Home

Dialogic IPT10000C User's Manual

image

Contents

1. Main Board Power LED Green LED Link Established indicator for 100BASE TX port Green LED Link Established indicator for 1O00BASE T port Out of Service LED Indicates board is out of service or in reset from the host Board Extractor with red locking tab J1 Connector to Compact PCI backplane J2 Connector to Compact PCI backplane J3 Connector to Compact PCI backplane 9 J4 Connector to Compact PCI backplane 10 J5 Connector to Compact PCI backplane 11 Baseboard retaining screw 12 Yellow LED Activity indicator for 100BASE TX port 2 Remove the cover plate or open front chassis door 3 Select an empty peripheral expansion bus slot 4 Use the slot s board guides as you insert the board into the chassis slot Make sure that the tabs on the board extractors engage the guide holes in the chassis card cage then lock down the board extractors until the red locking tabs snap shut Rear I O Module Yellow LED Link Not Established indicator for 1000BASE T port 100BT 0 Port O connector to 100BASE TX Ethernet Network 15 100BT 1 Port 1 connector to 1O0OBASE TX Ethernet Network 1000BT 0 Port 0 connector to 1000BASE T Ethernet Network 1000BT 1 Port 1 connector to 1000BASE T Ethernet Network J5 Rear I O module connector to Compact PCI backplane J3 Rear I O module connector to Compact PCI backplane Rear I O module retaining screw CAUTION cPCI backplane pins are bent easily
2. Make sure that the board is seated with hand pressure before fully seating board If the board extractors are used to seat the board make sure to seat evenly Note f the power to the chassis is on power is automatically applied to the board the Out of Service LED lights briefly and then goes out and the Power LED goes on 5 Tighten the retaining screws to secure the board firmly in the chassis slot 6 Connect the Rear I O module to the rear of the slot selected in Step 3 CAUTION Damage to the board will result if an incorrect rear I O module is used Use a Rear I O module only and be careful to install the module in the correct slot Use the slot s board guides as you insert the board into the chassis slot Make sure that the tabs on the board extractors engage the guide holes in the chassis card cage then lock down the board extractors until the red locking tabs snap shut CAUTION cPCI backplane pins are bent easily Make sure that the board is seated with hand pressure before fully seating board If the board extractors are used to seat the board make sure to seat evenly 7 Tighten the retaining screws to secure the board firmly in the chassis slot 8 Select a new slot and repeat steps 4 7 for each board you are installing 9 If the power to the chassis was turned OFF in step 1 turn the power to the chassis ON Connecting External Cables Connect either the 100BASE TX or 1000BASE T Ethernet cabl
3. that may be contained in this document INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH DIALOGIC PRODUCTS NO LICENSE EXPRESS OR IMPLIED BY ESTOPPEL OR OTHERWISE TO ANY INTELLECTUAL PROPERTY RIGHTS IS GRANTED BY THIS DOCUMENT EXCEPT AS PROVIDED IN A SIGNED AGREEMENT BETWEEN YOU AND DIALOGIC DIALOGIC ASSUMES NO LIABILITY WHATSOEVER AND DIALOGIC DISCLAIMS ANY EXPRESS OR IMPLIED WARRANTY RELATING TO SALE AND OR USE OF DIALOGIC PRODUCTS INCLUDING LIABILITY OR WARRANTIES RELATING TO FITNESS FOR A PARTICULAR PURPOSE MERCHANTABILITY OR INFRINGEMENT OF ANY INTELLECTUAL PROPERTY RIGHT OF A THIRD PARTY Dialogic products are not intended for use in medical life saving life sustaining critical control or safety systems or in nuclear facility applications It is possible that the use or implementation of any one of the concepts applications or ideas described in this document in marketing collateral produced by or on web pages maintained by Dialogic may infringe one or more patents or other intellectual property rights owned by third parties Dialogic does not provide any intellectual property licenses with the sale of Dialogic products other than a license to use such product in accordance with intellectual property owned or validly licensed by Dialogic and no such licenses are provided except pursuant to a signed agreement with Dialogic More detailed information about such intellectual property is available from Dialogic s legal de
4. Dialogic IPT10000C IP Board Quick Install Card Part Number 64 0082 02 Copyright 2004 2007 D1 a fg C Dialogic Corporation All Rights Reserved Before You Begin Protecting the Board from Damage CAUTION All computer boards are sensitive to electrostatic discharge ESD Handle all static sensitive boards and components at a static safe work area and observe anti static precautions at all times If you are not familiar with ESD safety precautions visit http Awww dialogic com support hwinstall to learn more Unpacking the Board Unpack the Dialogic IPT10000C IP Board board according to the following steps 1 Prepare a static safeguarded work area 2 Carefully remove the board from the shipping carton and anti static packaging Handle the board by the edges and avoid touching the board s components 3 Lay the board on the static dissipative work surface Note Place boards in static shielding bags when carrying boards from station to station CAUTION Do not remove the board from the anti static packaging until you are ready to install it Observe proper anti static precautions at all times Installing the Hardware Note The hardware must be installed before the system software 1 Turn the power to the chassis OFF if you do not have a live insertion system If you have live insertion capability the power to the chassis can remain ON Physical Description
