1. Motion Sensor Light Control Model SH 5710 Features e Turns on lighting when motion is detected e Automatically turns lighting off e Photocell keeps the lighting off during daylight hours LED indicates motion was sensed day or night Additional energy savings with compact fluorescent bulbs This package includes Q Rubber Plug Lamp Holders O Cover Plate Light Control 2 Wire Connectors Mounting Strap Mounting Bolt il lt 2 Compact Fluorescent Bulbs Gasket 6 Screws 3 sizes included Requirements The Light Control requires 120 volts AC If you want to use Manual Mode the control must be wired through a switch Some codes require qualified electrician This product is intended for use with the enclosed gasket and with a junction box marked for use in wet locations Note This productis not recommended for use where the outside temperature is below 10 F installation by a 2004 DESA Specialty Products OPERATION Hate e Manual UntiDawn OX resets to Auto Mode at dawn Note When first turned on wait about 1 2 minutes for the circuitry to calibrate TEST Put the ON TIME switch on the bottom ON TIME of the sensor in the TEST position 10 5 1 TEST AUTO Put the ON TIME switch in the 1 5 or 10 minute position Note Although the 1 minute mode can be used the 5 or 10 minute mod
2. detector No deje que las lamparas bloqueen la placa translucida M Placa transl cida Para evitar da o causado por el agua y riesgo de electrocuci n mantenga los portal mparas a 30 debajo de la l nea horizontal O Ajustelos portal mparas aflojando las contratuercas pero no los gire m s de 180 de la calibraci n hecha en f brica Cuando atornille las bombillas no las ajuste demasiado O Instale las tapas de las l mparas Alinee las aletas de las tapas de la l mpara con los agujeros de los portal mparas Presione con suavidad las tapas de las l mparas hasta que las aletas se asienten en los agujeros sobre los portal mparas 598 1163 01 PRUEBA Y AJUSTE O Prenda el cortacircuitos y el interruptor de luz NOTA El detector tiene un per odo de cerca de 1 2 minutos de calentamiento antes de detectar movimiento Cuando lo prenda por primera vez espere 1 2 minutos O Gire el control RANGE a la posici n media y el control ON TIME a la posici n TEST ON TIME NY RANGE SS a 1051 TEST a Oo Parte de abajo del detector Evite apuntar el control hacia e Objetos que cambien r pidamente de temperatura tales como ductos de calefacci n y acondicionadores de aire Estas fuentes de calor pueden causar falsas alarmas e Areas donde animales dom sticos o el tr fico puedan activar el control e Los objetos grandes cercanos y de colores resplandecientes que r
3. AS O SOBREENTENDIDAS INCLUYENDO CUALQUIER GARANT A REPRESENTACI N O CONDICI N DE COMERCIABILIDAD O QUE LOS PRODUCTOS SE ADAPTEN PARA CUALQUIER PROP SITO O USO EN PARTICULAR Y ESPECIFICAMENTE EN LUGAR DE TODOS LOS DA OS ESPECIALES INDIRECTOS INCIDENTALES Y CONSECUENTES LA REPARACI N O EL REEMPLAZO DEBER A SER LA NICA SOLUCI N DEL CLIENTE Y NO HABR RESPONSABILIDAD POR PARTE DE DESA SPECIALTY PRODUCTS M POR CUALQUIER DA O ESPECIAL INDIRECTO INCIDENTAL O CONSECUENTE INCLUIDOS PERO NO LIMITADOS A CUALQUIER P RDIDA DE NEGOCIO O GANACIAS SEAN O NO PREVISIBLES Algunos estados o provincias no permiten la exclusi n o limitaci n de da os incidentales o consecuentes de modo que la limitaci n o exclusi n arriba indicada puede que no se aplique a Ud Para reclamos por la garant a se requiere la prueba de compra 8 598 1163 01
4. AUTOMATICO Apague el interruptor por un segundo y vu lvalo a prender para conmutar entre MODO AUTOMATICO y MANUAL 1 segundo APAGADO luego SA prendalo Resumen de las modalidades del interruptor El modo manual funciona solo con el interruptor ON TIME en la posicion 1 50 10 Mueva el interruptor de tiempo ON TIME a 1 5 0 10 minutos Apague el interruptor por un segundo y pr ndalo de nuevo MODO MANUAL Si se confunde mientras cambia de fases apague la electricidad por un minuto y pr ndala de nuevo Despu s del tiempo de calibraci n el control estar en fase AUTO MATICA 598 1163 01 S INSTALACION Para una f cil instalaci n escoja una luz con un interruptor de pared Montaje en pared Montaje en alero Para instalarlo bajo el alero la cabeza del detector debe ser girada como se muestra en los dos pasos siguientes para evitar el riesgo de un choque el ctrico S lo para montaje el ctrico O Gire la cabeza del detector hacia la uni n del tornillo sujetador _ Controles Tornillo Sujetador O Entonces gire la cabeza del detector hacia la derecha por 180 hasta que los controles miren hacia abajo Controles yw Controles Si el detector se sale de la uni n esf rica afloje el tornillo sujetador y empuje el detector hacia dentro de la uni n esf rica Apriete el tornillo sujetador cuando termine CONECTE EL CONTROL DE LUZ O Apague la e
