Home
Dimplex DF1135M User's Manual
Contents
1. 15 Hang the frame assembly on the mounting hardware of the firebox and secure by follow ing the instructions included with frame 16 Excess electrical cord can be inserted back into the bottom of the unit into the cord storage area Figure 6 Media Tray www dimplex com Fireplace Installation Pedestal Installation Instructions WARNING Failure to install the fireplace as instructed below may result in damage to the equipment and or may expose the user to the risk of fire serious injury illness or death amp CAUTION High temperature keep electrical cords drapery and other furnishings at least 3 ft 0 9m from the front of the heater and away from the side and rear Tools Required 2 Phillips screwdriver 1 Carefully lay the fireplace down on its front NOTE If necessary lay a protective barrier between the front glass and your work surface i e cloth cardboard thick plastic to avoid scratching the glass or your work surface 2 Assemble the pedestal by attaching the vertical supports to the base Figure 7 3 Position the pedestal on the back of the firebox so that it lines up with the provided mounting holes Figure 7 m Verticle Supports Base Pedestal 4 Secure the pedestal to the firebox with the provided screws Figure 8 5 Orient the firebox so that it is standing upright 6 Mount hardw
2. Place the bubble level onto the top of the wall mounting bracket 5 Adjust the wall mounting bracket so the bubble on the level is centered between the two black lines 6 Mark three 3 other mounting screw locations on the wall ensuring that the wall bracket stays level 7 Install the supplied wall anchors on the drywall marked locations by placing a 2 Phillips screwdriver into the recess of the anchor 8 Press the anchor into the wall in the desired marked position while turning the anchor clockwise until it is flush with the wall Fireplace Installation Figure 4 Cover Plates 9 Insert the wall anchor screws through the wall bracket and thread into the wall anchors Tighten the screw Figure 3 10 Install the remaining screws through the bracket and into the wall studs as required NOTE At least two of the mounting screws must be installed into a wall stud 11 Remove the two 2 cover plates from the wall mounting slots in the back of the firebox Figure 4 12 Mount the unit on the wall so that the tabs on the wall bracket have been inserted into the slots on the back of the firebox Figure 5 13 Mount hardware for frame in stallation to unit as described in installation guide provided with frame 14 Carefully pour and evenly dis tribute the supplied media in the Media tray of the firebox Figure 6
3. been repaired except by Dimplex or its authorized service representatives or otherwise altered This limited warranty does further not apply to defects resulting from misuse abuse accident neglect incorrect installation improper maintenance or handling or operation with an incorrect power source What you must do to get service under this limited warranty Defects must be brought to the attention of Dimplex Technical Service by contacting Dimplex at 1 888 DIMPLEX 1 888 346 7539 or 1367 Industrial Road Cambridge Ontario Canada N1R 7G8 Please have proof of purchase catalogue model and serial numbers available when calling Limited warranty service requires a proof of purchase of the product What Dimplex will do in the event of a defect In the event a product or part covered by this limited warranty is proven to be defective in material or workmanship during the 1 year limited warranty period you have the following rights Dimplex will in its sole discretion either repair or replace such defective product or part without charge If 16 www dimplex com A Warranty Dimplex is unable to repair or replace such product or part or if repair or replacement is not commercially practicable or cannot be timely made Dimplex may in lieu of repair or replacement choose to refund the purchase price for such product or part Limited warranty service will be performed solely by dealers or service agents
4. TE Before attempting any operation with the remote pull the plastic insulator strip out from between the remote casing and 13 Operation battery cover Figure 10 Remote Control Initialization Reprogramming If the remote control or remote control receiver has been replaced follow these steps to initialize the remote control and receiver 1 Ensure that power is supplied through the main service panel 2 Turn On Off Switch to 1 Figure 9A 3 Move the 3 Position Switch to the REMOTE position Figure 9B 4 Press and hold the Manual Control Button marked for five 5 seconds Figure 9C After five 5 seconds there is a 10 second window to press any button on the remote control 5 Press any button on the remote control within that 10 seconds This will synchronize the remote control and receiver NOTE You will have only 10 seconds to perform this last step Failure to do so will result in these steps needing to be followed again Battery Replacement To replace the battery 1 Slide battery cover open on the remote control Figure 10 2 Install one 1 12 Volt A23 battery in the battery holder 3 Close the battery cover Oy Battery must be recycled e or disposed of properly Check with your Local Authority or Retailer for recycling advice in your area 14 www dimplex com I Maintenance WARNING Disconnect power before attempting any mainte
