Program Optimizer Manual v Table of Contents Chapter 1 Introduction 1 1 1 2 1 3 1 4 1 5 1 6 Work Flow Integration a isa 3 Work Flow Flexibility and Ease Of USC oooccconnnocccccncccoccccccnnnoncnnnonanonnnnnnnnnonnn cnn K ERER 3 APPIICAIONS EE 4 Supported Media Formats and Audio Types oooooccincccnnnoccccncccconcnnnnnnaccnannnnnnnno conan nn nnnnccnns 4 DP6OO Front Panel ia did daa 5 1 5 1 Touch Screen User Interface oooooconicccnnnnninnccccconnnnnncnnncnnrnnn nn nn nn naar rra 5 1 52 CDIDVD DIVE nicas ti a ir ita tadas taa Aaa caia id 5 1 5 3 Syst
41. Verde Giallo AVISO IMPORTANTE DE SEGURIDAD Esta unidad cumple con la norma de seguridad EN60950 1 La unidad no debe ser expuesta a goteos o salpicaduras y no deben colocarse sobre el equipo recipientes con liquidos como tazas de cafe Para asegurarse un funcionamiento seguro y prevenir cualquier posible peligro de descarga o riesgo de incendio se han de observar las siguientes precauciones o Aseg rese que el selector de tensi n est ajustado a la tensi n correcta para su alimentaci n o Aseg rese que los fusibles colocados son del tipo y valor correctos tal como se marca en la unidad E o La unidad debe ser puesta a tierra conect ndola a un conector de red correctamente cableado y puesto a tierra o El cable de red suministrado con esta unidad debe ser cableado como sigue Vivo Marr n Neutro Azul Tierra Verde Amarillo VIKTIGA SAKERHETSATGARDER Denna enhet uppfyller s kerhetsstandard EN60950 1 Enheten far ej uts ttas for yttre verkan samt f rem l innehallande vatska s som kaffemuggar far ej placeras pa utrustningen For att garantera s kerheten och gardera mot eventuell elchock eller brandrisk m ste f ljande observeras o Kontrollera att sp nningsv ljaren r inst lld p korrekt n tsp nning o Konrollera att s kringarna r av r tt typ och f r r tt str mstyrka s som anvisningarna p enheten f reskriver o Enheten m ste vara jordad genom anslutning till ett korrekt kopplat och jordat el uttag c
42. able stitched ac3 File P Dolby Digital AC 3 Program 1 stitched ac3 File Dolby Digital AC 3 Program n Profile WAV E_STITCH_AC3 1 transcodes 5 1 or a 5 1 2 20 bit Dolby E files formatted per SMPTE 337M wrapped in a 24 bit wav file container to ac3 files The encoded output data rates are automatically provisioned as six channel and two channel programs at 384kbps Any two channel PCM programming that is not Dolby E data detected within the source wav file that is within the Dolby E 337M wav is automatically encoded to the ac3 format with an acmod of 2 0 and seamlessly stitched in the proper sequence into the final ac3 file that is along with the 5 1 3 2L ac3 if applicable As a result this profile creates a continuous ac3 file with seamless acmod metadata changes that is 2 0 to 5 1 to 2 0 and so on that correspond to the original source file transitions from two channel PCM to Dolby E and vice versa Note This profile supports 20 bit Dolby E files containing either 5 1 or 5 1 2 Dolby E data and or two channel 24 bit wav PCM files As a result if the system processes a 24 bit 2 channel wav PCM file using this profile it creates a single ac3 file In addition all output files append stitched to the filename Dolby DP600 Program Optimizer Manual 77 DP600 Program Optimizer Detailed Profile Descriptions Profile WAV E_STITCH_AC3 2 gt Adapt
43. ain 16 Dolby DP600 Program Optimizer Manual Starting the System for the First Time DQ Dolby Support com Resources for Dolby products PSUPPORT PDOLBY bRequesta password Forgot your password Home Upgrade Serial Number Homes Serial Number 49886 Product Registration jt a Product Information y ate Pin Number TH Enter PIN Product Licensing Westen IR Enter upgrade key Software Applications Gliek Upgrade Search DolbySupport Support 7 Previous Upgrades Suggestions A Edit My Account E MM Log Off Figure 2 15 Upgrade Serial Number All upgrades appear at the bottom of the screen under Previous Upgrades When you are done click the Done button On the Get License page enter the unit s PIN next to its serial number and click Download to download your new license with all upgrades applied Proceed to step 24 DE Dolby Subport com Resources for Dolby products Home Upgrade Serial Number User Forums Product Registrati on Serial Number 499998 Product Information Product Licensing be Pin Number Sottware Upgrade Key Applications _ _ _ _ Upgrade Search DolbySupport Support e Suggestions Previous Upgrades Edit My Account logon Description DateTime 2008 04 15 14 41 45 027 Upgrade displayed Transcode Figure 2 16 Upgrade Appears Under Previous Upgrades Dolby DP600 Prog
44. ains how to maintain the Dolby DP600 The sections that follow show you how to diagnose and repair hard drives and power supplies 3 1 Maintaining the DP600 Hard Drives The DP600 has five physical internal hard drives Drives 1 and 2 are arranged in a RAID 1 configuration to provide protection for the operating system as well as local storage The remaining three hard drives are configured as separate drives to provide local storage This configuration of one RAID pair and three separate drives represents four logical drives There are four bicolor LEDs on the front panel labeled 1 2 3 and 4 These LEDs indicate the status of the DP600 s four logical internal hard drives The drive LEDs function as follows e Off nonilluminated Indicates a functional drive with no current disk access activity e Green Indicates normal drive activity e Red Indicates a drive failure LED 1 shows the status of the two drive RAID 1 configuration The operating system is installed on these mirrored drives to prevent a physical drive failure resulting in an inoperable system If either of the mirrored drives fails the other RAID drive enables the system to operate normally until the failed drive is replaced LEDs 2 3 and 4 indicate the status of the other three physical disks These disks are configured as separate drives and do not have RAID backup capability If any of these drives fail the failed drives must be replaced and any work orders in progre
45. al AC 3 Program 1 WAVE w 8 SMPTE 337M gt Measurement Type gt Speech based formatted Dolby E ITU R BS 1770 E L Dialnorm Metadata Correction 4 24 bit WAVE Extensible File w SMPTE 337M 340M formatted Dolby Digital AC 3 Program n Profile WAV E_WAV AC3 2 encodes a Dolby E file formatted per SMPTE 337M wrapped in a wav file container to a single or multiple wav extensible files containing Dolby Digital AC 3 data formatted per SMPTE 337M 340M The output Dolby Digital data contained in the 24 bit wav extensible files also contains the correct dialogue normalization value indicated for each program Encoded output data rates are automatically provisioned at either 384 kbps for six channel audio or 192 kbps for two channel audio All remaining metadata parameters follow the AC 3 metadata for each program contained in the Dolby E data file stream Note that only files containing either 5 1 or 5 1 2 Dolby E data are supported by this profile Profile WAV E_WAV E 1 gt Dolby E 337M wav Loudness Correct and Reencode i Process gt Dolby E Loudness Correction WAVE w via Metadata dialnorm WAVE w SMPTE 337M o gt SMPTE 337M formatted Dolby E Measurement Type gt Speech based formatted Dolby E ITU R BS 1770 Profile WAV E_WAV E 1 performs Dolby loudness correction on a 20 bit Dolby E file formatted per SMPTE 337M wrapped in a 24 bit wav file container The dialogue normalization
46. as installed at cable and IPTV head ends need to have their content normalized before it is made available to the public This content can be supplied to the servers either directly via an ingest department at the broadcaster or affiliate or via satellite from one or more content aggregators The DP600 can be installed at the content aggregator normalizing content before it is sent pitched over the satellite link Alternatively it can be installed at the head end taking content that has either been ingested directly or caught from one or more pitchers and normalizing it before it is passed to the customer facing server 1 2 Work Flow Flexibility and Ease of Use The Dolby DP600 platform suits several types of applications including archiving automated quality control content conversion and media asset management and it offers considerable potential for integration with third party systems through an open application programming interface API You can control the DP600 and its processing engines in three ways to suit specific user requirements e Manual control Users can set up and initiate work orders on an individual or batch basis from a simple to use interface e Third party control via Web services To enable system integration at any level the DP600 s processing engines are also available as a set of Web services This allows manufacturers to integrate these engines directly into their work flow to create a seamless user
47. as shown in Figure 3 14 Figure 3 14 Install New Power Supply Dolby DP600 Program Optimizer Manual 53 System Maintenance 5 Tighten the thumbscrew by turning it clockwise and reconnect power as shown in Figure 3 15 The replacement unit s LED turns green and the front panel s red LED turns off to verify that the new unit is functioning correctly Tighten thumbscrew and reconnect power Figure 3 15 New Power Supply Installed and AC Cable Reconnected 54 Dolby DP600 Program Optimizer Manual Upgrading Installing the DP600 Software 3 3 Upgrading Installing the DP600 Software The DP600 packing kit includes an installation DVD With this disc you can perform a clean installation or an upgrade of the DP600 software if required A clean installation restores the DP600 to the factory settings An upgrade simply updates the software to the latest release retaining all your custom settings To perform an upgrade or a clean installation of the DP600 software 1 Obtain the DP600 DVD from Dolby and be sure the provided keyboard is connected to one of the unit s USB ports Insert the DVD in the CD DVD drive and reboot the system A message says that the software is already installed and displays the currently installed version and the version on the DVD It prompts you to either type y to upgrade or press any key to start a clean installation Press y to upgrade or press any key to start a clean installation
48. atan eaa naar nro 53 Install New Power Supply ccccccceceeeeeeeeeeeeecaeeeeaeeeseeaeeeeeaeeecaeeeseaeesecaeeeseaaeeeeeeeeesaeseeeees 53 New Power Supply Installed and AC Cable Reconnected oooooooccccnococcccccononnnncconannnoncnnnnnnnos 54 Calibration Setup Gcreen neenu nenn nnenn nnen nenn nent 55 Add Workorder CON iia reco tit 58 Enter Path SCreen eege chides sshaeceduastaaate Anais bis S 59 Type URL in Enter Path Screen cocooncccconccccnnocccnonocononnnnnannncnnnnnnnn nn c cnn ca nnnn cnn mcr nn nana 59 URL Entered in Add Workorder Green 60 Glick BTOWS Osuna dada idos ti ias 60 Select Protocol Green 60 Enter User Credentials Gcreen cnn no cnn nac nnnnn rn rra 61 Enter Server Details Green 61 Select File SCreen tadas idas al ill 62 Greate BookMark minisari aaia aSa aa aa aa aaa iaa Dans ba 63 Add Bookmark Screen EE 63 Selecting a Bookmark AA 64 Bookmark Entered in Source Field 64 Dolby DP600 Program Optimizer Manual Chapter Introduction Welcome to Dolby file based audio The Dolby DP600 Program Optimizer is a direct result of Dolby Laboratories continued leadership in the development of innovative broadcast technologies This innovative tool is designed specifically for cable satellite IPTV and terrestrial TV broadcasters that employ a file based infrastructure and work flow The DP600 includes the world s first intelligent audio analysis and automated loudness normalization engine for ma
