Dell PowerEdge C6145 Getting Started Guide
Contents
1. Press the power button s either on the front or back of the system and on the monitor The power indicators on the front should light Getting Started With Your System 8 Es NOTE The color of the power indicator on the monitor will vary with the different monitor models Complete the Operating System Setup To install an operating system for the first time see the installation and configuration documentation for your operating system Be sure the operating system is installed before installing hardware or software not purchased with the system 4 NOTE For the latest information on supported operating systems see dell com ossupport Other Information You May Need WARNING See the safety and regulatory information that shipped with your system Warranty information may be included within this document or as a separate document The Hardware Owner s Manual provides information about system features and describes how to troubleshoot the system and install or replace system components This document is available at dell com support manuals Dell systems management application documentation provides information about installing and using the systems management software This document is available online at dell com support manuals K NOTE Always check for updates on dell com support manuals and read the updates first because they often supersede information in other documents Getting Started With Your
2. Environmental NOTE For additional information about environmental measurements for specific system configurations see www dell com environmental_datasheets Temperature Operating 10 to 35 C 50 to 95 F with a maximum temperature gradation of 10 C per hour NOTE For altitudes above 2950 feet the maximum operating temperature is derated 1 F 550 ft NOTE For AMD 6180SE 140W processor the maximum operating temperature is up to 30 C 86 F Storage 40 to 65 C 40 to 149 F with a maximum temperature gradation of 20 C per hour Relative humidity Operating 20 to 80 noncondensing with a maximum humidity gradation of 10 per hour Storage 5 to 95 noncondensing Maximum vibration Operating 0 26 Grms at 5 350 Hz Storage 1 88 Grms at 10 500 Hz for 15 min Getting Started With Your System 13 Maximum shock Operating One shock pulse in the positive z axis one pulse on each side of the system of 31 G for 2 6 ms in the operational orientation Storage Six consecutively executed shock pulses in the positive and negative x y and z axes one pulse on each side of the system of 71 G for up to 2 ms Six consecutively executed shock pulses in the positive and negative x y and z axes one pulse on each side of the system of 22 G faired square wave pulse with velocity change at 200 inches second 508 centimeters second Altitude Operating 16 to 3 048 m 50 to 10 000 ft NOTE For altitu
3. K NOTA Os trilhos podem ser usados em rack de orif cio retangular tem 1 na figura a seguir e redondo item 2 na figura a seguir Figura 1 Pressionar os bot es de libera o da trava Vista frontal 3 Repita etapa 1 e a etapa 2 para posicionar e instalar as extremidades frontais nos flanges verticais FA NOTA Para remover os trilhos pressione o bot o de libera o da trava nos pontos do meio da pe a de extremidade e desencaixe o trilho 4 Em cada guia vertical do rack na parte traseira insira duas bases de parafusos nos dois orif cios retangulares logo acima do trilho 5 Instale os suportes estabilizadores do chassi opcionais nos flanges traseiros do rack e simultaneamente aperte os parafusos E NOTA Para transportar sistemas j instalados no rack verifique se os dois suportes de envio de estabiliza o do chassi opcionais est o no lugar cert Introdu o ao Uso do Sistema 32 Figura 2 Instala o dos suportes estabilizadores do chassi Vista traseira DASNSDRDODODO 6 Deslize o sistema sobre o rack 7 Aperte os parafusos de aperto manual para prender as abas do sistema aos flanges do rack Figura 3 Instalac o do chassis no rack Vista traseira Vista frontal Introdu o ao Uso do Sistema 33 Opcional Conectar o teclado o mouse e o monitor Figura 4 Optional Conex o do teclado mouse e monitor Conecte o teclado o mouse e
4. Tipo de barramento Slots de expans o PCle Placa PCle filha PCI Express de segunda gera o Um MDI de baixo perfil x16 largura m xima de 4 795 polegadas 12 cm Dois MD2 de baixo perfil x16 largura m xima de 6 674 inches 17 cm Um slot mezanino x16 Mem ria por placa de sistema Arquitetura Soquetes de m dulos de mem ria Capacidades dos m dulos de mem ria 32 UDIMMs ou RDIMMs DDR3 de 1066 1333 1600 MHz 32 soquetes DIMM DDR3 2 GB 4 GB 8 GB 16 GB ou 32 GB Minimo de RAM 64 GB M ximo de RAM 1024 GB Unidades Discos r gidos Introdu o ao Uso do Sistema 38 At doze unidades SAS SATA de 3 5 polegadas com troca a quente ou at vinte e quatro unidades SAS SATA SSD de 2 5 polegadas com troca a quente NOTA Os discos r gidos SAS s o suportados por uma placa complementar Conectores por placa de sistema Traseiros Placa de rede Serial USB Video Porta de gerenciamento Conector iPass Interno Soquete Micro SD Dois conectores Ethernet RJ 45 10 100 1000 Mbps DTE de 9 pinos compativel com 16550 Dois de 4 pinos compativeis com USB 2 0 VGA D Sub de 15 pinos Porta Ethernet dedicada para acesso de gerenciamento remoto Conex o a dispositivos PCIE externos ou a uma porta de extensor de barramento PCIE Soquete de mem ria de placa riser SD V deo por placa de sistema Tipo de v deo Mem ria de v deo Controlador de v