5. above an electrical outlet Access to the electrical outlet must be maintained Ensure the installation meets the national and state provincial electrical codes NOTE It is recommended that the bottom of the unit not be mounted higher than 1020mm 40 from the Fireplace Installation ground to maintain an optimized viewing angle of the flame www dimplex com Fireplace Installation amp CAUTION Ensure that the top of the unit is at least 610mm 24 from the ceiling or any object i e Electrical receptacles that may obstruct or be susceptible the flow or temperature of air out of the unit amp CAUTION High temperature keep electrical cords drapery and other furnishings at least 3 ft 0 9m from the front of the heater and away from the side and rear 2 The wall mounting bracket must be mounted to at least two 2 wall studs Studs should be accessed through two 2 wall bracket holes in one of the following combinations A amp F B amp D or C amp E Figure 1 NOTE Wall anchors must Figure 3 Wall anchor Screw S Wall bracket be installed in the appropriate wall locations to fasten the wall bracket through the remaining holes Figure 2 For example if you plan to secure the bracket to studs through holes A amp D install anchors centered on holes B and C 3 Hold the wall mounting bracket on the wall and mark the location of ONE 1 of the mounting holes 4
6. are for trim in stallation to unit as described in installation guide provided with trim 7 Carefully pour and evenly dis tribute the supplied media in 11 Fireplace Installation the Media tray of the firebox Figure 6 8 Hang the frame assembly on the mounting hardware of the firebox and secure by follow ing the instructions included with frame 9 Excess electrical cord can be inserted back into the bottom of the unit into the cord storage area Operation Figure 9 The manual controls for the electric fireplace are located on the right end of the unit Figure 9 A On Off Switch The On Off Switch supplies power to all fireplace functions When the switch is in the I position the unit is on When in the O position the fireplace is off B 3 Position Switch The 3 Position Switch changes the mode the fireplace operates in and has three 3 positions MANUAL OFF and REMOTE When in REMOTE mode the fireplace s three levels of operation are controlled by the ON and OFF buttons of the remote control In OFF mode power to all functions is cut off In MANUAL mode the fireplace s three levels of operation are controlled by the Manual Control Buttons 12 www dimplex com Operation C Manual Control Buttons The Manual Control Buttons operate the fireplace levels sequentially from off f
7. c fireplaces Please carefully read and save these instructions amp CAUTION Read all instructions and warnings carefully before starting installation Failure to follow these instructions may result in a possible electric shock fire hazard and will void the warranty Please record your model and serial numbers below for future reference model and serial numbers can be found on the Model and Serial Number Label of your fireplace A a gt Model Number UDEL CAT No MOD SERIAL No po Serial Number Label STOP NO NEED TO RETURN TO THE STORE Questions with operation or assembly Require Parts Information Product Under Manufacturer s Warranty Contact us at www dimplex com customer support For Troubleshooting and Technical Support Lam OR Toll Free 1 888 DIMPLEX 1 888 346 7539 Monday to Friday 8 00 a m to 4 30 p m EST Please have your model number and product serial number ready See above amp IMPORTANT INSTRUCTIONS When using electrical appliances basic precautions should always be followed to reduce the risk of fire electric shock and injury to persons including the following Read all instructions before using the electric fireplace 2 This fireplace is hot when in use To avoid burns do not let bare skin touch hot surfaces The trim around the heater outlet becomes hot during heat