49. based Loudness Estimation and dialnorm correction Dolby E 8 Layer II normalized to 27 LKFS ER MPEG 2 Program MPEG 2 Program Stream with Dolby E Stream with Dolby E 8 dialnorm correct amp MPEG 1 Layer II MPEG 1 Layer II Measurement Type gt Speech based ITU R normalized to 27 LKFS BS 1770 Profile PS_PS 2 corrects the dialogue normalization value within all Dolby E elementary streams if the measured dialogue loudness is greater than the original dialogue normalization value by 1 dB In addition it normalizes all MPEG 1 LII elementary streams resulting in a speech level of 27 LKFS Note that any PCM data found in the Dolby E elementary stream is normalized to 27 LKFS Also note that this profile assumes the MPEG 2 program stream file was generated by an Avid Pinnacle Systems MediaStream system Profile GXF_GXF 1 gt GXF File Dolby E dialnorm Correction Process gt Speech based Loudness Estimation and Dolby E dialnorm correction GXF File with Dolby E SC E eh gt dialnorm correct Measurement Type gt Speech based ITU R PCM Tracks Unchanged BS 1770 N q Profile GXF_GXF 1 corrects the dialogue normalization value in all Dolby E programs contained on all General eXchange Format GXF SMPTE 360M audio tracks when the measured dialogue loudness is greater than the original dialogue normalization value by 1 dB Dolby DP600 Program Optimizer
50. d in a wav file container to a wav extensible PCM file The output wav file also contains a Dolby metadata chunk Note that the AC 3 decoder operating mode is Line mode with scale factors set to 1 0 Dolby DP600 Program Optimizer Manual 75 DP600 Program Optimizer Detailed Profile Descriptions Profile WAV EC3_PCM 1 gt Dolby Digital Plus 337M 340M Formatted wav to wav Extensible PCM with Metadata Chunk WAVE File w SMPTE 337 M 340 M Process gt Dolby Digital Plus E AC 3 to PCM WAYE Bienio File formatted gt f S EE PCM Dolby Digital Plus BAGS Deserier Opereing O w Metadata Chunk L E AC 3 Profile WAV EC3_PCM 1 decodes a Dolby Digital Plus E AC 3 file formatted per SMPTE 337M 340M wrapped in a wav file container to a wav extensible PCM file The output way file also contains a Dolby metadata chunk Note that the E AC 3 decoder operating mode is Line mode with scale factors set to 1 0 Profile WAV E_PCM 1 gt Dolby E 337M Formatted wav to wav Extensible PCM with Metadata Chunk WAVE Extensible File 1 PCM w Metadata Chunk Program 1 WAVE w SMPTE 337M gt Measurement Type gt Speech based formatted Dolby E ITU R BS 1770 3 Dialnorm Metadata Correction only WAVE Extensible File n PCM w Metadata Chunk Program n Process gt Dolby E to PCM Profile WAV E_PCM 1 decodes a Dolby E file formatted per SMPTE 337M wrapped ina wav fi
51. d keyboard are connected to the DP600 then reconnect the power Press lt Alt gt lt 3 gt when prompted to access the 3ware BIOS Manager At this point a red dialog box informs you that a degraded disk array is installed Press any key to continue If you replaced one of the RAID drives physical drives 1 or 2 e Use the arrow keys on the keyboard to select highlight the available drive then press the space bar to select it e Use the arrow keys to select the RAID marked as degraded then press the space bar to select it e Press the lt Tab gt key to select Maintain Unit then press lt Enter gt e Use the arrow keys to select Rebuild in the pop up menu then press lt Enter gt A list appears that shows which RAID drive is designated for rebuilding e Press lt Enter gt to select OK e Press lt F8 gt then type Y to accept your entries and allow the unit to reboot Note On some smaller keyboards you may need to press lt F Lock gt to enable the lt F8 gt function for the dual use keys If you are rebuilding only the RAID array and did not replace a RAID drive e Use the arrow keys on the keyboard to highlight the RAID marked as degraded then press the space bar to select it e Press the lt Tab gt key to select Maintain Unit then press lt Enter gt e Use the arrow keys to select Rebuild in the pop up menu then press lt Enter gt A list appears that shows which RAID drive is designated for r
52. e front panel flashes red see Figure 3 9 and a warning alarm sounds The Dolby catalog number for each of your DP600 s power supplies is identified by a label affixed to the right side of each unit Failed power supply red LED Figure 3 9 DP600 Front Panel Power Supply Indicator To replace a DP600 power supply 1 Identify the failed unit in the rear panel by its nonilluminated LED as shown in the example in Figure 3 10 Figure 3 10 DP600 Failed Power Supply Top Unit in Figure Dolby DP600 Program Optimizer Manual 51 System Maintenance 2 Press the red Power Supply Alarm Reset button to turn off the warning alarm then disconnect the power cable on the failed power supply and loosen the unit s thumbscrew by turning it counterclockwise as shown in Figure 3 11 Disconnect power and loosen thumbscrew Press Alarm Reset button Figure 3 11 Loosen Thumbscrew on Failed Power Supply 3 Press the failed power supply s tab to the left while grasping its handle and pulling the unit out of its slot see Figure 3 12 and Figure 3 13 Press tab to the left Pull handle Figure 3 12 Press on Tab and Pull Handle to Remove Failed Power Supply 52 Dolby DP600 Program Optimizer Manual Replacing a DP600 Power Supply Figure 3 13 Remove Failed Power Supply 4 Position the replacement unit squarely within its slot and push it along the guiding surface until it snaps into place
53. e you ll notice a new User Forums button Clicking here will open a new Dolby Support internet presence in your browser that will allow you to ask and answer questions post application ideas and communicate and share ideas with your fellow users of Dolby products and technologies as well as Dolby specialists Please take a moment to open the new Dolby User Forums and register an account to begin participating Product Information Includes manuals quick start guides product photos specifications and other information License Information Get License file for DP600 Products Software Current versions of software for Dolby professional products Applications Information on using Dolby products and or technologies Got Upgrade Cable There are two ways to upgrade your Dolby professional product The simplest is through the front panel 8 pin mini DIN port that connects to the standard PC serial RS 232 or COM port This requires a special cable a 9 pin D Sub for the computer to 8 pin mini DIN Otherwise you can use the rear panel D n remote with an RS 485 interface and appropriate cabling Click here for more information or to request an upgrade cable Miscellaneous Tips Currently includes instructions on determining the current software version for various products Figure 2 12 Select Product Licensing on DolbySupport Home Page The Get New License File page appears as shown in Figure 2 13 DQ
54. ebuilding e Press lt Enter gt to select OK e Press lt F8 gt then type Y to accept your entries and reboot the unit Depending on the original size of the RAID array a rebuild will take from one to several hours to complete During this time the system operates normally If you replaced a single non RAID drive physical drives 3 4 or 5 e Use the arrow keys to highlight the new drive that appears in the Available Drives area then press the space bar to select it e Press the lt Tab gt key to move to the menu buttons at the bottom of the screen then use the arrow keys to select the Create Unit button and press lt Enter gt The available unit should now appear in the Create a disk array from these drives box e Use the arrow keys to select the OK button then press lt Enter gt Dolby DP600 Program Optimizer Manual ES System Maintenance e Type Y to enable the write cache on the new drive The 3ware BIOS Manager main screen reappears e Press lt F8 gt to exit then type Y to accept your entries and reboot the unit When you replace a single drive no rebuild time is required The new drive appears immediately 50 Dolby DP600 Program Optimizer Manual Replacing a DP600 Power Supply 3 2 Replacing a DP600 Power Supply The DP600 requires only one power supply a second unit is provided for backup If a problem occurs with either of these redundant power supplies the power failure indicator LED on th
55. ed As a result a two channel source file generates an error condition and is not processed Profile PCM_WAV E 2 gt wav PCM File to NTSC 25 Hz Dolby E Encoding Process gt Dolby E Encoding 25Hz WAVE w WAVE PCM SMPTE 337M formatted Dolby E Program Config gt 5 1 2 or 5 1 only Dolby E Profile PCM_WAV E 2 encodes PCM wav files into 25 Hz Dolby E The output wav file contains 25 Hz Dolby E formatted per SMPTE 337M 20 bit mode Note that the output wav file which contains the 20 bit Dolby E data utilizes 24 bit audio sample words Therefore each 20 bit Dolby E data word is placed in the 20 most significant bits of each wav audio sample word Note that only source files containing either six or eight channels are supported As a result a two channel source file generates an error condition and is not processed 74 Dolby DP600 Program Optimizer Manual Profile Descriptions Profile PCM_WAV E 3 gt wav PCM File to NTSC 23 98 Hz Dolby E Encoding Process gt Dolby E Encoding 23 98Hz WAVE w WAVE PCM gt SMPTE 337M formatted Dolby E Program Config gt 5 1 2 or 5 1 only Dolby E Profile PCM_WAV E 3 encodes PCM wav files into 23 98 Hz Dolby E The output wav file contains 25 Hz Dolby E formatted per SMPTE 337M 20 bit mode Note that the output wav file which contains the 20 bit Dolby E data utilizes 24 bit audio sample words Therefore each 20 bit Dolby E data
56. either 192 kbps for six channel audio or 96 kbps for two channel audio All E AC 3 metadata parameters are provisioned from the AC 3 metadata within each program contained in the Dolby E data file stream Note that only files containing 5 1 or 5 1 2 Dolby E data are supported Profile TS_TS 1 gt MPEG 2 Transport Stream AC 3 Loudness Correction Process gt Gpeech based Loudness MPEG 2 Transport Estimation and dialnorm correction MPEG 2 Transport Stream with AC 3 Stream with AC 3 Measurement Type gt Speech based ITU R BS 1770 Profile TS_TS 1 corrects the loudness within all AC 3 elementary streams contained within the MPEG 2 transport stream file This process corrects the metadata values dialnorn dynrng and compr within the original AC 3 elementary streams if the measured dialogue loudness is greater than the original dialogue normalization value within 1 dB If the measured dialogue loudness is below 32 LKFS the audio is scaled resulting in an average dialogue loudness of 31 LKFS with dialogue normalization set to 31 All remaining metadata is preserved 82 Dolby DP600 Program Optimizer Manual Profile Descriptions Profile TS_TS 2 gt MPEG 2 Transport Stream MPEG 1 LII Loudness Normalization and Dolby Digital AC 3 dialnorm Correction MPEG 2 Transport Process Speech based Loudness Normalization to 24 LKFS MPEG 2 Transport i Stream with Dolby ita layer NAND Stream wi
57. em Reset and Display Controls oooononinicccnnonicanncccconnncnnnanccnnan canon cnn rnnnnn nn 6 1 5 4 Power Supply Indicators cccccecescececeeeeeeeeeeceeeeeeseaeesecaeeeseaaeeeeeeeeesaeeseceeeesenaeessaes 6 1 5 5 Internal Drive Indicators oooomccccnnnsccccnnnnnsccnnnnnancccnnnnnnnnccnnnnnnneccn nn nnnnncnnnnnnnnes 6 15 60 USB2 0 Poltica til di ts 7 DESOO Bearbenel it ti 8 Chapter 2 Using the DP600 2 1 2 2 2 3 2 4 Installing the DP600 Hardware 9 Starting the System for the First Time ooooncccnnccinccccnonccnnnccncnnnrccnn acc nn rca rca 10 2 2 1 DP600 Home Green 20 2 2 2 Using the System Screen concincccinocccnnonccnononcncnnccnn anna 21 Using the DP600 Remote Client Goftware 27 2 3 1 Understanding Work Orders sssssssssseessessiesrirssiisssrrssitnsstnnstnnnnnnntnnnennnttnnnennnt 27 2 3 2 Running the DP600 Client oococcccnnnccccnccccnnnocnncnnccnnnnncnnonc conan cnn rca 29 2 3 3 DP600 Client Home Green 30 Greating a Work Order ccoo ii EEN 31 Chapter 3 System Maintenance 3 1 3 2 3 3 Maintaining the DP600 Hard Drives 0 eee ceeeceeeeeeee eee eeeeeaeeeeeeeeeaeeeeeeeeaaeeeeeeeeaaeeeeeeeaaees 43 3 1 1 Replacing a Drives contenant ia 44 S42 Rebuilding Driven aiii a Rie eae doit 49 Replacing a DP600 Power Supply oocooccccccocccnnncccccnonncnononnncnncnnnannnnnnn cn naar nn nn ca nana nan 51 Upgrading Installing the DP600 Software oooooocccnnncccnncoccnonccccnonncnnnancccono cnn