5. et XenServer sont des marques d pos es ou des marques de Citrix Systems Inc aux tats Unis et ou dans d autres pays VMware est une marque d pos e ou une marque de VMware Inc aux tats Unis ou dans d autres pays D autres marques et noms de marque peuvent tre utilis s dans ce document pour faire r f rence aux entit s se r clamant de ces marques et de ces noms ou de leurs produits Dell Inc rejette tout int r t propri taire dans les marques et les noms de marques autres que les siens Mod le r glementaire B05S Septembre 2013 N P 6HNH8 R v A04 A PR CAUTION lieux acc s restreint Ce serveur est con u pour tre install uniquement dans des zones acc s restreint telles que d finies par la consigne CI 1 2 7 3 de la norme IEC 60950 1 2001 o les deux conditions suivantes s appliquent Seuls peuvent avoir acc s le personnel d entretien et les utilisateurs qui ont t inform s des motifs des restrictions appliqu es au lieu et des pr cautions prendre L acc s qui se fait par l interm diaire d un outil ou d un verrou et d une cl ou par d autres moyens de s curit est contr l par le responsable en charge du lieu Installation et configuration AVERTISSEMENT avant de commencer la proc dure suivante lisez et respectez les consignes de s curit fournies avec le syst me D ballage du syst me Sortez le syst me de son emballage et identifiez chaque l ment Ins
6. Procedimientos iniciales con el sistema 52 Informaci n de la NOM s lo para M xico La informaci n que se proporciona a continuaci n aparece en el dispositivo descrito en este documento en cumplimiento de los requisitos de la Norma Oficial Mexicana NOM Importador Dell Inc de M xico S A de C V Paseo de la Reforma 2620 11 Piso Col Lomas Atlas 11950 M xico D F N mero de modelo BO5S Voltaje de alimentaci n Unidad de suministro de alimentaci n de 100 240 V CA con 1100 W Unidad de suministro de alimentaci n de 200 240 V CA con 1400 W Frecuencia 50 60 Hz Consumo el ctrico Unidad de suministro de alimentaci n de 12 6 7 Amps con 1100 W Unidad de suministro de alimentaci n de 8 6 Amps con 1400 W Especificaciones t cnicas Procesador por placa base Tipo de procesador Cuatro procesadores AMD Opteron serie 6100 O cuatro procesadores AMD Opteron serie 6200 O cuatro procesadores AMD Opteron serie 6300 Bus de expansi n por placa base Tipo de bus PCI Express de segunda generaci n Ranuras de expansi n PCle Una x16 de perfil MDI bajo longitud m xima de 12 18 cm Procedimientos iniciales con el sistema 53 Tarjeta secundaria PCIe Dos x16 de perfil MD2 bajo longitud m xima de 16 95 cm Una ranura x16 para tarjetas intermedias Memoria por placa base Arquitectura Z calos de m dulo de memoria Capacidades de m dulo de memoria 32 x UDIMM o RDIMM D
7. o ADVERT NCIA Antes de executar o procedimento a seguir leia e siga as instru es de seguran a fornecidas com o sistema Remover o sistema da embalagem Remova o sistema da embalagem e identifique cada item Como instalar a solu o de trilhos sem ferramentas DA ADVERT NCIA Sempre que precisar levantar o sistema solicite a ajuda de outras pessoas Para evitar ferimentos n o tente levant lo por conta pr pria ADVERT NCIA O sistema n o preso ao rack nem montado nos trilhos Para evitar les es pessoais e danos ao sistema apoie o rack do sistema de modo adequado durante a instalac o ou remoc o ADVERT NCIA Para evitar poss veis riscos de choque el trico necess rio usar um condutor de seguran a aterrado na instala o do rack O equipamento do rack deve fornecer ventila o suficiente para que o sistema mantenha o grau de refrigera o adequado AVISO Ao instalar os trilhos em um rack de orif cio retangular importante garantir que o pino retangular deslize pelos orif cios retangulares gt gt Introdu o ao Uso do Sistema 31 1 Pressione os bot es de libera o da trava dos pontos do meio da pe a de extremidade para abrir as travas do trilho 2 Alinhe as extremidades traseiras dos trilhos nas guias verticais do rack para instalar os pinos no orif cio inferior do primeiro U e no orif cio superior do segundo U e prenda a extremidade traseira do trilho at encaixar as travas
8. qualquer hardware ou software que n o tenha sido adquirido com o sistema K NOTA Para obter as informa es mais recentes sobre os sistemas operacionais compat veis consulte o site dell com ossupport Outras informa es teis ADVERT NCIA Consulte as informa es sobre normaliza o e seguran a fornecidas com o sistema As informa es de garantia podem estar inclu das neste documento ou podem ser fornecidas como um documento separado O Manual do propriet rio de hardware fornece informa es sobre os recursos do sistema e descreve como solucionar problemas do sistema e instalar ou trocar componentes Este documento est dispon vel em dell com support manuals A documenta o do aplicativo de gerenciamento de sistemas Dell fornece informa es sobre como instalar e usar o software de gerenciamento de sistemas Este documento est dispon vel on line em dell com support manuals K NOTA Verifique sempre se h atualiza es no site dell com support manuals e leia primeiro as informa es sobre as atualiza es pois elas quase sempre substituem as informa es de outros documentos Introdu o ao Uso do Sistema 37 Especifica es t cnicas Processador por placa de sistema Tipo de processador Quatro processadores AMD Opteron s rie 6100 Ou quatro processadores AMD Opteron s rie 6200 Ou quatro processadores AMD Opteron s rie 6300 Barramento de expans o por placa de sistema
9. Figure 1 Appui sur les boutons d ouverture des loquets Vue avant 3 R p tez l tape 1 et l tape 2 afin de positionner et fixer les embouts avant des rails sur les montants verticaux K REMARQUE pour retirer les rails tirez sur le bouton d ouverture du loquet situ au milieu de l unit d extr mit et d gagez chaque rail 4 l arri re de chaque montant vertical du rack ins rez deux vis dans les deux trous carr s situ s juste au dessus du rail 5 Installez les supports de stabilisation du ch ssis qui vous ont t livr s en option sur les collerettes du rail arri re tout en serrant les vis K REMARQUE avant de transporter des syst mes d j install s dans le rack assurez vous que les deux supports d exp dition du stabilisateur de ch ssis en option sont en place Guide de mise en route du syst me 18 Figure 2 Appui sur les boutons d ouverture des loquets AN Vue arri re 7 Le Le A La A A A L gt NS ANS TA 6 Glissez le syst me dans le rack 7 Serrez les vis serrage main afin de fixer les pattes du syst me l avant des montants du rack Figure 3 Installation du ch ssis dans le rack EVue arri re Vue avant Guide de mise en route du syst me 19 Facultatif Connexion du clavier de la souris et du moniteur Figure 4 Facultatif Connexion du clavier de la souris et du moniteur Connectez le clavi