8. d is stored or secured to avoid tripping or snagging to reduce the risk of fire electric shock or injury to persons Construction and electrical outlet wiring must comply with local building codes and other applicable regulations to reduce the risk of fire electric shock and injury to persons Do not attempt to wire your own new outlets or circuits To reduce the risk of fire electric 7 Fireplace Installation shock or injury to persons always use a licensed electrician WARNING The supplied mounting components are designed for use with Dimplex fireplaces only Improper use or use for purposes other than intended may cause damage or injury Wall Mounting Instructions WARNING Failure to install the fireplace as instructed below may result in damage to the equipment and or may expose the user to the risk of fire serious injury illness or death WARNING The fireplace requires the wall mounting bracket screws to be installed into a minimum of two wall studs Figure 1 Tools Required 2 Phillips screwdriver Pencil Slot screwdriver Bubble level supplied Drill and drill bits as required Approximate time 30 minutes for installation 1 Select an appropriate location to mount the unit on a wall Figure 1 610 mm 24 MINIMUM 1020 mm 40 RECOMMENDED Figure 2 4 of 4 mti gt I mi
9. d store so as to avoid damage CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN NO USER SERVICABLE PARTS INSIDE SAVE THESE INSTRUCTIONS 4 IMPORTANT INSTRUCTIONS WARNING Remote control contains small batteries Keep away from children If swallowed seek medical attention immediately WARNING Do not install battery backwards charge put in fire or mix with used or other battery types may explode or leak causing injury NOTE Changes or modifications not expressly approved by the party responsible for compliance could void user s authority to operate the equipment NOTE This equipment has been tested and found to comply with the limits for Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Increase the separation between the equipment and the receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician f
10. eX Dimplex Better solutions through innovation Owner s Manual ba Model DF1135M DF1136L IMPORTANT SAFETY INFORMATION Always read this manual first before attempting to install or use this fireplace For your safety always comply with all warnings and safety instructions contained in this manual to prevent personal injury or property damage To view the full line of Dimplex products please visit www dimplex com 7212270100R03 Table of Contents Welcome amp Congratulations 3 IMPORTANT INSTRUCTIONS 4 Quick Reference Guide 05 T Fireplace Installation cesse keen mme 7 qr Operation cascada crcakedeavsasveaacs 12 oS Maintenance l i eese 16 WOMAN ean 2 423 por Fd eho do eS dep ace 4 17 oe Replacement Parts 0 19 Always use a qualified technician NOTE Procedures and or service agency to repair techniques that are considered this fireplace important enough to emphasize amp CAUTION Procedures and techniques which if not carefully followed will result in damage to the equipment WARNING Procedures and techniques which if not carefully followed will expose the user to the risk of fire serious injury or death 2 www dimplex com i Welcome amp Congratulations Thank you and congratulations for choosing to purchase an electric fireplace from Dimplex the world leader in electri
11. er operation 3 Extreme caution is necessary when any heater is used by or near children or invalids and whenever the unit is left operating and unattended 4 Always unplug the fireplace when not in use 8 Young children should be supervised to ensure that they do not play with the appliance The appliance is not intended for use by young children or infirmed persons without supervision If the supply cord is damaged it must be replaced by the manufacturer or its service agent or a qualified person in order to avoid a hazard Do not operate any unit with a damaged cord or plug or if the heater has malfunctioned or if the electric fireplace has been dropped or damaged in any manner contact Dimplex Technical Service at 1 888 346 7539 9 Do not use outdoors This fireplace is not intended for use in bathrooms laundry areas and similar indoor locations Never locate heater where it may fall into a bathtub or other water container High temperature keep electrical cords drapery and other furnishings at least 3 ft 0 9m from the front of the heater and away from the side and rear 2 Do not run the cord under carpeting Do not cover cord with throw rugs runners or the like Arrange cord away from traffic area and where it will not be tripped over 3 Do not locate the unit directly below a fixed electrical convenience outlet To disconnect the fireplace turn the controls off t
12. ese seed RU edie db Shae de amba des 5902430200RP X Dimplex c ULJus Dimplex North America Limited 1367 Industrial Road Cambridge ON Canada N1R 7G8 2012 Dimplex North America Limited 18 www dimplex com