58. es the output data rate is 160 kbps For 3 2 or 3 2L sources the output data rate is 224 kbps Profile AC3_PCM 1 gt Dolby Digital AC 3 to wav Extensible PCM with Metadata Chunk f Process gt Dolby Digital AC 3 to PCM WAV Extensible File AC 3 Decoder Operating Mode Line w Metadata Chunk ac3 file Profile AC3_PCM 1 decodes an ac3 Dolby Digital file to a wav extensible file The output file also contains a Dolby metadata chunk Note that the AC 3 decoder operating mode is Line mode with scale factors set to 1 0 Profile AC3_PCM 2 gt Dolby Digital AC 3 to wav Extensible PCM with Metadata Chunk 3 fil Process gt Dolby Digital AC 3 to PCM WAV Extensible File E AC 3 Decoder Operating Mode Custom no Metadata applied w Metadata Chunk Profile AC3_PCM 2 decodes an ac3 Dolby Digital file to a wav extensible file The output file also contains a Dolby metadata chunk Note The AC 3 decoder operating mode is Custom that is no metadata applied 70 Dolby DP600 Program Optimizer Manual Profile Descriptions Profile EC3_PCM 1 gt Dolby Digital Plus E AC 3 to wav Extensible PCM with Metadata Chunk Process gt Dolby Digital Plus E AC 3 to PCM WAV Extensible File w Metadata Chunk e callo E AC 3 Decoder Operating Mode Line Profile E
59. ess correction e Pay per view PPV file analysis and loudness correction e Pay per view file audio transcoding Terrestrial Broadcast Applications e Automated broadcast media file quality control and loudness correction e Automated broadcast media file transcoding 1 4 Supported Media Formats and Audio Types The DP600 supports many media formats and audio types including media file formats and linear and coded audio types Media File Formats GXF SMPTE 360M MPEG 2 program stream MPEG 2 transport stream Linear Audio Types wav BWF and multichannel wav files with or without a Dolby audio metadata chunk at 16 20 and 24 bit PCM within any of the listed media file formats above Coded Audio Types Dolby E Dolby Digital AC 3 Dolby Digital Plus E AC 3 MPEG 1 LII 4 Dolby DP600 Program Optimizer Manual DP600 Front Panel 1 5 DP600 Front Panel The DP600 front panel includes the following components e Touch screen user interface e CD DVD drive and system reset and display controls behind touch screen door e Power supply indicators e Local storage indicators e USB 2 0 port Touch screen user intertace Power supply indicators Figure 1 3 1 5 1 1 5 2 EI DO DoLBY USB 2 0 port L Local storage indicators DP600 Front Panel Touch Screen User Interface The LCD touch screen provides user controls for rescheduling cancelling and
60. figure your work orders In addition a Notes field appears below the work order fields where you can enter some related text for a specific work order Standard al immediately O O Figure 2 35 Add Workorder Screen To set up your work order 1 Click the Name field then enter a name for your work order 2 Click the Type field then select the type of work order you d like to run Standard Pinnacle Standard Hot Folder Pinnacle Hot Folder or Grass Valley Hot Folder Standard v Pinnacle Hot Folder Grass Valley Hot Folder Figure 2 36 Selecting a Work Order Type 32 Dolby DP600 Program Optimizer Manual Creating a Work Order 3 Click the Source field The Enter Path screen appears as shown in Figure 2 37 In this screen you can enter the path to the file or folder for a hot folder that you want to designate for processing Before entering a path be sure you re connected to an active network and then set up a shared folder for all authorized users as described in Setting Up a Shared Folder on page 57 Note Supported file system protocols include FTP SAMBA CIFS and SFTP You can enter a path using any of the following methods e Enter a URL directly Type the desired URL in the URL field You must pre encode your URL entry which cannot include the username password domain information in the URL field For example smb dp600 users common hot_folder If necessa
61. gram Optimizer Manual iii Regulatory Notices WEEE 9 To avoid exposure to dangerous voltages and to avoid damage to the unit do not connect the rear panel Ethernet port to telephone circuits 10 As the colours of the cores in the mains lead may not correspond with the coloured markings identifying the terminals in your plug proceed as follows e The green and yellow core must be connected to the terminal in the plug identified by the letter E or by the earth symbol _L or coloured green or green and yellow e The blue core must be connected to the terminal marked with the letter N or coloured black e The brown core must be connected to the terminal marked with the letter L or coloured red 11 This apparatus must be earthed PRODUCT END OF LIFE INFORMATION This product was designed and built by Dolby Laboratories to provide many years of service and is backed by our commitment to provide high quality support When it eventually reaches the end of its serviceable life it should be disposed of in accordance with local or national legislation For current information please visit our website at www dolby com environment Dolby DP600 Program Optimizer Manual Regulatory Notices IMPORTANT SAFETY NOTICE This unit complies with safety standard EN60950 1 as appropriate The unit shall not be exposed to dripping or splashing and no objects filled with liquids such as coffee cups shall be placed on the equipment To
62. gs To reconfigure the date amp time settings 1 Press config in the system a screen The config screen appears as shown in Figure 2 24 In this screen you can reconfigure your date amp time settings if required 2 Press date amp time in the config screen A prompt appears that informs you that the system will automatically reboot and return to the commissioning application as shown in Figure 2 26 To set the date amp time the i into the commissioning app Continue o cancel ok Figure 2 26 Date amp Time Reboot Screen 3 Press ok to return to the commissioning application and page through the screens until you display the date amp time settings This screen is similar to the date amp time screen in Figure 2 6 4 Change the date and time settings then page through the screens and press the finish button The system automatically reboots with your new settings 24 Dolby DP600 Program Optimizer Manual Starting the System for the First Time Recalibrating the Touch screen Your DP600 touch screen was calibrated during the manufacturing process but occasionally you may need to perform a recalibration To recalibrate the touch screen o system 1 Press config in the system screen config The config screen appears as shown in Figure 2 24 In this screen you can recalibrate the touch screen if required 2 Press touchscreen MMM in the config screen The calibrate
63. gure 2 47 Export Report Confirmation When a work order is running and you press or click this icon the work order pauses To resume processing click or press this icon again pause When you select a work order in the database and then press or click this icon the Edit Selected Workorder screen appears as shown in Figure 2 48 In this screen you can edit your work order settings After making the desired changes you can either select update to update the current work order or select create new to create a new work order If you create a new work order we recommend entering a new name to differentiate it from the original work order The new work order now appears in the work order database E Eih rk order ou ample 2 Standard v TS_TS 1 smb fmediastorel eng dp600 content eyear TEST1S_AC3_DN_20 mpg Pworkorder_example Sep 6 2007 9 30 00 AM O cancel create new update Figure 2 48 Edit Selected Workorder Screen When you click this icon the Add Workorder screen appears as shown in Figure 2 35 In this menu you can set up your work orders as described on page 31 One of these icons is displayed depending on the state of the selected work order If the selected work order is running or scheduled the cancel icon appears and you can press or click this icon to cancel the selected work order If the selected work order is not scheduled or running the delete icon appears and you can delete the w
64. he End At field Hot Folder Grass Valley Hot Folder Figure 2 39 Hot Folder and Grass Valley Hot Folder Options Pinnacle Hot Folder Options are the same as Hot Folder Options Grass Valley Hot Folder Shows Additional Options 34 Dolby DP600 Program Optimizer Manual Creating a Work Order If you want to specify a time when the DP600 stops looking for files to process in this hot folder click the End At field The End At screen appears as shown in Figure 2 40 9 Use the up and down arrows to specify a day month year and time when you want to end the hot folder work order then click ok Figure 2 40 Entering the Work Order End Time For Hot Folders amp Grass Valley Hot Folders Only The next two Add Workorder fields for all types of hot folders are defined as follows e Stable Period The Stable Period parameter allows you to fine tune the hot folder work order activation process for your specific network environment This applies to configurations where the system copies files from one server into a hot folder the DP600 is monitoring on another server This is typical in work flow environments that process an extremely large number of files In this type of work flow some remote file systems cannot confirm to any degree of accuracy when a file is completely copied from its source into a hot folder By utilizing the Stable Period parameter the DP600 periodical
65. heck the system status reconfigure the network and date and time upgrade your license and reboot and shut down the system Checking the System Status To check the system status 1 Press system ROM at the upper right side of the home screen system The system screen appears as shown in Figure 2 20 Grayed out icons are currently nonfunctional a EY home system di O status config upgrade power Figure 2 20 System Screen 2 Press status El in the system screen The Software Information screen appears as shown in Figure 2 21 Figure 2 21 Software Information Screen Dolby DP600 Program Optimizer Manual 21 Using the DP600 Upgrading Your License To upgrade your license from a DP600 to a DP600 C to allow encoding decoding transcoding upmixing and other additional functionality use the touch screen as follows 1 Press upgrade in the system a screen The upgrade screen appears as shown in Figure 2 22 Currently you can upgrade only your license from this screen but not the DP600 software alo i home system upgrade MN software license Figure 2 22 Upgrade Screen The License Upgrade screen appears as shown in Figure 2 23 This screen looks similar to the License screen in Figure 2 11 that you used to set up your system for the first time You follow the same procedure to upgrade your system abols i home system upgrade license dolbysupportcom he unit Enter the
66. ified by serial number and as shown in Figure 2 14 DG Dolby Support com Resources for Dolby products Thome Get New License File User Forums Indicates a required field Product Registered Successfully Product Registration Product DP600 z i S Applicati Programmer E Product Information geg Ee A Serial Number 49998 R WE Licensing Installed Location 1000 Brannan Street Tsottware Installed Location2 Pa Installed Location3 T Cris A Installed City San Francisco EM Search DolbySupport installed State a Support Installed Zip 94103 R installed Country United States ER Suggestions Dealer Supplier Edit My Account Register product Reset form cancel Log Off Registered Serial Numbers Click on the download link to download license file Product DP600 E Serial Number Pin Number Download Upgrade 499998 GE Download Upgrade Enter PIN E Click Upgrade lick Download to upgrade license to download license Figure 2 14 Product Registered Page 23 To download a license and or upgrade the unit e To download a license type the unit s PIN in the field next to the serial number the PIN is displayed on the DP600 touch screen as shown in the example in Figure 2 11 then click Download Proceed to step 24 e To upgrade the unit click Upgrade The Upgrade Serial Number page appears as shown in Figure 2 14 Enter the unit s PIN and upgrade key and click Upgrade ag