5. e Hasta 70 pies 21 m varia de acuerdo a la temperatura que le rodea Hasta 180 Hasta 120 Vatios Maximo de luz incandescente Hasta 60 Vatios Maximo por cada portalamparas Hasta 40 Vatios Maximo de luz fluorescente Hasta 20 Vatios Maximo por cada portalamparas 120 V ca 60 Hz Angulo de sensibilidad Carga el ctrica Requisitos de potencia Modos de operaci n PRUEBA AUTOMATICO y MODO MANUAL Retardo de Tiempo 1 5 10 minutos Alcance Ajustable DESA Specialty Products se reserva el derecho de descontinuar productos y de cambiar especificaciones a cualquier momento sin incurrir en ninguna obligacion de tener que incorporar nuevas caracteristicas en los productos vendidos con anterioridad GUIA DE INVESTIGACION DE AVERIAS SINTOMA La Luz no se enciende La luz se prende durante el d a La luz se prende sin ninguna raz n aparente No est POSIBLE CAUSA 1 El interruptor de luz est apagado El faro est flojo o fundido El fusible est quemado o el cortacircuitos est apagado La desconexi n de luz del d a est en efecto Compru belo cuando comience la obscuridad Alambrado incorrecto si sta es una nueva instalaci n apuntando correctamente Apunte de nuevo el detector para proteger el rea deseada El Control de Luz puede estar instalado en un relativamente oscuro lugar El Co
6. e is recommended for best operation and performance when using compactfluorescent bulbs ON TIME 10 5 1 TEST MANUAL MODE Manual mode only works at night because daylight returns the sensor to AUTO Flip the light switch off for one second then back onto toggle between AUTO and MANUAL MODE 1 Second OFF then Manual mode works only with the ON TIME switch in the 1 5 or 10 position back on Mode Switching Summary Move ON TIME Switch to 1 5 or 10 minutes Flip light switch off for one second then back on MANUAL MODE If you get confused while switching modes turn the power off for one minute then back on After the calibration time the control will be in the AUTO mode 598 1163 01 INSTALLATION For easy installation select an existing light with a wall switch for replacement Wall Mount For under eave installation the sensor head must be rotated as shown in the next two steps for proper operation and to avoid the risk of electrical shock For eave mount only O Swing the sensor head towards the clamp screw joint Clamp Screw O Then rotate the sensor head clockwise 180 sothe controls face down I Controls Ifthe sensor pops out of the ball joint loosen the clamp screw and push the sensor back into the ball joint Tighten the clamp screw when done WIRE THE LIGHT CONTROL Turn power off at the fuse or circuit br
7. eaker Remove the existing light fixture O Installthe mounting strap as shown using two screws that fit your junction box O The plastic hanger can be used to hold the fixture while wiring The small end of the plastic hanger can be threaded through the hole in the center of the cover plate The small end then goes into one of the slots on the mounting strap O Route the Light Controls wires through the large gasket holes Twistthe junction box wires and fixture wires together as shown Secure with wire connectors Mounting Mounting Bolt Gasket Junction box ground wire to green ground screw on fixture MOUNT THE LIGHT CONTROL Align the Light Control cover plate and cover plate gasket Secure with the mounting bolt O Push the Rubber Plug firmly into place O Ifawetlocation junction box was not used caulk the wall plate mounting surface with silicone weather sealant Push Rubber Plug i i Lock Nut Firmly into Place l Holes for Lamp LS Cover Tabs Keep lamps at least 1 2 5 cm from the sen sor Do not allow the lampsto blockthe lens To avoid water damage and electrical shock keep lamp holders 30 below horizontal Lens O Adjust the lamp holders by loosening the lock nuts but do not rotate the lamp holders more than 180 from the factory setting When screwing in the lamps do not overtighten O Install the lamp covers Align the tabs on the lamp covers wit