13. hen remove the plug from the outlet www dimplex com 4 IMPORTANT INSTRUCTIONS 5 Do not insert or allow foreign objects to enter any ventilation or exhaust opening as this may cause an electric shock or fire or damage to the heater Do not block air intake or exhaust in any manner Do not use on soft surfaces like a bed where openings may become blocked All electrical heaters have hot and arcing or sparking parts inside Do not use in areas where gasoline paint or flammable liquids are used or stored or where the unit will be exposed to flammable vapors Do not modify the electric fireplace Use it only as described in this manual Any other use not recommended by the manufacturer may cause fire electric shock or injury to persons Avoid the use of an extension cord Extension cords may overheat and cause a risk of fire This heater is not intended for use with an extension cord Plug the cord directly into an appropriate wall receptacle Do not burn wood or other materials in the electric fireplace Do not strike the fireplace glass Always use a certified electrician should new circuits or outlets be required 3 Always use properly grounded fused and polarized outlets Disconnect all power supply before performing any cleaning maintenance or relocation of the unit 65 When transporting or storing the unit and cord keep in a dry place free from excessive vibration an
14. lames only to flames and low heat to flames and high heat The level is increased every time the I button is pressed and the fireplace can be turned off at any point by pressing the O button Resetting The Temperature Cutoff Switch Should the heater overheat an automatic switch will turn the heater off and it will not come back on without being reset The temperature cutoff switch can be reset by unplugging the unit waiting five 5 minutes and plugging the unit back in amp CAUTION If you need to continuously reset the heater unplug the unit and call Dimplex customer service at 1 888 DIMPLEX 1 888 346 7539 Remote Control The fireplace is supplied with a radio frequency remote control This remote control has a range of approximately 50 feet 15 25 Figure 10 On Button Off Button Plastic Strip Battery Cover m it does not have to be pointed at the fireplace and can pass through most obstacles including walls It is supplied with one of hundreds of independent frequencies to prevent interference with other units Remote Control Usage The remote control operates the fireplace levels sequentially from off flames only to flames and low heat to flames and high heat The level is increased every time the ON button is pressed on the remote control and the fireplace can be turned off at any point by pressing the OFF button NO
15. nance or cleaning to reduce the risk of fire electric shock or damage to persons Partially Reflective Glass Cleaning The Partially Reflective Glass is cleaned in the factory during the assembly operation During shipment installation handling etc the Partially Reflective Glass may collect dust particles these can be removed by dusting lightly with a clean dry cloth To remove fingerprints or other marks the Partially Reflective Glass can be cleaned with a damp cloth The Partially Reflective Glass should be completely dried with a lint free cloth to prevent water spots To prevent scratching do not use abrasive cleaners Fireplace Surface Cleaning Use only a damp cloth to clean painted surfaces of the fireplace Do not use abrasive cleaners Servicing Except for installation and cleaning described in this manual an authorized service representative should perform any other servicing 15 Z Warranty Products to which this limited warranty applies This limited warranty applies to the following models of your newly purchased Dimplex electric fireplace DF1135M or DF1136L This limited warranty applies only to purchases made in any province of Canada except for Yukon Territory Nunavut or Northwest Territories or in any of the 50 States of the USA and the District of Columbia except for Hawaii and Alaska This limited warranty applies to the original purchaser of the product only and is not
16. of Dimplex authorized to provide limited warranty services Dimplex will not be responsible for and the limited warranty services shall not include any expense incurred for installation or removal of the product or part or any replacement product or part or any labour or transportation costs Such costs shall be the purchaser s responsibility What Dimplex and its dealers and service agents are also not responsible for IN NO EVENT WILL DIMPLEX OR ITS DIRECTORS OFFICERS OR AGENTS BE LIABLE TO the PURCHASER OR ANY THIRD PARTY WHETHER IN CONTRACT IN TORT OR ON ANY OTHER BASIS FOR ANY INDIRECT SPECIAL PUNITIVE EXEMPLARY CONSEQUENTIAL OR INCIDENTAL LOSS COST OR DAMAGE ARISING OUT OF OR IN CONNECTION WITH THE SALE MAINTENANCE USE OR INABILITY TO USE THE PRODUCT EVEN IF DIMPLEX OR ITS DIRECTORS OFFICERS OR AGENTS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH LOSSES COSTS OR DAMAGES OR IF SUCH LOSSES COSTS OR DAMAGES ARE FORESEEABLE IN NO EVENT WILL DIMPLEX OR ITS OFFICERS DIRECTORS OR AGENTS BE LIABLE FOR ANY DIRECT LOSSES COSTS OR DAMAGES THAT EXCEED THE PURCHASE PRICE OF THE PRODUCT SOME JURISDICTIONS DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT APPLY TO THE PURCHASER How State and Provincial law apply This limited warranty gives you specific legal rights and you may also have other rights which vary fr