10. Pour une premi re installation du syst me d exploitation consultez la documentation relative son installation et sa configuration Veillez installer le syst me d exploitation avant tout l ment mat riel ou logiciel achet s par ment K REMARQUE pour obtenir les derni res informations sur les syst mes d exploitation pris en charge rendez vous sur le site dell com ossupport Autres informations utiles A AVERTISSEMENT voir les informations sur la s curit et les r glementations qui accompagnent votre syst me Les informations sur la garantie se trouvent dans ce document ou dans un document distinct Le document Hardware Owner s Manual Manuel du propri taire contient des informations sur les caract ristiques du syst me ainsi que des instructions relatives au d pannage et l installation ou au remplacement de composants Ce document est disponible l adresse support dell com manuals La documentation relative aux applications de gestion de syst mes Dell donne des informations sur l installation et l utilisation du logiciel de gestion de syst mes Ce document est disponible l adresse support dell com manuals EZ REMARQUE recherchez toujours les mises jour sur dell com support manuals et consultez les en premier car elles remplacent souvent les informations qui se trouvent dans d autres documents Guide de mise en route du syst me 23 Caract ristiques techniques Processeur par cart
11. deo AST2050 integrado 8 MB Alimenta o Fonte de alimenta o CA por fonte de alimenta o Pot ncia Tens o Dissipa o de calor Pot ncia Tens o Dissipa o de calor 1023 W linha baixa 1100 W linha alta 100 a 240 VCA 50 a 60 Hz corrente de entrada m xima 12 0 A 4217 BTU h no m ximo 1400 W 200 a 240 VCA 50 a 60 Hz corrente de entrada m xima 8 6 A 5724 BTU h no m ximo Introdu o ao Uso do Sistema 39 Pico m ximo de corrente inicial Baterias por placa de sistema Bateria do sistema Bateria RAID opcional Caracter sticas f sicas O pico de corrente inicial n o pode exceder 55 A O pico de corrente inicial secund rio n o pode exceder 35 A Bateria tipo moeda de ons de l tio CR 2032 de 3 0 V Bateria de ons de l tio de 3 7 V Altura Largura Profundidade Peso configura o m xima Peso vazio 8 76 cm 3 45 polegadas 44 8 cm 17 6 polegadas 79 0 cm 31 1 polegadas 42 kg 92 61 libras 16 5 kg 36 38 libras Requisitos ambientais NOTA Para obter informa es adicionais sobre os requisitos ambientais para configura es espec ficas do sistema visite o site www dell com environmental datasheets em ingl s Temperatura De opera o De armazenamento Umidade relativa De opera o De armazenamento Introdu o ao Uso do Sistema 40 10 C a 35 C 50 Fa 95 F com varia o m xima de 10 C por hor
12. o monitor opcional Os conectores na parte de tr s do sistema possuem cones indicando quais cabos devem ser ligados a cada conector Certifique se de apertar os parafusos se houver no conector do cabo do monitor Introdu o ao Uso do Sistema 34 Conectar o s cabo s de alimenta o Figura 5 Conex o do cabo de alimenta o Conecte o s cabo s de alimenta o ao sistema e se for usado um monitor conecte o cabo de alimenta o do monitor Conecte a outra extremidade dos cabos de alimenta o a uma tomada el trica aterrada ou a uma fonte de energia separada por exemplo uma fonte de alimenta o ininterrupta ou uma unidade de distribui o de energia Introdu o ao Uso do Sistema 35 Como ligar o sistema Figura 6 Pressionar o bot o liga desliga na parte frontal do sistema e do monitor 1 AA Pressione o s bot o es liga desliga localizado na parte frontal ou traseira do sistema e do monitor Os indicadores de alimenta o na parte frontal devem acender Introdu o ao Uso do Sistema 36 E NOTA A cor do indicador de for a no monitor pode variar de acordo com o modelo do monitor Concluir a configurac o do sistema operacional Para instalar um sistema operacional pela primeira vez consulte a documenta o de instala o e configura o do sistema operacional Certifique se de que o sistema operacional esteja instalado antes de instalar
13. removal WARNING To avoid a potential electrical shock hazard a third wire safety grounding conductor is necessary for the rack installation The rack equipment must provide sufficient airflow to the system to maintain proper cooling CAUTION When installing rails in a square hole rack it is important to ensure that the square peg slides through the square holes Getting Started With Your System 3 1 Pull on the latch release buttons on the midpoints of the end piece to open the rail latches 2 Align the end pieces of the rails on the vertical rack flanges to seat the pegs in the bottom hole of the first U and the top hole of the second U Engage the back end of the rails until the latches lock in place K NOTE The rails can be used in both square hole item 1 in the following figure and round hole racks item 2 in the following figure Figure 1 Pushing the Latch Release Buttons Front View 3 Repeat Step 1 and Step 2 to position and seat the front end pieces on the vertical flanges K NOTE To remove the rails pull on the latch release button on the midpoints of the end piece and unseat each rail 4 On each vertical rack flange on the back put two screw bases into the two square holes right above the rail 5 Install the chassis stabilizer shipping brackets optional on the back rack flanges and simultaneously tighten the screws K NOTE To transport systems already installed in the rack ensure that th
14. ximo 1400 W 200 240 V CA 50 60 Hz corriente m xima de entrada 8 6 A 5724 BTU h 1676 W como m ximo La corriente de conexi n inicial no puede superar los 55 A pico La corriente de conexi n secundaria no puede superar los 35 A pico Bater a de tipo bot n de litio ion de 3 0 V CR2032 Bater a litio ion de 3 7 V Caracter sticas f sicas Altura 8 76 cm Anchura 44 8 cm Profundidad 79 0 cm Peso configuraci n m xima 42 kg Peso vac o 16 5 kg Procedimientos iniciales con el sistema 55 Especificaciones ambientales NOTA Para obtener informaci n adicional sobre medidas ambientales relativas a configuraciones de sistema espec ficas visite www dell com environmental datasheets Temperatura En funcionamiento En almacenamiento Humedad relativa En funcionamiento En almacenamiento Vibraci n m xima En funcionamiento En almacenamiento Impacto m ximo En funcionamiento En almacenamiento Procedimientos iniciales con el sistema De 10 C a 35 C con una gradaci n de temperatura m xima de 10 C por hora NOTA Para altitudes superiores a 900 m la temperatura m xima de funcionamiento se reduce 1 C cada 300 m NOTA Para el procesador AMD 6180SE 140W la temperatura m xima de funcionamiento es de 30 C De 40 a 65 C con una gradaci n de temperatura m xima de 20 C por hora Del 20 al 80 sin condensaci n con una gradaci n de humedad m xim