67. ive PCM Dolby E 337M wav to Dolby Digital ac3 WAVE w SMPTE 337M formatted Dolby E and or 2 channel PCM Process gt Dolby E and or 2 channel PCM to seamless Dolby Digital AC 3 with 2 0 lt gt 3 2L metadata transitions if applicable stitched ac3 File Dolby Digital AC 3 p WAVE Profile WAV E_STITCH_AC3 2 transcodes a 5 1 16 bit Dolby E file formatted per SMPTE 337M wrapped in a 16 bit wav file container to an ac3 file The encoded output data rate is automatically provisioned to 384 kbps Any two channel PCM programming that is not Dolby E data detected within the source wav file that is within the Dolby E 337M wav is also automatically encoded to the ac3 format with an acmod of 2 0 and seamlessly stitched in the proper sequence into the final ac3 file that is along with the 5 1 3 2L ac3 if applicable As a result this profile creates a continuous ac3 file with seamless acmod metadata changes that is 2 0 to 5 1 to 2 0 and so on that correspond to the original source file transitions from two channel PCM to Dolby E and vice versa Note This profile supports only 16 bit Dolby E files containing 5 1 Dolby E data and or two channel 16 bit wav PCM files In addition all output files append stitched to the filename Profile WAV E_WAV AC3 1 gt Dolby E 337M Formatted wav to Dolby Digital AC 3 16 Bit 337M 340M Formatted wav 16 bit WAVE Exte
68. le container to a single or multiple wav extensible PCM files The output wav files also contain a Dolby metadata chunk with the correct dialogue normalization value indicated for each program 76 Dolby DP600 Program Optimizer Manual Profile Descriptions Profile WAV E_PCM 2 gt Dolby E 337M Formatted wav to wav Extensible PCM with Metadata Chunk WAVE w SMPTE 337M L gt formatted Dolby E Process gt Dolby E decode gt Speech based Loudness Estimation and dialnorm correction for all Dolby E programs Measurement Type gt Speech based ITU R BS 1770 Multiprogram al Extensible File PCM w Metadata Chunk dialnorm set correctly Profile WAV E_PCM 2 decodes a Dolby E file formatted per SMPTE 337M wrapped ina wav file container to a single wav extensible PCM file The output wav file also contains a Dolby metadata chunk with the correct dialogue normalization value indicated for each program Note that the output file may contain single or multiple programs depending on the configuration of the Dolby E file from which it was generated Profile WAV E_STITCH_AC3 1 gt Adaptive PCM Dolby E 337M wav to Dolby Digital ac3 WAVE w SMPTE 337M formatted Dolby E and or 2 channel PCM WAVE i Process gt Dolby E and or 2 channel PCM to seamless Dolby Digital AC 3 with 2 0 lt gt 3 2L metadata transitions if applic
69. ly checks the size of all new files in the hot folder and waits until the file size stabilizes does not increase in size If the file size doesn t change for the number of milliseconds ms you enter in the Stable Period field then the DP600 activates the work order process on the respective files The default is 20 000 ms This is a safeguard to be sure the system doesn t begin processing files before they re completely copied into the designated hot folder e Scan Interval The Scan Interval specifies how often the DP600 scans a hot folder for new files to process The default is 5 000 ms 10 If applicable enter the desired number of milliseconds in the Stable Period field 11 Enter the desired number of milliseconds in the Scan Interval field if appropriate for your application 12 For Grass Valley hot folders enter the IP Address and IP Port of the Destination folder 13 Click the Profile field The Profile menu displays a list of work order profiles Use the up and down arrows to scroll through the list When you click a profile a short description of the selected profile appears for example transcode a Dolby Digital file to a Dolby Digital Plus file Dolby DP600 Program Optimizer Manual 35 Using the DP600 Profiles that perform loudness correction require a standard DP600 while profiles that perform encoding decoding and or transcoding require the enhanced DP600 C Note For detailed descriptions of all
70. mple depths unless noted otherwise except for Dolby E decoding which defaults to 24 bit sample depths 5 Unless otherwise noted many files processed by the DP600 that is the output files contain the text string corrected which is appended to the input file name For example a source file name such as DP600_test mpg results in a processed file named DP600_test corrected mpg in your destination directory 1 The Dolby metadata chunk specification is available upon request Dolby DP600 Program Optimizer Manual 67 DP600 Program Optimizer Detailed Profile Descriptions 6 Profiles that are capable of processing source files into multiple output files for example a 5 1 2 channel Dolby E decode name each program as follows Program 1 source_filename sequence 1 program 1 corrected wav Program 2 source_filename sequence 1 program 2 corrected wav Note The corrected suffix appears if a loudness correction step was performed 10 All profiles referencing MPEG 2 transport streams assume that only a single program is present For wav files larger than 4 GB the DP600 supports only the European Broadcasting Union EBU RF64 BWF compatible multichannel file format An RF64 format file may also be termed as a Multichannel Broadcast WAV Format or MBWE file All 20 bit Dolby E data must be formatted per SMPTE 337M and wrapped in a 24 bit wav file container before transferring it to the DP600 for proce
71. nanacananinonaninananonononananos 6 POWER sec ese AERA ERRER 6 POWer SUPPLY iconos 6 AAA A R 6 Dolby DP600 Program Optimizer Manual 91 Index license O 26 downloadi gneisses sarisini riniti 16 registering product een 15 lee iip onite eera 16 22 satellite applications oconccncononcnnononcnnononrrncerrncarnoos 4 linear audio epes 4 A A a sai 13 local storage indicators serial POLE dee 8 front panel imei iita arica cris 5 shared folder loudness analysis 3 setting UP dll 57 media file formats ooocnocnoncnconanonnnonnnnnnnonanaronnnnnnorno 4 sh tdoWwi a ia 26 monitor POT E enconenconcnnnnoncnnnnononannnonononannnnnrnonannarannrannannos 8 software netmaskKiiiusand liliana 12 Informatica 21 Network settings EEN 10 sta iii ci iia cra 55 date and M asnes reses e aE canos 12 er 55 DACP iii 12 standard work order gateway addresg en 11 described nica 27 general configuration ociciononionononnnnnconionanenens 11 selec ips 32 OSAMA sia eas Bok wis 11 status ALE Ve ob 3s soina nn int EES TER CITES ETS POET 12 CI io iia 21 license nai sn 14 system NEtM ASK cua aras 12 rebooting sia nne senenta inmi iaai 26 AA aan 23 EE 10 19 e E 13 Shutting doWN siese snini aei ii 26 be TE 13 Stats aa 21 leet 12 UP SLAC rinitis 22 path system reset button sossen nnen eeeeceneseseanenenenees 6 rn ele ciate eatin esl alana cen 58 system screen add bookmark 63 MISTING indian ios idad 21 26 DLO WSIS viaria AE alii 60 temperature desbnagbopt Ze
72. nano cc nano na nana cnnnns 55 Appendix A Setting Up a Shared Folder and Entering a Path A 1 A 2 A 3 A 4 Setting Up a Shared Folder ooooocoonnccconncccnnonccnnnccccononnno nn cnrn rca n arrancan 57 Entering a WEE 58 Entering a Source Path ocoocccinnccconnccconnoccnconcccnncnnnnann cnn non cnn aoaaa a a Aaea ranma nera GAES 58 A 3 1 Entering a URL to Specify a Pat 59 A 3 2 Browsing to a Location to Specify a Path 60 A 3 3 Selecting a Bookmark to Specify a Path 64 Entering a Destination Pat 65 Dolby DP600 Program Optimizer Manual vii Table of Contents Appendix B DP600 Program Optimizer Detailed Profile Descriptions B 1 Understanding DP600 Profiles AA 67 B 2 Profile DESCriptions nenoro ponei aner ae Sede eee ded 69 91 Dolby DP600 Program Optimizer Manual viii Figure 1 1 Figure 1 2 Figure 1 3 Figure 1 4 Figure 1 5 Figure 2 1 Figure 2 2 Figure 2 3 Figure 2 4 Figure 2 5 Figure 2 6 Figure 2 7 Figure 2 8 Figure 2 9 Figure 2 10 Figure 2 11 Figure 2 12 Figure 2 13 Figure 2 14 Figure 2 15 Figure 2 16 Figure 2 17 Figure 2 18 Figure 2 19 Figure 2 20 Figure 2 21 Figure 2 22 Figure 2 23 Figure 2 24 Figure 2 25 Figure 2 26 Figure 2 27 Figure 2 28 Figure 2 29 Figure 2 30 Figure 2 31 Figure 2 32 Figure 2 33 Figure 2 34 Figure 2 35 Figure 2 36 Figure 2 37 Figure 2 38 Figure 2 39 Figure 2 40 Figure 2 41 Figure 2 42 List of Figures Coded Audio with Metadata Analysis and
73. ness of 24 LKFS in the output file Profile TS_TS 4 gt MPEG 2 Transport Stream with MPEG 1 LII Loudness Normalization and Transcoding to AC 3 with the Correct dialnorm Value Process gt Speech based Loudness T Normalization to 24 LKFS for LII amp MPEG 2 Transport MPEG 2 Transport Transcode to Dolby Digital AC 3 with Stream with MPEG 1 Stream with a single gt Correct Dialnorm value Layer Il amp AC 3 MPEG 1 Layer II ES AC 3 stream_type 0x81 Measurement Type gt Speech based AC 3 PID 0x1e2 ITU R BS 1770 Profile TS_TS 4 normalizes the loudness of a single MPEG 1 LII elementary stream contained within the MPEG 2 transport stream file This process scales the loudness resulting in a dialogue loudness of 24 LKFS in the output file The MPEG 1 LII audio is also transcoded to Dolby Digital AC 3 and remuxed witha stream_type value of 0x81 and a PID value of 0x1e2 Dolby DP600 Program Optimizer Manual 83 DP600 Program Optimizer Detailed Profile Descriptions Profile TS_TS 5 gt MPEG 2 Transport Stream with Dolby Digital AC 3 Transcode to Dolby Digital Plus E AC 3 Process gt Speech based Loudness Estimation dialnorm provisioning A MPEG 2 Transport Transcode to Dolby Digital AC 3 with sech Stream with Dolby Correct Dialnorm value ee Digital AC 3 y 219 Measurement Type gt Speech based ITU R BS 1770 Profile TS_TS 5 transcodes all
74. ng is a description of each of these icons When you select a work order in the database and then press or click this icon profile schedule and reports information appears in the info screen as shown in Figure 2 44 In addition if you press or click the reports icon in the info screen the corresponding report information appears for the selected work order as shown in Figure 2 45 This screen displays the following information for each work order e Date e Severity e Description e Name of work order DP600 E A H SS i Ry Eaa home work orders info Profile TS TS 1 MPI Source pausa S om BS Destination Stat Submitted Scheduled Start Scheduled End T delete Click reports to display info shown in Figure 2 45 reports workorder 1 of 3 _ Figure 2 44 Work Orders Info Screen cu pP600 ER e SES a P EI ee home work orders info reports export reports 1 6 of 6 _ Figure 2 45 Info Reports Screen 38 Dolby DP600 Program Optimizer Manual Creating a Work Order On the right side of the reports screen five icons appear When you click any of these icons the reports screen responds accordingly as described below When you press or click on a work order report to select it and then press or a click this icon the corresponding detailed report appears as shown in the info example in Figure 2 46 home work orders info reports Workord
