Home
Digi MIL-S3160 User's Manual
Contents
1. Never push objects of any kind into this product grounding type power outlet This is a safety feature through cabinet slots as they may touch dangerous If you are unable to insert the plug into the outlet voltage points or short out parts that could result in a contact your electrician to replace your obsolete risk of fire or electric shock Never spill liquid of outlet Do not defeat the purpose of the grounding any kind on the product type plug 6 Do not attempt to service this product yourself as 3 Do not allow anything to rest on the power cord Do opening or removing covers may expose you to not locate this product where persons will walk on dangerous voltage points or other risks Refer all the cord servicing to servicing to service personnel s TECHNICAL INFORMATION Standards Compatibility ISO IEC 802 2 3 IEEE 802 3 IEEE 802 3U IEEE 802 3X Interfaces RJ 45 fully shielded connectors for 10Base T and 100Base TX Fast Ethernet Physical Length 330mm 13 in Height 43mm 1 69 in Depth 230mm 9 06 in Weight 2 6Kg 5 691b Five Year Limited Warranty Digi International warrants to the original consumer or purchaser that each of its products and all components thereof will be free from defects in material and or workmanship for a period of five years from the original factory shipment date Any warranty hereunder is extended to the original consumer or purchaser and is not assignable Digi makes no express or im
2. panel The speed and full or half duplex modes of the ports are automatically determined when users connect the switch to 10Base T and 100Base TX devices The 16 or 24 RJ 45 auto negotiation ports simplify migration of 10 Mbps Ethernet to 100 Mbps Fast Ethernet Normal Uplink Push Button One normal uplink push button on the front panel allows users to select the 16 or 24 port to connect to a PC ora hub or switch With this normal uplink push button feature users can connect with network devices A link LED is lit when there is a successful connection The default setting is in the normal MDI X position 1 e the long button position The port is configured to connect with a PC using a straight through twisted pair cable When the push button is pressed MDT i e the short button position connection is made with a hub or a switch using a straight through twisted pair cable Push button in the short position MDI 16 port 10 100 Dual Speed Switch SY Push button in the long position MDI X Connecting to a Desktop The switch is connected to the desktop to form a small network You can build the network as shown in the figure To improve the network efficiency it is better to have 200 Mbps full duplex operation between the server and switch if the LAN adapter on the server can operate in full duplex mode Connecting to a Switch or a Hub Swit
3. InstallationGuide MIL S3160 16 port 10 100 Dual Speed Switch MIL S3170 24 port 10 100 Dual Speed Switch INTRODUCTION Thanks for purchasing one of the MIL S3100 family of dual speed switches They provide dedicated bandwidths of 10 100 Mbps throughput per port to the desktop With features such as auto negotiation and half full duplex these switches offer smooth network migrations and easy upgrades to network capacity IEEE802 3X flow control in full duplex operation One uplink push button is provided for cascading Auto negotiation supported for each port Visual diagnostic LED s supported 13 inch rack mount width Standard IU chassis height Internal switching power supply The MIL S3100 family of 16 or 24 port 10 100 dual speed switches has the following features Complies with IEEE802 3 IEEE802 3U and IEEE802 3X standards x 16 or 24 10 100 Mbps auto negotiation switch ports Back pressure collision based flow control in half duplex operation MS61624V01ADS PACKAGE CONTENTS Before you begin verify that your package contains the following items 16 or 24 port 10 100 dual speed switch Self adhesive rubber pads for desktop installation AC Power cord Rack Mounting kit for rack installation Installation guide 24 Port 10 100 Dual Speed Switch gt Inner Be sl Installation Guide How TO USE THE 16 O
4. R 24 PORT 10 100 DUAL SPEED SWITCH LED Display 16 Port 10 100 Dual Speed Switch i ee Hd Ei Digi eeee Fill Collision Link Activity 10Mbps Green 100MI low eco e Full Collision Link Activity MIL S3160 Power gt ee 9 10 11 12 13 14 15 16 Uplink push button LIIIIIII is Wh Normal Uplink MIL S3170 Power ee oe oo eee 13 14 15 16 17 18 19 20 21 22 23 24 CH SL 100 240VAC LED s The LED s on the front panel provide visual presentation to show the following status Status of the switch s power supply Connection speed of 10 Mbps or 100 Mbps Data activity on the segment Full or half duplex operation mode Power Green The power is on Off Power is off Full Col Off There is no link or half duplex operation mode established and no collision occurs Yellow Operation mode is full duplex Flashing Yellow The port is in half duplex mode and collisions occur Link Activity Off A link is not established on the port Green A 10 Mbps link is successfully established on the port Flashing Green A 10 Mbps link is established and data transmission or receive activity occurs on the port A 100 Mbps link is established on the port Flashing Yellow A 100 Mbps link is established and data is transmitted or received Yellow 16 or 24 RJ 45 10 100 Dual Speed Switching Ports There are 16 or 24 RJ 45 ports on the front