15. C mo presionar los botones del pasador de liberaci n Vista anterior 3 Repita el paso 1 y el paso 2 para colocar y encajar los extremos frontales en las pesta as verticales K NOTA Para extraer los rieles tire del bot n del pasador de liberaci n en los puntos medios de la pieza en el extremo y extraiga cada riel 4 En cada pesta a vertical de la parte posterior coloque dos bases de tornillo en los dos orificios cuadrados justo encima del riel Procedimientos iniciales con el sistema 46 5 Instale los soportes de env o del estabilizador del chasis opcional en las bridas del bastidor posterior y a la vez apriete los tornillos E NOTA Para transportar sistemas que ya est n instalados en el rack aseg rese de que los dos soportes de transporte para estabilizaci n del chasis opcionales se encuentren en su lugar Ilustraci n 2 Instalaci n de los soportes de env o del estabilizador del chasis Vista posterior 7 A A a Lt a Le ES e d 7 SY SEX Procedimientos iniciales con el sistema 47 6 Inserte el sistema en el rack 7 Apriete los tornillos mariposa para fijar las pesta as del sistema a la parte frontal de las pesta as del rack Ilustraci n 3 Instalaci n del chasis en el bastidor i Vista posterior Vista anterior Procedimientos iniciales con el sistema 48 Opcional Conexi n del teclado el rat n y el monitor Ilustraci n 4 O
16. DR3 de 1066 1333 1600 MHz 32 z calos DIMM DDR3 2 GB 4 GB 8 GB 16 GB o 32GB RAM minimo 64 GB RAM m ximo 1024 GB Unidades Unidades de disco duro Hasta 12 unidades SAS SATA de intercambio activo de 3 5 pulgadas o hasta 24 unidades SAS SATA SSD de intercambio activo de 2 5 pulgadas NOTA Las unidades de disco duro SAS se admiten mediante tarjeta adicional Conectores por placa base Parte posterior NIC Serie USB V deo Puerto de administraci n iPass connector Procedimientos iniciales con el sistema Dos RJ 45 Ethernet 10 100 1000 Mbps 9 patas DTE compatible con 16550 Dos de 4 patas compatibles con USB 2 0 VGA D Sub de 15 patas Puerto Ethernet dedicado para el acceso a la administraci n remota Conexi n a dispositivos PCIE externos o a un puerto de bus extender PCIE 54 Parte interna Z calo Micro SD Z calo de memoria de la tarjeta vertical SD Video por placa base Tipo de video Memoria de video Controladora de video AST2050 integrada 8 MB Alimentaci n Fuente de alimentaci n de CA por fuente de alimentaci n Potencia Voltaje Disipaci n de calor Potencia Voltaje Disipaci n de calor Corriente de conexi n m xima Bater a por placa base Bater a del sistema Bater a RAID opcional 1023 W en baja 1 100 W en alta 100 240 V CA 50 60 Hz corriente m xima de entrada 12 0 A 4217 063 BTU h 1 235 W como m
17. Dell PowerEdge C6145 Getting Started With Your System Guide de mise en route du syst me Introdu o ao Uso do Sistema Procedimientos iniciales con el sistema Dell PowerEdge C6145 Getting Started With Your System Notes Cautions and Warnings Es NOTE A NOTE indicates important information that helps you make better use of your computer A CAUTION A CAUTION indicates potential damage to hardware or loss of data if instructions are not followed AN WARNING A WARNING indicates a potential for property damage personal injury or death Information in this document is subject to change without notice 2013 Dell Inc All rights reserved Reproduction of these materials in any manner whatsoever without the written permission of Dell Inc is strictly forbidden Trademarks used in this text Dell the DELL logo and PowerEdge are trademarks of Dell Inc AMD is a registered trademark and AMD Opteron is a trademark of Advanced Micro Devices Inc Red Hat Enterprise Linux and Enterprise Linux are registered trademarks of Red Hat Inc in the United States and or other countries Novell is a registered trademark and SUSE is a trademark of Novell Inc in the United States and other countries Citrix and XenServer are either registered trademarks or trademarks of Citrix Systems Inc in the United States and or other countries VMware is a registered trademarks or trademarks of VMWare Inc in the United
18. ISA S71 04 1985 Introdu o ao Uso do Sistema 41 Introdu o ao Uso do Sistema 42 Dell PowerEdge C6145 Procedimientos iniciales con el sistema Notas precauciones y avisos K NOTA Una NOTA proporciona informaci n importante que le ayudar a utilizar mejor el ordenador A PRECAUCI N Un mensaje de PRECAUCI N indica la posibilidad de da os en el hardware o la p rdida de datos si no se siguen las instrucciones A AVISO Un mensaje de AVISO indica el riesgo de da os materiales lesiones o incluso la muerte La informaci n contenida en este documento puede modificarse sin previo aviso O 2013 Dell Inc Todos los derechos reservados Queda estrictamente prohibida la reproducci n de este material en cualquier forma sin la autorizaci n por escrito de Dell Inc Marcas comerciales utilizadas en este texto Dell el logotipo de DELL y PowerEdge son marcas comerciales de Dell Inc AMD es una marca comercial registrada y AMD Opteron es una marca comercial de Advanced Micro Devices Inc Red Hat Enterprise Linux y Enterprise Linux son marcas comerciales registradas de Red Hat Inc en los Estados Unidos o en otros pa ses Novell es una marca comercial registrada y SUSETM es una marca comercial de Novell Inc en los Estados Unidos y en otros paises Citrix y XenServer son marcas comerciales o marcas comerciales registradas de Citrix Systems Inc en los Estados Unidos o en otros pa ses VMware es