75. nsible File w SMPTE 337M 340M WAVE w Process gt Dolby E to Dolby Digital AC 3 formatted Dolby Digital AC 3 Program 1 SMPTE 337M formatted Dolby E gt Measurement Type gt Speech based ITU R BS 1770 Dialnorm Metadata Correction 16 bit WAVE Extensible File w SMPTE 337M 340M 78 formatted Dolby Digital AC 3 Program n Profile WAV E_WAV AC3 1 encodes a Dolby E file formatted per SMPTE 337M wrapped in a wav file container to single or multiple wav extensible files containing Dolby Digital AC 3 data formatted per SMPTE 337M 340M The output Dolby Digital data contained in the 16 bit wav extensible files also contains the correct dialogue normalization value indicated for each program Encoded output data rates are automatically provisioned at either 384 kbps for six channel audio or 192 kbps for two channel audio All remaining metadata parameters follow the AC 3 metadata for each program contained in the Dolby E data file stream Note that this profile supports only files containing either 5 1 or 5 1 2 Dolby E data Dolby DP600 Program Optimizer Manual Profile Descriptions Profile WAV E_WAV AC3 2 gt Dolby E 337M Formatted wav to Dolby Digital AC 3 24 bit 337M 340M Formatted wav 24 bit WAVE Extensible File w SMPTE 337M 340M formatted Dolby Digital AC 3 Process gt Dolby E to Dolby Digit
76. ny of the most common broadcast media file and audio formats in use today In addition it offers Dolby E Dolby Digital and Dolby Digital Plus encoding decoding and transcoding all in an open architecture Using the DP600 broadcasters can provide their viewers with a consistent audio experience and reduce loudness complaints across all of their programs channels and networks Expanding upon the unique Dialogue Intelligence technology developed for the Dolby LM100 Broadcast Loudness Meter the DP600 normalizes the loudness of audio programs with no impact on their original dynamic range The DP600 automates previously lengthy quality control processes and performs them in faster than real time It automatically analyzes audio bitstreams coded in Dolby E Dolby Digital and Dolby Digital Plus for any channel configuration and loudness level It intelligently and automatically sets validates and corrects the dialogue normalization dialnorm audio metadata parameter without the need for decoding and reencoding ensuring a properly encoded bitstream The DP600 also provides intelligent and automatic speech based loudness normalization for both PCM audio and MPEG 1 LII audio For compressed audio formats that include metadata for example Dolby E Dolby Digital and Dolby Digital Plus the Dolby DP600 can automatically set or correct the dialnorm parameter see Figure 1 1 For audio formats that do not include metadata the Dolby DP600
77. ork order from the database In either case a prompt appears which asks you to confirm your action cancel or delete Select ok or cancel at the confirmation prompt 40 Dolby DP600 Program Optimizer Manual Creating a Work Order Displaying Work Order Reports from the Home Screen In addition to displaying work order reports from the work order database you can also access reports from the home screen To access a report from the home screen 1 Press or click the reports icon in the home screen as shown in Click reports oS Queue Length 1 Workorders OO work orders Figure 2 49 Click Reports in Home Screen The home reports screen appears as shown in Severity Description Workorder Qa Click info Loudness Estimation Log ing w lt MPEC remux Log ingestF export mmary Dolby Digital Decode Log ing Figure 2 50 Click Info in Home Reports Screen Dolby DP600 Program Optimizer Manual A Using the DP600 2 Press or click the desired work order report then click info The respective work order report appears as shown in Figure 2 51 Lo DP600 A home reports Workorder Summa 10 07 Sep 2007 channel mode INF INFO INFO INF INFO INFO IN INFO INFO report 10 of 12 Figure 2 51 Display Report in Home Reports Info Screen export 42 Dolby DP600 Program Optimizer Manual Chapter 3 System Maintenance This chapter expl
78. ot want to reboot the DP600 Ga cancel Figure 2 30 Reboot DP600 Confirmation Prompt 26 Dolby DP600 Program Optimizer Manual Using the DP600 Remote Client Software 3 Press ok at the prompt to reboot or shut down the system If pressing the reboot button does not work you can press lt Cntrl gt lt Alt gt lt Delete gt on the provided keyboard When you shutdown the Dolby DP600 Program Optimizer screen appears When you see this screen disconnect the power cable to shut down completely Caution Currently the front panel touch screen may not display the local home screen following a system restart while remote clients continue to display correctly In such a case reboot the system again to display the local home screen 2 3 Using the DP600 Remote Client Software To process audio using the DP600 you need to use the Dolby DP600 Remote Client software also referred to as DP600 Client or Client With this application you can define and run an operation we call a work order The DP600 Client runs on your Microsoft Windows PC This application looks similar to the front panel touch screen but provides more user control functions For example with the Client you can e Add and configure work orders e Run work order profiles to analyze dialogue levels perform dialogue normalization and encode transcode decode audio files e Export work order reports 2 3 1 Understanding Work Orders
79. ou re using DHCP the IP address does not appear until you complete the system setup Note In this screen and in all the following DP600 setup screens you enter information to configure your system If you press the cancel button at the bottom left corner of any of the following setup screens the system cancels all of your entries in all the setup screens in addition to the currently displayed setup screen A cancel confirm prompt appears If you confirm the unit cancels your entries and automatically reboots and then the Welcome screen reappears At this point you can reenter your settings 10 Dolby DP600 Program Optimizer Manual Starting the System for the First Time ECUECTICNN dp 600 stein Use DHCP E IP Ad Interface Disabled O arm gt cancel finish Figure 2 4 Network Screen 2 Be sure the provided USB keyboard is connected to one of the DP600 USB ports You can connect the keyboard to any free USB port front or rear panel but we recommend using one of the rear panel USB ports because the front panel is more convenient for inserting a USB flash drive which is required to load a license In the General Configuration box press the Hostname field then use the keyboard to enter a host name Currently you must use the keyboard to make entries in the Hostname field Enter a unique name with no spaces or other nonconventional network naming characters for example dp600 unit 1 In
80. p DOLBY I Z o lt gt E fer Dolby and the double D symbol are registered trademarks of Dolby Laboratories e o o Power supplies Ge Active Ethernet port upper port USB 2 0 ports port upper port Figure 1 5 DP600 Rear Panel 8 Dolby DP600 Program Optimizer Manual Chapter 2 Using the DP600 2 1 Installing the DP600 Hardware To install the Dolby DP600 1 Connect the provided USB keyboard to the DP600 front panel USB port or one of the rear panel USB ports DO Dorey Connect provided USB keyboard here or in rear panel Figure 2 1 Connect DP600 Keyboard Front Panel connection 2 Connect one end of the provided Ethernet cable to the upper Ethernet port port 0 on the DP600 rear panel 3 Connect the other end of the provided Ethernet cable to your network Caution Currently you must use the DP600 s upper Ethernet port to connect to your network The lower Ethernet port is currently nonfunctional 4 Connect both power supplies to a power source using the provided power cables E e i E o o el O CG BY l
81. pausing work orders and reports and checking the system status You simply touch the icon that represents the desired function and the DP600 responds accordingly To add and configure work orders and export reports you need to use the DP600 Client For a complete description of all work order functions see Understanding Work Orders on page 27 CD DVD Drive The CD DVD drive is located behind the touch screen door With this drive you can perform DP600 software upgrades System Reset and Display buttons CD DVD drive SS Figure 1 4 DP600 CD DVD Drive Behind Touch Screen Door Note You cannot play commercial CDs or DVDs in the DP600 CD DVD drive Dolby DP600 Program Optimizer Manual 5 Introduction 1 5 3 System Reset and Display Controls These recessed buttons are located behind the touch screen above the CD DVD drive If you need to press any of these buttons use a nonconductive material such as a toothpick If you press the System Reset button the system restarts Press this recessed button only if you cannot restart the system using the DP600 software or by pressing lt Ctrl gt lt Alt gt lt Delete gt to restart as described on page 26 Always avoid restarting by disconnecting and reconnecting the power cables You can use the Display control button to adjust the LCD display 1 5 4 Power Supply Indicators Three power supply LEDs on the front panel indicate whether the power is on if one of
82. place a DP600 hard drive 1 Look at the front panel drive LEDs then refer to Table 3 1 to determine which drive has failed Failed drive red LED Figure 3 1 Red LED Indicates Failed Disk Drive 44 Dolby DP600 Program Optimizer Manual Maintaining the DP600 Hard Drives 2 Remove the DP600 front panel drive cover by placing one hand on its left side and one hand on its right side then pulling it toward you until it disengages from the main unit as shown in Figure 3 2 Figure 3 2 Removing the DP600 Drive Cover 3 Use a Phillips screwdriver to loosen the four screws that secure the drive retaining bracket then remove the bracket as shown in Figure 3 3 bracket A Caution When loosening the screws be sure not to remove them completely from the Figure 3 3 Remove the Drive Retaining Bracket Dolby DP600 Program Optimizer Manual 45 System Maintenance Starting from the left side of the drive cage the first slot contains physical drive 1 RAID drive 1 The second slot contains physical drive 2 RAID drive 2 Starting with the third slot physical drives 3 4 and 5 are installed next in that order In this example RAID drive 1 is the failed drive that requires replacement Figure 3 4 shows how the drives are numbered from left to right numbers do not appear on the actual unit Figure 3 4 Physical Drive Numbers 4 Match the failed drive s number determined in step
83. press Cancel to reboot O ET O cancel finish Figure 2 18 Finished Screen 28 Press finish The DP600 setup is now completed and the system automatically reboots During the reboot process remove any discs in the CD DVD drive as the system attempts to boot from any inserted disc If an installation disc is inserted the system begins a new installation Dolby DP600 Program Optimizer Manual WG Using the DP600 2 2 1 DP600 Home Screen After you complete the DP600 setup the unit automatically reboots and the DP600 home screen appears as shown in Figure 2 19 This screen displays the date and time at the upper right corner The system status in the right column shows icons indicating the current status of the server network net and disk s A green happy face indicates all is OK A red unhappy face indicates a problem If you see an unhappy face touch the corresponding icon to display additional information The work orders and reports icons also appear in the home screen You ll learn how to use the work order and report functions later in this chapter as described in Understanding Work Orders on page 27 i home oe Queue Length 0 Workorders ei OH work orders reports system Figure 2 19 DP600 Front Panel Home Screen 20 Dolby DP600 Program Optimizer Manual Starting the System for the First Time 2 2 2 Using the System Screen The system screen allows you to c