8. eflejan la luz del d a pueden hacer que el detector se apague No apunte otras luces hacia el detector 180 4 Angulo de Cobertura Maxima 8 pies 2 4 m 70 pies 21 m Alcance Maximo El detector es menos sensible del movimiento que se dirige hacia el Lo menos sensible Movimiento r Detector Lo m s sensible 598 1163 01 O Afloje el tornillo sujetador en M Tornillo la uni n esf rica y gire gt Sujetador despacio el detector O Camine por el rea a Uni n protegerse y d se cuenta Esf rica d nde est cuando se prende la luz Mueva la cabeza del detector hacia arriba hacia abajo o hacia los lados para cambiar el rea de protecci n Apunte el Mantenga al detector por detector m s lo menos a 2 5 cm de arriba para las l mparas O Fije la sensibilidad SENS como necesite Demasiada sensibilidad puede aumentar las falsas alarmas mayor cobertura Apunte el detector hacia abajo para poca cobertura Asegure la punter a de la cabeza del detectorajustando el tornillo sujetador No lo apriete demasiado O Fije el per odo de tiempo ON TIME que la luz debe quedarse prendida despu s de detectar movimiento 1 56 10 minutos Nota No se recomienda el uso de la modalidad de un minuto con las bombillas fluorescentes compactas Advertencia Riesgo de incendio No apunte las l mparas a superficies combustibles dentro de un 1 metro ESPECIFICACIONES Alcanc
9. ge area Down for Short Keep the sensor at least 1 Coverage 2 5cm away fromthe lamps O Adjust the RANGE as needed RANGE set too high may increase false triggering Aim Sensor Secure the sensor head by Higher for Long tightening the clamp screw Coverage Do not overtighten the screw O Set the amount of TIME you want the lights to stay on after motion is detected 1 5 or 10 minutes Note One minute mode is not recommended for use with compact fluorescent bulbs Warning Risk of fire Do not aim the lamps at a combustible surface within 3 ft 1 m SPECIFICATIONS Range Up to 70 ft 21 m varies with surrounding temperature Sensing Angle Up to 180 Electrical Load Up to 120 Watts Maximum In candescent Up to 60 Watts Maximum each lamp holder Up to 40 Watts Maximum Fluo rescent Up to 20 Watts Maxi mum each lamp holder Power Requirements 120 VAC 60 Hz Operating Modes TEST AUTO and MANUAL MODE Time Delay 1 5 10 minutes Range Adjustable DESA Specialty Products reserves the right to dis continue products and to change specifications at any time without incurring any obligation to incorporate new features in products previously sold SYMPTOM Lights will not come on Lights come on in daylight Lights come on for TROUBLESHOOTING GUIDE Lights stay on continuously POSSIBLE CAUSE Light switch is turned off Flood ligh
10. h the holes on the lamp holders Gently press lamp covers until the tabs snap into the holes on the lamp holders 598 1163 01 TEST AND ADJUSTMENT O Turn on the circuit breaker and light switch NOTE Sensor has about 1 2 minutes warm up period before it will detect motion When first turned on wait about 1 2 minutes O Turnthe RANGE control to the mid position and the ON TIME control to the TEST position ON TIME A RANGE Fin wsitest HN OON 105 1 Test MIN MAX MAX MINUTES Bottom of Sensor Avoid aiming the control at Objects that change temperature rapidly such as heating vents and air conditioners These heat sources could cause false triggering Areas where pets or traffic may trigger the control Nearby large light colored objects reflecting light may trigger the shut off feature Do not point other lights at the sensor aN 8 ft 2 4 m 70 ft 21 m Maximum Range Maximum Coverage Angle The detector is most sensitive to motion across its field of view Sensor Least Sensitive Most Sensitive 598 1163 01 O Loosen the clamp screw in the sensor ball joint and gently ro tate the sensor O Walkthroughthe coverage area Clamp Screw Ball l Joint noting where you are when the lights turn on also the LED will flash several times when mo tion is detected Move the sen sor head up down orsideways Aim Sensor to change the covera