17. om jurisdiction to jurisdiction The provisions of the United Nations Convention on Contracts for the Sale of Goods shall not apply to this limited warranty or the sale of products covered by this limited warranty 17 oS Replacement Parts Heater Assembly with Cutout 0 0 0 00000 9600560100RP POWEr COM pP TTE 4100010800RP Flicker MOIO utro ice tiie deity eee vod eh ee 2000210500RP Flicker ROQ pe 5901070200RP ONOM SWIECh i4 trees eter A dba ae us 2800070700RP Remote Switchboard llle 3000820300RP Remote Control Receiver 2 00 00 cece eee eee 3000820100RP Remote Control 2 nius ae eee eee Raw ect ae wee ha e 3000370900RP Mounting Hardware Kit llle 9600350100RP Mounting Bracket sees e ee pes Ree ee 1017130259RP Pedestal Bases cei ieee bee Ree oon RE RUE 112440010FRP Pedestal Vertical Supports 0 00000 e eee 1025260159RP DF1135 Partially Reflective Glass 0 00 00 e eee 5902420100RP Flame Panel e px ead C bara eee eee eee ee dns 5902400100RP LED Light Asseribly 22 1 des oe Dr Meee 3000830100RP LED Driver BOSE 22 eR pex yeep tAn Pura 3000810200RP Miste r WIL SET 5902430100RP DF1136 Partially Reflective Glass 00 00 0004 e eu 5902420200RP Flame Panel 4 2 x abe Shek dd obe Gators ROCA aes 5902460100RP LED Light Assembly eese esee esee 3000830102RP LED Driver BOaEd cese neds me ean eae Ree ERE eRe 3000810100RP Media Tray i n
18. or help Operation is subject to the following two conditions 1 this device may not cause interference and 2 this device must accept any interference including interference that may cause undesired operation of the device www dimplex com Quick Reference Guide 1 Before using the fireplace verify Are the circuit breakers for the unit on Are the light bulbs loose To check follow the instructions for replacing the light bulbs under the maintenance section of this manual Fireplace Installation Site Selection The unit is packaged with two types of mounting options e Wall mounting Surface Pedestal NOTE A 15 Amp 120 Volt circuit is required A dedicated circuit is preferred but not essential in all cases A dedicated circuit will be required if after installation the circuit breaker trips or the fuse blows on a regular basis when the heater is operating Additional appliances on the same circuit may exceed the current rating of the circuit breaker 2 If you have any technical questions or concerns regarding the operation of your electric fireplace or require service contact customer service The heater may emit a slight harmless odor when first used This odor is a normal condition caused by the initial heating of internal heater parts WARNING Ensure the power cord is not installed so that it is pinched or against a sharp edge and ensure that the power cor
19. transferable Products excluded from this limited warranty Light bulbs are not covered by this limited warranty and are the sole responsibility of the owner purchaser Products purchased in Yukon Territory Nunavut Northwest Territories Hawaii or Alaska are not covered by this limited warranty Products purchased in these States provinces or territories are sold AS IS without warranty or condition of any kind including without limitation any implied warranties or conditions of merchantability or fitness for a particular purpose and the entire risk of as to the quality and performance of the products is with the purchaser and in the event of a defect the purchaser assumes the entire cost of all necessary servicing or repair What this limited warranty covers and for how long Products covered by this limited warranty have been tested and inspected prior to shipment and subject to the provisions of this warranty Dimplex warrants such products to be free from defects in material and workmanship for a period of 1 year from the date of the first purchase of such products The limited 1 year warranty period also applies to any implied warranties that may exist under applicable law Some jurisdictions do not allow limitations on how long an implied warranty lasts so the above limitation may not apply to the purchaser What this limited warranty does not cover This limited warranty does not apply to products that have
Download Pdf Manuals
Related Search
Related Contents
Sony Confidential VPCEH Series SERVICE MANUAL C10 User Maual Linksys EF24G2 Switch User Manual Understanding the Interrupt Control Unit of the 80C186EC Liberty H0104AC-W-O3 Installation Guide QTLMap 0.8 User's guide System and method for pushing information from a host system to a Transcend Transcend DDR3 RAM Unità di comando e controllo REOVIB MTS 440/ 442 Trak Pak II Operating and Service Manual Copyright © All rights reserved.
Failed to retrieve file