5. board extractors are equipped with red locking tabs that lock when the board is correctly positioned in the chassis CAUTION When removing the board if the red locking tabs on the extractors are not pressed while applying pressure to the extractors there is a risk of breaking To remove the board from the chassis simultaneously press down both red locking tabs see the figure below on the extractors before applying pressure away from the center of the board to release the board from the chassis Press and hold down the red locking tabs on both board extractors before applying pressure to the board extractors x a Removing the Rear I O Module In a live insertion powered on system do not remove and replace a Rear I O module while the main front board is in service Remove the front board first then remove and replace the Rear I O module and then reinsert the front board Remove the Rear I O module using the red locking tabs as described above Warranty and Return Information For specific warranty information for this board refer to the Warranty section of the Products page located at this URL http www dialogic com warranties Contacting Technical Support Dialogic provides technical support for its products through a network of value added distributors who are trained to answer technical questions on installing and configuring Dialogic products If you are unsure how to contact your support channel pleas
6. e call Dialogic in the United States at 973 967 6600 9am 5pm EST and we will assist in obtaining the appropriate support channel Outside the United States please refer to http www dialogic com support contact to obtain local contact information Dialogic also provides direct support via Dialogic Pro Services agreements For more details of direct support from Dialogic please refer to http www dialogic com support DialogicPro Returning a Product To return a board for warranty repair or any other returns please refer to the following http Awww dialogic com support hwfaults Sales Assistance If you have a sales question please contact your local Sales Representative or the Regional Sales Office for your area Address telephone and fax numbers are available at the Dialogic website located at http Awww dialogic com contact htm To purchase Dialogic products please refer to the following website to locate the appropriate supplier http Awww dialogic com purchase htm All contents of this document are furnished for informational use only and are subject to change without notice and do not represent a commitment on the part of Dialogic Corporation or its subsidiaries Dialogic Reasonable effort is made to ensure the accuracy of the information contained in the document However Dialogic does not warrant the accuracy of this information and cannot accept responsibility for errors inaccuracies or omissions
7. es to the appropriate Rear I O module connectors When connecting the Ethernet cables install a snap fit ferrite clamp on each cable as close as possible to the connector on the Rear I O module Ferrite Diam ete 5mm approx Ethernet Cable CAUTION A ferrite clamp must be installed on all cables that connect to Ethernet connectors to meet EMC requirements Two ferrite clamps have been provided therefore only two cables can be connected at one time 100BASE TX Ethernet Connector Pinouts Link Established P in Label Indicator _ 1 RD lare En a 2 RD 3 TD L a NG K Ne Activity Ed 6 ToD Indicator T y N C Yellow 8 Nc 100BT 0 1000BASE T Ethernet Connector Pinouts Link Pin 4 Established Pin Label Indicator _ 1 TP 0 Green 2 TP 0 3 TP t4 4 TP a Link Not 5 TP 2 Established 6 DE Te Indicator r TP 3 Yellow 8 TP 3 After Installing Hardware After installing the hardware run the Dialogic Configuration Manager DCM as described in the installation instructions included with the Dialogic System Software to configure your system For technical specifications and product information go to http Awww dialogic com products htm Uninstalling the Hardware Removing the Main Board Exercise caution when removing the board from a cPCl chassis The
8. partment at 9800 Cavendish Blvd 5 Floor Montreal Quebec Canada H4M 2V9 Dialogic encourages all users of its products to procure all necessary intellectual property licenses required to implement any concepts or applications and does not condone or encourage any intellectual property infringement and disclaims any responsibility related thereto These intellectual property licenses may differ from country to country and it is the responsibility of those who develop the concepts or applications to be aware of and comply with different national license requirements Dialogic Diva Eicon Eicon Networks Eiconcard and SIPcontrol among others are either registered trademarks or trademarks of Dialogic Dialogic s trademarks may be used publicly only with permission from Dialogic Such permission may only be granted by Dialogic s legal department at 9800 Cavendish Blvd 5th Floor Montreal Quebec Canada H4M 2V9 Any authorized use of Di trademarks will be subject to full respect of the trademark guidelines published by Dialogic from time to time and any use of Dialogic s trademarks requires proper acknowledgement The names of actual companies and products mentioned herein are the trademarks of their respective owners