5. ch to switch or switch to hub connections are made by connecting the 16 or 24 port to a port or to the other hub or switch with the normal uplink push button pressed in With 100Base TX the maximum network length is approximately 205 meters with UTP cable The maximum length between hubs or switch to hub is 100 meters loa J 100Mbps MOUNTING KIT INSTRUCTION The 16 or 24 port 10 100 Dual Speed Switch is supplied Rack mounting in a rack with two mounting brackets six screws and four rubber Locate the mounting bracket over the mounting feet for mounting the rack or putting it on a flat surface holes Insert the screw through the bracket and into the On a flat surface bracket mounting holes in the switch Apply four rubber pads to the bottom of the unit Insert the unit into the 19 inch rack n Put the switch on the flat surface FCC COMPLIANCE STATEMENT This equipment generates and uses radio frequency energy and if not installed and used properly that is in strict accordance with the instructions provided with the equipment may cause interference to radio and TV reception The equipment has been tested and found to comply with the limits for a Class A computing device in accordance with the specifications in Subpart B of Part 15 of FCC rules which are designed to provide reasonable protection against such interference in a residential i
6. nstallation However there is no guarantee that interference will not occur in a particular installation If you suspect this equipment is causing interference turn your switch on and off while your radio or TV is showing interference If the interference disappears when you turn the switch off and reappears when you turn the switch on something in the switch is causing interference You can try to correct the interference by one or more of the following measures Plug the computer which has the equipment installed into a different power outlet so that the equipment and the receiver are on different branch circuits Reorient the receiving radio or TV antenna where this may be done safely If necessary you should consult the place of purchase or an experienced radio television technician for additional suggestions SAFETY INSTRUTIONS 1 This product should be operated from the type of 4 If an extension cord is used with this product make power source indicated on the marking label If you sure that the total ampere ratings on the products are not sure of the type of power available consult plugged into the extension cord do not exceed the your dealer or local power company extension cord ampere rating Also make sure that 2 This product is equipped with a three wire the total of all products plugged into the wall outlet grounding type plug a plug having a third does not exceed 15 amperes grounding pin This plug will only fit into a 5
7. plied warranties including but not limited to any implied warranty of merchantability or fitness for a particular purpose except as expressly set forth in this warranty In no event shall Digi be liable for incidental or consequential damages costs or expenses arising out of or in connection with the performance of the product delivered hereunder Digi will in no case cover damages arising out of the product being used in a negligent fashion or manner b 16 port 10 100 Dual Speed Switch Input Ratings 100 to 240 VAC 50 to 60 Hz Power consumption 23 8 W 24 port 10 100 Dual Speed Switch Input Ratings 100 to 240 VAC 50 to 60 Hz Power consumption 33 3 W Environmental Specifications Operating temperature 0 to 40 C Storage temperature 20 to 70 C Operating Humidity 10 to 90 RH Storage Humidity 10 to 95 RH Electromagnetic Emission FCC Class A CE Class A VCCI Class A Safety Approval UL CUL TUV Trademarks Digi International and the Digi Logo are trademarks of Digi International All other products and brands are trademarks of their respective holders All rights reserved To Contact Digi For prompt response when calling for service information have the following information ready e Product serial number and rev e Date of purchase e Vendor or place of purchase You can reach Digi LAN technical support at 408 744 2751 Or E mail at sun tech digi com Address 1299 Orleans Drive Sunny
8. vale CA 94089 Voice 408 744 2775 Fax 408 744 2793 E mail info digi com Copyright 1999 Digi International P N 90000139 Rev A
Download Pdf Manuals
Related Search
Related Contents
User Manual Manual de instalación y funcionamiento WWK 300 M&L La photo numérique pour les filles Catálogo / Ficha técnica - Productos multimedia para coches ELECTRONIC MDD BABY SCALE MODEL 630 Un éclairage sur le modèle de l`économie collaborative COLA PVC GEL Add-On Computer Peripherals (ACP) XFP10GLR-192SR-L-AO network transceiver module Copyright © All rights reserved.