19. States or other countries Other trademarks and trade names may be used in this publication to refer to either the entities claiming the marks and names or their products Dell Inc disclaims any proprietary interest in trademarks and trade names other than its own Regulatory Model B05S September 2013 P N 6HNH8 Rev A04 A CAUTION Restricted Access Location This server is intended for installation only in restricted access locations as defined in Cl 1 2 7 3 of IEC 60950 1 2001 where both these conditions apply Access can only be gained by service persons or by users who have been instructed about the reasons for the restrictions applied to the location and about any precautions that shall be taken Access is through the use of a tool or lock and key or other means of security and is controlled by the authority responsible for the location Installation and Configuration WARNING Before performing the following procedure review and follow the safety instructions that came with the system Unpacking the System Unpack your system and identify each item Installing the Tool Less Rail Solution gt EEE WARNING Whenever you need to lift the system get others to assist you To avoid injury do not attempt to lift the system by yourself WARNING The system is not fixed to the rack or mounted on the rails To avoid personal injury or damage to the system you must adequately support the system during installation and
20. System 9 NOM Information Mexico Only The following information is provided on the device described in this document in compliance with the requirements of the official Mexican standards NOM Importer Model number Supply voltage Frequency Current consumption Getting Started With Your System Dell Inc de M xico S A de C V Paseo de la Reforma 2620 11 Piso Col Lomas Atlas 11950 M xico D F BOSS 100 240 V CA with 1100 W Power Supply Unit 200 240 V CA with 1400 W Power Supply Unit 50 60 Hz 12 6 7 Amps with 1100 W Power Supply Unit 8 6 Amps with 1400 W Power Supply Unit Technical Specifications Processor Per System Board Processor type Four AMD Opteron 6100 Series processors Or four AMD Opteron 6200 Series processors Or four AMD Opteron 6300 Series processors Expansion Bus Per System Board Bus type Expansion slots PCIe Daughter card PCle PCI Express Generation 2 One x16 low profile MD1 maximum length 4 795 inches Two x16 low profile MD2 maximum length 6 674 inches One x16 Mezzanine slot Memory Per System Board Architecture Memory module sockets Memory module capacities 32 x DDR3 1066 1333 1600 MHz RDIMM or UDIMM 32 x DDR3 DIMM sockets 2 GB 4 GB 8 GB 16 GB or 32GB Minimum RAM 64 GB Maximum RAM 1024 GB Drives Hard drives Up to twelve 3 5 inch hot swappable SAS SATA drives or up to twenty four 2 5 inch h
21. a NOTA Para altitudes acima de 900 m 2 950 p s a temperatura m xima de opera o diminui raz o de 1 C 300 m 1 F 550 p s NOTA Para o processador AMD 6180SE 140W a temperatura m xima de opera o de 30 C 86 F 40 a 65 C 40 a 149 F com varia o m xima de 20 C por hora 20 a 80 sem condensa o com varia o m xima de 10 por hora 5 a 95 sem condensa o Vibra o m xima De opera o De armazenamento Choque m ximo De opera o De armazenamento Altitude De opera o De armazenamento 0 26 g RMS a 5 350 Hz 1 88 g RMS em 10 a 500 Hz por 15 min Um pulso de choque no eixo z positivo um pulso de cada lado do sistema de 31 g por 2 6 ms na orienta o operacional Seis pulsos de choque aplicados consecutivamente nos eixos x y Z positivos e negativos um pulso de cada lado do sistema de 71 G por at 2 ms Seis pulsos de choque aplicados consecutivamente nos eixos x y Z positivos e negativos um pulso de cada lado do sistema de onda quadrada de 22 g com varia o de velocidade de 200 polegadas segundo 508 centimetros segundo 16 a 3 048 m 50 a 10 000 p s NOTA Para altitudes acima de 900 m 2 950 p s a temperatura m xima de opera o diminui raz o de 1 C 300 m 1 F 550 p s 16 a 10 600 m 50 a 35 000 p s Nivel de poluentes transportados pelo ar Classe G2 ou inferior conforme definido pela norma
22. a ayuda de otros Con el fin de evitar lesiones personales no intente levantar el sistema usted solo AVISO El sistema no est fijado al rack ni montado en los rieles Para evitar lesiones personales o da os en el sistema debe sujetar adecuadamente el sistema durante la instalaci n y la extracci n AVISO Para evitar que se produzca una descarga el ctrica es necesario que la instalaci n del rack cuente con un tercer conductor de conexi n a tierra El equipo del rack debe proporcionar el suficiente flujo de aire al sistema para mantener una refrigeraci n adecuada PRECAUCI N A la hora de instalar rieles en un rack con orificios cuadrados es importante comprobar que la espiga cuadrada se desliza correctamente a trav s de los orificios cuadrados Procedimientos iniciales con el sistema 45 1 Tire de los botones del pasador de liberaci n en los puntos medios de la pieza en el extremo para abrir los seguros de los rieles 2 Alinee los extremos de los rieles de las pesta as verticales del rack para insertar las espigas en el orificio inferior de la primera posici n U y en el orificio superior de la segunda posici n U Apriete el extremo posterior de los rieles hasta que los pestillos se asienten en su lugar K NOTA Los rieles pueden utilizarse tanto en racks con orificios cuadrados elemento 1 de la siguiente ilustraci n como en racks con orificios redondos elemento 2 de la siguiente ilustraci n Ilustraci n 1
23. a de 10 por hora Del 5 al 95 sin condensaci n 0 26 Grms a 5 350 Hz 1 88 Grms a 10 500 Hz durante 15 minutos Un choque en el sentido positivo del eje z un choque en cada lado del sistema de 31 G durante 2 6 ms en la orientaci n de funcionamiento Seis choques ejecutados consecutivamente en el sentido positivo y negativo de los ejes x y y z un choque en cada lado del sistema de 71 G durante un m ximo de 2 ms Seis choques ejecutados consecutivamente en los ejes x y y Z positivo y negativo un choque en cada lado del sistema de onda cuadrada alisada de 22 G con cambio de velocidad a 508 cm s 56 Altitud En funcionamiento De 16 a 3048 m NOTA Para altitudes superiores a 900 m la temperatura m xima de funcionamiento se reduce de 1 C cada 300 m En almacenamiento De 16 a 10 600 m Nivel de contaminaci n atmosf rica Clase G2 o menos de acuerdo con ISA S71 04 1985 Procedimientos iniciales con el sistema 57 Procedimientos iniciales con el sistema 58 Printed in Brazil Imprim au Br sil Impresso no Brasil Impreso en Brasil www dell com support dell com O6HNH8A04 Printed in the U S A Imprim aux U S A Impresso nos EUA Impreso en los EE UU www dell com support dell com O6HNH8A04