84. ram Optimizer Manual 17 Using the DP600 You can repeat the previous steps for each license you want to download and each upgrade you want to apply to your license Note After you apply your system upgrade keys future downloads do not require reentering the keys After entering your PIN click Download and your license automatically downloads including all applicable upgrade keys 24 At the prompt save the downloaded file to the USB flash memory stick that you previously inserted into the PC you are using to view this Web page This file is the license for your DP600 system including any upgrades 25 Remove the flash memory stick from the PC then insert it into one of the DP600 USB ports It will take a few seconds for the DP600 to recognizes the license 26 Press the license button in the License screen A confirmation prompt informs you that the license installed successfully Note If the system does not install the license press the license button again The system may take a few seconds to recognize the inserted flash drive containing the license file License installe y Please remove the flash drive ok Figure 2 17 License Confirmation Prompt 27 Press ok The Finished screen appears 18 Dolby DP600 Program Optimizer Manual Starting the System for the First Time Congratulations Your settings are readyto be saved Pr Fini elow t e your settings and reboot the DP600 or
85. rear side of the cover engages the hole in the front of the unit If you replaced one RAID drive and did not shut down the system the RAID array rebuilds automatically However if you are not running multiple work orders we recommend shutting down the system rebooting and manually rebuilding the RAID array as described in Rebuilding a Drive on page 49 If you replaced a non RAID drive rebooting and manual rebuilding is required as described in Rebuilding a Drive on page 49 If you replaced both RAID drives drives 1 and 2 you need to use the DP600 software DVD to reinstall the software as described in Upgrading Installing the DP600 Software on page 55 In such a case you perform a clean installation and the system automatically synchronizes the two RAID drives recreating the original mirrored RAID array manual rebuilding not required 48 Dolby DP600 Program Optimizer Manual Maintaining the DP600 Hard Drives 3 1 2 Rebuilding a Drive To rebuild a DP600 hard drive 1 Z Place the DP600 in an idle state by halting all work orders being processed Determine which physical hard drive has failed 1 2 3 4 or 5 by checking the drive LEDs on the DP600 front panel as described in Maintaining the DP600 Hard Drives on page 43 Shut down the unit by clicking the power button in the system screen then remove the failed drive from its slot following the instructions in Replacing a Drive on page 44 Be sure a monitor an
86. rive RAID 1 configuration The operating system is installed on these mirrored drives to prevent a physical drive failure resulting in an inoperable system If either of the mirrored drives fails the other RAID drive enables the system to operate normally until the failed drive is replaced Dolby DP600 Program Optimizer Manual DP600 Front Panel LEDs 2 3 and 4 indicate the status of the other three physical disks These disks are configured as separate drives and do not have RAID backup capability If any of these drives fail the failed drives must be replaced and any work orders in progress during the failure must be restarted If one of the drive LEDs turns red refer to Table 1 1 to determine which physical drive failed Typically the DP600 automatically rebuilds the RAID array when one of the RAID drives has a problem or is replaced with the power on During the RAID rebuild process LED 1 blinks in red in half second intervals When the rebuild process is complete LED 1 stops blinking In some instances you must initiate the rebuild process manually as described in Rebuilding a Drive on page 49 For example if you replace a non RAID drive If you replace both RAID drives you also need to reinstall the DP600 software In such a case follow the instructions for a clean installation in Upgrading Installing the DP600 Software on page 55 When you reinstall the software the system automatically synchronizes the two RAID
87. rk 1 Click the Bookmarks field in the Enter Path screen All the bookmarks you previously added in the Select File screen appear in the Choose a bookmark drop down menu 2 Select the desired bookmark in the drop down menu to specify a path then click ok as shown in Figure A 12 ue DP500_Hot_Folder on mercury v e Choose a bookmark sername Domain SMB only Figure A 12 Selecting a Bookmark The selected bookmark s path appears in the Source field in the Add Workorder screen as shown in the example in Figure A 13 smb mercury users common ams DP600_Hot_Folder Immediately Indefinitely Figure A 13 Bookmark Entered in Source Field 64 Dolby DP600 Program Optimizer Manual Entering a Destination Path A 4 Entering a Destination Path To enter a Destination path 1 Click the Destination field in the Add Workorder screen The Enter Path screen appears This screen is identical to the Enter Path screen shown in Figure A 2 2 Use any of the methods described for entering a source path to enter the destination path then click ok see Entering a Source Path on page 58 Dolby DP600 Program Optimizer Manual 65 Appendix B DP600 Program Optimizer Detailed Profile Descriptions B 1 Understanding DP600 Profiles A DP600 profile defines a set of actions and processes on a specific type of source file which includes specific actions on any or all audio data type
88. rosystem s Java Web Start launches the Client automatically connects to the DP600 and the DP600 Client home screen appears as shown in Figure 2 32 Subsequently you can start the Client with either the shortcut described above or by revisiting the DP600 Web page and following the links again If the Client PC does not have the correct version of the Java Runtime Environment JRE installed and the Client PC has access to the Internet the correct version of Java installs automatically If this fails then you need to install the JRE manually by clicking the icon on the splash screen or going to www java com en download manual jsp locale en amp host www java com You can download a copy of the DP600 manual this manual by clicking the icon If the current version of Client software is not already installed on the Client PC the correct version automatically downloads directly from the DP600 no Internet access required You can install and run the Client from multiple computers simultaneously Client updates automatically occur each time the Client runs on a specific PC For this reason the Client isn t really installed as such You simply run the application from the DP600 which automatically downloads any necessary files and updates as required Dolby DP600 Program Optimizer Manual 29 Using the DP600 2 3 3 DP600 Client Home Screen After launching the DP600 Client as described in Running the DP600 Client on page 2
89. rovisioned to handle Dolby E Dolby DP600 Program Optimizer Manual 87 DP600 Program Optimizer Detailed Profile Descriptions Profile GXF_GXF 8 gt GXF File with Discrete 5 1 Channel PCM Normalization to 27 LKFS and or Correct dialnorm Metadata in VANC GXF File with a discrete 5 1 channel PCM gt program on pairs 1 3 Process gt Speech based Loudness Estimation and normalization to 27 LKFS for 5 1 program ONLY on pairs 1 3 AND OR correct dialnorm metadata value in VANC gt Measurement Type gt Speech based ITU R BS 1770 GXF File with a 5 1 PCM program normalized to 27 LKFS AND OR correct dialnorm metadata value in VANC Profile GXF_GXF 8 normalizes a discrete 5 1 channel PCM program contained in the GXF file resulting in a speech level normalized to 27 LKFS and or dialogue normalization correction contained within audio metadata carried in the vertical ancillary space VANC Note that tracks 1 6 pairs 1 3 are treated as a single 5 1 program Any remaining audio tracks are not processed but are retained in their original format in the output file Profile GXF_PCM 1 gt GXF File with Dolby E to Multiprogram wav Extensible File with Dolby Metadata Chunk Containing the Correct dialnorm Value GXF File with Dolby E gt Process gt Dolby E decode gt Speech based Loudness Estimation for all Dolby E programs amp Dolby Metadata chunk generation
90. ry you can enter a Username Password and Domain SMB only in the corresponding fields below After entering the URL click ok e Browse to the desired location Click browse to display the Select Protocol screen if the URL field is blank and select either Windows Share SMB or FTP or SFTP then click the right arrow and if necessary enter a Username Password and Domain SMB only in the Enter User Credentials screen Click the right arrow and enter a path in the Enter Server Details screen Then click finish to display the Select File screen click on the desired file or folder then click ok If you want to create a bookmark click on the desired file or folder in the Select File screen click add then click ok If you click browse and the URL field is not blank the system attempts to browse to the entered URL e Select a bookmark Click on the Bookmarks field to display all the bookmarks you previously added in the Select File screen as described previously then select the desired bookmark to specify the path and click ok When you select a bookmark it automatically appears in the URL field If necessary you must still enter a Username Password and Domain SMB only in the corresponding fields each time you select the bookmark After selecting the bookmark you can click browse to go to the corresponding location Note For complete details on entering a path using the above three methods see Entering a Path on page 58
91. s for two channel audio All remaining metadata parameters follow the AC 3 metadata for each program contained in the Dolby E data file stream Note that only files containing either 5 1 or 5 1 2 Dolby E data are supported Profile WAV E_AC3 2 gt Dolby E 337M Formatted wav to Dolby Digital AC 3 File AC 3 dialnorm Value Automatically Provisioned to the Correct Value ac3 File gt Dolby Digital AC 3 Program 1 Process gt Dolby E to Dolby Digital AC 3 WAVE w Measurement Type gt Speech based S SMPTE 337M gt formatted Dolby E MUAR ESU Dialnorm Metadata Correction only 7 ac3 File gt Dolby Digital AC 3 Program n Profile WAV E_AC3 2 transcodes a 5 1 or a 5 1 2 Dolby E stream file formatted per SMPTE 337M wrapped in a wav file container to ac3 files Encoded output data rates are automatically provisioned at either 384 kbps for six channel audio or 192 kbps for two channel audio The dialogue normalization value is also automatically provisioned to the correct value for all AC 3 programs contained in the Dolby E stream All remaining AC 3 metadata parameters are provisioned from the AC 3 metadata within each program contained in the Dolby E data file stream Note that only files containing either 5 1 or 5 1 2 Dolby E data are supported 80 Dolby DP600 Program Optimizer Manual Profile Descriptions Profile WAV E_AC3 3 gt Dolby E 337M Formatted
92. s providing a checklist of things you need before you can reconfigure your system as shown in Figure 2 3 Follow the instructions in Starting the System for the First Time on page 10 to reconfigure your system Press target Figure 3 16 Calibration Setup Screen Dolby DP600 Program Optimizer Manual 55 Appendix A Setting Up a Shared Folder and Entering a Path A 1 Setting Up a Shared Folder For source and destination work order directories you need to set up a shared folder for all authorized users The following instructions provide a high level example for creating a shared folder on a Microsoft Windows PC with a static IP address and testing the Dolby DP600 Client application Create a login account on the Windows PC named dp600 Create a folder in the root of your hard drive named dp600share Copy content files into dp600share Right click on the dp600share folder then select Sharing and Security Select the Share this folder button Click the Permissions button Click the Add button Be sure the Location is the local computer Enter dp600 in the text field Click the Check Names button to verify that the account exists on your system Click the OK button Be sure the permissions for the added user is set to Full Control Click the OK button Select the Security tab at the top of the window Click the Add button Be sure the Location is the local computer Enter dp600 in the text field Click the