11. low this guide You may also want to visit our Web site at www desatech com If the problem persists call for assistance at 1 800 858 8501 7 30 AM to 4 30 PM CST M F You may also write to DESA Specialty Products P O Box 90004 Bowling Green KY 42102 9004 ATTN Technical Service Specialty Products If contacting Technical Service please have the following information available Model Number Date of Purchase and Place of Purchase No Service Parts Available for this Product TEN YEAR LIMITED WARRANTY This is a Limited Warranty which gives you specific legal rights You may also have other rights which vary from state to state or province to province For a period of ten years from the date of purchase any malfunction caused by factory defective parts or workmanship will be corrected at no charge to you To obtain a refund or a replacement call 1 800 858 8501 for instructions Not Covered Repair service adjustment and calibration due to misuse abuse or negligence light bulbs batteries and other expendable items are not covered by this warranty Unauthorized service or modification of the product or of any furnished component will void this warranty in its entirety This warranty does not include reimbursement for inconvenience installation setup time loss of use unauthorized service or return shipping charges This warranty covers only DESA Specialty Products assembled products and is not extended to other equip
12. ment and components that a customer uses in conjunction with our products THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING ANY WARRANTY REPRESENTATION OR CONDITION OF MERCHANT ABILITY OR THAT THE PRODUCTS ARE FIT FOR ANY PARTICULAR PURPOSE OR USE AND SPECIFICALLY IN LIEU OF ALL SPECIAL INDIRECT INCIDENTAL OR CONSEQUENTIAL DAMAGES REPAIR OR REPLACEMENT SHALL BE THE SOLE REMEDY OF THE CUSTOMER AND THERE SHALL BE NO LIABILITY ON THE PART OF DESA SPECIALTY PRODUCTS FOR ANY SPECIAL INDIRECT INCIDENTAL OR CONSEQUENTIAL DAMAGES INCLUDING BUT NOT LIMITED TO ANY LOSS OF BUSINESS OR PROFITS WHETHER OR NOT FORESEEABLE Some states or provinces do not allow the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you Proof of purchase is required for warranty claims 4 598 1163 01 Control de luz del detector de movimiento Modelo SH 5710 Caracter sticas Prende la luz cuando detecta movimiento Apaga la luz autom ticamente La fotoc lula mantiene la luz apagada durante el d a LED indica que se ha detectado movimiento durante el d a o la noche e Ahorros adicionales de energ a con las bombillas fluorescentes compactas Este paquete tiene Portal mparas Enchufe de caucho Colgador plastico L Detector cubertora IN EA Con
13. nerg a en el fusible o cortacircuitos O Quite el aparato de luz existente O Instale la l mina de montaje a la caja de empalme usandotornillos apropiados para la caja de empalme O Se puede usar el colgador pl stico para sostener el aparato mientras se instala el cableado El extremo peque o del colgador se puede pasar por el agujero en el centro de la placa cubertora El extremo peque o va luego dentro de las ranuras de la l mina de montaje O Pase todos los cables del aparato por los agujeros grandes del empaque como se muestra O Conecte los cables de la caja de empalme con los cables del aparato de luz como se muestra Tu razalos juntos y aseg relos con un conector de cables Blanco a Negro a Blanco Negro A 4 D l mina de Montaje Enchufe de Caucho Cable de a tierra de la caja de empalme al tornillo verde de a tierra del aparato INSTALE EL CONTROL DE LUZ Alinee la placa cubertora del Control de Luz con el empaque de la placa cubertora Asegure con el perno de montaje Empuje el tap n de caucho firmemente hasta que encaje Si no se us una caja de empalme para sitio mojado calafatee la superficie de montaje de la placa de pared con un sellador de silicona contra la intemperie y Q Q Ponga el tap n de caucho con firmeza en su sitio Contratuercas Agujeros para las aletas de las tapas de las l mparas Mantenga las lamparas por lo menosa2 5cmdel
14. ntrol de Luz est en fase de Prueba Fije el interruptor del controla la posici n de TIEMPO El Control de Luz puede estar detectando animales peque os o el tr sito de autom viles Reapunte el detector La luz se queda prendida continuamente La luz se prende y se apaga Unfaroest colocado demasiado cerca aldetectoro apunta a objetos cercanos que hace que el calor active el detector Reposicione la l mpara lejos del de tector o de los objetos cercanos El Control de Luz est apuntando hacia una fuente de calor tal como un conducto de aire de secadora o hacia una superficie con pintura brillante y que refleja el calor Reposicione el detector El control de luz esta en la Modo Manual Cambiela a Automatica El calor o la luz de las lamparas pueden estar prendiendo y apagando el Control de Luz Reposicione las lamparas lejos del detector Elcalor que se refleja de otros objetos puede estar afectando al detector Reposicione el detector El Control de Luz est en fase de Prueba y calent ndose El prenderse y apagarse es normal bajo estas condiciones La Sensibilidad es demasiado alta Reduzca la sensibilidad SERVICIO T CNICO No enviar los productos Si tiene alg n problema por favor siga esta gu a Lo sentimos pero no podemos contestar preguntas en espa ol por tel fono Usted puede tambi n escribir a DESA Specialty Products P O B