24. des above 2950 feet the maximum operating temperature is derated 1 F 550 ft Storage 16 to 10 600 m 50 to 35 000 ft Airborne contaminant level Class G2 or lower as defined by ISA S71 04 1985 Getting Started With Your System 14 Dell PowerEdge C6145 Guide de mise en route du syst me Remarques pr cautions et avertissements EZ REMARQUE une REMARQUE indique des informations importantes qui peuvent vous aider mieux utiliser votre ordinateur IN PR CAUTION une PR CAUTION indique un risque d endommagement du mat riel ou de perte de donn es en cas de non respect des instructions A AVERTISSEMENT un AVERTISSEMENT indique un risque d endommagement du mat riel de blessure corporelle ou de mort Les informations contenues dans ce document sont sujettes modification sans pr avis O 2013 Dell Inc tous droits r serv s La reproduction de ce document de quelque mani re que ce soit sans l autorisation crite de Dell Inc est strictement interdite Marques utilis es dans le pr sent document Dell le logo DELL et PowerEdge sont des marques de Dell Inc AMD est une marque d pos e et AMD Opteron est une marque d Advanced Micro Devices Inc Red Hat Enterprise Linux et Enterprise Linux sont des marques d pos es de Red Hat Inc aux tats Unis et ou dans d autres pays Novell est une marque d pos e et SUSETM est une marque de Novell Inc aux tats Unis et dans d autres pays Citrix
25. e Connexion p riph riques externes PCIE ou un port PCIE bus extender Support de carte de montage de m moire SD Vid o par carte syst me Type de vid o M moire vid o Contr leur vid o int gr AST2050 8 Mo Alimentation Alimentation en CA par bloc d alimentation Puissance Tension Dissipation thermique Puissance Tension Dissipation thermique Courant d appel maximal 1 023 W basse tension 1 100 W haute tension 100 240 V CA 50 60 Hz courant maximum en entr e 12 A 4217 063 BTU h maximum 1 400 W 200 240 V CA 50 60 Hz courant maximum en entr e 8 6 A 5 724 BTU h maximum Le courant d appel initial ne peut pas d passer 55 A pic Le courant d appel secondaire ne peut pas d passer 35 A pic Guide de mise en route du syst me 25 Pile par carte syst me Pile du syst me Batterie RAID en option Pile bouton au lithium ion CR 2032 G V Pack 3 7 V au lithium ion Caract ristiques physiques Hauteur Largeur Profondeur Poids configuration maximale Poids vide 8 76 cm 3 45 po 44 8 cm 17 6 po 79 cm 31 1 po 42 kg 92 61 lb 16 5 kg 36 38 lb Caract ristiques environnementales REMARQUE Pour plus d informations concernant les mesures d exploitation li es des configurations sp cifiques voir www dell com environmental_datasheets Temp rature En fonctionnement En entreposage Humidit rela
26. e syst me Type de processeur Quatre processeurs AMD Opteron s rie 6100 Ou bien quatre processeurs AMD Opteron s rie 6200 Ou quatre processeurs AMD Opteron 6300 Series Bus d extension par carte syst me Type de bus Logements d extension PCIe Carte PCIe fille M moire par carte systeme PCI Express 2 me g n ration Un x16 compact MD1 longueur maximale de 12 18 cm Deux x16 compact MD2 longueur maximale de 16 95 cm Un x16 mezzanine Architecture Supports de barrettes de m moire Capacit s des barrettes de m moire 32 barrettes RDIMM ou UDIMM DDR3 1 066 1 333 1 600 MHz 32 supports de barrettes DIMM DDR3 2 Go 4 Go 8 Go 16 Go ou 32 Go RAM minimale 64 Go RAM maximale 1024 Go Lecteurs Disques durs Jusqu douze lecteurs SAS SAT 3 5 pouces rempla ables chaud ou jusqu vingt quatre lecteurs SAS SATA SSD 2 5 pouces rempla ables chaud REMARQUE Les disques durs SAS sont pris en charge par une carte suppl mentaire Guide de mise en route du syst me 24 Connecteurs par carte syst me Arri re Carte d interface r seau S rie USB Vid o Port de gestion Connecteur iPass Interne Support Micro SD Deux RJ 45 Ethernet 10 100 1 000 Mbit s DTE 9 broches compatible 16550 Deux connecteurs 4 broches compatibles USB 2 0 VGA D Sub 15 broches Port Ethernet d di pour l acc s la gestion distanc
27. e two chassis stabilizer shipping brackets optional are in place Getting Started With Your System 4 Figure 2 Installing the Chassis Stabilizer Shipping Brackets Back View VARA REMO 7 SNA 6 Slide the system into the rack 7 Tighten the thumbscrews to secure the ears of the system to the front of the rack flanges Figure 3 Installing the Chassis onto the Rack Back View Front View Getting Started With Your System 5 Optional Connecting the Keyboard Mouse and Monitor Figure 4 Optional Connecting the Keyboard Mouse and Monitor Connect the keyboard mouse and monitor optional The connectors on the back of your system have icons indicating which cable to plug into each connector Be sure to tighten the screws if any on the monitor s cable connector Getting Started With Your System 6 Connecting the Power Cable s Figure 5 Connecting the Power Cable gt UT Z AR S Connect the system s power cable s to the system and if a monitor is used connect the monitor s power cable to the monitor Plug the other end of the power cables into a grounded electrical outlet or a separate power source such as an uninterrupted power supply or a power distribution unit Getting Started With Your System 7 Turning on the System Figure 6 Pressing the Power Button on the Front of the System and the Monitor 1