93. s and the configurations contained within them if applicable Following are some important points to remember regarding DP600 profiles Note DP600 profile information is updated periodically For the latest information on DP600 profiles please go to the DP600 area on www dolbysupport com 1 The DP600 profiles and processes always expect and are capable of providing multichannel wav files that are restricted to the following channel order within the file Left Right Center LFE Left Surround Right Surround per SMPTE 320M Table 2 Failure to adhere to this rule results in unintended behavior 2 All DP600 profiles and processes that expect and or provide multichannel or multiprogram audio must be contained in a single file that is all channels are interleaved For this reason the DP600 does not support discrete mono input files that together comprise a complete multichannel audio program 3 For any DP600 profiles that expect a PCM wav source file the Dolby metadata chunk is optional In cases where the metadata chunk is not present the DP600 processes utilize a default set of metadata parameters except where noted in the profile descriptions provided on the following pages in this appendix For this reason the Dolby metadata chunk is required to obtain full control over any all Dolby metadata parameters on a file by file basis 4 All decoder related profiles that output PCM wav files default to 16 bit sa
94. s designed specifically for Pinnacle MediaStream server files Grass Valley Hot Folder Work Order This type of hot folder is designed specifically for Grass Valley Profile and Profile XP server files Work Order Profile While the type of work order indicates how the DP600 accesses audio files the work order profile controls the processing specifications for example whether the DP600 performs audio loudness analysis and correction transcoding encoding decoding or other actions on the respective audio files 28 Dolby DP600 Program Optimizer Manual Using the DP600 Remote Client Software 2 3 2 Running the DP600 Client To run the Client 1 Open your browser and go to http lt dp600 server gt where lt dp600 server gt is the host name or IP address of the DP600 for example http zico eng or http 10 201 1 88 After you open the Client for the first time a shortcut appears on your desktop and in the Start gt All Programs gt Dolby Laboratories menu Currently we support Windows XP using Internet Explorer versions 6 and 7 Firefox 2 and Opera 9 Other browsers and operating systems are untested or unsupported The DP600 Program Optimizer splash screen appears as shown in Figure 2 31 DP600 Program Optimizer A Download manual launch Download Java client Click launch client Figure 2 31 DP600 Program Optimizer Splash Screen 2 Click launch client in the splash screen Sun Mic
95. screen The Enter User Credentials screen appears as shown in the example in Figure A 7 for a Windows Share SMB path Username Domain O aw Figure A 7 Enter User Credentials Screen finish 3 Enter a Username Password and Domain SMB only in the Enter User Credentials screen then click the right arrow at the bottom of the screen The Enter Server Details screen appears 4 Enter a path in the Enter Server Details screen as shown in the example in Figure A 8 for a Windows Share SMB path then click finish d SUN mercury users common ams Figure A 8 Enter Server Details Screen Dolby DP600 Program Optimizer Manual 6l Setting Up a Shared Folder and Entering a Path The Select File screen appears as shown in the example in Figure A 9 for a Windows Share SMB path In this screen you can select the file or folder you want to specify as the path to your source files You can also bookmark a path by clicking add bookmark remove an existing bookmark by clicking remove bookmark move up one level in the file hierarchy by clicking up directory refresh the displayed path by clicking refresh and connect to another server by clicking server connect Add bookmark path add bookmark Folder M Remove bookmark path remove bookmark up directory Move up one level Refresh path Connect to another canes server connect Figure A 9 Select File Screen 5 Click
96. ss during the failure must be restarted If one of the drive LEDs turns red refer to Table 3 1 to determine which physical drive failed Typically the DP600 automatically rebuilds the RAID array when one of the RAID drives has a problem or is replaced with the power on During the RAID rebuild process LED 1 blinks in red in half second intervals When the rebuild process is complete LED 1 stops blinking In some instances you must initiate the rebuild process manually as described in Rebuilding a Drive on page 49 For example if you replace a non RAID drive If you replace both RAID drives you also need to reinstall the DP600 software In such a case follow the instructions for a clean installation in Upgrading Installing the DP600 Software on page 55 When you reinstall the software the system automatically synchronizes the two RAID drives recreating the original mirrored RAID array manual rebuild not required To replace a drive follow the instructions in Replacing a Drive on page 44 Dolby DP600 Program Optimizer Manual 43 System Maintenance Table 3 1 shows the LED conditions that specify the failed drive Table 3 1 Local Storage LED Conditions Front Panel LED Condition Failed Physical Drive 1 Solid red 1 1 Blinks in red in 2 two second intervals 1 Blinks in red in Rebuilding RAID half second intervals 2 Solid red 3 3 Solid red 4 Solid red 5 3 1 1 Replacing a Drive To re
97. ssing this excludes any Dolby E data contained within an MPEG transport stream MPEG program stream or GXF file All 16 bit Dolby E data must be formatted per SMPTE 337M and wrapped in a 16 bit wav file container before transferring it to the DP600 for processing this excludes any Dolby E data contained within an MPEG transport stream MPEG program stream or GXF file Note 16 bit Dolby E data is supported only when used with specific profiles For more information see the profile descriptions in Section B 2 68 Dolby DP600 Program Optimizer Manual Profile Descriptions B 2 Profile Descriptions Following are descriptions of all the current DP600 profiles Profiles that perform encoding decoding and transcoding functions require the DP600 C Note DP600 profiles are updated periodically For the latest DP600 profiles please go to the DP600 area on www dolbysupport com Profile AC3_AC3 1 gt Dolby Digital AC 3 Speech Based Loudness Correction via Metadata Process gt Loudness estimate A correction ac3 file ac3 file Measurement type gt Speech based ITU R BS 1770 Profile AC3_AC3 1 corrects the metadata values dialnorm dynrng and compr within the ac3 file if the measured dialogue loudness is greater than the original dialogue normalization value by 1 dB Profile AC3_AC3 2 gt Dolby Digital 2 0 to 5 1 adaptive Upmix with Loudness Correction Process gt Upmix 2
98. tal Plus E AC 3 Note that the E AC 3 encoder acmod value is configured through the nchannel s field in the wav format chunk or the acmod field within the Dolby metadata chunk if present Encoded output data rates are adaptively provisioned as follows six channel 192 kbps and two channel 96 kbps All remaining metadata parameters are set to default values or provisioned through the Dolby metadata chunk if present Profile PCM_MPll 1 gt wav PCM to MPEG 1 LII Encoding WAVE f gt Process gt PCM to MPEG 1 Layer Il gt mp2 PCM Profile PCM_MPII 1 encodes PCM wav files to MPEG 1 LII Only mono and stereo audio sources are accepted 72 Dolby DP600 Program Optimizer Manual Profile Descriptions Profile PCM_PCM 1 gt wav PCM File Speech Based Loudness Normalization to 27 LKFS WAVE 1 KN PCM Process gt Speech based Loudness Estimation and Normalize to 27 LKFS Measurement Type gt Speech based ITU R BS 1770 WAVE Extensible File PCM w Metadata Chunk Profile PCM_PCM 1 normalizes the loudness of the file resulting in a long term speech level of 27 LKFS Note that multichannel wav files are supported and are processed as a single program and remaining metadata parameters are set to default values Profile PCM_PCM 2 gt wav PCM File Loudness Estimation and Dolby Metadata Chunk Generation WAVE PCM Process gt Speech based Loudness
99. th To Enter a URL 1 In the Enter Path screen type the desired URL in the URL field If required you can enter a Username Password and Domain SMB only in the corresponding fields as shown in Figure A 3 Note Supported file system protocols include FTP SAMBA CIES and SFTP SS Choose a bookmark v Da smb mercury users common ams DP600_Hot_Folder ers ES OO SS ES do lbynet O cancel ok Figure A 3 Type URL in Enter Path Screen 2 After entering a URL click ok Your URL appears in the Source field in the Add Workorder screen as shown in the example in Figure A 4 for a Windows Share SMB path Dolby DP600 Program Optimizer Manual 59 Setting Up a Shared Folder and Entering a Path MER Hot Folder As mb mercury users common ams DP600_Hot_Folder Immediately Indefinitely 20000 5000 Figure A 4 URL Entered in Add Workorder Screen A 3 2 Browsing to a Location to Specify a Path To browse to a location 1 Click browse in the Enter Path screen as shown in Figure A 5 Bookmarks URL Click browse Figure A 5 Click Browse The Select Protocol screen appears as shown in Figure A 6 Windows Share SMB FTP or SFTP finish Figure A 6 Select Protocol Screen 60 Dolby DP600 Program Optimizer Manual Entering a Source Path 2 Select either Windows Share SMB or FTP or SFTP then click the right arrow at the bottom of the
100. th Dolby Digital AC 3 amp Digital AC 3 amp MPEG Layer l Measurement Type gt Speech based ITU R BS 1770 MPEG lla Dialnorm Correction for Dolby Digital AC 3 Profile TS_TS 2 normalizes the loudness of all MPEG 1 LII elementary streams contained within the MPEG 2 transport stream file This process scales the loudness resulting in a dialogue loudness in the output file of 24 LKFS This profile also corrects the loudness of all AC 3 elementary streams contained within the file This process corrects the metadata values dialnorm dynrng and compr within the original AC 3 elementary streams if the measured dialogue loudness is greater than the original dialogue normalization value within 1 dB If the measured dialogue loudness is below 32 LKFS the audio is scaled resulting in an the average dialogue loudness of 31 LKFS with dialogue normalization set to 31 All remaining metadata is preserved Profile TS_TS 3 gt MPEG 2 Transport Stream MPEG 1 Layer Il Loudness Normalization Process gt Gpeech based Loudness MPEG 2 Transport Normalization to 24 LKFS MPEG 2 Transport Stream with MPEG 1 rn gt Stream with MPEG 1 Layer II Measurement Type gt Speech based Layer Il ITU R BS 1770 Profile TS_TS 3 normalizes the loudness of all MPEG 1 LII elementary streams contained within the MPEG 2 transport stream file This process scales the loudness resulting in a dialogue loud