15. ox 90004 Bowling Green KY 42102 9004 Si se llama al Servicio T cnico por favor tener lista la siguiente informaci n N mero de Modelo Fecha de compra y Lugar de compra No hay piezas de servicio disponibles para este producto GARANT A LIMITADA A 10 A OS Esta es una Garant a Limitada que le da a Ud derechos legales espec ficos Usted puede tambi n tener otros derechos que var an de estado a estado o de provincia a provincia Por un per odo de 10 a os desde la fecha de compra cualquier mal funcionamiento ocasionado por partes defectuosas de f brica o mano de obra ser corregido sin cargo para Ud Para obtener el reembolso o reemplazo llame al 1 800 858 8501 y pida instrucciones No cubierto Servicio de reparaci n ajuste y calibraci n debido al mal uso abuso o negligencia bombillas bater as u otras partes fungibles no est n cubiertas por esta garant a Los Servicios no autorizados o modificaciones del producto o de cualquier componente que se provee invalidar n esta garant a en su totalidad Esta garant a no incluye reembolso por inconveniencia instalaci n tiempo de instalaci n perdida de uso servicio no autorizado o costos de transporte de retorno Esta garant a cubre solamente los productos ensamblados por DESA Specialty Products y no se extiende a otros equipos o componentes que el consumidor usa junto con nuestros productos ESTA GARANT A EST EXPRESAMENTE EN LUGAR DE OTRAS GARANT AS EXPRESAD
16. t is loose or burned out Fuse is blown or circuit breaker is turned off Daylight turn off is in effect re check after dark Incorrect circuit wiring if this is a new installation Re aim the sensor to cover de sired area Light Control may be installed in a relatively dark location Light Control is in Test Set control switch to an ON TIME position Light Control may be sensing small animals or automobile traf Lights flash on and off POSSIBLE CAUSE Aflood lamp is positioned too close to the sensor or pointed at nearby ob jects that cause heat to trigger the sensor Reposition the lamp away from the sensor or nearby objects Light Control is pointed toward a heat source like an air vent dryer vent or brightly painted heat reflective sur face Reposition sensor Light Control is in Manual Mode Switch to Auto Heat or light from the lamps may be turning the Light Control on and off Reposition the lamps away from the sensor Heat being reflected from other ob jects may be affecting the sensor Reposition sensor no apparent rea son fic re aim sensor Range is set too high Reduce Range Light Control is in the Test mode and warming up Flashing is normal un der these conditions TECHNICAL SERVICE Please call 1 800 858 8501 for assistance before returning product to store If you experience a problem fol
17. trol de luz Cu 2 conectores de alambre 1 perno L mina de montaje amma Empaque 2 Bombillas 6 tornillos 3 dimensiones fluorescentes compactas Requisitos El Control de Luz requiere 120 VCA Para usar el Sobrecontrol Manual conecte el control con un interruptor Algunos c digos requieren instalaci n por un electricista calificado Se recomienda usar este producto con el empaque provisto y con una caja de empalme marcada para uso en lugares h medos Nota No se recomienda usar este producto en lugares donde la temperatura externa es de 10 F 2004 DESA Specialty Products FUNCIONAMIENTO Modalidad tiempo encendido Trabaja Dia Noche Prueba 5se x xo Autom 1 5610mn x lll MEN amanecer Se pone en Autom tico al amanecer Nota Cuando lo prenda por primera vez espere 1 1 2 minutos para que el circuito se claibre Para PRUEBA Ponga el interruptor de tiempo ON ON TIME TIME al fondo del detector en la posici n de prueba TEST 1051 TEST Para AUTOMATICO Ponga el interruptor de tiempo ON TIME en la posici n de 1 5610 minutos Nota Aunque se puede usar la modalidad de 1 minuto se recomienda la de 5 10 minutos para obtener el mejorfuncionamiento y rendimiento cuando se usen bombillas fluorescentes compactas Para MODO MANUAL ON TIME 1051 TEST El modo manual funciona s lo por la noche porque la luz del d a pone al mu detector en modo