28. er la souris et le moniteur facultatif Aidez vous des ic nes des connecteurs situ es l arri re du syst me pour savoir o ins rer chaque c ble N oubliez pas de serrer les vis situ es sur le connecteur du c ble du moniteur s il en est quip Guide de mise en route du syst me 20 Branchement du ou des c bles d alimentation Figure 5 Connexion du c ble d alimentation DT of Ni Y h Connectez le ou les c bles d alimentation au syst me et si vous utilisez un moniteur connectez son c ble d alimentation Branchez ensuite l autre extr mit des c bles d alimentation sur une prise de courant mise la terre ou sur une source d alimentation autonome onduleur ou unit de distribution de l alimentation Guide de mise en route du syst me 21 Mise sous tension du syst me Figure 6 Appui sur le bouton d alimentation l avant du syst me et du moniteur TE Appuyez sur le s bouton s d alimentation l avant ou l arri re du syst me et du moniteur Les indicateurs d alimentation situ s l avant devraient s allumer Guide de mise en route du syst me 22 74 REMARQUE les rails peuvent aussi bien tre utilis s dans un rack trous carr s l ment 1 dans la figure ci dessous que dans un rack trous ronds l ment 2 dans la figure ci dessous Finalisation de l installation du syst me d exploitation
29. limentaci n en el monitor variar seg n los diferentes modelos de monitor Configuraci n del sistema operativo Para instalar un sistema operativo por primera vez consulte la documentaci n de instalaci n y configuraci n que se entrega con el sistema operativo Aseg rese de que el sistema operativo est instalado antes de instalar hardware o software no adquirido con el sistema 4 NOTA Para obtener la informaci n m s reciente sobre los sistemas operativos compatibles visite dell com ossupport Otra informaci n til que puede necesitar A AVISO Consulte la informaci n sobre normativas y seguridad suministrada con el sistema La informaci n sobre la garant a puede estar incluida en este documento o constar en un documento aparte En el Manual del propietario del hardware se proporciona informaci n sobre las caracter sticas del sistema y se describe c mo solucionar problemas del sistema e instalar o reemplazar componentes del sistema Este documento est disponible en dell com support manuals En la documentaci n de la aplicaci n de administraci n de sistemas Dell se proporciona informaci n sobre c mo instalar y utilizar el software de administraci n de sistemas Este documento est disponible en l nea en dell com support manuals K NOTA Siempre compruebe si hay actualizaciones en dell com support manuals y lea primero las actualizaciones ya que a menudo esta informaci n reemplaza la de otros documentos
30. ot swappable SAS SATA SSD drives NOTE SAS hard drives are supported by add on card Getting Started With Your System 11 Connectors Per System Board Back NIC Serial USB Video Management port iPass connector Internal Micro SD socket Two RJ 45 10 100 1000 Mbps Ethernet 9 pin DTE 16550 compatible Two 4 pin USB 2 0 compliant 15 pin D Sub VGA Dedicated Ethernet port for remote management access Connect to external PCIE devices or a PCIE bus extender port SD riser card memory socket Video Per System Board Video type Video memory On board AST2050 video controller 8 MB Power AC power supply per power supply Wattage Voltage Heat dissipation Wattage Voltage Heat dissipation Maximum inrush current Getting Started With Your System 1023 W low line 1100 W high line 100 240 VAC 50 60 Hz maximum input current 12 0 Amps 4217 063 BTU hr maximum 1400 W 200 240 VAC 50 60 Hz maximum input current 8 6 Amps 5724 BTU hr maximum Initial In rush Current cannot exceed 55 Amps peak Secondary In rush Current cannot exceed 35 Amps peak Battery per system board System battery CR 2032 3 0 V lithium ion coin cell RAID battery optional 3 7 V lithium ion battery pack Physical Height 8 76 cm 3 45 in Width 44 8 cm 17 6 in Depth 79 0 cm 31 1 in Weight maximum 42 kg 92 61 Ib configuration Weight empty 16 5 kg 36 38 lb
31. pcional conexi n del teclado el mouse y el monitor Conecte el teclado el rat n y el monitor opcional Los conectores de la parte posterior del sistema incluyen iconos que indican qu cable debe enchufarse en cada conector Aseg rese de apretar los tornillos si los hay del conector del cable del monitor Procedimientos iniciales con el sistema 49 Conexi n de los cables de alimentaci n Ilustraci n 5 Conexi n del cable de alimentaci n 7 Le EON A JA Te R jj T Conecte los cables de alimentaci n al sistema y si se utiliza un monitor conecte el cable de alimentaci n correspondiente al monitor Conecte el otro extremo de los cables de alimentaci n a una toma el ctrica con conexi n a tierra o a otra fuente de energia como por ejemplo un sistema de alimentaci n ininterrumpida o una unidad de distribuci n de alimentaci n Procedimientos iniciales con el sistema 50 Encendido del sistema Ilustraci n 6 C mo presionar el bot n de alimentaci n en la parte anterior del sistema y el monitor Ilustraci n 7 C mo presionar el bot n de alimentaci n en la parte posterior del sistema Presione el bot n de encendido de la parte anterior o posterior del sistema y el monitor Deben encenderse los indicadores de alimentaci n en la parte anterior Procedimientos iniciales con el sistema 51 Es NOTA El color del indicador de a
32. rprise Linux s o marcas comerciais registradas da Red Hat Inc nos Estados Unidos e ou em outros pa ses Novell uma marca comercial registrada e SUSETM uma marca registrada da Novell Inc nos Estados Unidos e em outros pa ses Citrix e XenServer s o marcas registradas ou marcas comerciais da Citrix Systems Inc nos Estados Unidos e ou em outros pa ses VMware uma marca comercial registrada da VMWare Inc nos Estados Unidos ou em outros pa ses Outras marcas e nomes comerciais podem ser usados nesta publica o como refer ncia s entidades que reivindicam essas marcas e nomes ou a seus produtos A Dell Inc renuncia ao direito de qualquer participa o em nomes e marcas comerciais que n o sejam de sua propriedade Modelo de regulamenta o B05S Setembro de 2013 N P 6HNH8 Rev A04 A AVISO Local de acesso restrito Este servidor destina se a instala o apenas em locais de acesso restrito conforme definido na cl usula 1 2 7 3 da IEC 60950 1 2001 segundo a qual as duas condi es a seguir se aplicam e O acesso pode ser obtido apenas por profissionais de manuten o ou usu rios orientados sobre os motivos das restri es aplicadas ao local e sobre todas as precau es que devem ser adotadas e O acesso dever ser feito com o uso de uma ferramenta ou de uma trava com chave ou outros dispositivos de seguran a sendo controlado pela autoridade respons vel pelo local Instala o e configura