101. the DP600 profiles see Appendix B In addition check the DP600 area of www dolbysupport com for periodic profile updates Figure 2 41 Selecting a Work Order Profile 36 Dolby DP600 Program Optimizer Manual Creating a Work Order 14 Select the work order profile you want to use to process your files then click ok After you add a work order it runs as specified in the Add Workorder menu When a work order is running the home screen displays the progress as shown in LAJ home work orders om om E Figure 2 42 Work Order Running as Displayed in Home Screen After you add a work order it appears in the work order screen database when you select work orders in the home screen The work order database displays the names profiles creation dates status scheduled start times and source files for all work orders as shown in For hot folder work orders a folder icon appears on the left side of each entry home work orders Profile Created Status Schd Start Source File FINISHED M FINISHED pause delete CSS workorders 1 3 of 3 _ Figure 2 43 Work Order Database Dolby DP600 Program Optimizer Manual 37 Using the DP600 In addition to adding work orders and displaying work order information the work order screen also displays additional icons which enable you to display additional information and pause edit cancel and delete a selected work order Followi
102. the General Configuration box press on the Gateway field The Enter Gateway Address number pad appears as shown in Figure 2 5 10 201 0 1 e 1 2 3 Figure 2 5 Enter Gateway Address Number Pad Screen Dolby DP600 Program Optimizer Manual D Using the DP600 A DI Press on the desired numbers to enter an optional gateway address then select ok In the Upper Interface Settings box press the Use DHCP box if it is unchecked for dynamic addressing or uncheck this box by pressing on it if you want to enter a fixed IP address The upper interface corresponds to the top Ethernet port port 0 on the DP600 rear panel The lower interface bottom port is currently nonfunctional If you specified a fixed IP address the respective fields are now active Make your entries by pressing on the IP Address and Netmask fields to display the corresponding number pad screens then press on the appropriate numbers see gateway address number pad instructions above Alternatively you can press on the field and then use the USB keyboard to make your entries as described earlier for the Hostname field Press the right arrow at bottom of the Network screen The Date amp Time screen appears as shown in Figure 2 6 RA GC MT 08 00 US Pacific Pacific Standard Time O O ETIP cancel finish Figure 2 6 Date amp Time Screen 9 Press the Server Date amp Time field The Set Server Date Time screen appears as sho
103. thin the Dolby metadata chunk if present Encoded output data rates are adaptively provisioned to either six channels at either 384 kbps for six channel audio or 192 kbps for two channel audio All remaining metadata parameters are set to default values or provisioned through the Dolby metadata chunk if present 7i Dolby DP600 Program Optimizer Manual DP600 Program Optimizer Detailed Profile Descriptions Profile PCM_DOWNMIX gt Multichannel PCM wav Dolby Pro Logic Il Downmix WAVE Process gt 5 0 or 5 1 ProLogic Il Encoding downmix WAV Extensible File PCM NOTE 2 channel sources are passed through w Metadata Chunk Profile PCM_DOWNMIX encodes five or six channel 3 2 or 3 2L multichannel wav files into Dolby Pro Logic II format containing two channels The Dolby Pro Logic II encoded two channel output file is formatted as a wav extensible file with a Dolby metadata chunk Note Two channel source input files processed by this profile pass through that is 8 without Dolby Pro Logic II processing However the output file is formatted as a wav extensible file that includes a Dolby metadata chunk Profile PCM_EC3 1 gt wav PCM to Dolby Digital Plus E AC 3 Encoding WAVE Process gt PCM to Dolby Digital Plus E AC 3 NOTE Multichannel WAVE PCM files are supported PCM Profile PCM_EC3 1 encodes PCM wav files to Dolby Digi
104. value is corrected for all AC 3 programs contained in the Dolby E stream All other metadata is preserved Any Dolby E CRC errors present in the source file are corrected Profile WAV E_WAV E 2 gt Dolby E 337M wav Loudness Correct via Metadata Process gt Dolby E Loudness Correction WAVE w via Metadata dialnorm WAVE w SMPTE 337M Lo gt SMPTE 337M formatted Dolby E Measurement Type gt Speech based formatted Dolby E ITU R BS 1770 Profile WAV E_WAV E 2 performs a Dolby E loudness correction via metadata dialnorm processing on a 20 bit Dolby E file formatted per SMPTE 337M wrapped in a 24 bit wav file The system corrects the dialnorm value for all AC 3 programs contained in the Dolby E stream All other metadata is preserved Dolby DP600 Program Optimizer Manual 79 DP600 Program Optimizer Detailed Profile Descriptions Profile WAV E_AC3 1 gt Dolby E 337M Formatted wav to Dolby Digital AC 3 File ac3 File wl Dolby Digital AC 3 Program 1 WAVE w F SMPTE 337M gt Process gt Dolby E to Dolby Digital AC 3 formatted Dolby E E ac3 File gt Dolby Digital AC 3 Program n Profile WAV E_AC3 1 transcodes a 5 1 or a 5 1 2 Dolby E stream file formatted per SMPTE 337M wrapped in a wav file container to ac3 files Encoded output data rates are automatically provisioned at either 384 kbps for six channel audio or 192 kbp
105. wav to Dolby Digital AC 3 File ac3 File gt Dolby Digital AC 3 Program 1 Process gt Dolby E to Dolby Digital AC 3 WAVE w d SMPTE 337M placa La Ge based ome Bile Dialnorm Metadata Correction only f ac3 File gt Dolby Digital AC 3 Program n Profile WAV E_AC3 3 transcodes a 5 1 or a 5 1 2 Dolby E stream file formatted per SMPTE 337M wrapped in a wav file container to ac3 files Encoded output data rates are automatically provisioned at either 384 kbps for six channel audio or 192 kbps for two channel audio The dialogue normalization value is also automatically provisioned to the correct value for all AC 3 programs contained in the Dolby E stream Any two channel PCM programming not Dolby E data found within the source file is automatically normalized to the same loudness found in the first Dolby E program All remaining AC 3 metadata parameters are provisioned from the AC 3 metadata within each program contained in the Dolby E data file stream Note that only files containing either 5 1 or 5 1 2 Dolby E data are supported Profile WAV E_AC3 4 gt Dolby E 337M wav to Dolby Digital ac3 with adaptive wav PCM Upmix ac3 File gt Dolby Digital AC 3 Program 1 WAVE w SMPTE 337M Process gt Dolby E to Dolby Digital AC 3 formatted Dolby E In OR 2 channel WAVE PCM Upmixed to Or 2 channel 5 1 channel Dolb
106. within the Dolby E tracks is also encoded to a separate set of ac3 files with the appropriate sequence numbering found in the file names and automatically normalized to 27 LKFS All remaining AC 3 metadata parameters are provisioned from the AC 3 metadata within each program contained in the Dolby E data file stream Dolby DP600 Program Optimizer Manual 89 add work order 32 TOMPEerAtUte ode Divine lit 6 applications power supply replacing ccc 51 54 Cable aiii 4 A aa Aa e an Ri 8 described EE 3 4 registerimg ain E E RE ERRE 15 PIV EEN 4 software Satellites aa anios 4 installing sisiane reire oeni a ieia ries 55 terrestrial broadcast ccccccsecesseessceesecesseessecesees 4 UP STAINS nunca iron 55 AUCIO POLE tee 8 SYSLEMUTOSCE eege gedd 6 audio processing System SetuP ai AE A 10 19 With metadata ees SEA 2 work flow integration ociciciononinnonononaneoninnnnaness 3 Without metadata 2 DP600 Client audio transcoding mmcoccconcnnoncncnrncncncinananonrarorononcaracanoso 3 described iii ia 27 audio types Home sereen criando mio tel n 30 ee E DH 4 Gi TN ETA 29 ICAA ia a 4 drive SE Sen dui acid 4 ACA A 6 cable applications onccccconnnnconananonanonanonononcnonanonononononos 4 internal calibrating the touch Screen coconcncnconinnononnrrononroroso 55 LU de 6 43 cancel A a aea aE Eein TIREE 44 System SOtUP cococococoncncncnnnoncncnrncannnncnrnranarannrncnrananos 11 rebuilding EE 49 CD DVD SATIN 0 a at Saved E 5
107. wn in Figure 2 7 A A Y Y cancel Figure 2 7 Set Server Date Time Screen Dolby DP600 Program Optimizer Manual Starting the System for the First Time 10 Press the up and down arrows above and below each field to set the server date and time then press ok 11 Press the Server Time Zone field The Select Region screen appears as shown in Set Time Zone Select Region Atlantic tralia cancel finish Figure 2 8 Select Region Screen 12 Press on your region then press the right arrow The Select City or Zone screen appears for your region as shown in You need to select your closest city to ensure that submitted work orders run at the scheduled time Set Time Zone Select City or Zone cancel finish Figure 2 9 Select City or Zone Screen Dolby DP600 Program Optimizer Manual 13 Using the DP600 13 Press on your closest city then press finish The End User License Agreement screen appears as shown in Figure 2 10 A ATORIES INC DOLBY THE OTHER Y E cancel finish Figure 2 10 License Agreement Screen 14 Read the license agreement and be sure you understand it then press the understand and accept these terms box then press the right arrow The License screen appears This screen displays the unit s Serial Number and user personal identification number PIN Note these two numbers you 1l need them to license your unit for operation You
108. y Digital AC 3 L PCM WAVE ac3 File gt Dolby Digital AC 3 Program n Profile WAV E_AC3 4 transcodes 5 1 or 5 1 2 Dolby E stream files formatted per SMPTE 337M wrapped in a way file container to ac3 files Encoded output data rates are automatically provisioned as six channel and two channel programs at 384 kbps Any two channel PCM programming that is not Dolby E data found within the source file that is the Dolby E 337M wav or two channel PCM wav is automatically upmixed and an independent ac3 file is created for each This includes all two channel PCM wav files processed with this profile and or all two channel PCM audio sequences found within the Dolby E 337M wav data Note This profile supports Dolby E files containing either 5 1 or 5 1 2 Dolby E data and or two channel wav PCM files Dolby DP600 Program Optimizer Manual a DP600 Program Optimizer Detailed Profile Descriptions Profile WAV E_EC3 1 gt Dolby E 337M Formatted wav to Dolby Digital Plus E AC 3 File ec3 File gt Dolby Digital Plus E AC 3 Program 1 EH Process gt Dolby E to Dolby Digital Plus 5 formatted Dolby E E AGS ec3 File i gt Dolby Digital Plus E AC 3 Program n Profile WAV E_EC3 1 transcodes a Dolby E stream file formatted per SMPTE 337M wrapped in a wav file container to ec3 files Encoded output data rates are automatically provisioned at
109. ystems MediaStream system Profile PS_PS 1 gt MPEG 2 Program Stream with Dolby Digital AC 3 dialnorm Correction Process gt Speech based Loudness MPEG 2 Program Stream Estimation and dialnorm correction MPEG 2 Program Stream A ae gt with Dolby Digital AC 3 with Dolby Digital AC 3 Measurement Type gt Speech based dialnorm correct ITU R BS 1770 Profile PS_PS 1 corrects the metadata values dialnorm dynrng and compr within all Dolby Digital AC 3 elementary streams if the measured dialogue loudness is greater than the original dialogue normalization value by 1 dB 84 Dolby DP600 Program Optimizer Manual Profile Descriptions Profile PS_PS 2 gt MPEG 2 Program Stream with Dolby E dialnorm Correction Process gt Speech based Loudness MPEG 2 Program Estimation and dialnorm correction MPEG 2 Program Stream with Dolby E Stream with Dolby E gp S Measurement Type gt Speech based dialnorm correct ITU R BS 1770 Profile PS_PS 2 corrects the dialogue normalization value within all Dolby E elementary streams if the measured dialogue loudness is greater than the original dialogue normalization value by 1 dB Note that this profile assumes the MPEG 2 program stream file was generated by an Avid Pinnacle Systems MediaStream system Profile PS_PS 3 gt MPEG 2 Program Stream with Dolby E dialnorm Correction and MPEG 1 LII Normalization Process gt Gpeech

Download Pdf Manuals

image

Related Search

Related Contents

TL5 - CEC  Grúa autopropulsada o autotransportada  Thermador 200 User's Manual  Problems & Troubleshooting: Specifications: SOLAR POWER  año de los derechos de las personas con discapacidad y  NI 17xx Smart Camera User Manual  BA-305/308/320/330X  Laura Ashley WBLS0133 Installation Guide  MI13 User Manual    

Copyright © All rights reserved.
Failed to retrieve file