33. sion d onde carr e de 22 G avec un changement de vitesse de 508 cm s 200 po s De 16 3 048 m 50 10 000 pieds REMARQUE pour les altitudes sup rieures 900 m tres 2 950 pieds la temp rature maximale de fonctionnement est r duite de 0 55 C 1 F tous les 168 m tres 550 pieds De 16 10 600 m 50 35 000 pieds G2 ou inf rieure selon la norme ISA S71 04 1985 Guide de mise en route du syst me 27 Guide de mise en route du syst me 28 Dell PowerEdge C6145 Introdu o ao Uso do Sistema Notas Avisos e Advert ncias Es NOTA Uma NOTA fornece informa es importantes para ajudar voc a aproveitar melhor os recursos do computador A AVISO Um AVISO indica um potencial de danos ao hardware ou a perda de dados se as instru es n o forem seguidas AN ADVERT NCIA Uma ADVERT NCIA indica um potencial de danos propriedade risco de les es corporais ou mesmo risco de vida As informa es contidas neste documento est o sujeitas a altera es sem aviso pr vio O 2013 Dell Inc Todos os direitos reservados Qualquer forma de reprodu o deste material sem a permiss o por escrito da Dell Inc expressamente proibida Marcas comerciais usadas neste texto Dell o logotipo da DELL e PowerEdge s o marcas comerciais da Dell Inc AMD uma marca comercial registrada e AMD OpteronTM uma marca comercial da Advanced Micro Devices Inc Red Hat Enterprise Linux e Ente
34. tallation des rails sans outils A gt gt AVERTISSEMENT demandez toujours de l aide avant de soulever le syst me N essayez pas de le soulever seul car vous risqueriez de vous blesser AVERTISSEMENT le syst me n est fix ni au rack ni aux rails Vous devez le soutenir correctement au cours de l installation et du retrait pour viter de l endommager ou de vous blesser AVERTISSEMENT afin d viter un ventuel choc lectrique assurez vous que vous disposez d un troisi me conducteur de mise la terre pour l installation du rack L quipement du rack doit assurer une ventilation suffisante pour bien refroidir le syst me PR CAUTION lorsque vous installez des rails dans un rack trous carr s v rifiez que les taquets de fixation t te carr e glissent bien dans les trous carr s Guide de mise en route du syst me 17 1 Tirez sur les boutons d ouverture du loquet situ s au milieu de l unit d extr mit pour ouvrir les loquets des rails 2 Alignez les extr mit s des rails avec les montants verticaux du rack de mani re ins rer les chevilles l une en bas et l autre en haut Faites glisser l extr mit arri re des rails coulissants jusqu ce que les loquets de verrouillage s enclenchent REMARQUE les rails peuvent aussi bien tre utilis s dans un rack 4 trous carr s l ment 1 dans la figure ci dessous que dans un rack trous ronds l ment 2 dans la figure ci dessous
35. tive En fonctionnement En entreposage Guide de mise en route du syst me De 10 35 C 50 95 F avec un gradient thermique maximal de 10 C par heure REMARQUE pour les altitudes sup rieures 900 m tres 2 950 pieds la temp rature maximale de fonctionnement est r duite de 0 55 C 1 F tous les 168 m tres 550 pieds REMARQUE pour les processeurs AMD 6180SE 140W la temp rature maximale de fonctionnement est de 30 C 86 F De 40 65 C 40 149 F avec un gradient thermique maximal de 20 C par heure De 20 80 sans condensation avec un gradient d humidit maximal de 10 par heure De 5 95 sans condensation 26 Tol rance maximale aux vibrations En fonctionnement En entreposage Choc maximal En fonctionnement En entreposage Altitude En fonctionnement En entreposage Contaminants en suspension dans l air Classe 0 26 Grms avec un balayage de 5 350 Hz 1 88 Grms avec un balayage de 10 500 Hz pendant 15 minutes Une impulsion de choc de 31 G une impulsion de chaque c t du syst me pendant un maximum de 2 6 ms sur l axe z positif en position de fonctionnement Six chocs cons cutifs de 71 G pendant un maximum de 2 ms en positif et n gatif sur les axes x y et z une impulsion de chaque c t du syst me Six chocs cons cutifs sur les axes x y et z en positif et n gatif une impulsion de chaque c t du syst me d impul
36. una marca comercial o una marca comercial registrada de VMWare Inc en los Estados Unidos o en otros pa ses Otras marcas y otros nombres comerciales pueden utilizarse en esta publicaci n para hacer referencia a las entidades que los poseen o a sus productos Dell Inc renuncia a cualquier inter s sobre la propiedad de marcas y nombres comerciales que no sean los suyos Modelo reglamentario B05S Septiembre de 2013 N P 6HNH8 Rev A04 A PRECAUCI N rea de acceso restringido Este servidor est dise ado nicamente para su instalaci n en reas de acceso restringido tal como se define en la cl usula 1 2 7 3 de la IEC 60950 1 2001 donde se aplican las dos condiciones siguientes S lo pueden tener acceso personas de asistencia t cnica o usuarios a los que se haya informado de las razones de las restricciones que se aplican al lugar y acerca de las precauciones que deban tenerse en cuenta El acceso se realiza mediante un dispositivo o una cerradura y llave u otros medios de seguridad y est controlado por la autoridad responsable de esta rea Instalaci n y configuraci n A AVISO Antes de realizar el procedimiento siguiente consulte y siga las instrucciones de seguridad incluidas con el sistema Desembalaje del sistema Desembale el sistema e identifique cada elemento Instalaci n de la soluci n de rieles de montaje sin herramientas A gt iB AVISO Siempre que necesite levantar el sistema pida l
Download Pdf Manuals
Related Search
Related Contents
RIDGID ZRR86008K Use and Care Manual TP Modulation d`amplitude Método de ajuste del desviador de cambios trasero Juntatec_Ficha-Tecnica_ES QUARTIERS Philips AZ1846 MP3 CD Soundmachine LIBRETTO ISTRUZIONI - Mukka Express .::. l`arte del cappuccino Notice - France Arrosage TWO/TWD vers. - Arizona AARP Tax-Aide Circuit for disabling an address masking control signal using OR Copyright © All rights reserved.